Search NASA⌕ Search

SEARCH · Search NASA

Results for “active source”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 721 records · Page 40

Reconstructing the Position and Intensity of Multiple Gamma-Ray Point Sources with a Sparse Parametric Algorithm

IEEE We present an experimental demonstration of Additive Point Source Localization (APSL), a sparse parametric imaging algorithm that reconstructs the 3D positions and activities of multiple gamma-ray point sources. Using a handheld gamma-ray detector array and up to four 8 μCi 137 Cs gamma-ray sources, we performed both source-search and source-separation experiments in an indoor laboratory environment. In the majority of the source-search measurements, APSL reconstructed the correct number of sources with position accuracies of ~20 cm and activity accuracies (unsigned) of ~20%, given measurement times of two to three minutes and distances of closest approach (to any source) of ~20 cm. In source-separation measurements where the detector could be moved freely about the environment, APSL was able to resolve two sources separated by 75 cm or more given only ~60 s of measurement time. In these source-separation measurements, APSL produced larger total activity errors of ~40%, but obtained source separation distances accurate to within 15 cm. We also compare our APSL results against traditional Maximum Likelihood-Expectation Maximization (ML-EM) reconstructions, and demonstrate improved image accuracy and interpretability using APSL over ML-EM. These results indicate that APSL is capable of accurately reconstructing gamma-ray source positions and activities using measurements from existing detector hardware.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Design and Testing of a Novel Wide Range - Segmented Gamma Scanner Incorporating Tomographic Gamma Scanning for Measuring Both Low and Intermediate Level Waste in Drums - 13470

This paper describes the design and testing of a novel automated Wide Range Segmented Gamma ray Scanning (WR-SGS) assay instrument that also incorporates Tomographic Gamma Scanning (TGS). The instrument is designed for the measurement of both Low and Intermediate Level Waste (LLW and ILW) in 200 litre drums and other waste containers covering a wide range of density. Like earlier ANTECH WR-SGS instruments, the system employs a single shielded and collimated high purity germanium (HPGe) detector to quantify the radionuclide content of the waste and like conventional SGS instruments it is suitable for the measurement of relatively homogeneous waste matrices. Also, like earlier WR-SGS systems the instrument incorporates an automated variable aperture collimator, which allows the vertical segment height to be adjusted in order to measure both high dose-rate and very low activity drums. The instrument employs both conventional discrete SGS vertical segment measurements as well as vertical segment measurement by continuous helical-scanning of the drum as it rotates. This latter method reduces measurement times for SGS measurements. In order to determine the density corrections for both low and high-density drums, a high activity Eu-152 transmission source is employed. When not in use, and in place of a conventional shutter mechanism, the shielded transmission source is moved to a shielded storage position to eliminate background radiation from the source. Due to its novel features, the WR-SGS is applicable to the measurement of both very low and very high activity waste drums as well as waste drums with a wide range of density. If located in a low background position and with the effective shielding of the strong transmission source, the instrument can be used to measure very low level or exempt waste. In order to extend the range of applicability to the measurement of heterogeneous drums, TGS measurement capability has been included in the basic WR-SGS design. This is achieved by adding horizontal motion to the waste drum rotation platform and incorporating TGS collimation into the variable aperture collimator, as well as a filter to reduce the detector signal when straight-through measurements are made using the strong transmission source. Test measurements are presented of the system operating in both SGS and TGS modes using different drum densities and source strengths. The test measurement results are compared with benchmarked MCNP Monte Carlo calculations. The Wide Range SGS - TGS instrument extends the range of both activity and density that can be measured in 200 and 340 litre drums. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

