Search NASA⌕ Search

SEARCH · Search NASA

Results for “MASER”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 721 records · Page 40

A Face-on Accretion System in High-mass Star Formation: Possible Dusty Infall Streams within 100 AU

We report on interferometric observations of a face-on accretion system around the high-mass young stellar object, G353.273+0.641. The innermost accretion system of 100 au radius was resolved in a 45 GHz continuum image taken with the Jansky-Very Large Array. Our spectral energy distribution analysis indicated that the continuum could be explained by optically thick dust emission. The total mass of the dusty system is ∼0.2 M {sub ☉} at minimum and up to a few M {sub ☉} depending on the dust parameters. 6.7 GHz CH{sub 3}OH masers associated with the same system were also observed with the Australia Telescope Compact Array. The masers showed a spiral-like, non-axisymmetric distribution with a systematic velocity gradient. The line-of-sight velocity field is explained by an infall motion along a parabolic streamline that falls onto the equatorial plane of the face-on system. The streamline is quasi-radial and reaches the equatorial plane at a radius of 16 au. This is clearly smaller than that of typical accretion disks in high-mass star formation, indicating that the initial angular momentum was very small, or the CH{sub 3}OH masers selectively trace accreting material that has small angular momentum. In the former case, the initial specific angular momentum is estimated to be 8 × 10{sup 20} (M{sub ∗}/10 M {sub ☉}){sup 0.5} cm{sup 2} s{sup −1}, or a significant fraction of the initial angular momentum was removed outside of 100 au. The physical origin of such a streamline is still an open question and will be constrained by the higher-resolution (∼10 mas) thermal continuum and line observations with ALMA long baselines.

79 ASTRONOMY AND ASTROPHYSICS↗

An Extraordinary Outburst in the Massive Protostellar System NGC 6334I-MM1: Quadrupling of the Millimeter Continuum

Based on sub-arcsecond Atacama Large Millimeter/submillimeter Array (ALMA) and Submillimeter Array (SMA) 1.3 mm continuum images of the massive protocluster NGC 6334I obtained in 2015 and 2008, we find that the dust emission from MM1 has increased by a factor of 4.0 ± 0.3 during the intervening years, and undergone a significant change in morphology. The continuum emission from the other cluster members (MM2, MM4, and the UCH ii region MM3 = NGC 6334F) has remained constant. Long-term single-dish maser monitoring at HartRAO finds that multiple maser species toward NGC 6334I flared beginning in early 2015, a few months before our ALMA observation, and some persist in that state. New ALMA images obtained in 2016 July–August at 1.1 and 0.87 mm confirm the changes with respect to SMA 0.87 mm images from 2008, and indicate that the (sub)millimeter flaring has continued for at least a year. The excess continuum emission, centered on the hypercompact H ii region MM1B, is extended and elongated (1.″6 × 1.″0 ≈ 2100 × 1300 au) with multiple peaks, suggestive of general heating of the surrounding subcomponents of MM1, some of which may trace clumps in a fragmented disk rather than separate protostars. In either case, these remarkable increases in maser and dust emission provide direct observational evidence of a sudden accretion event in the growth of a massive protostar yielding a sustained luminosity surge by a factor of 70 ± 20, analogous to the largest events in simulations by Meyer et al. This target provides an excellent opportunity to assess the impact of such a rare event on a protocluster over many years.

79 ASTRONOMY AND ASTROPHYSICS↗

On the Nature of the Enigmatic Object IRAS 19312+1950: A Rare Phase of Massive Star Formation?

IRAS19312+1950 is a peculiar object that has eluded firm characterization since its discovery, with combined maser properties similar to an evolved star and a young stellar object (YSO). To help determine its true nature, we obtained infrared spectra of IRAS19312+1950 in the range 5-550 microns using the Herschel and Spitzer space observatories. The Herschel PACS maps exhibit a compact, slightly asymmetric continuum source at 170 microns, indicative of a large, dusty circumstellar envelope. The far-IR CO emission line spectrum reveals two gas temperature components: approx. = 0.22 Stellar Mass of material at 280+/-18 K, and ≈1.6 Me of material at 157+/-3 K. The OI 63 micron line is detected on-source but no significant emission from atomic ions was found. The HIFI observations display shocked, high-velocity gas with outflow speeds up to 90 km/s along the line of sight. From Spitzer spectroscopy, we identify ice absorption bands due to H2O at 5.8 microns and CO2 at 15 microns. The spectral energy distribution is consistent with a massive, luminous (approx. 2 × 10(exp 4) Stellar Luminosity) central source surrounded by a dense, warm circumstellar disk and envelope of total mass approx. 500-700 Stellar Mass with large bipolar outflow cavities. The combination of distinctive far-IR spectral features suggest that IRAS19312+1950 should be classified as an accreting, high-mass YSO rather than an evolved star. In light of this reclassification, IRAS19312+1950 becomes only the fifth high-mass protostar known to exhibit SiO maser activity, and demonstrates that 18 cm OH maser line ratios may not be reliable observational discriminators between evolved stars and YSOs.

