Search NASA⌕ Search

SEARCH · Search NASA

Results for “calibration source”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 721 records · Page 40

Intercomparison of neutral composition measurements from the satellite Esro 4, Aeros A, Aeros B, and Atmosphere Explorer C

Number-density data obtained at orbital 'crossover' points with the neutral-gas mass spectrometers aboard the Esro 4, Aeros A, AE-C, and Aeros B satellites are intercompared. All the mass spectrometers were designed to measure the ambient number densities of atomic oxygen, molecular nitrogen, helium, and argon. It is found that the agreement for N2 and O is satisfactory within the experimental errors and that the He measurements exhibit unexpectedly large discrepancies far outside the error range. Calibration and instrument sources of error are considered.

Trinks, H.↗

Ray-tracing the convex curved crystal X-ray spectrograph

The convex curved crystal X-ray spectrograph has recently seen increasing use for the spectral analysis of transient plasmas. The present paper describes the calculation of ray paths through the spectrograph for both localized and extended sources. The method traces a ray from any given source point to its point of diffraction by the curved crystal and then to the imaging circle, where the image point is obtained. Application of the ray tracing method is made to some actual experimental configurations to obtain resolution values and source sizes. Wavelength calibrations are obtainable with the ray tracing method in advance of instrument construction.

Kastner, S. O.↗

Particle excitation, airglow and H2 vibrational disequilibrium in the atmosphere of Jupiter

The extreme ultraviolet EUV emission produced by particle excitation of the hydrogen atmospheres of Jupiter and Saturn is examined using model calculations to determine the nature of the energy deposition process and the effect of such processes on atmospheric structure. Tasks ranging from examination of phenomenologically related processes on Saturn and Titan to analysis of experimental laboratory data required to allow accurate modeling of emissions from hydrogenic atmospheres are investigated. An explanation of the hydrogen H Ly(alpha) bulge in Jupiter's emission from the equatorial region is presented. It is proposed that Saturn, rather then Titan is the major source of the extended hydrogen cloud. The atomic hydrogen detected at the rings of Saturn may originate predominantly from the same source. A cross calibration is obtained between the Pioneer 10 EUV photometer and the Voyager EUV spectrometers, thus providing a direct measure of the temporal morphology of Jupiter between a minimum and a maximum in solar activity. Atomic and molecular data required for the research program are analyzed. An extrapolation of conditions in the upper atmospheres of Jupiter and Saturn produces a predicted condition at Uranus in terms of excitation and hydrogen escape rates that may be observed at Voyager-Uranus encounter.

Shemansky, D. E.↗

LANDSAT 4 band 6 data evaluation

Comparison of underflight data with satellite estimates of temperature revealed significant gain calibration errors. The source of the LANDSAT 5 band 6 error and its reproducibility is not yet adequately defined. The error can be accounted for using underflight or ground truth data. When underflight data are used to correct the satellite data, the residual error for the scene studied was 1.3K when the predicted temperatures were compared to measured surface temperature.

Source record↗

Mobile VLBI and GPS measurement of vertical crustal motion

Mobile Very Long Base Interferometry (VLBI) and Global Positioning System (GPS) geodetic measurements have many error sources in common. Calibration of the effects of water vapor on signal transmission through the atmosphere, however, remains the primary limitation to the accuracy of vertical crustal motion measurements made by either technique. The two primary methods of water vapor calibration currently in use for mobile VLBI baseline measurements were evaluated: radiometric measurements of the sky brightness near the 22 GHz emission line of free water molecules and surface meteorological measurements used as input to an atmospheric model. Based upon a limited set of 9 baselines, it is shown that calibrating VLBI data with water vapor radiometer measurements provides a significantly better fit to the theoretical decay model than calibrating the same data with surface meteorological measurements. The effect of estimating a systematic error in the surface meteorological calibration is shown to improve the consistency of the vertical baseline components obtained by the two calibration methods. A detailed error model for the vertical baseline components obtained indicates current mobile VLBI technology should allow accuracies of order 3 cm with WVR calibration and 10 cm when surface meteorological calibration is used.

Kroger, P. M.↗

Cryogenic Shutter

Electrically actuated shutter designed to operate many thousands of time at cryogenic temperatures. Open shutter allows light at wavelenghts between 1 and 300 micrometers to enter instrument measures background cosmic radiation. Closed shutter blocks outside radiation from instrument and positions mirror to reflect light from internal source to instrument calibrated. Designed, if power failure occurs, shutter remains in or assumes open position so measurements continue without calibration.

