Search NASA⌕ Search

SEARCH · Search NASA

Results for “ORIFICES”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 721 records · Page 40

Flow distribution analysis on the cooling tube network of ITER thermal shield

Thermal shield (TS) is to be installed between the vacuum vessel or the cryostat and the magnets in ITER tokamak to reduce the thermal radiation load to the magnets operating at 4.2K. The TS is cooled by pressurized helium gas at the inlet temperature of 80K. The cooling tube is welded on the TS panel surface and the composed flow network of the TS cooling tubes is complex. The flow rate in each panel should be matched to the thermal design value for effective radiation shielding. This paper presents one dimensional analysis on the flow distribution of cooling tube network for the ITER TS. The hydraulic cooling tube network is modeled by an electrical analogy. Only the cooling tube on the TS surface and its connecting pipe from the manifold are considered in the analysis model. Considering the frictional factor and the local loss in the cooling tube, the hydraulic resistance is expressed as a linear function with respect to mass flow rate. Sub-circuits in the TS are analyzed separately because each circuit is controlled by its own control valve independently. It is found that flow rates in some panels are insufficient compared with the design values. In order to improve the flow distribution, two kinds of design modifications are proposed. The first one is to connect the tubes of the adjacent panels. This will increase the resistance of the tube on the panel where the flow rate is excessive. The other design suggestion is that an orifice is installed at the exit of tube routing where the flow rate is to be reduced. The analysis for the design suggestions shows that the flow mal-distribution is improved significantly.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Oxygen transport in the internal xenon plasma of a dispenser hollow cathode

Reactive gases such as oxygen and water vapor modify the surface morphology of BaO dispenser cathodes and degrade the electron emission properties. For vacuum cathodes operating at fixed temperature, the emission current drops rapidly when oxygen adsorbs on top of the low work function surface. Previous experiments have shown that plasma cathodes are more resistant to oxygen poisoning and can operate with O{sub 2} partial pressures one to two orders of magnitude higher than vacuum cathodes before the onset of poisoning occurs. Plasma cathodes used for electric thrusters are typically operated with xenon; however, gas phase barium, oxygen, and tungsten species may be found in small concentrations. The densities of these minor species are small compared with the plasma density, and thus, their presence in the discharge does not significantly alter the xenon plasma parameters. It is important, however, to consider the transport of these minor species as they may deposit on the emitter surface and affect the electron emission properties. In this work, we present the results of a material transport model used to predict oxygen fluxes to the cathode surface by solving the species conservation equations in a cathode with a 2.25 mm diameter orifice operated at a discharge current of 15 A, a Xe flow rate of 3.7 sccm, and 100 ppm of O{sub 2}. The dominant ionization process for O{sub 2} is resonant charge exchange with xenon ions. Ba is effectively recycled in the plasma; however, BaO and O{sub 2} are not. The model shows that the oxygen flux to the surface is not diffusion-limited; therefore, the high resistance to oxygen poisoning observed in plasma cathodes likely results from surface processes not considered here.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

The plasma properties and electron emission characteristics of near-zero differential resistance of hollow cathode-based plasma contactors with a discharge chamber

The formation of electron emission-bias voltage (I-V) characteristics of near-zero differential resistance in the cathodic plasma contactor for bare electrodynamic tether applications, based on a hollow cathode embedded in a ring-cusp ionization stage, is studied. The existence of such an I-V regime is important to achieve low impedance performance without being affected by the space plasma properties for a cathodic plasma contactor. Experimental data on the plasma structure and properties downstream from the ionization stage are presented as functions of the xenon flow rate and the electron emission current. The electrons were emitted from the cathode to the cylindrical vacuum chamber wall (r = 0.9 m) under ≈10{sup −5 }Torr of vacuum pressure. The ring-cusp configuration selected for the plasma contactor created a 125-Gauss axial field near the cathode orifice, along with a large-volume 50-Gauss magnitude pocket in the stage. A baseline ion energy cost of ≈300 eV/ion was measured in the ionization stage when no electrons were emitted to the vacuum chamber wall. In addition, the anode fall growth limited the maximum propellant unitization to below ≈75% in the discharge loss curves for this ion stage. Detailed measurements on the plasma properties were carried out for the no-electron emission and 3 A emission conditions. The experimental data are compared with 1-D models, and the effectiveness of the model is discussed. The four key issues that played important roles in the process of building the near-zero different resistance I-V regime are: a significant amount of ionization by the emission electrons, a decrease in the number of reflected electrons in the plume, the electron-temperature increment, and low initial ion energy at the source outlet.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Experimental investigation on structures and velocity of liquid jets in a supersonic crossflow

