Search NASA⌕ Search

SEARCH · Search NASA

Results for “Precise timing electronics”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 721 records · Page 40

Sci-Fri PM: Radiation Therapy, Planning, Imaging, and Special Techniques - 11: Quantification of chest wall motion during deep inspiration breast hold treatments using cine EPID images and a physics based algorithm

Purpose: This work presents an algorithm used to quantify intra-fraction motion for patients treated using deep inspiration breath hold (DIBH). The algorithm quantifies the position of the chest wall in breast tangent fields using electronic portal images. Methods: The algorithm assumes that image profiles, taken along a direction perpendicular to the medial border of the field, follow a monotonically and smooth decreasing function. This assumption is invalid in the presence of lung and can be used to calculate chest wall position. The algorithm was validated by determining the position of the chest wall for varying field edge positions in portal images of a thoracic phantom. The algorithm was used to quantify intra-fraction motion in cine images for 7 patients treated with DIBH. Results: Phantom results show that changes in the distance between chest wall and field edge were accurate within 0.1 mm on average. For a fixed field edge, the algorithm calculates the position of the chest wall with a 0.2 mm standard deviation. Intra-fraction motion for DIBH patients was within 1 mm 91.4% of the time and within 1.5 mm 97.9% of the time. The maximum intra-fraction motion was 3.0 mm. Conclusions: A physics based algorithm was developed and can be used to quantify the position of chest wall irradiated in tangent portal images with an accuracy of 0.1 mm and precision of 0.6 mm. Intra-fraction motion for patients treated with DIBH at our clinic is less than 3 mm.

60 APPLIED LIFE SCIENCES↗

CO oxidation over ceria supported Au 22 nanoclusters: Shape effect of the support

Gold (Au) nanoclusters have recently emerged as ideal models for understanding Au catalysis, because the nanosized Au particles have precise atomic numbers and uniform size. Here, in this work, we studied for the first time the support shape effect on the catalysis of Au nanoclusters by using CO oxidation as a model reaction. Au 22 (L 8 ) 6 (L = 1,8-bis(diphenylphosphino) octane) nanoclusters were supported on CeO 2 rods or cubes, then pretreated at different temperatures (up to 673 K), allowing the gradual removal of the organic phosphine ligands. CO oxidation test over these differently pretreated samples shows that CeO 2 rods are much better supports than cubes for Au 22 nanoclusters in enhancing the reaction rate. In situ IR spectroscopy coupled with CO adsorption indicates that the shape of CeO 2 support can impact the nature and quantity of exposed Au sites, as well as the efficiency of organic ligand removal. Although CeO 2 rods are helpful in exposing a greater percentage of total Au sites upon ligands removal, the percentage of active Au sites (denoted by Au δ+ , 0 < δ < 1) is lower than that on CeO 2 cubes. The in situ extended X-ray absorption spectroscopy (EXAFS) and high-angle annular dark-field scanning transmission electron microscopy (HAADF-STEM) results show that the Au nanoclusters bound more strongly to the CeO 2 rods than to the cubes where the Au nanoclusters show more sintering. Considering the typical redox mechanism for CO oxidation over supported Au nanoclusters and nanoparticles, it is concluded that the reactivity of the lattice oxygen of CeO 2 is the determining factor for CO oxidation over Au 22 /CeO 2 . Lastly, CeO 2 rods offer more reactive lattice oxygen and abundant oxygen vacancies than the cubes and thus make the rods a superior support for Au nanoclusters in catalyzing low temperature CO oxidation.

