At least 721 records · Page 40

Silicon Nitride Plates for Turbine Blade Application: FEA and NDE Assessment

Engine manufacturers are continually attempting to improve the performance and the overall efficiency of internal combustion engines. The thermal efficiency is typically improved by raising the operating temperature of essential engine components in the combustion area. This reduces the heat loss to a cooling system and allows a greater portion of the heat to be used for propulsion. Further improvements can be achieved by diverting part of the air from the compressor, which would have been used in the combustor for combustion purposes, into the turbine components. Such a process is called active cooling. Increasing the operating temperature, decreasing the cooling air, or both can improve the efficiency of the engine. Furthermore, lightweight, strong, tough hightemperature materials are required to complement efficiency improvement for nextgeneration gas turbine engines that can operate with minimum cooling. Because of their low-density, high-temperature strength, and thermal conductivity, ceramics are being investigated as potential materials for replacing ordinary metals that are currently used for engine hot section components. Ceramic structures can withstand higher operating temperatures and other harsh environmental factors. In addition, their low densities relative to metals helps condense component mass (ref. 1). The objectives of this program at the NASA Glenn Research Center are to develop manufacturing technology, a thermal barrier coating/environmental barrier coating (TBC/EBC), and an analytical modeling capability to predict thermomechanical stresses, and to do minimal burner rig tests of silicon nitride (Si3N4) and SiC/SiC turbine nozzle vanes under simulated engine conditions. Furthermore, and in support of the latter objectives, an optimization exercise using finite element analysis and nondestructive evaluation (NDE) was carried out to characterize and evaluate silicon nitride plates with cooling channels.

Abdul-Aziz, Ali↗

Nondestructive Crack Detection in a Fuel System Component

The presentation examines the background and objective of nondestructive crack detection, flow control valve assembly and poppet post flight evaluation, poppet properties. magnetic property characterization of lab data, NDE, eddy current inspection, simulation, eddy current criteria, poppet cycle testing and NDE criteria, and the use of ultrasonic surface wave for crack detection.

Koshti, Ajay↗

Overview of Nondestructive Evaluation Capabilities at NASA MSFC

Nondestructive evaluation (NDE) methods examine material integrity without impairing its usefulness. The NDE team at NASA Marshall Space Flight Center (MSFC) in Huntsville, Alabama is responsible for applying existing methods to new hardware designs and material systems, probability of detection studies to quantify detection capabilities, overseeing NDE requirements for flight hardware, inspecting development articles and flight hardware, engineering support for failure investigations, and investigating emerging NDE methods. NASA MSFC has been on the cutting edge of developing new NDE techniques, first for the space shuttle, then for composite structures, and most recently for additive manufacturing (AM). Standard in-house inspection capabilities include eddy current, magnetic particle, liquid penetrant, ultrasonic, and radiographic testing (including computed tomography). Other advanced inspection capabilities include infrared flash thermography, shearography, acoustic emission, and microwave/millimeter wave testing. Some recent research studies include AM probability of detection testing, investigating in-situ process monitoring methods for AM, and correlating the NDE response of true fatigue cracks with artificial notches.

nondestructive evaluation↗

Characterization of direct readout Si:Sb and Si:Ga infrared detector arrays for space-based astronomy

Preliminary test results from the evaluation of Si:Sb and Si:Ga 58 x 62-element infrared detector arrays are presented. These devices are being characterized under background conditions and readout rates representative of operation in orbiting, crogenically-cooled infrared observatories. The arrays are hybridized to silicon direct-readout multiplexers which allow random-access and nondestructive readout. Array performance optimization is being conducted with a flexible microcomputer-based drive and readoaut electronics system. Preliminary Si:Sb measurements indicate a sense node capacitance of 0.06 pF, peak (28-micron) responsivity above 3 A/W at 2V bias, read noise of 130 rms e(-), dark current approximately 10 e(-)/s, and a well capacity greater than 10 to the 5th e(-). The limited test data available on the performance of the Si:Ga array are also discussed.

