Electrochemical Modeling of PID Leakage Current of PV Modules: Steady-State Current, Transient Current, and RC-Equivalent Circuit

Potential-induced degradation (PID) remains a significant reliability concern for photovoltaic (PV) modules, arising when a voltage difference between the module frame and the solar cells drives unintended leakage current through the glass-encapsulant stack. Although PID ultimately manifests as PID-s, PID-p, or PID-c, the underlying behavior of the leakage current-its magnitude and time dependence-requires clearer electrochemical interpretation. Traditional explanations attribute the initial transient current to bulk capacitive elements of the glass, encapsulant, and antireflection coatings, and the steady-state current according to their effective ohmic resistance. More recent studies, however, indicate that electrochemical charge-transfer processes at the encapsulant-metallization interface can play a dominant role in defining the leakage-current path. This paper develops a unified electrochemical framework for modeling PID leakage current. First, an RC-equivalent circuit is formulated by combining conventional RC elements with a Randles-type interface to capture transient leakage current through double-layer capacitance and faradaic processes at ionic-electronic boundaries. Second, the steady-state current-voltage behavior is explained using a linearized Butler-Volmer relationship, showing that the measured ohmic response corresponds to the low-overpotential limit of charge-transfer kinetics. Analytical results demonstrate that, for typical module materials-3.2-mm soda-lime glass and 0.45-mm encapsulant-the dominant modulators to PID leakage current are the glass surface resistance (under dry-surface conditions), the glass bulk capacitance, and the encapsulant resistance (under wet-surface conditions), with soda lime glass surface and EVA/POE encapsulant resistances primarily governing steady-state current. The proposed electrochemical model is validated against measured leakage-current data, showing good agreement in both the magnitude and the time-dependent evolution of PID leakage current.

14 SOLAR ENERGY↗

Results from an international interlaboratory study on light‐ and elevated temperature‐induced degradation in solar modules

Abstract This paper reports the results of an international interlaboratory comparison study on light‐ and elevated temperature‐induced degradation (LETID) on crystalline silicon photovoltaic (PV) modules. A large global network of PV module manufacturers and PV testing laboratories collaborated to design a protocol for LETID detection and screen a large and diverse set of prototype modules for LETID. Results across labs indicate the reproducibility of LETID testing is likely within ±1% of maximum power (P MP ). In intentionally engineered LETID‐sensitive modules, mean degradation after the prescribed detection stress is roughly 6% P MP . In other module types the LETID sensitivity is smaller, and in some we observe essentially negligible degradation attributable to LETID. In LETID‐sensitive modules, both open‐circuit voltage (V OC ) and short‐circuit current (I SC ) degrade by a roughly similar magnitude. We observe, as do previous studies, that LETID affects each cell in a module differently. An investigation of the potential mismatch losses caused by nonuniform LETID degradation found that mismatch loss is insignificant compared to the estimated loss of cell I SC , which drives loss of module I SC . Overall, this work has helped inform the creation of a forthcoming standard technical specification for LETID testing of PV modules, IEC TS 63342 ED1, and should aid in the interpretation of results from that and other LETID tests.

14 SOLAR ENERGY↗

In-Situ Measurement of Power Loss for Crystalline Silicon Modules Undergoing Thermal Cycling and Mechanical Loading Stress Testing

An in-situ method is proposed for monitoring and estimating the power degradation of mc-Si photovoltaic (PV) modules undergoing thermo-mechanical degradation tests that primarily manifest through cell cracking, such as mechanical load tests, thermal cycling and humidity freeze tests. The method is based on in-situ measurement of the module’s dark current-voltage (I-V) characteristic curve during the stress test, as well as initial and final module flash testing on a Sun simulator. The method uses superposition of the dark I-V curve with final flash test module short-circuit current to account for shunt and junction recombination losses, as well as series resistance estimation from the in-situ measured dark I-Vs and final flash test measurements. The method is developed based on mc-Si standard modules undergoing several stages of thermo-mechanical stress testing and degradation, for which we investigate the impact of the degradation on the modules light I-V curve parameters, and equivalent solar cell model parameters. Experimental validation of the method on the modules tested shows good agreement between the in-situ estimated power degradation and the flash test measured power loss of the modules, of up to 4.31 % error (RMSE), as the modules experience primarily junction defect recombination and increased series resistance losses. However, the application of the method will be limited for modules experiencing extensive photo-current degradation or delamination, which are not well reflected in the dark I-V characteristic of the PV module.

