Search NASA⌕ Search

SEARCH · Search NASA

Results for “Position Sensitive Detector”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 721 records · Page 40

The TAIGA Experiment: From Cosmic Ray Physics to Gamma Astronomy in the Tunka Valley

The article presents the relevance and advantages of the new gamma observatory TAIGA (Tunka Advanced Instrument for cosmic ray physics and Gamma Astronomy), which is being constructed in the Tunka Valley 50 km from Lake Baikal. Various detectors of the six TAIGA gamma observatory arrays register the Cherenkov and radio radiation, as well as the electron and muon components of EAS. The primary objective of the TAIGA gamma observatory is to study the high-energy part of the gamma-ray spectrum, in particular, in order to search for Galactic PeVatrons. The energy, direction, and position of the EAS axis are reconstructed in the observatory based on the data of the wide-angle Cherenkov detectors of the TAIGA-HiSCORE experiment. Taking into account this information, the gamma quanta are distinguished from the hadron background using the data obtained by the muon detectors and telescopes that register the EAS image in the Cherenkov light. In this hybrid mode of operation, the atmospheric Cherenkov telescopes can operate in the mono-mode, and the distance between them can be increased to 800–1000 m, which makes it possible to construct an array with an area of 5 km{sup 2} and more at relatively low cost and in a short time. By 2019, the first stage of the gamma observatory with an area of 1 km{sup 2} will be constructed; its expected integral sensitivity for detecting the gamma radiation with an energy of 100 TeV at observation of the source for 300 hours will be approximately 2×5 10{sup –13} TeV cm{sup –2}s{sup –1}.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

SU-E-T-591: Measurement and Monte Carlo Simulation of Stray Neutrons in Passive Scattering Proton Therapy: Needs and Challenges

Purpose: Measure stray radiation inside a passive scattering proton therapy facility, compare values to Monte Carlo (MC) simulations and identify the actual needs and challenges. Methods: Measurements and MC simulations were considered to acknowledge neutron exposure associated with 75 MeV ocular or 180 MeV intracranial passively scattered proton treatments. First, using a specifically-designed high sensitivity Bonner Sphere system, neutron spectra were measured at different positions inside the treatment rooms. Next, measurement-based mapping of neutron ambient dose equivalent was fulfilled using several TEPCs and rem-meters. Finally, photon and neutron organ doses were measured using TLDs, RPLs and PADCs set inside anthropomorphic phantoms (Rando, 1 and 5-years-old CIRS). All measurements were also simulated with MCNPX to investigate the efficiency of MC models in predicting stray neutrons considering different nuclear cross sections and models. Results: Knowledge of the neutron fluence and energy distribution inside a proton therapy room is critical for stray radiation dosimetry. However, as spectrometry unfolding is initiated using a MC guess spectrum and suffers from algorithmic limits a 20% spectrometry uncertainty is expected. H*(10) mapping with TEPCs and rem-meters showed a good agreement between the detectors. Differences within measurement uncertainty (10–15%) were observed and are inherent to the energy, fluence and directional response of each detector. For a typical ocular and intracranial treatment respectively, neutron doses outside the clinical target volume of 0.4 and 11 mGy were measured inside the Rando phantom. Photon doses were 2–10 times lower depending on organs position. High uncertainties (40%) are inherent to TLDs and PADCs measurements due to the need for neutron spectra at detector position. Finally, stray neutrons prediction with MC simulations proved to be extremely dependent on proton beam energy and the used nuclear models and cross sections. Conclusion: This work highlights measurement and simulation limits for ion therapy radiation protection applications.

