Search NASA⌕ Search

SEARCH · Search NASA

Results for “Liquid sampling”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 721 records · Page 40

Quench Detection for High-Temperature Superconductor Conductors Using Acoustic Thermometry

Detecting local heat-dissipating zones in high-temperature superconductor (HTS) magnets is a challenging task due to slow propagation of such zones in HTS conductors. For long conductor lengths, voltage-based methods may not provide a sufficient sensitivity or redundancy, and therefore nonvoltage-based detection alternatives are being sought. One of those is the recently proposed method of Eigen Frequency Thermometry (EFT), which is an active acoustic technique for a fast and nonintrusive detection of 'hot spots,' utilizing temperature dependence of the conductor elastic moduli. In this work, we demonstrate the efficiency of EFT for detecting localized heating in a 1.2-m-long sample of REBCO tape immersed in liquid nitrogen, and benchmark sensitivity of the acoustic detection with respect to voltage, hot spot temperature, and power dissipation in the conductor. Modifying the original technique for differential mode of operation enables a much improved sensitivity, and adds a hot spot localization capability. Furthermore, we adapt this technique to subscale coils wound with REBCO CORC conductor built in the framework of U.S. Magnet Development Program. A successful thermal-based detection of dissipation onset at the critical current for a two-layer canted CORC dipole assembly is discussed.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Analysis of TATB by uHPLC-DAD (V.2.2)

The following procedure describes the method for determining the purity of 1,3,5-triamino 2,4,6-trinitrobenzene (TATB) samples using a High-Performance Liquid Chromatography (HPLC) system fitted with a Diode Array Detector (DAD).

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Analysis of TATB by HPLC-DAD (V.1.4)

The following procedure describes the method for determining the purity of 1,3,5-triamino 2,4,6-trinitrobenzene (TATB) samples using a High-Performance Liquid Chromatography (HPLC) system fitted with a Diode Array Detector (DAD). This procedure is also applicable for the detection of some impurities present in TATB.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Electrical Insulation Paper and Its Physical Properties at Cryogenic Temperatures

Paper is widely used in various engineering applications due to its physical properties and ease of manufacture. As a result paper has been selected or designed as an electrical insulation material for parts and components in high voltage technology. In the current study we select a paper employed in conventional transformers as the electrical insulation material. The potential of this paper is investigated at cryogenic temperatures to determine its physical properties for high temperature superconducting power applications. Dielectric measurements were performed using impedance spectroscopy at a constant frequency. Dielectric breakdown tests were performed on samples at 77 K using a liquid nitrogen bath.

36 MATERIALS SCIENCE↗

A Multi-Sample Residual Resistivity Ratio System for High Quality Superconductor Measurements

For developing accelerator cavity materials, superconducting transition temperature (TC), transition width (ΔTC), and residual resistivity ratio (RRR), are useful parameters to correlate with SRF performance and fabrication processes of bulk, thin film, and novel materials. The RRR gauges the purity and structure of the superconductor based on the temperature dependence of electron scattering in the normal conducting state. Combining a four point probe delta pulse setup with a switch allows multiplexing of the electrical measurements to 32 samples per cooldown cycle. The samples are measured inside of an isothermal setup in a liquid helium (LHe) dewar. The isothermal setup is required for a quasistatic warmup of the samples through TC. This contribution details the current setup for collecting RRR and TC data, the current standard of throughput, measurement quality of the setup, and the improvements underway to increase the system’s resolution and ease of use.

Spradlin, J. K.↗

Photoelectron Spectroscopy under Ambient Pressure and Temperature Conditions

We describe the development and applications of novel instrumentation for photoemission spectroscopy of solid or liquid surfaces in the presence of gases under ambient conditions or pressure and temperature. The new instrument overcomes the strong scattering of electrons in gases by the use of an aperture close to the surface followed by a differentially-pumped electrostatic lens system. In addition to the scattering problem, experiments in the presence of condensed water or other liquids require the development of special sample holders to provide localized cooling. We discuss the first two generations of Ambient Pressure PhotoEmission Spectroscopy (APPES) instruments developed at synchrotron light sources (ALS in Berkeley and BESSY in Berlin), with special focus on the Berkeley instruments. Applications to environmental science and catalytic chemical research are illustrated in two examples.

