Density dependence of the nuclear symmetry energy from measurements of neutron radii in nuclei

We study the density dependence of the nuclear symmetry energy, characterized by its slope parameter L, by means of the information provided by the neutron radius and the neutron skin thickness in finite nuclei. These quantities are extracted from the analysis of data obtained in antiprotonic atoms, from the parity-violating asymmetry at low-momentum transfer in polarized electron scattering in {sup 208}Pb, and from the electric dipole polarizability obtained via polarized proton inelastic scattering at forward angles in {sup 208}Pb. All these experiments provide different constraints on the slope L of the symmetry energy but the corresponding values have a considerable overlap in a range around 50 MeV ≤ L ≤ 70 MeV, in a reasonable agreement with other estimates that use different observables and methods to extract L.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Chaoticity parameter {lambda} and multiple coherent components in relativistic heavy-ion collisions

Three-pion correlations are conventionally analyzed using a chaotic component and a single coherent component of the emitted pions. The existence of source coherence in these experiments is suggested, but the detailed structure of the coherent component remains obscure. An improved understanding of the coherent processes is obtained by incorporating into the model general properties of pulsed radiation, inspired by the free-electron laser operation with multiple, mutually independent coherent source currents due to electron microbunching. This approach with multiple coherent components solves an inconsistency in the earlier three-pion data analysis and leads to a more appealing description of the experimental results.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Fission Meter Information Barrier Attribute Measurement System: FY2018 Office of Nuclear Verification FNI/UKC Task 2 Documentation Package

The ORTEC Fission Meter is a neutron multiplicity detector developed by Oak Ridge, TN based Advanced Measurement Technology (AMETEK), ORTEC Division. Data analysis techniques developed for neutron multiplicity detectors allows determination of mass and multiplication of unknown objects of special nuclear material (SNM). This can be done based on the physics of fission neutrons with little or no a priori information about the object. The articulating panel design and “5-Mode Counter” neutron multiplicity data-acquisition hardware were licensed to ORTEC by Lawrence Livermore National Laboratory in 2005 based on a 2004 prototype. The “5-Mode Counter” development started in 2000 in order to produce a compact neutron multiplicity file containing the full neutron count timing distribution. Development of this hardware along with the prototype detector design continued through 2004. Photographs of the Fission Meter are shown in Figure 1. In 2011, the Lawrence Livermore National Laboratory developed a software-based information barrier (IB) for the Fission Meter to control transmission of some for potential use in treaty applications. This IB was extended over the next several years to include improvements to the algorithms, more automated processing, and list mode data acquisition and processing. This report provides design and operational documentation for the Fission Meter and the Information Barrier additions.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Status on Development of Graphite Analytical Tool (GAT)

The DOE-ART Graphite R&D program has been generating significant amounts of irradiated and unirradiated graphite data since 2006 when the program was part of the DOE NGNP (Next Generation Nuclear Plant) Project. This data includes critical irradiation creep and irradiated material property changes from the Advanced Graphite Creep (AGR) experiment as well as significant amounts of data on unirradiated material property values on several current nuclear graphite grades (Baseline program). Previously, Idaho National Laboratory has developed an internal analysis tool to assist with analysis of the unirradiated and irradiated data. The Graphite Analytical Tool (GAT) is intended to provide easy access to the graphite data in the form of comparing unirradiated and irradiated material property changes, comparison of material property differences between various nuclear graphite grades, and illustrate trends within the irradiated and unirradiated data generated within the DOE-ART Graphite R&D program. This report summarizes the progress to-date on the development of this analytical tool.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Using Whisper-1.1 to Guide Improvements to Nuclear Data Evaluations

