Search NASA⌕ Search

SEARCH · Search NASA

Results for “System reliability”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 721 records · Page 40

Development of a Field Demonstration for Cost-Effective Low-Grade Heat Recovery and Use Technology Designed to Improve Efficiency and Reduce Water Usage Rates for a Coal-Fired Power Plant

Coal-based power generation systems provide reliable, low-cost power to the domestic energy sector. These systems consume large amounts of fuel and water to produce electricity and are the target of pending regulations that may require reductions in water use and improvements in thermal efficiency. While efficiency of coal-based generation has improved over time, coal power plants often do not utilize the low-grade heat contained in the flue gas and require large volumes of water for the steam cycle make-up, environmental controls, and for process cooling and heating. Low-grade heat recovery is particularly challenging for coal-fired applications, due in large part to the condensation of acid as the flue gas cools and the resulting potential corrosion of the heat recovery materials. Such systems have also not been of significant interest as recent investments on coal power plants have primarily been for environmental controls due to more stringent regulations. Also, in many regions, fuel cost is still a pass-through to the consumer, reducing the motivation for efficiency improvements. Therefore, a commercial system combining low-grade heat-recovery technologies and associated end uses to cost effectively improve efficiency and/or reduce water consumption has not yet been widely applied. However, pressures from potential new regulations and from water shortages may drive new interest, particularly in the U.S. In an effort to address this issue, the U.S. Department of Energy (DOE) has sought to identify and promote technologies to achieve this goal.

20 FOSSIL-FUELED POWER PLANTS↗

Design of an Integrated Solids Handling System to Maximize Syngas Process Reliability (Cooperative Research and Development Final Report)

The National Renewable Energy Laboratory (NREL), in partnership with Wonderful Renewable Energy (WRE) and Idaho National Laboratory (INL), plans to develop a general methodology for designing integrated biorefinery solids preprocessing, handling, and feeding systems based on the chemical, physical, and mechanical attributes of the starting biomass material. This attribute-driven approach will include detailed feedstock property measurements, iterative computational modeling, and bench-scale testing to design systems for preprocessing, handling, and reactor in-feed, up to and including the selection of the conversion reactor. The initial tests and system design will be conducted using waste material from almond and pistachio growing and production operations (shells, hulls, and wood), targeting the conversion of this material to syngas for electricity production. The methodology will then be generalized to other feedstocks. The purpose of this project is to design an integrated solids handling system to maximize the process reliability of converting almond and pistachio waste to electricity. The design methodology and workflow developed from this example will then be applied to the Feedstock Conversion Interface Consortium (FCIC) benchmark loblolly pine residues, thus demonstrating the robustness of the overall design approach and providing insight and guidance for future conversion systems. V-Grid Energy Systems was brought on as a subcontractor to provide gasifiers and labor to complete gasifier runs.

09 BIOMASS FUELS↗

Reliability enhancement of APR + diverse protection system regarding common cause failures

The Advanced Power Reactor Plus (APR +) nuclear power plant design has been developed on the basis of the APR1400 (Advanced Power Reactor 1400 MWe) to further enhance safety and economics. For the mitigation of Anticipated Transients Without Scram (ATWS) as well as Common Cause Failures (CCF) within the Plant Protection System (PPS) and the Emergency Safety Feature - Component Control System (ESF-CCS), several design improvement features have been implemented for the Diverse Protection System (DPS) of the APR + plant. As compared to the APR1400 DPS design, the APR + DPS has been designed to provide the Safety Injection Actuation Signal (SIAS) considering a large break LOCA accident concurrent with the CCF. Additionally several design improvement features, such as channel structure with redundant processing modules, and changes of system communication methods and auto-system test methods, are introduced to enhance the functional reliability of the DPS. Therefore, it is expected that the APR + DPS can provide an enhanced safety and reliability regarding possible CCF in the safety-grade I and C systems as well as the DPS itself. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Reliability analysis of solar photovoltaic system using hourly mean solar radiation data

This paper presents the hourly mean solar radiation and standard deviation as inputs to simulate the solar radiation over a year. Monte Carlo simulation (MCS) technique is applied and MATLAB program is developed for reliability analysis of small isolated power system using solar photovoltaic (SPV). This paper is distributed in two parts. Firstly various solar radiation prediction methods along with hourly mean solar radiation (HMSR) method are compared. The comparison is carried on the basis of predicted electrical power generation with actual power generated by SPV system. Estimation of solar photovoltaic power using HMSR method is close to the actual power generated by SPV system. The deviation in monsoon months is due to the cloud cover. In later part of the paper various reliability indices are obtained by HMSR method using MCS technique. Load model used is IEEE-RTS. Reliability indices, additional load hours (ALH) and additional power (AP) reduces exponentially with increase in load indicates that a SPV source will offset maximum fuel when all of its generated energy is utilized. Fuel saving calculation is also investigated. Case studies are presented for Sagardeep Island in West Bengal state of India. (author)

14 SOLAR ENERGY↗

Use of a hybrid technology in a critical security system.