36 MATERIALS SCIENCE↗

Prediction and Measurement of the Kinetics of Isothermal Crystallization and Devitrification of Mold Powder Slags

The rate and extent of formation of crystalline phases in the slag film that develops between the mold and the strand in steel continuous casting determine heat transfer and lubrication between them and therefore play crucial roles in shell integrity. In this work, a commercial mold powder for casting medium carbon (MC) thin steel slabs is selected for carrying out detailed comparisons between predicted and experimental results of the rates of isothermal crystallization and devitrification of liquid and glassy slag, respectively. Predictions are obtained with a kinetic model that combines the induction period (of Šimon and Kolman) and the Kissinger methods to evaluate time–temperature–transformation (TTT) diagrams for the devitrification and crystallization reactions associated with the peaks appearing in non-isothermal thermo-analysis traces. To obtain experimental validation of the diagram, a high-temperature confocal laser scanning microscope (HT-CLSM) is used to rapidly heat or cool a sample, ~ 140 mg, of glassy powder or liquid slag, respectively, to selected isothermal conditions, where it is held for a prescribed length of time before quenching. Identification and quantification of the phases present in the quenched samples are done by a quantitative X-ray powder diffraction analysis (QXRPDA) method that uses a PONKCS (partial or not known crystal structure) procedure based on Le Bail and Rietveld strategies for refinement of diffraction patterns. The many experimental results indicate that the predicted TTT diagrams for devitrification and crystallization of the mold slag give a good estimation of the rate of the transformations that take place at different temperatures and reveal the differences in the reactions that occur along both paths.

36 MATERIALS SCIENCE↗

IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY

Non-metallic structural materials that act as an electrical insulation are needed for cryogenic power applications. One of the extensively utilized materials is glass fiber reinforced resins (GFRR) and may also be known as GFRP and FRP. They are created from glass fiber cloth that are impregnated with an epoxy resin under pressure and heat. Although the materials based on GFRR have been employed extensively, reports about their dielectric properties at cryogenic temperatures and larger thicknesses are generally lacking in the literature. Therefore to guide electrical apparatus designers for cryogenic applications, GFRR samples with different thicknesses are tested in a liquid nitrogen bath. Scaling relation between the dielectric breakdown strength and the GFFR thickness is established. Their loss tangents are also reported at various frequencies.

36 MATERIALS SCIENCE↗

Nonequilibrium study of the intrinsic free-energy profile across a liquid-vapour interface

We calculate an atomistically detailed free-energy profile across a heterogeneous system using a nonequilibrium approach. The path-integral formulation of Crooks fluctuation theorem is used in conjunction with the intrinsic sampling method to calculate the free-energy profile for the liquid-vapour interface of the Lennard-Jones fluid. Free-energy barriers are found corresponding to the atomic layering in the liquid phase as well as a barrier associated with the presence of an adsorbed layer as revealed by the intrinsic density profile. Our findings are in agreement with profiles calculated using Widom’s potential distribution theorem applied to both the average and the intrinsic profiles as well as the literature values for the excess chemical potential.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Characterization and Application of a Hybrid Optical Microscopy/Laser Ablation Liquid Vortex Capture/Electrospray Ionization System for Mass Spectrometry Imaging with Sub-micrometer Spatial Resolution

Herein, a commercial optical microscope, laser microdissection instrument was coupled with an electrospray ionization mass spectrometer via a low profile liquid vortex capture probe to yield a hybrid optical microscopy/mass spectrometry imaging system. The instrument has bright-field and fluorescence microscopy capabilities in addition to a highly focused UV laser beam that is utilized for laser ablation of samples. With this system, material laser ablated from a sample using the microscope was caught by a liquid vortex capture probe and transported in solution for analysis by electrospray ionization mass spectrometry. Both lane scanning and spot sampling mass spectral imaging modes were used. The smallest area the system was able to ablate was ~0.544 μm × ~0.544 μm, achieved by oversampling of the smallest laser ablation spot size that could be obtained (~1.9 μm). With use of a model photoresist surface, known features as small as ~1.5 μm were resolved. The capabilities of the system with real world samples were demonstrated first with a blended polymer thin film containing poly(2-vinylpyridine) and poly(N-vinylcarbazole). Using spot sampling imaging, sub-micrometer sized features (0.62, 0.86, and 0.98 μm) visible by optical microscopy were clearly distinguished in the mass spectral images. A second real world example showed the imaging of trace amounts of cocaine in mouse brain thin tissue sections. Lastly, with use of a lane scanning mode with ~6 μm × ~6 μm data pixels, features in the tissue as small as 15 μm in size could be distinguished in both the mass spectral and optical images.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

