Search NASA⌕ Search

SEARCH · Search NASA

Results for “Positioning System”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 721 records · Page 40

Linear servomotor probe drive system with real-time self-adaptive position control for the Alcator C-Mod tokamak

A new servomotor drive system has been developed for the horizontal reciprocating probe on the Alcator C-Mod tokamak. Real-time measurements of plasma temperature and density—through use of a mirror Langmuir probe bias system—combined with a commercial linear servomotor and controller enables self-adaptive position control. Probe surface temperature and its rate of change are computed in real time and used to control probe insertion depth. It is found that a universal trigger threshold can be defined in terms of these two parameters; if the probe is triggered to retract when crossing the trigger threshold, it will reach the same ultimate surface temperature, independent of velocity, acceleration, or scrape-off layer heat flux scale length. In addition to controlling the probe motion, the controller is used to monitor and control all aspects of the integrated probe drive system.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Linear servomotor probe drive system with real-time self-adaptive position control for the Alcator C-Mod tokamak

A new servomotor drive system has been developed for the horizontal reciprocating probe on the Alcator C-Mod tokamak. Real-time measurements of plasma temperature and density—through use of a mirror Langmuir probe bias system—combined with a commercial linear servomotor and controller enable self-adaptive position control. Probe surface temperature and its rate of change are computed in real time and used to control probe insertion depth. It is found that a universal trigger threshold can be defined in terms of these two parameters; if the probe is triggered to retract when crossing the trigger threshold, it will reach the same ultimate surface temperature, independent of velocity, acceleration, or scrape-off layer heat flux scale length. Finally, in addition to controlling the probe motion, the controller is used to monitor and control all aspects of the integrated probe drive system.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Risk of Positive Sentinel Lymph Node After Neoadjuvant Systemic Therapy in Clinically Node-Negative Breast Cancer: Implications for Postmastectomy Radiation Therapy and Immediate Breast Reconstruction

Background: Residual axillary lymph node involvement after neoadjuvant systemic therapy (NST) is the determining factor for postmastectomy radiation therapy (PMRT). Preoperative identification of patients needing PMRT is essential to enable shared decision-making when choosing the optimal timing of breast reconstruction. We determined the risk of positive sentinel lymph node (SLN) after NST in clinically node-negative (cN0) breast cancer. Methods: All cT1-3N0 patients treated with NST followed by mastectomy and SLNB between 2010 and 2016 were identified from the Netherlands Cancer Registry. Rate of positive SLN for different breast cancer subtypes was determined. Logistic regression analysis was performed to determine correlated clinicopathological variables with positive SLN. Results: In total 788 patients were included, of whom 25.0% (197/788) had positive SLN. cT1-3N0 ER+HER2+, cT1-3N0 ER−HER2+ , and cT1-2N0 triple-negative patients had the lowest rate of positive SLN: 7.2–11.5%, 0–6.3%, and 2.9–6.2%, respectively. cT1-3N0 ER+HER2− and cT3N0 triple-negative patients had the highest rate of positive SLN: 23.8–41.7% and 30.4%, respectively. Multivariable regression analysis showed that cT2 (odds ratio [OR] 1.93; 95% confidence interval [CI] 1.01–3.96), cT3 (OR 2.56; 95% CI 1.30–5.38), grade 3 (OR 0.44; 95% CI 0.21–0.91), and ER+HER2− subtype (OR 3.94; 95% CI 1.77–8.74) were correlated with positive SLN. Conclusions: In cT1-3N0 ER+HER2+, cT1-3N0 ER−HER2+, and cT1-2N0 triple-negative patients treated with NST, immediate reconstruction can be considered an acceptable option due to low risk of positive SLN. In cT1-3N0 ER+HER2− and cT3N0 triple-negative patients treated with NST, risks and benefits of immediate reconstruction should be discussed with patients due to the relatively high risk of positive SLN.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Test facility for fission chamber assemblies - 239

