Search NASA⌕ Search

SEARCH · Search NASA

Results for “MM”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 721 records · Page 40

Diffusion-weighted imaging as a part of PET/MR for small lesion detection in patients with primary abdominal and pelvic cancer, with or without TOF reconstruction technique

Objectives: To investigate the value of diffusion-weighted imaging (DWI) in detection of small lesions (≤ 10 mm) in patients with primary abdominal and pelvic cancer in hybrid PET/MR with or without time-of-flight (TOF) technique. Materials and methods: Twenty patients (11 females and 9 males, mean age 67.23 ± 12.90 years) with histologically confirmed primary abdominal and pelvic cancer underwent hybrid PET/MR examination. A total of 64 small lesions were included in this study, which were divided into two groups (≤ 10 mm and 10–30 mm). Visual scores of small lesion detection ability were rated by five-point ordinal scale. The visual scores and detectability of small lesions on TOF PET image, noTOF PET image, and DWI sequences of hybrid PET/MR examination with or without TOF technique were analyzed. Logistic regression model was established for analysis in the value of DWI in hybrid PET/MR examination with or without TOF technique in detection of the small lesions between two groups. Results: The visual evaluation revealed the small lesion (≤ 10 mm) visual scores of DWI (mean ± SD: 4.23 ± 1.41), TOF PET image (mean ± SD: 4.14 ± 0.89), and noTOF PET image (mean ± SD: 2.68 ± 1.13);.and the visual scores of small lesions (10–30 mm) on DWI (mean ± SD: 4.98 ± 0.15), TOF PET image (mean ± SD: 4.57 ± 0.59), and noTOF PET image (mean ± SD: 3.98 ± 1.05). The visual scores of all small lesions on DWI were higher than that on TOF PET data and noTOF PET data in both two groups (**P < 0.01). The missed diagnosis rates of small FDG avid lesions (≤ 10 mm) of DWI and noTOF PET image were 9.1% and 9.1%, respectively. However, the TOF PET-based clinical diagnosis detected all small lesions (≤ 30 mm). DWI was of great importance in detection of small lesions (≤ 10 mm) in the absence of TOF technique in PET/MR examination (**P < 0.01). DWI’s effect on detection of small lesions(10-30 mm) has shown no difference between PET/MR examinations with TOF and without TOF techniques (P > 0.05). Conclusion: DWI has significant value in the detection of small lesions (≤ 10 mm) in hybrid PET/MR examination without TOF technique for patients with primary abdominal and pelvic cancer. However, it had less detection benefits in the small lesions (≤ 10 mm) in hybrid PET/MR examination with TOF PET image.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Deformable Registration for Longitudinal Breast MRI Screening

MRI screening of high-risk patients for breast cancer provides very high sensitivity, but with a high recall rate and negative biopsies. Comparing the current exam to prior exams reduces the number of follow-up procedures requested by radiologists. Such comparison, however, can be challenging due to the highly deformable nature of breast tissues. Automated co-registration of multiple scans has the potential to aid diagnosis by providing 3D images for side-by-side comparison and also for use in CAD systems. Although many deformable registration techniques exist, they generally have a large number of parameters that need to be optimized and validated for each new application. Here, we propose a framework for such optimization and also identify the optimal input parameter set for registration of 3D T{sub 1}-weighted MRI of breast using Elastix, a widely used and freely available registration tool. A numerical simulation study was first conducted to model the breast tissue and its deformation through finite element (FE) modeling. This model generated the ground truth for evaluating the registration accuracy by providing the deformation of each voxel in the breast volume. An exhaustive search was performed over various values of 7 registration parameters (4050 different combinations of parameters were assessed) and the optimum parameter set was determined. This study showed that there was a large variation in the registration accuracy of different parameter sets ranging from 0.29 mm to 2.50 mm in median registration error and 3.71 mm to 8.90 mm in 95 percentile of the registration error. Mean registration errors of 0.32 mm, 0.29 mm, and 0.30 mm and 95 percentile errors of 3.71 mm, 5.02 mm, and 4.70 mm were obtained by the three best parameter sets. The optimal parameter set was applied to consecutive breast MRI scans of 13 patients. A radiologist identified 113 landmark pairs (~ 11 per patient) which were used to assess registration accuracy. The results demonstrated that using the optimal registration parameter set, a registration accuracy (in mm) of 3.4 [1.8 6.8] was achieved.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Empirical Characterization and Modeling of Cohesive – to – Adhesive Shear Fracture Mode Transition due to Increased Adhesive Layer Thicknesses of Fiber Reinforced Composite Single – Lap Joints

