Search NASA⌕ Search

SEARCH · Search NASA

Results for “Measurement techniques”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 721 records · Page 40

ZPPR-15 Criticality Measurements

A reference critical configuration was established for each phase of the ZPPR-15 experimental program. The reference critical configuration for each phase corresponds to a configuration in which the measured excess reactivity was adjusted to a standard set of reporting conditions with an average reactor temperature of 293 K, a zero interface gap and all operational control rods parked 30 inches from the axial centerline of the core. The ZPPR staff published the measured excess reactivity and the statistical uncertainty in the measurement. In reality, the published uncertainty for each reference critical configuration is only a small component of the total uncertainty for that configuration. Additional uncertainties related measurement technique, configuration geometry and material compositions exist. The geometry and material composition uncertainties are the dominant uncertainties for ZPPR-15. A full uncertainty analysis was performed for each ZPPR-15 reference critical configuration. The significant uncertainties related to measurement technique, configuration geometry and material compositions were quantified, and a total uncertainty was derived for each reference critical configuration. The ZPPR-15 experimental records were used to create detailed as-built Monte Carlo models for the reference critical configurations established in ZPPR-15A loading 15, ZPPR-15B loading 88, ZPPR-15C loading 166 and ZPPR-15D loading 185. The as-built models neglect the small, non-uniform gap between matrix halves at full closure, any structures outside the matrix tubes and minor components, e.g., impurities, in some materials. The biases associated with the neglected items were quantified. The experimental value of keff and its associated uncertainty for each reference critical configuration were adjusted to account for biases introduced by items that are neglected in the as-built model for that configuration.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Workshop report: Velocity coupling

Velocity coupled combustion instability and related combustion instability topics were considered. The knowledge of velocity coupled combustion instability was assessed; the state of the art of velocity coupled measurement techniques was determined; and particularly laboratory devices or T burner related devices; recommendations were made on how to improve the state of knowledge on velocity coupled combustion instability. Test conditions for a round robin of velocity coupled response measurement techniques were established.

Beckstead, M. W.↗

An investigation of fluid flow during induction stroke of a water analog model of an IC engine using an innovative optical velocimetry concept: LIPA

Optical measurements on an axisymmetrical quartz component engine research model were made to evaluate the flow field encountered during induction. The measurement technique is LIPA (Laser Induced Photochemical Anemometry), a non-intrusive velocimetry concept that provides an investigator of fluid flow with a tool to attain planar information about three-dimensional velocity and vorticity vectors in a single measurement step. The goal of this investigation is to further develop this measurement technique and apply it to study the induction stroke of a water analog model of a four-stroke internal combustion engine. The research conducted in the water analog model is a fundamental scientific inquiry into the flow fields that develop in the induction stroke of an engine at idling engine speeds. As this is the first investigation of its kind using LIPA technique, our goal has been to quantify, in a preliminary manner, the flow field features that develop during the intake stroke. In the process a more comprehensive understanding of the flow field features was developed, and tied to the quantification. The study evaluated the flow field of the intake stroke by estimating fields of velocity and vorticity. On the basis of these data, information about fluid dynamics during induction at engine speeds of 10, 20, and 30 RPM (corresponding to 170, 340, and 510 RPM respectively, when air is the flowing medium) for three different valve lifts was obtained. The overall development of the flow field, its energy content (kinetic, fluctuation) for the different settings of the engine parameters, vorticity information, and cyclic variations have been quantified. These have been discussed in terms of mixing performance.

Stier, Bernd↗

Airdata calibration techniques for measuring atmospheric wind profiles

The research airdata system of an instrumented F-104 aircraft has been calibrated to measure winds aloft in support of the Space Shuttle wind measurement investigation at the National Aeronautics and Space Administration Ames Research Center Dryden Flight Research Facility. For this investigation, wind measurement accuracies comparable to those obtained from Jimsphere balloons were desired. This required an airdata calibration more accurate than needed for most aircraft research programs. The F-104 aircraft was equipped with a research pilot-static noseboom with integral angle-of-attack and flank angle-of-attack vanes and a ring-laser-gyro inertial reference unit. Tower fly-bys and radar acceleration-decelerations were used to calibrate Mach number and total temperature. Angle of attack and angle of side slip were calibrated with a trajectory reconstruction technique using a multiple-state linear Kalman filter. The F-104 aircrat and instrumentation configuration, flight test maneuvers, data corrections, calibration techniques, and resulting calibrations and data repeatability are presented. Recommendations for future airdata systems on aircraft used to measure winds aloft are also given.

