At least 721 records · Page 40

Parametric Analytical Studies for the Nonlinear Dynamic Response of the Tile/Pad Space Shuttle Thermal Protection System

The studies examined for imposed sinusoidal and random motions of the shuttle skin and/or applied tile pressure. Studies are performed using the computer code DYNOTA which takes into account the highly nonlinear stiffening hysteresis and viscous behavior of the pad joining the tile to the shuttle skin. Where available, experimental data are used to confirm the validity of the analysis. Both analytical and experimental studies reveal that the system resonant frequency is very high for low amplitude oscillations but decreases rapidly to a minimum value with increasing amplitude.

Edighoffer, H.↗

Fabrication of titanium multiwall Thermal Protection System (TPS) curved panel

A method is described for fabricating curved T1-6Al-4V multiwall panels having a single radius of curvature of 30.5 cm (12 inches). A panel 30.5 x 30.5 x 1.7 cm (12 x 12 x .688 inch) having 4 dimpled sheets, 5 undimpled sheets, and stepped side closures was designed, fabricated and delivered for evaluation. Tool design for skin and dimpled sheet forming are described as well as layup and liquid interface diffusion bonding.

Blair, W.↗

Extensional, bending and twisting stiffness of Titanium Multiwall Thermal Protection System (TPS)

A test program which determines the extensional, bending and torsional stiffness of various titanium multiwall sandwich configurations is described. It is shown that unlike honeycomb core, the dimpled core is a significant contributor to the stiffness and strength of the sandwich. the extensional stiffness test shows irregularities which are attributed to foil thickness variations and to the difficulty to determine linear values from nonlinear tests.

Meaney, J. E.↗

Assessment of Alternate Thermal Protection Systems for the Space Shuttle Orbiter

Candidate concepts are identified. The impact on the Shuttle Orbiter performance life cycle cost, and risk was assessed and technology advances required to bring the selected TPS to operational readiness are defined. The best system is shown to be a hybrid blend of metallic and carbon-carbon TPS concepts. These alternate concepts offer significant improvements in reusability and are mass competitive with the current ceramic tile reusable surface insulation. Programmatic analysis indicates approximately five years are required to bring the concepts to operational readiness.

Kelly, H. N.↗

Thermal protection in space technology

The provision of heat protection for various elements of space flight apparata has great significance, particularly in the construction of manned transport vessels and orbital stations. A popular explanation of the methods of heat protection in rocket-space technology at the current stage as well as in perspective is provided.

Salakhutdinov, G. M.↗

Catalytic surface effects on space thermal protection system during Earth entry of flights STS-2 through STS-5

An on going orbiter experiment catalytic surface effects experiment being conducted on the Space Shuttle is discussed. The catalytic surface effects experiment was peformed on four of the five flights of Columbia. Temperature time histories and distributions along the midfuselage and wing of the orbiter were used to determine the surface catalytic efficiency of the baseline high temperature reusable surface insulation. Correlation parameters are shown that allow the comparison of all flight data with predictions from the design and surface emittance decreased as a result of contaminants during the five flights of the Space Shuttle.

Stewart, D. A.↗

Life considerations of the shuttle orbiter densified-tile thermal protection system

The Shuttle orbiter themal protection system (TPS) incorporates ceramic reusable surface insulation tiles bonded to the orbiter substructure through a strain isolation pad. Densification of the bonding surface of the tiles increases the static strength of the tiles. The densification proces does not, however, necessarily lead to an equivalent increase in fatigue strength. Investigation of the expected lifetime of densified tile TPS under both sinusoidal loading and random loading simulating flight conditions indicates that the strain isolation pads are the weakest components of the TPS under fatigue loading. The felt pads loosen under repetitive loading and, in highly loaded regions, could possibly cause excessive step heights between tiles causing burning of the protective insulation between tiles. A method of improving the operational lifetime of the TPS by using a strain isolation pad with increased stiffness is presented as is the consequence of the effect of increased stiffness on the tile inplane strains and transverse stresses.

Cooper, P. A.↗

Steady internal flow and aerodynamic loads analysis of shuttle thermal protection system

An analytical model for calculation of ascent steady state tile loading was developed and validated with wind tunnel data. The analytical model is described and results are given. Results are given for loading due to shocks and skin friction. The analysis included calculation of internal flow (porous media flow and channel flow) to obtain pressures and integration of the pressures to obtain forces and moments on an insulation tile. A heat transfer program was modified by using analogies between heat transfer and fluid flow so that it could be used for internal flow calculation. The type of insulation tile considered was undensified reusable surface insulation (RSI) without gap fillers, and the location studied was the lower surface of the orbiter. Force and moment results are reported for parameter variations on surface pressure distribution, gap sizes, insulation permeability, and tile thickness.

Petley, D. H.↗

Pre-stressed thermal protection systems

A hexagonal protective and high temperature resistant system for the Space Shuttle Orbiter consists of a multiplicity of pockets formed by hexagonally oriented spacer bars secured on the vehicle substructure. A packing of low density insulating batt material 18 in each pocket, and a thin protective panel of laterally resilient advanced carbon-carbon material surmounting the peripherals bars and packing. Each panel has three stepped or offset lips on contiguous edges. At the center of each pocket is a fully insulated stanchion secured to and connecting the substructure and panel for flexing the panel toward the substructure and thereby prestressing the panel and forcing the panel edges firmly against the spacer bars.

Dunn, T. J.↗

Electron beam charging of Space Shuttle thermal protection system tiles

Six space shuttle reusable surface insulation tiles were tested in the NASA Lewis Research Center's electron bombardment test facility. The 30-cm-square specimens were assembled by using the same materials and techniques used to apply the tiles to the space shuttle and were composed to 15-cm- and 20-cm-square tiles and pieces on 0.6-cm-thick aluminum substrates. There were two specimens of each of three thicknesses. One specimen of each thickness had gaps of less than 0.1 cm between tiles, and the other had gaps of approximately 0.15 cm. The specimens were exposed to monoenergetic electron beams (2 to 25 keV) with nominal fluxes of 0.1 and 1 nA/sq. cm. Tests were conducted with both grounded and floating substrates. The data presented include charging rates, equilibrium potentials, and substrate currents. There is evidence that discharging occurred.

Staskus, J. V.↗

Development of acceptance criteria for batches of silane primer for external tank thermal protection system bonding applications

Concluding tests for the thermogravimetric and FTIR analyses of DC 1200 silane primers are discussed as well as methods for HPLC and GC analyses and for determining titanium and silicon by atomic absorption spectroscopy. Tables summarizes results obtained for residue, ash, titanium, silicone, Si/Ti ratio, OH-absorption, the lap-shear test, and the GC headspace for alcohols.

Mikes, F.↗

Development of acceptance criteria for batches of silane primer for external tank thermal protection system bonding applications

Fourier transform infrared spectroscopy is currently the best technique for observing hydrolytic changes in DC 1200 silane the primers caused by moisture in the atmosphere. To further prove that FTIR can be used as a criterion test for acceptance of silane primer lots, intensities of the FTIR OH- band are being compared with primer adhesive bond strength using a mechanical test suggested by NASA. Results of tests for shear strength and Oh-absorption are tabulated and compared with FTIR absorption intensities in the OH-region.