Search NASA⌕ Search

SEARCH · Search NASA

Results for “Linearization error”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 721 records · Page 40

Convergence of Weak-SINDy Surrogate Models

In this paper, we give an in-depth error analysis for surrogate models generated by a variant of the Sparse Identification of Nonlinear Dynamics (SINDy) method. We start with an overview of a variety of nonlinear system identification techniques, namely SINDy, weak-SINDy, and the occupation kernel method. Under the assumption that the dynamics are a finite linear combination of a set of basis functions, these methods establish a linear system to recover coefficients. We illuminate the structural similarities between these techniques and establish a projection property for the weak-SINDy technique. Following the overview, we analyze the error of surrogate models generated by a simplified version of weak-SINDy. In particular, under the assumption of boundedness of a composition operator given by the solution, we show that (i) the surrogate dynamics converges towards the true dynamics and (ii) the solution of the surrogate model is reasonably close to the true solution. Finally, as an application, we discuss the use of a combination of weak-SINDy surrogate modeling and proper orthogonal decomposition (POD) to build a surrogate model for partial differential equations (PDEs).

97 MATHEMATICS AND COMPUTING↗

SU-F-BRD-05: Robustness of Dose Painting by Numbers in Proton Therapy

Purpose: Proton range uncertainties may cause important dose perturbations within the target volume, especially when steep dose gradients are present as in dose painting. The aim of this study is to assess the robustness against setup and range errors for high heterogeneous dose prescriptions (i.e., dose painting by numbers), delivered by proton pencil beam scanning. Methods: An automatic workflow, based on MATLAB functions, was implemented through scripting in RayStation (RaySearch Laboratories). It performs a gradient-based segmentation of the dose painting volume from 18FDG-PET images (GTVPET), and calculates the dose prescription as a linear function of the FDG-uptake value on each voxel. The workflow was applied to two patients with head and neck cancer. Robustness against setup and range errors of the conventional PTV margin strategy (prescription dilated by 2.5 mm) versus CTV-based (minimax) robust optimization (2.5 mm setup, 3% range error) was assessed by comparing the prescription with the planned dose for a set of error scenarios. Results: In order to ensure dose coverage above 95% of the prescribed dose in more than 95% of the GTVPET voxels while compensating for the uncertainties, the plans with a PTV generated a high overdose. For the nominal case, up to 35% of the GTVPET received doses 5% beyond prescription. For the worst of the evaluated error scenarios, the volume with 5% overdose increased to 50%. In contrast, for CTV-based plans this 5% overdose was present only in a small fraction of the GTVPET, which ranged from 7% in the nominal case to 15% in the worst of the evaluated scenarios. Conclusion: The use of a PTV leads to non-robust dose distributions with excessive overdose in the painted volume. In contrast, robust optimization yields robust dose distributions with limited overdose. RaySearch Laboratories is sincerely acknowledged for providing us with RayStation treatment planning system and for the support provided.

60 APPLIED LIFE SCIENCES↗

Linearly independent pure-state decomposition and quantum state discrimination

We put the pure-state decomposition mathematical property of a mixed state to a physical test. We present a protocol for preparing two known nonorthogonal quantum states with well-defined a priori probabilities. Hence we characterize all the possible decompositions of a rank-two mixed state by means of the complex overlap between the two involved states. The physical test proposes a scheme for quantum state recognition of one of the two linearly independent states that arise from the decomposition. We find that the two states associated with the balanced pure-state decomposition have the smaller overlap modulus and therefore the smallest probability of being discriminated conclusively, while in the nonconclusive process they have the highest probability of having an error. In addition, we design an experimental scheme that allows discriminating conclusively and optimally two nonorthogonal states prepared with different a priori probabilities. Thus we propose a physical implementation for this linearly independent pure-state decomposition and state discrimination test by using twin photons generated in the process of spontaneous parametric down-conversion. The information state is encoded in a one-photon polarization state, whereas the second single photon is used for heralded detection.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Theory and numerics of subspace approximation of eigenvalue problems

