Search NASA⌕ Search

SEARCH · Search NASA

Results for “RADIATION DOSES”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 721 records · Page 40

Poster — Thur Eve — 42: Radiochromic film calibration for low-energy seed brachytherapy dose measurement

The purpose of this study was to investigate the accuracy of radiochromic film calibration procedures used in external beam radiotherapy when applied to I-125 brachytherapy sources delivering higher doses, and to determine any necessary modifications to achieve similar accuracy in absolute dose measurements. GafChromic EBT3 film was used to measure radiation doses upwards of 35 Gy from 6 MV, 75 kVp and (∼28 keV) I-125 photon sources. A custom phantom was used for the I-125 irradiations to obtain a larger film area with nearly constant dose to reduce the effects of film heterogeneities on the optical density (OD) measurements. RGB transmission images were obtained with an Epson 10000XL flatbed scanner, and calibration curves relating OD and dose using a rational function were determined for each colour channel and at each energy using a non-linear least square minimization method. Differences found between the 6 MV calibration curve and those for the lower energy sources are large enough that 6 MV beams should not be used to calibrate film for low-energy sources. However, differences between the 75 kVp and I-125 calibration curves were quite small; indicating that 75 kVp is a good choice. Compared with I-125 irradiation, this gives the advantages of lower type B uncertainties and markedly reduced irradiation time. To obtain high accuracy calibration for the dose range up to 35 Gy, two-segment piece-wise fitting was required. This yielded absolute dose measurement accuracy above 1 Gy of ∼2% for 75 kVp and ∼5% for I-125 seed exposures.

60 APPLIED LIFE SCIENCES↗

Assessment of tumor response to radiation and vascular targeting therapy in mice using quantitative ultrasound spectroscopy

Purpose: It is now recognized that the tumor vasculature is in part responsible for regulating tumor responses to radiation therapy. However, the extent to which radiation-based vascular damage contributes to tumor cell death remains unknown. In this work, quantitative ultrasound spectroscopy (QUS) methods were used to investigate the acute responses of tumors to radiation-based vascular treatments. Methods: Tumor xenografts (MDA-MB-231) were treated with single radiation doses of 2 or 8 Gy alone, or in combination with pharmacological agents that modulate vascular radiosensitivity. The midband fit, the slope, and the 0-MHz intercept QUS parameters were obtained from a linear-regression fit to the averaged power spectrum of frequency-dependent ultrasound backscatter and were used to quantify acute tumor responses following treatment administration. Power spectrums were extracted from raw volumetric radio-frequency ultrasound data obtained before and 24 h following treatment administration. These parameters have previously been correlated to tumor cell death. Staining using in situ end labeling, carbonic anhydrase 9 and cluster of differentiation 31 of tumor sections were used to assess cell death, oxygenation, and vasculature distributions, respectively. Results: Results indicate a significant midband fit QUS parameter increases of 3.2 ± 0.3 dBr and 5.4 ± 0.5 dBr for tumors treated with 2 and 8 Gy radiation combined with the antiangiogenic agent Sunitinib, respectively. In contrast, tumors treated with radiation alone demonstrated a significant midband fit increase of 4.4 ± 0.3 dBr at 8 Gy only. Preadministration of basic fibroblast growth factor, an endothelial radioprotector, acted to minimize tumor response following single large doses of radiation. Immunohistochemical analysis was in general agreement with QUS findings; an R{sup 2} of 0.9 was observed when quantified cell death was correlated with changes in midband fit. Conclusions: Results from QUS analysis presented in this study confirm that acute tumor response is linked to a vascular effect following high doses of radiation therapy. Overall, this is in agreement with previous reports suggesting that acute tumor radiation response is regulated by a vascular-driven response. Data also suggest that Sunitinib may enhance tumor radiosensitivity through a vascular remodeling process, and that QUS may be sensitive to changes in tissue properties associated with vascular remodeling. Finally, the work also demonstrates the ability of QUS methods to monitor response to radiation-based vascular strategies.

