Search NASA⌕ Search

SEARCH · Search NASA

Results for “Performance Deviation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 721 records · Page 40

Lumen Maintenance and Light Loss Factors: Consequences of Current Design Practices for LED's

Synopsis: Light loss factors are used to help lighting systems meet quantitative design criteria throughout the life of the installation, but they also influence energy use. As the light sources currently being specified continue to evolve, it is necessary to reevaluate the methods used in calculating light loss factors, as well as carefully consider the consequences of different product performance attributes. Because of the unique operating characteristics of LEDs and lack of a comprehensive lifetime rating—as well as the problematic relationship between lifetime and lumen maintenance—determining an appropriate lamp lumen depreciation (LLD) factor for LED products is difficult. As a result, a unique solution has been advocated: when quantity of light is an important design consideration, the IES recommends using an LLD of not greater than 0.70. This method deviates from the typical practice for conventional sources of using the ratio of mean to initial lumen output, and can misrepresent actual performance, increase energy use, and inhibit comparisons between products. This paper discusses the complications related to LLD and LEDs, compares the performance of conventional and LED products, and examines alternatives to a maximum LLD of 0.70 for LEDs.

Energy Efficiency↗

Deep-Learning-Based Koopman Modeling for Online Control Synthesis of Nonlinear Power System Transient Dynamics

Power system stability and control have become more challenging due to the increasing uncertainty associated with renewable generation. Here, the performance of conventional control is highly driven by the physics-based offline-developed dynamic models that can deviate from the actual system characteristics under different operating conditions and/or configurations. Data-driven approaches based on online measurements can be a better solution to addressing these issues by capturing real-time operation conditions. This article describes a novel fully data-driven probabilistic framework to derive a linear representation of postcontingency grid dynamics and online prescribe control based on the derived model to enhance transient stability. The complex nonlinear power system dynamics is approximated by a linear model by using multiple neural network modules that infer distributions of the observations and introducing a Koopman layer to sample possible Koopman linear models from the inferred distributions. The trained model features linearity that can be easily incorporated into the existing linear control design paradigm and ease the controller design process. The effectiveness of Koopman-based control designs is validated through comparative case studies, which demonstrate increased prediction accuracy and control performance when applied to a power system with heterogeneous generator dynamics.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Project Dinos I: A joint lensing–dynamics constraint on the deviation from the power law in the mass profile of massive ellipticals

The mass distribution in massive elliptical galaxies encodes their evolutionary history, thus providing an avenue to constrain the baryonic astrophysics in their evolution. The power-law assumption for the radial mass profile in ellipticals has been sufficient to describe several observables to the noise level, including strong lensing and stellar dynamics. In this paper, we quantitatively constrained any deviation, or the lack thereof, from the power-law mass profile in massive ellipticals through joint lensing–dynamics analysis of a large statistical sample with 77 galaxy–galaxy lens systems. We performed an improved and uniform lens modelling of these systems from archival Hubble Space Telescope imaging using the automated lens modelling pipeline dolphin. We combined the lens model posteriors with the stellar dynamics to constrain the deviation from the power law after accounting for the line-of-sight lensing effects, a first for analyses on galaxy–galaxy lenses. We find that the Sloan Lens ACS Survey lens galaxies with a mean redshift of 0.2 are consistent with the power-law profile within 1.1σ (2.8σ) and the Strong Lensing Legacy Survey lens galaxies with a mean redshift of 0.6 are consistent within 0.8σ (2.1σ), for a spatially constant (Osipkov–Merritt) stellar anisotropy profile. We adopted the spatially constant anisotropy profile as our baseline choice based on previous dynamical observables of local ellipticals. However, spatially resolved stellar kinematics of lens galaxies are necessary to differentiate between the two anisotropy models. Future studies will use our lens models to constrain the mass distribution individually in the dark matter and baryonic components.