Here, to ensure a strong adhesive bond, most standards and adhesive manufacturers specify a maximum adhesive gap of 1 mm when bonding fiber reinforced composite structures. In manufacturing large components, such as joining two halves of wind turbine blades, meeting this gap tolerance specification is impractical; gaps larger than 10 mm are common in large adhesively bonded composite structures using state-of-the-art manufacturing techniques. Currently, there is a lack of fundamental understanding of the failure mechanics of adhesive gaps larger than 3 mm. To create such understanding, glass fiber - acrylic thermoplastic composite panels bonded using different epoxy adhesives within single-lap joint samples with adhesive thicknesses of 0.1 mm, 0.3 mm, 1 mm, 3 mm, 5 mm, and 10 mm were sheared to failure. A transition from cohesive to adhesive failure was observed to occur about 1 mm to 3 mm joint thicknesses. Plotting the shear stress normalized by the ratio of the joint width to thickness as a function of the joint thickness normalized by the joint length is shown to result in the ability to fit simple empirically derived models of the cohesive-to-adhesive failure transition, regardless of the adhesive. Furthermore, using these normalized variables, all the observed cohesively failed specimens collapse to a single master curve, as do the adhesively failed specimens.

36 MATERIALS SCIENCE↗

A new treatment for human malignant melanoma targeting L-type amino acid transporter 1 (LAT1): A pilot study in a canine model

Highlights: •LAT1 is highly expressed in tumors but at low levels in normal tissues. •We examine LAT1 expression and function in malignant melanoma (MM). •LAT1 expression in MM tissues and cell lines is higher than those in normal tissues. •LAT1 selective inhibitors inhibit amino acid uptake and cell growth in MM cells. •New chemotherapeutic protocols including LAT1 inhibitors are effective for treatment. -- Abstract: L-type amino acid transporter 1 (LAT1), an isoform of amino acid transport system L, transports branched or aromatic amino acids essential for fundamental cellular activities such as cellular growth, proliferation and maintenance. This amino acid transporter recently has received attention because of its preferential and up-regulated expression in a variety of human tumors in contrast to its limited distribution and low-level expression in normal tissues. In this study, we explored the feasibility of using LAT1 inhibitor as a new therapeutic agent for human malignant melanomas (MM) using canine spontaneous MM as a model for human MM. A comparative study of LAT expression was performed in 48 normal tissues, 25 MM tissues and five cell lines established from MM. The study observed LAT1 mRNA levels from MM tissues and cell lines that were significantly (P < 0.01) higher than in normal tissues. Additionally, MM with distant metastasis showed a higher expression than those without distant metastasis. Functional analysis of LAT1 was performed on one of the five cell lines, CMeC-1. [{sup 3}H]L-Leucine uptake and cellular growth activities in CMeC-1 were inhibited in a dose-dependent manner by selective LAT1 inhibitors (2-amino-2-norbornane-carboxylic acid, BCH and melphalan, LPM). Inhibitory growth activities of various conventional anti-cancer drugs, including carboplatin, cyclophosphamide, dacarbazine, doxorubicin, mitoxantrone, nimustine, vinblastine and vincristine, were significantly (P < 0.05) enhanced by combination use with BCH or LPM. These findings suggest that LAT1 could be a new therapeutic target for MM.

60 APPLIED LIFE SCIENCES↗

Experimental study of lean flammability limits of methane/hydrogen/air mixtures in tubes of different diameters