36 MATERIALS SCIENCE↗

Radiative corrections to superallowed beta decays at $\mathcal{O}\left({\alpha}^2Z\right)$

We compute $\mathcal{O}\left({\alpha}^2Z\right)$ radiative corrections to superallowed β decays with a heavy-particle effective field theory that systematically describes the interactions of low-energy ultrasoft photons with nuclei. We calculate two-loop virtual and one-loop real-virtual amplitudes by reducing the Feynman integrals to a set of master integrals, which we solve analytically using a variety of techniques. These techniques can be applied to other phenomenologically interesting observables. The ultrasoft corrections can then be combined with contributions arising from the exchange of potential photons to obtain the complete $\mathcal{O}\left({\alpha}^2Z\right)$ correction to the decay rate, with resummation of large logarithms of the electron energy times the nuclear radius. We find that $\mathcal{O}\left({\alpha}^2Z\right)$ ultrasoft loops induce a relative correction to the decay rate that ranges from 0.7 ∙ 10 −3 in the decay of 10 C to 3.6 ∙ 10 −3 in the decay of 54 Co, and will thus impact the extraction of V ud at the permille level. We show that the inclusion of these corrections reduces the residual renormalization scale dependence of the decay rate to a negligible level, making missing ultrasoft perturbative corrections a subdominant source of theoretical uncertainty.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Quantum Perturbation Theory Using Tensor Cores and a Deep Neural Network

In this work, time-independent quantum response calculations are performed using Tensor cores. This is achieved by mapping density matrix perturbation theory onto the computational structure of a deep neural network. The main computational cost of each deep layer is dominated by tensor contractions, i.e., dense matrix–matrix multiplications, in mixed-precision arithmetics, which achieves close to peak performance. Quantum response calculations are demonstrated and analyzed using self-consistent charge density-functional tight-binding theory as well as coupled-perturbed Hartree–Fock theory. For linear response calculations, a novel parameter-free convergence criterion is presented that is well-suited for numerically noisy low-precision floating point operations and we demonstrate a peak performance of almost 200 Tflops using the Tensor cores of two Nvidia A100 GPUs.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Accurate Determination of the Values of Fundamental Physical Constants: The Basis of the New “Quantum” SI Units

The metric system appeared as the system of units designed for macroscopic (laboratory scale) measurements. The progress in accurate determination of the values of quantum constants (such as the Planck constant) in SI units shows that the capabilities in high-precision measurement of microscopic and macroscopic quantities in terms of the same units have increased substantially recently. At the same time, relative microscopic measurements (for example, the comparison of atomic transition frequencies or atomic masses) are often much more accurate than relative measurements of macroscopic quantities. This is the basis for the strategy to define units in microscopic phenomena and then use them on the laboratory scale, which plays a crucial role in practical methodological applications determined by everyday life and technologies. The international CODATA task group on fundamental constants regularly performs an overall analysis of the precision world data (the so-called Adjustment of the Fundamental Constants ) and publishes their recommended values. The most recent evaluation was based on the data published by the end of 2014; here, we review the corresponding data and results. The accuracy in determination of the Boltzmann constant has increased, the consistency of the data on determination of the Planck constant has improved; it is these two dimensional constants that will be used in near future as the basis for the new definition of the kelvin and kilogram, respectively. The contradictions in determination of the Rydberg constant and the proton charge radius remain. The accuracy of determination of the fine structure constant and relative atomic weight of the electron has improved. Overall, we give a detailed review of the state of the art in precision determination of the values of fundamental constants. The mathematical procedure of the Adjustment, the new data and results are considered in detail. The limitations due to macroscopic properties of material standards (such as the International prototype of the kilogram) and the isotopic composition of substances involved in precision studies in general (as standard measures for the triple point of water) and, in particular, in the determination of the fundamental constants are discussed. The perspectives of the introduction of the new quantum units, which will be free from the mentioned problems, are considered. Many physicists feel no sympathy for the International system of units (SI), believing that it does not properly reflect the character of physical laws. In fact, there are three parallel systems, namely the systems of quantities, system of their units and the related standards. The definition of the units, in particular, the SI units, above all, reflects our ability to perform precision measurements of physical values under certain conditions, in particular, to create appropriate standards. This requirement is not related to the beauty of fundamental laws of nature. More accurate determination of the fundamental constants is one of the areas where we accumulate such experience.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Using DUNE to shed light on the electromagnetic properties of neutrinos

