Search NASA⌕ Search

SEARCH · Search NASA

Results for “Power system stability”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 721 records · Page 40

Development of economically viable, highly integrated, highly modular SEGIS architecture

Initiated in 2008, the SEGIS initiative is a partnership involving the U.S. DOE, Sandia National Laboratories, private sector companies, electric utilities, and universities. Projects supported under the initiative have focused on the complete-system development of solar technologies, with the dual goal of expanding renewable PV applications and addressing new challenges of connecting large-scale solar installations in higher penetrations to the electric grid. Petra Solar, Inc., a New Jersey-based company, received SEGIS funds to develop solutions to two of these key challenges: integrating increasing quantities of solar resources into the grid without compromising (and likely improving) power quality and reliability, and moving the design from a concept of intelligent system controls to successful commercialization. The resulting state-of-the art technology now includes a distributed photovoltaic (PV) architecture comprising AC modules that not only feed directly into the electrical grid at distribution levels but are equipped with new functions that improve voltage stability and thus enhance overall grid stability. This integrated PV system technology, known as SunWave, has applications for 'Power on a Pole,' and comes with a suite of technical capabilities, including advanced inverter and system controls, micro-inverters (capable of operating at both the 120V and 240V levels), communication system, network management system, and semiconductor integration. Collectively, these components are poised to reduce total system cost, increase the system's overall value and help mitigate the challenges of solar intermittency. Designed to be strategically located near point of load, the new SunWave technology is suitable for integration directly into the electrical grid but is also suitable for emerging microgrid applications. SunWave was showcased as part of a SEGIS Demonstration Conference at Pepco Holdings, Inc., on September 29, 2011, and is presently undergoing further field testing as a prelude to improved and expanded commercialization.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Power conversion in electrical networks

Aspects of dc to dc conversion were studied in terms of a class of switching voltage regulators from a stability viewpoint. Background concepts of nonlinear system theory were considered, including the problem of obtaining suitable realizations for a class of positive operators. It is shown that the state evolution equations for a power conversion network are in general of bilinear form, and that the theory of lie groups and lie algebras is useful in analyzing such systems. The feedback stabilization of a class of bilinear systems whose state space is a manifold is also discussed.

Wood, J. R.↗

Time Delay of Wide Area Damping Control in Urban Power Grid: Model-Based Analysis and Data-Driven Compensation

Due to the rapid development of economies, large urban cities consume an increasing amount of energy and have a higher requirement for power quality. Voltage source converter based high voltage direct current (VSC-HVDC) is a promising device to transmit clean power from remote regions to urban power systems, while also providing wide area damping control (WADC) for frequency stabilization. However, the time-delay naturally existing in the VSC-HVDC system may degrade the performance of WADC and even result in instability. To address this issue, this paper develops a time-delay correction control strategy for VSC-HVDC damping control in urban power grids. First, a small signal model of WADC is built to analyze the negative impacts of time delay. Then, a data-driven approach is proposed to compensate for the inherent time delay in VSC-HVDC damping control. The extensive training data will be generated under various disturbances. After offline training, the long short-term memory network (LSTM) can be implemented online to predict the actual frequency deviation based on real-time measurements. Finally, the proposed method is validated through MATLAB-Simulink in a two-area four-machine system. The results indicate that the data-driven compensation has a strong generalization ability for random delay time constants and can improve the performance of WADC significantly.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Intelligently Partitioned Phasor-EMT Hybrid Simulations of Large-Scale, High-IBR Power Systems

As the penetration level of power electronics-interfaced renewables such as photovoltaics (PV) and wind has surged in modern electric grids, new operational risks caused by the dynamics of those inverter-based resources (IBRs) are emerging in parallel. Lessons learned from various grid events include that the impact of IBRs on system-level grid stability will become prominent along with the increase of renewables and that the short-timescale dynamic impacts of IBRs on grid stability are not fully captured by current commercial dynamic simulation tools [1] [2]. For example, IBRs can be controlled to mitigate those destabilizing interactions, but conventional phasor-domain tools (e.g. PSS/E, PSLF) often cannot capture that; likewise, the existing electromagnetic transient (EMT) simulation tools (e.g. PSCAD, EMTP) can simulate detailed IBR controls, but for large power systems with many IBRs, slow simulation speeds severely impede the ability to study dynamic events [3] [4]. Massively paralleling simulations using high-performance computing (HPC) can help address this, especially now that cloud-based HPC capability is widely available, but today s EMT tools are not HPC-compatible, and parallelization of dynamic simulation solvers is not trivial because each region can dynamically affect the others. Thus, dynamic simulation of grids with very large numbers of IBRs potentially poses a barrier to the ongoing energy transition.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Inertia Estimation Under High Penetration of Inverter-based Resources

Many types of renewable energy sources, especially solar and wind generation, are connected to the electric grid through power-electronic-based interfaces (inverters). These inverter-based resources (IBRs) are mechanically decoupled from the grid, which reduces system inertia and thus may compromise its stability and reliability. In this study, we examine the impact of high penetration of IBRs on the power grid’s inertia. To achieve this, we intentionally introduce disturbances into a simulation case study, such as a step load change, to observe and record the system’s frequency responses. This study offers a nuanced understanding of how the integration of IBRs affects grid stability, and it provides essential guidance for future grid management and resilience strategies.