79 ASTRONOMY AND ASTROPHYSICS↗

Modular Hydronic Room Conditioning System (CRADA NFE-24-10120 Final Report)

This project presents the development and validation of high-fidelity numerical models for fin-tube heat exchangers to enable accurate performance prediction and informed design optimization. The modeling framework integrates detailed geometric specifications, thermophysical property data, and system-level constraints to simulate the heat exchanger’s behavior under a range of operating conditions. The model is calibrated using real-world product specifications and validated against experimental data collected from controlled cooling and heating tests. In cooling mode, the model captures the overall trends in capacity and outlet air temperature but tends to underpredict latent effects, especially at lower air flow rates. In heating mode, the simulation consistently overestimates both the thermal capacity and outlet air temperature, indicating the need for refinement in air-side heat transfer assumptions. Despite these deviations, the model provides a solid foundation for optimization, allowing key design variables to be tuned within physical and performance-based constraints. This research advances the ability to simulate, validate, and optimize fin-tube heat exchanger designs with greater confidence and efficiency.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Modular Hydronic Room Conditioning System

This project presents the development and validation of high-fidelity numerical models for fin-tube heat exchangers to enable accurate performance prediction and informed design optimization. The modeling framework integrates detailed geometric specifications, thermophysical property data, and system-level constraints to simulate the heat exchanger’s behavior under a range of operating conditions. The model is calibrated using real-world product specifications and validated against experimental data collected from controlled cooling and heating tests. In cooling mode, the model captures the overall trends in capacity and outlet air temperature but tends to underpredict latent effects, especially at lower air flow rates. In heating mode, the simulation consistently overestimates both the thermal capacity and outlet air temperature, indicating the need for refinement in air-side heat transfer assumptions. Despite these deviations, the model provides a solid foundation for optimization, allowing key design variables to be tuned within physical and performance-based constraints. This research advances the ability to simulate, validate, and optimize fin tube heat exchanger designs with greater confidence and efficiency.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Irreversible Electroporation of Renal Cell Carcinoma: A First-in-Man Phase I Clinical Study

Purpose: Irreversible electroporation (IRE) is a newly developed nonthermal tissue-ablation technique in which high-voltage electrical pulses of microsecond duration are applied to induce irreversible permeabilisation of the cell membrane, presumably through nanoscale defects in the lipid bilayer, leading to apoptosis. The purpose of this study was to assess the feasibility and safety of ablating renal cell carcinoma (RCC) tissue by IRE. Methods: Six patients scheduled for curative resection of RCC were included. IRE was performed during anaesthesia immediately before the resection with electrographic synchronisation. Central haemodynamics were recorded before and 5 min after electroporation. Five-channel electrocardiography (ECG) was used for detailed analysis of ST waveforms. Blood sampling and 12-lead ECG were performed before, during, and at scheduled intervals after the intervention. Results: Analysis of ST waveforms and axis deviations showed no relevant changes during the entire study period. No changes in central haemodynamics were seen 5 min after IRE. Similarly, haematological, serum biochemical, and ECG variables showed no relevant differences during the investigation period. No changes in cardiac function after IRE therapy were found. One case of supraventricular extrasystole was encountered. Initial histopathologic examination showed no immediate adverse effects of IRE (observation of delayed effects will require a different study design). Conclusion: IRE seems to offer a feasible and safe technique by which to treat patients with kidney tumours and could offer some potential advantages over current thermal ablative techniques.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Learning Topological Operations on Meshes with Application to Block Decomposition of Polygons

We present a learning based framework for mesh quality improvement on unstructured triangular and quadrilateral meshes. Our model learns to improve mesh quality according to a prescribed objective function purely via self-play reinforcement learning with no prior heuristics. The actions performed on the mesh are standard local and global element operations. The goal is to minimize the deviation of the node degrees from their ideal values, which in the case of interior vertices leads to a minimization of irregular nodes.

97 MATHEMATICS AND COMPUTING↗

Frameless Angiogram-Based Stereotactic Radiosurgery for Treatment of Arteriovenous Malformations

Purpose: Stereotactic radiosurgery (SRS) is an effective alternative to microsurgical resection or embolization for definitive treatment of arteriovenous malformations (AVMs). Digital subtraction angiography (DSA) is the gold standard for pretreatment diagnosis and characterization of vascular anatomy, but requires rigid frame (skull) immobilization when used in combination with SRS. With the advent of advanced proton and image-guided photon delivery systems, SRS treatment is increasingly migrating to frameless platforms, which are incompatible with frame-based DSA. Without DSA as the primary image, target definition may be less than optimal, in some cases precluding the ability to treat with a frameless system. This article reports a novel solution. Methods and Materials: Fiducial markers are implanted into the patient's skull before angiography. Angiography is performed according to the standard clinical protocol, but, in contrast to the previous practice, without the rigid frame. Separate images of a specially designed localizer box are subsequently obtained. A target volume projected on DSA can be transferred to the localizer system in three dimensions, and in turn be transferred to multiple CT slices using the implanted fiducials. Combined with other imaging modalities, this 'virtual frame' approach yields a highly precise treatment plan that can be delivered by frameless SRS technologies. Results: Phantom measurements for point and volume targets have been performed. The overall uncertainty of placing a point target to CT is 0.4 mm. For volume targets, deviation of the transformed contour from the target CT image is within 0.6 mm. The algorithm and software are robust. The method has been applied clinically, with reliable results. Conclusions: A novel and reproducible method for frameless SRS of AVMs has been developed that enables the use of DSA without the requirement for rigid immobilization. Multiple pairs of DSA can be used for better conformality. Further improvement, including using nonimplanted fiducials, is potentially feasible.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

