Search NASA⌕ Search

SEARCH · Search NASA

Results for “base effect”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 721 records · Page 40

Study of the oxidation effects on isothermal solidification based high temperature stable Pt/In/Au and Pt/In/Ag thick film interconnections on LTCC substrate

The objective of the presented paper is to determine the oxidized phase compositions of indium lead-free solders during solidification at 190 ° C under room environment with the help of X-ray diffraction (XRD) and Energy dispersive spectroscopy (EDX). Many lead-free solders alloys available oxidizes and have poor wetting properties. The oxidation of pure indium solder foil, Au, Pt, and Ag alloys were identified and investigated, in the process of isothermal solidification based solder joints construction at room environment and humidity. Both EDX and XRD characterization techniques were performed to trace out the amount of oxide levels and variety of oxide formations at solder interface respectively. The paper also aims to report the isothermal solidification technique to provide interconnections to pads on Low temperature co-fired ceramic (LTCC) substrate. It also elaborates advantages of isothermal solidification over the other methods of interconnection. Scanning electron microscope (SEM) used to identify the oxidized spots on the surface of Pt, Ag substrates and In solder. The identified oxides were reported.

36 MATERIALS SCIENCE↗

Molecular dynamics based study on the effects of cation size on the local structure and diffusion in polymerized ionic liquids

We have used coarse-grained molecular dynamics simulations to understand the effect of cation size on ion diffusion in polymerized ionic liquids at temperatures well above the glass transition temperature of the polymers. We investigated dependencies of the diffusion constant on the cation radius and static dielectric constant and interpreted these results in terms of underlying structural changes, and decoupling phenomenon. We have found non-monotonic effects of the cation radius on the diffusion constant, with a maximum at an intermediate radius resulting from two different size dependent effects. Changes in the radial distribution functions characterizing spatial distribution of cations with respect to anions result in a monotonic increase in the coordination number. This yields an increase in the effective interaction energy as a function of cation radius, which can explain the decrease in the diffusion constant. This increase is counteracted at small cation radii by a corresponding increase in decoupling of cation and anion dynamics. In addition, the diffusion constant is found to increase on increasing the static dielectric constant for all radii of the cations. These results highlight the significant role of decoupling in designing polymerized ionic liquids with an enhanced diffusion constant of cations.

Gillespie, Colin [ORNL] (ORCID:0000000320287080)↗

Complete treatment of galaxy two-point statistics: Gravitational lensing effects and redshift-space distortions

We present a coherent theoretical framework for computing gravitational lensing effects and redshift-space distortions in an inhomogeneous universe and investigate their impacts on galaxy two-point statistics. Adopting the linearized Friedmann-Lemaitre-Robertson-Walker metric, we derive the gravitational lensing and the generalized Sachs-Wolfe effects that include the weak lensing distortion, magnification, and time delay effects, and the redshift-space distortion, Sachs-Wolfe, and integrated Sachs-Wolfe effects, respectively. Based on this framework, we first compute their effects on observed source fluctuations, separating them as two physically distinct origins: the volume effect that involves the change of volume and is always present in galaxy two-point statistics, and the source effect that depends on the intrinsic properties of source populations. Then we identify several terms that are ignored in the standard method, and we compute the observed galaxy two-point statistics, an ensemble average of all the combinations of the intrinsic source fluctuations and the additional contributions from the gravitational lensing and the generalized Sachs-Wolfe effects. This unified treatment of galaxy two-point statistics clarifies the relation of the gravitational lensing and the generalized Sachs-Wolfe effects to the metric perturbations and the underlying matter fluctuations. For near-future dark energy surveys, we compute additional contributions to the observed galaxy two-point statistics and analyze their impact on the anisotropic structure. Thorough theoretical modeling of galaxy two-point statistics would be not only necessary to analyze precision measurements from upcoming dark energy surveys, but also provide further discriminatory power in understanding the underlying physical mechanisms.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Genotyping‐in‐Thousands by sequencing (GT‐seq): A cost effective SNP genotyping method based on custom amplicon sequencing