ISM: molecules aEuro" masers aEuro" stars↗

NuSTAR Observations of Water Megamaser AGN

Aims. We study the connection between the masing disk and obscuring torus in Seyfert 2 galaxies. Methods. We present a uniform X-ray spectral analysis of the high energy properties of 14 nearby megamaser active galactic nuclei observed by NuSTAR. We use a simple analytical model to localize the maser disk and understand its connection with the torus by combining NuSTAR spectral parameters with the available physical quantities from VLBI mapping.Results. Most of the sources that we analyzed are heavily obscured, showing a column density in excess of approx.10(exp 23) cm(exp -2); in particular, 79% are Compton-thick [NH is greater than 1.5 x 10(exp 24) cm(exp -2)]. When using column densities measured by NuSTAR with the assumption that the torus is the extension of the maser disk, and further assuming a reasonable density profile, we can predict the torus dimensions. They are found to be consistent with mid-IR interferometry parsec-scale observations of Circinus and NGC 1068. In this picture, the maser disk is intimately connected to the inner part of the torus. It is probably made of a large number of molecular clouds that connect the torus and the outer part of the accretion disk, giving rise to a thin disk rotating in most cases in Keplerian or sub-Keplerian motion. This toy model explains the established close connection between water megamaser emission and nuclear obscuration as a geometric effect.

masers / galaxies: active / galaxies: Seyfert↗

Toward Ultra‐High‐Quality‐Factor Wireless Masing Magnetic Resonance Sensing

It has recently been shown that a bolus of hyperpolarized nuclear spins can yield stimulated emission signals similar in nature to maser signals, potentially enabling new ways of sensing hyperpolarized contrast media, including most notably [1- 13 C]pyruvate that is under evaluation in over 50 clinical trials for metabolic imaging of cancer. The stimulated NMR signal emissions lasting for minutes do not require radio-frequency excitation, offering unprecedented advantages compared to conventional MR sensing. However, creating nuclear spin maser emission is challenging in practice due to stringent fundamental requirements, making practical in vivo applications hardly possible using conventional passive MR detectors. Here, in this study, we demonstrate the utility of a wireless NMR maser detector, the quality factor of which was enhanced 22-fold (to 1,670) via parametric pumping. This active-feedback technique breaks the intrinsic fundamental limit of NMR detector circuit quality factor. We show the use of parametric pumping to reduce the threshold requirement for inducing nuclear spin masing at 300 MHz resonance frequency in a preclinical MRI scanner. Indeed, stimulated emission from hyperpolarized protons was obtained under highly unfavorable conditions of low magnetic field homogeneity (T 2 * of 3 ms). Greater gains of the quality factor of the MR detector (up to 1 million) were also demonstrated.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

THE MEGAMASER COSMOLOGY PROJECT. II. THE ANGULAR-DIAMETER DISTANCE TO UGC 3789

The Megamaser Cosmology Project (MCP) aims to determine H {sub 0} by measuring angular-diameter distances to galaxies in the Hubble flow using observations of water vapor megamasers in the circumnuclear accretion disks of active galaxies. The technique is based only on geometry and determines H {sub 0} in one step, independent of standard candles and the extragalactic distance ladder. In Paper I, we presented a very long baseline interferometry map of the maser emission from the Seyfert 2 galaxy UGC 3789. The map reveals an edge-on, sub-parsec disk in Keplerian rotation, analogous to the megamaser disk in NGC 4258. Here, we present 3.2 years of monthly Green Bank Telescope observations of the megamaser disk in UGC 3789. We use these observations to measure the centripetal accelerations of both the systemic and high-velocity maser components. The measured accelerations suggest that maser emission lines near the systemic velocity originate on the front side of the accretion disk, primarily from segments of two narrow rings. Adopting a two-ring model for the systemic features, we determine the angular-diameter distance to UGC 3789 to be 49.9 {+-} 7.0 Mpc. This is the most accurate geometric distance to a galaxy in the Hubble flow yet obtained. Based on this distance, we determine H {sub 0} = 69 {+-} 11 km s{sup -1} Mpc{sup -1}. We also measure the mass of the central black hole to be 1.09 x 10{sup 7} M{sub sun} {+-}14%. With additional observations, the uncertainty in the distance to this galaxy can be reduced to under 10%. Observations of megamaser disks in other galaxies will further reduce the uncertainty in H {sub 0} as measured by the MCP.