Tyler, Allen↗

Automated calibration of a flight particle spectrometer

An automatic calibration system was designed for use in the vacuum facility at the Space Science Laboratory of the Marshall Space Flight Center. That system was developed and used in the intervening winter to calibrate the ion spectrometer that eventually flew in May 1986 aboard the NASA project, CRIT 1. During this summer, it is planned to implement the calibration of both an ion and electron spectrometer of a new design whose basic elements were conceived during the winter of 1985 to 1986. This spectrometer was completed in the summer and successfully mounted in the vacuum tank for calibration. However, the source gate valve malfunctioned, and, at the end of the summer, it still needed a replacement. During the inevitable delays in the experimental research, the numerical model of the Critical Velocity effect was completed and these results were presented.

Torbert, Roy B.↗

Mobile very long baseline interferometry and Global Positioning System measurement of vertical crustal motion

Mobile Very Long Base Interferometry (VLBI) and Global Positioning System (GPS) geodetic measurements have many error sources in common. Calibration of the effects of water vapor on signal transmission through the atmosphere, however, remains the primary limitation to the accuracy of vertical crustal motion measurements made by either technique. The two primary methods of water vapor calibration currently in use for mobile VLBI baseline measurements were evaluated: radiometric measurements of the sky brightness near the 22 GHz emission line of free water molecules and surface meteorological measurements used as input to an atmospheric model. Based upon a limited set of 9 baselines, it is shown that calibrating VLBI data with water vapor radiometer measurements provides a significantly better fit to the theoretical decay model than calibrating the same data with surface meteorological measurements. The effect of estimating a systematic error in the surface meteorological calibration is shown to improve the consistency of the vertical baseline components obtained by the two calibration methods. A detailed error model for the vertical baseline components obtained indicates current mobile VLBI technology should allow accuracies of order 3 cm with WVR calibration and 10 cm when surface meteorological calibration is used.

Kroger, Peter M.↗

XUV radiometric standards at NBS

The far-UV and XUV detector calibration services at NBS, the properties of the detectors, and the spectrometer calibration facilities at the Synchrotron Ultraviolet Radiation Facility (SURF II) at NBS are described. The method used to calibrate the quantum efficiency of windowless photodiode detectors in the ionization chamber, and the facilities for calibrating photodiodes at various wavelengths are discussed. The cathode and anode of the windowless photodiodes and their operation are examined. Consideration is given to the calculation of spectral irradiance from SURF II; the two stations of the spectrometer facility; the large spectrometer calibration chamber; and sources of error in flux determinations for SURF II.

Ott, W. R.↗

Strong north/south asymmetry in the Jovian stratosphere

Trailed spectra of standard B stars have been used as the 'flat' field light source for spatial calibration of IUE large-aperture observations of the north and south polar regions of Jupiter. Longward of 2000 A, the south polar spectrum is lower than the north polar one by a factor of 2.5; shortward of 2000 A, strong C2H2 absorption appears in both north polar and midlatitude spectra, while neither continuum nor band absorption features of C2H2 appear in the south polar spectrum. The very low reflectivity of the south polar region calls for the presence of a stratospheric absorber at pressures lower than 10 mbar.

Wagener, Richard↗

Optical design for the ATLAS multispectral scanner

The Airborne Terrestrial Applications Sensor (ATLAS) system is a 15-channel imager for remote sensing applications currently under development at the NASA Stennis Space Center. This paper describes the optical design of the scan head optics, which include the linescan mirror, Dall-Kirkham telescope, collimator, and three spectrometers. The sensor package has a 7.5-inch entrance aperture with a 2.0 mrad ifov, total field of view of 73 degrees, and scan rates adjustable in the range 6-50 rev/sec. The three spectrometers have a modular design for future applications growth. Design and specifications for the telescope, special dichroics, gratings, imaging lenses, and other components for the spectrometers are described. Detector arrays for the three spectrometers, and built-in sources for radiometric calibration, will also be discussed. Finally, results of overall ATLAS systems performance analysis on optical throughput, SNR and NETD are presented.

Damommio, T.↗

TIMED Doppler Interferometer

The Timed Doppler Interferometer (TIDI) will accurately and precisely determine the global vector MLTI (Mesosphere and Lower Thermosphere) wind, temperature, and density profiles. It will measure characteristics of the gravity wave and planetary wave spectra. The tidal characteristics of temperature, density, and wind in the MLTI will be determined. The neutral and ion winds will be measured to characterize the electrodynamical behavior of the MLTI. Oxygen and O2 abundances and nocticulent cloud activity will be measured. This review goes into the calibration and error sources, optical design, mechanisms design, detector design, electronics design, microprocessor and flight software design, and quality assurance and parts.