60 APPLIED LIFE SCIENCES↗

Development and Preliminary Evaluation of a Murine Model of Chronic Radiation-Induced Proctitis

Radiotherapy (RT) is commonly used to treat most pelvic malignancies. While treatment is often effective, curative radiation doses to the rectum can result in chronic radiation-induced proctitis, which is characterized by diarrhea, tenesmus, and/or rectal bleeding, recently termed pelvic radiation disease. An animal model of chronic radiation-induced proctitis would be useful to test both preventative and therapeutic strategies to limit this morbidity but has been elusive because of the high rodent mortality associated with acute bowel RT injury. The objective of this research was to develop a novel mouse model of chronic radiation-induced proctitis using advanced technology.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

An interprojection sensor fusion approach to estimate blocked projection signal in synchronized moving grid-based CBCT system

Purpose: A preobject grid can reduce and correct scatter in cone beam computed tomography (CBCT). However, half of the signal in each projection is blocked by the grid. A synchronized moving grid (SMOG) has been proposed to acquire two complimentary projections at each gantry position and merge them into one complete projection. That approach, however, suffers from increased scanning time and the technical difficulty of accurately merging the two projections per gantry angle. Herein, the authors present a new SMOG approach which acquires a single projection per gantry angle, with complimentary grid patterns for any two adjacent projections, and use an interprojection sensor fusion (IPSF) technique to estimate the blocked signal in each projection. The method may have the additional benefit of reduced imaging dose due to the grid blocking half of the incident radiation. Methods: The IPSF considers multiple paired observations from two adjacent gantry angles as approximations of the blocked signal and uses a weighted least square regression of these observations to finally determine the blocked signal. The method was first tested with a simulated SMOG on a head phantom. The signal to noise ratio (SNR), which represents the difference of the recovered CBCT image to the original image without the SMOG, was used to evaluate the ability of the IPSF in recovering the missing signal. The IPSF approach was then tested using a Catphan phantom on a prototype SMOG assembly installed in a bench top CBCT system. Results: In the simulated SMOG experiment, the SNRs were increased from 15.1 and 12.7 dB to 35.6 and 28.9 dB comparing with a conventional interpolation method (inpainting method) for a projection and the reconstructed 3D image, respectively, suggesting that IPSF successfully recovered most of blocked signal. In the prototype SMOG experiment, the authors have successfully reconstructed a CBCT image using the IPSF-SMOG approach. The detailed geometric features in the Catphan phantom were mostly recovered according to visual evaluation. The scatter related artifacts, such as cupping artifacts, were almost completely removed. Conclusions: The IPSF-SMOG is promising in reducing scatter artifacts and improving image quality while reducing radiation dose.

61 RADIATION PROTECTION AND DOSIMETRY↗

Practical dose point-based methods to characterize dose distribution in a stationary elliptical body phantom for a cone-beam C-arm CT system

Purpose: To propose new dose point measurement-based metrics to characterize the dose distributions and the mean dose from a single partial rotation of an automatic exposure control-enabled, C-arm-based, wide cone angle computed tomography system over a stationary, large, body-shaped phantom. Methods: A small 0.6 cm{sup 3} ion chamber (IC) was used to measure the radiation dose in an elliptical body-shaped phantom made of tissue-equivalent material. The IC was placed at 23 well-distributed holes in the central and peripheral regions of the phantom and dose was recorded for six acquisition protocols with different combinations of minimum kVp (109 and 125 kVp) and z-collimator aperture (full: 22.2 cm; medium: 14.0 cm; small: 8.4 cm). Monte Carlo (MC) simulations were carried out to generate complete 2D dose distributions in the central plane (z = 0). The MC model was validated at the 23 dose points against IC experimental data. The planar dose distributions were then estimated using subsets of the point dose measurements using two proposed methods: (1) the proximity-based weighting method (method 1) and (2) the dose point surface fitting method (method 2). Twenty-eight different dose point distributions with six different point number cases (4, 5, 6, 7, 14, and 23 dose points) were evaluated to determine the optimal number of dose points and their placement in the phantom. The performances of the methods were determined by comparing their results with those of the validated MC simulations. The performances of the methods in the presence of measurement uncertainties were evaluated. Results: The 5-, 6-, and 7-point cases had differences below 2%, ranging from 1.0% to 1.7% for both methods, which is a performance comparable to that of the methods with a relatively large number of points, i.e., the 14- and 23-point cases. However, with the 4-point case, the performances of the two methods decreased sharply. Among the 4-, 5-, 6-, and 7-point cases, the 7-point case (1.0% [±0.6%] difference) and the 6-point case (0.7% [±0.6%] difference) performed best for method 1 and method 2, respectively. Moreover, method 2 demonstrated high-fidelity surface reconstruction with as few as 5 points, showing pixelwise absolute differences of 3.80 mGy (±0.32 mGy). Although the performance was shown to be sensitive to the phantom displacement from the isocenter, the performance changed by less than 2% for shifts up to 2 cm in the x- and y-axes in the central phantom plane. Conclusions: With as few as five points, method 1 and method 2 were able to compute the mean dose with reasonable accuracy, demonstrating differences of 1.7% (±1.2%) and 1.3% (±1.0%), respectively. A larger number of points do not necessarily guarantee better performance of the methods; optimal choice of point placement is necessary. The performance of the methods is sensitive to the alignment of the center of the body phantom relative to the isocenter. In body applications where dose distributions are important, method 2 is a better choice than method 1, as it reconstructs the dose surface with high fidelity, using as few as five points.