L-DOPA Preloading Increases the Uptake of Borophenylalanine in C6 Glioma Rat Model: A New Strategy to Improve BNCT Efficacy

Purpose: Boron neutron capture therapy (BNCT) is a radiotherapeutic modality based on {sup 10}B(n,{alpha}){sup 7}Li reaction, for the treatment of malignant gliomas. One of the main limitations for BNCT effectiveness is the insufficient intake of {sup 10}B nuclei in the tumor cells. This work was aimed at investigating the use of L-DOPA as a putative enhancer for {sup 10}B-drug 4-dihydroxy-borylphenylalanine (BPA) uptake in the C6-glioma model. The investigation was first performed in vitro and then extended to the animal model. Methods and Materials: BPA accumulation in C6-glioma cells was assessed using radiowave dielectric spectroscopy, with and without L-DOPA preloading. Two L-DOPA incubation times (2 and 4 hours) were investigated, and the corresponding effects on BPA accumulation were quantified. C6-glioma cells were also implanted in the brain of 32 rats, and tumor growth was monitored by magnetic resonance imaging. Rats were assigned to two experimental branches: (1) BPA administration; (2) BPA administration after pretreatment with L-DOPA. All animals were sacrificed, and assessments of BPA concentrations in tumor tissue, normal brain, and blood samples were performed using high-performance liquid chromatography. Results: L-DOPA preloading induced a massive increase of BPA concentration in C6-glioma cells only after a 4-hour incubation. In the animal model, L-DOPA pretreatment produced a significantly higher accumulation of BPA in tumor tissue but not in normal brain and blood samples. Conclusions: This study suggests the potential use of L-DOPA as enhancer for BPA accumulation in malignant gliomas eligible for BNCT. L-DOPA preloading effect is discussed in terms of membrane transport mechanisms.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Electrostatic levitation facility optimized for neutron diffraction studies of high temperature liquids at a spallation neutron source

Neutron diffraction studies of metallic liquids provide valuable information about inherent topological and chemical ordering on multiple length scales as well as insight into dynamical processes at the level of a few atoms. However, there exist very few facilities in the world that allow such studies to be made of reactive metallic liquids in a containerless environment, and these are designed for use at reactor-based neutron sources. We present an electrostatic levitation facility, NESL (for Neutron ElectroStatic Levitator), which takes advantage of the enhanced capabilities and increased neutron flux available at spallation neutron sources (SNSs). NESL enables high quality elastic and inelastic neutron scattering experiments to be made of reactive metallic and other liquids in the equilibrium and supercooled temperature regime. The apparatus is comprised of a high vacuum chamber, external and internal neutron collimation optics, and a sample exchange mechanism that allows up to 30 samples to be processed between chamber openings. Two heating lasers allow excellent sample temperature homogeneity, even for samples approaching 500 mg, and an automated temperature control system allows isothermal measurements to be conducted for times approaching 2 h in the liquid state, with variations in the average sample temperature of less than 0.5%. To demonstrate the capabilities of the facility for elastic scattering studies of liquids, a high quality total structure factor for Zr{sub 64}Ni{sub 36} measured slightly above the liquidus temperature is presented from experiments conducted on the nanoscale-ordered materials diffractometer (NOMAD) beam line at the SNS after only 30 min of acquisition time for a small sample (∼100 mg)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Exploring dynamic surface processes during silicate mineral (wollastonite) dissolution with liquid cell