The Institution -Project Center ITER- with participation of the National Research Nuclear University MEPhI are developing the neutron diagnostics -Divertor Neutron Flux Monitor- (DNFM) for the International Thermonuclear Experimental Reactor (ITER). This diagnostics shall ensure measurement of the total neutron yield and ITER fusion power. Assemblies of fission chambers (FC) with different fissile materials and sensitivities are planned to be used for the neutron flux measurement. Study of fission chambers characteristics and acceptance testing of the diagnostic system will be carried out at the testing facility of the neutronic laboratory of the 'TRINITI' Institute. The facility includes: compact powerful neutron generator with the power, control and monitoring system; remote handling system for FCs positioning and movement; novel three channels data acquisition and processing system. Each acquisition channel contains some measuring circuits with signal processing. This set of circuits provides neutron flux measurement in the range of at least 10 decades for each single FC. Data acquisition and processing system features are: signal digitizing with sample rate up to 125 MHz; real time data processing with computation and data update cycle from 0.1 ms. This paper examines the structure, composition and specification of the test facility. Application software, hardware solutions and the results of fission chambers prototypes tests are discussed. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Numerical studies of entangled positive-partial-transpose states in composite quantum systems

We report here on the results of numerical searches for PPT states in a series of bipartite quantum systems of low dimensions. PPT states are represented by density matrices that remain positive semidefinite under partial transposition with respect to one of the subsystems, and our searches are for such states with specified ranks for the density matrix and its partial transpose. For a series of different ranks extremal PPT states and nonextremal entangled PPT states have been found. The results are listed in tables and charted in diagrams. Comparison of the results for systems of different dimensions reveals several regularities. We discuss lower and upper bounds on the ranks of extremal PPT states.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

The existence and concentration of positive solutions for a nonlinear Schrödinger-Poisson system with critical growth

We consider the Schrödinger-Poisson system: −ε{sup 2}Δu + V(x)u + ϕ(x)u = f(u),−Δϕ = u{sup 2} in R{sup 3}, where the nonlinear term f is of critical growth. In this paper, we construct a solution (u{sub ε}, ϕ{sub ε}) of the above elliptic system, which concentrates at an isolated component of positive locally minimum points of V as ε → 0 under certain conditions on f. In particular, the monotonicity of (f(s))/(s{sup 3}) and the so-called Ambrosetti-Rabinowitz condition are not required.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Machine Learning Enabled Position Detection for 6.78 MHz UAV Wireless Power Transfer System

This paper presents a novel supervised machine learning (SML) approach for accurate position detection of the receiver coil in wireless power transfer (WPT) systems using only secondary-side electrical measurements, with applications in autonomous unmanned aerial vehicle (UAV) charging. The proposed method trains a supervised learning model to map measured secondary-side voltage and current features to the receiver’s spatial position with high precision. This enables an autonomous UAV to determine its location relative to the primary coil center, the optimal position for maximizing wireless charging efficiency. The sensing method is fully integrated into a standard WPT system, utilizing the same primary and secondary coils for both power transfer and position detection, thereby eliminating additional sensing hardware. The use of a 6.78 MHz operating frequency enhances positional sensitivity, as high-frequency near-field electromagnetic fields respond strongly to small spatial variations. Experimental validation is performed on a 30 W scaled prototype featuring a 210 mm × 140 mm primary coil, a 50 mm × 80 mm receiver coil, and a 15 mm air gap. Results demonstrate reliable position estimation and a strong correlation between predicted position and optimal coil alignment. This integrated framework unifying position detection and wireless charging offers a promising foundation for future autonomous electric vertical takeoff and landing (eVTOL) systems, enabling compact, hardware-efficient, and high-accuracy charging solutions.

Colak, Kerim [New York University]↗

Benefits of digitalizing and employing simulation to increase plant system performance and ensure compliance with technical specifications - 109

The essential services water system in a BWR nuclear power plant was affected by corrosion, soiling and blockages due to ageing. Those episodes affected safety margins hindering the Technical Specifications compliance during periodic system testing. Tecnatom designed, implemented and tested a design modification for the on-line monitoring of this system by integrating it in the existing Digital Control System (DCS). Key system parameters were acquired in real time to be displayed in the Human System Interface, used in performing calculations and stored their historical evolution. The objective was to optimize monitoring and surveillance of the essential service water system. Furthermore, Tecnatom developed an engineering simulator ('What if' simulator) consisting of a hydraulic model of the system. This simulator takes as inputs each heat exchanger performance parameters from the plant DCS, allows the user to change the essential services water system configuration (valves position, UHS level...) and calculates theoretical process values predicting the system real behavior. In a second stage, more system instruments were wired to the DCS for Technical Specifications compliance automatic surveillance regarding opening and closing times of system valves. Operating experience shows important benefits after the digitalization. It enhances on-line information of system operation and automates calculation of load loss factor of each heat exchanger. It eases the evaluation of blockages and soiling in the system allowing optimization of cleaning proceedings. System Surveillance Requirements and Test Requirements reports have been automated optimizing the operation workload. The simulator use enables to identify optimal system configuration increasing safety margins of the system and ensuring Technical Specifications fulfillment. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Improved laser-plasma accelerator stability via high-bandwidth longitudinal focal position stabilization of a 100 TW-class laser system

