Search NASA⌕ Search

SEARCH · Search NASA

Results for “VELOCITY MEASUREMENT”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 721 records · Page 40

Techniques for studying materials under extreme states of high energy density compression

The properties of materials under extreme conditions of pressure and density are of key interest to a number of fields, including planetary geophysics, materials science, and inertial confinement fusion. In geophysics, the equations of state of planetary materials, such as hydrogen and iron, under ultrahigh pressure and density provide a better understanding of their formation and interior structure [Celliers et al., “Insulator-metal transition in dense fluid deuterium,” Science 361, 677–682 (2018) and Smith et al., “Equation of state of iron under core conditions of large rocky exoplanets,” Nat. Astron. 2, 591–682 (2018)]. The processes of interest in these fields occur under conditions of high pressure (100 GPa–100 TPa), high temperature (>3000 K), and sometimes at high strain rates (>103 s−1) depending on the process. With the advent of high energy density (HED) facilities, such as the National Ignition Facility (NIF), Linear Coherent Light Source, Omega Laser Facility, and Z, these conditions are reachable and numerous experimental platforms have been developed. To measure compression under ultrahigh pressure, stepped targets are ramp-compressed and the sound velocity, measured by the velocity interferometer system for any reflector diagnostic technique, from which the stress-density of relevant materials is deduced at pulsed power [M. D. Knudson and M. P. Desjarlais, “High-precision shock wave measurements of deuterium: Evaluation of exchange-correlation functionals at the molecular-to-atomic transition,” Phys. Rev. Lett. 118, 035501 (2017)] and laser [Smith et al., “Equation of state of iron under core conditions of large rocky exoplanets,” Nat. Astron. 2, 591–682 (2018)] facilities. To measure strength under high pressure and strain rates, experimenters measure the growth of Rayleigh–Taylor instabilities using face-on radiography [Park et al., “Grain-size-independent plastic flow at ultrahigh pressures and strain rates,” Phys. Rev. Lett. 114, 065502 (2015)]. The crystal structure of materials under high compression is measured by dynamic x-ray diffraction [Rygg et al., “X-ray diffraction at the national ignition facility,” Rev. Sci. Instrum. 91, 043902 (2020) and McBride et al., “Phase transition lowering in dynamically compressed silicon,” Nat. Phys. 15, 89–94 (2019)]. Medium range material temperatures (a few thousand degrees) can be measured by extended x-ray absorption fine structure techniques, Yaakobi et al., “Extended x-ray absorption fine structure measurements of laser-shocked V and Ti and crystal phase transformation in Ti,” Phys. Rev. Lett. 92, 095504 (2004) and Ping et al., “Solid iron compressed up to 560 GPa,” Phys. Rev. Lett. 111, 065501 (2013), whereas more extreme temperatures are measured using x-ray Thomson scattering or pyrometry. This manuscript will review the scientific motivations, experimental techniques, and the regimes that can be probed for the study of materials under extreme HED conditions.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Deuterium velocity and temperature measurements on the DIII-D tokamak

Newly installed diagnostic capabilities on the DIII-D tokamak [J. L. Luxon, Nucl. Fusion 46, 6114 (2002)] enable the measurement of main ion (deuterium) velocity and temperature by charge exchange recombination spectroscopy. The uncertainty in atomic physics corrections for determining the velocity is overcome by exploiting the geometrical dependence of the apparent velocity on the viewing angle with respect to the neutral beam.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Direct-View Multi-Point Two-Component Interferometric Rayleigh Scattering Velocimeter

This paper describes an instantaneous velocity measurement system based on the Doppler shift of elastically scattered laser light from gas molecules (Rayleigh scattering) relative to an incident laser. The system uses a pulsed laser as the light source, direct-viewing optics to collect the scattered light, an interferometer to analyze spectrally the scattered light mixed with the incident laser light, and a CCD camera to capture the resulting interferogram. The system is capable of simultaneous, spatially (approximately 0.2 mm(exp 3)) and temporally (approximately 40 ns) resolved, multiple point measurements of two orthogonal components of flow velocity in the presence of background scattered light, acoustic noise and vibrations, and flow particulates. Measurements in a large-scale axi-symmetric Mach 1.6 H2-air combustion-heated jet running at a flow sensible enthalpy specific to Mach 5.5 hypersonic flight are performed to demonstrate the technique. The measurements are compared with CFD calculations using a finite-volume discretization of the Favre-averaged Navier-Stokes equations (VULCAN code).