Mckelvey, Mark E.↗

Nondestructive Determination of Heat/Fire Damage to Polymer- Matrix Composites Using Obliquely Insonified Ultrasonic Waves

Heat and fire damage to composite structures cause loss of strength that cannot be detected by current NDE methods unless physical damage occurs. Further, there is a lack of fundamental understanding of the mechanism of damage from thermal exposure of organic matrix composites to elevated temperatures. Information compiled from field reports and lab experiments increasingly suggests that there is material degradation and it is not necessarily involved with the introduction of physical defects. In recent years, various researchers examined the potential to identifying thermal degradation to organic matrix composites prior to delamination. The methods that were used include: ultrasonics, backscattered X-ray, eddy current, thermography, drift and LPF spectroscopies, acousto-ultrasonics and hardness testing. None of these methods were able to correlate NDE results with loss of mechanical properties.

polymer-matrix composite fire damage NDE nondestru↗

Performance Improvement of Friction Stir Welds by Better Surface Finish

The as-welded friction stir weld has a cross section that may act as a stress concentrator. The geometry associated with the stress concentration may reduce the weld strength and it makes the weld challenging to inspect with ultrasound. In some cases, the geometry leads to false positive nondestructive evaluation (NDE) indications and, in many cases, it requires manual blending to facilitate the inspection. This study will measure the stress concentration effect and develop an improved phased array ultrasound testing (PAUT) technique for friction stir welding. Post-welding, the friction stir weld (FSW) tool would be fitted with an end mill that would machine the weld smooth, trimmed shaved. This would eliminate the need for manual weld preparation for ultrasonic inspections. Manual surface preparation is a hand operation that varies widely depending on the person preparing the welds. Shaving is a process that can be automated and tightly controlled.

Russell, Sam↗

Applicability of a Crack-Detection System for Use in Rotor Disk Spin Test Experiments Being Evaluated

Engine makers and aviation safety government institutions continue to have a strong interest in monitoring the health of rotating components in aircraft engines to improve safety and to lower maintenance costs. To prevent catastrophic failure (burst) of the engine, they use nondestructive evaluation (NDE) and major overhauls for periodic inspections to discover any cracks that might have formed. The lowest cost fluorescent penetrant inspection NDE technique can fail to disclose cracks that are tightly closed during rest or that are below the surface. The NDE eddy current system is more effective at detecting both crack types, but it requires careful setup and operation and only a small portion of the disk can be practically inspected. So that sensor systems can sustain normal function in a severe environment, health-monitoring systems require the sensor system to transmit a signal if a crack detected in the component is above a predetermined length (but below the length that would lead to failure) and lastly to act neutrally upon the overall performance of the engine system and not interfere with engine maintenance operations. Therefore, more reliable diagnostic tools and high-level techniques for detecting damage and monitoring the health of rotating components are very essential in maintaining engine safety and reliability and in assessing life.

Abdul-Aziz, Ali↗

Nondestructive evaluation of adhesive bond strength using the stress wave factor technique

Acousto-ultrasonic nondestructive evaluation has been conducted to evaluate the adhesive bond strength between rubber and steel plates using the stress wave factor (SWF) measurement technique. Specimens with different bond strength were manufactured and tested using the SWF technique. Two approaches were used to define the SWF. One approach defines the SWF as the signal energy and the other approach defines the SWF as the square root of the zero moment of the frequency spectrum of the received signal. The strength of the rubber-steel adhesive joint was then evaluated using the destructive peel strength test method. It was observed that in both approaches higher values of the SWF measurements correspond to higher values of the peel strength test data. Therefore, these results show that the stress wave factor technique has the potential of being used in quality assurance of the adhesive bond strength between rubber and steel substrates.

Dos Reis, Henrique L. M.↗

Nondestructive evaluation of Shuttle Columbia tiles

The NDE of Orbiter Vehicle-102 tile bonds, performed in August 1991, is described. The evaluation was carried out in order to help NASA develop fast, reliable methods to diagnose problems in tile bonding other than the present 'pull' and 'wiggle' tests. The NDE did not find any indication of bond problems, and all bonds were classified as 'nominal'. The feasibility of using NDE techniques in a dynamic, real-world environment without interfering with Shuttle rework schedules is shown. The data will be useful in verifying analytical models of tile behavior developed at the University of Central Florida. The need for a tile test bed containing known tile misbonds is suggested.

Davis, Richard M.↗

Ceramic applications in turbine engines

Ceramic material characterization and testing of ceramic nozzle vanes, turbine tip shrouds, and regenerators disks at 36 C above the baseline engine TIT and the design, analysis, fabrication and development activities are described. The design of ceramic components for the next generation engine to be operated at 2070 F was completed. Coupons simulating the critical 2070 F rotor blade was hot spin tested for failure with sufficient margin to quality sintered silicon nitride and sintered silicon carbide, validating both the attachment design and finite element strength. Progress made in increasing strength, minimizing variability, and developing nondestructive evaluation techniques is reported.