Large-scale eigenvalue problems arise in various fields of science and engineering and demand computationally efficient solutions. In this study, we investigate the subspace approximation for parametric linear eigenvalue problems, aiming to mitigate the computational burden associated with high-fidelity systems. Furthermore, we provide general error estimates under non-simple eigenvalue conditions, establishing some theoretical foundations for understanding the convergence behavior of subspace approximations. Numerical examples, including problems with one-dimensional to three-dimensional spatial domain and one-dimensional to two-dimensional parameter domain, are presented to demonstrate the efficacy of reduced basis method in handling parametric variations in boundary conditions and coefficient fields to achieve significant computational savings while maintaining high accuracy, making them promising tools for practical applications in large-scale eigenvalue computations.

Eigenvalue problems↗

Multi-plane moment-of-fluid interface reconstruction in 3D

Moment-of-fluid (MOF) methods for interface reconstruction approximate the region occupied by material in each mesh element only through reference to its geometric moments. Here, we present a 3D MOF method that represents the material (POM) in each cell as the convex intersection of the cell and multiple half-spaces, each selected to minimize the least-squares error between computed moments of the approximated material and provided reference moments. This optimization problem is highly non-linear and non-convex, making the numerical result very sensitive to the initial guess. To create an effective initial guess in each cell, we construct an ellipsoid from 0th–2nd order reference moments such that its shape corresponds with that of the POM. Within this ellipsoid we inscribe a polyhedron, and initialize the minimization problem with the half-spaces defined by each of its faces. The inscribed polyhedron has minimally 4 faces, and using up to 3rd order moments permits optimization over up to 20 unknown values. We therefore define MOF methods that utilize 4, 5, or 6 half-spaces, correspondingly initialized with the faces of a single inscribed tetrahedron, triangular prism, or hexahedron. Stability of the non-linear optimization is further improved with a prepossessing step that normalizes the reference moments according to the axes of the reference ellipsoid. Using this approach, the non-linear least-squares solver reliably converges to a near-global minimum from a single initial guess. We demonstrate accuracy and robustness using single-cell and multi-cell examples over a wide spectrum of geometry. In particular, we demonstrate our ability to exactly reproduce several important and complex features defined by up to four half-spaces, such as corners, filaments, filament tips, and embedded material in the cell.

3D interface reconstruction↗

Simplified calculation of the area specific impedance for solid-state battery design

Simplified algebraic area specific impedance (ASI) correlations have been developed for solid-state composite battery electrodes made of a single ion conducting electrolyte, conductive additive, and intercalation active material. Two ASI expressions were developed, one for short times ( i.e. , pulsed power operation) and another for the pseudo steady state operation (i.e., sustained discharge for energy estimation). A full electrochemical model based on porous electrode theory was developed to examine the accuracy of the simplified ASI expressions. The simplified expressions agree favorably with full model results over a wide range of parameters (i.e. , electrode thicknesses, electrolyte conductivities, solid-state diffusion coefficients, specific surface areas, etc.) and conditions (i.e. , C-rates, states of charge, and pulse times). Under most conditions, the error between the full model and the correlations is well below 7 %. Higher errors were observed for the pseudo steady state expression at high/ low states of charge where the assumption of uniform reaction distributions loses validity. Here, the short time ASI has higher error at low states of charge due to the nonlinearity of the open circuit voltage equation, which is assumed linear in the formulation of the simplified algebraic expression.