Abstract Genotyping‐in‐Thousands by sequencing ( GT ‐seq) is a method that uses next‐generation sequencing of multiplexed PCR products to generate genotypes from relatively small panels (50–500) of targeted single‐nucleotide polymorphisms ( SNP s) for thousands of individuals in a single Illumina HiSeq lane. This method uses only unlabelled oligos and PCR master mix in two thermal cycling steps for amplification of targeted SNP loci. During this process, sequencing adapters and dual barcode sequence tags are incorporated into the amplicons enabling thousands of individuals to be pooled into a single sequencing library. Post sequencing, reads from individual samples are split into individual files using their unique combination of barcode sequences. Genotyping is performed with a simple perl script which counts amplicon‐specific sequences for each allele, and allele ratios are used to determine the genotypes. We demonstrate this technique by genotyping 2068 individual steelhead trout ( Oncorhynchus mykiss ) samples with a set of 192 SNP markers in a single library sequenced in a single Illumina HiSeq lane. Genotype data were 99.9% concordant to previously collected TaqMan ™ genotypes at the same 192 loci, but call rates were slightly lower with GT ‐seq (96.4%) relative to Taqman (99.0%). Of the 192 SNP s, 187 were genotyped in ≥90% of the individual samples and only 3 SNP s were genotyped in <70% of samples. This study demonstrates amplicon sequencing with GT ‐seq greatly reduces the cost of genotyping hundreds of targeted SNP s relative to existing methods by utilizing a simple library preparation method and massive efficiency of scale.

Campbell, Nathan R.↗

Proton Irradiation Effects on Sb-based Heterojunction Bipolar Transistors

In0.52Al0.48As/In0.39Ga0.61As0.77Sb0.23/In0.53Ga0.47As double heterojunction bipolar transistors (DHBTs) were irradiated with 5 MeV protons at fluences from 2 1011 to 2 1015 protons/cm2. The radiation produced significant increases in generation-recombination leakage current in both emitter-base and base-collector junctions. The DHBTs irradiated with a dose of 2 1011 cm-2, which was equivalent to around 40 years of exposure in low earth orbit, showed minimal changes in the junction ideality factor, generation recombination leakage current, current gain and output conductance. The InAlAs/InGaAsSb/InGaAs DHBTs appear to be well-suited to space or nuclear industry applications.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Beam hardening effects in grating-based x-ray phase-contrast imaging

Purpose: In this work, the authors investigate how beam hardening affects the image formation in x-ray phase-contrast imaging and consecutively develop a correction algorithm based on the results of the analysis. Methods: The authors' approach utilizes a recently developed x-ray imaging technique using a grating interferometer capable of visualizing the differential phase shift of a wave front traversing an object. An analytical description of beam hardening is given, highlighting differences between attenuation and phase-contrast imaging. The authors present exemplary beam hardening artifacts for a number of well-defined samples in measurements at a compact laboratory setup using a polychromatic source. Results: Despite the differences in image formation, the authors show that beam hardening leads to a similar reduction of image quality in phase-contrast imaging as in conventional attenuation-contrast imaging. Additionally, the authors demonstrate that for homogeneous objects, beam hardening artifacts can be corrected by a linearization technique, applicable to all kinds of phase-contrast methods using polychromatic sources. Conclusions: The evaluated correction algorithm is shown to yield good results for a number of simple test objects and can thus be advocated in medical imaging and nondestructive testing.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Effects of CT-based attenuation correction of rat microSPECT images on relative myocardial perfusion and quantitative tracer uptake

Purpose: Our goal in this work was to investigate the impact of CT-based attenuation correction on measurements of rat myocardial perfusion with {sup 99m}Tc and {sup 201}Tl single photon emission computed tomography (SPECT). Methods: Eight male Sprague-Dawley rats were injected with {sup 99m}Tc-tetrofosmin and scanned in a small animal pinhole SPECT/CT scanner. Scans were repeated weekly over a period of 5 weeks. Eight additional rats were injected with {sup 201}Tl and also scanned following a similar protocol. The images were reconstructed with and without attenuation correction, and the relative perfusion was analyzed with the commercial cardiac analysis software. The absolute uptake of {sup 99m}Tc in the heart was also quantified with and without attenuation correction. Results: For {sup 99m}Tc imaging, relative segmental perfusion changed by up to +2.1%/−1.8% as a result of attenuation correction. Relative changes of +3.6%/−1.0% were observed for the {sup 201}Tl images. Interscan and inter-rat reproducibilities of relative segmental perfusion were 2.7% and 3.9%, respectively, for the uncorrected {sup 99m}Tc scans, and 3.6% and 4.3%, respectively, for the {sup 201}Tl scans, and were not significantly affected by attenuation correction for either tracer. Attenuation correction also significantly increased the measured absolute uptake of tetrofosmin and significantly altered the relationship between the rat weight and tracer uptake. Conclusions: Our results show that attenuation correction has a small but statistically significant impact on the relative perfusion measurements in some segments of the heart and does not adversely affect reproducibility. Attenuation correction had a small but statistically significant impact on measured absolute tracer uptake.

