Search NASA⌕ Search

SEARCH · Search NASA

Results for “accelerator diagnostics”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 721 records · Page 40

Particle Seeding Flow System for Horizontal Shock Tube

The Extreme Fluids Team in P-23, Physics Division, studies fluid dynamics at high speeds using high resolution diagnostics. The unsteady forces on a particle driven by a shock wave are not well understood, and they are difficult to model. A horizontal shock tube (HST) is being modified to collect data about the behavior of particles accelerated by shocks. The HST has been used previously for studies of Richtmyer-Meshkov instability using Planar Laser-Induced Fluorescence (PLIF) as well as Particle Image Velocimetry (PIV), diagnostics that measure density and velocity. The purpose of our project is to design a flow system that will introduce particles into the HST. The requirements for this particle flow system (PFS) are that it be non-intrusive, be able to introduce either solid or liquid particles, have an exhaust capability, not interfere with existing diagnostics, and couple with the existing HST components. In addition, the particles must flow through the tube in a uniform way. We met these design criteria by first drawing the existing shock tube and diagnostics and doing an initial design of the ducts for the PFS. We then estimated the losses through the particle flow system from friction and researched possible fans that could be used to drive the particles. Finally, the most challenging component of the design was the coupling to the HST. If we used large inlets, the shock would lose strength as it passed by the inlet, so we designed a novel coupling inlet and outlet that minimize the losses to the shock wave. Our design was reviewed by the Extreme Fluids Team, and it is now being manufactured and built based upon our technical drawings.

42 ENGINEERING↗

New Methods of Particle Collimation in Colliders

The collimation system is an essential part of the design of any high-power accelerator. Its functions include protection of components from accidental and intentional energy deposition, reduction of backgrounds, and beam diagnostics. Conventional multi-stage systems based on scatterers and absorbers offer robust shielding and efficient collection of losses. Two complementary concepts have been proposed to address some of the limitations of conventional systems: channeling and volume reflection in bent crystals and collimation with hollow electron beams. The main focus of this paper is the hollow electron beam collimator, a novel concept based on the interaction of the circulating beam with a 5-keV, magnetically confined, pulsed hollow electron beam in a 2-m-long section of the ring. The electrons enclose the circulating beam, kicking halo particles transversely and leaving the beam core unperturbed. By acting as tunable diffusion enhancer and not as a hard aperture limitation, the hollow electron beam collimator extends conventional collimation systems beyond the intensity limits imposed by tolerable losses. The concept was tested experimentally at the Fermilab Tevatron proton-antiproton collider. Results on the collimation of 980-GeV antiprotons are presented, together with prospects for the future.

43 PARTICLE ACCELERATORS↗

New Methods of Particle Collimation in Colliders

The collimation system is an essential part of the design of any high-power accelerator. Its functions include protection of components from accidental and intentional energy deposition, reduction of backgrounds, and beam diagnostics. Conventional multi-stage systems based on scatterers and absorbers offer robust shielding and efficient collection of losses. Two complementary concepts have been proposed to address some of the limitations of conventional systems: channeling and volume reflection in bent crystals and collimation with hollow electron beams. The main focus of this paper is the hollow electron beam collimator, a novel concept based on the interaction of the circulating beam with a 5-keV, magnetically confined, pulsed hollow electron beam in a 2-m-long section of the ring. The electrons enclose the circulating beam, kicking halo particles transversely and leaving the beam core unperturbed. By acting as a tunable diffusion enhancer and not as a hard aperture limitation, the hollow electron beam collimator extends conventional collimation systems beyond the intensity limits imposed by tolerable losses. The concept was tested experimentally at the Fermilab Tevatron proton-antiproton collider. Results on the collimation of 980-GeV antiprotons are presented, together with prospects for the future.