Killeen, Timothy L.↗

SeaWiFS Technical Report Series: SeaWiFS Calibration Topics - Volume 39

For Earth-observing satellite instruments, it was standard to consider each instrument band to have a spectral response that is infinitely narrow, i.e., to have a response from a single wavelength. The Sea-viewing Wide Field-of-view Sensor (SeaWiFS) bands, however, have nominal spectral bandwidths of 20 and 40nm. These bandwidths affect the SeaWiFS measurements on orbit. The effects are also linked to the manner in which the instrument was calibrated and to the spectral shape of the radiance that SeaWiFS views. Currently, SeaWiFS is calibrated such that the digital counts from each instrument band are linked to the Earth-exiting radiance at an individual center wavelength. Before launch, SeaWiFS will be recalibrated so that the digital counts from each band will be linked to the Earth-exiting radiance integrated over the spectral response of that band. In this technical memorandum, the effects of the instrument calibration and the source spectral shape on SeaWiFS measurements, including the in-band and out-of-band responses, and the center wavelengths are discussed.

Hooker, Stanford B.↗

WIND MEASUREMENTS WITH HIGH-ENERGY DOPPLER LIDAR

Coherent lidars at 2-micron wavelengths from holmium or thulium solid-state lasers have been in use to measure wind for applications in meteorology, aircraft wake vortex tracking, and turbulence detection [1,2,3] These field-deployed lidars, however, have generally been of a pulse energy of a few millijoules, limiting their range capability or restricting operation to regions of high aerosol concentration such as the atmospheric boundary layer. Technology improvements in the form of high-energy pulsed lasers, low noise detectors, and high optical quality telescopes are being evaluated to make wind measurements to long ranges or low aerosol concentrations. This research is aimed at developing lidar technology for satellite-based observation of wind on a global scale. The VALIDAR project was initiated to demonstrate a high pulse energy coherent Doppler lidar. VALIDAR gets its name from the concept of validation lidar, in that it can serve as a calibration and validation source for future airborne and spaceborne lidar missions. VALIDAR is housed within a mobile trailer for field measurements.

Koch, Grady J.↗

Antennas for the array-based Deep Space Network: current status and future designs

Development of very large arrays1,2 of small antennas has been proposed as a way to increase the downlink capability of the NASA Deep Space Network DSN) by two or three orders of magnitude thereby enabling greatly increased science data from currently configured missions or enabling new mission concepts. The current concept is for an array of 400 x 12-m antennas at each of three longitudes. The DSN array will utilize radio astronomy sources for phase calibration and will have wide bandwidth correlation processing for this purpose. NASA has undertaken a technology program to prove the performance and cost of a very large DSN array. Central to that program is a 3-element interferometer to be completed in 2005. This paper describes current status of the low cost 6-meter breadboard antenna to be used as part of the interferometer and the RF design of the 12-meter antenna.

antennas↗

Infrared Camera Characterization of Bi-Propellant Reaction Control Engines during Auxiliary Propulsion Systems Tests at NASA's White Sands Test Facility in Las Cruces, New Mexico

This paper describes the application of a FUR Systems A40M infrared (IR) digital camera for thermal monitoring of a Liquid Oxygen (LOX) and Ethanol bi-propellant Reaction Control Engine (RCE) during Auxiliary Propulsion System (APS) testing at the National Aeronautics & Space Administration's (NASA) White Sands Test Facility (WSTF) near Las Cruces, New Mexico. Typically, NASA has relied mostly on the use of ThermoCouples (TC) for this type of thermal monitoring due to the variability of constraints required to accurately map rapidly changing temperatures from ambient to glowing hot chamber material. Obtaining accurate real-time temperatures in the JR spectrum is made even more elusive by the changing emissivity of the chamber material as it begins to glow. The parameters evaluated prior to APS testing included: (1) remote operation of the A40M camera using fiber optic Firewire signal sender and receiver units; (2) operation of the camera inside a Pelco explosion proof enclosure with a germanium window; (3) remote analog signal display for real-time monitoring; (4) remote digital data acquisition of the A40M's sensor information using FUR's ThermaCAM Researcher Pro 2.8 software; and (5) overall reliability of the system. An initial characterization report was prepared after the A40M characterization tests at Marshall Space Flight Center (MSFC) to document controlled heat source comparisons to calibrated TCs. Summary IR digital data recorded from WSTF's APS testing is included within this document along with findings, lessons learned, and recommendations for further usage as a monitoring tool for the development of rocket engines.

Holleman, Elizabeth↗