Lean limit flames in methane/hydrogen/air mixtures propagating in tubes of internal diameters (ID) of 6.0, 8.9, 12.3, 18.4, 25.2, 35.0, and 50.2 mm have been experimentally studied. The flames propagated upward from the open bottom end of the tube to the closed upper end. The content of hydrogen in the fuel gas has been varied in the range 0-40 mol%. Lean flammability limits have been determined; flame shapes recorded and the visible speed of flame propagation measured. Most of the observed limit flames in tubes with diameters in the range of 8.9-18.4 mm had enclosed shape, and could be characterized as distorted or spherical flame balls. The tendency was observed for mixtures with higher hydrogen content to form smaller size, more uniform flame balls in a wider range of tube diameters. At hydrogen content of 20% or more in the fuel gas, limit flames in largest diameters (35.0 mm and 50.2 mm ID) tubes had small, compared to the tube diameter, size and were ''lens''-shaped. ''Regular'' open-front lean limit flames were observed only for the smallest diameters (6.0 mm and 8.9 mm) and largest diameters (35.0 and 50.2 mm ID), and only for methane/air and (90% CH{sub 4} + 10% H{sub 2})/air mixtures, except for 6 mm ID tube in which all limit flames had open front. In all experiments, except for the lean limit flames in methane/air and (90% CH{sub 4} + 10% H{sub 2})/air mixtures in the 8.9 mm ID tube, and all limit flames in 6.0 mm ID tube, visible flame speeds very weakly depended on the hydrogen content in the fuel gas and were close to- or below the theoretical estimate of the speed of a rising hot bubble. This observation suggests that the buoyancy is the major factor which determines the visible flame speed for studied limit flames, except that last mentioned. A decrease of the lean flammability limit value with decreasing the tube diameter was observed for methane/air and (90% CH{sub 4} + 10% H{sub 2})/air mixtures for tubes having internal diameters in the range of 18.4-50.2 mm. This effect has been attributed to the stronger combined effect of the preferential diffusion and flame stretch in narrower tubes for flames which resemble rising bubble. (author)

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Image-Guided Radiotherapy via Daily Online Cone-Beam CT Substantially Reduces Margin Requirements for Stereotactic Lung Radiotherapy

Purpose: To determine treatment accuracy and margins for stereotactic lung radiotherapy with and without cone-beam CT (CBCT) image guidance. Methods and Materials: Acquired for the study were 308 CBCT of 24 patients with solitary peripheral lung tumors treated with stereotactic radiotherapy. Patients were immobilized in a stereotactic body frame (SBF) or alpha-cradle and treated with image guidance using daily CBCT. Four (T1) or five (T2/metastatic) 12-Gy fractions were prescribed to the planning target volume (PTV) edge. The PTV margin was {>=}5 mm depending on a pretreatment estimate of tumor excursion. Initial daily setup was according to SBF coordinates or tattoos for alpha-cradle cases. A CBCT was performed and registered to the planning CT using soft tissue registration of the target. The initial setup error/precorrection position, was recorded for the superior-inferior, anterior-posterior, and medial-lateral directions. The couch was adjusted to correct the tumor positional error. A second CBCT verified tumor position after correction. Patients were treated in the corrected position after the residual errors were {<=}2 mm. A final CBCT after treatment assessed intrafraction tumor displacement. Results: The precorrection systematic ({sigma}) and random errors ({sigma}) for the population ranged from 2-3 mm for SBF and 2-6 mm for alpha-cradle patients; postcorrection errors ranged from 0.4-1.0 mm. Calculated population margins were 9 to 13 mm (SBF) and 10-14 mm (cradle) precorrection, 1-2 mm (SBF), and 2-3 mm (cradle) postcorrection, and 2-4 mm (SBF) and 2-5 mm (cradle) posttreatment. Conclusions: Setup for stereotactic lung radiotherapy using a SBF or alpha-cradle alone is suboptimal. CBCT image guidance significantly improves target positioning and substantially reduces required target margins and normal tissue irradiation.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Interfractional Prostate Shifts: Review of 1870 Computed Tomography (CT) Scans Obtained During Image-Guided Radiotherapy Using CT-on-Rails for the Treatment of Prostate Cancer

Purpose: To review 1870 CT scans of interfractional prostate shift obtained during image-guided radiotherapy. Methods and Materials: A total of 1870 pretreatment CT scans were acquired with CT-on-rails, and the corresponding shift data for 329 patients with prostate cancer were analyzed. Results: Of the 1870 scans reviewed, 44% required no setup adjustments in the anterior-posterior (AP) direction, 14% had shifts of 3-5 mm, 29% had shifts of 6-10 mm, and 13% had shifts of >10 mm. In the superior-inferior direction, 81% had no adjustments, 2% had shifts of 3-5 mm, 15% had shifts of 6-10 mm, and 2% had shifts of >10 mm. In the left-right direction, 65% had no adjustment, 13% had shifts of 3-5 mm, 17% had shifts of 6-10 mm, and 5% had shifts of >10 mm. Further analysis of the first 66 consecutive patients divided into three groups according to body mass index indicates that the shift in the AP direction for the overweight subgroup was statistically larger than those for the control and obese subgroups (p < 0.05). The interfractional shift in the lateral direction for the obese group (1 SD, 5.5 mm) was significantly larger than those for the overweight and control groups (4.1 and 2.9 mm, respectively) (p < 0.001). Conclusions: These data demonstrate that there is a significantly greater shift in the AP direction than in the lateral and superior-inferior directions for the entire patient group. Overweight and obese patient groups show a significant difference from the control group in terms of prostate shift.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Performance of a Novel Repositioning Head Frame for Gamma Knife Perfexion and Image-Guided Linac-Based Intracranial Stereotactic Radiotherapy