Bivolaru, Daniel↗

Development of ultrasonic methods for hemodynamic measurements

A transcutanous method to measure instantaneous mean blood flow in peripheral arteries of the human body was defined. Transcutanous and implanted cuff ultrasound velocity measurements were evaluated, and the accuracies of velocity, flow, and diameter measurements were assessed for steady flow. Performance criteria were established for the pulsed Doppler velocity meter (PUDVM), and performance tests were conducted. Several improvements are suggested.

Histand, M. B.↗

Coherent Laser Instrument Would Measure Range and Velocity

A proposed instrument would project a narrow laser beam that would be frequency-modulated with a pseudorandom noise (PN) code for simultaneous measurement of range and velocity along the beam. The instrument performs these functions in a low mass, power, and volume package using a novel combination of established techniques. Originally intended as a low resource- footprint guidance sensor for descent and landing of small spacecraft onto Mars or small bodies (e.g., asteroids), the basic instrument concept also lends itself well to a similar application guiding aircraft (especially, small unmanned aircraft), and to such other applications as ranging of topographical features and measuring velocities of airborne light-scattering particles as wind indicators. Several key features of the instrument s design contribute to its favorable performance and resource-consumption characteristics. A laser beam is intrinsically much narrower (for the same exit aperture telescope or antenna) than a radar beam, eliminating the need to correct for the effect of sloping terrain over the beam width, as is the case with radar. Furthermore, the use of continuous-wave (CW), erbium-doped fiber lasers with excellent spectral purity (narrow line width) permits greater velocity resolution, while reducing the laser s power requirement compared to a more typical pulsed solid-state laser. The use of CW also takes proper advantage of the increased sensitivity of coherent detection, necessary in the first place for direct measurement of velocity using the Doppler effect. However, measuring range with a CW beam requires modulation to "tag" portions of it for time-of-flight determination; typically, the modulation consists of a PN code. A novel element of the instrument s design is the use of frequency modulation (FM) to accomplish both the PN-modulation and the Doppler-bias frequency shift necessary for signed velocity measurements. This permits the use of a single low-power waveguide electrooptic phase modulator, while simultaneously mitigating the effects of speckle as a noise source in the coherent detection.

Chang, Daniel↗

Additional measurements of pre-main-sequence stellar rotation

New rotational-velocity measurements for pre-main-sequence stars in the Taurus-Auriga molecular cloud are reported. Rotational velocities or upper limits of 10 km/s are now available for 90 percent of the T Tauri stars with V less than 14.7 in the catalog of Cohen and Kuhi. Measurements of 'continuum emission' stars, thought to be accreting high-angular-momentum material from a circumstellar disk, show that these objects are not especially rapid rotators. The results confirm earlier findings that angular-momentum loss proceeds very efficiently in the earliest stages of star formation, and suggest that stars older than about one million yr contract to the main sequence at nearly constant angular momentum. The slow rotation of T Tauri stars probably requires substantial angular-momentum loss via a magnetically coupled wind.

Hartmann, L.↗

Application of image cross-correlation to the measurement of glacier velocity using satellite image data

A high-resolution map of the velocity field of the central portion of Ice Stream E in West Antarctica, generated by the displacement-measuring technique, is presented. The use of cross-correlation software is found to be a significant improvement over previous manually based photogrammetric methods for velocity measurement, and is far more cost-effective than in situ methods in remote polar areas. A hue-intensity-saturation image of Ice Stream E and its velocity field is shown.

Scambos, Theodore A.↗

Time-Resolved In Situ Measurements During Rapid Alloy Solidification: Experimental Insight for Additive Manufacturing

In research and industrial environments, additive manufacturing (AM) of metals and alloys is becoming a pervasive technology, though significant challenges remain before widespread implementation of AM can be realized. In situ investigations of rapid alloy solidification with high spatial and temporal resolutions can provide unique experimental insight into microstructure evolution and kinetics that are relevant for AM processing. Hypoeutectic thin-film Al–Cu and Al–Si alloys were investigated using dynamic transmission electron microscopy to monitor pulsed-laser-induced rapid solidification across microsecond timescales. Solid–liquid interface velocities measured from time-resolved images revealed accelerating solidification fronts in both alloys. We observed microstructure evolution, solidification product, and presence of a morphological instability at the solid–liquid interface in the Al–4 at.%Cu alloy are related to the measured interface velocities and small differences in composition that affect the thermophysical properties of the alloys. These time-resolved in situ measurements can inform and validate predictive modeling efforts for AM.

