Search NASA⌕ Search

SEARCH · Search NASA

Results for “Time resolved imaging”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 721 records · Page 40

NO PLIF flow visualization and time-resolved temperature distributions in laser induced breakdown plumes

NO planar laser induced fluorescence (PLIF) is used to obtain images of laser-induced breakdown plasma plumes in NO-seeded nitrogen and dry air at near atmospheric pressure. Single-shot PLIF-images show that the plume development 5–50 μs after the breakdown pulse is fairly reproducible shot-to-shot, although the plume becomes increasingly stochastic on longer timescales, 100–500 μs. The stochastic behavior of the plume is quantified using probability distributions of the loci of the plume boundary. Analysis of the single-shot images indicates that the mixing of the plume with ambient gas on sub-ms time scale is insignificant. The induced flow velocity in the plume is fairly low, up to 30 m s –1 , suggesting that laser breakdowns are ineffective for mixing enhancement in high speed flows. The ensemble-averaged PLIF images indicate the evolution of the plume from an initially elongated shape to near-spherical to toroidal shape, with a subsequent radial expansion and formation of an axial jet in the center. Temperature distributions in the plume in air are obtained from the NO PLIF images, using two rotational transitions in the NO(X, v' = 0 → A, v'' = 0) band, J'' = 6.5 and 12.5 of the Q R 12 + Q 2 branch. The results indicate that the temperature in the plume remains high, above 1000 K, for approximately 100 μs, after which it decays gradually, to below 500 K at 500 μs. The residual NO fraction in the plume is ~0.1%, indicating that repetitive laser-assisted ignition may result in significant NO-generation. Furthermore, these measured temperature and velocity distributions can be used for detailed validation of kinetic models of laser-induced breakdown and assessment of their predictive capability.

42 ENGINEERING↗

Effects of Plume Hydrodynamics and Oxidation on the Composition of a Condensing Laser-Induced Plasma

High-temperature chemistry in laser ablation plumes leads to vapor-phase speciation, which can induce chemical fractionation during condensation. In this work, using emission spectroscopy acquired after ablation of a SrZrO 3 target, we have experimentally observed the formation of multiple molecular species (ZrO and SrO) as a function of time as the laser ablation plume evolves. Although the stable oxides SrO and ZrO 2 are both refractory, we observed emission from the ZrO intermediate at earlier times than SrO. We deduced the time-scale of oxygen entrainment into the laser ablation plume using an 18 O 2 environment by observing the in-growth of Zr 18 O in the emission spectra relative to Zr 16 O, which was formed by reaction of Zr with 16 O from the target itself. Using temporally resolved plume-imaging, we determined that ZrO formed more readily at early times, volumetrically in the plume, while SrO formed later in time, around the periphery. Lastly, using a simple temperature-dependent reaction model, we have illustrated that the formation sequence of these oxides subsequent to ablation is predictable to first order.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Space- and time-resolved observation of extreme laser frequency upshifting during ultrafast-ionization

A 65-fs, 800-nm, 2-TW laser pulse propagating through a nitrogen gas jet has been experimentally studied by 90° Thomson scattering. Time-integrated spectra of scattered light show unprecedented broadening towards the blue which exceeds 300 nm. Images of the scattering region provide for the first time a space- and time-resolved description of the process leading quite regularly to such a large upshift. The mean shifting rate was as high as δλ/δt ≈ 3 Å/fs, never observed before. Interferometry shows that it occurs after partial laser defocusing. Numerical simulations prove that such an upshift is consistent with a laser-gas late interaction, when laser intensity has decreased well below relativistic values (a{sub 0}≪ 1) and ionization process involves most of the laser pulse. This kind of interaction makes spectral tuning of ultrashort intense laser pulses possible in a large spectral range.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

X-ray characterization of low-thermal conductivity thin-film materials.