Yadav, Ajay↗

Cross-Border Electricity Trade between India and Sri Lanka: Impact on Power System Operations

Recent developments in South Asia have the potential to increase the incentives for cross-border energy trade (CBET) between India and Sri Lanka. India's surplus power, including from its rapid expansion of wind and solar generation, provides an incentive for it to increase investment returns through exports. Sri Lanka is considering options to increase its power supply, and CBET could alleviate the need for investments in new thermal generation capacity, while giving it access to India's large and diverse power system. Finally, CBET can facilitate renewable energy (RE) integration by allowing the two countries to more efficiently harness balancing resources and smooth out wind and solar variability over larger geographic areas. This study builds on several prior analyses of a potential high-voltage direct current transmission link between India and Sri Lanka. Uniquely, the study makes use of a detailed one-year, 30-minute resolution unit commitment and economic dispatch (UC&ED) model of both countries to examine the technical and economic impacts of CBET between India and Sri Lanka in the year 2025. The study finds that CBET, enabled by a 500-MW high voltage direct current transmission link, could generate annual production cost savings of USD 180 million and improve power system operations. Through better utilization of the most efficient generators, generation from relatively expensive natural gas plants in Sri Lanka is displaced by lower cost imports from India. In addition, increased flexibility through exports reduces RE curtailment in India's Southern region by 400 GWh annually. While the study captures many previously unconsidered intertemporal operational constraints, it does not provide a complete characterization of system operations with a high-voltage direct current interconnection. Additional work should include a dynamic analysis of system stability following interruptions to the direct current interconnection, an AC power flow analysis and consideration of any non-technical barriers to trade which might prevent the optimization of CBET between India and Sri Lanka at 30-minute timescales.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Adaptive Narrowband Damping for Improving Harmonic Stability of Modular Multilevel Converter

Harmonic instability events between modular multilevel converter (MMC) and ac systems have been widely reported in recent years. To damp harmonic resonance, this paper proposes an adaptive narrowband damping control that automatically programs, adds, and adjusts the damping around the oscillation frequency when an oscillation is detected. First, the paper presents a low-pass filter design for MMC control loops that pushes all negative damping of the MMC impedance down to the medium-frequency range (< ~ 1000 Hz). Then, an adaptive damping control that uses online oscillation detection is proposed, which can automatically configure the narrowband damper to provide positive damping to the MMC around the detected oscillation frequency. In contrast to existing narrowband damping methods, the proposed adaptive narrowband damper dynamically adjusts the damping gain and the width of the damping range based on continuous monitoring of system resonance conditions (e.g., adjust damping gain to zero when the system resonance disappears). Electromagnetic transient simulation results validate the efficacy of the proposed method in two typical MMC-based power systems.

active damping↗

Efficient Simulation of Cascading Outages Using an Energy Function-Embedded Quasi-Steady-State Model

Here, this paper proposed an energy function-embedded quasi-steady-state model for efficient simulation of cascading outages on a power grid while addressing transient stability concerns. Compared to quasi-steady-state models, the proposed model incorporates short-term dynamic simulation and an energy function method to efficiently evaluate the transient stability of a power grid together with outage propagation without transient stability simulation. Cascading outage simulation using the proposed model conducts three steps for each disturbance such as a line outage. First, it performs time-domain simulation for a short term to obtain a post-disturbance trajectory. Second, along the trajectory, the system state with the local maximum potential energy is found and used as the initial point to search for a relevant unstable equilibrium by Newton's method. Third, the transient energy margin is estimated based on this unstable equilibrium to predict an out-of-step condition with generators. The proposed energy function-embedded quasi-steady-state model is tested in terms of its accuracy and time performance on an NPCC 140-bus power system and compared to a quasi-steady-state model embedding transient stability simulation.

