Search NASA⌕ Search

SEARCH · Search NASA

Results for “Positioning Resolution”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 721 records · Page 40

Appending High-Resolution Elevation Data to GPS Speed Traces for Vehicle Energy Modeling and Simulation

Accurate and reliable global positioning system (GPS)-based vehicle use data are highly valuable for many transportation, analysis, and automotive considerations. Model-based design, real-world fuel economy analysis, and the growing field of autonomous and connected technologies (including predictive powertrain control and self-driving cars) all have a vested interest in high-fidelity estimation of powertrain loads and vehicle usage profiles. Unfortunately, road grade can be a difficult property to extract from GPS data with consistency. In this report, we present a methodology for appending high-resolution elevation data to GPS speed traces via a static digital elevation model. Anomalous data points in the digital elevation model are addressed during a filtration/smoothing routine, resulting in an elevation profile that can be used to calculate road grade. This process is evaluated against a large, commercially available height/slope dataset from the Navteq/Nokia/HERE Advanced Driver Assistance Systems product. Results will show good agreement with the Advanced Driver Assistance Systems data in the ability to estimate road grade between any two consecutive points in the contiguous United States.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Joint X-ray and neutron refinement with phenix.refine

The implementation of crystallographic structure-refinement procedures that include both X-ray and neutron data (separate or jointly) in the PHENIX system is described. Approximately 85% of the structures deposited in the Protein Data Bank have been solved using X-ray crystallography, making it the leading method for three-dimensional structure determination of macromolecules. One of the limitations of the method is that the typical data quality (resolution) does not allow the direct determination of H-atom positions. Most hydrogen positions can be inferred from the positions of other atoms and therefore can be readily included into the structure model as a priori knowledge. However, this may not be the case in biologically active sites of macromolecules, where the presence and position of hydrogen is crucial to the enzymatic mechanism. This makes the application of neutron crystallography in biology particularly important, as H atoms can be clearly located in experimental neutron scattering density maps. Without exception, when a neutron structure is determined the corresponding X-ray structure is also known, making it possible to derive the complete structure using both data sets. Here, the implementation of crystallographic structure-refinement procedures that include both X-ray and neutron data (separate or jointly) in the PHENIX system is described.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Crystallographic features related to a van der Waals coupling in the layered chalcogenide FePS{sub 3}

We investigated the crystallographic structure of FePS{sub 3} with a layered structure using transmission electron microscopy and powder X-ray diffraction. We found that FePS{sub 3} forms a rotational twin structure with the common axis along the c*-axis. The high-resolution transmission electron microscopy images revealed that the twin boundaries were positioned at the van der Waals gaps between the layers. The narrow bands of dark contrast were observed in the bright-field transmission electron microscopy images below the antiferromagnetic transition temperature, T{sub N} ≈ 120 K. Low-temperature X-ray diffraction showed a lattice distortion; the a- and b-axes shortened and lengthened, respectively, as the temperature decreased below T{sub N.} We propose that the narrow bands of dark contrast observed in the bright-field transmission electron microscopy images are caused by the directional lattice distortion with respect to each micro-twin variant in the antiferromagnetic phase.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Design and Performance Testing of a Linear Array of Position-Sensitive Virtual Frisch-Grid CdZnTe Detectors for Uranium Enrichment Measurements

Arrays of position-sensitive virtual Frisch-grid CdZnTe (CZT) detectors with enhanced energy resolution have been proposed for spectroscopy and imaging of gamma-ray sources in different applications. The flexibility of the array design, which can employ CZT crystals with thicknesses up to several centimeters in the direction of electron drift, allows for integration into different kinds of field-portable instruments. These can include small hand-held devices, compact gamma cameras and large field-of-view imaging systems. In this work, we present results for a small linear array of such detectors optimized for the low-energy region, 50-400 keV gamma-rays, which is principally intended for incorporation into hand-held instruments. There are many potential application areas for such instruments, including uranium enrichment measurements, storage monitoring, dosimetry and other safeguards-related tasks that can benefit from compactness and isotope-identification capability. The array described here provides a relatively large area with a minimum number of readout channels, which potentially allows the developers to avoid using an ASIC-based electronic readout by substituting it with hybrid preamplifiers followed by digitizers. The array prototype consists of six (5x5.7x25 mm3) CZT detectors positioned in a line facing the source to achieve a maximum exposure area (~10 cm2). Each detector is furnished with 5 mm-wide charge-sensing pads placed near the anode. The pad signals are converted into X-Y coordinates for each interaction event, which are combined with the cathode signals (for determining the Z coordinates) to give 3D positional information for all interaction points. This information is used to correct the response non-uniformity caused by material inhomogeneity, which therefore allows the usage of standard-grade (unselected) CZT crystals, while achieving high-resolution spectroscopic performance for the instrument. In this presentation we describe the design of the array, the results from detailed laboratory tests, and preliminary results from measurements taken during a field test.

