Search NASA⌕ Search

SEARCH · Search NASA

Results for “Strontium”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 721 records · Page 40

Modeling Electrokinetics of Oxygen Electrodes in Solid Oxide Electrolyzer Cells

A microscale model is presented in this study to simulate electrode kinetics of the oxygen electrode in a solid oxide electrolyzer cell (SOEC). Two mixed ionic/electronic conducting structures are examined for the oxygen producing electrode in this work: single layer porous lanthanum strontium cobalt ferrite (LSCF), and bilayer LSCF/SCT (strontium cobalt tantalum oxide) structures. A yttrium-stabilized zirconia (YSZ) electrolyte separates the hydrogen and oxygen electrodes, as well as a gadolinium doped-ceria (GDC) buffer layer on the oxygen electrode side. Electrochemical reactions occurring at the two-phase boundaries (2PBs) and three-phase boundaries (3PBs) of single-layer LSCF and bilayer LSCF/SCT oxygen electrodes are modeled under various SOEC voltages with lattice oxygen stoichiometry as the key output. The results reveal that there exists a competition in electrode kinetics between 2PBs and 3PBs, but 3PBs are the primary reactive sites for single-layer LSCF oxygen electrode under high voltages. These locations experience the greatest oxygen stoichiometry variations and are therefore the most likely locations for dimensional changes. By applying an active SCT layer over LSCF, the 2PBs become activated to compete with the 3PBs, thus alleviating oxygen stoichiometry variations and reducing the likelihood of dimensional change. This strategy could reduce lattice structural expansion, proving to be valuable for electrode-electrolyte delamination prevention and will be the focus of future work.

30 DIRECT ENERGY CONVERSION↗

PILOT-SCALE TESTING OF THE SUSPENSION OF MST, CST, AND SIMULATED SLUDGE SLURRIES IN A SLUDGE TANK

The Small Column Ion Exchange (SCIX) process is being developed to remove cesium, strontium, and actinides from Savannah River Site (SRS) Liquid Waste using an existing waste tank (i.e., Tank 41H) to house the process. Following strontium, actinide, and cesium removal, the concentrated solids will be transported to a sludge tank (i.e., monosodium titanate (MST)/sludge solids to Tank 42H or Tank 51H and crystalline silicotitanate (CST) to Tank 40H) for eventual transfer to the Defense Waste Processing Facility (DWPF). Savannah River National Laboratory (SRNL) is conducting pilot-scale mixing tests to determine the pump requirements for mixing MST, CST, and simulated sludge. The purpose of this pilot scale testing is to determine the pump requirements for mixing MST and CST with sludge in a sludge tank and to determine whether segregation of particles occurs during settling. Tank 40H and Tank 51H have four Quad Volute pumps; Tank 42H has four standard pumps. The pilot-scale tank is a 1/10.85 linear scaled model of Tank 40H. The tank diameter, tank liquid level, pump nozzle diameter, pump elevation, and cooling coil diameter are all 1/10.85 of their dimensions in Tank 40H. The pump locations correspond to the current locations in Tank 40H (Risers B2, H, B6, and G). The pumps are pilot-scale Quad Volute pumps. Additional settling tests were conducted in a 30 foot tall, 4 inch inner diameter clear column to investigate segregation of MST, CST, and simulated sludge particles during settling.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Scaling solid resuspension and sorption for the small column ion exchange processing tank