Haering, Edward A., Jr.↗

High temperature Seebeck coefficient metrology

We present an overview of the challenges and practices of thermoelectric metrology on bulk materials at high temperature (300 to 1300 K). The Seebeck coefficient, when combined with thermal and electrical conductivity, is an essential property measurement for evaluating the potential performance of novel thermoelectric materials. However, there is some question as to which measurement technique(s) provides the most accurate determination of the Seebeck coefficient at high temperature. This has led to the implementation of nonideal practices that have further complicated the confirmation of reported high ZT materials. To ensure meaningful interlaboratory comparison of data, thermoelectric measurements must be reliable, accurate, and consistent. This article will summarize and compare the relevant measurement techniques and apparatus designs required to effectively manage uncertainty, while also providing a reference resource of previous advances in high temperature thermoelectric metrology.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Core-drilling technique for in-situ stress evaluation in concrete structures

SummaryFor assessing the existing stresses in distressed reinforced concrete/prestressed concrete structures, the concrete core-drilling technique can be used. This core-drilling technique is a stress measurement technique in which a small core is drilled on the structure and the strain perturbations around the core are measured by instrumenting strain gages aligned in the same direction. Laboratory studies were conducted to evaluate the reliability of this concrete core-drilling technique. Calibration coefficients were evaluated experimentally for the used gage length, location, and configuration. Comparison was also made with coefficients evaluated theoretically. This technique is suitable for prestressed concrete girders where girders are prestressed in one direction (longitudinally). Also in reinforced concrete members like columns, compression zones of beams on the major bending axis (along the span) can be evaluated for their in-situ stresses. This concrete core-drilling technique can be used to determine the in-situ stress with enhanced sensitivity in “in-service” prestressed concrete structures.

36 MATERIALS SCIENCE↗

A technique for measuring the sea water optical parameters with a dedicated laser beam and a multi-PMT optical module

The KM3NeT research infrastructure will be a deep sea multidisciplinary observatory in the Mediterranean Sea housing a neutrino telescope. Accurate knowledge of the optical properties of the sea water is important for the performance evaluation of the telescope. In this work we describe a technique for the evaluation of the parameters describing the scattering characteristics of the sea water using one multi-PMT optical module that detects scattered optical photons which are emitted from a laser. Our results show that we are able to determine these parameters with satisfying precision and are able to resolve the scattering length values with less than half a meter accuracy.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Radon emanation rate measurements using liquid scintillation counting

This article describes a radon emanation measurement technique using liquid scintillator counting. A model for radon loading and transport is described, along with its calibration. Detector background and blank have been studied and quantified. The Minimal detectable activity has been determined for the counting setup using a toy Monte Carlo simulation. Here, the measurement technique is validated using a butyl rubber sample previously used for cross-calibration between different radon counting facilities.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Characterization of multiterminal tandem photovoltaic devices and their subcell coupling

Three-terminal (3T) and four-terminal (4T) tandem photovoltaic (PV) devices using various materials have been increasingly reported in the literature, but measurement standards are lacking. Here, multiterminal devices measured as functions of two load variables are characterized unambiguously as functions of three device voltages or currents on hexagonal plots. We demonstrate these measurement techniques using two GaInP/GaAs tandem solar cells, with a middle contact between the two subcells, as example 3T devices with both series-connected and reverse-connected subcells. Coupling mechanisms between the subcells are quantified within the context of a simple equivalent optoelectronic circuit. Electrical and optical coupling mechanisms are most clearly revealed using coupled dark measurements. These measurements are sensitive enough to observe very small luminescent coupling from the bottom subcell to the top subcell in the prototype 3T device. Quick simplified measurement techniques are also discussed within the context of the complete characterization.

14 SOLAR ENERGY↗

Measuring the Exciton Binding Energy: Learning from a Decade of Measurements on Halide Perovskites and Transition Metal Dichalcogenides

The exciton binding energy ( E b ) is a key parameter that governs the physics of many optoelectronic devices. At their best, trustworthy and precise measurements of E b challenge theoreticians to refine models, are a driving force in advancing the understanding of a material system, and lead to efficient device design. At their worst, inaccurate E b measurements lead theoreticians astray, sow confusion within the research community, and hinder device improvements by leading to poor designs. Here, this review article seeks to highlight the pros and cons of different measurement techniques used to determine E b , namely, temperature‐dependent photoluminescence, resolving Rydberg states, electroabsorption, magnetoabsorption, scanning tunneling spectroscopy, and fitting the optical absorption. Due to numerous conflicting E b values reported for halide perovskites (HP) and transition metal dichalcogenides (TMDC) monolayers, an emphasis is placed on highlighting these measurements in an attempt to reconcile the variance between different measurement techniques. It is argued that the experiments with the clearest indicators are in agreement on the following values: ≈350–450 meV for TMDC monolayers between SiO 2 and vacuum, ≈150–200 meV for hBN‐encapsulated TMDC monolayers, ≈200–300 meV for common lead‐iodide 2D HPs, and ≈10 meV for methylammonium lead iodide.