25 ENERGY STORAGE↗

Representing Grasslands Using Dynamic Prognostic Phenology Based on Biological Growth Stages: Part 2. Carbon Cycling

Grasslands are one of the most widely distributed and abundant vegetation types globally, and land surface models struggle to accurately simulate grassland carbon dioxide, energy, and water fluxes. Here we hypothesize that this is due to land surface models having difficulties in reproducing grassland phenology, in particular in response to the seasonal and interannual variability of precipitation. Using leaf area index (LAI), net primary productivity, and flux data at 55 sites spanning climate zones, the aim of this study is to evaluate a novel prognostic phenology model (Simple Biosphere Model, SiB4) while simultaneously illustrating grassland relationships across precipitation gradients. Evaluating from 2000 to 2014, SiB4 predicts daily LAI, carbon, and energy fluxes with root-mean-square errors < 15% and individual biases <10%; however, not including management likely reduces its performance. Grassland mean annual LAI increases linearly with mean annual precipitation, with both SiB4 and the Moderate Resolution Imaging Spectroradiometer (MODIS) showing a 0.13 increase in LAI per 100-mm increase in precipitation. Both gross primary production and ecosystem respiration increase with growing season length by ~8.5 g C m -2 per day, with SiB4 and Fluxnet estimates within 18%. Despite differences in mean annual precipitation and growing season length, all grassland sites shift to seasonal carbon sinks one month prior to peak uptake. During a U.S. drought, MODIS and SiB4 had nearly identical LAI responses, and the LAI change due to drought was less than the LAI change across the precipitation gradient, indicating that grassland drought response is not as strong as the overlying climate response.

54 ENVIRONMENTAL SCIENCES↗

Magnetohydrodynamic interference with the edge pedestal motional Stark effect diagnostic on DIII-D

Accurate measurement of internal magnetic field direction using motional Stark effect (MSE) polarimetry in the edge pedestal is desired for nearly all tokamak scenario work. A newly installed 500 kHz 32-channel digitizer on the MSE diagnostic of DIII-D allows full spectral information of the polarimeter signal to be recovered for the first time. Fourier analysis of this data has revealed magnetohydrodynamic (MHD) fluctuations in the plasma edge pedestal at {rho}{>=} 0.92. By correlating edge localized mode fluctuations seen on lock-in amplifier outputs with MSE spectrograms, it has been shown that edge pedestal tearing mode fluctuations cause interference with MSE second harmonic instrument frequencies. This interference results in unrecoverable errors in the real-time polarization angle measurement that are more than an order of magnitude larger than typical polarimeter uncertainties. These errors can cause as much as a 38% difference in local q. By using a redundant measure of the linear polarization found at the fourth harmonic photo-elastic modulator (PEM) frequency, MHD interference can be avoided. However, because of poorer signal-to-noise the fourth harmonic signal computed polarization angle shows no improvement over the MHD polluted second harmonics. MHD interference could be avoided in future edge pedestal tokamak polarimeters by utilizing PEMs with higher fundamental frequencies and a greater separation between their frequencies.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Total variation-based neutron computed tomography

We perform the neutron computed tomography reconstruction problem via an inverse problem formulation with a total variation penalty. In the case of highly under-resolved angular measurements, the total variation penalty suppresses high-frequency artifacts which appear in filtered back projections. Here, in order to efficiently compute solutions for this problem, we implement a variation of the split Bregman algorithm; due to the error-forgetting nature of the algorithm, the computational cost of updating can be significantly reduced via very inexact approximate linear solvers. We present the effectiveness of the algorithm in the significantly low-angular sampling case using synthetic test problems as well as data obtained from a high flux neutron source. Finally, the algorithm removes artifacts and can even roughly capture small features when an extremely low number of angles are used.

97 MATHEMATICS AND COMPUTING↗

SIMPLE FIT OF DATA RELATING SUPERMASSIVE BLACK HOLE MASS TO GALAXY PITCH ANGLE

Seigar et al. have recently demonstrated a new, tight correlation between galactic central supermassive black hole (BH) mass and the pitch angle of the spiral arm in disk galaxies which they attribute to other indirect correlations. They fit a double power law, governed by five parameters, to the BH mass as a function of pitch. Noting the features of their fitted curve, we show that a simple linear proportion of the BH mass to the cotangent of the pitch angle can obtain the same fit, within error. Such a direct, elegant fit may help shed light on the nature of the correlation.