36 MATERIALS SCIENCE↗

Field testing of a convergent array of acoustic Doppler profilers for high-resolution velocimetry in energetic tidal currents

An array of single-beam acoustic Doppler profilers has been developed for the high resolution measurement of three-dimensional tidal flow velocities and subsequently tested in an energetic tidal site. This configuration has been developed to increase spatial resolution of velocity measurements in comparison to conventional acoustic Doppler profilers (ADPs) which characteristically use divergent acoustic beams emanating from a single instrument. This is achieved using geometrically convergent acoustic beams creating a sample volume at the focal point of 0.03 m3. Away from the focal point, the array is also able to simultaneously reconstruct three-dimensional velocity components in a profile throughout the water column, and is referred to herein as a convergent-beam acoustic Doppler profiler (C-ADP). Mid-depth profiling is achieved through integration of the sensor platform with the operational commercial-scale Alstom 1MW DeepGen-IV Tidal Turbine deployed at the European Marine Energy Center, Orkney Isles, UK. This proof-of-concept paper outlines the C-ADP system configuration and comparison to measurements provided by co-installed reference instrumentation.

Harding, Samuel F.↗

Wind-tunnel studies of wing wake turbulence.

Description of velocity measurements made in the wake of wings in the Ames 7 x 10 ft wind tunnel. Distributions of velocity components were measured with a three-wire anemometer up to 12 chord lengths downstream of a CV-990 aircraft model and a rectangular wing. Results show that increasing the drag increases the vortex core radius, reduces the maximum tangential velocities, and increases the magnitude of axial velocity defects. For the rectangular wing, axial velocity changes from a defect (wake flow) for angles of attack less than 9 deg to an excess (jet flow) for angles of attack greater than 9 deg. Wind-tunnel measurements of the near flowfield are compared with flight measurements of the far flowfield.

Chigier, N. A.↗

Sap Velocity Data for Urban Trees in Chicago, Illinois (2024-2025)

This dataset contains uncorrected sap velocity measurements using the heat ratio method (HRM) collected using ICT International SFM1x sensors at five urban sites in Chicago, Illinois, as part of the DOE CROCUS project. The data includes continuous monitoring of sap velocity from various tree species, including Maples (Acer spp.): Sugar Maple (Acer saccharum), Silver Maple (Acer saccharinum), and Red Maple (Acer rubrum); Oaks (Quercus spp.): Swamp White Oak (Quercus bicolor); American Elm (Ulmus americana); Honey Locust (Gleditsia triacanthos); Cottonwood (Populus deltoides); and Tree of Heaven (Ailanthus altissima) across Chicago State University (CSU), Northeastern Illinois University (NEIU), Northwestern University (NU), University of Illinois Chicago (UIC), and West Woodlawn "Blacks in Green" (BIG). These include both street trees and those in urban park locations. Measurements were collected at 15-20 minute intervals, depending on the sensor, and transmitted via Long Range Wide Area Network (LoRaWAN) protocols. The wireless data was collected by Sage Network (https://sagecontinuum.org/) nodes. The dataset includes sensor ID, Global Positioning System (GPS) coordinates, tree species (common and scientific names), tree identification number, diameter at breast height (DBH in cm), uncorrected sap velocity measurements (cm/hr) from both inner and outer probes, and Sage Node identifiers so the data can be mapped to related variables such as air quality and wind speed that were collected on the Sage nodes. All timestamps are in local Chicago time (CDT/CST). Quality control flags are provided using a 3-bit binary system indicating physical range violations (< -10 or > 60 cm/hr), step spikes (absolute difference > 36 cm/hr), and stuck sensor conditions (> 10 consecutive identical values). These are raw data, not corrected for wood anatomy or species-specific characteristics. Data is provided in comma separated (CSV) format. This dataset is part of a larger collection of CROCUS environmental monitoring data, including linked datasets from Air Quality Transmitter (AQT) sensors, Weather Transmitter (WXT) sensors, and Multi-Function Research LoRaWAN (MFR) Nodes. DOIs for the supporting data are provided as part of this data package.

Chicago↗

Kinematic analysis of in situ measurement during chemical mechanical planarization process

Chemical mechanical planarization (CMP) is the most widely used planarization technique in semiconductor manufacturing presently. With the aid of in situ measurement technology, CMP tools can achieve good performance and stable productivity. However, the in situ measurement has remained unexplored from a kinematic standpoint. The available related resources for the kinematic analysis are very limited due to the complexity and technical secret. In this paper, a comprehensive kinematic analysis of in situ measurement is provided, including the analysis model, the measurement trajectory, and the measurement time of each zone of wafer surface during the practical CMP process. In addition, a lot of numerical calculations are performed to study the influences of main parameters on the measurement trajectory and the measurement velocity variation of the probe during the measurement process. All the efforts are expected to improve the in situ measurement system and promote the advancement in CMP control system.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Doppler systems.