Hudson, M. S.↗

Structural analysis of an NDE-inspected carbon-carbon component

In this research, it is demonstrated that the integration of nondestructive evaluation with the finite element method (a quantitative NDE/FEM approach) can be used for analysis and behavior prediction of advanced materials, such as fiber composites, after processing and during in-service testing. First, stress, strain, and energy data were calculated by the finite element method for square plates with a 10 percent difference in the material properties between specified segments, i.e., between the center and the outside section or between two halves of the plate. This demonstrated the efficiency of the method in predicting variations in the structural behavior based on small material property differences. Then, finite element analyses and actual axial compression tests were performed on a Space Shuttle brake stator made from woven carbon-carbon composites. The material properties used in the numerical modeling of the stator were previously characterized at a large number of points on the component by quantitative NDE-procedures, i.e., ultrasonics and radiography. The results from the experimental compressive loading tests were used to verify the NDE/FEM results. Good agreement was found for most parameters.

Striz, A. G.↗

Real time acousto-ultrasonic NDE technique for monitoring damage in ceramic composites under dynamic loads

Research effort was directed towards developing a near real-time, acousto-ultrasonic (AU), nondestructive evaluation (NDE) tool to study the failure mechanisms of ceramic composites. Progression of damage is monitored in real-time by observing the changes in the received AU signal during the actual test. During the real-time AU test, the AU signals are generated and received by the AU transducers attached to the specimen while it is being subjected to increasing quasi-static loads or cyclic loads (10 Hz, R = 1.0). The received AU signals for 64 successive pulses were gated in the time domain (T = 40.96 micro sec) and then averaged every second over ten load cycles and stored in a computer file during fatigue tests. These averaged gated signals are representative of the damage state of the specimen at that point of its fatigue life. This is also the first major attempt in the development and application of real-time AU for continuously monitoring damage accumulation during fatigue without interrupting the test. The present work has verified the capability of the AU technique to assess the damage state in silicon carbide/calcium aluminosilicate (SiC/CAS) and silicon carbide/ magnesium aluminosilicate (SiC/MAS) ceramic composites. Continuous monitoring of damage initiation and progression under quasi-static ramp loading in tension to failure of unidirectional and cross-ply SiC/CAS and quasi-isotropic SiC/MAS ceramic composite specimens at room temperature was accomplished using near real-time AU parameters. The AU technique was shown to be able to detect the stress levels for the onset and saturation of matrix cracks, respectively. The critical cracking stress level is used as a design stress for brittle matrix composites operating at elevated temperatures. The AU technique has found that the critical cracking stress level is 10-15% below the level presently obtained for design purposes from analytical models. An acousto-ultrasonic stress-strain response (AUSSR) model for unidirectional and cross-ply ceramic composites was formulated. The AUSSR model predicts the strain response to increasing stress levels using real-time AU data and classical laminated plate theory. The Weibull parameters of the AUSSR model are used to calculate the design stress for thermo-structural applications. Real-time AU together with the AUSSR model was used to study the failure mechanisms of SiC/CAS ceramic composites under static and fatigue loading. An S-N curve was generated for a cross-ply SiC/CAS ceramic composite material. The AU results are corroborated and complemented by other NDE techniques, namely, in-situ optical microscope video recordings and edge replication.

Tiwari, Anil↗

Assessing Reliability of NDE Flaw Detection Using Smaller Number of Demonstration Data Points

The paper provides an engineering analysis approach for assessing reliability of NDE flaw detection using smaller number of demonstration data points. It explores dependence of probability of detection (POD), probability of false positive (POF), on contrast-to-noise ratio, and net decision threshold-to-noise ratio in a simulated data; and draws some generically applicable inferences to devise the approach. ASTM nondestructive evaluation standards provide requirements on signal-to-noise ratio and/or contrast-to-noise ratio in order to provide reliable flaw detection and limit false positive calls. POD analysis of inspection test data results in an estimated flaw size, denoted by 𝑎90/95. This flaw size has 90% POD and minimum 95% confidence. POF is also estimated in the analysis. POD demonstration requires specimens with flaws of known size. In many situations, it is very expensive to produce the large number of flaws required for the POD analysis. In some situations, only real flaws can truly represent the flaws for demonstration. Real flaws of correct size and location in part configuration specimen may be difficult to produce, if not impossible. Here, an engineering analysis approach is devised using simulation to assess reliability of NDE technique when a limited number of flaws are available for demonstration. In this simulation, a technique is considered reliable, if it provides flaw detectability size equal to or better than the theoretical 𝑎90𝑡ℎ used in simulation and also provides a POF less than or equal to a chosen value. The paper uses simulated signal response versus flaw size data to devise the approach. Linear correlation is used between the signal response data and flaw size. POD software mh1823 uses generalized linear model (GLM) in POD analysis after transforming the flaw size and signal response, if needed, using logarithm. Therefore, this approach is in agreement with the linear signal correlation used in mh1823. Using the POD analysis of data, generic conditions on contrast-to-noise ratio and net decision threshold-to-noise ratio are derived for reliable flaw detection. In order to assess technique reliability using the engineering approach, signal response-to-flaw size correlation about the flaw size of concern is needed. In addition, measurement of noise is also needed. If the technique meets the above requirements, assumption of linear signal-to-flaw size correlation and conditions on noise, then the technique can be assessed using this analysis as it fits the underlying POD model used here. The approach is conservative and is designed to provide a larger flaw size compared to the POD approach. Such NDE technique assessment approach, although, not as rigorous as POD, can be cost effective if the larger flaw size can be tolerated. Typically, this is a situation for all quality control NDE inspections. Here, an NDE technique needs to be reliable and 𝑎90/95 is not estimated, but the assessed flaw size is assumed to be larger than the unknown a90 due to conservative factors or margins. Applicability of the approach for assessing reliability of flaw detection in x-ray radiography and 2D imaging in general is also explored.