43 PARTICLE ACCELERATORS↗

Feedback Requirements for SASE-FELs

The operation of a Self Amplified Spontaneous Emission (SASE) Free Electron Lasers (FEL) at soft and hard X-ray wavelengths driven by a high brightness electron beam imposes strong requirements on the stability of the accelerator and feedback systems are necessary to both guarantee saturation of the SASE process as well as a stable photon beam for user experiments. Diagnostics for the relevant transverse and longitudinal beam parameters are presented and various examples of feedback systems for bunches with low repetition rate as well as systems for intra bunch train feedbacks are discussed.

43 PARTICLE ACCELERATORS↗

Spectroscopic measurement of ion temperature and ion velocity distributions in the flux-coil generated FRC

One aim of the flux-coil generated field reversed configuration at Tri Alpha Energy (TAE) is to establish the plasma where the ion rotational energy is greater than the ion thermal energy. To verify this, an optical diagnostic was developed to simultaneously measure the Doppler velocity-shift and line-broadening using a 0.75 m, 1800 groves/mm, spectrometer. The output spectrum is magnified and imaged onto a 16-channel photomultiplier tube (PMT) array. The individual PMT outputs are coupled to high-gain, high-frequency, transimpedance amplifiers, providing fast-time response. The Doppler spectroscopy measurements, along with a survey spectrometer and photodiode-light detector, form a suite of diagnostics that provide insights into the time evolution of the plasma-ion distribution and current when accelerated by an azimuthal-electric field.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Update on developments at SNIF

The Small Negative Ion Facility (SNIF) at CCFE has been undergoing continuous development and enhancement to both improve operational reliability and increase diagnostic capability. SNIF uses a CW 13.56MHz, 5kW RF driven volume source with a 30kV triode accelerator. Improvement and characterisation work includes: Installation of a new “L” type RF matching unit, used to calculate the load on the RF generator. Use of the electron suppressing biased insert as a Langmuir probe under different beam extraction conditions. Measurement of the hydrogen Fulcher molecular spectrum, used to calculate gas temperature in the source. Beam optimisation through parameter scans, using copper target plate and visible cameras, with results compared with AXCEL-INP to provide beam current estimate. Modelling of the beam power density profile on the target plate using ANSYS to estimate beam power and provide another estimate of beam current. This work is described, and has allowed an estimation of the extracted beam current of approximately 6mA (4mA/cm2) at 3.5kW RF power and a source pressure of 0.6Pa.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

SU-E-T-88: Comprehensive Automated Daily QA for Hypo- Fractionated Treatments

Purpose: The trend towards more SBRT treatments with fewer high dose fractions places increased importance on daily QA. Patient plan specific QA with 3%/3mm gamma analysis and daily output constancy checks may not be enough to guarantee the level of accuracy required for SBRT treatments. But increasing the already extensive amount of QA procedures that are required is a daunting proposition. We performed a feasibility study for more comprehensive automated daily QA that could improve the diagnostic capabilities of QA without increasing workload. Methods: We performed the study on a Siemens Artiste linear accelerator using the integrated flat panel EPID. We included square fields, a picket fence, overlap and representative IMRT fields to measure output, flatness, symmetry, beam center, and percent difference from the standard. We also imposed a set of machine errors: MLC leaf position, machine output, and beam steering to compare with the standard. Results: Daily output was consistent within +/− 1%. Change in steering current by 1.4% and 2.4% resulted in a 3.2% and 6.3% change in flatness. 1 and 2mm MLC leaf offset errors were visibly obvious in difference plots, but passed a 3%/3mm gamma analysis. A simple test of transmission in a picket fence can catch a leaf offset error of a single leaf by 1mm. The entire morning QA sequence is performed in less than 30 minutes and images are automatically analyzed. Conclusion: Automated QA procedures could be used to provide more comprehensive information about the machine with less time and human involvement. We have also shown that other simple tests are better able to catch MLC leaf position errors than a 3%/3mm gamma analysis commonly used for IMRT and modulated arc treatments. Finally, this information could be used to watch trends of the machine and predict problems before they lead to costly machine downtime.

