Cold-Point Tropopause Temperature Bias in Reanalyses Modulated By Equatorial Waves

In this reanalysis inter-comparison study, we compare the modeled Cold-point tropopause temperature (CPT from model level data) near the equator to that of multi-mission GNSS-RO within a preliminary time period of 2007-2011. The known reanalysis CPT temperature warm bias is studied relative to the phase of equatorial waves filtered from GNSS-RO at tropopause level. This uncovers a common denominator in the CPT temperature bias behavior in all reanalyses: - When equatorial waves are present, within their cold phase the reanalysis bias is increased by over 1K, i.e. >1K on top of the reanalysis average warm bias. - Within an equatorial wave’s warm phase, the opposite is observed, with the reanalysis CPT temperature bias even being reversed at higher equatorial wave amplitudes, i.e. the modeled CPT becoming too cold in these cases. - With no equatorial wave anomalies present, the reanalysis bias remains at the average reported in previous inter-comparisons that looked at zonal-mean CPT biases. Inertia-Gravity and Mixed Rossby-Gravity waves show this behavior most clearly, Kelvin waves show a similar modulation but with half of the magnitude, and equatorial Rossby wave modulation of CPT reanalysis bias is still apparent but with further decreased magnitude. This hints on a time-space scale-dependence, with medium-smaller-scale and faster equatorial waves influencing CPT reanalysis bias the most. For comparison, the large-scale and slow-moving MJO does not show any of the effects described above. Current work focuses on the data assimilation response of the reanalysis systems, again relative to the equatorial wave’s phases.

Tropopause↗

Cold Ocean Planets: Exoplanet Analogs of Our Solar System’s Icy Moons?

We have calculated total internal heating rates and depths to possible subsurface oceans for 17 planets that were previously characterized as rocky worlds but that are best described as Cold Ocean Planets. These low-mass exoplanets have equilibrium surface temperatures and/or densities that are consistent with icy surfaces and a substantial H2O content. While all planets in our study are likely to be covered in ice, estimated internal heating rates from tidal and radiogenic sources are large enough that they may harbor internal oceans and exhibit explosive cryovolcanism in the form of geyser-like plumes at their surfaces. Several of the icy moons in our solar system may thus serve as small-scale analogs of the Cold Ocean Planets in our study. We find that geological activity rates on these worlds are likely to exceed geological activity rates on Jupiter’s moon Europa and that several planets are likely to experience enhanced geological activity that exceeds that on Io. Owing to these planets’ thin ice shells, their expected high rates of internal heating, and their potential for tidally-induced explosive cryovolcanism, the identification of water vapor absorption features, especially given the expected time-variability of water vapor output during eruptions, could allow for the detection of geyser-like plumes on Trappist-1f, Proxima Cen b, and LHS 1140 b. Our study suggests that Cold Ocean Planets are habitable worlds at which the detection of explosive cryovolcanism could serve as indirect evidence of the presence of oceans beneath a layer of surface ice. Analyses of observational data from next-generation space telescopes and upcoming ground-based extremely large telescopes, and designs for future telescopic missions, should be undertaken with these results in mind.

Lynnae C Quick↗

The use Na, Li, K cations for modification of ZSM-5 zewolite to control hydrocarbon cold-start emission

This paper addresses the problem of controlling hydrocarbon emissions from cold-start of engines by investigating the adsorbents which could adsorb the hydrocarbons at cold temperatures and hold them to 250-300 ?. The materials, that has been studied, are based on the modification of ZSM-5 (SiO{sub 2}/Al{sub 2}O{sub 3} = 35) zeolite with Li, K, Na cations. It has been shown that the introduction of Li, Na and K in an amount that is equivalent to the content of Al in zeolite results in occurrence of toluene temperature desorption peaks at high-temperatures. The toluene temperature desorption curves for 5%Li-ZSM-5 and 2.3%Na-ZSM-5 zeolites are identical and have peak toluene desorption rate between 200 to 400 ?. Upon analysis of toluene adsorption isotherms for 2.3%Na-ZSM-5 and 5%Li-ZSM-5, it was concluded that the toluene diffusion inside of the modified zeolites channels is extremely slow and the sorption capacity of 2.3%Na-ZSM-5 is higher than with 5%Li-ZSM-5. The 2.3%Na-ZSM-5 didn't change toluene temperature programmed desorption (TPD) rate of curve after the treatment in environment with 10% ?{sub 2}? at 750-800 ? for about 28 h. The 2.3%Na-ZSM-5 zeolite is very promising as adsorbent to control the cold-start hydrocarbon emissions.