The value of adding black carbon to community monitoring of particulate matter

Low-cost particulate matter (PM) sensors are increasingly used by researchers, public health agencies, and the public to measure spatial and temporal variations in air pollution, which can inform strategies for community air pollution reduction. While low-cost PM sensors provide a valuable measure of harmful fine particulate matter (PM 2.5 ), a significant portion of ambient PM 2.5 is typically the secondary product of air pollution emitted by varied sources outside of community boundaries. In contrast, concentrations of black carbon (BC), a component of PM 2.5 , are directly emitted by a few specific sources, such as diesel engines within communities. Motivated by community organizations seeking to understand persistent sources of local pollution, this study deployed a suite of custom-built BC sensors alongside a network of low-cost PM sensors for four weeks in two seasons at 50 stationary locations in the adjacent cities of Richmond, North Richmond, and San Pablo, California, east of the San Francisco Bay. Concentrations of BC varied more than PM 2.5 both temporally and spatially. Monthly network-average BC was 3×higher in winter than late spring, while PM 2.5 was only 10% lower. In both seasons, average PM 2.5 concentrations at two-thirds of sites were within ±10% of the network average, whereas two-thirds of sites had BC levels outside of ±10% of the network-average concentration. The most and least polluted locations were more persistent across seasons for BC than PM 2.5 , and the temporal dynamics of BC at these sites were similar, signifying that they are impacted by the same emission sources. Together, these spatiotemporal trends show that BC is a better indicator of the proximity and activity of local pollution sources than PM 2.5 . Thus, including BC in addition to PM 2.5 in community monitoring networks can provide additional insights about local sources of air pollution.

54 ENVIRONMENTAL SCIENCES↗

Analysis of an Actively Cooled Window for High Power Helicon Plasma Source

The development of the next generation of magnetically confined fusion facilities towards commercial fusion power will depend on an increased understanding of plasma material interactions (PMI). Plasma facing components in future facilities such as a Fusion Nuclear Science Facility (FSNF) or DEMO will experience high heat fluxes, high energy neutron fluence, and helium and hydrogen isotope permeation. This combination of environmental effects is unique to the fusion environment, and research and development in the field of PMI will require integrated facilities that can provide prototypical conditions. Particularly, facilities are required that will simulate conditions in the first wall and divertor regions. One such proposed facility is Materials Plasma Exposure experiment (MPEX). (authors)

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Measurement of Passive Uptake Rates for Volatile Organic Compounds on Commercial Thermal Desorption Tubes and the Effect of Ozone on Sampling

Diffusive or passive sampling methods using commercially filled axial-sampling thermal desorption tubes are widely used for measuring volatile organic compounds (VOCs) in air. The passive sampling method provides a robust, cost effective way to measure air quality with time-averaged concentrations spanning up to a week or more. Sampling rates for VOCs can be calculated using tube geometry and Fick’s Law for ideal diffusion behavior or measured experimentally. There is evidence that uptake rates deviate from ideal and may not be constant over time. Therefore, experimentally measured sampling rates are preferred. In this project, a calibration chamber with a continuous stirred tank reactor design and constant VOC source was combined with active sampling to generate a controlled dynamic calibration environment for passive samplers. The chamber air was augmented with a continuous source of 45 VOCs ranging from pentane to diethyl phthalate representing a variety of chemical classes and physiochemical properties. Both passive and active samples were collected on commercially filled Tenax TA thermal desorption tubes over an 11-day period and used to calculate passive sampling rates. A second experiment was designed to determine the impact of ozone on passive sampling by using the calibration chamber to passively load five terpenes on a set of Tenax tubes and then exposing the tubes to different ozone environments with and without ozone scrubbers attached to the tube inlet. During the sampling rate experiment, the measured diffusive uptake was constant for up to seven days for most of the VOCs tested but deviated from linearity for some of the more volatile compounds between seven and eleven days. In the ozone experiment, both exposed and unexposed tubes showed a similar decline in terpene mass over time indicating back diffusion when uncapped tubes were transferred to a clean environment but there was no indication of significant loss by ozone reaction.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Self-absorption Effects on Alpha-Induced Atmospheric Nitrogen Fluorescence Yield