High-Resolution Measurement of Soil Thermal Properties and Moisture Content Using a Novel Heated Fiber Optics Approach

Hydrological parameters are scale dependent. Efficient monitoring techniques capable of measuring hydrological parameters, such as soil moisture content (θ), over a wide range of spatial scales are essential for understanding the complexity of water and energy movement across the landscape. Techniques to measure θ over spatial scales in the range from centimeters to thousands of meters, however, are sorely lacking. Recent improvements in the distributed temperature sensing (DTS) technology supported the development of novel techniques to fill that gap. However, improvements in the accuracy and applicability of DTS techniques are still needed. This study investigates the possibility of improving the accuracy of the fiber optics dual-probe heat-pulse (FO-DPHP) DTS technique by using a new design to maintain the spacing between the FO-DPHP probes and by introducing a novel data interpretation approach. The accuracy of the novel FO-DPHP design was tested at different θ in a sand column experiment. The FO-DPHP measurements obtained using traditional and novel data interpretation approaches were compared against independent measurements from several calibrated soil water content (EC5) sensors. Monte-Carlo analyses were also performed to assess the impact of DTS measurement errors on the accuracy achieved using the data interpretation approaches. The novel design and data interpretation approach allowed for accurate measurements of soil thermal properties and θ without the need to perform a hard-to-achieve soil-specific calibration. Measured θ had mean errors and standard deviations <0.03 and <0.01 m 3 m -3 , respectively, for moisture conditions ranging from dry to near saturation. The standard deviation in the measured heat capacity was <0.01 MJ m -3 K -1 .

42 ENGINEERING↗

Multi-reference vibration correlation methods

State-specific vibration correlation methods beyond the vibrational multi-configuration self-consistent field (VMCSCF) approximation have been developed, which allow for the accurate calculation of state energies for systems suffering from strong anharmonic resonances. Both variational multi-reference configuration interaction approaches and an implementation of approximate 2nd order vibrational multi-reference perturbation theory are presented. The variational approach can be significantly accelerated by a configuration selection scheme, which leads to negligible deviations in the final results. Relaxation effects due to the partitioning of the correlation space and the performance of a VMCSCF modal basis in contrast to a standard modal basis obtained from vibrational self-consistent field theory have been investigated in detail. Benchmark calculations based on high-level potentials are provided for the propargyl cation and cis-diazene.

74 ATOMIC AND MOLECULAR PHYSICS↗

Evaluation of the grand-canonical partition function using expanded Wang-Landau simulations. III. Impact of combining rules on mixtures properties

Combining rules, such as the Lorentz-Berthelot rules, are routinely used to calculate the thermodynamic properties of mixtures using molecular simulations. Here we extend the expanded Wang-Landau simulation approach to determine the impact of the combining rules on the value of the partition function of binary systems, and, in turn, on the phase coexistence and thermodynamics of these mixtures. We study various types of mixtures, ranging from systems of rare gases to biologically and technologically relevant mixtures, such as water-urea and water-carbon dioxide. Comparing the simulation results to the experimental data on mixtures of rare gases allows us to rank the performance of combining rules. We find that the widely used Lorentz-Berthelot rules exhibit the largest deviations from the experimental data, both for the bulk and at coexistence, while the Kong and Waldman-Hagler provide much better alternatives. In particular, in the case of aqueous solutions of urea, we show that the use of the Lorentz-Berthelot rules has a strong impact on the Gibbs free energy of the solute, overshooting the value predicted by the Waldman-Hagler rules by 7%. This result emphasizes the importance of the combining rule for the determination of hydration free energies using molecular simulations.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Ab initio explanation of disorder and off-stoichiometry in Fe-Mn-Al-C κ carbides