07 ISOTOPE AND RADIATION SOURCES↗

SU-F-T-165: Daily QA Analysis for Spot Scanning Beamline

Purpose: The dosimetric results of our daily quality assurance over the last 8 years for discrete pencil beam scanning proton therapy will be presented. Methods: To perform the dosimetric checks, a multi-ion chamber detector is used, which consists of an array of 5 single parallel plate ion chambers that are aligned as a cross separated by 10cm each. The Tracker is snapped into a jig, which is placed on the tabletop. Different amounts of Solid Water buildup are added to shift the dose distribution. The dosimetric checks consist of 3 parts: position check, range check and volume dose check. Results: The average deviation of all position-check data were 0.2±1.3%. For the range check, the average deviation was 0.1%±1.2%, which also corresponds to a range stability of better than 1 mm over all measurements. The volumetric dose output readings were all within ±1% with the exception of 2 occasions when the cable to the dose monitor was being repaired. Conclusion: Morning QA using the Tracker device gives very stable dosimetric readings but is also sensitive to mechanical and output changes in the proton therapy delivery system.

07 ISOTOPE AND RADIATION SOURCES↗

Precise Lamb Shift Measurements in Hydrogen-Like Heavy Ions--Status and Perspectives

The precise determination of the energy of the Lyman {alpha}1 and {alpha}2 lines in hydrogen-like heavy ions provides a sensitive test of quantum electrodynamics in very strong Coulomb fields. For the first time, a calorimetric low-temperature detector was applied in an experiment to precisely determine the transition energy of the Lyman lines of lead ions {sup 207}pb{sup 81+} at the Experimental Storage Ring (ESR) at GSI. The detectors consist of silicon thermistors, provided by the NASA/Goddard Space Flight Center, and Pb or Sn absorbers to obtain high quantum efficiency in the energy range of 40-80 keV, where the Doppler-shifted Lyman lines are located. The measured energy of the Lyman {alpha}1 line, E(Ly-{alpha}1, {sup 207}Pb{sup 81+}) = (77937{+-}12{sub stat}{+-}23{sub syst}) eV, agrees within errors with theoretical predictions. The systematic error is mainly due to uncertainties in the non-linear energy calibration of the detectors as well as the relative position of detector and gas-jet target.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Mean glandular dose estimation using MCNPX for a digital breast tomosynthesis system with tungsten/aluminum and tungsten/aluminum+silver x-ray anode-filter combinations

Breast cancer screening with x-ray mammography, using one or two projection images of the breast, is an indispensible tool in the early detection of breast cancer in women. Digital breast tomosynthesis (DBT) is a 3D imaging technique that promises higher sensitivity and specificity in breast cancer screening at a similar radiation dose to conventional two-view screening mammography. In DBT a 3D volume is reconstructed with anisotropic voxels from a limited number of x-ray projection images acquired over a limited angle. Although the benefit of early cancer detection through screening mammography outweighs the potential risks associated with radiation, the radiation dosage to women in terms of mean glandular dose (MGD) is carefully monitored. This work studies the MGD arising from a prototype DBT system under various parameters. Two anode/filter combinations (W/Al and W/Al+Ag) were investigated; the tube potential ranges from 20 to 50 kVp; and the breast size varied between 4 and 10 cm chest wall-to-nipple distance and between 3 and 7 cm compressed breast thickness. The dosimetric effect of breast positioning with respect to the imaging detector was also reviewed. It was found that the position of the breast can affect the MGD by as much as 5% to 13% depending on the breast size.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