The Small Column Ion Exchange (SCIX) process is being developed to remove cesium, strontium, and actinides from Savannah River Site (SRS) Liquid Waste using an existing 1.3 million gallon waste tank (i.e., Tank 41H) to house the process. Savannah River National Laboratory (SRNL) is conducting pilot-scale mixing tests to determine the pump requirements for suspending and resuspending Monosodium Titanate (MST), Crystalline Silicotitanate (CST), and simulated sludge. In addition, SRNL will also be conducting pilot-scale tests to determine the mixing requirements for the strontium and actinide sorption. As part of this task, the results from the pilot-scale tests must be scaled up to a full-scale waste tank. This document describes the scaling approach. The pilot-scale tank is a 1/10.85 linear scale model of Tank 41H. The tank diameter, tank liquid level, pump nozzle diameter, pump elevation, and cooling coil diameter are all 1/10.85 of their dimensions in Tank 41H. The pump locations correspond to the proposed locations in Tank 41H by the SCIX Program (Risers B5 and B2 for two pump configurations and Risers B5, B3, and B1 for three pump configurations). MST additions are through Riser E1, the proposed MST addition riser in Tank 41H. To determine the approach to scaling the results from the pilot-scale tank to Tank 41H, the authors took the following approach. They reviewed the technical literature for methods to scale mixing with jets and suspension of solid particles with jets, and the technical literature on mass transfer from a liquid to a solid particle to develop approaches to scaling the test data. SRNL assembled a team of internal experts to review the scaling approach and to identify alternative approaches that should be considered.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Characterization Results for the September 2023 Tank Farm 3H Evaporator Overhead Sample

On an annual basis, Savannah River Mission Completion (SRMC) provides 2H and 3H evaporator overhead samples to Savannah River National Lab (SRNL) to be analyzed per Section 5.2 of the Effluent Treatment Project (ETP) Waste Compliance Plan (WCP) and the Waste Acceptance Criteria (WAC). This report presents the average characterization results for the September 2023 3H evaporator overhead sample. The sample was clear and colorless with no visible solids. The results provide measurements for cesium-137 ( 137 Cs), strontium-90 ( 90 Sr), and iodine-129 ( 129 I) with the radionuclide concentration limits specified by the WAC. These analyses were performed in duplicate, and all three measured radionuclide concentrations were within ETP WAC limits. A summary of the analytical results for this 3H evaporator overhead sample includes the following: The measured cesium-137 activity in the 3H evaporator overhead sample averaged 5.70E+01 dpm/mL, which is below the ETP WAC limit of 1.30E+03 dpm/mL. As seen through historical results, Cs-137 continues to present a decreasing activity since 2020. The strontium-90 activity in the 3H evaporator overhead sample averaged <2.16E00 dpm/mL, which is below the ETP WAC limit of 1.76E+02 dpm/mL. The iodine-129 activity in the 3H evaporator overhead sample averaged <9.08E-02 dpm/mL, which is below the ETP WAC limit of 1.00E+00 dpm/mL

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Characterization Results for the October 2024 Tank Farm 3H Evaporator Overhead Sample

On an annual basis, Savannah River Mission Completion (SRMC) provides 2H and 3H evaporator overhead samples to Savannah River National Lab (SRNL) to be analyzed per Section 5.2 of the Effluent Treatment Project (ETP) Waste Compliance Plan (WCP) and the Waste Acceptance Criteria (WAC). This report presents characterization results for the October 2024 3H evaporator overhead sample. The sample was clear and colorless with no visible solids. The results provide measurements for cesium-137 (137Cs), strontium-90 (90Sr), and iodine-129 (129I) with the radionuclide concentration limits specified by the WAC. These analyses were performed in duplicate, and a summary of the analytical results for this 3H evaporator overhead sample includes the following: The measured cesium-137 activity in the 3H evaporator overhead sample averaged 6.72E+01 dpm/mL, (3.90E+00 %RSD), which is below the ETP WAC limit of 1.30E+03 dpm/mL. The strontium-90 activity in the 3H evaporator overhead sample averaged <2.72E+00 dpm/mL, which is below the ETP WAC limit of 1.76E+02 dpm/mL. The iodine-129 activity in the 3H evaporator overhead sample averaged <1.63E-01 dpm/mL, which is below the ETP WAC limit of 1.00E+00 dpm/mL.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Characterization Results for the August 2025 Tank Farm 2H Evaporator Overhead Sample