We study future DUNE sensitivity to various electromagnetic couplings of neutrinos, including magnetic moments, milli-charges, and charge radii. The DUNE PRISM capabilities play a crucial role in constraining the electron flavored couplings. We find that DUNE will be able to place the strongest beam based constraint on the muon-neutrino magnetic moment by improving on LSND’s bounds by roughly a factor of two, although Borexino’s constraint from solar neutrinos will be stronger. For the muon neutrino millicharge DUNE can place the leading beam based bound, with two orders of magnitude improvement compared to the existing COHERENT constraint, suggesting that DUNE can be useful for light mediators more generally. Despite this strength, the millicharge bounds are not competitive with strong bounds from stellar cooling, beta-decay, and matter stability. Finally, DUNE may be able to test the SM prediction for the muon neutrino charge radius, by placing a constraint two times better than CHARM-II and CCFR experiments.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Examination of decay heat measurements and their relevance for understanding the origin of the reactor antineutrino anomaly

Measurements of the decay energy released as a function of time following the thermal neutron induced fission of 235 U and 239,241 Pu were performed in the 1970s at Oak Ridge National Laboratory with the purpose of quantifying possible loss of coolant accident scenarios. The derivative of this decay energy with respect to time, known in technical parlance as decay heat, is mainly composed of two terms, that of the electrons produced together with antineutrinos in the $β$-minus decay of the neutron-rich fission products, and that of the $γ$ rays produced in the subsequent decay of excited nuclear levels. In this work we study if this extensive set of decay energy measurements can be used to assess the reactor antineutrino anomaly, that is, the approximately 5% deficit of electron antineutrinos produced by nuclear reactors, first deduced by Mention and collaborators in 2011, and observed by the major reactor antineutrino experiments since. Furthermore, with the assistance of nuclear databases, we are able to obtain the ratio of electron spectra under equilibrium conditions for 235 U to 239 Pu, in better agreement with the lower trend recently reported by Kopeikin and collaborators, as well as those for 235 U to 241 Pu and 241 Pu to 239 Pu, which do not agree well with those measured at the Institut Laue-Langevin in the 1980s. We conclude that a new experimental campaign is needed to measure the electron spectra utilizing a high resolution and signal-to-noise-ratio electron spectrometer and a highly precise fission normalization procedure.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Characterization of the 1S–2S transition in antihydrogen

In 1928, Dirac published an equation1 that combined quantum mechanics and special relativity. Negative-energy solutions to this equation, rather than being unphysical as initially thought, represented a class of hitherto unobserved and unimagined particles—antimatter. The existence of particles of antimatter was confirmed with the discovery of the positron2 (or anti-electron) by Anderson in 1932, but it is still unknown why matter, rather than antimatter, survived after the Big Bang. As a result, experimental studies of antimatter3,4,5,6,7, including tests of fundamental symmetries such as charge–parity and charge–parity–time, and searches for evidence of primordial antimatter, such as antihelium nuclei, have high priority in contemporary physics research. The fundamental role of the hydrogen atom in the evolution of the Universe and in the historical development of our understanding of quantum physics makes its antimatter counterpart—the antihydrogen atom—of particular interest. Current standard-model physics requires that hydrogen and antihydrogen have the same energy levels and spectral lines. The laser-driven 1S–2S transition was recently observed8 in antihydrogen. Here we characterize one of the hyperfine components of this transition using magnetically trapped atoms of antihydrogen and compare it to model calculations for hydrogen in our apparatus. We find that the shape of the spectral line agrees very well with that expected for hydrogen and that the resonance frequency agrees with that in hydrogen to about 5 kilohertz out of 2.5 × 1015 hertz. This is consistent with charge–parity–time invariance at a relative precision of 2 × 10-12—two orders of magnitude more precise than the previous determination8—corresponding to an absolute energy sensitivity of 2 ×10-20 GeV.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

The star formation histories of local group dwarf galaxies. I. Hubble space telescope/wide field planetary camera 2 observations

