Search NASA⌕ Search

SEARCH · Search NASA

Results for “acceptance angle”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 721 records · Page 40

Design and Construction of a High-Resolution Hodoscope for the GlueX Experiment with High-Statistics Analysis of the p0, ¿, and ¿1 Photoproduction Cross Sections from the RadPhi Experiment

Differential cross sections for forward-angle photoproduction of p0, ¿, and ¿ 1 pseudoscalar mesons were measured using data from the RadPhi experiment conducted in Hall B at Jef ferson Lab. RadPhi utilized a tagged bremsstrahlung photon beam incident on a stationary 9Be target, with a detector system configured to trigger on a recoil proton in coincidence with multiple neutral showers in the calorimeter. Events were reconstructed and subjected to kinematic constraints, with background suppressed via sideband subtraction guided by Monte Carlo modeling of background contributions. Cross sections were extracted over the photon energy range 4.4– 5.4 GeV and binned in invariant momentum transfer t, providing measurements from one of the first high-statistics experiments of forward ¿ and ¿1 pro duction from a nuclear target at these energies. Acceptance corrections were applied using a detailed GEANT-based simulation of the detector geometry and response. The resulting cross sections are consistent with 2020 CLAS results, when scaled by the number of protons in beryllium, and show broad agreement with other data and theoretical models. In parallel, a high-resolution photon tagger detector, the Tagger Microscope (TAGM), was designed, constructed, and commissioned for the GlueX experiment in Hall D at Jefferson Lab. The TAGM was developed to provide high-rate tagging capability in the coherent bremsstrahlung peak by detecting post-bremsstrahlung electrons across a one GeV range along the focal plane of the tagging spectrometer. The detector consists of a 5ˆ102 array of 2ˆ2 mm2 square BCF-20 plastic scintillating fibers thermally fused to BCF-98 light guide fibers optically coupled to silicon photomultipliers. These fibers are mounted in a precision machined framework enabling fine positional adjustments to maintain precise alignment with post-bremsstrahlung electron trajectories, while ensuring mechanical rigidity, thermal stability, optical isolation, minimal inactive area, and radiation shielding for electronics. The construction effort involved extensive testing of fiber quality, light transmission, thermal fusing, radiation hardness, and defect analysis using SEM and EDX techniques. Following its installation and commissioning, the TAGM became a critical component of the GlueX beamline, enabling high-rate tagging essential for studies of hybrid mesons and gluonic ex citations.

McIntyre, James [Univ. of Connecticut, Storrs, CT ↗

Strain energy-based fatigue failure analyses of LB-PBF Inconel 718: Effect of build orientation

Additively manufactured Inconel 718 parts fabricated in three build orientations (horizontal, vertical, and angled at 45 degrees) are tested in fully-reversed bending fatigue mode. Damping measurements via the Impulse Excitation technique are used to assess the defects content in the microstructure and fractography analysis is performed to detect the root cause of failure. Two micro- and macro-scale methodologies of fatigue damage estimation based on the dissipated heat per cycle and the statistical estimation of micro-plastic strain energies are used to assess fatigue damage. It is shown that at a given stress level, the vertically built specimens endure the most fatigue damage before failure while the diagonally built ones sustain the least. As a result, the fatigue life is estimated for arbitrary load amplitudes via a microstructure-sensitive algorithm with acceptable accuracy as compared to the experiments.

36 MATERIALS SCIENCE↗

A piloted evaluation of an oblique-wing research aircraft motion simulation with decoupling control laws

The NASA Ames Research Center developed an oblique-wing research plane from NASA's digital fly-by-wire airplane. Oblique-wing airplanes show large cross-coupling in control and dynamic behavior which is not present on conventional symmetric airplanes and must be compensated for to obtain acceptable handling qualities. The large vertical motion simulator at NASA Ames-Moffett was used in the piloted evaluation of a proposed flight control system designed to provide decoupled handling qualities. Five discrete flight conditions were evaluated ranging from low altitude subsonic Mach numbers to moderate altitude supersonic Mach numbers. The flight control system was effective in generally decoupling the airplane. However, all participating pilots objected to the high levels of lateral acceleration encountered in pitch maneuvers. In addition, the pilots were more critical of left turns (in the direction of the trailing wingtip when skewed) than they were of right turns due to the tendency to be rolled into the left turns and out of the right turns. Asymmetric side force as a function of angle of attack was the primary cause of lateral acceleration in pitch. Along with the lateral acceleration in pitch, variation of rolling and yawing moments as functions of angle of attack caused the tendency to roll into left turns and out of right turns.