36 MATERIALS SCIENCE↗

A fast and reliable method for daily quality assurance in spot scanning proton therapy with a compact and inexpensive phantom

In a radiotherapy center, daily quality assurance (QA) measurements are performed to ensure that the equipment can be safely used for patient treatment on that day. In a pencil beam scanning (PBS) proton therapy center, spot positioning, spot size, range, and dose output are usually verified every day before treatments. We designed, built, and tested a new, reliable, sensitive, and inexpensive phantom, coupled with an array of ionization chambers, for daily QA that reduces the execution times while preserving the reliability of the test. The phantom is provided with 2 pairs of wedges to sample the Bragg peak at different depths to have a transposition on the transverse plane of the depth dose. Three “boxes” are used to check spot positioning and delivered dose. The box thickness helps spread the single spot and to fit a Gaussian profile on a low resolution detector. We tested whether our new QA solution could detect errors larger than our action levels: 1 mm in spot positioning, 2 mm in range, and 10% in spot size. Execution time was also investigated. Our method is able to correctly detect 98% of spots that are actually in tolerance for spot positioning and 99% of spots out of 1 mm tolerance. All range variations greater than the threshold (2 mm) were correctly detected. The analysis performed over 1 month showed a very good repeatability of spot characteristics. The time taken to perform the daily quality assurance is 20 minutes, a half of the execution time of the former multidevice procedure. This “in-house build” phantom substitutes 2 very expensive detectors (a multilayer ionization chamber [MLIC] and a strip chamber, reducing by 5 times the cost of the equipment. We designed, built, and validated a phantom that allows for accurate, sensitive, fast, and inexpensive daily QA procedures in proton therapy with PBS.

61 RADIATION PROTECTION AND DOSIMETRY↗

Poster — Thur Eve — 07: Simultaneous reconstruction of both true and scattered coincidences using a Generalized Scatter reconstruction algorithm in PET

Introduction: Scattered coincidences in PET are generally taken as noise, which reduces image contrast and compromises quantification. We have developed a method, with promising results, to reconstruct activity distribution from scattered PET events instead of simply correcting for them. The implementation of this method on clinical PET scanners is however limited by the currently available detector energy resolution. With low energy resolution we lose the ability to distinguish scattered coincidences from true events based on the measured photon energy. In addition the two circular arcs used to confine the source position for a scattered event cannot be accurately defined. Method: This paper presents a modification to this approach which accounts for limited energy resolution. A measured event is split into a true and a scattered component each with different probabilities based on the position of the pair of photon energies in the energy spectrum. For the scattered component, we model the photon energy with a Gaussian distribution and the upper and lower energy limits can be estimated and used to define inner and outer circular arcs to confine the source position. The true and scattered components for each measured event were reconstructed using our Generalized Scatter reconstruction algorithm. Results and Conclusion: The results show that the contrast and noise properties were improved by 6–9% and 2–4% respectively. This demonstrates that the performance of the algorithm is less sensitive to the energy resolution and that incorporating scattered photons into reconstruction brings more benefits than simply rejecting them.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Terrestrial laser scanning data (Levels 0 and 1) for Pasoh, Malaysia, Sep 2024