Assigning an acceptable level of power reliability in a security system environment requires a methodical approach to design when considering the alternatives tied to the reliability and life of the system. The downtime for a piece of equipment, be it for failure, routine maintenance, replacement, or refurbishment or connection of new equipment is a major factor in determining the reliability of the overall system. In addition to these factors is the condition where the system is static or dynamic in its growth. Most highly reliable security power source systems are supplied by utility power with uninterruptable power source (UPS) and generator backup. The combination of UPS and generator backup with a reliable utility typically provides full compliance to security requirements. In the energy market and from government agencies, there is growing pressure to utilize alternative sources of energy other than fossil fuel to increase the number of local generating systems to reduce dependence on remote generating stations and cut down on carbon effects to the environment. There are also conditions where a security system may be limited on functionality due to lack of utility power in remote locations. One alternative energy source is a renewable energy hybrid system including a photovoltaic or solar system with battery bank and backup generator set. This is a viable source of energy in the residential and commercial markets where energy management schemes can be incorporated and systems are monitored and maintained regularly. But, the reliability of this source could be considered diminished when considering the security system environment where stringent uptime requirements are required.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

A Statistical Testing Approach for Quantifying Software Reliability; Application to an Example System

The U.S. Nuclear Regulatory Commission (NRC) encourages the use of probabilistic risk assessment (PRA) technology in all regulatory matters, to the extent supported by the state-of-the-art in PRA methods and data. Although much has been accomplished in the area of risk-informed regulation, risk assessment for digital systems has not been fully developed. The NRC established a plan for research on digital systems to identify and develop methods, analytical tools, and regulatory guidance for (1) including models of digital systems in the PRA's of nuclear power plants (NPPs), and, (2) incorporating digital systems in the NRC's risk-informed licensing and oversight activities. Under NRC's sponsorship, Brookhaven National Laboratory (BNL) explored approaches for addressing the failures of digital instrumentation and control (I and C) systems in the current NPP PRA framework. Specific areas investigated included PRA modeling digital hardware , development of a philosophical basis for defining software failure , and identification of desirable attributes of quantitative software reliability methods . Based on the earlier research, statistical testing is considered a promising method for quantifying software reliability. It is widely recognized that software failures are due to the triggering of pre-existing defects by the software's operational environment. Software defects can arise from errors made in user requirements or coding errors introduced during the developmental process. The software's operational environment includes factors such as the time history of digital system inputs, communication interfaces, the internal state of the digital system, and external conditions. Thus, software reliability is a function of both the number of pre-existing defects and the presence of a triggering condition caused by the manner in which the software is used. In this paper, we describe a statistical software-testing approach for quantifying software reliability and applied it to the loop-operating control system (LOCS) of an experimental loop of the Advanced Test Reactor (ATR) at Idaho National Laboratory (INL). The work involved collaboration between BNL and INL. The objectives of the study include: (1) Development of a statistical testing approach for estimating software failure probability on demand, the results of which are suitable for including in a probabilistic risk assessment (PRA); and, (2) Application of the approach to the LOCS to estimate its failure probability, and obtain insights into the feasibility, practicality, and usefulness of the estimation in models of digital systems for inclusion in nuclear power plants' PRAs. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Use of a hybrid technology in a critical security system.

Assigning an acceptable level of power reliability in a security system environment requires a methodical approach to design when considering the alternatives tied to the reliability and life of the system. The downtime for a piece of equipment, be it for failure, routine maintenance, replacement, or refurbishment or connection of new equipment is a major factor in determining the reliability of the overall system. In addition to these factors is the condition where the system is static or dynamic in its growth. Most highly reliable security power source systems are supplied by utility power with uninterruptable power source (UPS) and generator backup. The combination of UPS and generator backup with a reliable utility typically provides full compliance to security requirements. In the energy market and from government agencies, there is growing pressure to utilize alternative sources of energy other than fossil fuel to increase the number of local generating systems to reduce dependence on remote generating stations and cut down on carbon effects to the environment. There are also conditions where a security system may be limited on functionality due to lack of utility power in remote locations. One alternative energy source is a renewable energy hybrid system including a photovoltaic or solar system with battery bank and backup generator set. This is a viable source of energy in the residential and commercial markets where energy management schemes can be incorporated and systems are monitored and maintained regularly. But, the reliability of this source could be considered diminished when considering the security system environment where stringent uptime requirements are required.