Laser-plasma accelerators (LPAs) offer an attractive alternative to conventional accelerators for the development of compact electron sources and next-generation light sources. Due to orders-of-magnitude larger accelerating gradients, LPAs enable the acceleration of high-brightness electron beams to ultrarelativistic energies in millimeter- to centimeter-scale distances. However, LPA stability is limited by shot-to-shot fluctuations of the driving laser system. Specifically, fluctuations in the final-focus longitudinal position result in correlated instability in LPA electron beam qualities, including total beam charge, average beam energy, and energy spread. We demonstrate active stabilization of the longitudinal focal position for a 100 TW-class laser system. This repetition-rate scalable stabilization system leverages noninvasive wave front monitoring of a copropagating, unamplified kHz pulse train to guide corrective adjustments to the focal position of a 1 Hz amplified drive laser via an upstream telescope on millisecond timescales. In this demonstration, the approach limits standard deviation fluctuations of the amplified drive beam’s longitudinal focal position to ±0.22⁢ mm (representing at least a 53% reduction), achieved with a correction bandwidth that reaches the Nyquist frequency limit. Consequently, we observe marked improvements in both long-term and shot-to-shot LPA stability in terms of charge and spectrum.

Beam control↗

Implementation of a High-Speed Multichannel Data Acquisition System for Magnetic Diagnostics and Plasma Centroid Position Control in ISTTOK

In tokamak and other fusion devices, magnetic control is the main tool that allows to regulate the plasma current, position and shape; it is in charge of actuating the desired plasma current waveform, steering the plasma position to a given set point and maintain the plasma shape close to a prescribed plasma equilibrium. This work describes the application of several physics concepts and computational tools in order to obtain a novel optimal controller for the plasma centroid position, which has been implemented and tested in the real-time plasma control system at the ISTTOK tokamak. A key point for the development of the new control system was the installation of a recently upgraded hardware, that numerically integrates in real-time the magnetic probes signals.

poloidal field coils↗

Design and testing of a phantom and instrumented gynecological applicator based on GaN dosimeter for use in high dose rate brachytherapy quality assurance

Purpose: High dose rate brachytherapy (HDR-BT) is widely used to treat gynecologic, anal, prostate, head, neck, and breast cancers. These treatments are typically administered in large dose per fraction (>5 Gy) and with high-gradient-dose-distributions, with serious consequences in case of a treatment delivery error (e.g., on dwell position and dwell time). Thus, quality assurance (QA) or quality control (QC) should be systematically and independently implemented. This paper describes the design and testing of a phantom and an instrumented gynecological applicator for pretreatment QA and in vivo QC, respectively. Methods: The authors have designed a HDR-BT phantom equipped with four GaN-based dosimeters. The authors have also instrumented a commercial multichannel HDR-BT gynecological applicator by rigid incorporation of four GaN-based dosimeters in four channels. Specific methods based on the four GaN dosimeter responses are proposed for accurate determination of dwell time and dwell position inside phantom or applicator. The phantom and the applicator have been tested for HDR-BT QA in routine over two different periods: 29 and 15 days, respectively. Measurements in dwell position and time are compared to the treatment plan. A modified position–time gamma index is used to monitor the quality of treatment delivery. Results: The HDR-BT phantom and the instrumented applicator have been used to determine more than 900 dwell positions over the different testing periods. The errors between the planned and measured dwell positions are 0.11 ± 0.70 mm (1σ) and 0.01 ± 0.42 mm (1σ), with the phantom and the applicator, respectively. The dwell time errors for these positions do not exhibit significant bias, with a standard deviation of less than 100 ms for both systems. The modified position–time gamma index sets a threshold, determining whether the treatment run passes or fails. The error detectability of their systems has been evaluated through tests on intentionally introduced error protocols. With a detection threshold of 0.7 mm, the error detection rate on dwell position is 22% at 0.5 mm, 96% at 1 mm, and 100% at and beyond 1.5 mm. On dwell time with a dwell time threshold of 0.1 s, it is 90% at 0.2 s and 100% at and beyond 0.3 s. Conclusions: The proposed HDR-BT phantom and instrumented applicator have been tested and their main characteristics have been evaluated. These systems perform unsupervised measurements and analysis without prior treatment plan information. They allow independent verification of dwell position and time with accuracy of measurements comparable with other similar systems reported in the literature.