This data package contains data from terrestrial laser scanning (TLS) at the Pasoh Forest Reserve, Malaysia. The Pasoh Forest Reserve is a facility of the Forest Research Institute Malaysia, and contains evergreen lowland dipterocarp forest. The Next-Generation Ecosystem Experiments Tropics (NGEE-Tropics) study areas at Pasoh were established to study how different species respond to climatic variation and soil water availability. Two study areas were chosen representing different topography and species. The TLS data archived here were collected to provide detailed, three-dimensional information about forest structure. Specifically, data were collected to allow tree-level characterization of woody structure and leaf area for 12 focal trees with FloraPulse and sap flux sensors, facilitating estimation of woody biomass and leaf area to allow upscaling of water content and transpiration data to the tree-level. Scan positions were not selected to provide consistent data for non-focal trees with the study areas. This data package contains the following data: - High-level files document further details of the campaign and data package: 1_CampaignSummary.csv provides details about the campaign and study site, 2_ScanAreasDetail.csv provides details about each separate scan area (groups of scans post-processed into a single point cloud), 3_TerrestrialLidarSensor.csv provides further technical details about the Riegl VZ-400i TLS sensor, TLS_CSV_dd.csv is a CSV Data Dictionary providing information about the fields in CSV files following the ESS-DIVE CSV File Formatting Guidelines Reporting Format, TLS_flmd.csv is a File Level Metadata file providing information about each file in the data package following the ESS-DIVE File Level Metadata Reporting Format, and README.txt is a text file describing the overall project and file structure. - Level 0 data are the raw data (.PROJ folders) as recorded by the Riegl VZ-400i TLS instrument before scan co-registration and post-processing with the Riegl's proprietary RiSCAN PRO software, which requires a license. - Level 1 data contain post-processed, co-registered data from each scan area. The "PointClouds" folder for each scan area contains a .las file with 1 cm resolution point cloud data exported from RiSCAN PRO. These are the main files likely to be of interest to most users and can be further processed with any software capable of manipulating .las files (e.g. Python, R CloudCompare). The "Project Information" folder contains log files from post-processing in RiSCAN PRO that may be of interest to users who want to see detailed records of post-processing, including all PDF reports generated by RiSCAN PRO. The "ScanPositions" folder contains information about the final position of all TLS scans, after post-processing, in multiple formats. The file ScanPositions_*.csv provides final geo-referenced scan positions, and the file SOP_backup_*.csv can be used in RiSCAN PRO to restore the co-registered scan positions if users wish to re-process raw data (Level 0 .PROJ folders) with RiSCAN PRO software (e.g., subsample to a different resolution, exclude a certain scan position, or apply different filters on reflectance or deviation values) without redoing time-consuming co-registration steps.

54 ENVIRONMENTAL SCIENCES↗

Multiwavelength observations of the candidate disintegrating sub-Mercury KIC 12557548B , ,

We present multiwavelength photometry, high angular resolution imaging, and radial velocities of the unique and confounding disintegrating low-mass planet candidate KIC 12557548b. Our high angular resolution imaging, which includes space-based Hubble Space Telescope Wide Field Camera 3 (HST/WFC3) observations in the optical (∼0.53 μm and ∼0.77 μm), and ground-based Keck/NIRC2 observations in K' band (∼2.12 μm), allow us to rule out background and foreground candidates at angular separations greater than 0.''2 that are bright enough to be responsible for the transits we associate with KIC 12557548. Our radial velocity limit from Keck/HIRES allows us to rule out bound, low-mass stellar companions (∼0.2 M {sub ☉}) to KIC 12557548 on orbits less than 10 yr, as well as placing an upper limit on the mass of the candidate planet of 1.2 Jupiter masses; therefore, the combination of our radial velocities, high angular resolution imaging, and photometry are able to rule out most false positive interpretations of the transits. Our precise multiwavelength photometry includes two simultaneous detections of the transit of KIC 12557548b using Canada-France-Hawaii Telescope/Wide-field InfraRed Camera (CFHT/WIRCam) at 2.15 μm and the Kepler space telescope at 0.6 μm, as well as simultaneous null-detections of the transit by Kepler and HST/WFC3 at 1.4 μm. Our simultaneous HST/WFC3 and Kepler null-detections provide no evidence for radically different transit depths at these wavelengths. Our simultaneous CFHT/WIRCam detections in the near-infrared and with Kepler in the optical reveal very similar transit depths (the average ratio of the transit depths at ∼2.15 μm compared with ∼0.6 μm is: 1.02 ± 0.20). This suggests that if the transits we observe are due to scattering from single-size particles streaming from the planet in a comet-like tail, then the particles must be ∼0.5 μm in radius or larger, which would favor that KIC 12557548b is a sub-Mercury rather than super-Mercury mass planet.

79 ASTRONOMY AND ASTROPHYSICS↗

Algebraic discrete quantum harmonic oscillator with dynamic resolution scaling

We develop an algebraic formulation for the discrete quantum harmonic oscillator (DQHO) from the Hamiltonian for two, coupled QHOs and provide a physical picture for the Kravchuk function eigenstates of the oscillator. The familiar $\mathfrak{su}(2)$ structure of the coupled QHO Hamiltonian divides its spectrum into sets corresponding to the DQHO at different resolutions. In addition to energy ladder operators, the formulation allows for the introduction of resolution ladder operators connecting all DQHOs with different resolutions, thus enabling the dynamic scaling of the resolution of finite degree-of-freedom quantum simulations. The coherent state of the DQHO is constructed, and its expected position is proven to oscillate as a classical harmonic oscillator. The DQHO coherent state recovers that of the quantum harmonic oscillator at large resolution.