Guo, Zhenping [Univ. of Tennessee, Knoxville, TN (↗

Model-Free Dynamic Voltage Control of Distributed Energy Resource (DER)-Based Microgrids

In this paper, we present a new control technique for sustaining dynamic voltage stability by effective reactive power control and coordination of distributed energy resources (DERs) in microgrids. The proposed control technique is based on model-free control (MFC), which has shown successful operation and improved performance in different domains and applications. This paper presents its first use in the voltage stability of a microgrid setting employing multiple synchronous generator (SG)-based and power electronic (PE)-based DERs. MFC is a computationally efficient, data-driven control technique that does not require modelling of the different components and disturbances in the power system. It is utilized as an online controller to achieve the dynamic voltage stability of a microgrid system under different disturbances and fault conditions. A 21-bus microgrid system fed by multiple DERs is considered as a case study and the overall dynamic voltage stability is investigated using time-domain dynamic simulations. Numerical results show that the proposed MFC provides improvements on the dynamic load bus voltage profiles and requires less computational time as compared to the traditional enhanced microgrid voltage stabilizer (EMGVS) scheme. Due to its simplicity and low computational requirement, MFC can be easily implemented in resource-constrained computing devices such as smart inverters.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Adaptive Narrowband Damping for Improving Harmonic Stability of Modular Multilevel Converter: Preprint

Harmonic instability events between modular multilevel converter (MMC) and ac systems have been widely reported in recent years. To resolve it, this paper proposes an adaptive narrowband damping control that automatically programs, adds and adjusts damping around the oscillation frequency when detect the oscillation. The paper first presents a low-pass filter design for MMC control loops, which pushes all negative damping of MMC impedance down to the medium frequency range (< approximately 1000 Hz). This makes narrowband damping can be more targeted and easier to design because multiple harmonic oscillations are avoided. An adaptive damping control that uses online oscillation detection is then proposed, which can automatically configure the narrowband damper to provide damping to the MMC at the detected oscillation frequency. In contrast to existing narrowband damping methods, the proposed adaptive narrowband damper adjusts the damping gain (e.g., to zero when system resonance disappears) and the width of the damping range automatically based on continuous monitoring of system resonance conditions. Electromagnetic transient (EMT) simulation results validate the efficacy of the proposed method in two typical MMC-based power systems.

active damping↗

van der Waals corrected density functionals for cylindrical surfaces: Ammonia and nitrogen dioxide adsorbed on a single-walled carbon nanotube

In this work, we extend the damped Zaremba-Kohn model (dZK) for long-range dispersion interaction between a molecule and a planar surface to molecules adsorbed on a curved cylindrical surface, and employ this extended model as an additive correction to the semilocal density functionals PBE (Perdew-Burke-Ernzerhof) and SCAN (strongly constrained and appropriately normed). The resulting PBE+vdW (van der Waals)-dZK and SCAN+vdW-dZK are applied to two systems, NH3 and NO2 molecules adsorbed on a single-wall carbon nanotube (CNT), for calculations of binding energies and equilibrium distances. For comparison, the results from vdW nonlocal functionals, such as SCAN+rVV10 and PBE+rVV10, are also presented. The binding energies from PBE+rVV10 (Vydrov and Van Voorhis), SCAN+rVV10, PBE+vdW-dZK, and SCAN+vdW-dZK are about 70–115 meV for the system of CNT + NH 3 and 300–500 meV for the system of CNT + NO 2 . The results from PBE+vdW-dZK and SCAN+vdW-dZK are closer to each other than those from PBE+rVV10 and SCAN+rVV10 are. The relatively closer results from PBE+vdW-dZK and SCAN+vdW-dZK indicate the consistency of our developed vdW–dZK model for cylindrical surfaces. All methods, including PBE, SCAN, PBE+rVV10, SCAN+rVV10, PBE+vdW-dZK, and SCAN+vdW-dZK, give approximately the same binding energy differences between two adsorption configurations (types I and II) for the two systems. This implies that the two adsorption sites have approximately the same adsorption stability. The exponent of the vdW interaction power law from our vdW-dZK model for the two systems is about 0 at short distance, largely due to the damping factor, and tends slowly to –4 to –4.5 at distances D about 20–50 Å. At even larger distances, the vdW power-law exponent approaches –5. This feature is very similar to the one calculated with random-phase approximation and renormalization group approaches, supporting the applicability of our methods. Our developed vdW-dZK method provides a highly efficient and reliable method for large systems with cylindrical surfaces, such as vdW interactions with nanotubes.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Same Goal, Different Pathways for Energy Transition: A More Holistic, Multisector, Community-Driven Approach

Low- and zero-carbon power systems are central to global decarbonization efforts. Costs for renewable energy (RE) and storage have fallen significantly, and advances in technologies and practices have improved the grid flexibility and stability needed to maintain the reliability of high-RE systems. Zero-carbon power systems, in turn, enable deep decarbonization through the electrification of other sectors, including transportation, buildings, and industry.