79 ASTRONOMY AND ASTROPHYSICS↗

EXPLORING THE VARIABLE SKY WITH LINEAR. III. CLASSIFICATION OF PERIODIC LIGHT CURVES

We describe the construction of a highly reliable sample of ∼7000 optically faint periodic variable stars with light curves obtained by the asteroid survey LINEAR across 10,000 deg{sup 2} of the northern sky. The majority of these variables have not been cataloged yet. The sample flux limit is several magnitudes fainter than most other wide-angle surveys; the photometric errors range from ∼0.03 mag at r = 15 to ∼0.20 mag at r = 18. Light curves include on average 250 data points, collected over about a decade. Using Sloan Digital Sky Survey (SDSS) based photometric recalibration of the LINEAR data for about 25 million objects, we selected ∼200,000 most probable candidate variables with r < 17 and visually confirmed and classified ∼7000 periodic variables using phased light curves. The reliability and uniformity of visual classification across eight human classifiers was calibrated and tested using a catalog of variable stars from the SDSS Stripe 82 region and verified using an unsupervised machine learning approach. The resulting sample of periodic LINEAR variables is dominated by 3900 RR Lyrae stars and 2700 eclipsing binary stars of all subtypes and includes small fractions of relatively rare populations such as asymptotic giant branch stars and SX Phoenicis stars. We discuss the distribution of these mostly uncataloged variables in various diagrams constructed with optical-to-infrared SDSS, Two Micron All Sky Survey, and Wide-field Infrared Survey Explorer photometry, and with LINEAR light-curve features. We find that the combination of light-curve features and colors enables classification schemes much more powerful than when colors or light curves are each used separately. An interesting side result is a robust and precise quantitative description of a strong correlation between the light-curve period and color/spectral type for close and contact eclipsing binary stars (β Lyrae and W UMa): as the color-based spectral type varies from K4 to F5, the median period increases from 5.9 hr to 8.8 hr. These large samples of robustly classified variable stars will enable detailed statistical studies of the Galactic structure and physics of binary and other stars and we make these samples publicly available.

79 ASTRONOMY AND ASTROPHYSICS↗

Measuring infrared surface brightness fluctuation distances with HST WFC3: Calibration and advice

We present new calibrations of the near-infrared (near-IR) surface brightness fluctuation (SBF) distance method for the F110W (J{sub 110}) and F160W (H{sub 160}) bandpasses of the Wide Field Camera 3 Infrared Channel (WFC3/IR) on the Hubble Space Telescope. The calibrations are based on data for 16 early-type galaxies in the Virgo and Fornax clusters observed with WFC3/IR and are provided as functions of both the optical (g{sub 475}−z{sub 850}) and near-infrared (J{sub 110}−H{sub 160}) colors. The scatter about the linear calibration relations for the luminous red galaxies in the sample is approximately 0.10 mag, corresponding to a statistical error of 5% in distance. Our results imply that the distance to any suitably bright elliptical galaxy can be measured with this precision out to about 80 Mpc in a single-orbit observation with WFC3/IR, making this a remarkably powerful instrument for extragalactic distances. The calibration sample also includes much bluer and lower-luminosity galaxies than previously used for IR SBF studies, revealing interesting population differences that cause the calibration scatter to increase for dwarf galaxies. Comparisons with single-burst population models show that as expected, the redder early-type galaxies contain old, metal-rich populations, while the bluer dwarf ellipticals contain a wider range of ages and lower metallicities than their more massive counterparts. Radial SBF gradients reveal that IR color gradients are largely an age effect; the bluer dwarfs typically have their youngest populations near their centers, while the redder giant ellipticals show only weak trends and in the opposite sense. Because of the population variations among bluer galaxies, distance measurements in the near-IR are best limited to red early-type galaxies. We conclude with some practical guidelines for using WFC3/IR to measure reliable SBF distances.