Kempel, Robert W.↗

Validation Analysis of the Shoal Groundwater Flow and Transport Model

Environmental restoration at the Shoal underground nuclear test is following a process prescribed by a Federal Facility Agreement and Consent Order (FFACO) between the U.S. Department of Energy, the U.S. Department of Defense, and the State of Nevada. Characterization of the site included two stages of well drilling and testing in 1996 and 1999, and development and revision of numerical models of groundwater flow and radionuclide transport. Agreement on a contaminant boundary for the site and a corrective action plan was reached in 2006. Later that same year, three wells were installed for the purposes of model validation and site monitoring. The FFACO prescribes a five-year proof-of-concept period for demonstrating that the site groundwater model is capable of producing meaningful results with an acceptable level of uncertainty. The corrective action plan specifies a rigorous seven step validation process. The accepted groundwater model is evaluated using that process in light of the newly acquired data. The conceptual model of ground water flow for the Project Shoal Area considers groundwater flow through the fractured granite aquifer comprising the Sand Springs Range. Water enters the system by the infiltration of precipitation directly on the surface of the mountain range. Groundwater leaves the granite aquifer by flowing into alluvial deposits in the adjacent basins of Fourmile Flat and Fairview Valley. A groundwater divide is interpreted as coinciding with the western portion of the Sand Springs Range, west of the underground nuclear test, preventing flow from the test into Fourmile Flat. A very low conductivity shear zone east of the nuclear test roughly parallels the divide. The presence of these lateral boundaries, coupled with a regional discharge area to the northeast, is interpreted in the model as causing groundwater from the site to flow in a northeastward direction into Fairview Valley. Steady-state flow conditions are assumed given the absence of groundwater withdrawal activities in the area. The conceptual and numerical models were developed based upon regional hydrogeologic investigations conducted in the 1960s, site characterization investigations (including ten wells and various geophysical and geologic studies) at Shoal itself prior to and immediately after the test, and two site characterization campaigns in the 1990s for environmental restoration purposes (including eight wells and a year-long tracer test). The new wells are denoted MV-1, MV-2, and MV-3, and are located to the northnortheast of the nuclear test. The groundwater model was generally lacking data in the north-northeastern area; only HC-1 and the abandoned PM-2 wells existed in this area. The wells provide data on fracture orientation and frequency, water levels, hydraulic conductivity, and water chemistry for comparison with the groundwater model. A total of 12 real-number validation targets were available for the validation analysis, including five values of hydraulic head, three hydraulic conductivity measurements, three hydraulic gradient values, and one angle value for the lateral gradient in radians. In addition, the fracture dip and orientation data provide comparisons to the distributions used in the model and radiochemistry is available for comparison to model output. Goodness-of-fit analysis indicates that some of the model realizations correspond well with the newly acquired conductivity, head, and gradient data, while others do not. Other tests indicated that additional model realizations may be needed to test if the model input distributions need refinement to improve model performance. This approach (generating additional realizations) was not followed because it was realized that there was a temporal component to the data disconnect: the new head measurements are on the high side of the model distributions, but the heads at the original calibration locations themselves have also increased over time. This indicates that the steady-state assumption of the groundwater model is in error. To test the robustness of the model despite the transient nature of the heads, the newly acquired MV hydraulic head values were trended back to their likely values in 1999, the date of the calibration measurements. Additional statistical tests are performed using both the backward-projected MV heads and the observed heads to identify acceptable model realizations. A jackknife approach identified two possible threshold values to consider. For the analysis using the backward-trended heads, either 458 or 818 realizations (out of 1,000) are found acceptable, depending on the threshold chosen. The analysis using the observed heads found either 284 or 709 realizations acceptable. The impact of the refined set of realizations on the contaminant boundary was explored using an assumed starting mass of a single radionuclide and the acceptable realizations from the backward-trended analysis.