X-ray diffraction and imaging techniques at the Advanced Photon Source (APS) have been used to characterize PbSe/MoSe{sub 2} and PbSe/WSe{sub 2} thin films and multilayers. Diffraction measurements with area detectors were made to demonstrate the nanoscale coherence size of the layers both in-plane and perpendicular to the surface. Higher-resolution diffraction measurements that exploit the tunability of synchrotron radiation for anomalous scattering contrast have been used to accurately determine layer spacings in these multilayers. We also discuss opportunities in other new and emerging x-ray techniques, such as time-resolved studies during growth or processing, and present x-ray imaging capabilities that can be used to investigate thermoelectric thin-film materials.

43 PARTICLE ACCELERATORS↗

Time-resolved spectroscopy using a chopper wheel as a fast shutter

Widely available, small form-factor, fiber-coupled spectrometers typically have a minimum exposure time measured in milliseconds, and thus cannot be used directly for time-resolved measurements at the microsecond level. Spectroscopy at these faster time scales is typically done with an intensified charge coupled device (CCD) system where the image intensifier acts as a “fast” electronic shutter for the slower CCD array. In this paper, we describe simple modifications to a commercially available chopper wheel system to allow it to be used as a “fast” mechanical shutter for gating a fiber-coupled spectrometer to achieve microsecond-scale time-resolved optical measurements of a periodically pulsed light source. With the chopper wheel synchronized to the pulsing of the light source, the time resolution can be set to a small fraction of the pulse period by using a chopper wheel with narrow slots separated by wide spokes. Different methods of synchronizing the chopper wheel and pulsing of the light sources are explored. The capability of the chopper wheel system is illustrated with time-resolved measurements of pulsed plasmas.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Simulation of multi-photon emission isotopes using time-resolved SimSET multiple photon history generator

Abstract-Multiple-photon emitters, such as In-111 or Se-75, have enormous potential in the field of nuclear medicine imaging. For example, Se-75 can be used to investigate the bile acid malabsorption and measure the bile acid pool loss. The simulation system for emission tomography (SimSET) is a well-known Monte Carlo simulation (MCS) code in nuclear medicine for its high computational efficiency. However, current SimSET cannot simulate these isotopes due to the lack of modeling of complex decay scheme and the time-dependent decay process. To extend the versatility of SimSET for simulation of those multi-photon emission isotopes, a time-resolved multiple photon history generator based on SimSET codes is developed in present study. For developing the time-resolved SimSET (trSimSET) with radionuclide decay process, the new MCS model introduce new features, including decay time information and photon time-of-flight information, into this new code. The half-life of energy states were tabulated from the Evaluated Nuclear Structure Data File (ENSDF) database. The MCS results indicate that the overall percent difference is less than 8.5% for all simulation trials as compared to GATE. To sum up, we demonstrated that time-resolved SimSET multiple photon history generator can have comparable accuracy with GATE and keeping better computational efficiency. The new MCS code is very useful to study the multi-photon imaging of novel isotopes that needs the simulation of lifetime and the time-of-fight measurements. (authors)

07 ISOTOPE AND RADIATION SOURCES↗

X-ray nanodiffraction imaging reveals distinct nanoscopic dynamics of an ultrafast phase transition

Significance Phase transitions, the changes between states of matter with distinct electronic, magnetic, or structural properties, are at the center of condensed matter physics and underlie valuable technologies. First-order phase transitions are intrinsically heterogeneous. When driven by ultrashort excitation, nanoscale phase regions evolve rapidly, which has posed a significant experimental challenge to characterize. The newly developed laser-pumped X-ray nanodiffraction imaging technique reported here has simultaneous 100-ps temporal and 25-nm spatial resolutions. This approach reveals pathways of the nanoscale structural rearrangement upon ultrafast optical excitation, different from those transitions under slowly varying parameters. The spatiotemporally resolved structural characterization provides crucial nanoscopic insights into ultrafast phase transitions and opens opportunities for controlling nanoscale phases on ultrafast time scales.