79 ASTRONOMY AND ASTROPHYSICS↗

The matrix product approximation for the dynamic cavity method

Stochastic dynamics of classical degrees of freedom, defined on vertices of locally tree-like graphs, can be studied in the framework of the dynamic cavity method which is exact for tree graphs. Such models correspond for example to spin-glass systems, Boolean networks, neural networks, and other technical, biological, and social networks. The central objects in the cavity method are edge messages—conditional probabilities of two vertex variable trajectories. In this paper, we discuss a rather pedagogical derivation for the dynamic cavity method, give a detailed account of the novel matrix product edge message (MPEM) algorithm for the solution of the dynamic cavity equation as introduced, and present optimizations and extensions. Matrix product approximations of the edge messages are constructed recursively in an iteration over time. Computation costs and precision can be tuned by controlling the matrix dimensions of the MPEM in truncations. Without truncations, the dynamics is exact. Data for Glauber–Ising dynamics shows a linear growth of computation costs in time. In contrast to Monte Carlo simulations, the approach has a much better error scaling. Hence, it gives for example access to low probability events and decaying observables like temporal correlations. Here, we discuss optimized truncation schemes and an extension that allows to capture models which have a continuum time limit.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Experimental validation of a method characterizing bow tie filters in CT scanners using a real-time dose probe

Purpose: Beam-shaping or ''bow tie'' (BT) filters are used to spatially modulate the x-ray beam in a CT scanner, but the conventional method of step-and-shoot measurement to characterize a beam's profile is tedious and time-consuming. The theory for characterization of bow tie relative attenuation (COBRA) method, which relies on a real-time dosimeter to address the issues of conventional measurement techniques, was previously demonstrated using computer simulations. In this study, the feasibility of the COBRA theory is further validated experimentally through the employment of a prototype real-time radiation meter and a known BT filter. Methods: The COBRA method consisted of four basic steps: (1) The probe was placed at the edge of a scanner's field of view; (2) a real-time signal train was collected as the scanner's gantry rotated with the x-ray beam on; (3) the signal train, without a BT filter, was modeled using peak values measured in the signal train of step 2; and (4) the relative attenuation of the BT filter was estimated from filtered and unfiltered data sets. The prototype probe was first verified to have an isotropic and linear response to incident x-rays. The COBRA method was then tested on a dedicated breast CT scanner with a custom-designed BT filter and compared to the conventional step-and-shoot characterization of the BT filter. Using basis decomposition of dual energy signal data, the thickness of the filter was estimated and compared to the BT filter's manufacturing specifications. The COBRA method was also demonstrated with a clinical whole body CT scanner using the body BT filter. The relative attenuation was calculated at four discrete x-ray tube potentials and used to estimate the thickness of the BT filter. Results: The prototype probe was found to have a linear and isotropic response to x-rays. The relative attenuation produced from the COBRA method fell within the error of the relative attenuation measured with the step-and-shoot method. The BT filter thickness estimates resulting from the dual energy scans on the breast CT system were equivalent to the manufacturing specifications. The clinical CT evaluation produced data conceptually similar to previous computer simulations and plausible relative attenuation profiles were observed. Conclusions: The COBRA method is a fast and accurate method for BT filter characterization, which requires a simple experimental setup in a clinical environment. Because of the ease of data acquisition, multienergy scans can be acquired which allow characterization of the BT filter thickness.

60 APPLIED LIFE SCIENCES↗

Effect of reconstruction methods and x-ray tube current–time product on nodule detection in an anthropomorphic thorax phantom: A crossed-modality JAFROC observer study