60 APPLIED LIFE SCIENCES↗

MO-G-BRF-09: Investigating Magnetic Field Dose Effects in Mice: A Monte Carlo Study

Purpose: In MRI-linac treatments, radiation dose distributions are affected by magnetic fields, especially at high-density/low-density interfaces. Radiobiological consequences of magnetic field dose effects are presently unknown; therefore, preclinical studies are needed to ensure the safe clinical use of MRI-linacs. This study investigates the optimal combination of beam energy and magnetic field strength needed for preclinical murine studies. Methods: The Monte Carlo code MCNP6 was used to simulate the effects of a magnetic field when irradiating a mouse-sized lung phantom with a 1.0cmx1.0cm photon beam. Magnetic field effects were examined using various beam energies (225kVp, 662keV[Cs-137], and 1.25MeV[Co-60]) and magnetic field strengths (0.75T, 1.5T, and 3T). The resulting dose distributions were compared to Monte Carlo results for humans with various field sizes and patient geometries using a 6MV/1.5T MRI-linac. Results: In human simulations, the addition of a 1.5T magnetic field caused an average dose increase of 49% (range:36%–60%) to lung at the soft tissue-to-lung interface and an average dose decrease of 30% (range:25%–36%) at the lung-to-soft tissue interface. In mouse simulations, the magnetic fields had no effect on the 225kVp dose distribution. The dose increases for the Cs-137 beam were 12%, 33%, and 49% for 0.75T, 1.5T, and 3.0T magnetic fields, respectively while the dose decreases were 7%, 23%, and 33%. For the Co-60 beam, the dose increases were 14%, 45%, and 41%, and the dose decreases were 18%, 35%, and 35%. Conclusion: The magnetic field dose effects observed in mouse phantoms using a Co-60 beam with 1.5T or 3T fields and a Cs-137 beam with a 3T field compare well with those seen in simulated human treatments with an MRI-linac. These irradiator/magnet combinations are suitable for preclinical studies investigating potential biological effects of delivering radiation therapy in the presence of a magnetic field. Partially funded by Elekta.

60 APPLIED LIFE SCIENCES↗

SU-F-P-29: Impact of Oral Contrast Agent for Assisting in Outlining Small Intestine On Pelvic IMAT Dose in Patients with Cervical Cancer

Purpose: As the advanced intensity modulated arc therapy(IMAT) delivery systems becoming a main role of treatment ways, which places even greater demands on delivering accuracy. The impact of oral contrast agent (meglumine diatrizoate) for assisting in outlining the small intestine on pelvic IMAT dose in patients with cervical cancer was investigated. Methods: Ten cervical cancer patients for postoperative radiotherapy underwent CT scans, and the planning target volumes (PTV) and organs at risk (including the small intestine, rectum, bladder, colon and the left and right femoral head) were contoured. The IMAT plans were generated on Oncentra v4.1 planning system for each case, PTV was prescribed to 50.4 Gy in 28 fractions. Then another plan was generated by re-calculating the radiation dose after changing the electron density of the small bowel. The first plan (plan A) was the conventional IMAT plan (with oral contrast agent), and the second one (plan B) specified the electron density of the small bowel (without oral contrast agent). Paired t-test was used to compare the dose distribution between the two plans. Results: The PTV’s D2, D50, D95, V110, conformity index, and homogeneity index of plans A and B were 5610.5 vs. 5611.4 cGy (P=0.175), 5348.5 vs. 5348.0 cGy (P=0.869), 5039 vs. 5042.3 (P=0.518), 6.0% vs. 6.1 %( P=0.886), 0.1269 vs. 0.1271 (P=0.34) and 0.8421 vs. 0.8416 (P=0.598), respectively. The volumes of the small bowel receiving at least 30 Gy (V30) and the minimum dose of 2% volume accepted (D2) for plans A and B were 31.6% vs. 31.9% (P=0.371) and 5067.8 vs. 5085.4 cGy (P=0.377), while rectum V50 of the two plans was 12.4% vs. 12.1% (P=0.489). Conclusion: The oral contrast agent (meglumine diatrizoate) filling the small intestine does not lead to a significant increase in the pelvic IMAT dose in patients with cervical cancer.