NuGraph2: A Graph Neural Network for Neutrino Event Reconstruction

Neutrino experiments are set to probe some of the most important open questions in physics, from CP violation and the nature of dark matter. The technology of choice for many of these experiments is the liquid argon time projection chamber (LArTPC). In current LArTPC experiments, reconstruction performance often represents a limiting factor for the sensitivity. New developments are therefore needed to unlock the full potential of LArTPC experiments. NuGraph2 is a state of the art Graph Neural Network for reconstruction of data in LArTPC experiments. NuGraph2 utilizes a heterogeneous graph structure, with separate subgraphs of 2D nodes (hits in each plane) connected across planes via 3D nodes (space points). The model provides a consistent description of the neutrino interaction across all planes. NuGraph2 is a multi-purpose network, with a common message-passing attention engine connected to multiple decoders with different classification or regression tasks. These include the classification of detector hits according to the particle type that produced them (semantic segmentation) and the separation of hits from the neutrino interaction from hits due to noise or cosmic-ray background. Additional decoders are being developed, performing tasks such as the regression of the neutrino interaction vertex position. Performance results will be presented based on publicly available samples from MicroBooNE. These include both physics performance metrics, achieving 95% accuracy for semantic segmentation and 98% classification of neutrino hits, as well as computational metrics for training and for inference on CPU or GPU. The status of the NuGraph integration in the LArSoft software framework will be presented, as well as initial studies about model interpretability and injection of domain knowledge.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

NuGraph2: A Graph Neural Network for Neutrino Event Reconstruction

Neutrino experiments are set to probe some of the most important open questions in physics, from CP violation and the nature of dark matter. The technology of choice for many of these experiments is the liquid argon time projection chamber (LArTPC). In current LArTPC experiments, reconstruction performance often represents a limiting factor for the sensitivity. New developments are therefore needed to unlock the full potential of LArTPC experiments. NuGraph2 is a state of the art Graph Neural Network for reconstruction of data in LArTPC experiments. NuGraph2 utilizes a heterogeneous graph structure, with separate subgraphs of 2D nodes (hits in each plane) connected across planes via 3D nodes (space points). The model provides a consistent description of the neutrino interaction across all planes. NuGraph2 is a multi-purpose network, with a common message-passing attention engine connected to multiple decoders with different classification or regression tasks. These include the classification of detector hits according to the particle type that produced them (semantic segmentation) and the separation of hits from the neutrino interaction from hits due to noise or cosmic-ray background. Additional decoders are being developed, performing tasks such as the regression of the neutrino interaction vertex position. Performance results will be presented based on publicly available samples from MicroBooNE. These include both physics performance metrics, achieving 95% accuracy for semantic segmentation and 98% classification of neutrino hits, as well as computational metrics for training and for inference on CPU or GPU. The status of the NuGraph integration in the LArSoft software framework will be presented, as well as initial studies about model interpretability and injection of domain knowledge.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Design of a transportable high efficiency fast neutron spectrometer

A transportable fast neutron detection system has been designed and constructed for measuring neutron energy spectra and flux ranging from tens to hundreds of MeV. The transportability of the spectrometer reduces the detector-related systematic bias between different neutron spectra and flux measurements, which allows for the comparison of measurements above or below ground. The spectrometer will measure neutron fluxes that are of prohibitively low intensity compared to the site-specific background rates targeted by other transportable fast neutron detection systems. To measure low intensity high-energy neutron fluxes, a conventional capture-gating technique is used for measuring neutron energies above 20 MeV and a novel multiplicity technique is used for measuring neutron energies above 100 MeV. The spectrometer is composed of two Gd containing plastic scintillator detectors arranged around a lead spallation target. To calibrate and characterize the position dependent response of the spectrometer, a Monte Carlo model was developed and used in conjunction with experimental data from gamma ray sources. Multiplicity event identification algorithms were developed and used with a Cf-252 neutron multiplicity source to validate the Monte Carlo model Gd concentration and secondary neutron capture efficiency. The validated Monte Carlo model was used to predict an effective area for the multiplicity and capture gating analyses. For incident neutron energies between 100 MeV and 1000 MeV with an isotropic angular distribution, the multiplicity analysis predicted an effective area of 500 cm 2 rising to 5000 cm 2 . For neutron energies above 20 MeV, the capture-gating analysis predicted an effective area between 1800 cm 2 and 2500 cm 2 . As a result, the multiplicity mode was found to be sensitive to the incident neutron angular distribution.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A closed-loop phase-locked interferometer for wide bandwidth position sensing