Doppler tracking systems as velocity measuring systems, including introduction methods for necessary position knowledge, one- and two-way systems analyses, etc

RANGE AND RANGE RATE TRACKING↗

Dynamical constraints on the core mass of hot Jupiter HAT-P-13B

HAT-P-13b is a Jupiter-mass transiting exoplanet that has settled onto a stable, short-period, and mildly eccentric orbit as a consequence of the action of tidal dissipation and perturbations from a second, highly eccentric, outer companion. Owing to the special orbital configuration of the HAT-P-13 system, the magnitude of HAT-P-13b's eccentricity (e{sub b}) is in part dictated by its Love number (k{sub 2{sub b}}), which is in turn a proxy for the degree of central mass concentration in its interior. Thus, the measurement of e{sub b} constrains k{sub 2{sub b}} and allows us to place otherwise elusive constraints on the mass of HAT-P-13b's core (M{sub core,b}). In this study we derive new constraints on the value of e{sub b} by observing two secondary eclipses of HAT-P-13b with the Infrared Array Camera on board the Spitzer Space Telescope. We fit the measured secondary eclipse times simultaneously with radial velocity measurements and find that e{sub b} = 0.00700 ± 0.00100. We then use octupole-order secular perturbation theory to find the corresponding k{sub 2{sub b}}=0.31{sub −0.05}{sup +0.08}. Applying structural evolution models, we then find, with 68% confidence, that M{sub core,b} is less than 25 Earth masses (M{sub ⊕}). The most likely value is M{sub core,b} = 11 M{sub ⊕}, which is similar to the core mass theoretically required for runaway gas accretion. This is the tightest constraint to date on the core mass of a hot Jupiter. Additionally, we find that the measured secondary eclipse depths, which are in the 3.6 and 4.5 μm bands, best match atmospheric model predictions with a dayside temperature inversion and relatively efficient day–night circulation.

79 ASTRONOMY AND ASTROPHYSICS↗

Version 2 - Tidal Energy Resource Characterization, Velocity and Turbulence Measurements, Cook Inlet, AK, 2021

Version 2 of MHKDR submission #475, which also contains the metadata for these measurements. Files here are stored in netCDF4 format, which can be read in Python using the "netcdf4" or "xarray" packages or in MATLAB using the "ncread()" function. Changes are as follows: MWM1 (mid-water mooring 1) ADV - Time length of data now ends when bottom track data is lost - Improved filtering and quality control of bottom track measurements - improved motion correction of velocity - Improved Doppler noise subtraction - improved velocity, turbulent kinetic energy (TKE), Reynolds stress, time interval (TI), and dissipation rate estimations MWM1 Down-Looking ADCP - Improved filtering and quality control of bottom track measurements - improved motion correction of velocity - Improved Doppler noise subtraction - improved TI and dissipation rate estimations - Removed TKE calculations - accuracy could not be verified MWM1 Up-Looking ADCP - Improved Doppler noise subtraction - improved TI and dissipation rate estimations - Removed TKE calculations - accuracy could not be verified - Velocity unchanged MWM2 ADV - Removes data after instrument was hit by debris - Improved filtering and quality control of bottom track measurements - improved motion correction of velocity - Improved Doppler noise subtraction - improved velocity, TKE, Reynolds stress, TI, and dissipation rate estimations MWM2 Down-Looking ADCP - Improved filtering and quality control of bottom track measurements - improved motion correction of velocity - Improved Doppler noise subtraction - improved TI and dissipation rate estimations - Removed TKE calculations - accuracy could not be verified MWM2 Up-Looking ADCP - Improved filtering and quality control of bottom track measurements - improved motion correction of velocity - Improved Doppler noise subtraction - improved TI and dissipation rate estimations - Removed TKE calculations - accuracy could not be verified THEOM (bottom lander) ADV - Improved Doppler noise subtraction - improved TKE, Reynolds stress, TI, and dissipation rate estimations - Velocity unchanged THEOM ADCP (up-looking) - Improved Doppler noise subtraction - improved TKE, TI, and dissipation rate estimations - Removed vertical TKE component (w'w' bar) - Velocity unchanged

16 TIDAL AND WAVE POWER↗