60 APPLIED LIFE SCIENCES↗

Lateral position detection and control for friction stir systems

A friction stir system for processing at least a first workpiece includes a spindle actuator coupled to a rotary tool comprising a rotating member for contacting and processing the first workpiece. A detection system is provided for obtaining information related to a lateral alignment of the rotating member. The detection system comprises at least one sensor for measuring a force experienced by the rotary tool or a parameter related to the force experienced by the rotary tool during processing, wherein the sensor provides sensor signals. A signal processing system is coupled to receive and analyze the sensor signals and determine a lateral alignment of the rotating member relative to a selected lateral position, a selected path, or a direction to decrease a lateral distance relative to the selected lateral position or selected path. In one embodiment, the friction stir system can be embodied as a closed loop tracking system, such as a robot-based tracked friction stir welding (FSW) or friction stir processing (FSP) system.

Fleming, Paul↗

Electron energy distribution functions measured by Langmuir probe with optical emission spectroscopy in very high frequency capacitive discharge in nitrogen

By using a rf compensated Langmuir probe and optical emission spectroscopy, the effects of driving frequency (13.56-50 MHz) on the electron energy probability function (EEPF), electron density, electron temperature, and the vibrational and rotational temperatures in capacitively coupled nitrogen discharge were investigated. Measurements were performed in the pressure range 60-200 mTorr, and at a fixed voltage of 140 V (peak-to-peak). With increasing the driving frequency, the dissipated power and electron density markedly increased along with the intensity of the optical emission lines belonging to the 2nd positive (337.1 nm) and 1st negative systems (391.4 nm) of N{sub 2}. The EEPF at low pressure 60 mTorr is two-temperature (bi-Maxwellian) distribution, irrespective of the driving frequency, in contrast with argon and helium discharges in the similar conditions. The mechanism forming such bi-Maxwellian shape was explained by two combined effects: one is the collisionless sheath-heating effect enhancing the tail electron population, and the other is the collision-induced reduction of electrons at the energy 2-4 eV where the collision cross-section for the vibrational excitation has a resonantly large peak. The two-temperature EEPF structure was basically retained at moderate pressure 120 mTorr and high pressure 200 mTorr. The vibrational temperature T{sub vib} and rotational temperature T{sub rot} are measured for the sequence ({Delta}{nu}=-2) of N{sub 2} second positive system (C{sup 3}{Pi}{sub u}{yields}B{sup 3}{Pi}{sub g}) using the method of comparing the measured and calculated spectra with a chi-squared minimization procedure. It was found that, both of T{sub vib} and T{sub rot} are a weakly dependent on driving frequency at low pressure 60 mTorr. At higher pressure (120 and 200 mTorr), T{sub vib} rises monotonically with the driving frequency, whereas the T{sub rot} slightly decreases with frequency below 37 MHz, beyond which it relatively increases or saturated.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

MARVELS-1: A FACE-ON DOUBLE-LINED BINARY STAR MASQUERADING AS A RESONANT PLANETARY SYSTEM AND CONSIDERATION OF RARE FALSE POSITIVES IN RADIAL VELOCITY PLANET SEARCHES