Carbides play a central role for the strength and ductility in many materials. Simulating the impact of these precipitates on the mechanical performance requires knowledge about their atomic configuration. In particular, the C content is often observed to substantially deviate from the ideal stoichiometric composition. In this work, we focus on Fe-Mn-A1-C steels, for which we determined the composition of the nanosized κ carbides (Fe,Mn) 3 AlC by atom probe tomography in comparison to larger precipitates located in grain boundaries. Combining density functional theory with thermodynamic concepts, we first determine the critical temperatures for the presence of chemical and magnetic disorder in these carbides. Second, the experimentally observed reduction of the C content is explained as a compromise between the gain in chemical energy during partitioning and the elastic strains emerging in coherent microstructures.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Photo response of 164 Dy

Background: Little data is available for the pygmy dipole resonance (PDR) in axially deformed nuclei. Photon-scattering experiments are complicated by high level densities in the PDR region and the small energy difference of transitions to the ground state and to excited states. Purpose: In this work, we report on an experimental study of the low-energy dipole strength distribution of the well-deformed nucleus 164 Dy between 4.0–7.7 MeV. Methods: The low-lying photoresponse of 164 Dy has been investigated using the method of nuclear resonance fluorescence using a quasimonochromatic linearly polarized $\textit{γ}$-ray beam in the energy range of 4.0–7.7 MeV in steps of 0.2 MeV. Results: For excitation energies between 4 MeV and 5 MeV, sufficiently low level densities allow for the identification of individual states, including level energies, reduced transition widths and branching ratios. Energy-averaged mean decay branching ratios, mean population ratios and partial absorption cross sections were determined above 5 MeV up to the neutron-separation threshold at 7.7 MeV. A Lorentzian-shaped enhancement of the partial photo absorption cross section followed by decays back to the ground-state band is found at 6.10(5) MeV with a width of 0.77(23) MeV. A comparison with results from complementary measurements is performed using the framework of the statistical model. Conclusions: The experimental results for the mean population ratios deviate systematically from the statistical model simulation by 30(6)%. However, they are in agreement within one standard deviation of the simulation.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Precise and accurate determination of the {sup 8}B decay spectrum

Accurate measurements of the {sup 8}B neutrino spectrum are important for the interpretation of solar neutrino data. Experimentally, the {sup 8}B neutrino spectrum can be obtained from the measurement of the {beta}-delayed {alpha} spectrum. We report on an {alpha}-{alpha} coincidence measurement performed at the IGISOL facility in Jyvaeskylae, Finland. Our measurement allows extensive cross-checks to be performed and gives a more intense neutrino spectrum at high energies compared to the present standard. The deviation reaches 4% at the end point of the spectrum. Below 11 MeV, the deviation is less than 1%.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Performance of the upgraded ultracold neutron source at Los Alamos National Laboratory and its implication for a possible neutron electric dipole moment experiment

We report the ultracold neutron (UCN) source at Los Alamos National Laboratory (LANL), which uses solid deuterium as the UCN converter and is driven by accelerator spallation neutrons, has been successfully operated for over 10 years, providing UCN to various experiments, as the first production UCN source based on the superthermal process. It has recently undergone a major upgrade. This paper describes the design and performance of the upgraded LANL UCN source. Measurements of the cold neutron spectrum and UCN density are presented and compared to Monte Carlo predictions. The source is shown to perform as modeled. The UCN density measured at the exit of the biological shield was 184(32) UCN / cm 3 , a fourfold increase from the highest previously reported. Finally, the polarized UCN density stored in an external chamber was measured to be 39(7) UCN / cm 3 , which is sufficient to perform an experiment to search for the nonzero neutron electric dipole moment with a one-standard-deviation sensitivity of σ(d n ) = 3 × 10 -27 e cm.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Measurement of Anomalously Strong Emission from the 1s-9p Transition in the Spectrum of H-Like Phosphorus Following Charge Exchange with Molecular Hydrogen

We have measured K-shell x-ray spectra of highly ionized argon and phosphorus following charge exchange with molecular hydrogen at low collision energy in an electron beam ion trap using an x-ray calorimeter array with {approx}6 eV resolution. We find that the emission at the high end of the Lyman series is greater by a factor of 2 for phosphorus than for argon, even though the measurement was performed concurrently and the atomic numbers are similar. This does not agree with current theoretical models and deviates from the trend observed in previous measurements.