14 SOLAR ENERGY↗

Reliability Value of Fast State Estimation on Power Systems

Monitoring the state of a power system under stress is key to achieving reliable operation. State estimation and timely measurements become more important when applying and designing corrective control actions (manual and automatic) to arrest or mitigate cascading blackouts. The execution time of each process, including state estimation, should be as short as possible to allow for timely action. In this paper, we provide a methodology for estimating one of the components of value of faster and more frequent state estimation: the reliability value of state estimation to assist corrective control actions for arresting or mitigating cascading blackouts. We present a new algorithm for estimating the time between successive line trips in a cascading failure. The algorithm combines power flow calculations with characteristics of the protection system to estimate the time between successive equipment trips. Using this algorithm, we illustrate the value of fast state estimation by calculating the time remaining for automatic or manual corrective actions after state estimation is finalized.

Power system state estimation, cascading failures,↗

Updated Design of the Italian SuperB Factory Injection System

The ultra high luminosity B-factory (SuperB) project of INFN requires a high performance and reliable injection system, providing electrons at 4 GeV and positrons at 7 GeV, to fulfill the very tight requirements of the collider. Due to the short beam lifetime, continuous injection of electrons and positrons in both High Energy Ring (HER) and Low Energy Ring (LER) is necessary to keep the average luminosity at a high level. An updated version of the injection system, optimized at higher repetition frequency is presented. This scheme includes a polarized electron gun, a positron production scheme with electron/positron conversion at low energy 0.6 GeV, and a 1 GeV damping ring to reduce the injected emittance of the positron beam.

43 PARTICLE ACCELERATORS↗

Resilience Metric Formulation Considering Transactive Systems

To help understand the effects of risk and uncertainty on power system operation, particularly during deleterious events, a model for resilience that defines four specific phases of resilience and associated activity was adopted, refined, and contextualized. Given this model, a comparison is made to the well-established field in power systems of reliability and an integrated framework is developed. The role of transactive energy systems in resilience activity is discussed and the strong alignment between properties of transactive energy systems and resilient systems is made. Finally, a scenario-based framework for risk metrics is proposed; the proposed framework allows for the direct comparison in performance between existing (business-as-usual) and transactive energy systems in improving resilience.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Management of Risk and Uncertainty Through Optimized Co-Operation of Transmission Systems and Microgrids with Responsive Loads (Final Report)

The evolution of the power system to the reliable, efficient and sustainable system of the future will involve development of both demand- and supply-side technology and operations. Ambitious national and state-level goals around the decarbonization of electricity relies on the integration of very high levels of renewable resources, most of which are variable and intermittent. The use of demand response is an ideal approach to counterbalance the intermittency of renewable generation and brings the consumer into the spotlight. Until recently, very little research had been conducted on the co-optimization of these two systems due to computational limitations. However, advances in computational capabilities, and the judicious use of decomposition methods and innovative approximation methods for high-dimension dynamic programming made this goal a viable objective for this project, leading to a fundamental shift in the ability to integrate and fully utilize demand-side resources. To this end, the modeling framework developed introduces a novel co-optimization framework, to include the operations of both the transmission and distribution systems (or microgrids) in operational decision making. This framework was used to analyze renewable and distributed generation along with responsive demand and to compare the capability of co-optimized systems to perform with higher levels of variable renewables. Results show that the use of a bi-level optimization approach is an appropriate structure, capable of co-optimizing a transmission system with multiple distribution systems and microgrids. While increasing the number of connected systems provides increasing flexibility for renewables integration this can also the economic benefits to the low-voltage subsystems with each additional system connected. Comparison of a traditional single-level decision structure with the co-optimization approach illustrates a reduction in overall system cost under co-optimization, while specific cost allocations to transmission and distribution systems are changed.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Management of Risk and Uncertainty Through Optimized Co-Operation of Transmission Systems and Microgrids With Responsive Loads (Final Report)