36 MATERIALS SCIENCE↗

Probing Motion of Fast Radio Burst Sources by Timing Strongly Lensed Repeaters

Given the possible repetitive nature of fast radio bursts (FRBs), their cosmological origin, and their high occurrence, detection of strongly lensed sources due to intervening galaxy lenses is possible with forthcoming radio surveys. We show that if multiple images of a repeating source are resolved with VLBI, using a method independent of lens modeling, accurate timing could reveal non-uniform motion, either physical or apparent, of the emission spot. This can probe the physical nature of FRBs and their surrounding environments, constraining scenarios including orbital motion around a stellar companion if FRBs require a compact star in a special system, and jet-medium interactions for which the location of the emission spot may randomly vary. The high timing precision possible for FRBs (∼ms) compared with the typical time delays between images in galaxy lensing (≳10 days) enables the measurement of tiny fractional changes in the delays (∼10{sup −9}) and hence the detection of time-delay variations induced by relative motions between the source, the lens, and the Earth. We show that uniform cosmic peculiar velocities only cause the delay time to drift linearly, and that the effect from the Earth’s orbital motion can be accurately subtracted, thus enabling a search for non-trivial source motion. For a timing accuracy of ∼1 ms and a repetition rate (of detected bursts) of ∼0.05 per day of a single FRB source, non-uniform displacement ≳0.1–1 au of the emission spot perpendicular to the line of sight is detectable if repetitions are seen over a period of hundreds of days.

79 ASTRONOMY AND ASTROPHYSICS↗

Spectral Variability of VHS J1256–1257b from 1 to 5 μm

Multiwavelength time-resolved observations of rotationally modulated variability from brown dwarfs and giant exoplanets are the most effective method for constraining their heterogeneous atmospheric structures. In a companion paper, we reported the discovery of strong near-infrared variability in HST/WFC3/G141 light curves of the very red L-dwarf companion VHS J1256–1257b. In this paper, we present a follow-up 36 hr Spitzer/IRAC Channel 2 light curve together with an in-depth analysis of the Hubble space telescope (HST) and the Spitzer data. The combined data set provides time-resolved light curves of VHS1256b sampling 1.1 to 4.5 μm. The Spitzer light curve is best fit with a single sine wave with a period of 22.04 ± 0.05 hr and a peak-to-peak amplitude of 5.76 ± 0.04%. Combining the period with a previously measured projected rotational velocity (v sin i), we find that VHS1256b is most consistent with equatorial viewing geometry. The HST/G141+Spitzer spectral energy distribution favors a model with a T{sub eff} of 1000 K and low surface gravity with disequilibrium chemistry. The spectral variability of VHS1256b is consistent with predictions from partly cloudy models, suggesting that heterogeneous clouds are the dominant source of the observed modulations. We find evidence at the 3.3σ level for amplitude variations within the 1.67 μm CH{sub 4} band, which is the first such detection for a variable L-dwarf. We compare the HST/G141 time-resolved spectra of three red L-dwarfs with high-amplitude near-infrared rotational modulations and find that although their time-averaged spectra are similar, their spectroscopic variabilities exhibit notable differences. This diversity reinforces the advantage of time-resolved spectroscopic observations for understanding the atmospheres of brown dwarfs and directly imaged exoplanets.

79 ASTRONOMY AND ASTROPHYSICS↗

Commissioning a time-gated camera for fast neutron beamline spatial-energy characterization at LANSCE-WNR spallation source

An energy-resolved fast neutron beam imaging diagnostic has been successfully commissioned at the Weapons Neutron Research (WNR) spallation source within the Los Alamos Neutron Science Center (LANSCE) facility. This diagnostic replaces the existing analog phosphor image plates, which integrate across all neutron energies, as well as other particles, with a near-real-time energy-sensitive imaging capability. The system uses a fast plastic scintillator coupled with an intensified CCD camera. Specifically, the Teledyne Pi-MAX4 camera is coupled with either a 4 mm thick Eljen (EJ) 204 or 228 plastic scintillator. These scintillators are most sensitive to the fast neutrons (0.8-800 MeV) directly from the spallation source rather than low energy background radiation. Experimentally, these plastic scintillators were shown to have sufficiently fast decay to differentiate the bright gamma flash from the spallation neutrons. The spatial resolution is dominated by neutron beam divergence, with minimal additional contributions from scatter and light divergence. The system successfully resolved changes in neutron beam characteristics caused by intentional proton steering variations. Additionally, simulations of scintillator light yield as a function of thickness conducted using PHITS (with Scinful-QMD package) found that increasing scintillator thickness from 4 mm to 6 or 8 mm could potentially increase brightness ~ 3x. This may be explored if there is a need to reduce image acquisition time from several minutes to under one minute.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Direct Visualization of Charge Migration in Bilayer Tantalum Oxide Films by Multimodal Imaging