97 MATHEMATICS AND COMPUTING↗

Performance of position-sensitive resistive silicon detectors in the Forward Array Using Silicon Technology (FAUST)

The silicon telescopes of the Forward Array Using Silicon Technology (FAUST) have been recently upgraded with silicon detectors which use resistive charge-splitting to measure the position of charged particles. This is in addition to the measurement of the total energy that these charged particles deposit in the detector. The upgrade results in increased angular resolution with a much smaller number of signals than silicon strip detectors with similar resolution. Here, a novel method of calibration has been used to demonstrate the efficacy of these position-sensitive detectors, and the detectors have been used in a commissioning experiment.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Transfer Reactions and the Structure of Neutron-rich Nuclei

The study of transfer reactions in inverse kinematics is a major focus of existing and future radioactive-ion-beam facilities. One of the obstacles in such measurements is poor Q-value resolution, often several hundred keV, which can prevent the extraction of useful information. At Argonne National Laboratory, it has recently been demonstrated that good Q-value resolution can be achieved by transporting the outgoing ions through a high-field solenoid, measuring their position as a function of energy. Furthermore, this provides several advantages over conventional Si arrays, such as large acceptance, good particle identification, and most importantly a Q-value resolution of better than 100 keV in most cases, including reactions with moderately heavy beams. In this paper, the concept of the solenoidal spectrometer, called HELIOS, will be discussed along with highlights of recent results.

43 PARTICLE ACCELERATORS↗

Picometer-Precision Atomic Position Tracking through Electron Microscopy

The modern aberration-corrected scanning electron microscopes have successfully achieved direct visualization of atomic columns with sub-angstrom resolution. With this significant progress, advanced image quantification and analysis is still at its early stages. In this work, we present the complete pathway for the metrology of atomic resolution STEM images. This includes: 1) tips for acquiring high-quality STEM images; 2) denoising and drift-correction for enhancing measurement accuracy; 3) obtaining initial atom positions; 4) indexing the atoms based on unit cell vectors; 4) quantifying the atom column positions with either 2D-gaussian single peak fitting or 5) multi-peak fitting routines for slightly overlapping atomic columns; 6) quantification of lattice distortion/strain within the crystal structures or at the defects/interfaces where the lattice periodicity is disrupted, and 7) some common methods to visualize and present the analysis. Furthermore, a simple self-developed free MATLAB app (EASY-STEM) with a graphical user interface (GUI) will be introduced that can help with the analysis of STEM images without the need for writing dedicated analysis code or software. The advanced data analysis methods presented here can be applied for the local quantification of defect relaxations, local structural distortions, local phase transformations, and non-centrosymmetry in a wide range of materials.

47 OTHER INSTRUMENTATION↗

Design and Characterization of an Extremely-Sensitive, Large-Volume Gamma-Ray Spectrometer for Environmental Samples

A large volume gamma spectrometer was designed and constructed to analyze foodstuffs and environmental samples having low radionuclide concentrations. This system uses eight 11-cm × 42.5-cm × 5.5-cm NaI(Tl) detectors, chosen due to their relatively high sensitivity and availability and arranged in an octagonal configuration. The sensitive volume of the system is ~28 cm in diameter and ~42 cm deep. Shielding consists of an 86-cm × 86-cm square, 64-cm-tall lead brick enclosure with 18-cm-thick lead walls lined by 0.3-cm-thick copper plates. An aluminum top was machined to suspend the detectors within this shield. The shielding reduces background counts by 72% at 100 keV and 42% at 1,000 keV. The positional variability in sensitivity of the well was determined by both simulation and experiment. A 2.1-L volume of nearly uniform sensitivity, varying less than 10%, exists in the well's center. Energy resolutions of 14.6% and 7.8% were measured for 241 Am and 137 Cs, respectively. Energy resolution shows a 0.2% variation for both 241 Am and 137 Cs as a function of position within all regions of the well’s central sensitive volume. Dead time was also determined to be less than 35% for all sources measured in the system, the largest of which had an activity of 1,760 kBq. Simulated results for various source geometries show higher counts for smaller samples, especially at lower energies due to less attenuation of low energy photons. In conclusion, minimum detectable activities were determined for all source energies used, less than 5.1 Bq kg -1 for reasonable background and sample counting times.

