Summer AIAD at Los Alamos National Laboratory (LANL) [Slides]
Abstract not provided.
SEARCH · Search NASA
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Abstract not provided.
Presenters identified the following statuses of the light-element standards: Extension of N-N scattering analysis to 200 MeV will likely come in time for ENDF/B VIII.1 and new data are to be added even in the energy range up to 100 MeV; for n- 3 He, a more recent 4 He R-matrix analysis from which updated n+ 3 He cross sections could be obtained for ENDF/B VIII.1; for n- 6 Li, more work is required to get a reasonable fit to all data up to E n = 8 MeV. Of particular concern are the t+ 4 He scattering data at E t > 14 MeV. For n- 10 B, new work on the 11 B system has not yet been started and there is much new data to add for n+ 10 B reactions, and maybe also for α + 7 Li reactions. The proliferation of excited-state channels will limit the upper neutron energy of the analysis to a few MeV. For n- 12 C, new elastic and inelastic scattering data from Vanhoy support the results of the present analysis. More work is needed to extend the fit successfully above 6.5 MeV.
Abstract not provided.
This presentation was requested by DOE EM and EM-LA to understand the facility status of 03-0016, Ion Beam in order for DOE EM to prepare estimates and demolish the facility. The slides detail the process and status with before and after images.
Abstract not provided.
We need such big computers because without testing, we don't understand the health of the AGING stockpile. Our big computers store a wealth of test data. We model weapons as they were tested and see if we can match the results to validate models, and we then use validated models along with dismantlement information on aging to certify the stockpile. Sometimes the results of tests can’t be explained well, so even that part requires massive computations, but applying the model to future use is an astonishing amount of computing.
We are dedicated to addressing complex national security issues and the world’s most difficult challenges.
The two example scenarios described in the report are built around either boundary condition modification or pump and treat. Boundary condition modification focuses primarily on aggressively reducing the driving force of water that is moving Cr(VI) through the subsurface system at LANL, carefully monitoring hydrologic responses, and quantifying natural attenuation rates in key portions of the plume. This scenario would provide a measurable impact on subsurface hydrology using relatively low-cost methods and emphasizing data collection to support the CME process. The second scenario focuses on active removal of Cr(VI) using pump and treat combined with a variety of data collection activities. This scenario would also include some boundary condition modification and would provide more timely impacts in the mid-plume area. However, it is substantially more costly and faces more significant logistical, regulatory, and data interpretation hurdles. Because of these issues and challenges, the pump and treat based scenario would be appropriate primarily for the case in which Cr(VI) removal and more rapid near-term impacts in the mid-plume are considered to be high, overriding priorities. We recommend careful consideration of the advantages and disadvantages of different “combined remedy” IM scenarios and urge the LANL team and its regulators and stakeholders to assemble and select a scenario that is implementable and that provides useful and actionable data to inform and support the CME. Both of the example scenarios presented meet these criteria.
ARCHIMEDES is a process in which experiment optimization is performed utilizing sensitivities from MCNP and Whisper. A Gaussian process (GP) optimization is used to guide criticality experiment design. An example of this process is shown for LANL PF-4 plutonium casting.
Abstract not provided.
Abstract not provided.
The Net-Zero (NZ) Decarbonization Roadmap builds upon LANL’s storied & innovative energy-related history. It also builds upon existing LANL planning frameworks. The Net Zero Roadmap Framework defines a ‘whole of LANL’ approach for meeting overarching, builds upon existing planning efforts, identifies and prioritizes critical path actions LANL can adapt to meet net & real-time clean electricity targets, and identifies key technological challenges in achieving targets.
Proton radiography at LANL (pRad) takes advantage of the high flux, high proton energy, and flexible timing structure of LANSCE's 800-MeV proton beam to visualize dense, dynamic systems under extreme strain. With recent needs identified for the development of the W93, the pRad team has been actively searching for ways to increase the facility's radiographic capabilities. Recently, we discovered that utilizing two magnetic lenses (one upstream and one downstream of the object), and specific combinations of collimator choices within the two lenses, that the signal-to-noise ratio was improved by more than a factor of two. However, we did not fully understand the mechanism, and found that results did not match forward modeling predictions. This work specifically sought to implement an engineering solution to solve this problem, through the development of an actuated collimator that reduced the time required to swap collimator settings from a typical 4-8 hours, to less than 30 seconds. This allowed, in combination with a unique multi-material, multi-resolution stepwedge, to acquire an unprecedently enormous dataset, with in total 24 collimation combinations, and multiple diffuser settings and pulse patterns, equivalent to almost a full run cycle's worth of data in a few days. This massive dataset is currently being harnessed to make a fully-predictive, ultra-fast Python-based model of the system, to dial in specific settings for any future experiments that fully optimize that radiographic sensitivity to the material of interest.
Abstract not provided.
Abstract not provided.
Abstract not provided.