On an annual basis, Savannah River Mission Completion (SRMC) provides 2H and 3H evaporator overhead samples to Savannah River National Lab (SRNL) to be analyzed per Section 5.2 of the Effluent Treatment Project (ETP) Waste Compliance Plan (WCP) and the Waste Acceptance Criteria (WAC). This report presents the average characterization results for the August 2025 2H evaporator overhead sample. The sample was clear and colorless with no visible solids. The results provide measurements for cesium-137 ( 137 Cs), strontium-90 ( 90 Sr), and iodine-129 ( 129 I) with the radionuclide concentration limits specified by the WAC. These analyses were performed in duplicate, and all three measured radionuclide concentrations were within ETP WAC limits. A summary of the analytical results for this 2H evaporator overhead sample includes the following: The measured cesium-137 activity in the 2H evaporator overhead sample averaged 3.02E+02 dpm/mL, which is below the ETP WAC limit of 1.30E+03 dpm/mL. The strontium-90 activity in the 2H evaporator overhead sample averaged 3.33E+00 dpm/mL, which is below the ETP WAC limit of 1.76E+02 dpm/mL. The iodine-129 activity in the 2H evaporator overhead sample averaged 1.20E-01 dpm/mL, which is below the ETP WAC limit of 1.00E+00 dpm/mL. Although the measurements for Cs-137 and Sr-90 are lower compared to previous years, the results remain within a similar range to past measurements and are well below the WAC limits. Iodine-129 indicates detectable results compared to previous years, which can be attributed to recent salt batch processing trending close to the WAC limit for saltstone production. However, these results are still below the ETP WAC limit.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

OPTIMIZED MONOSODIUM TITANATE PHASE II SUPPLEMENTAL TESTING REPORT URANIUM ADSORPTION AND SHELF-LIFE MEASUREMENTS

The DOE Office of Waste Processing recently funded supplemental Phase II testing to further investigate the uranium affinity and shelf-life of modified monosodium titanate (mMST). Testing results confirmed earlier findings that the mMST exhibits much lower affinity for uranium than the baseline monosodium titanate (MST) material. The loading of uranium onto the mMST sample measured more than an order of magnitude lower than that of the MST. This finding indicates that the use of mMST provides a significant advantage over MST in that the mMST will not concentrate enriched uranium to the degree that MST does. The reduced affinity of mMST for uranium allows more operational flexibility in treating waste solutions from a nuclear criticality safety perspective. Testing results also indicate that the mMST exhibits good shelf-life with no measurable loss in plutonium and neptunium removal upon storage of samples at ambient laboratory temperatures for up to 30-months. Testing did exhibit a change in strontium removal performance for both the mMST and MST samples at the most recent testing event. However, the decrease in strontium removal performance proved lower for the mMST than the MST sample. Given these positive findings SRNL recommends continued development of mMST as a replacement for MST in pretreatment facilities at the Savannah River Site (SRS).

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Ceramic Hosts for Fission Products Immobilization