Inspired by biological neuromorphic computing, artificial neural networks based on crossbar arrays of bilayer tantalum oxide memristors have shown to be promising alternatives to conventional complementary metal-oxide-semiconductor (CMOS) architectures. In order to understand the driving mechanism in these oxide systems, tantalum oxide films are resistively switched by conductive atomic force microscopy (C-AFM), and subsequently imaged by kelvin probe force microscopy (KPFM) and spatially resolved time-of-flight secondary ion mass spectrometry (ToF-SIMS). These workflows enable induction and analysis of the resistive switching mechanism as well as control over the resistively switched region of the film. In this work it is shown that the resistive switching mechanism is driven by both current and electric field effects. Reversible oxygen motion is enabled by applying low (<1 V) electric fields, while high electric fields generate irreversible breakdown of the material (>1 V). Fully understanding oxygen motion and electrical effects in bilayer oxide memristor systems is a fundamental step toward the adoption of memristors as a neuromorphic computing technology.

36 MATERIALS SCIENCE↗

Fluorescence-Correlation Spectroscopy Study of Molecular Transport within Reversed-Phase Chromatographic Particles Compared to Planar Model Surfaces

Reversed-phase liquid chromatography (RPLC) is a widely used technique for molecular separations. Stationary-phase materials for RPLC generally consist of porous silica-gel particles functionalized with n-alkane ligands. Understanding motions of molecules within the interior of these particles is important for developing efficient chromatographic materials and separations. To characterize these dynamics, time-resolved spectroscopic methods (photobleach recovery, fluorescence correlation, single-molecule imaging) have been adapted to measure molecular diffusion rates, typically at n-alkane-modified planar silica surfaces, which serve as models of chromatographic interfaces. A question arising from these studies is how dynamics of molecules on a planar surface relate to motions of molecules within the interior of a porous chromatographic particle. In this paper, imaging-fluorescence-correlation spectroscopy is used to measure diffusion rates of a fluorescent probe molecule 1,1'-dioctadecyl-3,3,3'3'-tetramethylindocarbocyanine perchlorate (DiI) within authentic RPLC porous silica particles and compared with its diffusion at a planar C18-modified surface. The results show that surface diffusion on the planar C18 substrate is much faster than the diffusion rate of the probe molecule through a chromatographic particle. Surface diffusion within porous particles, however, is governed by molecular trajectories along the tortuous contours of the interior surface of the particles. By accounting for the greater surface area that a molecule must explore to diffuse macroscopic distances through the particle, the molecular-scale diffusion rates on the two surfaces can be compared, and they are virtually identical. Furthermore, these results provide support for the relevance of surface-diffusion measurements made on planar model surfaces to the dynamic behavior of molecules on the internal surfaces of porous chromatographic particles.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Super-resolution with a positive epsilon multi-quantum-well super-lens

We design an anisotropic and dichroic quantum metamaterial that is able to achieve super-resolution without the need for a negative permittivity. When exploring the parameters of the structure, we take into account the limits of semiconductor fabrication technology based on quantum well stacks. By heavily doping the structure with free electrons, we infer an anisotropic effective medium with a prolate ellipsoid dispersion curve which allows for near-diffractionless propagation of light (similar to an epsilon-near-zero hyperbolic lens). This, coupled with low absorption, allows us to resolve images at the sub-wavelength scale at distances 6 times greater than equivalent natural materials.

