F-15B 836 Supersonic Research Testbed Capabilities
This presentation gives general information of NASA F-15B tail number 836 research capabilities.
SEARCH · Search NASA
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
This presentation gives general information of NASA F-15B tail number 836 research capabilities.
Explore the source record for details and available documents.
This paper presents initial results that demonstrate the end-to-end operation of the Micro-Precision
VIGILANTE consists of two major components:1. the Viewing Imager/Gimballed Instrumentation Laboratory (VIGIL)- advanced infrared, visible, and ultraviolet sensors with appropriate optics and camera electronics & 2. the Analog Neural Three-dimensional processing Experiment (ANTE)-a massively parallel, neural network-based, high-speed processor.
The end of regularly scheduled Microgravity Science Payload (MSP), shuttle mission(s), the severely limited ability to accommodate the existing low temperature flight hardware on other carriers, and the anticipated delays in the development schedule for the International Space Station (ISS) in combination have left low temperature microgravity investigations with few (if any) flight opportunities until several years into the next millennium.
In 2005, NASA's Origins Program will launch the Space Interferometry Mission (SIM), a 10 meter optical interferometer instrument, into a circular 900 km earth orbit.
This paper will compare the performance of various algorithms using the MAM data, and will aid in our recommendation of how the SIM flight system should process the science and guide interferometer data.
The Space Interferometry Mission (SIM) will be the first flight of an optical interferometer where the scientific return is co-equal with technology development objectives.
Electrified aircraft propulsion (EAP) research is a priority of the National Aeronautics and Space Administration (NASA) for its potential to increase propulsion system efficiency, performance, and operability at the subsystem and vehicle levels while decreasing emissions. These EAP systems demand more advanced control algorithms due to increased complexity. NASA has developed a reconfigurable, hardware-in-the-loop rig to verify control algorithm performance using a sub-scale electro-mechanical system. A novel capability of this rig is the ability to test full scale EAP control algorithms on a sub-scale representation of the electro-mechanical system without turbomachinery/rotors. A novel feature is the use of a physical energy storage device within the electro-mechanical system. A dual spool, parallel hybrid-electric turbofan architecture and energy management control system is tested with the goal of verifying the ability to obtain turbomachinery model operability benefits while controlling sub-scale electro-mechanical hardware. Pre-test predictions of the turbofan model, control, and rig performance were obtained through simulation using a software model of the rig. Theoretical results showing the true performance of the turbofan model were obtained through a software simulation using full-scale mechanical shaft models. The paper compares theoretical, predicted, and actual test results from the turbofan model, energy management control and rig perspectives. The results show that the presence of sub-scale electro-mechanical hardware did not inhibit the energy management algorithm from achieving turbomachinery operability benefits.
Electrified aircraft propulsion (EAP) research is a priority of the National Aeronautics and Space Administration (NASA) for its potential to increase propulsion system efficiency, performance, and operability at the subsystem and vehicle levels while decreasing emissions. These EAP systems demand more advanced control algorithms due to increased complexity. NASA has developed a reconfigurable, hardware-in-the-loop rig to verify control algorithm performance using a sub-scale electro-mechanical system. A novel capability of this rig is the ability to test full scale EAP control algorithms on a sub-scale representation of the electro-mechanical system without turbomachinery/rotors. A novel feature is the use of a physical energy storage device within the electro-mechanical system. A dual spool, parallel hybrid-electric turbofan architecture and energy management control system is tested with the goal of verifying the ability to obtain turbomachinery model operability benefits while controlling sub-scale electro-mechanical hardware. Pre-test predictions of the turbofan model, control, and rig performance were obtained through simulation using a software model of the rig. Theoretical results showing the true performance of the turbofan model were obtained through a software simulation using full-scale mechanical shaft models. The paper compares theoretical, predicted, and actual test results from the turbofan model, energy management control and rig perspectives. The results show that the presence of sub-scale electro-mechanical hardware did not inhibit the energy management algorithm from achieving turbomachinery operability benefits.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Smart buildings are equipped with a plethora of cyber-physical systems, such as Internet of Things (IoT) devices and building automation systems. These devices, especially in commercial buildings, use legacy communications and hardware that were not designed with cybersecurity in mind. With increasing cyber threats in recent years, smart buildings have become an increasing target for attacks, but not enough published data are available from these incidents to study or replicate the scenarios to defend buildings. As part of the U.S. Department of Energy-funded project focusing on developing the Building Intelligence with Layered Defense Using Security-Constrained Optimization and Security Risk Detection (BUILD-SOS) platform, we developed a cybersecurity test bed for smart buildings. This test bed includes a building simulation tool, virtual devices, emulated operational technology networks, and remote hardware-in-the-loop. Using this test bed, we performed different cyberattacks on the smart building model and collected both physical building data, to understand the impacts on the building, and network data, to aid in separating mechanical faults from cyberattacks during the detection. This test bed is a significant tool in protecting smart buildings from cyberattacks because it can aid in both cybersecurity analysis and the evaluation of other cyberattack detection tools by testing the tools in a secure environment without impacting the building operations.
Smart buildings are equipped with a plethora of cyber-physical systems, such as Internet of Things (IoT) devices and building automation systems. These devices, especially in commercial buildings, use legacy communications and hardware that were not designed with cybersecurity in mind. With increasing cyber threats in recent years, smart buildings have become an increasing target for attacks, but not enough published data are available from these incidents to study or replicate the scenarios to defend buildings. As part of the U.S. Department of Energy-funded project focusing on developing the Building Intelligence with Layered Defense Using Security-Constrained Optimization and Security Risk Detection (BUILD-SOS) platform, we developed a cybersecurity test bed for smart buildings. This test bed includes a building simulation tool, virtual devices, emulated operational technology networks, and remote hardware-in-the-loop. Using this test bed, we performed different cyberattacks on the smart building model and collected both physical building data, to understand the impacts on the building, and network data, to aid in separating mechanical faults from cyberattacks during the detection. This test bed is a significant tool in protecting smart buildings from cyberattacks because they can aid in both cybersecurity analysis and the evaluation of cyberattack detection tools by testing the tools in a secure environment without impacting the building operations.
This study aims to accelerate the demonstration of various thermal management systems for data centers using nuclear-generated heat to enhance energy and grid reliability. Utilizing mobile containerized and stationary test beds at INL's High Performance Computing (HPC) facility, this project integrates with various nuclear-related energy systems testing facilities. Key components include immersion cooling apparatus, absorption chillers, and adjustable thermal management simulators. Tasks involve acquiring necessary hardware, sensors, and cooling apparatus, engaging with data center industry stakeholders, and providing a testing platform for algorithms, models, tools, and software. The objective is to expedite the deployment of nuclear-powered data centers, thereby improving energy reliability and affordability.
Abstract not provided.
Not Available