Natural spinel, perovskite and zirconolite rank among the most leach resistant of mineral forms. They also have a strong affinity for a large number of other elements and including actinides. Specimens of natural perovskite and zirconolite were radioisotope dated and found to have survived at least 2 billion years of natural process while still remain their loading of uranium and thorium . Developers of the Synroc waste form recognized and exploited the capability of these minerals to securely immobilize TRU elements in high-level waste . However, the Synroc process requires a relatively uniform input and hot pressing equipment to produce the waste form. It is desirable to develop alternative approaches to fabricate these durable waste forms to immobilize the radioactive elements. One approach is using a high temperature process to synthesize these mineral host phases to incorporate the fission products in their crystalline structures. These mineral assemblages with immobilized fission products are then isolated in a durable high temperature glass for periods measured on a geologic time scale. This is a long term research concept and will begin with the laboratory synthesis of the pure spinel (MgAl2O4), perovskite (CaTiO3) and zirconolite (CaZrTi2O7) from their constituent oxides. High temperature furnace and/or thermal plasma will be used for the synthesis of these ceramic host phases. Nonradioactive strontium oxide will be doped into these ceramic phases to investigate the development of substitutional phases such as Mg1-xSrxAl2O4, Ca1-xSrxTiO3 and Ca1-xSrxZrTi2O7. X-ray diffraction will be used to establish the crystalline structures of the pure ceramic hosts and the substitution phases. Scanning electron microscopy and energy dispersive X-ray analysis (SEM-EDX) will be performed for product morphology and fission product surrogates distribution in the crystalline hosts. The range of strontium doping is planned to reach the full substitution of the divalent metal ions, Mg and Ca, in the ceramic host phases. The immobilization of rear earth (lanthanide series) fission products in these ceramic host phases will also be studied this year. Cerium oxide is chosen to represent the rear earth fission product for substitution studies in spinel, perovskite and zirconolite ceramic hosts. Cerium has +3 and +4 oxidation states and it can replace some of the trivalent or tetravalent host ions to produce the substitution ceramics such as MgAl2-xCexO4, CaTi1-xCexO3, CaZr1-xCexTi2O7 and CaZrTi2-xCexO7. X-ray diffraction analysis will be used to compare the crystalline structures of the pure ceramic hosts and the substitution phases. SEM-EDX analysis will be used to study the Ce distribution in the ceramic host phases. The range of cerium doping is planned to reach the full substitution of the trivalent or tetravalent ions, Al, Ti and Zr, in the ceramic host phases.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Small Column Ion Exchange Design and Safety Strategy

Small Column Ion Exchange (SCIX) is a transformational technology originally developed by the Department of Energy (DOE) Environmental Management (EM-30) office and is now being deployed at the Savannah River Site (SRS) to significantly increase overall salt processing capacity and accelerate the Liquid Waste System life-cycle. The process combines strontium and actinide removal using Monosodium Titanate (MST), Rotary Microfiltration, and cesium removal using Crystalline Silicotitanate (CST, specifically UOP IONSIV{reg_sign}IE-911 ion exchanger) to create a low level waste stream to be disposed in grout and a high level waste stream to be vitrified. The process also includes preparation of the streams for disposal, e.g., grinding of the loaded CST material. These waste processing components are technically mature and flowsheet integration studies are being performed including glass formulations studies, application specific thermal modeling, and mixing studies. The deployment program includes design and fabrication of the Rotary Microfilter (RMF) assembly, ion-exchange columns (IXCs), and grinder module, utilizing an integrated system safety design approach. The design concept is to install the process inside an existing waste tank, Tank 41H. The process consists of a feed pump with a set of four RMFs, two IXCs, a media grinder, three Submersible Mixer Pumps (SMPs), and all supporting infrastructure including media receipt and preparation facilities. The design addresses MST mixing to achieve the required strontium and actinide removal and to prevent future retrieval problems. CST achieves very high cesium loadings (up to 1,100 curies per gallon (Ci/gal) bed volume). The design addresses the hazards associated with this material including heat management (in column and in-tank), as detailed in the thermal modeling. The CST must be size reduced for compatibility with downstream processes. The design addresses material transport into and out of the grinder and includes provisions for equipment maintenance including remote handling. The design includes a robust set of nuclear safety controls compliant with DOE Standard (STD)-1189, Integration of Safety into the Design Process. The controls cover explosions, spills, boiling, aerosolization, and criticality. Natural Phenomena Hazards (NPH) including seismic event, tornado/high wind, and wildland fire are considered. In addition, the SCIX process equipment was evaluated for impact to existing facility safety equipment including the waste tank itself. SCIX is an innovative program which leverages DOE's technology development capabilities to provide a basis for a successful field deployment.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