47 OTHER INSTRUMENTATION↗

Coupling Gammasphere and ORRUBA

The coincident detection of particles and gamma rays allows the study of the structure of exotic nuclei via inverse kinematics reactions using radioactive ion beams and thick targets. We report on the status of the project to couple the highresolution charged-particle detector ORRUBA to Gammasphere, a high-efficiency, high-resolution gamma ray detector.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Gantryless Associated-Particle Neutron Radiography

The present work reports on the development of techniques for in-field fast-neutron radiography measurements using the associated-particle imaging (API) method. The API method employs alpha-neutron coincidences from the d+t→α+n reaction to enable fast neutron transmission imaging with excellent contrast using a wide cone beam. However, for field radiography applications, the API method is burdened by the need for the relative positions of the source and detector to be known. Fortunately, these relative positions can be inferred from transmission data. The inferred positions also enable accurate stitching of multiple images into a composite image even when using a low-resolution detector panel and acquiring images having few overlapping pixels. The developed techniques address analysis of measurements where (1) the source and detector panel are separately hand positioned rather than held in registration by a gantry, (2) multiple detector panel positions within the “coincident cone” of tagged neutrons are required to piece together an image of an item of interest, and (3) normalization measurements that have identical source-detector positioning but without the inspected object are not possible. The present work will describe the system calibrations (including timing calibrations and neutron direction calibrations) necessary for subsequent analyses, the method of locating the detector in the coincident cone of neutrons with millimeter precision using the timing and directions of coincident neutrons, the method of calculating a normalization image for a given detector panel position, and the method used to project multiple images into a common image.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Examining Cloud Feedback Components in the Simple Cloud-Resolving E3SM Atmosphere Model (SCREAM)

Cloud feedback remains the main source of uncertainty in climate sensitivity estimated by global climate models (GCMs), largely because subgrid cloud responses are parameterized in GCMs due to their coarse resolution. Here, this study examines cloud feedback in the global 3.25-km Simple Cloud-Resolving Energy Exascale Earth System Model (E3SM) Atmosphere Model (SCREAM 3 km) through a pair of 1-yr atmosphere-only simulations with control and +4-K sea surface temperature perturbations. SCREAM 3 km produces a positive cloud feedback that falls within but at the upper end of the range of Coupled Model Intercomparison Project phase 5 (CMIP5) and CMIP phase 6 (CMIP6) models and expert judgment. The positive cloud feedback arises from positive contributions from both high- and low-level clouds, with increases in high-cloud altitude and decreases in low-cloud amount and optical depth playing key roles. The stronger-than-CMIP-average feedback is mainly attributable to the high-cloud altitude feedback, owing to cloud tops rising nearly isothermally in SCREAM 3 km. The positive low-cloud amount feedback is weaker in SCREAM than in GCMs because estimated inversion strength (EIS) increases more dramatically with warming. A coarser 12-km resolution version of SCREAM exhibits a weaker positive cloud feedback than SCREAM 3 km, mainly because its low-cloud-radiative flux is more sensitive to EIS, leading to a stronger negative low-cloud amount feedback. With this process-level assessment of cloud feedback, this study reveals where SCREAM aligns with and diverges from conventional GCMs and expert assessment, providing insights to inform further model improvement and future expert assessment.

Cloud radiative effects↗

Complex Electronic Structure of Rare Earth Activators in Scintillators

To aid and further the understanding of the microscopic mechanisms behind the scintillator nonproportionality that leads to degradation of the attainable energy resolution, we have developed theoretical and experimental algorithms and procedures to determine the position of the 4f energy levels of rare earth dopants relative to the host band edge states.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Contemporary Tectonic Motion of the Eastern Snake River Plain: A Campaign Global Positioning System Study

A comparison of precision campaign GPS data from 1995 and 2004 from ten benchmarks on the eastern Snake River Plain (eSRP) has revealed that the province moved 2.8 ± 0.3 mm/yr to the SW (232.4 ± 6.3°) relative to a fixed North American reference frame. The benchmarks had no measurable displacement relative to one another at the resolution of the GPS during the nine-year study, evidence that the province moves as a rigid, non-extending block. This scenario is supported by the aseismic nature of the province and the lack of measurable horizontal stress in boreholes. However, an additional small component of intra-plain extension must also be invoked to account for the observed NW-trending volcanic rift zones that transect the eSRP. We suggest that intra-plain extension is too slow (<1 mm/yr) to measure using our campaign GPS methods, but may be sufficient over millennial time scales to accommodate rift zone formation. Slower velocities measured on three benchmarks within the neighboring Basin and Range ‘seismic parabola’ are consistent with this region serving as a zone of detachment between the North American craton and the faster-moving eSRP.

54 ENVIRONMENTAL SCIENCES↗