Purpose: To evaluate the geometric positioning and immobilization performance of a vacuum bite-block repositioning head frame (RHF) system for Perfexion (PFX-SRT) and linac-based intracranial image-guided stereotactic radiotherapy (SRT). Methods and Materials: Patients with intracranial tumors received linac-based image-guided SRT using the RHF for setup and immobilization. Three hundred thirty-three fractions of radiation were delivered in 12 patients. The accuracy of the RHF was estimated for linac-based SRT with online cone-beam CT (CBCT) and for PFX-SRT with a repositioning check tool (RCT) and offline CBCT. The RCT's ability to act as a surrogate for anatomic position was estimated through comparison to CBCT image matching. Immobilization performance was evaluated daily with pre- and postdose delivery CBCT scans and RCT measurements. Results: The correlation coefficient between RCT- and CBCT-reported displacements was 0.59, 0.75, 0.79 (Right, Superior, and Anterior, respectively). For image-guided linac-based SRT, the mean three-dimensional (3D) setup error was 0.8 mm with interpatient ({Sigma}) and interfraction ({sigma}) variations of 0.1 and 0.4 mm, respectively. For PFX-SRT, the initial, uncorrected mean 3D positioning displacement in stereotactic coordinates was 2.0 mm, with {Sigma} = 1.1 mm and {sigma} = 0.8 mm. Considering only RCT setups <1mm (PFX action level) the mean 3D positioning displacement reduced to 1.3 mm, with {Sigma} = 0.9 mm and {sigma} = 0.4 mm. The largest contributing systematic uncertainty was in the superior-inferior direction (mean displacement = -0.5 mm; {Sigma} = 0.9 mm). The largest mean rotation was 0.6{sup o} in pitch. The mean 3D intrafraction motion was 0.4 {+-} 0.3 mm. Conclusion: The RHF provides excellent immobilization for intracranial SRT and PFX-SRT. Some small systematic uncertainties in stereotactic positioning exist and must be considered when generating PFX-SRT treatment plans. The RCT provides reasonable surrogacy for internal anatomic displacement.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Inter- and Intrafractional Positional Uncertainties in Pediatric Radiotherapy Patients With Brain and Head and Neck Tumors

Purpose: To estimate radiation therapy planning margins based on inter- and intrafractional uncertainty for pediatric brain and head and neck tumor patients at different imaging frequencies. Methods: Pediatric patients with brain (n = 83) and head and neck (n = 17) tumors (median age = 7.2 years) were enrolled on an internal review board-approved localization protocol and stratified according to treatment position and use of anesthesia. Megavoltage cone-beam CT (CBCT) was performed before each treatment and after every other treatment. The pretreatment offsets were used to calculate the interfractional setup uncertainty (SU), and posttreatment offsets were used to calculate the intrafractional residual uncertainty (RU). The SU and RU are the patient-related components of the setup margin (SM), which is part of the planning target volume (PTV). SU data was used to simulate four intervention strategies using different imaging frequencies and thresholds. Results: The SM based on all patients treated on this study was 2.1 mm (SU = 0.9 mm, RU = 1.9 mm) and varied according to treatment position (supine = 1.8 mm, prone = 2.6 mm) and use of anesthesia (with = 1.7 mm, without = 2.5 mm) because of differences in the RU. The average SU for a 2-mm threshold based on no imaging, once per week imaging, initial five images, and daily imaging was 3.6, 2.1, 2.2, and 0.9 mm, respectively. Conclusion: On the basis of this study, the SM component of the PTV may be reduced to 2 mm for daily CBCT compared with 3.5 mm for weekly CBCT. Considering patients who undergo daily pretreatment CBCT, the SM is larger for those treated in the prone position or smaller for those treated under anesthesia because of differences in the RU.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Rectal Motion in Patients Receiving Preoperative Radiotherapy for Carcinoma of the Rectum