54 ENVIRONMENTAL SCIENCES↗

Processing GPS Occultation Data To Characterize Atmosphere

GOAS [Global Positioning System (GPS) Occultation Analysis System] is a computer program that accepts signal-occultation data from GPS receivers aboard low-Earth-orbiting satellites and processes the data to characterize the terrestrial atmosphere and, in somewhat less comprehensive fashion, the ionosphere. GOAS is very robust and can be run in an unattended semi-operational processing mode. It features sophisticated retrieval algorithms that utilize the amplitudes and phases of the GPS signals. It incorporates a module that, using an assumed atmospheric refractivity profile, simulates the effects of the retrieval processing system, including the GPS receiver. GOAS utilizes the GIPSY software for precise determination of orbits as needed for calibration. The GOAS output for the Earth s troposphere and mid-to-lower stratosphere consists of high-resolution (<1 km) profiles of density, temperature, pressure, atmospheric refractivity, bending angles of signals, and water-vapor content versus altitude from the Earth s surface to an altitude of 30 km. The GOAS output for the ionosphere consists of electron-density profiles from an altitude of about 50 km to the altitude of a satellite, plus parameters related to the rapidly varying structure of the electron density, particularly in the E layer of the ionosphere.

Hajj, George↗

Numerical investigation of the effects of icing on fixed and rotary wing aircraft

A 2-D multi-element airfoil code was modified to study the effects of icing on the aerodynamic characteristics of high lift systems. In each zone of the flow field, the solver numerically integrates the 2-D compressible Navier-Stokes equations using a time marching scheme. The surface pressure distribution is generated over a GAW 130 airfoil/flap combination for a flap setting of 25 degrees, and an angle of attack equal to 5 degrees, at a freestream Mach number equal to 0.3. A series of calculations were performed to determine the effects of small scale ice build up on the high lift characteristics of this arifoil/flap combination. The appendix summarizes this progress. Joint studies on correlation of a 3-D iced wing code with experimental data reviewed new measured laser Doppler velocimeter data in the separated region behind the leading edge ice shape. A version of the iced wing analysis using the Roe scheme was developed to evaluate the poor correlation between the computed and measured velocities in the separated region. Work on the extension of the wing-alone analysis to wing body configuration began with modifications to the 3-D iced wing analyses to accept externally generated grids and multi-block grids.

Sankar, L. N.↗

Hubble Space Telescope Fine Guidance Sensor and Two-Gyro Control Law Design, Implementation, and On-Orbit Performance

For fifteen years, the science mission of the Hubble Space Telescope (HST) required using at least three rate gyros for n Controlling with alternate sensors to replace failing gyros can extend the HST science mission. A two-gyro control law has been designed and implemented using magnetometers, star trackers, and Fine Guidance Sensors (FGSs) to control vehicle rate about the missing gyro axis. The three aforementioned sensors are used in succession to reduce HST boresight jitter to less than 7 milli-arcseconds rms prior to science imaging. The Magnetometer and 2-Gyro (M2G) control law is used for large angle maneuvers and attitude control during earth. occultation of star trackers and FGSs. The Tracker and 2-Gyro (T2G) control law dampens M2G rates and controls attitude in preparation for guide star acquisition with the FGSs. The Fine Guidance Sensor and 2-Gyro (F2G) control law dampens T2G rates and controls HST attitude during science imaging. This paper describes the F2G control law. Details of F2G algorithms are presented, including computation of the FGS-measured star vector using non-linear equations, optimal estimation of HST body rate, design of the F2G control laws and gyro bias observer, SISO and MIMO linear stability analyses, and design of the F2G intramode transition and guide star acquisition logic. Results from an FGS flight spare ground test are presented that define acceptable HST jitter levels for successful guide star acquisition under two-gyro control. HST-specific disturbance and noise models are described that are based upon flight telemetry; these models are used in HSTSIM, a high-fidelity non-linear time domain simulation, to predict HST on-orbit disturbance responses and FGS interferometer Loss of Lock (LOL) characteristics under F2G control. Additional HSTSIM results are presented predicting HST quiescent boresight jitter performance, science maneuver performance, and observer configuration performance during F2G operation. Simulation results are compared to on-orbit data b m F2G flight tests performed in February 2005. Science images and point spread functions from the Advanced Camera for Surveys (ACS) High Resolution Camera (HRC) are presented that compare HST science performance under F2G versus three-gyro control. Images and flight telemetry show that HST boresight jitter with the new F2G control law is usually less than jitter using the three-gyro law, and HST boresight jitter during F2G operation is dependent upon guide star magnitude.