This article describes a position sensitive interferometer with closed-loop control of the reference mirror. A calibrated nanopositioner is used to lock the interferometer phase to the most sensitive point in the interferogram. In this configuration, large low-frequency movements of the sensor mirror can be detected from the control signal applied to the nanopositioner and high-frequency short-range signals can be measured directly from the photodiode. It is demonstrated that these two signals are complementary and can be summed to find the total displacement. The resulting interferometer has a number of desirable characteristics: it is optically simple, does not require polarization or modulation to detect the direction of motion, does not require fringe-counting or interpolation electronics, and has a bandwidth equal to that of the photodiode. Experimental results demonstrate the frequency response analysis of a high-speed positioning stage. The proposed instrument is ideal for measuring the frequency response of nanopositioners, electro-optical components, MEMs devices, ultrasonic devices, and sensors such as surface acoustic wave detectors.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Backaction-evading receivers with magnetomechanical and electromechanical sensors

Today's mechanical sensors are capable of detecting extremely weak perturbations while operating near the standard quantum limit. However, further improvements can be made in both sensitivity and bandwidth when we reduce the noise originating from the process of measurement itself—the quantum-mechanical backaction of measurement—and go below this ‘standard’ limit, possibly approaching the Heisenberg limit. One of the ways to eliminate this noise is by measuring a quantum nondemolition variable such as the momentum in a free-particle system. Here, we propose and characterize theoretical models for direct velocity measurement that utilize traditional electric and magnetic transducer designs to generate a signal while enabling this backaction evasion. We consider the general readout of this signal via electric or magnetic field sensing by creating toy models analogous to the standard optomechanical position-sensing problem, thereby facilitating the assessment of measurement-added noise. Using simple models that characterize a wide range of transducers, we find that the choice of readout scheme—voltage or current—for each mechanical detector configuration implies access to either the position or velocity of the mechanical subsystem. This in turn suggests a path forward for key fundamental physics experiments such as the direct detection of dark matter particles. Published by the American Physical Society 2024

74 ATOMIC AND MOLECULAR PHYSICS↗

SU-C-9A-07: Fabrication and Calibration of a Novel High-Sensitivity Collimator for Brain SPECT Imaging

Purpose: We have designed a novel collimator for brain SPECT imaging that yields greatly increased sensitivity near the center of the brain without loss of resolution. The collimator was manufactured and initial evaluation has been completed. Methods: The collimator was time-consuming and challenging to build. Because our desired hole pattern required substantial variations in hole angle, we designed two supporting plates to securely position about 34,000 hexagonal, slightly tapered, 75-mm long steel pins. The holes in the plates were modeled to yield the desired focal length, hole length and septal thickness. Molten lead was poured in between the plates, and all pins were removed after cooling. The sensitivity gain compared to a fan-beam collimator was measured using a point source placed along the central ray at several distances from the collimator face. Visual inspection of the holes was not possible as the collimator was sealed so it could be safely mounted on a SPECT system. Therefore, we prepared a 2D array of 768, ∼48μCi Tc-99m point sources, separated by 1.6 cm. The array was imaged for 10 minutes at 4 shifted locations to reduce sampling distance to 8 mm. Results: The sensitivity of the novel cone-beam collimator varied with distance from the detector face; it was higher than that of the fan-beam collimator by factors ranging from 3 to 176. Examination of the projections of the 4×768 point sources revealed that fewer than 2% of the holes were fully or partially blocked, which indicates that the intensive manual fabrication process was very successful. Conclusion: We have designed and manufactured a novel collimator for brain SPECT imaging. As expected, the sensitivity is much higher than that of a fan-beam collimator. Because of differences between the manufactured collimator and its design, reconstruction of the data will require a measured system function.