Purpose: To assess the movement of rectum, mesorectum, and rectal primary during a course of preoperative chemoradiotherapy. Methods and Materials: Seventeen patients with Stage II or III rectal cancer had a planning CT scan with rectal contrast before commencement of preoperative chemoradiation. The scan was repeated during Weeks 1, 3, and 5 of chemoradiation. The rectal primary (gross tumor volume), rectum, mesorectum, and bladder were contoured on all four scans. An in-house biomechanical model-based deformable image registration technique, Morfeus, was used to measure the three-dimensional spatial change in these structures after bony alignment. The required planning target volume margin for this spatial change, after bone alignment, was also calculated. Results: Rectal contrast was found to introduce a systematic error in the position of all organs compared with the noncontrast state. The largest change in structures during radiotherapy was in the anterior and posterior directions for the mesorectum and rectum and in the superior and inferior directions for the gross tumor volume. The planning target volume margins required for internal movement for the mesorectum based on the three scans acquired during treatment are 4 mm right, 5 mm left, 7 mm anterior, and 6 mm posterior. For the rectum, values were 8 mm right, 8 mm left, 8 mm anterior, and 9 mm posterior. The greatest movement of the rectum occurred in the upper third. Conclusions: Contrast is no longer used in CT simulation. Assuming bony alignment, a nonuniform margin of 8 mm anteriorly, 9 mm posteriorly, and 8 mm left and right is recommended.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Assessment of Organ Motion in Postoperative Endometrial and Cervical Cancer Patients Treated With Intensity-Modulated Radiation Therapy

Purpose: Intensity-modulated radiation therapy (IMRT) may be useful to reduce toxicity in gynecologic cancer patients requiring postoperative pelvic irradiation. This study was undertaken to quantify vaginal wall organ motion during the course of postoperative pelvic irradiation using pelvic IMRT. Methods and Materials: Twenty-two consecutive patients treated with postoperative pelvic IMRT on helical tomotherapy had fiducial markers placed at the vaginal apex prior to simulation then daily megavoltage computed tomography (CT) scans for positioning. The daily positions of the fiducials were registered and measured in reference to the initial CT scan to quantify the degree of vaginal wall organ motion during the entire course of therapy. Results: The total motion of the fiducials center of mass (COM) was a median of 5.8 mm (range, 0.6-20.2 mm), and 95% of all COM positions fell within 15.7 mm of their original position. Directional margins of 3.1 mm along the right-left axis, 9.5 mm along the superoinferior axis, and of 12.1 mm along the anteroposterior axis encompassed the vaginal fiducials in 95% of treatments. Mean organ deformation for all patients was 3.9 mm, (range, 0-27.5 mm; standard deviation, 3.1 mm), with significant distortions of greater than 10 mm in 17% of secondary image sets. Conclusions: These data suggest a planning target volume margin of 16 mm will account for maximal organ motion in the majority of gynecologic patients undergoing postoperative pelvic IMRT, and it may be possible to incorporate directional motion into the planning target volume margin.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Spine Stereotactic Body Radiotherapy Utilizing Cone-Beam CT Image-Guidance With a Robotic Couch: Intrafraction Motion Analysis Accounting for all Six Degrees of Freedom

Purpose: To evaluate the residual setup error and intrafraction motion following kilovoltage cone-beam CT (CBCT) image guidance, for immobilized spine stereotactic body radiotherapy (SBRT) patients, with positioning corrected for in all six degrees of freedom. Methods and Materials: Analysis is based on 42 consecutive patients (48 thoracic and/or lumbar metastases) treated with a total of 106 fractions and 307 image registrations. Following initial setup, a CBCT was acquired for patient alignment and a pretreatment CBCT taken to verify shifts and determine the residual setup error, followed by a midtreatment and posttreatment CBCT image. For 13 single-fraction SBRT patients, two midtreatment CBCT images were obtained. Initially, a 1.5-mm and 1 Degree-Sign tolerance was used to reposition the patient following couch shifts which was subsequently reduced to 1 mm and 1 Degree-Sign degree after the first 10 patients. Results: Small positioning errors after the initial CBCT setup were observed, with 90% occurring within 1 mm and 97% within 1 Degree-Sign . In analyzing the impact of the time interval for verification imaging (10 {+-} 3 min) and subsequent image acquisitions (17 {+-} 4 min), the residual setup error was not significantly different (p > 0.05). A significant difference (p = 0.04) in the average three-dimensional intrafraction positional deviations favoring a more strict tolerance in translation (1 mm vs. 1.5 mm) was observed. The absolute intrafraction motion averaged over all patients and all directions along x, y, and z axis ({+-} SD) were 0.7 {+-} 0.5 mm and 0.5 {+-} 0.4 mm for the 1.5 mm and 1 mm tolerance, respectively. Based on a 1-mm and 1 Degree-Sign correction threshold, the target was localized to within 1.2 mm and 0.9 Degree-Sign with 95% confidence. Conclusion: Near-rigid body immobilization, intrafraction CBCT imaging approximately every 15-20 min, and strict repositioning thresholds in six degrees of freedom yields minimal intrafraction motion allowing for safe spine SBRT delivery.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Validating Fiducial Markers for Image-Guided Radiation Therapy for Accelerated Partial Breast Irradiation in Early-Stage Breast Cancer