We present uniformly measured star formation histories (SFHs) of 40 Local Group (LG) dwarf galaxies based on color-magnitude diagram (CMD) analysis from archival Hubble Space Telescope imaging. We demonstrate that accurate SFHs can be recovered from CMDs that do not reach the oldest main sequence turn-off (MSTO), but emphasize that the oldest MSTO is critical for precisely constraining the earliest epochs of star formation. We find that: (1) the average lifetime SFHs of dwarf spheroidals (dSphs) can be approximated by an exponentially declining SFH with τ ∼ 5 Gyr; (2) lower luminosity dSphs are less likely to have extended SFHs than more luminous dSphs; (3) the average SFHs of dwarf irregulars (dIrrs), transition dwarfs, and dwarf ellipticals can be approximated by the combination of an exponentially declining SFH (τ ∼ 3-4 Gyr) for lookback ages >10-12 Gyr ago and a constant SFH thereafter; (4) the observed fraction of stellar mass formed prior to z = 2 ranges considerably (80% for galaxies with M < 10{sup 5} M{sub ☉} to 30% for galaxies with M > 10{sup 7} M{sub ☉}) and is largely explained by environment; (5) the distinction between 'ultra-faint' and 'classical' dSphs is arbitrary; (6) LG dIrrs formed a significantly higher fraction of stellar mass prior to z = 2 than the Sloan Digital Sky Survey galaxies from Leitner and the SFHs from the abundance matching models of Behroozi et al. This may indicate higher than expected star formation efficiencies at early times in low mass galaxies. Finally, we provide all the SFHs in tabulated electronic format for use by the community.

79 ASTRONOMY AND ASTROPHYSICS↗

Imaging surface plasmon polaritons using proximal self-assembled InGaAs quantum dots

We present optical investigations of hybrid plasmonic nanosystems consisting of lithographically defined plasmonic Au-waveguides or beamsplitters on GaAs substrates coupled to proximal self-assembled InGaAs quantum dots. We designed a sample structure that enabled us to precisely tune the distance between quantum dots and the sample surface during nano-fabrication and demonstrated that non-radiative processes do not play a major role for separations down to ∼10 nm. A polarized laser beam focused on one end of the plasmonic nanostructure generates propagating surface plasmon polaritons that, in turn, create electron-hole pairs in the GaAs substrate during propagation. These free carriers are subsequently captured by the quantum dots ∼25 nm below the surface, giving rise to luminescence. The intensity of the spectrally integrated quantum dot luminescence is used to image the propagating plasmon modes. As the waveguide width reduces from 5 μm to 1 μm, we clearly observe different plasmonic modes at the remote waveguide end, enabling their direct imaging in real space. This imaging technique is applied to a plasmonic beamsplitter facilitating the determination of the splitting ratio between the two beamsplitter output ports as the interaction length L{sub i} is varied. A splitting ratio of 50:50 is observed for L{sub i}∼9±1 μm and 1 μm wide waveguides for excitation energies close to the GaAs band edge. Our experimental findings are in good agreement with mode profile and finite difference time domain simulations for both waveguides and beamsplitters.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Physiologically gated microbeam radiation using a field emission x-ray source array