Along with the latest release of the general purpose Monte Carlo radiation transport code, MCNP6.2, came the first officially released version of Whisper, version 1.1, a statistical analysis code used for nuclear criticality safety (NCS) validation. The Whisper software package is primarily used to calculate the upper subcritical limit (USL) of a particular application case along with components of the margin of subcriticality (MOS). In the calculation of the MOS due to nuclear data uncertainties, Whisper uses the generalized linear-least-squares (GLLS) approach to obtain adjusted nuclear data uncertainties which are then propagated to estimate the nuclear data uncertainties in the k eff of the application. Due to the fact that Whisper contains the simulated and measured k eff values for over 1100 benchmarks, nuclear data sensitivity profiles for each benchmark along with the nuclear data covariance matrices, all of which are used in the GLLS method, it is possible to easily utilize these data available to help guide improvements to nuclear data evaluations. In the present work, the Whisper data and the GLLS method are used together to suggest an adjusted nuclear data cross section evaluation specifically for 233 U such that the agreement between the calculated and experimental k eff measurements of the relevant benchmarks are improved. With this adjusted nuclear data available, feedback to the theoretical and experimental nuclear data community is provided.

97 MATHEMATICS AND COMPUTING↗

Using Whisper-1.1 to guide improvements to nuclear data evaluations

Along with the latest release of the general purpose Monte Carlo radiation transport code, MCNP6.2, came the first officially released version of Whisper, version 1.1, a statistical analysis code used for nuclear criticality safety (NCS) validation. The Whisper software package is primarily used to calculate the upper subcritical limit (USL) of a particular application case along with components of the margin of subcriticality (MOS). In the calculation of the MOS due to nuclear data uncertainties, Whisper uses the generalized linear-least-squares (GLLS) approach to obtain adjusted nuclear data uncertainties which are then propagated to estimate the nuclear data uncertainties in the k{sub eff} of the application. Due to the fact that Whisper contains the simulated and measured k{sub eff} values for over 1100 benchmarks, nuclear data sensitivity profiles for each benchmark along with the nuclear data covariance matrices, all of which are used in the GLLS method, it is possible to easily utilize these data available to help guide improvements to nuclear data evaluations. In the present work, the Whisper data and the GLLS method are used together to suggest an adjusted nuclear data cross section evaluation specifically for {sup 233}U such that the agreement between the calculated and experimental k{sub eff} measurements of the relevant benchmarks are improved. With this adjusted nuclear data available, feedback to the theoretical and experimental nuclear data community is provided. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

COBRA-SFS thermal-hydraulic analysis code for spent fuel storage and transportation casks: Models and methods

COBRA-SFS, a thermal-hydraulics code developed for steady-state and transient analysis of multi-assembly spent-fuel storage and transportation systems, has been incorporated into the Used Nuclear Fuel-Storage, Transportation and Disposal Analysis Resource and Data System tool as a module devoted to spent fuel package thermal analysis. This paper summarizes the basic formulation of the equations and models used in the COBRA-SFS code, showing that COBRA-SFS fully captures the important physical behavior governing the thermal performance of spent fuel storage systems, with internal and external natural convection flow patterns, and heat transfer by convection, conduction, and thermal radiation. Of particular significance is the capability for detailed thermal radiation modeling within the fuel rod array.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Spectroscopic Online Monitoring for Process Control and Safeguarding of Radiochemical Fuel Reprocessing Streams - 13553

There is a renewed interest worldwide to promote the use of nuclear power and close the nuclear fuel cycle. The long term successful use of nuclear power is critically dependent upon adequate and safe processing and disposition of the used nuclear fuel. Liquid-liquid extraction is a separation technique commonly employed for the processing of the dissolved spent nuclear fuel. The instrumentation used to monitor these processes must be robust, require little or no maintenance, and be able to withstand harsh environments such as high radiation fields and aggressive chemical matrices. This paper discusses application of absorption and vibrational spectroscopic techniques supplemented by physicochemical measurements for radiochemical process monitoring. In this context, our team experimentally assessed the potential of Raman and spectrophotometric techniques for on-line real-time monitoring of the U(VI)/nitrate ion/nitric acid and Pu(IV)/Np(V)/Nd(III), respectively, in solutions relevant to spent fuel reprocessing. Both techniques demonstrated robust performance in the repetitive batch measurements of each analyte in a wide concentration range using simulant and commercial dissolved spent fuel solutions. Static spectroscopic measurements served as training sets for the multivariate data analysis to obtain partial least squares predictive models, which were validated using on-line centrifugal contactor extraction tests. Satisfactory prediction of the analytes concentrations in these preliminary experiments warrants further development of the spectroscopy-based methods for radiochemical safeguards and process control. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