60 APPLIED LIFE SCIENCES↗

Effects of ionising radiation exposure in offspring and next generations: dosimetric aspects and uncertainties

The impact of the exposure to ionizing radiation in the offspring and next generation has been investigated in the last decades and currently is the subject of study of the ICRP Task Group 121. Studying the effects of radiation exposure in pre-conceptional and post-conceptional phases can be a challenge since potential effects to the fetus vary depending on the stage of fetal development. Epidemiology and radiobiology studies are the two sources of information one can use to correlate the radiation dose to the human body and tissues and the resulting effects. For a proper evaluation of the outcomes of such studies, and a correct appraisal of the exposure/dose-effect relationship, (i) reliable dosimetry, (ii) accurate reporting, and (iii) reproducibility of results are required. Although variables related to dose, including for instance source of radiation, geometry of irradiation, dose rate etc., are usually known, especially in radiobiology studies, often important details of the irradiation are not reported. In conclusion, based on standards developed by the National Cancer Institute (NCI), the National Institute of Allergy and Infectious Disease (NIAID) and the National Institute of Standards and Technology (NIST), a review of the scientific studies used by the UNSCEAR to estimate the risk of hereditary effects, and by the ICRP in its current recommendations, was conducted to evaluate the way dosimetry was reported. Dosimetry and the related uncertainties were not adequately described in the vast majority of those studies. This does not necessarily mean that they do not provide relevant information, however it prevents from a thorough verification and reproduction of their findings. In order to guarantee the reliability and robustness of the process of revision of the estimates of risk and detriment it is therefore considered mandatory to include a careful check of the new relevant literature with regard to the criteria on the completeness and reproducibility of the dosimetric information.

63 RADIATION, THERMAL, AND OTHER ENVIRON. POLLUTAN↗

Poster — Thur Eve — 10: Partial kV CBCT, complete kV CBCT and EPID in breast treatment: a dose comparison study for skin, breasts, heart and lungs

The advantages of kilovoltage cone beam CT (kV CBCT) imaging over electronic portal imaging device (EPID) such as accurate 3D anatomy, soft tissue visualization, fast rigid registration and enhanced precision on patient positioning has lead to its increasing use in clinics. The benefits of this imaging technique are at the cost of increasing the dose to healthy surrounding organs. Our center has moved toward the use of daily partial rotation kV CBCT to restrict the dose to healthy tissues. This study aims to better quantify radiation doses from different image-guidance techniques such as tangential EPID, complete and partial kV CBCT for breast treatments. Cross-calibrated ionization chambers and kV calibrated Gafchromic films were used to measure the dose to the heart, lungs, breasts and skin. It was found that performing partial kV CBCT decreases the heart dose by about 36%, the lungs dose by 31%, the contralateral breast dose by 41% and the ipsilateral breast dose by 43% when compared to a full rotation CBCT. The skin dose measured for a full rotation CBCT was about 0.8 cGy for the contralateral breast and about 0.3 cGy for the ipsilateral breast. The study is still ongoing and results on skin doses for partial rotation kV CBCT as well as for tangential EPID images are upcoming.