14 SOLAR ENERGY↗

Photovoltaic Shading Testbed for Module-Level Power Electronics: 2016 Performance Data Update

The 2012 NREL report 'Photovoltaic Shading Testbed for Module-Level Power Electronics' provides a standard methodology for estimating the performance benefit of distributed power electronics under partial shading conditions. Since the release of the report, experiments have been conducted for a number of products and for different system configurations. Drawing from these experiences, updates to the test and analysis methods are recommended. Proposed changes in data processing have the benefit of reducing the sensitivity to measurement errors and weather variability, as well as bringing the updated performance score in line with measured and simulated values of the shade recovery benefit of distributed PV power electronics. Also, due to the emergence of new technologies including sub-module embedded power electronics, the shading method has been extended to include power electronics that operate at a finer granularity than the module level. An update to the method is proposed to account for these emerging technologies that respond to shading differently than module-level devices. The partial shading test remains a repeatable test procedure that attempts to simulate shading situations as would be experienced by typical residential or commercial rooftop photovoltaic (PV) systems. Performance data for multiple products tested using this method are discussed, based on equipment from Enphase, Solar Edge, Maxim Integrated and SMA. In general, the annual recovery of shading losses from the module-level electronics evaluated is 25-35%, with the major difference between different trials being related to the number of parallel strings in the test installation rather than differences between the equipment tested. Appendix D data has been added in this update.

14 SOLAR ENERGY↗

PV Lifetime Project: Measuring PV Module Performance Degradation: 2018 Indoor Flash Testing Results

Photovoltaic (PV) module and system performance degradation is being measured by periodic flash testing of fielded PV modules at three sites. As of early 2018, results from modules fielded in New Mexico and Colorado are now available. These data indicate that module degradation varies significantly between module types and can also vary between modules of the same model. In addition, degradation rates for some module types appear to vary over time. Great care is made to control for stability and repeatability in the measurements over time, but there is still a +/-0.5% uncertainty in flash test stability. Therefore, it will take several more years for degradation rate results to be known with higher confidence.

14 SOLAR ENERGY↗

Port of Galveston Solar Energy Project

This study on the performance characteristics of existing solar technologies in a maritime environment was funded by an award given to The Port of Galveston (POG) from the U.S. Department of Energy (DOE). The study includes research performed by The Center for Advanced Materials at the University of Houston (UH). The UH researchers examined how solar cell efficiencies and life spans can be improved by examining the performance of a variety of antireflective (AR) coatings mounted on the top of one of the POG’s Cruise Terminals. Supplemental supporting research was performed at the UH laboratories. An educational Kiosk was constructed with a 55” display screen providing information about solar energy, the research work UH performed at POG and real time data from the solar panels located on the roof of the Cruise Terminal. The Houston Advanced Research Center (HARC) managed the project.

14 SOLAR ENERGY↗

Evaluation of Models and Measurements to Estimate Solar Radiation for 1-Axis Tracking Modules at NREL’s SRRL

Solar radiation reaching photovoltaic (PV) modules on a 1-axis tracking system can be measured by reference cells or thermopiles. The former is often biased due to the reflection of solar radiation by the glass cover of the PV. The uncertainty can be moderated by applying a correction factor, as a function of solar incident angle and the refractive index of the glass, to the measurement. On the other hand, solar radiation on the inclined PV panels can be computed by transposition models using global horizontal irradiance (GHI) observations from thermopiles. This study examines the models and measurements to estimate solar radiation for 1-axis tracking modules at the National Renewable Energy Laboratory’s (NREL’s) Solar Radiation Research Laboratory (SRRL). The 1-minute plane-of-array (POA) irradiances from 2019 are computed using the observed GHIs and a transposition model developed by Perez et al. The POA irradiances are compared with the observation by an IMT reference cell and a Kipp & Zonen CM Pyranometer 22 (CMP22) thermopile. For the SRRL’s 1-axis tracking system with an annual solar energy of 2323.9 kWh/m 2 , the POA irradiance is overestimated by ~70 kWh/m 2 using the transposition model. This bias is reduced by more than 50% using the IMT measurements calibrated by a correction factor for a PV surface of antireflection coated glass.