36 MATERIALS SCIENCE↗

Measurement Issues In Pulsed Laser Propulsion

Various measurement techniques have been used throughout the over 40-year history of laser propulsion. Often, these approaches suffered from inconsistencies in definitions of the key parameters that define the physics of laser ablation impulse generation. Such parameters include, but are not limited to the pulse energy, spot area, imparted impulse, and ablated mass. The limits and characteristics of common measurement techniques in each of these areas will be explored as they relate to laser propulsion. The idea of establishing some standardization system for laser propulsion data is introduced in this paper, so that reported results may be considered and studied by the general community with more certain understanding of particular merits and limitations. In particular, it is the intention to propose a minimum set of requirements a literature study should meet. Some international standards for measurements are already published, but modifications or revisions of such standards may be necessary for application to laser ablation propulsion. Issues relating to development of standards will be discussed, as well as some examples of specific experimental circumstances in which standardization would have prevented misinterpretation or misuse of past data.

36 MATERIALS SCIENCE↗

Dielectric properties measurement of substrate and support materials

In this paper a fast and straightforward waveguide measurement technique is described for the determination of the dielectric constant and loss tangent of many commercially available materials. These dielectric materials include Cuflon, Teflon, Arlon's polyimides, Lockheed's ceramic foams, and Rogers Duroid materials. The effective dielectric constant and loss tangent of Hexsel's honeycomb material is also measured by this method and is compared to the predicted data obtained using the volume averaging theory. The accuracy and other features of this measurement technique are also discussed.

Wu, Te-Kao↗

Spatio-temporal structure of a petawatt femtosecond laser beam

Abstract The development of optical metrology suited to ultrafast lasers has played a key role in the progress of these light sources in the last few decades. Measurement techniques providing the complete E -field of ultrashort laser beams in both time and space are now being developed. Yet, they had so far not been applied to the most powerful ultrashort lasers, which reach the PetaWatt range by pushing the chirped pulse amplification (CPA) scheme to its present technical limits. This situation left doubts on their actual performance, and in particular on the peak intensity they can reach at focus. In this article we present the first complete spatio-temporal characterization of a PetaWatt femtosecond laser operating at full intensity, the BELLA laser, using two recently-developed independent measurement techniques. Our results demonstrate that, with adequate optimization, the CPA technique is still suitable at these extreme scales, i.e. it is not inherently limited by spatio-temporal couplings. We also show how these measurements provide unprecedented insight into the physics and operation regime of such laser systems.

47 OTHER INSTRUMENTATION↗

Measurement of the energy distribution of an intense electron beam in an external magnetic field

An energy analyzer device has been developed which utilizes a series of stacked foils and Rogowski current monitors to the measure time resolved current of an intense electron beam. The energy distribution of the electron beam is unfolded from measured current ratios using computer simulations. This device is particularly useful where electron beams are guided by external magnetic fields which may make other electron energy measurement techniques difficult. This technique was used to determine the energy distribution of a 550 keV, 95 kA electron beam as it propagates in the gas mixture of a high power KrF laser. The resulting energy distributions at various depths in the gas are in agreement with three-dimensional particle-in-cell simulations providing confidence in the measurement technique.

43 PARTICLE ACCELERATORS↗

Noncontacting Laser Inspection System for Dimensional Profiling of Space Application Thermal Barriers

A noncontacting, two-dimensional (2-D) laser inspection system has been designed and implemented to dimensionally profile thermal barriers being developed for space vehicle applications. In a vehicle as-installed state, thermal barriers are commonly compressed between load sensitive thermal protection system (TPS) panels to prevent hot gas ingestion through the panel interface during flight. Loads required to compress the thermal barriers are functions of their construction, as well as their dimensional characteristics relative to the gaps in which they are installed. Excessive loads during a mission could damage surrounding TPS panels and have catastrophic consequences. As such, accurate dimensional profiling of thermal barriers prior to use is important. Due to the compliant nature of the thermal barriers, traditional contact measurement techniques (e.g., calipers and micrometers) are subjective and introduce significant error and variability into collected dimensional data. Implementation of a laser inspection system significantly enhanced the method by which thermal barriers are dimensionally profiled, and improved the accuracy and repeatability of collected data. A statistical design of experiments study comparing laser inspection and manual caliper measurement techniques verified these findings.