Particle image velocimetry was applied in the study focusing on the structure and velocity of water jets injected into a Ma = 2.1 crossflow. The instantaneous structures of the jet, including surface waves in the near-injector region and vortices in the far-field, were visualized clearly. Spray velocity increases rapidly to 66% of the mainstream velocity in the region of x/d < 15, owing to the strong gas-liquid interaction near the orifice. By contrast, the velocity grows slowly in the far-field region, where the liquid inside the spray is accelerated mainly by the continuous driven force provided by the mainstream with the gas-liquid shear. The injection and atomization of liquid jet in a supersonic crossflow serves as a foundation of scramjet combustion process, by affecting the combustion efficiency and some other performances. With various forces acting on the liquid jet (Mashayek et al. [AIAA J. 46, 2674–2686 (2008)] and Wang et al. [AIAA J. 50, 1360–1366 (2012)]), the atomization process involves very complex flow physics. These physical processes include strong vortical structures, small-scale wave formation, stripping of small droplets from the jet surface, formations of ligaments, and droplets with a wide range of sizes.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

High field electron paramagnetic resonance spectroscopy under ultrahigh vacuum conditions—A multipurpose machine to study paramagnetic species on well defined single crystal surfaces

A new ultrahigh vacuum (UHV) electron paramagnetic resonance (EPR) spectrometer operating at 94 GHz to investigate paramagnetic centers on single crystal surfaces is described. It is particularly designed to study paramagnetic centers on well-defined model catalysts using epitaxial thin oxide films grown on metal single crystals. The EPR setup is based on a commercial Bruker E600 spectrometer, which is adapted to ultrahigh vacuum conditions using a home made Fabry Perot resonator. The key idea of the resonator is to use the planar metal single crystal required to grow the single crystalline oxide films as one of the mirrors of the resonator. EPR spectroscopy is solely sensitive to paramagnetic species, which are typically minority species in such a system. Hence, additional experimental characterization tools are required to allow for a comprehensive investigation of the surface. The apparatus includes a preparation chamber hosting equipment, which is required to prepare supported model catalysts. In addition, surface characterization tools such as low energy electron diffraction (LEED)/Auger spectroscopy, temperature programmed desorption (TPD), and infrared reflection absorption spectroscopy (IRAS) are available to characterize the surfaces. A second chamber used to perform EPR spectroscopy at 94 GHz has a room temperature scanning tunneling microscope attached to it, which allows for real space structural characterization. The heart of the UHV adaptation of the EPR experiment is the sealing of the Fabry-Perot resonator against atmosphere. To this end it is possible to use a thin sapphire window glued to the backside of the coupling orifice of the Fabry Perot resonator. With the help of a variety of stabilization measures reducing vibrations as well as thermal drift it is possible to accumulate data for a time span, which is for low temperature measurements only limited by the amount of liquid helium. Test measurements show that the system can detect paramagnetic species with a density of approximately 5 × 10{sup 11} spins/cm{sup 2}, which is comparable to the limit obtained for the presently available UHV-EPR spectrometer operating at 10 GHz (X-band). Investigation of electron trapped centers in MgO(001) films shows that the increased resolution offered by the experiments at W-band allows to identify new paramagnetic species, that cannot be differentiated with the currently available methodology.

36 MATERIALS SCIENCE↗

Vibrational modes of ultrathin carbon nanomembrane mechanical resonators

We report measurements of vibrational mode shapes of mechanical resonators made from ultrathin carbon nanomembranes (CNMs) with a thickness of approximately 1 nm. CNMs are prepared from electron irradiation induced cross-linking of aromatic self-assembled monolayers and the variation of membrane thickness and/or density can be achieved by varying the precursor molecule. Single- and triple-layer freestanding CNMs were made by transferring them onto Si substrates with square/rectangular orifices. The vibration of the membrane was actuated by applying a sinusoidal voltage to a piezoelectric disk on which the sample was glued. The vibrational mode shapes were visualized with an imaging Mirau interferometer using a stroboscopic light source. Several mode shapes of a square membrane can be readily identified and their dynamic behavior can be well described by linear response theory of a membrane with negligible bending rigidity. By applying Fourier transformations to the time-dependent surface profiles, the dispersion relation of the transverse membrane waves can be obtained and its linear behavior verifies the membrane model. By comparing the dispersion relation to an analytical model, the static stress of the membranes was determined and found to be caused by the fabrication process.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Experimental study of elliptical jet from supercritical to subcritical conditions using planar laser induced fluorescence