SDAT – Analysis of 131mXe with 133Xe Interference

The Spectral Deconvolution Analysis Tool (SDAT) software was developed at The University of Texas at Austin. SDAT utilizes a standard spectrum technique for the analysis of beta-gamma coincidence spectra. Testing was performed on the software to compare the standard spectrum analysis technique with a region of interest (ROI) analysis technique. Experimentally produced standard spectra and sample data were produced at the Nuclear Engineering Teaching Laboratory (NETL) TRIGA reactor. The results of the testing showed that the standard spectrum technique had lower errors than the ROI analysis technique for samples with low counting statistics. In contrast, the ROI analysis technique outperformed the standard spectrum technique in high counting statistics samples. It was also shown that the standard spectrum technique benefitted from a compression of the number of channels within the spectra.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

HDG-1 Fiber Bragg grating data analysis

The main goal of the High dose graphite 1 Advanced test reactor experiment was to study nuclear grade graphite at high fluences. Additional supplementary optical fiber instrumentation was added to this long duration experiment for instrumentation development purposes. The supplementary instrumentation consisted of two pure silica core, fluorine doped cladding optical fibers each etched with 9 fiber Bragg gratings, one fiber being heat treated for 9 hours at 750 C and 16 hours at 750 C, the other being heat treated for 24 hours at 550 C and 48 hours at 650 C. Fiber Bragg gratings are known to have issues of measurement drift when in high temperature and high radiation environments like what is encountered in the Advanced test reactor. At the culmination of this experiment, the optical fibers saw ~1.3E21 n/cm2 total fluence, which is at the highest fluences that fiber Bragg gratings have been studied to date. Reported here is the analysis of this data including radiation induced shift and changes in sensitivity.

46 - INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AN↗

Using Cross-Section Uncertainty Data to Estimate Biases

Ideally, computational method validation is performed by modeling critical experiments that are very similar, neutronically, to the model used in the safety analysis. Similar, in this context, means that the neutron multiplication factors (k eff ) of the safety analysis model and critical experiment model are affected in the same way to the same degree by variations (or errors) in the same nuclear data. Where similarity is demonstrated, the computational bias calculated using the critical experiment model results is 'applicable' to the safety analysis model. Unfortunately, criticality safety analysts occasionally find that the safety analysis models include some feature or material for which adequately similar well-defined critical experiments do not exist to support validation. For example, the analyst may want to take credit for the presence of fission products in spent nuclear fuel. In such cases, analysts sometimes rely on 'expert judgment' to assign an additional administrative margin to compensate for the validation weakness or to conclude that the impact on the calculated bias and bias uncertainty is negligible. Due to advances in computer programs and the evolution of cross-section uncertainty data, analysts can use the sensitivity and uncertainty analyses tools implemented in the SCALE TSUNAMI codes to estimate the potential impact on the application-specific bias and bias uncertainty resulting from nuclides that are under-represented or not present in the critical experiments. This paper discusses the method, computer codes, and data used to estimate the potential contribution toward the computational bias of individual nuclides. The results from application of the method to fission products in a burnup credit model are presented.