74 ATOMIC AND MOLECULAR PHYSICS↗

SU-E-T-436: Fluence-Based Trajectory Optimization for Non-Coplanar VMAT

Purpose: To investigate a fluence-based trajectory optimization technique for non-coplanar VMAT for brain cancer. Methods: Single-arc non-coplanar VMAT trajectories were determined using a heuristic technique for five patients. Organ at risk (OAR) volume intersected during raytracing was minimized for two cases: absolute volume and the sum of relative volumes weighted by OAR importance. These trajectories and coplanar VMAT formed starting points for the fluence-based optimization method. Iterative least squares optimization was performed on control points 24° apart in gantry rotation. Optimization minimized the root-mean-square (RMS) deviation of PTV dose from the prescription (relative importance 100), maximum dose to the brainstem (10), optic chiasm (5), globes (5) and optic nerves (5), plus mean dose to the lenses (5), hippocampi (3), temporal lobes (2), cochleae (1) and brain excluding other regions of interest (1). Control point couch rotations were varied in steps of up to 10° and accepted if the cost function improved. Final treatment plans were optimized with the same objectives in an in-house planning system and evaluated using a composite metric - the sum of optimization metrics weighted by importance. Results: The composite metric decreased with fluence-based optimization in 14 of the 15 plans. In the remaining case its overall value, and the PTV and OAR components, were unchanged but the balance of OAR sparing differed. PTV RMS deviation was improved in 13 cases and unchanged in two. The OAR component was reduced in 13 plans. In one case the OAR component increased but the composite metric decreased - a 4 Gy increase in OAR metrics was balanced by a reduction in PTV RMS deviation from 2.8% to 2.6%. Conclusion: Fluence-based trajectory optimization improved plan quality as defined by the composite metric. While dose differences were case specific, fluence-based optimization improved both PTV and OAR dosimetry in 80% of cases.

60 APPLIED LIFE SCIENCES↗

Technical Note: Phantom study to evaluate the dose and image quality effects of a computed tomography organ-based tube current modulation technique

Purpose: This technical note quantifies the dose and image quality performance of a clinically available organ-dose-based tube current modulation (ODM) technique, using experimental and simulation phantom studies. The investigated ODM implementation reduces the tube current for the anterior source positions, without increasing current for posterior positions, although such an approach was also evaluated for comparison. Methods: Axial CT scans at 120 kV were performed on head and chest phantoms on an ODM-equipped scanner (Optima CT660, GE Healthcare, Chalfont St. Giles, England). Dosimeters quantified dose to breast, lung, heart, spine, eye lens, and brain regions for ODM and 3D-modulation (SmartmA) settings. Monte Carlo simulations, validated with experimental data, were performed on 28 voxelized head phantoms and 10 chest phantoms to quantify organ dose and noise standard deviation. The dose and noise effects of increasing the posterior tube current were also investigated. Results: ODM reduced the dose for all experimental dosimeters with respect to SmartmA, with average dose reductions across dosimeters of 31% (breast), 21% (lung), 24% (heart), 6% (spine), 19% (eye lens), and 11% (brain), with similar results for the simulation validation study. In the phantom library study, the average dose reduction across all phantoms was 34% (breast), 20% (lung), 8% (spine), 20% (eye lens), and 8% (brain). ODM increased the noise standard deviation in reconstructed images by 6%–20%, with generally greater noise increases in anterior regions. Increasing the posterior tube current provided similar dose reduction as ODM for breast and eye lens, increased dose to the spine, with noise effects ranging from 2% noise reduction to 16% noise increase. At noise equal to SmartmA, ODM increased the estimated effective dose by 4% and 8% for chest and head scans, respectively. Increasing the posterior tube current further increased the effective dose by 15% (chest) and 18% (head) relative to SmartmA. Conclusions: ODM reduced dose in all experimental and simulation studies over a range of phantoms, while increasing noise. The results suggest a net dose/noise benefit for breast and eye lens for all studied phantoms, negligible lung dose effects for two phantoms, increased lung dose and/or noise for eight phantoms, and increased dose and/or noise for brain and spine for all studied phantoms compared to the reference protocol.

60 APPLIED LIFE SCIENCES↗