Taylor, Shawn C.↗

Accuracy of cranial coplanar beam therapy using an oblique, stereoscopic x-ray image guidance system

A system for measuring two-dimensional (2D) dose distributions in orthogonal anatomical planes in the cranium was developed and used to evaluate the accuracy of coplanar conformal therapy using ExacTrac image guidance. Dose distributions were measured in the axial, sagittal, and coronal planes using a CIRS (Computerized Imaging Reference Systems, Inc.) anthropomorphic head phantom with a custom internal film cassette. Sections of radiographic Kodak EDR2 film were cut, processed, and digitized using custom templates. Spatial and dosimetric accuracy and precision of the film system were assessed. BrainScan planned a coplanar-beam treatment to conformally irradiate a 2-cm-diameterx2-cm-long cylindrical planning target volume. Prior to delivery, phantom misalignments were imposed in combinations of {+-}8 mm offsets in each of the principal directions. ExacTrac x-ray correction was applied until the phantom was within an acceptance criteria of 1 mm/1 deg. (first two measurement sets) or 0.4 mm/0.4 deg. (last two measurement sets). Measured dose distributions from film were registered to the treatment plan dose calculations and compared. Alignment errors, displacement between midpoints of planned and measured 70% isodose contours ({delta}c), and positional errors of the 80% isodose line were evaluated using 49 2D film measurements (98 profiles). Comparison of common, but independent measurements of {delta}c showed that systematic errors in the measurement technique were 0.2 mm or less along all three anatomical axes and that random error averaged ({sigma}{+-}{sigma}{sub {sigma}}) 0.29{+-}0.06 mm for the acceptance criteria of 1 mm/1 deg. and 0.15{+-}0.02 mm for the acceptance criteria of 0.4 mm/0.4 deg. . The latter was consistent with independent estimates that showed the precision of the measurement system was 0.3 mm (2{sigma}). Values of {delta}c were as great as 0.9, 0.3, and 1.0 mm along the P-A, R-L, and I-S axes, respectively. Variations in {delta}c along the P-A axis were correlated to misalignments between laser isocenter and radiation isocenter as documented by daily clinical Lutz tests. Based on results of comparisons of measured with calculated positions of the 80% dose lines along the major anatomical axes, a 1.25, 1.0, and 1.0 mm (0.75, 0.5, and 0.25 mm) gross tumor volume (GTV)-planning target volume (PTV) margin to account for delivery error would be appropriate for the P-A, R-L, and I-S axes, respectively, for an acceptance criteria of 1 mm/1 deg. (0.4 mm/0.4 deg. ). It typically took 2 (3) ExacTrac x-ray image sets to achieve and verify acceptance criteria of 1 mm/1 deg. (0.4 mm/0.4 deg. ). Our results demonstrated a measurement technique using a CIRS anthropomorphic head phantom with a modified film cassette, radiographic film (Kodak EDR2) with a custom film cutting template, and film dosimetry software has been developed and successfully applied to our clinic. It is recommended that a third party offer this service. Our goal of achieving accuracy of delivery of 1 mm or better in each of the three major anatomical axes was almost, but not quite achieved, not because of the accuracy of the image guidance system, but likely due to inaccuracy of laser isocenter and other systematic errors.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

The Muon g-2 experiment at Fermilab

Precision measurements of the anomalous magnetic moment of the muon a are a stringent test of the Standard Model. The last measurement of a at Brookhaven National Laboratory (BNL) diers from the Standard Model prediction by 3-4: a possible indication of new physics. A successor to that experi- ment has been constructed at Fermilab, with the aim of reducing the experimental uncertainty by a factor of four to 140 ppb. The measurement technique continues to use the storage ring concept from BNL, with muons circulating in a highly uni- form magnetic dipole eld. The spin precession frequency is extracted by analysing the modulation of the rate of higher-energy positrons from muon decays, which are detected by 24 calorimeters around the inside of the ring. Compared to the previous experiment, signicant improvements have been made in the areas of muon beam preparation, storage ring hardware, eld measuring equipment, and detector and electronics systems. In these proceedings, I report on the status of the experiment as of June 2018, presenting an overview of the experiment's progress, some initial data from the rst run, and the anticipated timeline for a new result.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Experience with Aero- and Fluid-Dynamic Testing for Engineering and CFD Validation

Ever since computations have been used to simulate aerodynamics the need to ensure that the computations adequately represent real life has followed. Many experiments have been performed specifically for validation and as computational methods have improved, so have the validation experiments. Validation is also a moving target because computational methods improve requiring validation for the new aspect of flow physics that the computations aim to capture. Concurrently, new measurement techniques are being developed that can help capture more detailed flow features pressure sensitive paint (PSP) and particle image velocimetry (PIV) come to mind. This paper will present various wind-tunnel tests the author has been involved with and how they were used for validation of various kinds of CFD. A particular focus is the application of advanced measurement techniques to flow fields (and geometries) that had proven to be difficult to predict computationally. Many of these difficult flow problems arose from engineering and development problems that needed to be solved for a particular vehicle or research program. In some cases the experiments required to solve the engineering problems were refined to provide valuable CFD validation data in addition to the primary engineering data. All of these experiments have provided physical insight and validation data for a wide range of aerodynamic and acoustic phenomena for vehicles ranging from tractor-trailers to crewed spacecraft.

experiment↗