60 APPLIED LIFE SCIENCES↗

Radiochromic film calibration for low-energy seed brachytherapy dose measurement

Purpose: Radiochromic film dosimetry is typically performed for high energy photons and moderate doses characterizing external beam radiotherapy (XRT). The purpose of this study was to investigate the accuracy of previously established film calibration procedures used in XRT when applied to low-energy, seed-based brachytherapy at higher doses, and to determine necessary modifications to achieve similar accuracy in absolute dose measurements. Methods: Gafchromic EBT3 film was used to measure radiation doses upwards of 35 Gy from 75 kVp, 200 kVp, 6 MV, and (∼28 keV) I-125 photon sources. For the latter irradiations a custom phantom was built to hold a single I-125 seed. Film pieces were scanned with an Epson 10000XL flatbed scanner and the resulting 48-bit RGB TIFF images were analyzed using both FilmQA Pro software andMATLAB. Calibration curves relating dose and optical density via a rational functional form for all three color channels at each irradiation energy were determined with and without the inclusion of uncertainties in the measured optical densities and dose values. The accuracy of calibration curve variations obtained using piecewise fitting, a reduced film measurement area for I-125 irradiation, and a reduced number of dose levels was also investigated. The energy dependence of the film lot used was also analyzed by calculating normalized optical density values. Results: Slight differences were found in the resulting calibration curves for the various fitting methods used. The accuracy of the calibration curves was found to improve at low doses and worsen at high doses when including uncertainties in optical densities and doses, which may better represent the variability that could be seen in film optical density measurements. When exposing the films to doses > 8 Gy, two-segment piecewise fitting was found to be necessary to achieve similar accuracies in absolute dose measurements as when using smaller dose ranges. When reducing the film measurement area for the I-125 irradiations, the accuracy of the calibration curve was degraded due to the presence of localized film heterogeneities. No degradation in the calibration curves was found when reducing the number of calibration points down to only 4, but with piecewise fitting, 6 calibration points as well as a blank film are required. Variations due to photon energy in film optical density of up to 3% were found above doses of 2 Gy. Conclusions: A modified procedure for performing EBT3 film calibration was established for use with low-energy brachytherapy seeds and high dose exposures. The energy dependence between 6 MV and I-125 photons is significant such that film calibrations should be done with an appropriately low-energy source when performing low-energy brachytherapy dose measurements. Two-segment piecewise fitting with the inclusion of errors in measured optical density as well as dose was found to result in the most accurate calibration curves. Above doses of 1 Gy, absolute dose measurements can be made with an accuracy of 1.6% for 6 MV beams and 5.7% for I-125 seed exposures if using the I-125 source for calibration, or 2.3% if using the 75 kVp photon beam for calibration.

07 ISOTOPE AND RADIATION SOURCES↗

Computed Tomography Number Changes Observed During Computed Tomography–Guided Radiation Therapy for Head and Neck Cancer

Purpose: To investigate CT number (CTN) changes in gross tumor volume (GTV) and organ at risk (OAR) according to daily diagnostic-quality CT acquired during CT-guided intensity modulated radiation therapy for head and neck cancer (HNC) patients. Methods and Materials: Computed tomography scans acquired using a CT-on-rails during daily CT-guided intensity modulated radiation therapy for 15 patients with stage II to IVa squamous cell carcinoma of the head and neck were analyzed. The GTV, parotid glands, spinal cord, and nonspecified tissue were generated on each selected daily CT. The changes in CTN distributions and the mean and mode values were collected. Pearson analysis was used to assess the correlation between the CTN change, organ volume reduction, and delivered radiation dose. Results: Volume and CTN changes for GTV and parotid glands can be observed during radiation therapy delivery for HNC. The mean (±SD) CTNs in GTV and ipsi- and contralateral parotid glands were reduced by 6 ± 10, 8 ± 7, and 11 ± 10 Hounsfield units, respectively, for all patients studied. The mean CTN changes in both spinal cord and nonspecified tissue were almost invisible (<2 Hounsfield units). For 2 patients studied, the absolute mean CTN changes in GTV and parotid glands were strongly correlated with the dose delivered (P<.001 and P<.05, respectively). For the correlation between CTN reductions and delivered isodose bins for parotid glands, the Pearson coefficient varied from −0.98 (P<.001) in regions with low-dose bins to 0.96 (P<.001) in high-dose bins and were patient specific. Conclusions: The CTN can be reduced in tumor and parotid glands during the course of radiation therapy for HNC. There was a fair correlation between CTN reduction and radiation doses for a subset of patients, whereas the correlation between CTN reductions and volume reductions in GTV and parotid glands were weak. More studies are needed to understand the mechanism for the radiation-induced CTN changes.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

TH-CD-201-03: A Real-Time Method to Simultaneously Measure Linear Energy Transfer and Dose for Proton Therapy Using Organic Scintillators