Clapp, Brian R.↗

Advanced Variance Reduction for Global k-Eigenvalue Simulations in MCNP

The "criticality" or k-eigenvalue of a nuclear system determines whether the system is critical (k=1), or the extent to which it is subcritical (k<1) or supercritical (k>1). Calculations of k are frequently performed at nuclear facilities to determine the criticality of nuclear reactor cores, spent nuclear fuel storage casks, and other fissile systems. These calculations can be expensive, and current Monte Carlo methods have certain well-known deficiencies. In this project, we have developed and tested a new "functional Monte Carlo" (FMC) method that overcomes several of these deficiencies. The current state-of-the-art Monte Carlo k-eigenvalue method estimates the fission source for a sequence of fission generations (cycles), during each of which M particles per cycle are processed. After a series of "inactive" cycles during which the fission source "converges," a series of "active" cycles are performed. For each active cycle, the eigenvalue and eigenfunction are estimated; after N >> 1 active cycles are performed, the results are averaged to obtain estimates of the eigenvalue and eigenfunction and their standard deviations. This method has several disadvantages: (i) the estimate of k depends on the number M of particles per cycle, (iii) for optically thick systems, the eigenfunction estimate may not converge due to undersampling of the fission source, and (iii) since the fission source in any cycle depends on the estimated fission source from the previous cycle (the fission sources in different cycles are correlated), the estimated variance in k is smaller than the real variance. For an acceptably large number M of particles per cycle, the estimate of k is nearly independent of M; this essentially takes care of item (i). Item (ii) can be addressed by taking M sufficiently large, but for optically thick systems a sufficiently large M can easily be unrealistic. Item (iii) cannot be accounted for by taking M or N sufficiently large; it is an inherent deficiency due to the correlations between fission source estimates. In the new FMC method, the eigenvalue problem (expressed in terms of the Boltzmann equation) is integrated over the energy and direction variables. Then these equations are multiplied by J special "tent" functions in space and integrated over the spatial variable. This yields J equations that are exactly satisfied by the eigenvalue k and J space-angle-energy moments of the eigenfunction. Multiplying and dividing by suitable integrals of the eigenfunction, one obtains J algebraic equations for k and the space-angle-energy moments of the eigenfunction, which contain nonlinear functionals that depend weakly on the eigenfunction. In the FMC method, information from the standard Monte Carlo solution for each active cycle is used to estimate the functionals, and at the end of each cycle the J equations for k and the space-angle-energy moments of the eigenfunction are solved. Finally, these results are averaged over N active cycles to obtain estimated means and standard deviations for k and the space-angle-energy moments of the eigenfunction. Our limited testing shows that for large single fissile systems such as a commercial reactor core, (i) the FMC estimate of the eigenvalue is at least one order of magnitude more accurate than estimates obtained from the standard Monte Carlo approach, (ii) the FMC estimate of the eigenfunction converges and is several orders of magnitude more accurate than the standard estimate, and (iii) the FMC estimate of the standard deviation in k is at least one order of magnitude closer to the correct standard deviation than the standard estimate. These advances occur because: (i) the Monte Carlo estimates of the nonlinear functionals are much more accurate than the direct Monte Carlo estimates of the eigenfunction, (ii) the system of discrete equations that determines the FMC estimates of k is robust, and (iii) the functionals are only very weakly correlated between different fission generations. The FMC method was developed only late in the project and has to date received limited testing. Current work, which is taking place after the conclusion of this project, involves further development and testing for more complex and realistic problems. We expect that the FMC method will become a practical tool for Monte Carlo criticality simulations.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Wind tunnel test of a variable-diameter tiltrotor (VDTR) model