POA irradiance↗

Effectiveness of Rain Cleaning on Artificially Soiled PV Modules With and Without Anti-Soiling Coatings

A simple, inexpensive methodology for testing the effectiveness of rain cleaning on artificially soiled single-cell and multi-cell photovoltaic (PV) modules having anti-soiling coatings has been developed. Using an indoor soil deposition chamber and methodology as described in our previously published work, multiple layers of soil were deposited on to the glass surface of single-cell PV modules subjected to controlled temperature and humidity cycles. Three single-cell monocrystalline PV modules are reported in this study, two of which had different anti-soiling (AS) coatings applied to the surface and the third did not have any AS coating. The set-up and operation of a rain-simulator is described as well as the rain cleaning parameters the PV test modules were exposed to. The purpose of this work is to determine the effectiveness of anti-soiling coatings and cleaning techniques, so vendor claims can be quantitatively validated using an appropriately controlled soil deposition chamber and a rain simulating spray nozzle.

14 SOLAR ENERGY↗

Estimating the Effects of Module Area on Thin-Film Photovoltaic System Costs

We investigate the potential effects of module area on the cost and performance of photovoltaic systems. Applying a bottom-up methodology, we analyzed the costs associated with thin-film modules and systems as a function of module area. We calculate a potential for savings of up to 0.10/Wand0.13/W in module manufacturing costs for CdTe and CIGS respectively, with large area modules. We also find that an additional 0.04/W savings in balance-of-systems costs may be achieved. Sensitivity of the /W cost savings to module efficiency, manufacturing yield, and other parameters is presented. Lifetime energy yield must also be maintained to realize reductions in the levelized cost of energy; the effects of module size on energy yield for monolithic thin-film modules are not yet well understood. Finally, we discuss possible non-cost barriers to adoption of large area modules.

14 SOLAR ENERGY↗

A study of Cell Cracks Formation During Freight Shipping : Monitoring Shock and Temperature in Real-Time & Assessing Damages With Pre and Post-Transit Characterizations of PV Modules

The solar photovoltaic (PV) industry often experiences module damage during transportation. PV modules stacked horizontally and strapped on wooden pallets may develop failures impacting their efficiency (glass shattering, cracks, frame indentation, etc.), especially when modules are not packed by professionals. The appearance of failures during the shipment from one laboratory to another can be detrimental to research studies. In this study, we tested a reusable plastic pallet designed to ship modules vertically. Five technologies of commercial PV modules were shipped together from Arizona to Florida including: glass/glass bifacial modules (framed and frameless), glass/transparent backsheet bifacial modules and glass/white backsheet modules (framed). Each module technology has a different physical size. Some modules had pre-existing cell-cracks allowing for the study of cell-crack formation and propagation during shipment. Dark current-voltage (I-V), light I-V and electroluminescence characterization were performed before and after shipment. A datalogger was used to monitor shocks and ambient temperature throughout the shipment and identify when the modules were more susceptible to damage. The modules were tilted upon receipt and the pallet were damaged but with no shattered modules. Time series shock data provided by the datalogger were used to determine potential responsible events. Our results reveal a few new post-transportation cracks for some modules. Modules parameters before and after shipment are also compared regarding the module constructions and their position in the pallet.

14 SOLAR ENERGY↗

Soiling Related Abrasion and the Development of a PV Abrasion Standard

The natural soiling and consequent cleaning of photovoltaic (PV) modules result in abrasion damage to the cover glass. The durability of the front glass has important economic consequences, including the use of antireflective and/or antisoiling coatings as well as the method and frequency of cleaning-maintenance. The abrasion of glass and coated glass has been explored in a field study, including the soiling-prone locations of: Dubai (United Arab Emirates), Kuwait city (Kuwait), Mesa (Arizona), Mumbai (India), and Sacramento (California). Dry brush cleaned specimens will be compared to those subject to artificial brush testing or falling sand abrasion. The characteristics of material integrity, optical transmittance, surface energy, surface roughness, and scratch size were examined using an optical microscope, spectrophotometer, contact goniometer (for water), interferometer, and atomic force microscope, respectively. The findings of this study will be used to provide feedback regarding the cleaning equipment, cleaning methods, and coatings used in the PV industry. The study here will also be used to aid the development of an abrasion standard for the PV industry.