60 APPLIED LIFE SCIENCES↗

A buffer-free concept bubble chamber for PICO dark matter searches

Here, we report on the successful operation at Drexel University of the PICO collaboration's first C 3 F 8 buffer-free prototype fluorocarbon bubble chamber. Previous PICO bubble chambers have produced world-leading WIMP search results with fluorocarbon target fluids, separated from the steel bellows by a buffer layer of water. Surface tension effects at the jar walls and liquid-liquid interface lead to a class of background events which have nuclear-recoil-like acoustic signatures and thus contaminate the WIMP-like signal region in analysis. Thus new bubble chambers are to be constructed “right-side-up”, meaning that the jar of C 3 F 8 is above the bellows with no water inside the inner vessel. The Drexel Bubble Chamber (DBC), runs successfully at and below the nuclear recoil thresholds used by PICO for WIMP searches, including thresholds as low as 1.19 keV . We have demonstrated sensitivity to 137 Cs gammas and spontaneous fission neutrons from 244 Cm, and acoustic alpha discrimination is demonstrated to be possible although the observed rate of alpha decays is very low. Position reconstruction from stereoscopic imaging allows for basic analysis cuts for calibration data. The successful construction and operation of this prototype confirm the effectiveness of the right-side-up design, which will be used in future dark matter searches such as PICO-40L and PICO-500.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Accounting for electron-beam-induced warping of molecular nanocrystals in MicroED structure determination

High-energy electrons induce sample damage and motion at the nanoscale to fundamentally limit the determination of molecular structures by electron diffraction. Using a fast event-based electron counting (EBEC) detector, we characterize beam-induced, dynamic, molecular crystal lattice reorientations (BIRs). These changes are sufficiently large to bring reciprocal lattice points entirely in or out of intersection with the sphere of reflection, occur as early events in the decay of diffracted signal due to radiolytic damage, and coincide with beam-induced migrations of crystal bend contours within the same fluence regime and at the same illuminated location on a crystal. These effects are observed in crystals of biotin, a series of amino acid metal chelates, and a six-residue peptide, suggesting that incident electrons inevitably warp molecular lattices. The precise orientation changes experienced by a given microcrystal are unpredictable but are measurable by indexing individual diffraction patterns during beam-induced decay. Reorientations can often tilt a crystal lattice several degrees away from its initial position before irradiation, and for an especially beam-sensitive Zn(II)-methionine chelate, are associated with dramatic crystal quakes prior to 1 e − Å −2 electron beam fluence accumulates. Since BIR coincides with the early stages of beam-induced damage, it echoes the beam-induced motion observed in single-particle cryoEM. As with motion correction for cryoEM imaging experiments, accounting for BIR-induced errors during data processing could improve the accuracy of MicroED data.

Vlahakis, Niko (ORCID:0000000250920265)↗

Online and Offline Data Quality Monitoring for the Mu2e Calorimeter

This thesis presents the design, implementation, and validation of a calorimeter Data Quality Monitoring (DQM) toolchain for the Mu2e experiment at Fermilab. Mu2e searches for charged lepton flavor violation via coherent muon-to-electron conversion in the field of an aluminum nucleus, $\mu^- Al \rightarrow e^-Al$, a process whose observation would constitute clear evidence of physics beyond the Standard Model. Achieving target sensitivity requires stringent control of detector performance and data integrity during acquisition, as subtle issues in readout configuration, data formatting, or electronics behavior can compromise reconstruction and bias downstream analyzes. To address these challenges, this work develops a multi-layer DQM approach spanning both raw data validation and reconstructed digi-level diagnostics. At the low level, a fragment analysis component performs word- and bit-field decoding of calorimeter readout blocks, enabling sanity checks of the expected structure and producing detailed error and integrity statistics useful for commissioning and troubleshooting. At the digi level, the CaloDigiDQM analyzer is implemented within the art framework and transforms each CaloDigiCollection into a structured hierarchy of ROOT histograms designed for fast drill-down diagnostics. The module generates coherent monitoring views at global, disk, board, and channel granularity, including occupancy, waveform-derived features (baseline, RMS, peak amplitude and position), and left-right sensor consistency metrics. Detector-aware channel-to-electronics mapping is performed through the conditions system (CaloDAQMap), ensuring that diagnostics remain aligned with hardware identifiers used in operations. For end-to-end testing without reliance on live DAQ data, a synthetic CaloDigi producer is developed to generate realistic waveforms with controlled noise and pulse shapes. The resulting system supports both offline ROOT-file production and online operation, including optional histogram streaming through otsdaq via ots::HistoSender. This toolchain provides a practical and scalable foundation for calorimeter commissioning and stable data collection, enabling early detection of anomalies and reducing operational risk for Mu2e.