Purpose: Microbeam radiation therapy (MRT) uses narrow planes of high dose radiation beams to treat cancerous tumors. This experimental therapy method based on synchrotron radiation has been shown to spare normal tissue at up to 1000 Gy of peak entrance dose while still being effective in tumor eradication and extending the lifetime of tumor-bearing small animal models. Motion during treatment can lead to significant movement of microbeam positions resulting in broader beam width and lower peak to valley dose ratio (PVDR), which reduces the effectiveness of MRT. Recently, the authors have demonstrated the feasibility of generating microbeam radiation for small animal treatment using a carbon nanotube (CNT) x-ray source array. The purpose of this study is to incorporate physiological gating to the CNT microbeam irradiator to minimize motion-induced microbeam blurring. Methods: The CNT field emission x-ray source array with a narrow line focal track was operated at 160 kVp. The x-ray radiation was collimated to a single 280 μm wide microbeam at entrance. The microbeam beam pattern was recorded using EBT2 Gafchromic{sup ©} films. For the feasibility study, a strip of EBT2 film was attached to an oscillating mechanical phantom mimicking mouse chest respiratory motion. The servo arm was put against a pressure sensor to monitor the motion. The film was irradiated with three microbeams under gated and nongated conditions and the full width at half maximums and PVDRs were compared. An in vivo study was also performed with adult male athymic mice. The liver was chosen as the target organ for proof of concept due to its large motion during respiration compared to other organs. The mouse was immobilized in a specialized mouse bed and anesthetized using isoflurane. A pressure sensor was attached to a mouse's chest to monitor its respiration. The output signal triggered the electron extraction voltage of the field emission source such that x-ray was generated only during a portion of the mouse respiratory cycle when there was minimum motion. Parallel planes of microbeams with 12.4 Gy/plane dose and 900 μm pitch were delivered. The microbeam profiles with and without gating were analyzed using γ-H2Ax immunofluorescence staining. Results: The phantom study showed that the respiratory motion caused a 50% drop in PVDR from 11.5 when there is no motion to 5.4, whereas there was only a 5.5% decrease in PVDR for gated irradiation compared to the no motion case. In thein vivo study, the histology result showed gating increased PVDR by a factor of 2.4 compared to the nongated case, similar to the result from the phantom study. The full width at tenth maximum of the microbeam decreased by 40% in gating in vivo and close to 38% with phantom studies. Conclusions: The CNT field emission x-ray source array can be synchronized to physiological signals for gated delivery of x-ray radiation to minimize motion-induced beam blurring. Gated MRT reduces valley dose between lines during long-time radiation of a moving object. The technique allows for more precise MRT treatments and makes the CNT MRT device practical for extended treatment.

60 APPLIED LIFE SCIENCES↗

Captain Electronics Technical Report

This report details the current layout of the electronics for the mini-CAPTAIN detector system, as well as the lessons learned during commissioning. We will present some electronics suggestions for future LArTPC systems. Mini-CAPTAIN is one of three detectors used in the Cryogenic Apparatus for Precision Tests of Argon Interactions with Neutrino (CAPTAIN) project at Los Alamos National Lab (LANL). The detector uses many of the same electronic components as current and developing LArTPC experiments. This includes the motherboards, service cards, amplifiers and ADC made by Brookhaven National Laboratory (BNL) and the front-end modules (FEM) made by Nevis Labs. The cold electronics performed well in both vacuum and cryogenic environments after months of exposure. Mini-CAPTAIN was tested with two liquid nitrogen and three liquid argon run cycles. The final testing was performed at the Weapons Neutron Research (WNR) facility at LANSCE. Mini-CAPTAIN was able to maintain a clean electrical signal through most of the test cycles. Most noise reduction was achieved with power source filtering and careful attention to the ground configuration. Direct oscilloscope probing on the front-end output provided the fastest analysis and correction of noise sources. Ground path assumptions and integrity were verified with frequent impedance checks. A high voltage break down event damaged some of the channels on the motherboards and a number of the wire decoupling capacitors. This temporarily introduced significant noise on the wire planes due to current leakage. The detector was taken apart and reassembled three times, with successful noise reduction after each activity. The current raw signal-to-noise ratio is 9 to 1.

42 ENGINEERING↗

Multileaf collimator performance monitoring and improvement using semiautomated quality control testing and statistical process control