PILOT SCALE TESTING OF MONOSODIUM TITANATE MIXING FOR THE SRS SMALL COLUMN ION EXCHANGE PROCESS - 11224

The Small Column Ion Exchange (SCIX) process is being developed to remove cesium, strontium, and select actinides from Savannah River Site (SRS) Liquid Waste using an existing waste tank (i.e., Tank 41H) to house the process. Savannah River National Laboratory (SRNL) is conducting pilot-scale mixing tests to determine the pump requirements for suspending monosodium titanate (MST), crystalline silicotitanate (CST), and simulated sludge. The purpose of this pilot scale testing is to determine the requirements for the pumps to suspend the MST particles so that they can contact the strontium and actinides in the liquid and be removed from the tank. The pilot-scale tank is a 1/10.85 linear scaled model of SRS Tank 41H. The tank diameter, tank liquid level, pump nozzle diameter, pump elevation, and cooling coil diameter are all 1/10.85 of their dimensions in Tank 41H. The pump locations correspond to the proposed locations in Tank 41H by the SCIX program (Risers B5 and B2 for two pump configurations and Risers B5, B3, and B1 for three pump configurations). The conclusions from this work follow: (i) Neither two standard slurry pumps nor two quad volute slurry pumps will provide sufficient power to initially suspend MST in an SRS waste tank. (ii) Two Submersible Mixer Pumps (SMPs) will provide sufficient power to initially suspend MST in an SRS waste tank. However, the testing shows the required pump discharge velocity is close to the maximum discharge velocity of the pump (within 12%). (iii) Three SMPs will provide sufficient power to initially suspend MST in an SRS waste tank. The testing shows the required pump discharge velocity is 66% of the maximum discharge velocity of the pump. (iv) Three SMPs are needed to resuspend MST that has settled in a waste tank at nominal 45 C for four weeks. The testing shows the required pump discharge velocity is 77% of the maximum discharge velocity of the pump. Two SMPs are not sufficient to resuspend MST that settled under these conditions.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Radionuclide partitioning in the modified Unex process

The Universal Extraction (UNEX) process has been developed for simultaneous extraction of long-lived radionuclides (cesium, strontium, actinides, and lanthanides) from acidic solutions in one extraction cycle. Modification of this organic solvent through the use of diamides of dipicolinic acid instead of CMPO increases the extraction capacity of UNEX solvent toward lanthanides and actinide metals, allowing for the processing of spent nuclear fuel. The possibility of radionuclide group separation using the modified UNEX solvent [HCCD (chlorinated cobalt dicarbollide), TBDPA (tetrabutyl-diamide of dipicolinic acid), PEG in FS-1 3 (phenyl-trifluoromethyl-sulfone)] is being investigated. Individual strip products, including a) actinides and lanthanides, b) strontium, and c) cesium, can be obtained by selective stripping from UNEX solvent. Such partitioning will make it possible to transform the Cs/Sr product into the most stable matrices for long-term storage and to further process the actinide/lanthanide product for recycling to a nuclear reactor. (authors)

07 ISOTOPE AND RADIATION SOURCES↗

Heat treatment effects on dielectric properties of SRFe{sub 12}O{sub 19} hexaferrite prepared by an SHS route

The M-type Strontium Hexaferrite SRFe{sub 12}O{sub 19} particles were prepared by a Self propagating High temperature Synthesis (SHS) route. Precursors were heated under two different conditions: microwave heating for 30 minutes and sintered at 950 deg C for 4 hrs. The dielectric properties: dielectric constant ({epsilon}{sup '}), dielectric loss (tan {delta} ) and ac conductivity ({sigma}{sub ac}) were measured at room temperature in the frequency range from 100 Hz to 2 MHz. The samples present a non-linear behavior for the dielectric constant at 1 kHz, 100 kHz and 2 MHz. The dielectric properties of prepared Strontium Hexaferrite samples were discussed in view of applications as a material for microwave devices, permanent magnets and high density magnetic recording media. (author)