36 MATERIALS SCIENCE↗

THE QSO HE 0450-2958: SCANTILY DRESSED OR HEAVILY ROBED? A NORMAL QUASAR AS PART OF AN UNUSUAL ULIRG

The luminous z = 0.286 quasar HE 0450-2958 is interacting with a companion galaxy at 6.5 kpc distance and the whole system radiates in the infrared (IR) at the level of an ultraluminous infrared galaxy (ULIRG). A so far undetected host galaxy triggered the hypothesis of a mostly 'naked' black hole (BH) ejected from the companion by three-body interaction. We present new Hubble Space Telescope (HST)/NICMOS 1.6 {mu}m imaging data at 0.''1 resolution and VLT/VISIR 11.3 {mu}m images at 0.''35 resolution that are for the first time resolving the system in the near- and mid-infrared. We combine these data with existing optical HST and CO maps. (1) At 1.6 {mu}m we find an extension NE of the quasar nucleus that is likely a part of the host galaxy, though not its main body. If true, a combination with upper limits on a main body co-centered with the quasar brackets the host-galaxy luminosity to within a factor of {approx}4 and places HE 0450-2958 directly onto the M{sub BH} - M{sub bulge} relation for nearby galaxies. (2) A dust-free line of sight to the quasar suggests a low dust obscuration of the host galaxy, but the formal upper limit for star formation (SF) lies at 60 M{sub sun} yr{sup -1}. HE 0450-2958 is consistent with lying at the high-luminosity end of Narrow-Line Seyfert 1 Galaxies, and more exotic explanations like a 'naked quasar' are unlikely. (3) All 11.3 {mu}m radiation in the system is emitted by the quasar nucleus. It has warm ULIRG-strength IR emission powered by BH accretion and is radiating at super-Eddington rate, L/L{sub Edd} = 6.2{sup +3.8}{sub -1.8}, or 12 M{sub sun} yr{sup -1}. (4) The companion galaxy is covered in optically thick dust and is not a collisional ring galaxy. It emits in the far-infrared at ULIRG strength, powered by Arp220-like SF (strong starburst-like). An M82-like SED is ruled out. (5) With its BH accretion rate, HE 0450-2958 produces not enough new stars to maintain its position on the M{sub BH} - M{sub bulge} relation, and SF and BH accretion are spatially disjoint. This relation can either only be maintained averaging over a longer timescale ({approx}<500 Myr) and/or the bulge has to grow by redistribution of pre-existing stars. (6) Systems similar to HE 0450-2958 with spatially disjoint ULIRG-strength star formation and quasar activity might be common at high redshifts but at z < 0.43 we only find <4% (3/77) candidates for a similar configuration.

99 GENERAL AND MISCELLANEOUS↗

The Science Case for Spacecraft Exploration of the Uranian Satellites: Candidate Ocean Worlds in an Ice Giant System

The 27 satellites of Uranus are enigmatic, with dark surfaces coated by material that could be rich in organics. Voyager 2 imaged the southern hemispheres of Uranus’s five largest “classical” moons—Miranda, Ariel, Umbriel, Titania, and Oberon, as well as the largest ring moon, Puck—but their northern hemispheres were largely unobservable at the time of the flyby and were not imaged. Additionally, no spatially resolved data sets exist for the other 21 known moons, and their surface properties are essentially unknown. Because Voyager 2 was not equipped with a near-infrared mapping spectrometer, our knowledge of the Uranian moons’ surface compositions, and the processes that modify them, is limited to disk-integrated data sets collected by ground- and space-based telescopes. Nevertheless, images collected by the Imaging Science System on Voyager 2 and reflectance spectra collected by telescope facilities indicate that the five classical moons are candidate ocean worlds that might currently have, or had, liquid subsurface layers beneath their icy surfaces. To determine whether these moons are ocean worlds, and to investigate Uranus’s ring moons and irregular satellites, close-up observations and measurements made by instruments on board a Uranus orbiter are needed.