Purpose: High-quality radiation therapy using highly conformal dose distributions and image-guided techniques requires optimum machine delivery performance. In this work, a monitoring system for multileaf collimator (MLC) performance, integrating semiautomated MLC quality control (QC) tests and statistical process control tools, was developed. The MLC performance monitoring system was used for almost a year on two commercially available MLC models. Control charts were used to establish MLC performance and assess test frequency required to achieve a given level of performance. MLC-related interlocks and servicing events were recorded during the monitoring period and were investigated as indicators of MLC performance variations. Methods: The QC test developed as part of the MLC performance monitoring system uses 2D megavoltage images (acquired using an electronic portal imaging device) of 23 fields to determine the location of the leaves with respect to the radiation isocenter. The precision of the MLC performance monitoring QC test and the MLC itself was assessed by detecting the MLC leaf positions on 127 megavoltage images of a static field. After initial calibration, the MLC performance monitoring QC test was performed 3–4 times/week over a period of 10–11 months to monitor positional accuracy of individual leaves for two different MLC models. Analysis of test results was performed using individuals control charts per leaf with control limits computed based on the measurements as well as two sets of specifications of ±0.5 and ±1 mm. Out-of-specification and out-of-control leaves were automatically flagged by the monitoring system and reviewed monthly by physicists. MLC-related interlocks reported by the linear accelerator and servicing events were recorded to help identify potential causes of nonrandom MLC leaf positioning variations. Results: The precision of the MLC performance monitoring QC test and the MLC itself was within ±0.22 mm for most MLC leaves and the majority of the apparent leaf motion was attributed to beam spot displacements between irradiations. The MLC QC test was performed 193 and 162 times over the monitoring period for the studied units and recalibration had to be repeated up to three times on one of these units. For both units, rate of MLC interlocks was moderately associated with MLC servicing events. The strongest association with the MLC performance was observed between the MLC servicing events and the total number of out-of-control leaves. The average elapsed time for which the number of out-of-specification or out-of-control leaves was within a given performance threshold was computed and used to assess adequacy of MLC test frequency. Conclusions: A MLC performance monitoring system has been developed and implemented to acquire high-quality QC data at high frequency. This is enabled by the relatively short acquisition time for the images and automatic image analysis. The monitoring system was also used to record and track the rate of MLC-related interlocks and servicing events. MLC performances for two commercially available MLC models have been assessed and the results support monthly test frequency for widely accepted ±1 mm specifications. Higher QC test frequency is however required to maintain tighter specification and in-control behavior.

07 ISOTOPE AND RADIATION SOURCES↗

Precision Agriculture using Networks of Degradable Analytical Sensors (PANDAS) (Final Technical Report)

Precision agriculture, where sensing of soil, environment and crop conditions are used to precisely synchronize inputs (such as water and fertilizer) to crop needs enhances input use efficiency. This can improve yields and farm profitability while mitigating environmental losses, improving soil carbon content and substantially decreasing energy use for food, feed and fuel crops. Unfortunately, farmers are not yet able to harness the full potential of these management technologies as there is a lack of available management information, and there is therefore a need for sensors that are able to economically measure spatio-temporal variability in soil and crop properties of extremely heterogeneous farm fields precisely at high resolution and at low cost. Real-time, in-situ monitoring of agricultural soil conditions is today carried out using devices that limit the total number of nodes that can be used economically to typically one per acre or less. Higher spatio-temporal resolution sensing would enable more precise agricultural input optimization, with significant benefits to the farmer and the environment. In order to address this issue, this project focused on developing additively manufactured, biodegradable, soil sensors with predicted costs of < $\$$1 per unit to monitor crop inputs (such as water and fertilizer) that predictably, harmlessly degrade away into the soil when no longer needed. These sensor nodes should be easy to place, accurately and continuously monitor soil and crop conditions for an entire season, be read remotely using existing farm equipment, require no ongoing maintenance, not impede farm operations and produce no persistent waste. This approach could enable a >100× increase in information density over current solutions for precision farming of row and other crops, and lead to significant reductions in input energy use and provide increased yield for biofuel crops. Over the course of this project the team at the University of Colorado Boulder, University of California Berkeley, and Colorado State University/Kansas State University investigated a wide range of printable biodegradable electronic materials and sensor designs for determining soil moisture and soil nitrate concentration. These efforts expanded the available materials set for printed soil degradable electronic materials, particularly for conductors, enabling high conductivity and stability. Printed soil moisture and nitrate sensors with suitable sensitivity and selectivity were developed and characterized. Low power and passive wireless electronic systems were integrated with the soil sensors, and testing was carried out with completed sensors to understand their functionality under agricultural conditions. Additionally, other sensor types enabled by the biodegradable materials set created during this project, such as soil microbial activity sensors, were also developed and demonstrated. Project outputs include 10 peer reviewed publications, 4 patent applications, 21 technical presentations, 3 PhD thesis, 10 media reports, 8 additional grants worth over $\$$6M, and the formation of 3 start-up companies.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Nuclear fuel behavior at high temperature: new insights from post-test examinations on the VERDON-1 sample