97 MATHEMATICS AND COMPUTING↗

FY 22 Project Name: Boots versus Bytes

IAEA has increasingly leveraged remote data transfer, amplifying the effectiveness of inspectors and analysts by allowing them to view data from Headquarters rather than requiring on-site activities. We propose that there may be even more opportunities to shift the international nuclear safeguards paradigm to remote activities through the implementation of enhanced data sharing and analysis.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Reactivity worth measurements at the IPEN/MB-01 nuclear reactor

Researches that aim to improve the performance of neutron transport codes and quality of nuclear cross section databases are very important to increase the accuracy of simulations and the quality of the analysis and prediction of phenomena in the nuclear field. In this context, relevant experimental data such as reactivity worth measurements are needed. The objective of this work was to perform a series of experiments of reactivity worth measurements, using a digital reactivity meter developed at IPEN. The experiments employed small metallic and ceramic samples inserted in the central region of the core of the experimental IPEN/MB-01 reactor. The theoretical analysis was performed by the MCNP-5 reactor physics code, developed and maintained by Los Alamos National Laboratory, and the ENDF/B-VII.0 nuclear data library.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

New search for double electron capture in {sup 106}Cd decay with the TGV-2 spectrometer

A new experiment devoted to searches for double electron capture in {sup 106}Cd decay is being performed at the Modane underground laboratory (4800 mwe) with the 32-detector TGV-2 spectrometer. The limit T{sub 1/2}(2νEC/EC) > 2.0×10{sup 20} yr at a 90%confidence level (C.L.) was obtained from a preliminary analysis of data obtained over 2250 h of measurements with about 23.2 g sample enriched in the isotope {sup 106}Cd to 99.57%. The limits T{sub 1/2}(KL, 2741 keV) > 0.9 × 10{sup 20} yr and T{sub 1/2}(KK, 2718 keV) ≫ 1.4 × 10{sup 20} yr at a 90% C.L. on the neutrinoless decay of {sup 106}Cd were obtained from measurements performed with the Obelix low-background spectrometer from high-purity germanium (HPGe spectrometer) for a sample of mass about 23.2 g enriched in the isotope {sup 106}Cd.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

The IAEA Coordinated Research Program on HTGR Reactor Physics, Thermal-hydraulics and Depletion Uncertainty Analysis: Description of the Benchmark Test Cases and Phases

The continued development of High Temperature Gas Cooled Reactors (HTGRs) requires verification of design and safety features with reliable high fidelity physics models and robust, efficient, and accurate codes. The uncertainties in the HTR analysis tools are today typically assessed with sensitivity analysis and then a few important input uncertainties (typically based on a PIRT process) are varied in the analysis to find a spread in the parameter of importance. However, one wish to apply a more fundamental approach to determine the predictive capability and accuracies of coupled neutronics/thermal-hydraulics and depletion simulations used for reactor design and safety assessment. Today there is a broader acceptance of the use of uncertainty analysis even in safety studies and it has been accepted by regulators in some cases to replace the traditional conservative analysis. Finally, there is also a renewed focus in supplying reliable covariance data (nuclear data uncertainties) that can then be used in uncertainty methods. Uncertainty and sensitivity studies are therefore becoming an essential component of any significant effort in data and simulation improvement. In order to address uncertainty in analysis and methods in the HTGR community the IAEA launched a Coordinated Research Project (CRP) on the HTGR Uncertainty Analysis in Modelling early in 2012. The project is built on the experience of the OECD/NEA Light Water Reactor (LWR) Uncertainty Analysis in Best-Estimate Modelling (UAM) benchmark activity, but focuses specifically on the peculiarities of HTGR designs and its simulation requirements. Two benchmark problems were defined with the prismatic type design represented by the MHTGR-350 design from General Atomics (GA) while a 250 MW modular pebble bed design, similar to the INET (China) and indirect-cycle PBMR (South Africa) designs are also included. In the paper more detail on the benchmark cases, the different specific phases and tasks and the latest status and plans are presented.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Experimental study of the A(e,e'{pi}{sup +}) reaction on {sup 1}H, {sup 2}H, {sup 12}C, {sup 27}Al, {sup 63}Cu and {sup 197}Au.