Vakulenko, Mark [Drew U.] (ORCID:0009000276197818)↗

NuGraph2: A Graph Neural Network for Neutrino Event Reconstruction

Neutrino experiments are set to probe some of the most important open questions in physics, from CP violation and the nature of dark matter. The technology of choice for many of these experiments is the liquid argon time projection chamber (LArTPC). In current LArTPC experiments, reconstruction performance often represents a limiting factor for the sensitivity. New developments are therefore needed to unlock the full potential of LArTPC experiments. NuGraph2 is a state of the art Graph Neural Network for reconstruction of data in LArTPC experiments [https://arxiv.org/abs/2403.11872]. NuGraph2 utilizes a heterogeneous graph structure, with separate subgraphs of 2D nodes (hits in each plane) connected across planes via 3D nodes (space points). The model provides a consistent description of the neutrino interaction across all planes. NuGraph2 is a multi-purpose network, with a common message-passing attention engine connected to multiple decoders with different classification or regression tasks. These include the classification of detector hits according to the particle type that produced them (semantic segmentation) and the separation of hits from the neutrino interaction from hits due to noise or cosmic-ray background. Additional decoders are being developed, performing tasks such as the regression of the neutrino interaction vertex position. Performance results will be presented based on publicly available samples from MicroBooNE. These include both physics performance metrics, achieving 95% accuracy for semantic segmentation and 98% classification of neutrino hits, as well as computational metrics for training and for inference on CPU or GPU. The status of the NuGraph integration in the LArSoft software framework will be presented, as well as initial studies about model interpretability and injection of domain knowledge.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Applications of a single-molecule detection in early disease diagnosis and enzymatic reaction study

Various single-molecule techniques were utilized for ultra-sensitive early diagnosis of viral DNA and antigen and basic mechanism study of enzymatic reactions. DNA of human papilloma virus (HPV) served as the screening target in a flow system. Alexa Fluor 532 (AF532) labeled single-stranded DNA probes were hybridized to the target HPV-16 DNA in solution. The individual hybridized molecules were imaged with an intensified charge-coupled device (ICCD) in two ways. In the single-color mode, target molecules were detected via fluorescence from hybridized probes only. This system could detect HPV-16 DNA in the presence of human genomic DNA down to 0.7 copy/cell and had a linear dynamic range of over 6 orders of magnitude. In the dual-color mode, fluorescence resonance energy transfer (FRET) was employed to achieve zero false-positive count. We also showed that DNA extracts from Pap test specimens did not interfere with the system. A surface-based method was used to improve the throughput of the flow system. HPV-16 DNA was hybridized to probes on a glass surface and detected with a total internal reflection fluorescence (TIRF) microscope. In the single-probe mode, the whole genome and target DNA were fluorescently labeled before hybridization, and the detection limit is similar to the flow system. In the dual-probe mode, a second probe was introduced. The linear dynamic range covers 1.44-7000 copies/cell, which is typical of early infection to near-cancer stages. The dual-probe method was tested with a crudely prepared sample. Even with reduced hybridization efficiency caused by the interference of cellular materials, we were still able to differentiate infected cells from healthy cells. Detection and quantification of viral antigen with a novel single-molecule immunosorbent assay (SMISA) was achieved. Antigen from human immunodeficiency virus type 1(HIV-1) was chosen to be the target in this study. The target was sandwiched between a monoclonal capture antibody and a polyclonal detector antibody. The capture antibody was covalently immobilized on modified glass slides. The detector antibody was conjugated with AF532 labeled secondary antibody prior to being used as probe for the antigen. Imaging was performed with a TIRF system. This technique is demonstrated for detecting HIV-1 p24 antigen down to 0.1 pg/mL with a dynamic range of over 4 orders of magnitude. A Langmuir isotherm fit the molecule count dependence on the target concentration. The results also showed that neither sensitivity nor dynamic range was affected by the biological matrix. SMISA is therefore a promising approach for the early diagnosis of virus-induced diseases. Single-molecule enzymatic kinetics and enantioselectivity were monitored in real time by using TIRF microscopy. AF532 labeled poly-L-lysine (PLL) or poly-D-lysine (PDL) was covalently immobilized on a dithiobis (succinimidyl undecanoate) self-assembled monolayer (DSU SAM). Chain shortening due to enzymatic hydrolysis resulted in the reduction of the individual fluorescence intensities. A broad distribution was obtained when 100 single-molecule half-lives were analyzed. However, the detailed hydrolysis process involved also a long-lived component and an induction period that varied significantly among molecules. Charge and steric heterogeneity at the surface are responsible for these features.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Time-dependent and time-integrated angular analysis of B{yields}{phi}K{sub S}{sup 0}{pi}{sup 0} and {phi}K{sup {+-}}{pi}{sup {+-}}