The study of fluid jet dynamics at supercritical conditions involves strong coupling between fluid dynamic and thermodynamic phenomena. Beyond the critical point, the liquid-vapor coexistence ceases to exist, and the fluid exists as a single phase known as supercritical fluid with its properties that are entirely different from liquids and gases. At the critical point, the liquids do not possess surface tension and latent heat of evaporation. Around the critical point, the fluid undergoes large changes in density and possesses thermodynamic anomaly like enhancement in thermal conductivity and specific heat. In the present work, the transition of the supercritical and near-critical elliptical jet into subcritical as well as supercritical environment is investigated experimentally with nitrogen and helium as the surrounding environment. Under atmospheric condition, a liquid jet injected from the elliptical orifice exhibits axis switching phenomena. As the injection temperature increases, the axis switching length also increases. Beyond the critical temperature, the axis switching is not observed. The investigation also revealed that pressure plays a major role in determining the thermodynamic transition of the elliptical jet only for the case of supercritical jet injected into subcritical chamber conditions. At larger pressures, the supercritical jet undergoes disintegration and formation of droplets in the subcritical environment is observed. However, for supercritical jet injection into supercritical environment, the gas-gas like mixing behavior is observed.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Note: Real-time monitoring via second-harmonic interferometry of a flow gas cell for laser wakefield acceleration

The use of a gas cell as a target for laser wakefield acceleration (LWFA) offers the possibility to obtain stable and manageable laser-plasma interaction process, a mandatory condition for practical applications of this emerging technique, especially in multi-stage accelerators. In order to obtain full control of the gas particle number density in the interaction region, thus allowing for a long term stable and manageable LWFA, real-time monitoring is necessary. In fact, the ideal gas law cannot be used to estimate the particle density inside the flow cell based on the preset backing pressure and the room temperature because the gas flow depends on several factors like tubing, regulators, and valves in the gas supply system, as well as vacuum chamber volume and vacuum pump speed/throughput. Here, second-harmonic interferometry is applied to measure the particle number density inside a flow gas cell designed for LWFA. The results demonstrate that real-time monitoring is achieved and that using low backing pressure gas (<1 bar) and different cell orifice diameters (<2 mm) it is possible to finely tune the number density up to the 10{sup 19} cm{sup −3} range well suited for LWFA.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Characterization of a 100 micrometer-scale cryogenically cooled gas jet for near-critical density laser-plasma experiments

In this work, we present the design and characterization of a thin, high density pulsed gas jet for use in the study of near critical laser plasma interactions with ultrashort Ti:sapphire laser pulses. The gas jet uses a range of capillary nozzles with inner diameters between 50 and 150 μm and is operated in the sonic regime. Cryogenic cooling of the gas valve body to -160°C provides the necessary density enhancement for reaching overcritical plasma densities at λ = 800 nm (N cr ≈ 1.7 × 1021 cm -3 ) using hydrogen gas at jet backing pressures below 1000 psi. Under certain conditions, fast expansion of the gas from a nozzle can lead to formation of clusters; here, we use our previously demonstrated all-optical method to estimate the cluster mean size and density. For the jets studied here, we find that cluster formation only begins at distances from the nozzle exit greater than a few times the nozzle orifice diameter.