36 MATERIALS SCIENCE↗

Performance Test on Polymer Waste Form - 12137

Polymer solidification was attempted to produce stable waste form for the boric acid concentrates and the dewatered spent resins. The polymer mixture was directly injected into the mold or drum which was packed with the boric acid concentrates and the dewatered spent resins, respectively. The waste form was produced by entirely curing the polymer mixture. A series of performance tests was conducted including compressive strength test, water immersion test, leach test, thermal stability test, irradiation stability test and biodegradation stability test for the polymer waste forms. From the results of the performance tests for the polymer waste forms, it is believed that the polymer waste form is very stable and can satisfy the acceptance criteria for permanent disposal. At present, performance tests with full scale polymer waste forms are being carried out in order to obtain qualification certificate by the regulatory institute in Korea. Polymer waste forms were prepared with the surrogate of boric acid concentrates and the surrogate of spent ion exchange resins respectively. Waste forms were also made in lab scale and in full scale. Lab. scale waste forms were directly subjected to a series of the performance tests. In the case of full scale waste form, the test specimens for the performance test were taken from a part of waste form by coring. A series of performance tests was conducted including compressive strength test, thermal stability test, irradiation stability test and biodegradation stability test, water immersion test, leach test, and free standing water for the polymer waste forms. In addition, a fire resistance test was performed on the waste forms by the requirement of the regulatory institute in Korea. Every polymer waste forms containing the boric acid concentrates and the spent ion exchange resins had exhibited excellent structural integrity of more than 27.58 MPa (4,000 psi) of compressive strength. On thermal stability testing, biodegradation testing and water immersion testing, no degradation was observed in the waste forms. Also, by measuring the compressive strength after these tests, it was confirmed that the structural integrity was still retained. A leach test was performed by using non radioactive cobalt, cesium and strontium. The leaching of cobalt, cesium and strontium from the polymer waste forms was very low. Also, the polymer waste forms were found to possess adequate fire resistance. From the results of the performance tests, it is believed that the polymer waste form is very stable and can satisfy the acceptance criteria for permanent disposal. At present, Performance tests with full scale polymer waste forms are on-going in order to obtain qualification certificate by the regulatory institute in Korea. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Evaluation of a low cost humate solution as an in situ amendment to enhance attenuation of uranium in an acidic plume - 15445

A single well injection test was conducted in the acidic portion of a groundwater contamination plume beneath the F-Area Seepage Basins on the U.S. Department of Energy's Savannah River Site to evaluate humate as a viable amendment to enhance attenuation of uranium and other radionuclides. Humate is typically used as an inexpensive organic fertilizer. A solution of humate was injected into a monitoring well in the heart of the F-Area Seepage Basins plume. The geochemical conceptual model suggests humate adsorbs to mineral surfaces creating a subsurface treatment zone in which uranium adsorption is enhanced. Following humate injection, groundwater was sampled from the injection well at regular intervals to determine the composition of groundwater and to evaluate the sorption of contaminants within the treatment zone. Attenuation of uranium, radioiodine and Strontium-90 was determined by comparing concentrations to analytes unaffected by the humate, specifically tritium, nitrate, and specific conductance. The post-injection monitoring data showed enhanced uranium attenuation in the treatment zone as uranium concentrations rebounded to only 68% of the pre-test concentrations. Radioiodine attenuation was complicated by changing speciation during the test. When pH was elevated by the humate injection, iodate dominated and enhanced attenuation was observed. As pH decreased, iodide dominated and enhanced attenuation decreased. Humate did not significantly attenuate Strontium-90. Results of the humate injection test demonstrate that humate strongly adsorbs to the aquifer sediments at acidic pH. Humate desorption curves suggest that a substantial fraction of humate will remain adsorbed to the sediments for long-periods of time. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Filtration Improvements in Support of Increased Salt Waste Processing Throughput at the Savannah River Site - 16173