79 ASTRONOMY AND ASTROPHYSICS↗

THE BOLOCAM GALACTIC PLANE SURVEY. XIV. PHYSICAL PROPERTIES OF MASSIVE STARLESS AND STAR-FORMING CLUMPS

We sort 4683 molecular clouds between 10° < ℓ < 65° from the Bolocam Galactic Plane Survey based on observational diagnostics of star formation activity: compact 70 μm sources, mid-IR color-selected YSOs, H{sub 2}O and CH{sub 3}OH masers, and UCH ii regions. We also present a combined NH{sub 3}-derived gas kinetic temperature and H{sub 2}O maser catalog for 1788 clumps from our own GBT 100 m observations and from the literature. We identify a subsample of 2223 (47.5%) starless clump candidates (SCCs), the largest and most robust sample identified from a blind survey to date. Distributions of flux density, flux concentration, solid angle, kinetic temperature, column density, radius, and mass show strong (>1 dex) progressions when sorted by star formation indicator. The median SCC is marginally subvirial (α ∼ 0.7) with >75% of clumps with known distance being gravitationally bound (α < 2). These samples show a statistically significant increase in the median clump mass of ΔM ∼ 170–370 M {sub ⊙} from the starless candidates to clumps associated with protostars. This trend could be due to (i) mass growth of the clumps at M-dot ∼200--440 M {sub ⊙} Myr{sup −1} for an average freefall 0.8 Myr timescale, (ii) a systematic factor of two increase in dust opacity from starless to protostellar phases, and/or (iii) a variation in the ratio of starless to protostellar clump lifetime that scales as ∼M {sup −0.4}. By comparing to the observed number of CH{sub 3}OH maser containing clumps, we estimate the phase lifetime of massive (M > 10{sup 3} M {sub ⊙}) starless clumps to be 0.37 ± 0.08 Myr (M/10{sup 3} M {sub ⊙}){sup −1}; the majority (M < 450 M {sub ⊙}) have phase lifetimes longer than their average freefall time.

79 ASTRONOMY AND ASTROPHYSICS↗

Rubidium-87 gas cell studies, phase 2

A description is given of the development of a compact rubidium-87 maser. Data cover the electronic control system for the maser itself and a superhetrodyne receiver capable of locking a crystal oscillator to the maser signal.

Vanier, J.↗

Microwave emission from stars.

An attempt is made to summarize the observations of masered emission from stars and to outline some basic conclusions that can be drawn from the data. The association of masered microwave emission with well studied objects like stars makes it possible to use the information gathered by conventional optical observations to attack the general masering problem and, conversely, the radio observations may be used to obtain information about a star not readily accessible optically, such as the mass loss rate or the physical conditions in a circumstellar shell.

Schwartz, P. R.↗

NASA atomic hydrogen standards program: An update

Comparisons are made between the NP series and the NX series of hydrogen masers. A field operable hydrogen maser (NR series) is also described. Atomic hydrogen primary frequency standards are in development stages. Standards are being developed for a hydrogen beam frequency standard and for a concertina hydrogen maser.

Reinhardt, V. S.↗

Search for radiation from the 2 pi 1/2, J = 5/2 state of interstellar CH

The note reports results of an unsuccessful search for the four hyperfine transitions in the cited rotational state of interstellar CH, which was performed using a 25.6-m radio telescope equipped with a traveling-wave maser radiometer. The frequency interval covered ranged from 4677 to 4850 MHz; the sources observed were W3 Cont, W51, Orion A, and IRC+10216. It is shown that the lines in the present excited state cannot be expected to be observed if the state is populated according to thermodynamic equilibrium at the kinetic temperature of the medium. The possibility is considered of detecting thermally excited CH in a more compact region and of detecting excited-state CH maser lines. It is concluded that no strong CH maser lines exist for the frequencies and sources covered.