Nitrogen fluorescence induced by alpha, beta and gamma radiation can be used to detect the presence of radioactive contamination in the environment. Successful measurement of fluorescence yield involves a number of factors, including: known fluorescence signal rate during the measurement; the effective alpha spectrum of the radioactive sources used in the measurement; optical attenuation length of the fluorescence signal in air during the measurement; the absolute throughput of the instrumentation; calibration of the instrumentation; and radiation transport modeling of the "effective" array exposure rate given the spectrum of the alpha particles. Field testing of optical instrumentation was conducted to measure the nitrogen fluorescence yield from the alpha radiation generated from americium-241 (241Am) decay. The 241Am test sources were prepared by direct evaporation of ~1 mCi in nitric acid solution, and some solids were visible on the surface of the sources. A laboratory study was conducted with lower activities of 241Am to determine whether the presence of solids on the surface of the sources prepared both by direct evaporation and by electrodeposition onto stainless steel disks produced sufficient self-absorption to cause a decrease in expected fluorescence. Alpha spectroscopy was used to determine the apparent activity of the sources versus the known activity deposited on the surface. Results from the self-absorption laboratory studies were used to correct the activity values in the model and calculate the nitrogen fluorescence generated by the 241Am during the field experiments.

36 MATERIALS SCIENCE↗

The evolving activity of the dynamically young comet C/2009 P1 (Garradd)

We used the Ultraviolet-Optical Telescope on board Swift to observe the dynamically young comet C/2009 P1 (Garradd) from a heliocentric distance of 3.5 AU pre-perihelion until 4.0 AU outbound. At 3.5 AU pre-perihelion, comet Garradd had one of the highest dust-to-gas ratios ever observed, matched only by comet Hale-Bopp. The evolving morphology of the dust in its coma suggests an outburst that ended around 2.2 AU pre-perihelion. Comparing slit-based measurements and observations acquired with larger fields of view indicated that between 3 AU and 2 AU pre-perihelion a significant extended source started producing water in the coma. We demonstrate that this source, which could be due to icy grains, disappeared quickly around perihelion. Water production by the nucleus may be attributed to a constantly active source of at least 75 km{sup 2}, estimated to be >20% of the surface. Based on our measurements, the comet lost 4 × 10{sup 11} kg of ice and dust during this apparition, corresponding to at most a few meters of its surface. Even though this was likely not the comet's first passage through the inner solar system, the activity of Garradd was complex and changed significantly during the time it was observed.

79 ASTRONOMY AND ASTROPHYSICS↗

The Second Catalog of Flaring Gamma-Ray Sources from theFermi All-sky Variability Analysis

We present the second catalog of flaring gamma-ray sources (2FAV) detected with the Fermi All-sky Variability Analysis (FAVA), a tool that blindly searches for transients over the entire sky observed by the Large Area Telescope (LAT) on board the Fermi Gamma-ray Space Telescope. With respect to the first FAVA catalog, this catalog benefits from a larger data set, the latest LAT data release (Pass 8), as well as from an improved analysis that includes likelihood techniques for a more precise localization of the transients. Applying this analysis to the first 7.4 years of Fermi observations, and in two separate energy bands 0.1–0.8 GeV and 0.8–300 GeV, a total of 4547 flares were detected with significance greater than 6σ (before trials), on the timescale of one week. Through spatial clustering of these flares, 518 variable gamma-ray sources were identified. Based on positional coincidence, likely counterparts have been found for 441 sources, mostly among the blazar class of active galactic nuclei. For 77 2FAV sources, no likely gamma-ray counterpart has been found. For each source in the catalog, we provide the time, location, and spectrum of each flaring episode. Studying the spectra of the flares, we observe a harder-when-brighter behavior for flares associated with blazars, with the exception of BL Lac flares detected in the low-energy band. The photon indexes of the flares are never significantly smaller than 1.5. For a leptonic model, and under the assumption of isotropy, this limit suggests that the spectrum of freshly accelerated electrons is never harder than p∼2.