Crossflow Filtration is currently used at the U.S. Department of Energy (DOE) Savannah River Site (SRS) for the removal of actinides, strontium and sludge solids from the high-level salt waste stored in underground tanks. At SRS, crossflow filtration is deployed in the Actinide Removal Process (ARP). Salt waste is transferred from an underground waste tank to one of two strike tanks where it is struck with Monosodium Titanate (MST), which adsorbs uranium, plutonium and strontium. The MST laden salt waste is then transferred to the ARP filtration facility, which contains the crossflow filter. The filtrate, which is called Clarified Salt Solution (CSS), is sent to a downstream facility for cesium removal, while the MST and sludge solids are concentrated at the filtration facility and eventually sent to the Defense Waste Processing Facility (DWPF) for vitrification. ARP and the downstream cesium removal facility, the Modular Caustic Side Solvent Extraction Unit (MCU), were both developed as an interim salt waste processing technology and as smaller scale radioactive demonstration plants for the Salt Waste Processing Facility (SWPF), which is currently under construction. Since the beginning of ARP in 2008, there have been challenges with achieving desired filtration rates through the crossflow filter system. Historically the crossflow filter system has been the flow limiter in salt waste processing and many changes have been made and are planned to achieve desired throughput, especially as MCU increases its processing capacity. Some of these changes include the design of a new crossflow filter, the implementation of a new process chemistry flowsheet and several operational changes. The modifications to the ARP crossflow filter have helped contribute to periods of record throughput in salt waste processing in FY 2015. This paper will discuss the technical challenges and system limitations of retrofitting an older facility as well as past, present and future modifications to the ARP filtration process in order to achieve salt waste processing goals at SRS. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Sustainable Remediation of Radionuclides By a Common Sense Approach to Enhanced Attenuation - 16441

Development of in situ and relatively passive remedies for treatment of groundwater contaminated by metals and radionuclides is becoming more important because of the difficulty and cost - both to the environment and financially -- of removing these types of contaminants from the subsurface by pump-and-treat or excavation. In situ technologies rely on reactions that tend to remove contaminants from groundwater by partitioning them to solid phases in the aquifer. Monitored natural attenuation (MNA) relies solely on natural reactions to achieve remedial goals. Enhanced attenuation (EA) uses engineered approaches to supplement remediation when MNA is not sufficient to meet remedial goals. Both approaches leave contaminants in the subsurface and require a high burden of proof that contaminants will not be mobilized and become a risk in the future. Proof of the sustained effectiveness of an EA remedy is made much easier by strategic design. In multi-contaminant plumes, it is important to prioritize contaminants according to the risk they pose, with the recognition that one remedy rarely treats all contaminants. The goal for the engineered portion of the remedy should be maximum risk reduction with minimal engineering. Natural attenuation or negotiated alternate concentration levels will often allow low risk contaminants to go untreated. Whenever possible, the remedy should be consistent with the geochemical evolution of the waste site, insuring that the treated immobilized contaminants are likely to remain relatively immobile for long time frames. Finally, use what nature provides geologically, hydrologically, geochemically, or microbiologically in the remedy design. One of the impediments faced by waste site managers in implementing EA remedies is paralysis by perceived complexity. There are things that must be known to design an effective EA remedy, but there is always the temptation to know everything to eliminate the possibility of failure. Furthermore, there are plenty of people warning of failure if all is not known and they are usually willing to help the design team know all, for a price. Yet, the price of trying to eliminate all risk is never implementing an innovative remedy. All parties involved -- scientists/engineers, waste site managers, regulators and stakeholders must assume some degree of risk to deploy an EA remedy. If all parties are to assume some risk, then trust built through close communication from the start is required. The U.S. Department of Energy Office of Environmental Management has funded an applied field research initiative for several years focused, in part, on developing EA remedies for metals and radionuclides using these guiding principles. This approach to EA remedies grew out of developing and deploying a remediation strategy to replace a pump-and-treat system at the F-Area Seepage Basins on the Savannah River Site. The pump-and-treat system was energy intensive, produced several thousand cubic feet of solid radioactive waste per year, and cost $ 1 million per month to operate. The EA remedy that replaced the pump-and-treat is energy efficient, produces no waste, and costs approximately $1 million per year to maintain. At the F-Area Seepage Basins approximately 7 billion liters of low level radioactive waste solutions were disposed in three unlined basins resulting in contaminated groundwater containing various radionuclides and other contaminants. The primary contaminants of concern are tritium, strontium-90, uranium, and iodine-129. Other key features of the contaminant plume are its acidic nature with pH values as low as 3.2, its vertical stratification in the water table aquifer, and the tendency of the most contaminated portions to follow troughs in the top of the clay separating the upper aquifer zone from the lower aquifer zone. The geology was exploited by installing a funnel-and-gate system into the clay with the barrier portion blocking contaminant flow paths in the troughs in the clay. This forces the most contaminated water to flow through the gates where it encounters an in situ treatment zone created by periodic injections of alkaline solution. The flux of tritium has been reduced significantly by the barrier walls. Strontium-90 and uranium are treated by enhanced sorption in the circum-neutral pH treatment zone, consistent with natural geochemical evolution of the waste site from acidic to more neutral pH. An additional in situ treatment zone was created up-gradient of the one of the gates to treat iodine-129. Sub-micrometer diameter silver chloride particles were injected into the aquifer by direct push methods to create the treatment zone. In the laboratory and in a field pilot test the poorly soluble silver chloride particles reacted with iodide to form much less soluble silver iodide. Evaluation of the effectiveness of the silver chloride is ongoing. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