Sume, A.↗

Low-noise receivers: S-band parametric up converter development

The combination of a cryogenically-cooled parametric upconverter and a higher frequency maser post amplifier was proposed as a method of achieving maser-like receiver noise temperatures over much larger instantaneous bandwidths and tuning ranges than are presently obtainable with masers in the range of 1 to 18 GHz. An experimental 2.0- to 2.5-GHz parametric upconverter/maser system was developed to explore these possibilities. Initial tests of this system resulted in an effective input noise temperature of 3.1 K at 2295 MHz and 3.2 K at 2388 MHz. The parametric upconverter logged over 1500 hours at 4.5 K and underwent 5 thermal cycles (300 K to 4.5 K to 300 K) without degradation.

Petty, S.↗

Gravitational redshift space-probe experiment

A Scout D rocket was launched from Wallops Island, Virginia, carrying an atomic hydrogen maser oscillator system as the payload. The frequency of signals from the oscillator was monitored on the ground at Merritt Island, Florida, by using two hydrogen masers as comparison oscillators. The first-order Doppler shift in the signals was eliminated by a go-return transponder link to the payload, and the resulting data, representing the relativistic shifts, were recovered and recorded. The objective was to measure directly the effect of gravitational potential on the frequency of an atomic hydrogen maser assuming it to be a 'proper' clock. A gravitational effect amounting to some 4.5 parts in 10 to the 10th power was measured with an oscillator having a stability better than 1 part in 10 to the 14th power. Therefore, to make the best possible use of the oscillator, all frequency shifts at the 2 to 5 X 10 to the -15 power level in delta f/f in the system must be accounted for. This includes all the phase variations that can cause such a shift to appear. The experiment, the data available and the manner in which they were processed, and the results are described.

Vessot, R. F. C.↗

Radio astronomy

A K-band reflected-wave ruby maser was used on the 64-meter (DSS-43) antenna at the Tidbinbilla Tracking Station, near Canberra, Australia. Spectral line observations were carried out near 22 GHz for water vapor sources and near 24 GHz for ammonia sources. The water vapor observations were made in the direction of known southern OH and H2O maser sources. All of the previously detected water line sources examined were detected. In addition, two new water vapor maser sources were discovered, G301.1+1.1and G308.9+0.1. The spectrum of G301.0+1.1 is presented six ammonia sources were found: G291.3-0.7, G305.4+0.2, G322.2+0.6, G327.3-0.5, G333.6-0.2, and G268.4-0.8. Spectra of two of these sources, G291.3-0.7 (RCW 57) and G305.4+0.2, are presented. Both show clearly the presence of the quadrupole splitting satellite lines that will allow the determination of NH3 optical depths in these clouds.

Shaffer, R. D.↗

Cryogenic filters for RFI protection

The increased bandwidth and sensitivity of the DSN maser-based receiver systems along with the increase in worldwide microwave spectrum usage dictated the need for employing additional measures to protect these systems from RFI (radio frequency inerference). Both in-band and out-of-band microwave signals at the input of the Deep Space Network (DSN) traveling wave masers (TWM) can adversely affect the maser performance in a variety of ways. Filters fabricated from superconducting materials operating below their superconducting transition temperature (Tc) possess the most potential for providing the necessary RFI protection without degrading the system performance.

Bautista, J. J.↗

The development of a magnetically enhanced hydrogen gas dissociation

Application of a dc magnetic field on an RF hydrogen gas dissociator led to the development of a more efficient source of atoms for hydrogen masers. The influence of the applied magnetic field on the plasma and some details of the resulting enhancement of the dissociation efficiency are discussed. Ways that this improved efficiency can result in the enhancement of the operation and field life of hydrogen masers, as well as aid the development of spaceborne masers, are considered.

Maleki, L.↗

Low noise buffer amplifiers and buffered phase comparators for precise time and frequency measurement and distribution

Extremely low noise, high performance, wideband buffer amplifiers and buffered phase comparators were developed. These buffer amplifiers are designed to distribute reference frequencies from 30 KHz to 45 MHz from a hydrogen maser without degrading the hydrogen maser's performance. The buffered phase comparators are designed to intercompare the phase of state of the art hydrogen masers without adding any significant measurement system noise. These devices have a 27 femtosecond phase stability floor and are stable to better than one picosecond for long periods of time. Their temperature coefficient is less than one picosecond per degree C, and they have shown virtually no voltage coefficients.

Eichinger, R. A.↗

Satellite time and frequency transfer (STIFT)

The concept of placing a hydrogen maser high stability clock in Earth orbit to provide accurate time and frequency comparisons worldwide to major timing centers and to a large number of radio observatory antenna sites involved in VLBI measurements was studied. The proposal was chiefly directed toward studies and initial hardware designs for time comparisons between hydrogen maser frequency standards and to modifications of the hydrogen maser for long-term use in space.

Vessot, R. F. C.↗