79 ASTRONOMY AND ASTROPHYSICS↗

NuSTAR AND CHANDRA INSIGHT INTO THE NATURE OF THE 3-40 keV NUCLEAR EMISSION IN NGC 253

We present results from three nearly simultaneous Nuclear Spectroscopic Telescope Array (NuSTAR) and Chandra monitoring observations between 2012 September 2 and 2012 November 16 of the local star-forming galaxy NGC 253. The 3-40 keV intensity of the inner {approx}20 arcsec ({approx}400 pc) nuclear region, as measured by NuSTAR, varied by a factor of {approx}2 across the three monitoring observations. The Chandra data reveal that the nuclear region contains three bright X-ray sources, including a luminous (L{sub 2-10{sub keV}} {approx} few Multiplication-Sign 10{sup 39} erg s{sup -1}) point source located {approx}1 arcsec from the dynamical center of the galaxy (within the 3{sigma} positional uncertainty of the dynamical center); this source drives the overall variability of the nuclear region at energies {approx}>3 keV. We make use of the variability to measure the spectra of this single hard X-ray source when it was in bright states. The spectra are well described by an absorbed (N{sub H} Almost-Equal-To 1.6 Multiplication-Sign 10{sup 23} cm{sup -2}) broken power-law model with spectral slopes and break energies that are typical of ultraluminous X-ray sources (ULXs), but not active galactic nuclei (AGNs). A previous Chandra observation in 2003 showed a hard X-ray point source of similar luminosity to the 2012 source that was also near the dynamical center ({theta} Almost-Equal-To 0.4 arcsec); however, this source was offset from the 2012 source position by Almost-Equal-To 1 arcsec. We show that the probability of the 2003 and 2012 hard X-ray sources being unrelated is >>99.99% based on the Chandra spatial localizations. Interestingly, the Chandra spectrum of the 2003 source (3-8 keV) is shallower in slope than that of the 2012 hard X-ray source. Its proximity to the dynamical center and harder Chandra spectrum indicate that the 2003 source is a better AGN candidate than any of the sources detected in our 2012 campaign; however, we were unable to rule out a ULX nature for this source. Future NuSTAR and Chandra monitoring would be well equipped to break the degeneracy between the AGN and ULX nature of the 2003 source, if again caught in a high state.

79 ASTRONOMY AND ASTROPHYSICS↗

Measuring and Modeling Naturally Occurring Radioactive Material: Interpreting the Relationship Between the Natural Radionuclides Present

The regulatory release of sites and facilities (property) for restricted or unrestricted use has evolved beyond prescribed levels to model-derived dose and risk based limits. Dose models for deriving corresponding soil and structure radionuclide concentration guidelines are necessarily simplified representations of complex processes. A conceptual site model is often developed to present a reasonable and somewhat conservative representation of the physical and chemical properties of the impacted material. Dose modeling software is then used to estimate resulting dose and/or radionuclide specific acceptance criteria (activity concentrations). When the source term includes any or all of the uranium, thorium or actinium natural decay series radionuclides the interpretation of the relationship between the individual radionuclides of the series is critical to a technically correct and complete assessment of risk and/or derivation of radionuclide specific acceptance criteria. Unlike man-made radionuclides, modeling and measuring naturally occurring radioactive material (NORM) and technologically enhanced NORM (TENORM) source terms involves the interpretation of the relationship between the radionuclide present, e.g., secular equilibrium, enrichment, depletion or transient equilibrium. Isotopes of uranium, radium, and thorium occur in all three natural decay series. Each of the three series also produces a radon gas isotope as one of its progeny. In nature, the radionuclides in the three natural decay series are in a state that is approaching or has achieved secular equilibrium, in which the activities of all radionuclides within each series are nearly equal. However, ores containing the three natural decay series may begin in approximate secular equilibrium, but after processing, equilibrium may be broken and certain elements (and the radioactive isotopes of that element) may be concentrated or removed. Where the original ore may have contained one long chain of natural decay series radionuclides, the resulting TENORM source term may contain several smaller decay chains, each headed by a different longer lived member of the original series. This paper presents the anatomy of common TENORM source terms and the pitfalls of measuring, interpreting and modeling these source terms. Modeling TENORM with common software such as RESRAD is discussed. In summary: RESRAD modeling (dose assessments) to derive single radionuclide, dose based acceptance criteria, requires a good understanding of the physical, chemical and biological factors/input parameters applicable to the selected exposure scenario(s). When NORM or TENORM source terms are modeled, an additional understanding of the status of equilibrium, is necessary to accurately perform a dose assessment in support of dose based acceptance criteria. Historical information about the site processes/ores, selection of appropriate analytical analyses to identify key decay series radionuclide and a comprehensive review of the characterization data are needed to understand the equilibrium status of the decay series present. Once the source term has been characterized (in regards to relative activities of the radionuclides within a decay series) the source term must be input into RESRAD to reflect that status of equilibrium at time zero, or at the time since placement, if the characterization data reflects the equilibrium status of dated material. When the RESRAD output file is reviewed, depending on the time of maximum dose, DCGL values may be artificially high in value. Sum of fraction calculations, based on the status of equilibrium of each decay series, can also be used to assess the RESRAD results and develop an appropriate MARSSIM final status survey protocol. (authors)