Most liquid cell transmission electron microscopy (LC TEM) studies focus on nanoparticles or nanowires, in large part because the preparation and study of materials in this size range is straightforward. By contrast, this is not true for samples in the micrometre size range, in large part because of the difficulties associated with sample preparation starting from a ‘bulk’ material. There are also many advantages inherent to the study of micrometre-sized samples compared to their nanometre-sized counterparts. Here, we present a liquid cell transmission electron study that employed an innovative sample preparation technique using focused ion beam (FIB) milling to fabricate micrometre-sized electron transparent lamellae that were then welded to the liquid cell substrate. This technique, for which we have described in detail all of the fabrication steps, allows for samples having dimensions of several square micrometres to be observed by TEM in situ in a liquid. We applied this technique to test whether we could observe and measure in situ dissolution of a crystalline material called wollastonite, a calcium silicate mineral. More specifically, this study was used to observe and record surface dynamics associated with step and terrace edge movement, which are ultimately linked to the overall rate of dissolution. The wollastonite lamella underwent chemical reactions in pure deionized water at ambient temperature in a liquid cell with a 5-math formulam-spacer thickness. The movement of surface steps and terraces was measured periodically over a period of almost 5 h. Quite unexpectedly, the one-dimensional rates of retreat of these surface features were not constant, but changed over time. In addition, there were noticeable quantitative differences in retreat rates as a function crystallographic orientation, indicating that surface retreat is anisotropic. Several bulk rates of dissolution were also determined (1.6–4.2 • 10 -7 mol m -2 s -1 ) using the rates of retreat of representative terraces and steps, and were found to be within one order of magnitude of dissolution rates in the literature based on aqueous chemistry data.

36 MATERIALS SCIENCE↗

Nanoflow electrospinning serial femtosecond crystallography

A low flow rate liquid microjet method for delivery of hydrated protein crystals to X-ray lasers is presented. Linac Coherent Light Source data demonstrates serial femtosecond protein crystallography with micrograms, a reduction of sample consumption by orders of magnitude. An electrospun liquid microjet has been developed that delivers protein microcrystal suspensions at flow rates of 0.14–3.1 µl min{sup −1} to perform serial femtosecond crystallography (SFX) studies with X-ray lasers. Thermolysin microcrystals flowed at 0.17 µl min{sup −1} and diffracted to beyond 4 Å resolution, producing 14 000 indexable diffraction patterns, or four per second, from 140 µg of protein. Nanoflow electrospinning extends SFX to biological samples that necessitate minimal sample consumption.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Field Test Report: NETL Portable Raman Gas Composition Monitor Initial Industrial tests at NETL and General Electric (GE)

NETL has developed new technology which enables the use of Raman spectroscopy in the real-time measurement of gas mixtures. This technology uses a hollow reflective metal-lined capillary waveguide as a gas sampling cell which contains the sample gas, and efficiently collects optical Raman scattering from the gas sample, for measurement with a miniature spectrometer. The result is an optical Raman “fingerprint” for each gas which is tens or hundreds of times larger than that which can be collected with conventional free-space optics. In this manner, the new technology exhibits a combination of measurement speed and accuracy which is unprecedented for spontaneous Raman measurements of gases. This makes the system especially well-suited to gas turbine engine control based on a-priori measurement of incoming fuel composition. The system has been developed to produce a measurement of all of the common components of natural gas, including the lesser nitrogen, oxygen, carbon-dioxide, and carbon monoxide diluents to better than 1% concentration accuracy each second. The objective of this task under CRADA 10-N100 was to evaluate the capability of a laser Raman capillary gas sensor for combustion fuels. A portable version of the Raman gas sensor, constructed at NETL, was used for field-trials conducted in a cooperative research effort at a GE facility. Testing under the CRADA was performed in 5 parts. Parts 1-4 were successful in testing of the Raman Gas Composition Monitor with bottled calibration gases, and in continuous monitoring of several gas streams at low pressure, in comparison with an online mass spectrometer. In part 5, the Raman Gas Composition Monitor was moved outdoors for testing with high pressure gas supplies. Some difficulties were encountered during industrial testing including the condensation of heavy hydrocarbons inside the sample cell (in part 5), communication with the GE data collection system, as well as some drift in the optical noise background. The difficulties with liquid contaminants will be overcome through the use of prodigious sample-cell heating and additional line filtration including liquid ingress-protection. The communication problem was resolved through site-specific troubleshooting of the MODBUS data tags.