Koshti, Ajay M.↗

Nondestructive determination of mechanical properties

The sensitivity of the velocity of ultrasonic waves to the elasticity of the materials (acousto-elastic constant - AEC) as controlled by the microstructure of the materials was examined experimentally. Rolled-plate specimens of five different Al alloys were subjected to tensile tests while being monitored for the velocity change of a 10 MHz longitudinal wave as a function of the applied tensile stress. The acoustic propagation velocity was measured perpendicularly to the stress. Determinations were made of the yield strength and the hardnesses of the specimens. Samples of the plate materials examined microscopically to characterize the solid phases. The AECs varied linearly with the percentage of solid solution phase of the alloys. The trend for strain-hardened samples was, however, opposite from that in the precipitation-hardened alloys. The results underscore the necessity of considering the microstructural dependencies of the AECs when using ultrasonic NDE methods, and also opened the potential of determining some mechanical properties with NDE techniques.

Schneider, E.↗

Deflection resistance indicator

Instrument for nondestructively measuring compression resistance of spray foam used as thermal insulation was developed. Cylindrical indicator has probe with coil spring to provide force and indicating dial. Probe is manually pressed against area to be tested until complete foot area contacts foam surfaces.

Massey, H. S.↗

Effects of surface chemistry on hot corrosion life

Burner rig tests were conducted under the following conditions: 900 C, hourly thermal cycling, 0.5 ppm sodium as MaCl in the gas stream, velocity 0.3 Mach. The alloys are Udiment 700, Rene 80, uncoated and with RT21, Codep, or NiCoCrAlY coatings. These tests were completed for specimens in the as-processed condition and after aging at 1100 C in oxidizing or inert evnivronments for time up to 600 hours. Coil inductance changes used for periodic nondestructive inspection of specimens were useful in following the course of corrosion. Typical sulfidation was observed in all cases, structurally similar to that observed for service-run turbine components. Aging at cuased a severe decrease in hot corrosion life of RT21 and Codep coatings and a significant but less decrease in the life of the NiCoCrAlY coating. The extent of these decreases was much greater for all three coatings on U700 substrates than on Rene 80 substrates. Coating/substrate interdiffusion rather than by surface oxidation.

Fryxell, R. E.↗

Reliably Detectable Flaw Size for NDE Methods that Use Calibration

Probability of detection (POD) analysis is used in assessing reliably detectable flaw size in nondestructive evaluation (NDE). MIL-HDBK-1823 and associated mh1823 POD software gives most common methods of POD analysis. In this paper, POD analysis is applied to an NDE method, such as eddy current testing, where calibration is used. NDE calibration standards have known size artificial flaws such as electro-discharge machined (EDM) notches and flat bottom hole (FBH) reflectors which are used to set instrument sensitivity for detection of real flaws. Real flaws such as cracks and crack-like flaws are desired to be detected using these NDE methods. A reliably detectable crack size is required for safe life analysis of fracture critical parts. Therefore, it is important to correlate signal responses from real flaws with signal responses form artificial flaws used in calibration process to determine reliably detectable flaw size.

Koshti, Ajay M.↗

Measuring Tension in Transistor Suspensions

Vibration analyis is nondestructive and noninvasive. Transistor isolated from heat (or cold) of surroundings by filament suspension. Filaments made of polyester are (0.005 in) 0.127 mm in diameter. Transistor lead wires are wrapped around certain filaments. Applicable for testing filament mounts too delicate for testing by tension probes.

Hubbard, W. P.↗