47 OTHER INSTRUMENTATION↗

Dynamic thermal behavior of polycrystalline LaB 6 hollow cathodes

Lanthanum hexaboride (LaB6) hollow cathodes have demonstrated a capability for long life operation, which is critical to many space exploration missions. Thermal characterization of LaB6 hollow cathodes has revealed lower than expected electron emitter temperatures when the cathode reaches a steady state. This phenomenon is observed at discharge currents ranging from 5 to 35 A and xenon mass flow rates of 5–25 SCCM in cathodes with three different orifice diameters. Thus, the currently accepted value of the work function for polycrystalline LaB 6 , 2.67 eV, does not describe well the emission characteristics of LaB6 hollow cathodes operating with internal gas discharges at a steady state. We use empirically measured temperatures combined with a model of the hollow cathode emitter and xenon discharge to estimate the value of the work function, yielding a value ranging from 2.1 to 2.44 eV. This lower work function value implies that LaB6 hollow cathodes are expected to have even longer lifetimes than previously anticipated, further establishing them as a more suited alternative to other conventional cathode technologies for the task of long duration travel. Direct measurements of the work function as a function of depth on a hollow cathode emitter using x-ray photoelectron spectroscopy and ion beam milling indicate that the work function decreases with depth. We postulate several mechanisms that could explain the observed work function enhancement. Altogether, our results have important implications to the design, study approach, and operation of LaB 6 cathodes and potentially other cathodes with hollow configuration. Finally, our work opens the question of why the work function is reduced upon interaction with Xe plasma.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Flagellum couples cell shape to motility in Trypanosoma brucei

In the unicellular parasite Trypanosoma brucei, the causative agent of human African sleeping sickness, complex swimming behavior is driven by a flagellum laterally attached to the long and slender cell body. Using microfluidic assays, we demonstrated that T. brucei can penetrate through an orifice smaller than its maximum diameter. Efficient motility and penetration depend on active flagellar beating. To understand how active beating of the flagellum affects the cell body, we genetically engineered T. brucei to produce anucleate cytoplasts (zoids and minis) with different flagellar attachment configurations and different swimming behaviors. We used cryo-electron tomography (cryo-ET) to visualize zoids and minis vitrified in different motility states. Here, we showed that flagellar wave patterns reflective of their motility states are coupled to cytoskeleton deformation. Based on these observations, we propose a mechanism for how flagellum beating can deform the cell body via a flexible connection between the flagellar axoneme and the cell body. Lastly, this mechanism may be critical for T. brucei to disseminate in its host through size-limiting barriers.

59 BASIC BIOLOGICAL SCIENCES↗

Computational Thermal Hydraulics of a High-Performance Low-Enriched-Uranium Annular Target for HFIR Irradiation

Molybdenum-99 has historically been generated via isolation from fissioned highly enriched uranium (HEU) targets. Here, this isotope is in high demand due to its daily use across the world in radiopharmaceutical medical procedures. The primary objective of this work was to design and analyze an experimental target assembly containing one low-enriched-uranium (LEU) annular target for irradiation at the High Flux Isotope Reactor (HFIR). Efforts included incorporating spatially dependent energy sources from neutron and gamma interactions, quantifying thermal contact conductance at material interfaces, performing grid-independent studies, comparing turbulence models, and simulating various steady-state and transient scenarios relevant for irradiation qualification and eventual insertion. These models provide velocity, pressure, and temperature distributions in both space and time. Such results enable the selection of an appropriate irradiation location, fission rate density, and flow-limiting orifice size and demonstrate compliance with HFIR safety requirements such that insertion into the reactor can be approved. This analysis shows that across all scenarios, wetted surface temperatures remain below the coolant saturation temperature with no net vapor formation in the coolant. In every scenario, all components stay below 30% of the aluminum 6061 melting temperature. Computational fluid dynamics and system-level models predict peak target temperatures that agree within 4%, though the predicted axial location of the peak differs by about 10% of the heated length due to differences in flow development length. These results de-risk the irradiation of LEU (annular targets) and strengthen a domestic, HEU-independent 99 Mo supply by providing important fuel performance data to form the foundation for a robust licensing basis.