This report documents the results from a wind tunnel test of a 1/6th scale Variable Diameter Tiltrotor (VDTR). This test was a joint effort of NASA Ames and Sikorsky Aircraft. The objective was to evaluate the aeroelastic and performance characteristics of the VDTR in conversion, hover, and cruise. The rotor diameter and nacelle angle of the model were remotely changed to represent tiltrotor operating conditions. Data is presented showing the propulsive force required in conversion, blade loads, angle of attack stability and simulated gust response, and hover and cruise performance. This test represents the first wind tunnel test of a variable diameter rotor applied to a tiltrotor concept. The results confirm some of the potential advantages of the VDTR and establish the variable diameter rotor a viable candidate for an advanced tiltrotor. This wind tunnel test successfully demonstrated the feasibility of the Variable Diameter rotor for tilt rotor aircraft. A wide range of test points were taken in hover, conversion, and cruise modes. The concept was shown to have a number of advantages over conventional tiltrotors such as reduced hover downwash with lower disk loading and significantly reduced longitudinal gust response in cruise. In the conversion regime, a high propulsive force was demonstrated for sustained flight with acceptable blade loads. The VDTR demonstrated excellent gust response capabilities. The horizontal gust response correlated well with predictions revealing only half the response to turbulence of the conventional civil tiltrotor.

Matuska, David↗

Flow, Noise and Thrust of Supersonic Plug Nozzles

A model-scale experimental study is conducted with a plug nozzle exploring the performance of various plug geometries for supersonic aircraft concepts. All data are acquired with a given outer nozzle that is convergent and has an exit diameter of 2 inches. The shape of the centrally placed plug is varied from conic with various half-angles (lengths), to method of characteristics (MoC) designs, as well as truncated and porous geometries. Noise and schlieren flow visualization data, presented in an earlier paper, are briefly reviewed first. The focus in this paper is on the thrust performance. A newly constructed thrust stand is used to acquire data covering a nozzle pressure ratio (NPR) range from transonic (‘landing and takeoff’, LTO) to supersonic (‘cruise’) conditions. Back-to-back measurements allowed assessment of relative performance. A plug with its ‘crown’ located somewhat inside the nozzle, rather than near the exit, is found to perform better. A longer 10° plug performs better than a shorter 22° plug. A porous plug, that significantly suppresses broadband shock associated noise, is found to incur a modest thrust loss that might be an acceptable tradeoff near LTO conditions. A companion numerical simulation for some of the plug geometries yields data trends bearing reasonable agreement with the experimental results.

jets↗

Acoustic Testing of the Joby Aviation Propeller in the National Full-Scale Aerodynamics Complex 40- by 80-Foot Wind Tunnel

The advanced air mobility sector has progressed in recent years with electric vertical take-Off and landing vehicles at the forefront. In response, the NASA Advanced Air Mobility Project has initiated the Advanced Air Mobility National Campaign to partner with industry to progress this emerging market. This resulted in NASA’s Revolutionary Vertical Lift Technology project to participate to progress research efforts for software tool validation for these advanced air mobility vehicle configurations. Noise has been identified as one of the main obstacles to succeeding in this emerging market for community acceptance. To further understand electric vertical take-Off and landing vehicle noise, an isolated Joby Aviation S4 propeller was tested in the National Full-Scale Aerodynamics Complex 40- by 80-Foot Wind Tunnel to aid in providing high quality performance, loads, and acoustic data. Details of test hardware and setup are described with a focus on acoustics, which includes facility, test model, microphone locations, and data acquisition system details. Additionally, the data processing techniques and completed test matrix for acoustic points are provided. To aid in identifying potential acoustic reflections, an acoustic reflection test was performed prior to the start of the test and highlighted the presence of reflections at every microphone location. Acoustic results are provided for various flight regimes for sweeps of blade pitch, RPM, flow angle, and wind speed. These results show an optimum RPM for a specific thrust level for noise, and further reductions in RPM can increase noise levels. This dataset will be used to evaluate and improve computational tools.