DEVELOPMENT OF A CROSSFLOW FILTER TO REMOVE SOLIDS FROM RADIOACTIVE LIQUID WASTE: COMPARISON OF TEST DATA WITH OPERATING EXPERIENCE - 9119

In 2008, the Savannah River Site (SRS) began treatment of liquid radioactive waste from its Tank Farms. To treat waste streams containing {sup 137}Cs, {sup 90}Sr, and actinides, SRS developed the Actinide Removal Process (ARP) and the Modular Caustic Side Solvent Extraction Unit (MCU). The Actinide Removal Process contacts the waste with monosodium titanate (MST) to sorb strontium and select actinides. After MST contact, the process filters the resulting slurry to remove the MST (with sorbed strontium and actinides) and any entrained sludge. The filtrate is transported to the MCU to remove cesium. The solid particle removed by the filter are concentrated to {approx} 5 wt %, washed to reduce the concentration of dissolved sodium, and transported to the Defense Waste Processing Facility (DWPF) for vitrification. The authors conducted tests with 0.5 {micro} and 0.1 {micro} Mott sintered stainless steel crossflow filter at bench-scale (0.19 ft{sup 2} surface area) and pilot-scale (11.2 ft{sup 2}). The collected data supported design of the filter for the process and identified preferred operating conditions for the full-scale process (230 ft{sup 2}). The testing investigated the influence of operating parameters, such as filter pore size, axial velocity, transmembrane pressure, and solids loading, on filter flux, and validated the simulant used for pilot-scale testing. The conclusions from this work follow: (1) The 0.1 {micro} Mott sintered stainless steel filter produced higher flux than the 0.5 {micro} filter. (2) The filtrate samples collected showed no visible solids. (3) The filter flux with actual waste is comparable to the filter flux with simulated waste, with the simulated waste being conservative. This result shows the simulated sludge is representative of the actual sludge. (4) When the data is adjusted for differences in transmembrane pressure, the filter flux in the Actinide Removal Process is comparable to the filter flux in the bench-scale and pilot-scale testing. (5) Filter flux increased with transmembrane pressure, increased with axial velocity, and decreased with concentration in agreement with classical crossflow filtration theories.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