Purpose: Image-guided radiation therapy (IGRT) may be beneficial for accelerated partial breast irradiation (APBI). The goal was to validate the use of intraparenchymal textured gold fiducials in patients receiving APBI. Methods and Materials: Twenty-six patients were enrolled on this prospective study that had three or four textured gold intraparenchymal fiducials placed at the periphery of the lumpectomy cavity and were treated with three-dimensional (3D) conformal APBI. Free-breathing four-dimensional computed tomography image sets were obtained pre- and posttreatment, as were daily online megavoltage (MV) orthogonal images. Intrafraction motion, variations in respiratory motion, and fiducial marker migration were calculated using the 3D coordinates of individual fiducials and a calculated center of mass (COM) of the fiducials. We also compared the relative position of the fiducial COM with the geometric center of the seroma. Results: There was less than 1 mm of intrafraction respiratory motion, variation in respiratory motion, or fiducial marker migration. The change in seroma position relative to the fiducial COM was 1 mm {+-} 1 mm. The average position of the geometric seroma relative to the fiducial COM pretreatment compared with posttreatment was 1 mm {+-} 1 mm. The largest daily variation in displacement when using bony landmark was in the anteroposterior direction and two standard deviations (SD) of this variation was 10 mm. The average variation in daily separation between the fiducial pairs from daily MV images was 3 mm {+-} 3 mm therefore 2 SD is 6 mm. Conclusion: Fiducial markers are stable throughout the course of APBI. Planning target volume margins when using bony landmarks should be 10 mm and can be reduced to 6 mm if using fiducials.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Tumor, Lymph Node, and Lymph Node-to-Tumor Displacements Over a Radiotherapy Series: Analysis of Interfraction and Intrafraction Variations Using Active Breathing Control (ABC) in Lung Cancer

Purpose: To estimate errors in soft tissue-based image guidance due to relative changes between primary tumor (PT) and affected lymph node (LN) position and volume, and to compare the results with bony anatomy-based displacements of PTs and LNs during radiotherapy of lung cancer. Methods and Materials: Weekly repeated breath-hold computed tomography scans were acquired in 17 lung cancer patients undergoing radiotherapy. PTs and affected LNs were manually contoured on all scans after rigid registration. Interfraction and intrafraction displacements in the centers of mass of PTs and LNs relative to bone, as well as LNs relative to PTs (LN-PT), were calculated. Results: The mean volume after 5 weeks was 65% for PTs and 63% for LNs. Systematic and random interfraction displacements were 2.6 to 4.6 mm and 2.7 to 2.9 mm, respectively, for PTs; 2.4 to 3.8 mm and 1.4 to 2.7 mm, respectively, for LNs; and 2.3 to 3.9 mm and 1.9 to 2.8 mm, respectively, for LN-PT. Systematic and random intrafraction displacements were less than 1 mm except in the superoinferior direction. Interfraction LN-PT displacements greater than 3 mm were observed in 67% of fractions and require a safety margin of 12 mm in the lateral direction, 11 mm in the anteroposterior direction, and 9 mm in the superoinferior direction. LN-PT displacements displayed significant time trends (p < 0.0001) and depended on the presence of pathoanatomic conditions of the ipsilateral lung, such as atelectasis. Conclusion: Interfraction LN-PT displacements were mostly systematic and comparable to bony anatomy-based displacements of PTs or LNs alone. Time trends, large volume changes, and the influence of pathoanatomic conditions underline the importance of soft tissue-based image guidance and the potential of plan adaptation.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Quantifying the Interfractional Displacement of the Gastroesophageal Junction During Radiation Therapy for Esophageal Cancer