Aviation Propeller↗

Potential annual daylighting performance of a high-efficiency daylight redirecting slat system

While the primary role of window attachments is often to moderate glare and solar heat gains, they are also able to provide additional daylight to interior spaces. For this purpose, a variety of daylight-redirecting window systems have been developed over the past 150 years. Fixed reflective systems (slats/light shelves) or prismatic systems that rely on total internal reflection work well under specific solar conditions, but generally sacrifice performance over a much wider range of incident solar angles and sky conditions. Dynamic systems - typically reflective slats - are more responsive to sun angles but have not been able to achieve optimal performance for glare and daylight redirection efficiency. A previous investigation into an adjustable, reflective blind concept first conceived of in the late 1970s showed promise but was not reduced to practice due to lack of adequate simulation and analysis tools. In this paper, this concept is further developed and its energy and visual comfort performance evaluated for four mid-latitude, temperate climates using ray-tracing simulation techniques. Overall, results indicate significant potential lighting energy savings when compared with conventional automated reflective blinds (2.1–4.9 kWh/(m 2 ·a), or 14%–42%, depending on climate and orientation) or, especially, manually-operated matte white venetian blinds (1.4–7.9 kWh/(m 2 ·a), or 9%–54%, depending on climate and orientation), while maintaining acceptable or better visual comfort conditions throughout the interior space.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Robust adaptive kinematic control of redundant robots

The paper presents a general method for the resolution of redundancy that combines the Jacobian pseudoinverse and augmentation approaches. A direct adaptive control scheme is developed to generate joint angle trajectories for achieving desired end-effector motion as well as additional user defined tasks. The scheme ensures arbitrarily small errors between the desired and the actual motion of the manipulator. Explicit bounds on the errors are established that are directly related to the mismatch between actual and estimated pseudoinverse Jacobian matrix, motion velocity and the controller gain. It is shown that the scheme is tolerant of the mismatch and consequently only infrequent pseudoinverse computations are needed during a typical robot motion. As a result, the scheme is computationally fast, and can be implemented for real-time control of redundant robots. A method is incorporated to cope with the robot singularities allowing the manipulator to get very close or even pass through a singularity while maintaining a good tracking performance and acceptable joint velocities. Computer simulations and experimental results are provided in support of the theoretical developments.

Tarokh, M.↗

Neurophysiological study on visuo-vestibular control of posture and movement in fish during adaptation to weightlessness

We can stand upright and walk smoothly without paying any particular attention to it. This is because we have established in ourselves an integration center that controls our body subconsciously in response to input from eyes, muscles, joints, foot soles, and also from the gravity sensor in the inner ear (the otolith organ). It has been shown that the cerebellum plays an important role for the establishment of the integration center and that the control pattern is comparable to that of a highly sophisticated computer system. The programming for the control, however, may well be acquired for the 1-g ground condition and does not cover the 0-g in space. Although each of the above organs function as it does on the ground, the signal pattern sent to the center must be different under 0-g and, in addition, complementary signals from the otolith organ are missing, leading to confusion in the integration center and causing a variety of symptoms similar to those of car-sickness or sea-sickness. After exposure to microgravity an immediate process of re-programming will begin and be completed in 2-4 days. There is strong supporting evidence for this sensory conflict theory as an explanation for space motion sickness (SMS) episodes. Fish were selected as test organisms for this investigation because they swim around freely in three dimensions and have well-developed organs for vision and gravity detection. They also have an innate nature to orient their back toward a light source. Actually, on the ground, the fish tilts its vertical axis toward the light when illuminated laterally, and the tilt angle is a function of the intensity of light and the magnitude of gravity, while its posture is completely light-dependent in the low-gravity environment produced by aircraft parabolic flight or when the otolith organs are removed. This implies that fish posture is entirely under visual and otolithic control. In this case, the cerebellum will also contribute to the control. In the space shuttle experiment, two fish (one with otolith-removed and the other with intact otoliths) are onboard for 7 days. The arrangement of the experiment is shown. Lamps illuminate each fish alternately from different directions at a duration of 20 seconds for 10 minutes totally, twice a day. The video images and the brain waves from the cerebellum are analyzed later. If the sensory conflict theory is acceptable, then the confusion at the onset and the following recovery process will be manifested both in the light-dependent behavior and also in the cerebellar activity. In addition, there should be some variation in response between the two fish. Even if the results are positive in the present fish experiment, they would not be extensive enough to allow us to understand the complete mechanisms of SMS. However, what is currently needed is a collection of evidence based on animal experiments on which to base future investigations. Countermeasures for SMS are mandatory since SMS-induced vomiting occurring within a space suit could be fatal for a crew member during extravehicular activities. We expect that countermeasures will be developed before the space station era starts, and that the results of these studies will be applied to improving human welfare.