Richard J. Cartwright↗

Fragmentation kinematics in comet 332P/Ikeya-Murakami

We present initial time-resolved observations of the split comet 332P/Ikeya–Murakami taken using the Hubble Space Telescope. Our images reveal a dust-bathed cluster of fragments receding from their parent nucleus at projected speeds in the range 0.06–3.5 m s{sup −1} from which we estimate ejection times from 2015 October to December. The number of fragments with effective radii ≳20 m follows a differential power law with index γ = −3.6 ± 0.6, while smaller fragments are less abundant than expected from an extrapolation of this power law. We argue that, in addition to losses due to observational selection, torques from anisotropic outgassing are capable of destroying the small fragments by driving them quickly to rotational instability. Specifically, the spin-up times of fragments ≲20 m in radius are shorter than the time elapsed since ejection from the parent nucleus. The effective radius of the parent nucleus is r{sub e} ⩽ 275 m (geometric albedo 0.04 assumed). This is about seven times smaller than previous estimates and results in a nucleus mass at least 300 times smaller than previously thought. The mass in solid pieces, 2×10{sup 9} kg, is about 4% of the mass of the parent nucleus. As a result of its small size, the parent nucleus also has a short spin-up time. Brightness variations in time-resolved nucleus photometry are consistent with rotational instability playing a role in the release of fragments.

79 ASTRONOMY AND ASTROPHYSICS↗

DARKNESS: A Microwave Kinetic Inductance Detector Integral Field Spectrograph for High-contrast Astronomy

We propose DARKNESS (the DARK-speckle Near-infrared Energy-resolving Superconducting Spectrophotometer), the first of several planned integral field spectrographs to use optical/near-infrared Microwave Kinetic Inductance Detectors (MKIDs) for high-contrast imaging. The photon counting and simultaneous low-resolution spectroscopy provided by MKIDs will enable real-time speckle control techniques and post-processing speckle suppression at frame rates capable of resolving the atmospheric speckles that currently limit high-contrast imaging from the ground. DARKNESS is now operational behind the PALM-3000 extreme adaptive optics system and the Stellar Double Coronagraph at Palomar Observatory. In this work, we describe the motivation, design, and characterization of the instrument, early on-sky results, and future prospects.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Blood flow imaging by optimal matching of computational fluid dynamics to 4D-flow data

Three-dimensional, time-resolved blood flow measurement (4D-flow) is a powerful research and clinical tool, but improved resolution and scan times are needed. Therefore, this study aims to (1) present a postprocessing framework for optimization-driven simulation-based flow imaging, called 4D-flow High-resolution Imaging with a priori Knowledge Incorporating the Navier-Stokes equations and the discontinuous Galerkin method (4D-flow HIKING), (2) investigate the framework in synthetic tests, (3) perform phantom validation using laser particle imaging velocimetry, and (4) demonstrate the use of the framework in vivo. An optimizing computational fluid dynamics solver including adjoint-based optimization was developed to fit computational fluid dynamics solutions to 4D-flow data. Synthetic tests were performed in 2D, and phantom validation was performed with pulsatile flow. Reference velocity data were acquired using particle imaging velocimetry, and 4D-flow data were acquired at 1.5 T. In vivo testing was performed on intracranial arteries in a healthy volunteer at 7 T, with 2D flow as the reference. Results Synthetic tests showed low error (0.4%-0.7%). Phantom validation showed improved agreement with laser particle imaging velocimetry compared with input 4D-flow in the horizontal (mean -0.05 vs -1.11 cm/s, P < .001; SD 1.86 vs 4.26 cm/s, P < .001) and vertical directions (mean 0.05 vs -0.04 cm/s, P = .29; SD 1.36 vs 3.95 cm/s, P < .001). In vivo data show a reduction in flow rate error from 14% to 3.5%. Phantom and in vivo results from 4D-flow HIKING show promise for future applications with higher resolution, shorter scan times, and accurate quantification of physiological parameters.

4D-flow MRI↗