25 ENERGY STORAGE↗

Field Test Report: NETL Portable Raman Gas Composition Monitor - Initial Industrial tests at NETL and General Electric (GE)

NETL has developed new technology which enables the use of Raman spectroscopy in the real-time measurement of gas mixtures. This technology uses a hollow reflective metal-lined capillary waveguide as a gas sampling cell which contains the sample gas, and efficiently collects optical Raman scattering from the gas sample, for measurement with a miniature spectrometer. The result is an optical Raman “fingerprint” for each gas which is tens or hundreds of times larger than that which can be collected with conventional free-space optics. In this manner, the new technology exhibits a combination of measurement speed and accuracy which is unprecedented for spontaneous Raman measurements of gases. This makes the system especially well-suited to gas turbine engine control based on a-priori measurement of incoming fuel composition. The system has been developed to produce a measurement of all of the common components of natural gas, including the lesser nitrogen, oxygen, carbon-dioxide, and carbon monoxide diluents to better than 1% concentration accuracy each second. The objective of this task under CRADA 10-N100 was to evaluate the capability of a laser Raman capillary gas sensor for combustion fuels. A portable version of the Raman gas sensor, constructed at NETL, was used for field-trials conducted in a cooperative research effort at a GE facility. Testing under the CRADA was performed in 5 parts. Parts 1-4 were successful in testing of the Raman Gas Composition Monitor with bottled calibration gases, and in continuous monitoring of several gas streams at low pressure, in comparison with an online mass spectrometer. In part 5, the Raman Gas Composition Monitor was moved outdoors for testing with high pressure gas supplies. Some difficulties were encountered during industrial testing including the condensation of heavy hydrocarbons inside the sample cell (in part 5), communication with the GE data collection system, as well as some drift in the optical noise background. The difficulties with liquid contaminants will be overcome through the use of prodigious sample-cell heating and additional line filtration including liquid ingress-protection. The communication problem was resolved through site-specific troubleshooting of the MODBUS data tags.

25 ENERGY STORAGE↗

Alternative Liquid DSA Containers for Sludge Slurry Storage in the SRNL Shielded Cells

A pending revision of the Documented Safety Analysis (DSA) for the Savannah River National Laboratory (SRNL) defines “DSA containers” for liquid sludge slurries as containers not susceptible to a flashing spray release in a fire and requires that a list of DSA containers be maintained. High Level Waste (HLW) samples are typically received from the Savannah River Site (SRS) tank farm after retrieval from the storage tanks. Glass bottles are preferred for long-term storage of radioactive liquid sludge slurry samples but are not on the DSA container list. An evaluation has been conducted to identify vessel lids for the glass bottles that would vent prior to pressurization and liquid superheating in a fire event. Low melting Field’s Metal eutectic alloy with a melting point of 62 °C has been identified as a preferred material of construction for vessel lids for this application because the material is resistant to puncture and is expected to have good chemical compatibility and radiation stability in the shielded cells environment. A test vessel was designed to evaluate the alloy and confirm that it would melt before the water in the vessel reaches the boiling point. The tests confirmed: 1) that the reported melting point of the alloy was accurate, 2) that a top fashioned from this material will melt creating an open atmosphere in the vessel headspace prior to sample boiling under moderate and fast heating rates, and 3) that nonuniform heating of the bottle from the bottom also results in melting of the alloy prior to boiling. Based on the results, neither an engulfing fire with standing or toppled bottles or a fire producing localized heat at the vessel bottom would result in flashing spray conditions.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Plastic scintillators: a powerful tool to reduce mixed waste

Wastes containing radioactive and organic compounds (mixed wastes) are difficult to dispose because of the regulations established for nuclear and hazardous wastes. Mixed wastes originate mainly in the emulsions generated in beta emitter determinations by Liquid Scintillation techniques. The use of plastic scintillators instead of liquid cocktails may facilitate the segregation, after measurement, of sample and scintillator without introducing additional wastes in the measurement step. In this study, we compare the capability of Plastic Scintillation (PS) versus Liquid Scintillation (LS) and Cerenkov (C) techniques to determine beta emitters in routine measurements. Results obtained show that high and medium energy beta emitters (Sr-90/Y-90 and C-14) can be quantified in aqueous samples by using PS with similar relative errors (< 5%) as those obtained by LS or C, for any activity level considered. For low energy emitters (H-3), best results using PS are achieved for medium activity levels. Additionally, measurements performed in solutions including alpha (Pu-238) and beta-gamma (Cs-134) emitters confirm the capability of PS to extent the application of this technique to the determination of these types of isotopes. (authors)

54 ENVIRONMENTAL SCIENCES↗