Mori, Shigeo↗

SU-E-T-620: Planning and Dosimetry for Pulsed Low Dose Rate RT for Recurrent Lung, Spine, GYN and Head and Neck Cancers

Purpose: Extensive in vitro and in vivo studies have shown that pulsed low dose rate (PLDR) radiotherapy has potential to provide significant local tumor control and to reduce normal tissue toxicities. This work investigated the planning and dosimetry of PLDR re-irradiation for recurrent cancers. Methods: We analyzed the treatment plans and dosimetry for 13 recurrent patients who were treated with the PLDR technique in this study. All cases were planned with the 3DCRT technique with optimal beam angle selection. The treatment was performed on a Siemens accelerator using 6MV beams. The target volume ranged between 161 and 703cc. The previous RT dose was 40–60Gy while the re-irradiation dose was 16–60Gy. The interval between previous RT and re-irradiation was 13–336 months, and the follow-up time was up to 27months. The total prescription dose was administered in 2Gy/day fractions with the daily dose delivered in 10 sub-fractions (pulses) of 20cGy with a 3min interval between the pulses to achieve an effective dose rate of 6.7cGy/min. Results: The clinical outcome was analyzed based on the treatment plans. All pulses were kept with Dmax<40cGy. The PLDR treatments were effective (CR: 3 patients, PR: 10 patients). The acute and late toxicities were all acceptable (generally grade II or under). Two patients died three months after the PLDR re-irradiation, one due to massive cerebral infarction and the other due to acute cardiac failure. All others survived more than 8 months. Five patients showed good conditions at the last follow-up. Among them two recurrent lung cancer patients had survived 23 months and one nasopharyngeal cancer patient had survived 27 months. Conclusion: The PLDR technique was effective for the palliative treatment of head and neck, lung, spine and GYN cancers. Further phase II and III studies are warranted to quantify the efficacy of PLDR for recurrent cancers.

61 RADIATION PROTECTION AND DOSIMETRY↗

Landscape of Cross-Laminated Timber in the United States

Mass timber construction is an emerging sustainable construction practice in the United States given its renewable nature and its ability to store carbon during its use. Cross-laminated timber (CLT) is a type of mass timber construction that involves a wood panel system that is manufactured by gluing alternating lumber board layers at right angles. CLT panels have high strength, dimensional stability, and the ability to resist high compressive forces. They are considered a sustainable alternative to reinforced concrete construction because of the renewable nature of the primary wood material in CLT panels. Despite its environmental and structural benefits, the adoption rate of CLT remains low. This report investigates the current landscape of CLT use in buildings, providing information on the types of building that use CLT, how those buildings are used, and in what U.S. regions CLT is manufactured and used. This information helps identify potential barriers to adoption to inform ways to reduce these barriers. This review synthesizes insights from recent studies to offer a detailed perspective on the state of CLT adoption, its barriers, and the evolving landscape of opportunities that may facilitate its broader acceptance and use.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

SU-F-T-556: A Potential Real Time AQA for Cyberknife Cones and MLC Based Treatments