The evolution of the power system to the reliable, efficient and sustainable system of the future will involve development of both demand- and supply-side technology and operations. Ambitious national and state-level goals around the decarbonization of electricity relies on the integration of very high levels of renewable resources, most of which are variable and intermittent. The use of demand response is an ideal approach to counterbalance the intermittency of renewable generation and brings the consumer into the spotlight. Though individual consumers are interconnected at the low-voltage distribution system, these resources are typically modeled as variables at the transmission network level. Demand-side participation cannot be leveraged effectively without explicitly including the distribution system dynamics in the optimization-based wholesale market operations. This project grew from a vision for co-optimized interaction of distribution systems, or microgrids, with the high-voltage transmission system. In this framework, microgrids encompass consumers, distributed renewables and storage. The energy management system of the lower voltage system (distribution or microgrid) can also sell (buy) excess (necessary) energy from the transmission system. Until recently, very little research had been conducted on the co-optimization of these two systems due to computational limitations. However, advances in computational capabilities, and the judicious use of decomposition methods and innovative approximation methods for high-dimension dynamic programming made this goal a viable objective for this project, leading to a fundamental shift in the ability to integrate and fully utilize demand-side resources. To this end, the modeling framework developed introduces a novel co-optimization framework, to include the operations of both the transmission and distribution systems (or microgrids) in operational decision making. This framework was used to analyze renewable and distributed generation along with responsive demand and to compare the capability of co-optimized systems to perform with higher levels of variable renewables. An ideal microgrid is defined as an electric entity capable of operating in both interconnected (with the high-voltage grid) and islanded mode. As such, the microgrid should incorporate generating units (traditional units and intermittent) and if needed, exchange power with the high-voltage grid. The interplay between the microgrid and high-voltage grid motivated the development of the co-optimization approach to ensure efficient performance of the interconnected network. Results show that the use of a bi-level optimization approach is an appropriate structure, capable of co-optimizing a transmission system with multiple distribution systems and microgrids. While increasing the number of connected systems provides increasing flexibility for renewables integration this can also the economic benefits to the low-voltage subsystems with each additional system connected. Comparison of a traditional single-level decision structure with the co-optimization approach illustrates a reduction in overall system cost under co-optimization, while specific cost allocations to transmission and distribution systems are changed.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Reliability of IGBT in a STATCOM for Harmonic Compensation and Power Factor Correction

With smart grid integration, there is a need to characterize reliability of a power system by including reliability of power semiconductors in grid related applications. In this paper, the reliability of IGBTs in a STATCOM application is presented for two different applications, power factor correction and harmonic elimination. The STATCOM model is developed in EMTP, and analytical equations for average conduction losses in an IGBT and a diode are derived and compared with experimental data. A commonly used reliability model is used to predict reliability of IGBT.

Gopi Reddy, Lakshmi Reddy↗

Sandia’s Liquid-Cooled Data Center Boosts Efficiency and Resiliency

The Federal Energy Management Program (FEMP) encourages federal agencies and organizations to improve data center energy efficiency, which can offer tremendous opportunities for energy and cost savings. In this success story, a novel liquid cooling system provides reliable, resilient, and energy-efficient cooling for high performance computing (HPC) systems at Sandia National Laboratories.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Application of RAM to Facility/Laboratory Design

Reliability, Availability, and Maintainability (RAM) studies are extensively used for mission critical systems (e.g., weapons systems) to predict the RAM parameters at the preliminary design phase. A RAM methodology is presented for predicting facility/laboratory inherent availability (i.e., availability that only considers the steady-state effects of design) at the preliminary design phase in support of Department of Energy (DOE) Order 430.1A (Life Cycle Asset Management) and DOE Order 420.1B (Facility Safety). The methodology presented identifies the appropriate system-level reliability and maintainability metrics and discusses how these metrics are used in a fault tree analysis for predicting the facility/laboratory inherent availability. The inherent availability predicted is compared against design criteria to determine if changes to the facility/laboratory preliminary design are necessary to meet the required availability objective in the final design.

99 GENERAL AND MISCELLANEOUS↗

Analyzing of Balancing Authorities Cooperation Methods with High Variable Generation Penetration

With the rapidly growing penetration level of wind and solar generation, the challenges of managing variability and the uncertainty of intermittent renewable generation become more and more significant. The problem of power variability and uncertainty gets exacerbated when each balancing authority (BA) works locally and separately to balance its own subsystem. The virtual BA concept is based on various forms of collaboration between individual BAs to manage power variability and uncertainty. The virtual BA will have a wide area control capability in managing its operational balancing requirements in different time frames. This coordination results in the improvement of efficiency and reliability of power system operation while facilitating the high level integration of green, intermittent energy resources. Several strategies for virtual BA implementation, such as Area Control Error (ACE) diversity interchange (ADI), variable generation only BA, BA consolidation, dynamic scheduling, and regulation and load following sharing are discussed in this paper. The objective of such strategies is to allow individual BAs within a large power grid to help each other dealing with power variability. Innovative methods have been developed to simulate the balancing operation of BAs. These methods evaluate the BA operation through a number of metrics such as capacity, ramp rate, ramp duration, energy and cycling requirements to evaluate the performance of different virtual BA strategies.

17 WIND ENERGY↗