60 APPLIED LIFE SCIENCES↗

Discoveries in Blast-Driven Turbulence of Astrophysical Relevance

The fluid mixing caused by variable-density instabilities is important in a wide variety of scenarios from ocean mixing and astrophysical phenomena to nuclear fusion techniques and atomic weapons. This thesis explores the mixing resulting from a specific instability known as the Blast Driven Instability (BDI). This work investigates the variable density mixing in an explosively driven environment due to the fluid instabilities at the material interfaces. Specifically, diverging Richtmyer-Meshkov (impulsive-acceleration environment) and Rayleigh-Taylor (variable-acceleration environment) instabilities (present in supernova and inertial confinement fusion) are studied using advanced high-speed diagnostics in carefully designed laboratory experiments. The BDI morphology is presented through a time development of Mie scattering images, and steps through the parameter space (varying density ratio and driver speed), highlighting the development of the structures that form during mixing. A scaling criterion is used to relate the two systems of vastly different spatiotemporal scales. Velocity fields in the BDI have been captured for the first time using the high temporal resolution PIV technique. Subsequent analysis of the dynamics of the instability from the velocity fields illustrates the distribution of kinetic energy, the transition to turbulence, and the characteristic growth of the instability are discussed. This study furthers understanding of how blast-driven instability pertains to supernova and inertial confinement fusion science. The morphology of the BDI has been characterized for the first time. This work steps through the parameter space covered in Mie scattering experiments, and how the different parameters contribute to development of structures and mixing. It also examines a scaling of the Atwood number for expanding predictive capabilities to other experimental conditions and simulations. The first collection of velocity fields acquired for the BDI are recorded, and subsequent analysis evaluating the distribution of kinetic energy throughout space and time for two density ratios from the overall parameter space, as well as the transition to turbulence, estimated from a Reynolds number calculated based on momentum mixing are all presented. This information is useful in advancing the development of models to predict physics of high energy density applications where experiments are not always readily available. This research has successfully demonstrated understanding for the time criteria defining regimes where the shock driven (Richtmyer-Meshkov instability) and the buoyancy driven (Rayleigh-Taylor instability) dominates through a parametric study of density variation (Atwood number) and driver speed (Mach number). All this furthers understanding of how the BDI pertains to SN and ICF.

79 ASTRONOMY AND ASTROPHYSICS↗

A critical examination of expansion tunnel performance

An experimental study of the performance of the expansion tunnel for various test gases and range of quiescent acceleration section and nozzle pressure, nozzle geometric area ratio, and nozzle axial station has been performed. Flow diagnostics used to examine expansion tunnel flow characteristics were time histories and profiles of pitot pressure and axial component of flow velocity. The purpose of this study was to determine experimentally what limitations might restrict predicted operational flexibility and the advantages and disadvantages of this mode of operation as compared to the expansion tube. Results are presented which demonstrate the expansion tunnel offers several advantages over the expansion tube, but the severity of the disadvantages of the tunnel makes the expansion tube mode of operation the more desirable for performing hypersonic-hypervelocity aerothermodynamic studies of proposed entry configurations.

Miller, C. G.↗

The Spacelab Lyman alpha and white light coronagraphs program

The Harvard-Smithsonian Center for Astrophysics and the High Altitude Observatory have defined a joint coronagraphs experiment for a future Spacelab mission. The instrumentation package would include an ultraviolet light coronagraph to measure the intensity and profiles of spectral lines formed between 1.2 and 8 solar radii from sun center and a white light coronagraph to measure the intensity and polarization of visible light. The overall goals of the joint program are to use new coronal plasma diagnostic techniques to understand the physical processes and mechanisms operating in the solar corona, to understand the acceleration of high-speed and low-speed solar wind streams and to extrapolate this knowledge to other stars in order to help understand the physics of stellar coronae and stellar mass loss.