Molybdenum-99↗

Comparison of experimental and numerical studies of the performance characteristics of a pumped counterflow virtual impactor

Experiments and Computational Fluid Dynamic (CFD) simulations were performed to evaluate the performance characteristics of a Pumped Counterflow Virtual Impactor (PCVI). Tests were conducted for various flow configurations for which the diameter at which 50% of the particles were transmitted was determined. Experimentally determined 50% cutpoints varied from 2.2 to 4.8 micrometers and CFD predicted diameters agreed within ± 0.4 microns. Both experimental and CFD results showed similar transmission efficiency (TE) curves. CFD TE was always greater than experimental results, most likely due to impaction losses in fittings not included in the simulations. Ideal transmission, corresponding to 100% TE, was never realized in either case due to impaction losses and small scale flow features such as eddies. Areas where CFD simulations showed such flow recirculation zones were also found to be the locations where particulate residue was deposited during experiments. CFD parametric tests showed that PCVI performance can be affected by the nozzle geometry and misalignment between the nozzle and collector orifice. We conclude that CFD can be used with confidence for counterflow virtual impactor (CVI) design. Modifications to improve the performance characteristics of the PCVI are suggested.

42 ENGINEERING↗

Performance of pumped counterflow virtual impactors to study aerosol interactions with laboratory generated warm clouds

Pumped Counterflow Virtual Impactors (PCVI) are designed to separate aerosols based on aerodynamic diameter, which is particularly useful for isolating cloud droplets and ice crystals from smaller particles. However, the PCVI transmission efficiency (TE) values reported in the literature show considerable variability, and little information is available on the TEs for cloud liquid droplets. Here, we determined the optimal flow conditions for PCVI sampling for different activation ratios from the MTU Pi-cloud chamber, highlighting the conditions that maximize droplet residual sampling while minimizing interstitial transmission. Even for a lower limit cloud activation ratio = 1:10, an add flow of 1.5 LPM achieves a residual fraction greater than 0.80, with a droplet TE of ∼15% for typical Pi-Chamber droplets with diameters between 3.5 to 10 µm. This framework can be adapted for field cloud measurements based on the cloud conditions of interest. TE for cloud droplets under flow conditions at which ∼99% of the unactivated submicron particles were removed was substantially lower between 8 and 16% than for supermicron dry particles (∼30 to 40% for 3 µm polystyrene latex spheres). In addition, we conducted a comparison of the performances of three similar PCVI units to assess repeatability for dry aerosols and cloud droplets. All three PCVIs performed similarly in rejecting submicron particles smaller than the desired cutoff diameter. One of the units showed lower TEs due to a misalignment of the internal orifice. We discuss a procedure that improved alignment and performance.

54 ENVIRONMENTAL SCIENCES↗

Monte Carlo Analysis of the Performance of the ITER Diagnostic Residual Gas Analyzer

The composition of exhausted gas is a key parameter in long-pulse plasma fusion experiments, and its evolution shall be monitored at timescales relevant to plasma dynamics and plasma-wall interactions. A diagnostic residual gas analyzer (DRGA) is a multisensor instrument particularly suited to these studies, and ITER will adopt DRGAs in the equatorial and in the divertor tokamak regions. In this work, we have revisited the design of the ITER divertor DRGA through simple vacuum analytical considerations supported by simulations conducted with Molflow+, a test particle Monte Carlo (TPMC) simulation code commonly used in the particle accelerator community. Here, starting with recommendations on the manufacturing of the vacuum piping of the DRGA, this work is followed by a complete vacuum characterization of the diagnostic vacuum setup (pressure profiles at base pressure and during sampling, orifice diameter, and length optimization), and finally, the in-vessel residence time of the most important gas species is simulated. These studies have allowed us to give insights into some experimental results recently found on the prototype DRGA installed in the Wendelstein W7-X stellarator.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Characterization of the Emissions and Crystalline Silica Content of Airborne Dust Generated from Grinding Natural and Engineered Stones