In order to reduce the uncertainties concerning Source Term assessment under Light Water Reactor (LWR) severe accident conditions, 4 VERDON tests were recently performed. They have been defined in the framework of the International Source Term Program and carried out at CEA Cadarache, in the LECA-STAR facility. Among these 4 VERDON tests, VERDON-1 test was devoted to high burn-up UO{sub 2} fuel behavior and FP release under H{sub 2} reducing conditions at very high temperature. This test was performed with the Release Circuit, which is devoted to the precise characterization of the FP release, in terms of FP release kinetics and fission products (FPs) released fraction. The main components of the circuits are a furnace heating the fuel sample, a filter trapping the emitted aerosols and gamma spectrometry detectors for online and post-test measurements. VERDON-1 test was conducted up to about 2600 Celsius degrees without reaching global fuel relocation, allowing thereby post-test micro-analyses. After a brief description of the fuel sample nature and the experimental set-up, we present the progress of the experimental sequence and the associated gamma spectrometry measurements. We then focus on the major results of the VERDON-1 tests regarding the fuel global behavior. These results are obtained by two complementary techniques. First, the fuel sight gamma station can be used either on-line to detect fuel relocation or just after the test, as a longitudinal bench, to get preliminary information on the global shape of the fuel sample inside the furnace. Secondly, these information are completed by post-test examinations performed on the fuel sample after extraction from the furnace. Complete qualitative and quantitative characterizations, including EPMA (Electron Probe Micro-Analysis) and SEM (Scanning Electron Microscopy) analysis, were performed for the first time at the CEA Cadarache on a sample that has been submitted to such severe accident conditions. These results show an advanced state of sample degradation, with locally previously molten areas, meaning that fuel global relocation was imminent by the end of thermal-hydraulic sequence. The relocation temperature is compared to that of previous VERCORS tests and discussed regarding the atmosphere of the test and possible UO{sub 2}-ZrO{sub 2} interaction. (authors)

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Gallium oxide (Ga2O3) as a radiation detector distinguishing neutrons and gammas

Gallium oxide (Ga2O3) is a promising ultrawide bandgap semiconductor for radiation detection with the potential of integrating electronic and scintillation functions within a single crystal device. This study establishes the scintillation response of β-Ga2O3 gamma irradiation from yttrium-88 (88Y). Then, californium-252 (252Cf) is used as a spontaneous fission source of mixed neutron and gamma radiation field to measure scintillation signals. Pulse shape discrimination and constant fraction discrimination techniques were used to separate neutron and gamma interaction events. Further investigation indicates that the prompt temporal responses of β-Ga2O3 for gammas and neutrons may enable discrimination of the two by prompt pulse fitting methods, focused around the initial peak. For gamma irradiation, we observed a rise time (τr) of 2.1 ns, decay time (τd) of 9.5 ns, and a full width at half maximum (FWHM) of 6.2 ns. For neutrons, it showed a τr of 2.3 ns, a τd of 12.1 ns, 9.4 ns FWHM, and reduced peak intensity. A diamond detector exhibited a more symmetrical τr and τd for both gamma and neutron signals and therefore is less effective at discriminating between the two by this method. This draws attention to β-Ga2O3’s ability to distinguish neutron and gamma particles. These findings showcase Ga2O3’s potential as a next-generation semiconductor for applications in nuclear safety and medical imaging, where precise discrimination between neutron and gamma interactions is essential.