100% clean electricity↗

Dynamic Model Validation of PV Inverters Under Short-Circuit Conditions: Preprint

Photovoltaic (PV) modules have dramatically decreased in price in the past few years, spurring the expansion of photovoltaic deployment. Residential and commercial rooftop installations are connected to the distribution network; large-scale installation PV power plants (PVPs) have benefited from tax incentives and the low cost of PV modules. As the level penetration of PV generation increases, the impact on power system reliability will also be greater. Utility power system planners must consider the role of PV generation in power systems more realistically by representing PV generation in dynamic stability analyses. Dynamic models of PV inverters have been developed in the positive sequence representation. NREL has developed a PV inverter dynamic model in PSCAD/EMTDC. This paper validates the dynamic model with an actual hardware bench test conducted by Southern California Edison's Distributed Energy Resources laboratory. All the fault combinations -- symmetrical and unsymmetrical -- were performed in the laboratory. We compare the simulation results with the bench test results.

14 SOLAR ENERGY↗

Common Electric Power Transmission System Model JSON Schema Specification

The Common Electric Power Transmission System Model (CTM) is an intuitive, extensible, language-agnostic, and error-resistant specification of electric power network components parameter names and units, and relation between components, intended for use by the research community developing new computational methods for power systems operations and simulation. Power system datasets following the CTM specification can be read as dictionaries and manipulated in that form in most programming languages (e.g., Python, Julia, C++). This standard data structure in CTM makes it easy to work in multiple power systems domains (e.g., economic operation, reliability assessment, electricity markets, stability assessment, etc.) without requiring conversions between use-case-specific file formats with information loss in the process. This repository specifies CTM as a JSON Schema, provides documentation, derivate (code-generated) implementations of CTM, and example data and usage of the schema for important use cases.

Aravena Solis, Ignacio↗

Embedded Sensors and Controls to Improve Component Performance and Reliability - System Dynamics Modeling and Control System Design

This report documents the current status of the modeling, control design, and embedded control research for the magnetic bearing canned rotor pump being used as a demonstration platform for deeply integrating instrumentation and controls (I&C) into nuclear power plant components. This pump is a highly inter-connected thermo/electro/mechanical system that requires an active control system to operate. Magnetic bearings are inherently unstable system and without active, moment by moment control, the rotor would contact fixed surfaces in the pump causing physical damage. This report details the modeling of the pump rotordynamics, fluid forces, electromagnetic properties of the protective cans, active magnetic bearings, power electronics, and interactions between different dynamical models. The system stability of the unforced and controlled rotor are investigated analytically. Additionally, controllers are designed using proportional derivative (PD) control, proportional integral derivative (PID) control, voltage control, and linear quadratic regulator (LQR) control. Finally, a design optimization problem that joins the electrical, mechanical, magnetic, and control system design into one problem to balance the opposing needs of various design criteria using the embedded system approach is presented.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Design of multi-mission spacecraft bus

This paper presents preliminary design of a multimission spacecraft bus for meteorological and communications payloads. The meteorological payload uses sun-synchronous circular orbit and the communications payload uses Molniya type orbit to provide communications for areas not covered by geosynchronous communications satellites. The launch vehicles are Pegasus for the meteorological payload and Taurus for the communications payload. The spacecraft bus uses three-axis stabilization consisting of a three reaction wheel system. The electric power system consists of single-axis tracking silicon solar array and Ni2 H2 batteries. The propulsion subsystem consists of six hydrazine thrusters and one propellant tank.

Agrawal, Brij N.↗

Ni/NiCI(2) Reference Electrodes For Na/NiCI(2) Cells

Reference electrodes made of nickel cores with surface layers of nickel chloride proposed for use in molten sodium tetracholoroaluminate electrolytes in experimental sodium/nickel chloride electrochemical cells. These and other sodium/metal chloride cells investigated for use in several applications, including powering electric vehicles and leveling loads in power-distribution systems. Offers potential advantages of greater durability, greater stability and reproducibility of electrochemical potentials, less sensitivity of electrochemical potentials to variations in compositions of electrolytes, and greater compatibility with cathodes, made of nickel chloride.

Bugga, Ratnakumar↗

High average power 88 W OPCPA system for high-repetition-rate experiments at the LCLS x-ray free-electron laser

Here, we present a 100 kHz, sub-20 fs optical parametric chirped-pulse amplifier (OPCPA) system delivering 88.6 W average power at a center wavelength of 800 nm. The seed pulses are derived from the pump laser via white-light continuum generation and are amplified in three non-collinear OPCPA stages. The final two high-power stages are pumped with a 661 W Yb:YAG InnoSlab amplifier. A simple and robust design is used for the OPCPA system to avoid thermal effects and enhance long-term stability, resulting in excellent beam quality and high conversion efficiency. To the best of our knowledge, this is the highest average power OPCPA system reported to date.

47 OTHER INSTRUMENTATION↗