Purpose: Accounting for interfractional changes in tumor location improves the accuracy of radiation treatment delivery. The purpose of this study was to quantify the interfractional displacement of the gastroesophageal junction (GEJ) based on standard treatment setup in patients with esophageal cancer undergoing radiation therapy. Methods and Materials: Free-breathing four-dimensional computed tomography (4D-CT) datasets were acquired weekly from 22 patients during treatment for esophageal adenocarcinoma. Scans were registered to baseline (simulation) 4D-CT scans by using bony landmarks. The distance between the center of the GEJ contour on the simulation scan and the mean location of GEJ centers on subsequent scans was used to assess changes in GEJ location between fractions; displacement was also correlated with clinical and respiratory variables. Results: The mean absolute random error was 1.69 mm (range, 0.11-4.11 mm) in the lateral direction, 1.87 mm (range, 0.51-4.09 mm) in the anterior-posterior (AP) direction, and 3.09 mm (range, 0.99-6.16 mm) in the superior-inferior (SI) direction. The mean absolute systemic GEJ displacement between fractions was 2.88 mm lateral ({>=}5 mm in 14%), mostly leftward; 2.90 mm ({>=}5 mm in 14%) AP, mostly anterior; and 6.77 mm ({>=}1 cm in 18%) SI, mostly inferior. Variations in tidal volume and diaphragmatic excursion during treatment correlated strongly with systematic SI GEJ displacement (r = 0.964, p < 0.0001; and r = 0.944, p < 0.0001, respectively) and moderately with systematic AP GEJ displacement (r = 0.678, p = 0.0005; r = 0.758, p < 0.0001, respectively). Systematic displacement in the inferior direction resulted in higher-than-intended doses ({>=}60 Gy) to the GEJ, with increased hot-spot to the adjacent stomach and lung base. Conclusion: We found large (>1-cm) interfractional displacements in the GEJ in the SI (especially inferior) direction that was not accounted for when skeletal alignment alone was used for patient positioning. Because systematic displacement in the SI direction had dosimetric impact and correlated with tidal volume, better accounting for depth of breathing is needed to reduce interfractional variability.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Intrafraction Variability and Deformation Quantification in the Breast

Purpose: To evaluate intrafraction variability and deformation of the lumpectomy cavity (LC), breast, and nearby organs. Methods and Materials: Sixteen left-sided postlumpectomy and 1 bilateral breast cancer cases underwent free-breathing CT (FBCT) and 10-phase 4-dimensional CT (4DCT). Deformable image registration was used for deformation analysis and contour propagation of breast, heart, lungs, and LC between end-exhale and end-inhale 4DCT phases. Respiration-induced motion was calculated via centroid analysis. Two planning target volumes (PTVs) were compared: PTV{sub FBCT} from the FBCT volume with an isotropic 10 mm expansion (5 mm excursion and 5 mm setup error) and PTV{sub 4DCT} generated from the union of 4DCT contours with isotropic 5 mm margin for setup error. Volume and geometry were evaluated via percent difference and bounding box analysis, respectively. Deformation correlations between breast/cavity, breast/lung, and breast/heart were evaluated. Associations were tested between cavity deformation and proximity to chest wall and breast surface. Results: Population-based 3-dimensional vector excursions were 2.5 ± 1.0 mm (range, 0.8-3.8 mm) for the cavity and 2.0 ± 0.8 mm (range, 0.7-3.0 mm) for the ipsilateral breast. Cavity excursion was predominantly in the anterior and superior directions (1.0 ± 0.8 mm and −1.8 ± 1.2 mm, respectively). Similarly, for all cases, LCs and ipsilateral breasts yielded median deformation values in the superior direction. For 14 of 17 patients, the LCs and breast interquartile ranges tended toward the anterior direction. The PTV{sub FBCT} was 51.5% ± 10.8% larger (P<.01) than PTV{sub 4DCT}. Bounding box analysis revealed that PTV{sub FBCT} was 9.8 ± 1.2 (lateral), 9.0 ± 2.2 (anterior–posterior), and 3.9 ± 1.8 (superior–inferior) mm larger than PTV{sub 4DCT}. Significant associations between breast and cavity deformation were found for 6 of 9 axes. No dependency was found between cavity deformation and proximity to chest wall or breast surface. Conclusions: Lumpectomy cavity and breast deformation and motion demonstrated large variability. A PTV{sub 4DCT} approach showed value in patient-specific margins, particularly if robust interfraction setup analysis can be performed.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Effect of MLC Leaf Width and PTV Margin on the Treatment Planning of Intensity-Modulated Stereotactic Radiosurgery (IMSRS) or Radiotherapy (IMSRT)