Purpose: The light generated in organic scintillators depends on both the radiation dose and the linear energy transfer (LET). The LET dependence leads to an under-response of the detector in the Bragg peak of proton beams. This phenomenon, called ionization quenching, must be corrected to obtain accurate dose measurements of proton beams. This work exploits the ionization quenching phenomenon to provide a method of measuring LET and auto correcting quenching. Methods: We exposed simultaneously four different organic scintillators (BCF-12, PMMA, PVT, and LSD; 1mm in diameter) and a plane parallel ionization chamber in passively scattered proton beams to doses between 32 and 43 cGy and fluence averaged LET values from 0.47 to 1.26 keV/µm. The LET values for each irradiation condition were determined using a validated Monte Carlo model of the beam line. We determined the quenching parameter in the Birk’s equation for scintillation in BCF-12 for dose measurements. One set of irradiation conditions was used to correlate the scintillation response ratio to the LET values and plot a scintillation response ratio versus LET calibration curve. Irradiation conditions independent from the calibration ones were used to validate this method. Comparisons to the expected values were made on both the basis of dose and LET. Results: Among all the scintillators investigated, the ratio of PMMA to BCF-12 provided the best correlation to LET values and was used as the LET calibration curve. The expected LET values in the validation set were within 2%±6%, which resulted in dose accuracy of 1.5%±5.8% for the range of LET values investigated in this work. Conclusion: We have demonstrated the feasibility of using the ratio between the light output of two organic scintillators to simultaneously measure LET and dose of therapeutic proton beams. Further studies are needed to verify the response in higher LET values.

60 APPLIED LIFE SCIENCES↗

Stochastic Modeling of Radioactive Material Releases

Nonreactor nuclear facilities operated under the approval authority of the U.S. Department of Energy use unmitigated hazard evaluations to determine if potential radiological doses associated with design basis events challenge or exceed dose evaluation guidelines. Unmitigated design basis events that sufficiently challenge dose evaluation guidelines or exceed the guidelines for members of the public or workers, merit selection of safety structures, systems, or components or other controls to prevent or mitigate the hazard. Idaho State University, in collaboration with Idaho National Laboratory, has developed a portable and simple to use software application called SODA (Stochastic Objective Decision-Aide) that stochastically calculates the radiation dose associated with hypothetical radiological material release scenarios. Rather than producing a point estimate of the dose, SODA produces a dose distribution result to allow a deeper understanding of the dose potential. SODA allows users to select the distribution type and parameter values for all of the input variables used to perform the dose calculation. SODA then randomly samples each distribution input variable and calculates the overall resulting dose distribution. In cases where an input variable distribution is unknown, a traditional single point value can be used. SODA was developed using the MATLAB coding framework. The software application has a graphical user input. SODA can be installed on both Windows and Mac computers and does not require MATLAB to function. SODA provides improved risk understanding leading to better informed decision making associated with establishing nuclear facility material-at-risk limits and safety structure, system, or component selection. It is important to note that SODA does not replace or compete with codes such as MACCS or RSAC, rather it is viewed as an easy to use supplemental tool to help improve risk understanding and support better informed decisions. The work was funded through a grant from the DOE Nuclear Safety Research and Development Program.

61 RADIATION PROTECTION AND DOSIMETRY↗

Dose Rate Analysis of As-Loaded Spent Nuclear Fuel Casks - Paper 97

Used Nuclear Fuel Storage, Transportation and Disposal Analysis Resource and Data System (UNF-ST[and]DARDS) is a comprehensive data and calculation capability for UNF safety assessments currently being developed at Oak Ridge National Laboratory through a collaborative effort of multiple national laboratories and industry participants. The purpose of UNF-ST[and]DARDS is to provide a unified domestic UNF system of data and analysis capabilities in support of U.S. Department of Energy waste management and fuel cycle-related objectives. UNF-ST[and]DARDS is designed to provide safety assessments for UNF storage, transportation, and disposal systems based on actual characteristics of the as-loaded UNF (e.g., fuel assembly burnup, enrichment, decay time, cladding integrity, etc.). The cask-specific safety evaluations allow quantification of realistic safety margins and conditions and provide the technical basis for addressing concerns related to potential fuel failure (e.g., for high-burnup fuel). This paper describes the UNF-ST[and]DARDS methodology for calculating radiation dose rates for U.S. Nuclear Regulatory Commission (NRC) licensed casks based on actual UNF canister contents. Realistic dose rate values based on actual canister contents may be used in place of bounding dose rate values to support development of repackaging operations procedures, evaluation of radiation-related transportation risks, and communication with stakeholders. UNF-ST[and]DARDS capabilities have been recently expanded to include automated radiation source term calculations and dose rate analyses of as-loaded transportation casks. This unique capability determines realistic dose rate values based on actual canister UNF contents that may be used in radiation dose assessments to demonstrate safe transportation of commercial UNF. (authors)