Kohl, J. L.↗

Highly Structured Slow Solar Wind Emerging From an Equatorial Coronal Hole

At solar minimum, the solar wind is observed at high solar latitudes as a predominantly fast (> 500 km/s), highly Alfvenic, rarefied stream of plasma originating deep within coronal holes, while near the ecliptic plane it is interspersed with a more variable slow (< 500 kms) wind. The precise origins of the slow wind streams are less certain, with theories and observations supporting sources from the tips of helmet streamers, interchange reconnection near coronal hole boundaries, and origins within coronal holes with highly diverging magnetic fields. The heating mechanism required to drive the solar wind is also an open question and candidate mechanisms include Alfven wave turbulence, heating by reconnection in nanoflares, ion cyclotron wave heating and acceleration by thermal gradients1. At 1 au, the wind is mixed and evolved and much of the diagnostic structure of these sources and processes has been lost. Here we present new measurements from Parker Solar Probe at 36 to 54 solar radii that show clear evidence of slow, Alfvenic solar wind emerging from a small equatorial coronal hole. The measured magnetic field exhibits patches of large, intermittent reversals associated with jets of plasma and enhanced Poynting flux and interspersed in a smoother and less turbulent flow with near-radial magnetic field. Furthermore, plasma wave measurements suggest electron and ion velocity-space micro-instabilities that have been identified with plasma heating and thermalization processes. Our measurements suggest an impulsive mechanism associated with solar wind energization and a heating role for micro-instabilities and provide strong evidence for low latitude coronal holes as a significant contribution to the source of the slow solar wind.

Solar physics↗

Diagnostics for ion beam driven high energy density physics experiments

Intense beams of heavy ions are capable of heating volumetric samples of matter to high energy density. Experiments are performed on the resulting warm dense matter (WDM) at the NDCX-I ion beam accelerator. The 0.3 MeV, 30 mA K{sup +} beam from NDCX-I heats foil targets by combined longitudinal and transverse neutralized drift compression of the ion beam. Both the compressed and uncompressed parts of the NDCX-I beam heat targets. The exotic state of matter (WDM) in these experiments requires specialized diagnostic techniques. We have developed a target chamber and fielded target diagnostics including a fast multichannel optical pyrometer, optical streak camera, laser Doppler-shift interferometer (Velocity Interferometer System for Any Reflector), beam transmission diagnostics, and high-speed gated cameras. We also present plans and opportunities for diagnostic development and a new target chamber for NDCX-II.

43 PARTICLE ACCELERATORS↗

Magneto-optical measurement of magnetic field and electrical current on a short pulse high energy pulsed power accelerator

We describe a direct magneto-optical approach to measuring the magnetic field driven by a narrow pulse width (<10 ns), 20 kA electrical current flow in the transmission line of a high energy pulsed power accelerator. The magnetic field and electrical current are among the most important operating parameters in a pulsed power accelerator and are critical to understanding the properties of the radiation output. However, accurately measuring these fields and electrical currents using conventional pulsed power diagnostics is difficult due to the strength of ionizing radiation and electromagnetic interference. Our approach uses a fiber coupled laser beam with a rare earth element sensing crystal sensor that is highly resistant to electromagnetic interference and does not require external calibration. Here, we focus on device theory, operating parameters, results from an experiment on a high energy pulsed power accelerator, and comparison to a conventional electrical current shunt sensor.

42 ENGINEERING↗

3D Modeling of the ALICE Photoinjector Upgrade

The injector for the ALICE machine (Accelerators and Lasers In Combined Experiments) at Daresbury Laboratory is based around a 350 kV DC photocathode electron gun. An upgrade is proposed to introduce a load-lock GaAs photocathode preparation facility to allow rapid transfer of photocathodes to the gun without breaking the vacuum system. In the current design this requires side-loading of the photocathodes into the cathode ball. An alternative is to relocate the ceramic insulator vertically which will allow back-loading and also backillumination of the photocathodes. 3D electrostatic simulations of the gun chamber are presented for both options along with 3D beam dynamic simulations for an off-axis photocathode, introduced to increase photocathode lifetime by reducing damage by ion backbombardment. Beam dynamic simulations are also presented for the entire injector beamline as well as for a proposed extension to the injector beamline to include a diagnostic section.