We studied the effect of MLC (multileaf collimator) leaf width and PTV (planning target volume) margin on treatment planning of intensity modulated stereotactic radiosurgery (IMSRS) or radiotherapy (IMSRT). Twelve patients previously treated with IMSRS/IMSRT were retrospectively planned with 5- and 3-mm MLC leaf widths and 3- and 2-mm PTV margins using the already contoured clinical target volume and critical structures. The same beam arrangement, planning parameters, and optimization method were used in each of the 4 plans for a given patient. Each plan was normalized so that the prescription dose covered at least 99% of the PTV. Plan indices - D{sub mean} (mean dose), conformity index (CI), V{sub 70} (volume receiving {>=} 70% of the prescription dose), and V{sub 50} (volume receiving {>=} 50% of the prescription dose) - were calculated from the dose-volume histograms (DVHs) of the PTV, normal tissue, and organs at risk (OARs). Hypothesis testing was performed on the mean ratios of plan indices to determine the statistical significance of the relative differences. The PTV was well covered for all plans, as no significant differences were observed for D{sub 95}, V{sub 95}, D{sub max}, D{sub min}, and D{sub mean} of the PTV. The irradiated volume was {approx}23% smaller when 2-mm instead of 3-mm PTV margin was used, but it was only reduced by {approx}6% when the MLC leaf width was reduced from 5 mm to 3 mm. For normal tissue and brainstem, V{sub 70}, V{sub 50}, and D{sub mean} were reduced more effectively by a decrease in MLC width, while D{sub mean} of optic nerve and chiasm were more sensitive to a change in PTV margin. The DVH statistics for the PTV and normal structures from the treatment plan with 5-mm MLC and 2-mm PTV margin were equal to those with 3-mm MLC and 3-mm PTV margin. PTV margin reduction is more effective in sparing the normal tissue and OARs than a reduction in MLC leaf width. For IMSRS, where highly accurate setup and small PTV margins are routinely employed, the use of 5-mm MLC is therefore less desirable.

61 RADIATION PROTECTION AND DOSIMETRY↗

Using kV-kV and CBCT imaging to evaluate rectal cancer patient position when treated prone on a newly available belly board

The goal of this work was to use daily kV-kV imaging and weekly cone-beam CT (CBCT) to evaluate rectal cancer patient position when treated on a new couch top belly board (BB). Quality assurance (QA) of the imaging system was conducted weekly to ensure proper performance. The positional uncertainty of the combined kV-kV image match and subsequent couch move was found to be no more than {+-} 1.0 mm. The average (1 SD) CBCT QA phantom match was anterior-posterior (AP) = -0.8 {+-} 0.2 mm, superior-inferior (SI) = 0.9 {+-} 0.2 mm, and left-right (LR) = -0.1 {+-} 0.1 mm. For treatment, a set of orthogonal kV-kV images were taken and a bony anatomy match performed online. Moves were made along each axis (AP, SI, and LR) and recorded for analysis. CBCT data were acquired once every 5 fractions for a total of 5 images per patient. The images were all taken after the couch move but before treatment. A 3-dimensional (3D-3D) bony anatomy auto-match was performed offline and the residual difference in position recorded for analysis. The average ({+-} 1 SD) move required from skin marks, calculated over all 375 fractions (15 patients Multiplication-Sign 25 fractions/patient), were AP = -2.6 {+-} 3.7 mm, SI = -0.3 {+-} 4.9 mm, and LR = 1.8 {+-} 4.5 mm. The average residual difference in patient position calculated from the weekly CBCT data (75 total) were AP = -1.7 {+-} 0.4 mm, SI = 1.1 {+-} 0.6 mm, and LR = -0.5 {+-} 0.2 mm. These results show that the BB does provide simple patient positioning that is accurate to within {+-} 2.0 mm when using online orthogonal kV-kV image matching of the pelvic bony anatomy.

61 RADIATION PROTECTION AND DOSIMETRY↗