14 SOLAR ENERGY↗

BACKFLIP: Identification of Materials and Changes Upon Aging of Emerging Fluoropolymer-Free and Industry-Benchmark PV Backsheets

Extending lifetimes of photovoltaic (PV) modules and decreasing manufacturing and decommissioning costs are motivating research of novel PV module backsheet materials. Backsheet integrity is critical to the safety and performance of a PV module, however, the polymeric materials are often vulnerable to environmental degradation. The long-term durability of emerging polyolefin (PO) materials is being examined to inform regarding the possible replacement of laminated backsheets containing polyethylene terephthalate (PET) cores and fluoropolymer protective inner/outer layers. This study compares traditional PET-based backsheets with novel, co-extruded, and recyclable PO-based backsheets after being subjected to hygrometric and UV photolytic accelerated weathering. A large set of characterization methods will compare physical, chemical, structural, mechanical, and insulating properties of these backsheets and the resulting mini-module (MiMo) PV performances. The study of chemical composition, glass- and phase-transition temperatures, degree of crystallinity, and crystalline structure are described here.

mini-module↗

Estimating the Effects of Module Area on Thin-Film Photovoltaic System Costs: Preprint

We investigate the potential effects of module area on the cost and performance of photovoltaic systems. Applying a bottom-up methodology, we analyzed the costs associated with thin-film modules and systems as a function of module area. We calculate a potential for savings of up to 0.10 dollars/W and 0.13 dollars/W in module manufacturing costs for CdTe and CIGS respectively, with large area modules. We also find that an additional 0.04 dollars/W savings in balance-of-systems costs may be achieved. Sensitivity of the dollar/W cost savings to module efficiency, manufacturing yield, and other parameters is presented. Lifetime energy yield must also be maintained to realize reductions in the levelized cost of energy; the effects of module size on energy yield for monolithic thin-film modules are not yet well understood. Finally, we discuss possible non-cost barriers to adoption of large area modules.

14 SOLAR ENERGY↗

Validation of SolarWorld Modules at the NREL Regional Test Center Site (CRADA CRD-15-595 Final Report)

SolarWorld and the National Renewable Energy Laboratory (NREL) are entering into a cooperative research and development agreement (CRADA) in order to perform validation testing of SolarWorld’s Photovoltaic (PV) modules through the Department of Energy (DOE) Regional Test Center (RTC) program. This CRADA describes testing activities conducted specifically at the NREL-managed Colorado RTC site.

14 SOLAR ENERGY↗

Performance Modelling and Yearlong Outdoor Degradation Analysis of a GaAs//Si Tandem Module

Silicon-based tandem photovoltaic cells and modules are forecasted to enter mass production around the year 2026. Previous research efforts on tandem photovoltaic technology have focused heavily on increasing cell efficiencies. However, for successful large-scale deployment of tandem modules, reliability and long-term durability will be equally important. Outdoor performance data beyond the one-year mark enable sophisticated degradation analysis and help build confidence in the reliability and durability of this new technology.

degradation rate↗

Evaluation of Models and Measurements to Estimate Solar Radiation for 1-Axis Tracking Modules at NREL's SRRL: Preprint

Solar radiation reaching photovoltaic (PV) modules on a 1-axis tracking system can be measured by reference cells or thermopiles. The former is often biased due to the reflection of solar radiation by the glass cover of the PV. The uncertainty can be moderated by applying a correction factor, as a function of solar incident angle and the refractive index of the glass, to the measurement. On the other hand, solar radiation on the inclined PV panels can be computed by transposition models using global horizontal irradiance (GHI) observations from thermopiles. This study examines the models and measurements to estimate solar radiation for 1-axis tracking modules at National Renewable Energy Laboratory’s (NREL’s) Solar Radiation Research Laboratory (SRRL). The 1-minute plane-of-array (POA) irradiances in 2019 are computed using the observed GHIs and a transposition model developed by Perez et al. The POA irradiances are compared with the observation by an IMT reference cell and a Kipp & Zonen CM Pyranometer 22 (CMP22) thermopile. For SRRL’s 1-axis tracking system with the annual solar energy of 2323.9 kWh/m2, the POA irradiance is overestimated by ~70 kWh/m2 using the transposition model. This bias is reduced by more than 50% using the IMT measurements calibrated by a correction factor for a PV surface of antireflection coated glass.