We have analyzed new and previously published radial velocity (RV) observations of MARVELS-1, known to have an ostensibly substellar companion in a {approx}6 day orbit. We find significant ({approx}100 m s{sup -1}) residuals to the best-fit model for the companion, and these residuals are naievely consistent with an interior giant planet with a P = 1.965 days in a nearly perfect 3:1 period commensurability (|P{sub b} /P{sub c} - 3| < 10{sup -4}). We have performed several tests for the reality of such a companion, including a dynamical analysis, a search for photometric variability, and a hunt for contaminating stellar spectra. We find many reasons to be critical of a planetary interpretation, including the fact that most of the three-body dynamical solutions are unstable. We find no evidence for transits, and no evidence of stellar photometric variability. We have discovered two apparent companions to MARVELS-1 with adaptive optics imaging at Keck; both are M dwarfs, one is likely bound, and the other is likely a foreground object. We explore false-alarm scenarios inspired by various curiosities in the data. Ultimately, a line profile and bisector analysis lead us to conclude that the {approx}100 m s{sup -1} residuals are an artifact of spectral contamination from a stellar companion contributing {approx}15%-30% of the optical light in the system. We conclude that origin of this contamination is the previously detected RV companion to MARVELS-1, which is not, as previously reported, a brown dwarf, but in fact a G dwarf in a face-on orbit.

79 ASTRONOMY AND ASTROPHYSICS↗

Validation of Kepler's multiple planet candidates. III. Light curve analysis and announcement of hundreds of new multi-planet systems

The Kepler mission has discovered more than 2500 exoplanet candidates in the first two years of spacecraft data, with approximately 40% of those in candidate multi-planet systems. The high rate of multiplicity combined with the low rate of identified false positives indicates that the multiplanet systems contain very few false positive signals due to other systems not gravitationally bound to the target star. False positives in the multi-planet systems are identified and removed, leaving behind a residual population of candidate multi-planet transiting systems expected to have a false positive rate less than 1%. We present a sample of 340 planetary systems that contain 851 planets that are validated to substantially better than the 99% confidence level; the vast majority of these have not been previously verified as planets. We expect ∼two unidentified false positives making our sample of planet very reliable. We present fundamental planetary properties of our sample based on a comprehensive analysis of Kepler light curves, ground-based spectroscopy, and high-resolution imaging. Since we do not require spectroscopy or high-resolution imaging for validation, some of our derived parameters for a planetary system may be systematically incorrect due to dilution from light due to additional stars in the photometric aperture. Nonetheless, our result nearly doubles the number verified exoplanets.

79 ASTRONOMY AND ASTROPHYSICS↗

Performance of a Half-Heusler Thermoelectric Generator for Automotive Application

Thermoelectric generators (TEGs) have been researched and developed for harvesting energy from otherwise wasted heat. For automotive applications this will most likely involve using internal combustion engine exhaust as the heat source, with the TEG positioned after the catalyst system. Applications to exhaust gas recirculation systems and compressed air coolers have also been suggested. A thermoelectric generator based on half-Heusler thermoelectric materials was developed, engineered, and fabricated, targeting a gasoline passenger sedan application. This generator was installed on a gasoline engine exhaust system in a dynamometer cell, and positioned immediately downstream of the closecoupled three-way catalyst. The generator was characterized using a matrix of steady-state conditions representing the important portions of the engine map. Detailed performance results are presented. Measurements indicate the generator can produces over 300 W of power with 900 °C exhaust at relatively high flow rates, but less than 50 W when the exhaust is 600 °C and at lower flow rates. The latter condition is typical of standard test cycles and most driving scenarios.

33 ADVANCED PROPULSION SYSTEMS↗

Influence of Laser Radiation Power Density on the Intensity of Spectral Lines for Main Components in a Clay Laser-Induced Plasma

We have studied the intensity of the spectral lines for the main components in clay: Al I 309.4 nm, Al II 358.7 nm, Mg II 279.6 nm, Ti II 323.6 nm vs. the position of the object relative to the focus of the optical system when the samples are exposed to single laser pulses from a YAG:Nd{sup 3+} laser. We have determined the permissible ranges for positioning the object relative to the focus of the optical system (positive and negative defocusing) for which there is practically no change in the reproducibility of the intensity for the spectral lines for red and white clay samples. We show that the position of the object relative to the focus of the optical system should be within the range ΔZ ~ ±1.5 mm for optimal laser pulse energies for the analyte spectral lines. We have calculated the radiation flux density for different laser pulse energies and different distances from the focus to the object. We have shown experimentally that reducing the radiation flux density leads to a decrease in the intensity of the analyte spectral lines.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