43 PARTICLE ACCELERATORS↗

Beam Measurement of 11.424 GHz X-Band Linac for Compton Scattering X-ray Source

An inverse Compton scattering X-ray source for medical applications, consisting of an X-band (11.424 GHz) linac and Q-switched Nd:YAG laser, is currently being developed at the University of Tokyo. This system uses an X-band 3.5-cell thermionic cathode RF gun for electron beam generation. We can obtain a multi-bunch electron beam with this gun. The beam is accelerated to 30 MeV by a traveling-wave accelerating tube. So far, we have verified stable beam generation (around 2.3 MeV) by using the newly designed RF gun and we have succeeded in beam transportation to a beam dump.

43 PARTICLE ACCELERATORS↗

Laser Wakefield Accelerator modelling with Variational Neural Networks

A machine learning model was created to predict the electron spectrum generated by a GeV-class laser wakefield accelerator. The model was constructed from variational convolutional neural networks, which mapped the results of secondary laser and plasma diagnostics to the generated electron spectrum. An ensemble of trained networks was used to predict the electron spectrum and to provide an estimation of the uncertainty of that prediction. It is anticipated that this approach will be useful for inferring the electron spectrum prior to undergoing any process that can alter or destroy the beam. In addition, the model provides insight into the scaling of electron beam properties due to stochastic fluctuations in the laser energy and plasma electron density.

43 PARTICLE ACCELERATORS↗

Mach-Zehnder recording systems for pulsed power diagnostics

Fiber-optic transmission and recording systems, based on Mach-Zehnder modulators, have been developed and installed at the National Ignition Facility (NIF), and are being developed for other pulsed-power facilities such as the Z accelerator at Sandia, with different requirements. We present the design and performance characteristics for the mature analog links, based on the system developed for the Gamma Reaction History diagnostic at the OMEGA laser and at NIF. For a single detector channel, two Mach-Zehnders are used to provide high dynamic range at the full recording bandwidth with no gaps in the coverage. We present laboratory and shot data to estimate upper limits on the radiation effects as they impact recorded data quality. Finally, we will assess the technology readiness level for mature and developing implementations of Mach-Zehnder links for these environments.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Experimental validation of a radio frequency photogun as external electron injector for a laser wakefield accelerator

A purpose-built RF-photogun as external electron injector for a laser wakefield accelerator has been thoroughly tested. Different properties of the RF-photogun have been measured such as energy, energy spread and transverse emittance. The focus of this study is the investigation of the smallest possible focus spot and focus stability at the entrance of the plasma channel. For an electron bunch with 10 pC charge and 3.7 MeV kinetic energy, the energy spread was 0.5% with a shot-to-shot stability of 0.05%. After focusing the bunch by a pulsed solenoid lens at 140 mm from the middle of the lens, the focal spot was 40 {mu}m with a shot-to-shot stability of 5 {mu}m. Higher charge leads to higher energy spread and to a larger spot size, due to space charge effects. All properties were found to be close to design values. Given the limited energy of 3.7 MeV, the properties are sufficient for this gun to serve as injector for one particular version of laser wakefield acceleration, i.e., injection ahead of the laser pulse. These measured electron bunch properties were then used as input parameters for simulations of electron bunch injection in a laser wakefield accelerator. The arrival time jitter was deduced from measurements of the energy fluctuation, in combination with earlier measurements using THz coherent transition radiation, and is around 150 fs in the present setup. The bunch length in the focus, simulated using particle tracking, depends on the accelerated charge and goes from 100 fs at 0.1 pC to 1 ps at 50 pC. When simulating the injection of the 3.7 MeV electron bunch of 10 pC in front of a 25 TW laser pulse with a waist of 30 {mu}m in a plasma with a density of 0.7 x 10{sup 24} m{sup -3}, the maximum accelerated charge was found to be 1.2 pC with a kinetic energy of {approx}900 MeV and an energy spread of {approx}5%. The experiments combined with the simulations show the feasibility of external injection and give a prediction of the output parameters that can be expected from a laser wakefield accelerator with external injection of electrons.

43 PARTICLE ACCELERATORS↗