We perform a time-dependent and time-integrated angular analysis of the decays B{sup 0}{yields}{phi}K*(892){sup 0}, {phi}K{sub 2}*(1430){sup 0}, and {phi}(K{pi}){sub 0}*{sup 0} with the final sample of about 465x10{sup 6} BB pairs recorded with the BABAR detector. Twenty-four parameters are investigated, including the branching fractions, CP-violation parameters, and parameters sensitive to final-state interactions. We use the dependence on the K{pi} invariant mass of the interference between the scalar and vector or tensor components to resolve discrete ambiguities of the strong and weak phases. We use the time evolution of the B{yields}{phi}K{sub S}{sup 0}{pi}{sup 0} channel to extract the CP-violation phase difference {delta}{phi}{sub 00}=0.28{+-}0.42{+-}0.04 between the B and B decay amplitudes. When the B{yields}{phi}K{sup {+-}}{pi}{sup {+-}} channel is included, the fractions of longitudinal polarization f{sub L} of the vector-vector and vector-tensor decay modes are measured to be 0.494{+-}0.034{+-}0.013 and 0.901{sub -0.058}{sup +0.046}{+-}0.037, respectively. This polarization pattern requires the presence of a positive-helicity amplitude in the vector-vector decay from a currently unknown source.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Epid Dosimetry

Electronic portal imaging devices (EPIDs) were introduced originally for patient position verification. The idea of using EPIDs for dosimetry was realised in the 1980s. Little was published on the topic until the mid 1990's, when the interest in EPIDs for dosimetry increased rapidly and continues to grow. The increasing research on EPID dosimetry coincided with the introduction of intensity modulated radiation therapy (IMRT). EPIDs are well suited to IMRT dosimetry because they are high resolution, two-dimensional (2D) digital detectors. They are also pre-existing on almost all modern linear accelerators. They generally show a linear response to increasing dose. Different types of EPIDs have been clinically implemented, and these have been described in several review papers. The current generation of commercially available EPIDs are indirect detection active matrix flat panel imagers, also known as amorphous silicon (a-Si) EPIDs. Disadvantages of a-Si EPIDs for dosimetry include non-water equivalent construction materials, and the energy sensitivity and optical scatter of the phosphor scintillators used to create optical signal from the megavoltage beam. This report discusses current knowledge regarding a-Si EPIDs for dosimetry.

61 RADIATION PROTECTION AND DOSIMETRY↗