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Data and methods to estimate fetal dose from fluoroscopically guided prophylactic hypogastric artery balloon occlusion

Purpose: To provide data for estimation of fetal radiation dose (D{sub F}) from prophylactic hypogastric artery balloon occlusion (HABO) procedures. Methods: The Monte-Carlo-N-particle (MCNP) transport code and mathematical phantoms representing a pregnant patient at the ninth month of gestation were employed. PA, RAO 20° and LAO 20° fluoroscopy projections of left and right internal iliac arteries were simulated. Projection-specific normalized fetal dose (NFD) data were produced for various beam qualities. The effects of projection angle, x-ray field location relative to the fetus, field size, maternal body size, and fetal size on NFD were investigated. Presented NFD values were compared to corresponding values derived using a physical anthropomorphic phantom simulating pregnancy at the third trimester and thermoluminescence dosimeters. Results: NFD did not considerably vary when projection angle was altered by ±5°, whereas it was found to markedly depend on tube voltage, filtration, x-ray field location and size, and maternal body size. Differences in NFD < 7.5% were observed for naturally expected variations in fetal size. A difference of less than 13.5% was observed between NFD values estimated by MCNP and direct measurements. Conclusions: Data and methods provided allow for reliable estimation of radiation burden to the fetus from HABO.

60 APPLIED LIFE SCIENCES↗

Spectrotemporal CT data acquisition and reconstruction at low dose

Purpose: X-ray computed tomography (CT) is widely used, both clinically and preclinically, for fast, high-resolution anatomic imaging; however, compelling opportunities exist to expand its use in functional imaging applications. For instance, spectral information combined with nanoparticle contrast agents enables quantification of tissue perfusion levels, while temporal information details cardiac and respiratory dynamics. The authors propose and demonstrate a projection acquisition and reconstruction strategy for 5D CT (3D + dual energy + time) which recovers spectral and temporal information without substantially increasing radiation dose or sampling time relative to anatomic imaging protocols. Methods: The authors approach the 5D reconstruction problem within the framework of low-rank and sparse matrix decomposition. Unlike previous work on rank-sparsity constrained CT reconstruction, the authors establish an explicit rank-sparse signal model to describe the spectral and temporal dimensions. The spectral dimension is represented as a well-sampled time and energy averaged image plus regularly undersampled principal components describing the spectral contrast. The temporal dimension is represented as the same time and energy averaged reconstruction plus contiguous, spatially sparse, and irregularly sampled temporal contrast images. Using a nonlinear, image domain filtration approach, the authors refer to as rank-sparse kernel regression, the authors transfer image structure from the well-sampled time and energy averaged reconstruction to the spectral and temporal contrast images. This regularization strategy strictly constrains the reconstruction problem while approximately separating the temporal and spectral dimensions. Separability results in a highly compressed representation for the 5D data in which projections are shared between the temporal and spectral reconstruction subproblems, enabling substantial undersampling. The authors solved the 5D reconstruction problem using the split Bregman method and GPU-based implementations of backprojection, reprojection, and kernel regression. Using a preclinical mouse model, the authors apply the proposed algorithm to study myocardial injury following radiation treatment of breast cancer. Results: Quantitative 5D simulations are performed using the MOBY mouse phantom. Twenty data sets (ten cardiac phases, two energies) are reconstructed with 88 μm, isotropic voxels from 450 total projections acquired over a single 360° rotation. In vivo 5D myocardial injury data sets acquired in two mice injected with gold and iodine nanoparticles are also reconstructed with 20 data sets per mouse using the same acquisition parameters (dose: ∼60 mGy). For both the simulations and the in vivo data, the reconstruction quality is sufficient to perform material decomposition into gold and iodine maps to localize the extent of myocardial injury (gold accumulation) and to measure cardiac functional metrics (vascular iodine). Their 5D CT imaging protocol represents a 95% reduction in radiation dose per cardiac phase and energy and a 40-fold decrease in projection sampling time relative to their standard imaging protocol. Conclusions: Their 5D CT data acquisition and reconstruction protocol efficiently exploits the rank-sparse nature of spectral and temporal CT data to provide high-fidelity reconstruction results without increased radiation dose or sampling time.

60 APPLIED LIFE SCIENCES↗