42 ENGINEERING↗

New analogies between extreme QCD and cold atoms

We discuss two new analogies between extreme QCD and cold atoms. One is the analogue of 'hard probes' in cold atoms. The other is the analogue of 'quark-hadron continuity' in cold atoms.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Cold Climate and Retrofit Applications for Air-to-Air Heat Pumps

Air source heat pumps (ASHP) including air-to-air ASHPs are easily applied to buildings almost anywhere for new construction as well as retrofits or renovations. They are widespread in milder climate regions but their use in cold regions is hampered due to low heating efficiency and capacity at cold outdoor temperatures. Retrofitting air-to-air ASHPs to existing buildings is relatively easy if the building already has an air distribution system. For buildings without such systems alternative approaches are necessary. Examples are ductless, minisplit heat pumps or central heat pumps coupled to small diameter, high velocity (SDHV) air distribution systems. This article presents two subjects: 1) a summary of R&D investigations aimed at improving the cold weather performance of ASHPs, and 2) a brief discussion of building retrofit options using air-to-air ASHP systems.

Baxter, Van D↗

SEASONAL PERFORMANCE SIMULATION OF A GAS-FIRED CHEMISORPTION HEAT PUMP FOR RESIDENTIAL HEATING IN COLD CLIMATE

The gas-fired chemisorption heat pump (CSHP) is a promising technology for high-efficiency cold-climate residential heating. The CSHP utilizes the heat of reversible chemical reactions between sorbent and refrigerant to extract heat from cold ambient and supply high-temperature heat to the indoors. The efficiency of CSHP depends on the ambient and heat rejection temperatures. This study evaluates the seasonal performance of a CSHP by first develop a dynamic system model to generate a performance map for various ambient and heat-supply temperatures; then the bin method is used to evaluate the CSHP seasonal performance in two cold-climate locations for space and water heating.

Yang, Zhiyao↗

Residential Cold-Climate Heat Pump Technology Challenge

Cold-climate heat pumps (CCHPs) provide both space heating and cooling for homes, and incorporate advanced features that allow for improved heating capacity and efficiency at cold weather conditions compared with traditional heat pumps. To advance the adoption of CCHP technologies, DOE is launching the Cold-Climate Heat Pump Technology Challenge as part of the Initiative for Better Energy, Emissions, and Equity (E3 Initiative).

Space conditioning, water heating, HVAC, competiti↗

Ultra-compact configurable double-sided manifold micro-channel cold plate

A configurable, double sided, manifold micro-channel cold plate includes a one or more manifold micro-channel cold plate cells. Each cold plate cell includes a manifold body, a manifold insert, a plurality of heat sinks, and a plurality of longitudinal openings configured for fluidic communication with the fluid channels. The manifold body has fluid channels to permit flow of a fluid coolant. The manifold insert has a plurality of manifold insert fluid channels, and is configured for receipt in the one of the modular body recesses. The heat sinks are configured for receipt in the modular body recesses, and include an impingement surface configured for fluidic communication with the manifold insert fluid channels, and a heat transfer surface for thermal communication with one or more heat generating devices.