Purpose: To evaluate nodule detection in an anthropomorphic chest phantom in computed tomography (CT) images reconstructed with adaptive iterative dose reduction 3D (AIDR{sup 3D}) and filtered back projection (FBP) over a range of tube current–time product (mAs). Methods: Two phantoms were used in this study: (i) an anthropomorphic chest phantom was loaded with spherical simulated nodules of 5, 8, 10, and 12 mm in diameter and +100, −630, and −800 Hounsfield units electron density; this would generate CT images for the observer study; (ii) a whole-body dosimetry verification phantom was used to ultimately estimate effective dose and risk according to the model of the BEIR VII committee. Both phantoms were scanned over a mAs range (10, 20, 30, and 40), while all other acquisition parameters remained constant. Images were reconstructed with both AIDR{sup 3D} and FBP. For the observer study, 34 normal cases (no nodules) and 34 abnormal cases (containing 1–3 nodules, mean 1.35 ± 0.54) were chosen. Eleven observers evaluated images from all mAs and reconstruction methods under the free-response paradigm. A crossed-modality jackknife alternative free-response operating characteristic (JAFROC) analysis method was developed for data analysis, averaging data over the two factors influencing nodule detection in this study: mAs and image reconstruction (AIDR{sup 3D} or FBP). A Bonferroni correction was applied and the threshold for declaring significance was set at 0.025 to maintain the overall probability of Type I error at α = 0.05. Contrast-to-noise (CNR) was also measured for all nodules and evaluated by a linear least squares analysis. Results: For random-reader fixed-case crossed-modality JAFROC analysis, there was no significant difference in nodule detection between AIDR{sup 3D} and FBP when data were averaged over mAs [F(1, 10) = 0.08, p = 0.789]. However, when data were averaged over reconstruction methods, a significant difference was seen between multiple pairs of mAs settings [F(3, 30) = 15.96, p < 0.001]. Measurements of effective dose and effective risk showed the expected linear dependence on mAs. Nodule CNR was statistically higher for simulated nodules on images reconstructed with AIDR{sup 3D} (p < 0.001). Conclusions: No significant difference in nodule detection performance was demonstrated between images reconstructed with FBP and AIDR{sup 3D}. mAs was found to influence nodule detection, though further work is required for dose optimization.

60 APPLIED LIFE SCIENCES↗

A Second-Order Time-Stepping Scheme for Simulating Ensembles of Parameterized Flow Problems

Abstract We consider settings for which one needs to perform multiple flow simulations based on the Navier–Stokes equations, each having different initial condition data, boundary condition data, forcing functions, and/or coefficients such as the viscosity. For such settings, we propose a second-order time accurate ensemble-based method that to simulate the whole set of solutions, requires, at each time step, the solution of only a single linear system with multiple right-hand-side vectors. Rigorous analyses are given proving the conditional stability and establishing error estimates for the proposed algorithm. Numerical experiments are provided that illustrate the analyses.

Mathematics↗

An efficient decoder for a linear distance quantum LDPC code

Recent developments have shown the existence of quantum low-density parity check (qLDPC) codes with constant rate and linear distance. A natural question concerns the efficient decodability of these codes. In this paper, we present a linear time decoder for the recent quantum Tanner codes construction of asymptotically good qLDPC codes, which can correct all errors of weight up to a constant fraction of the blocklength. Our decoder is an iterative algorithm which searches for corrections within constant-sized regions. At each step, the corrections are found by reducing a locally defined and efficiently computable cost function which serves as a proxy for the weight of the remaining error.

97 MATHEMATICS AND COMPUTING↗

Submicron multi-bunch BPM for CLIC

A common-mode free cavity BPM is currently under development at Fermilab within the ILC-CLIC collaboration. This monitor will be operated in a CLIC Main Linac multi-bunch regime, and needs to provide both, high spatial and time resolution. We present the design concept, numerical analysis, investigation on tolerances and error effects, as well as simulations on the signal response applying a multi-bunch stimulus. The proposed CERN linear collider (CLIC) requires a very precise measurement of beam trajectory to preserve the low emittance when transporting the beam through the Main Linac. An energy chirp within the bunch train will be applied to measure and minimize the dispersion effects, which require high resolution (in both, time and space) beam position monitors (BPM) along the beam-line. We propose a low-Q waveguide loaded TM{sub 110} dipole mode cavity as BPM, which is complemented by a TM{sub 010} monopole mode resonator of same resonant frequency for reference signal purposes. The design is based on a well known TM{sub 110} selective mode coupling idea.

43 PARTICLE ACCELERATORS↗