Valdes, D. J. (ORCID:0000000304373720)↗

Damping Ring R&D at CESR-TA

Accelerators that collide high energy beams of matter and anti-matter are essential tools for the investigation of the fundamental constituents of matter, and the search for new forms of matter and energy. A “Linear Collider” is a machine that would bring high energy and very compact bunches of electrons and positrons (anti-electrons) into head-on collision. Such a machine would produce (among many other things) the newly discovered Higgs particle, enabling a detailed study of its properties. Among the most critical and challenging components of a linear collider are the damping rings that produce the very compact and intense beams of electrons and positrons that are to be accelerated into collision. Hot dilute particle beams are injected into the damping rings, where they are compressed and cooled. The size of the positron beam must be reduced more than a thousand fold in the damping ring, and this compression must be accomplished in a fraction of a second. The cold compact beams are then extracted from the damping ring and accelerated into collision at high energy. The proposed International Linear Collider (ILC), would require damping rings that routinely produce such cold, compact and intense beams. The goal of the Cornell study was a credible design for the damping rings for the ILC. Among the technical challenges of the damping rings; the development of instrumentation that can measure the properties of the very small beams in a very narrow window of time, and mitigation of the forces that can destabilize the beams and prevent adequate cooling, or worse lead to beam loss. One of the most pernicious destabilizing forces is due to the formation of clouds of electrons in the beam pipe. The electron cloud effect is a phenomenon in particle accelerators in which a high density of low energy electrons, build up inside the vacuum chamber. At the outset of the study, it was anticipated that electron cloud effects would limit the intensity of the positron ring, and that an instability associated with residual gas in the beam pipe would limit the intensity of the electron ring. It was also not clear whether the required very small beam size could be achieved. The results of this study are important contributions to the design of both the electron and positron damping rings in which all of those challenges are addressed and overcome. Our findings are documented in the ILC Technical Design Report, a document that represents the work of an international collaboration of scientists. Our contributions include design of the beam magnetic optics for the 3 km circumference damping rings, the vacuum system and surface treatments for electron cloud mitigation, the design of the guide field magnets, design of the superconducting damping wigglers, and new detectors for precision measurement of beam properties. Our study informed the specification of the basic design parameters for the damping rings, including alignment tolerances, magnetic field errors, and instrumentation. We developed electron cloud modelling tools and simulations to aid in the interpretation of the measurements that we carried out in the Cornell Electron-positron Storage Ring (CESR). The simulations provide a means for systematic extrapolation of our measurements at CESR to the proposed ILC damping rings, and ultimately to specify how the beam pipes should be fabricated in order to minimize the effects of the electron cloud. With the conclusion of this study, the design of the essential components of the damping rings is complete, including the development and characterization (with computer simulations) of the beam optics, specification of techniques for minimizing beam size, design of damping ring instrumentation, R&D into electron cloud suppression methods, tests of long term durability of electron cloud coatings, and design of damping ring vacuum system components.

43 PARTICLE ACCELERATORS↗

Improved Fireset Acceptance Using Established Evaluation Measurements

As new insight is gained into the relationship between firesets and detonators, tighter control of the circuit parameters is desired to maintain consistent and optimum system performance. An analysis of the established acceptance method reveals that it has insufficient precision to guarantee a uniform population of units. While the production has been historically very uniform, the uniformity has been primarily due to the quality and consistency of the manufacturing process rather than to the stringency of the acceptance criteria. The established method of evaluating and accepting firesets for the stockpile has been to discharge the units into a representative load and to record the output current waveform. Three characteristics of the output waveform (Peak Current, Rise Time, and Pulse Width) are then analyzed and an acceptance window is applied directly to these measurements. The purpose of this paper is to introduce a new approach that incorporates these same established measurements. However, instead of applying acceptance criteria to the three measurements directly, rather these measurements are used to evaluate the circuit values of capacitance, inductance and resistance to provide a more stringent and uniform acceptance criteria.

42 ENGINEERING↗