60 APPLIED LIFE SCIENCES↗

Electrical properties of the InP/InGaAs pnp heterostructure-emitter bipolar transistor

The dc performances of an InP/InGaAs pnp heterostructure-emitter bipolar transistor are investigated by theoretical analysis and experimental results. Though the valence band discontinuity at the InP/InGaAs heterojunction is relatively large, the addition of a heavily-doped as well as thin p{sup +}-InGaAs emitter layer between p-InP confinement and n{sup +}-InGaAs base layers effectively eliminates the potential spike at emitter-base junction and simultaneously lowers the emitter-collector offset voltage and increases the potential barrier for electrons. Experimentally, a high current gain of 88 and a low offset voltage of 54 mV have been achieved.

36 MATERIALS SCIENCE↗

Incident excitation effects on ZnO-based photoluminescence

Zinc oxide (ZnO) is an attractive semiconductor material owing to a wide band gap, large exciton binding energy, and strong luminescent properties. Two distinct spectral regions are present in the room temperature emission of this material: a narrow line in the UV/near-UV region that is excitonic in nature and a lower energy broad emission band centered in the green/yellow region. Commercially available ZnO particles containing excess Zn and oxygen vacancy defect sites (referred to as ZnO:Zn) were excited using three light sources to study different radiative recombination regimes of the as-received powders. First, a UV LED at a center wavelength of 365 nm provided low irradiance (0.02–0.08 W/cm 2 ) with varying pulse widths (continuous operation to 16 ns). Second, the third harmonic of a pulsed Nd:YAG laser provided high irradiances (∼10 4 –10 6 W/cm 2 ) at a fixed nominal pulse width of 5 ns. Finally, a continuous polychromatic synchrotron X-ray source was also used to excite the ZnO:Zn powders. During UV LED excitation, a low number of carriers are created in the material, leading to an anticipated linear relationship between luminescence and irradiance. This held true for defect luminescence; however, there was an observed enhancement of exciton emission relative to the UV LED intensity as the pulse width was decreased, independent of irradiance. During UV laser excitation, the number of carriers was significantly increased, raising the material into a bimolecular recombination regime, which produced exciton emission much stronger than visible band emission. Finally, spectra obtained during synchrotron X-ray excitation, whose continuous illumination and higher penetration depth yielded higher emission from defect sites relative to exciton emission. A redshift in the exciton emission was also observed as excitation pulse width and sample temperature were varied, and is discussed.

Westphal, Eric Robert [Sandia National Lab. (SNL-N↗

Reading Between the Lines: Measuring the Effects of Linguistic-Based Indicators of Deception on Experts’ Identification and Categorization of Disinformation

There is currently very limited research into how experts analyze and assess potentially fraudulent content in their expertise areas, and most research within the disinformation space involves very limited text samples (e.g., news headlines). The overarching goal of the present study was to explore how an individual’s psychological profile and the linguistic features in text might influence an expert’s ability to discern disinformation/fraudulent content in academic journal articles. At a high level, the current design tasked experts with reading journal articles from their area of expertise and indicating if they thought an article was deceptive or not. Half the articles they read were journal papers that had been retracted due to academic fraud. Demographic and psychological inventory data collected on the participants was combined with performance data to generate insights about individual expert susceptibility to deception. Our data show that our population of experts were unable to reliably detect deception in formal technical writing. Several psychological dimensions such as comfort with uncertainty and intellectual humility may provide some protection against deception. This work informs our understanding of expert susceptibility to potentially fraudulent content within official, technical information and can be used to inform future mitigative efforts and provide a building block for future disinformation work.

99 GENERAL AND MISCELLANEOUS↗