54 ENVIRONMENTAL SCIENCES↗

Structure of the Bifunctional Acyltransferase/Decarboxylase LnmK from the Leinamycin Biosynthetic Pathway Revealing Novel Activity for a Double-Hot-Dog Fold

The β-branched C3 unit in leinamycin biosynthesis is installed by a set of four proteins, LnmFKLM. In vitro biochemical investigation confirmed that LnmK is a bifunctional acyltransferase/decarboxylase (AT/DC) that catalyzes first self-acylation using methylmalonyl-CoA as a substrate and subsequently transacylation of the methylmalonyl group to the phosphopantetheinyl group of the LnmL acyl carrier protein [Liu, T., Huang, Y., and Shen, B. (2009) J. Am. Chem. Soc. 131, 6900–6901]. LnmK shows no sequence homology to proteins of known function, representing a new family of AT/DC enzymes. Here we report the X-ray structure of LnmK. LnmK is homodimer with each of the monomers adopting a double-hot-dog fold. Cocrystallization of LnmK with methylmalonyl-CoA revealed an active site tunnel terminated by residues from the dimer interface. But, to canonical AT and ketosynthase enzymes that employ Ser or Cys as an active site residue, none of these residues are found in the vicinity of the LnmK active site. Instead, three tyrosines were identified, one of which, Tyr62, was established, by site-directed mutagenesis, to be the most likely active site residue for the AT activity of LnmK. Moreover, LnmK represents the first AT enzyme that employs a Tyr as an active site residue and the first member of the family of double-hot-dog fold enzymes that displays an AT activity known to date. The LnmK structure sets the stage for probing of the DC activity of LnmK through site-directed mutagenesis. These findings highlight natural product biosynthetic machinery as a rich source of novel enzyme activities, mechanisms, and structures.

Lohman, Jeremy R.↗

Pre-equilibrium reactions involving pendent relays improve CO 2 reduction mediated by molecular Cr-based electrocatalysts

Homogeneous earth abundant transition-metal electrocatalysts capable of carbon dioxide (CO 2 ) reduction to generate value-added chemical products are a possible strategy to minimize rising anthropogenic CO 2 emissions. Previously, it was determined that Cr-centered bipyridine-based N 2 O 2 complexes for CO 2 reduction are kinetically limited by a proton-transfer step during C–OH bond cleavage. Therefore, it was hypothesized that the inclusion of pendent relay groups in the secondary coordination sphere of these molecular catalysts could increase their catalytic activity. Here, it is shown that the introduction of a pendent methoxy group favorably impacts a pre-equilibrium protonation prior to the catalytic resting state, resulting in a significant increase in catalytic activity without a loss of product selectivity for generating carbon monoxide (CO) from CO 2 . Interestingly, combining the pendent methoxy group with a cationic acid causes a positive shift of the catalytic reduction potential of the system, while maintaining increased activity and quantitative selectivity. This work suggests that tuning the secondary coordination sphere with respect to cationic proton sources can result in activity improvements by modifying the kinetic and thermodynamic aspects of proton transfer in the catalytic cycle.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