Purpose: To investigate the potential use of the Raven™ (LAP of America Laser Applications) for real time AQA of Cyberknife™ with InCise2 MLC (Accuray™ Medical). Methods: At setup, the Raven was rotated 45° on which an Accuray™ AQA cube was positioned. Three different AQA plans for fixed cone, InCise2MLC, and a modified MLC plan were delivered repeatedly ten times. The additional shapes in modified AQA plan enable additional reproducibility checks for all the MLC pairs. During the test, the cube was aligned by imbedded fiducials and irradiated. The two angled radiation beams aimed center tungsten ball of the cube and projected 45° to phosphor screen and registered by a CCD camera of the Raven device. The centricity of the metal ball in the irradiated field was then analyzed using Matlab codes. Results: For AP images, the average offsets of X, Y, and radial directions are 0.24 ± 0.04 mm, 0.25 ± 0.02 mm and 0.35 ±± 0.03 mm respectively for the cone; 0.34 ± 0.02 mm, 0.49 ± 0.04 mm and 0.60 ± 0.04 mm respectively for the MLC. For lateral images, they are 0.63 ± 0.05 mm, 0.11 ± 0.02 mm and 0.64 ± 0.04 mm respectively for the cone, 0.79 ± 0.08 mm, −0.23 ± 0.06 mm and 0.82 ± 0.09 mm respectively for the MLC. No inconsistent MLC shapes were found in the modified AQA group. Conclusion: The results are consistent with clinically acceptable values (≤1mm from baseline). The results suggest the potential of replacement of the standard AQA test with the novel real-time Raven device for Cyberknife daily QA. The modified MLC based AQA provides a more comprehensive MLC daily QA capability. Further improvements in its resolution and automatic analyzing capability are warranted.

60 APPLIED LIFE SCIENCES↗

The inter- and intrafraction reproducibilities of three common IMRT delivery techniques

Purpose: Intensity modulated radiation therapy (IMRT) treatment delivery requires higher precision than conventional 3D treatment delivery because of the sensitivity of the resulting dose to small geometric misalignment of the modulated beamlets. The chosen treatment delivery technique will affect the treatment precision in different ways, based on the characteristics of the delivery method. Delivery using a multileaf collimator (MLC) can reduce treatment time and therapist workload, but typically requires a greater number of monitor units and the fields are prone to both systematic and random leaf positioning errors. An alternative to MLC-based fields, patient specific brass compensators, do not suffer from these leaf positioning errors. In our study, we set out to investigate which delivery method will provide the highest levels of dosimetric reproducibility and the minimum amount of interfraction variability. Methods: In our study, a seven field IMRT plan for a head and neck treatment was created using the Pinnacle{sup 3} treatment planning system and the intensity maps for each field were obtained. The intensity maps of the fields were delivered with a Varian 2100C/D linear accelerator, using solid compensators and sliding window (SW) and step-and-shoot (SS) MLC segments. Three fields were selected from the seven-beam IMRT plan for comparison. Analysis was carried out using the MatriXX ion chamber array, radiochromic film, and Varian dynalog files. Results: Our results show that the error in MLC leaf positioning has no gantry angle dependence. The compensator and SW deliveries showed excellent agreement, even when stricter than usual gamma criteria were applied. However, we noted that under these strict conditions, the SS fields had at least ten times more pixels out of range than did the compensators. When using step-and-shoot MLC fields, it was observed that the increase in dose rate or the increase of MU/segment degrades the quality of the plan. Analysis of the dynalog files showed that while each individual field had its own propensity for error, all fields showed the same trend: a greater percentage of time the leaves are out of position as dose rate increases, MUs decrease, or both. Conclusions: The compensator-based field and both types of MLC-based fields have MatriXX results that are within the clinically acceptable tolerance of 3% dose difference and 2 mm DTA. However, when the criteria are tightened, it becomes evident that the compensators have a definite advantage over their comparable MLC-based competitors in terms of interfraction reproducibility. Fewer monitor units are required to deliver each portal, potentially improving patient outcomes and reducing unwanted side effects to both patients and therapists. In centers without MLC, compensators represent a simple and cost effective way to offer patients state of the art treatment. Based on the results of this study, compensator-based IMRT is a reliable, viable option for use in clinics both with and without MLC-equipped linacs.

61 RADIATION PROTECTION AND DOSIMETRY↗