Cross sections for the {sup 1}H(e,e'{pi}{sup +})n process on {sup 1}H, {sup 2}H, {sup 12}C, {sup 27}Al, {sup 63}Cu, and {sup 197}Au targets were measured at the Thomas Jefferson National Accelerator Facility (Jefferson Lab) to extract nuclear transparencies. Data were taken from Q{sup 2}=1.1-4.7 GeV{sup 2} for a fixed center-of-mass energy of W=2.14 GeV. The ratio of {sigma}{sub L} and {sigma}{sub T} was extracted from the measured cross sections for {sup 1}H, {sup 2}H, {sup 12}C, and {sup 63}Cu targets at Q{sup 2}=2.15 and 4.0 GeV{sup 2}, allowing for additional studies of the reaction mechanism. In this article, we present the experimental setup and the analysis of the data in detail, including systematic uncertainty studies. Differential cross sections and nuclear transparencies as a function of the pion momentum at different values of Q{sup 2} are presented. Our results are consistent with the predicted early onset of color transparency in mesons. Global features of the data are discussed and the data are compared with model calculations for the {sup 1}H(e,e'{pi}{sup +})n reaction from nuclear targets.

43 PARTICLE ACCELERATORS↗

Using artificial intelligence to detect human errors in nuclear power plants: A case in operation and maintenance

Human error (HE) is an important concern in safety-critical systems such as nuclear power plants (NPPs). HE has played a role in many accidents and outage incidents in NPPs. Despite the increased automation in NPPs, HE remains unavoidable. Hence, the need for HE detection is as important as HE prevention efforts. In NPPs, HE is rather rare. Hence, anomaly detection, a widely used machine learning technique for detecting rare anomalous instances, can be repurposed to detect potential HE. In this study, we develop an unsupervised anomaly detection technique based on generative adversarial networks (GANs) to detect anomalies in manually collected surveillance data in NPPs. More specifically, our GAN is trained to detect mismatches between automatically recorded sensor data and manually collected surveillance data, and hence, identify anomalous instances that can be attributed to HE. We test our GAN on both a real-world dataset and an external dataset obtained from a testbed, and we benchmark our results against state-of-the-art unsupervised anomaly detection algorithms, including one-class support vector machine and isolation forest. Our results show that the proposed GAN provides improved anomaly detection performance. Our study is promising for the future development of artificial intelligence based HE detection systems.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Surface characterization of nanomaterials and nanoparticles: Important needs and challenging opportunities

This review examines characterization challenges inherently associated with understanding nanomaterials and the roles surface and interface characterization methods can play in meeting some of the challenges. In parts of the research community, there is growing recognition that studies and published reports on the properties and behaviors of nanomaterials often have reported inadequate or incomplete characterization. As a consequence, the true value of the data in these reports is, at best, uncertain. With the increasing importance of nanomaterials in fundamental research and technological applications, it is desirable that researchers from the wide variety of disciplines involved recognize the nature of these often unexpected challenges associated with reproducible synthesis and characterization of nanomaterials, including the difficulties of maintaining desired materials properties during handling and processing due to their dynamic nature. It is equally valuable for researchers to understand how characterization approaches (surface and otherwise) can help to minimize synthesis surprises and to determine how (and how quickly) materials and properties change in different environments. Appropriate application of traditional surface sensitive analysis methods (including x-ray photoelectron and Auger electron spectroscopies, scanning probe microscopy, and secondary ion mass spectroscopy) can provide information that helps address several of the analysis needs. In many circumstances, extensions of traditional data analysis can provide considerably more information than normally obtained from the data collected. Less common or evolving methods with surface selectivity (e.g., some variations of nuclear magnetic resonance, sum frequency generation, and low and medium energy ion scattering) can provide information about surfaces or interfaces in working environments (operando or in situ) or information not provided by more traditional methods. Although these methods may require instrumentation or expertise not generally available, they can be particularly useful in addressing specific questions, and examples of their use in nanomaterial research are presented.

77 NANOSCIENCE AND NANOTECHNOLOGY↗