Abstract In this study, we systematically characterized the airborne dust generated from grinding engineered and natural stone products using a laboratory testing system designed and operated to collect representative respirable dust samples. Four stone samples tested included two engineered stones consisting of crystalline silica in a polyester resin matrix (formulations differed with Stones A having up to 90wt% crystalline silica and Stone B up to 50wt% crystalline silica), an engineered stone consisting of recycled glass in a cement matrix (Stone C), and a granite. Aerosol samples were collected by respirable dust samplers, total dust samplers, and a Micro-Orifice Uniform Deposit Impactor. Aerosol samples were analyzed by gravimetric analysis and x-ray diffraction to determine dust generation rates, crystalline silica generation rates, and crystalline silica content. Additionally, bulk dust settled on the floor of the testing system was analyzed for crystalline silica content. Real-time particle size distributions were measured using an Aerodynamic Particle Sizer. All stone types generated similar trimodal lognormal number-weighted particle size distributions during grinding with the most prominent mode at an aerodynamic diameter of about 2.0-2.3 μm, suggesting dust formation from grinding different stones is similar. Bulk dust from Stone C contained no crystalline silica. Bulk dust from Stone A, Stone B, and granite contained 60, 23, and 30wt% crystalline silica, respectively. In Stones A and B, the cristobalite form of crystalline silica was more plentiful than the quartz form. Only the quartz form was detected in granite. The bulk dust, respirable dust, and total dust for each stone had comparable amounts of crystalline silica, suggesting that crystalline silica content in the bulk dust could be representative of that in respirable dust generated during grinding. Granite generated more dust per unit volume of material removed than the engineered stones, which all had similar normalized dust generation rates. Stone A had the highest normalized generation rates of crystalline silica, followed by granite, Stone B, and Stone C (no crystalline silica), which likely leads to the same trend of respirable crystalline silica (RCS) exposure when working with these different stones. Manufacturing and adoption of engineered stone products with formulations such as Stone B or Stone C could potentially lower or eliminate RCS exposure risks. Combining all the effects of dust generation rate, size-dependent silica content, and respirable fraction, the highest normalized generation rate of RCS consistently occurs at 3.2-5.6 µm for all the stones containing crystalline silica. Therefore, removing particles in this size range near the generation sources should be prioritized when developing engineering control measures.

Public, Environmental & Occupational Health↗

Improvements on the Diagnostic Residual Gas Analyzer at Wendelstein 7-X

Exhaust gas analysis provides key information on fusion processes, divertor operation, and wall state in fusion experiments and future reactors. The diagnostic residual gas analyzer (DRGA) concept has been developed for ITER with a focus on fast helium and hydrogen isotope detection. The first operation of the prototype DRGA (P-DRGA) at the stellarator Wendelstein 7-X showed potential for improvement in terms of magnetic sensor shielding, data acquisition automation, and potential new additions to the cluster of sensors on the P-DRGA. More recently, a Monte Carlo simulation of the flow of the mixed gas species effluent from the pressure-reducing orifice, down to about 8-m sampling tube and into the analysis region of the sensors, has been found to generally agree with previous calculations and measurements but revealed potential back-streaming effects for light gases, with impact on detection limits both for the prototype and for the ITER DRGA currently in design. For the upcoming campaign of the prototype, an enhanced soft iron shield will safeguard the gauges against magnetic stray field influence. The newly introduced shielding has been tested for its effect on magnetic stray fields and found to reduce the inside residual field by about two orders of magnitude.

Schlisio, G↗

Seasonal to Decadal Variability in Focused Groundwater and Contaminant Discharge along a Channelized Stream

Abstract Focused groundwater discharge to streams is problematic at contaminated sites because high fluxes can limit natural attenuation in the hyporheic zone. However, information on location, spatial evolution, and temporal persistence of springs in unlithified sediments over multiyear time scales is limited. We examine discharge at point (~1‐m) to reach (~300‐m) scales along a stream that intercepts trichloroethene and technetium‐99 plumes from a Superfund site. During 2011 to 2012, we seasonally monitored stream and spring flow and contaminant concentrations, along with probing streambed temperatures on a grid in winter and summer, building on prior monitoring during 1999 to 2002. Baseflow measured by both gauging and dye dilution generally increased with distance downstream, and stream and spring discharge varied seasonally, from minima in October to January to maxima in February to June. Thermal anomalies identified by probing occupied approximately 3% to 6% of the reach and typically coincided with visible springs or seeps. Locations of anomalies were similar to those identified in summer 2002, although some orifices disappeared and others emerged. Vertical groundwater fluxes calculated from probing tended to be less than net fluxes calculated from stream discharge, perhaps in part because the assumption of one‐dimensional, steady‐state flow in calculating point fluxes was simplistic. Maximum contaminant concentrations and fluxes decreased between 1999 to 2001 and 2011 to 2012 as a result of partial capture by an upgradient pump‐and‐treat system. Our findings confirm that springs in unlithified sediments can remain stationary within a few meters over decadal time scales, and seasonal variability in discharge can be greater than decadal variability.

Tripathi, Ganesh N.↗