Zhou, Feng↗

Study of effect of PWR cold leg temperature gradient on reactor core condition

Effects of temperature and flow gradients in Westinghouse designed three-loop Pressurized Water Reactor (PWR) cold legs, the piping between the main coolant pump and the reactor vessel, were evaluated using Computational Fluid Dynamics (CFD) code STAR CCM+ and coupled neutronic and thermal-hydraulic (T/H) code system VERA. In the parametric study, several symmetric and asymmetric temperature gradients that were significantly larger than those observed from plant measurements were applied to the cold leg inlets for comparison with the base case without any temperature gradient. A CFD model using the STAR-CCM+ code was developed for a portion of the RCS region between the Reactor Coolant Pump (RCP) and the core inlet based on previously validated modeling approach. The CFD simulation results were processed for the temperature and flow rate distributions at the core inlet as input to the VERA calculations. The VERA code system consists of COBRA-TF (CTF) for thermal-hydraulics, MPACT for reactor physics and neutron transport, and ORIGEN for isotopic depletion. The VERA model was for depletion calculations of a high-burnup loading pattern with the reactor core in pin-by-pin and subchannel resolution. The results of the study indicate that the postulated temperature gradients within the PWR cold legs do not result in any significant changes in the core inlet temperature distributions and the core power distributions during the reactor operation. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Experimental Evaluation of a High-Performance Cold-Climate Heat Pump Using Tandem Vapor-Injection Compressors

A high-performance cold-climate heat pump (CCHP) was developed and experimentally validated through comprehensive laboratory and field testing. The system utilized two equal-size tandem vapor-injection (VI) compressors with an inter-stage flash tank to improve efficiency and capacity retention under subfreezing conditions. Laboratory testing was conducted on a 3-ton prototype in a controlled environmental chamber equipped with calibrated thermocouples, refrigerant-side mass flow and pressure transducers, and precision airflow measurement for energy balance verification. The prototype achieved heating coefficients of performance (COPs) of 4.4 at 47 °F, 3.1 at 17 °F, and 2.0 at –13 °F, while maintaining 88% of its rated heating capacity at –13°F. These results confirm strong low-temperature performance and indicate the potential for significant reductions in electric resistance backup use. A field prototype was installed and monitored in a residential building in Fairbanks, Alaska, during a heating season. Instrumentation included real-time power, temperature, and refrigerant state measurements to evaluate performance under dynamic outdoor conditions. The heat pump operated reliably down to –30 °F, delivering 75% of its rated heating capacity with a COP of 1.8, while maintaining stable operation, effective defrost control, and indoor comfort without auxiliary heating. The combined laboratory and field results demonstrate that the tandem VI compressor configuration provides a practical and energy-efficient approach for residential heat pumps designed for cold and very cold climate regions.

Hu, Yifeng [ORNL] (ORCID:0000000242875185)↗

Magnetohydrodynamic Simulations of Disk GalaxyFormation: the Magnetization of The Cold and Warm Medium

Using magnetohydrodynamic (MHD) adaptive mesh refinement simulations, we study the formation and early evolution of disk galaxies with a magnetized interstellar medium. For a 10{sup 10} M{sub {circle_dot}} halo with initial NFW dark matter and gas profiles, we impose a uniform 10{sup -9} G magnetic field and follow its collapse, disk formation and evolution up to 1 Gyr. Comparing to a purely hydrodynamic simulation with the same initial condition, we find that a protogalactic field of this strength does not significantly influence the global disk properties. At the same time, the initial magnetic fields are quickly amplified by the differentially rotating turbulent disk. After the initial rapid amplification lasting {approx} 500 Myr, subsequent field amplification appears self-regulated. As a result, highly magnetized material begin to form above and below the disk. Interestingly, the field strengths in the self-regulated regime agrees well with the observed fields in the Milky Way galaxy both in the warm and the cold HI phase and do not change appreciably with time. Most of the cold phase shows a dispersion of order ten in the magnetic field strength. The global azimuthal magnetic fields reverse at different radii and the amplitude declines as a function of radius of the disk. By comparing the estimated star formation rate (SFR) in hydrodynamic and MHD simulations, we find that after the magnetic field strength saturates, magnetic forces provide further support in the cold gas and lead to a decline of the SFR.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

COLD-START CHARACTERISTICS OF POLYMER ELECTROLYTE FUEL CELLS

In this paper, we investigate the electrochemical reaction kinetics, species transport, and solid water dynamics in a polymer electrolyte fuel cell (PEFC) during cold start. A simplified analysis is developed to enable the evaluation of the impact of ice volume fraction on cell performance during cold-start. Supporting neutron imaging data are also provided to reveal the real-time water evolution. Temperature-dependent voltage changes due to the reaction kinetics and ohmic loss are also analyzed based on the ionic conductivity of the membrane at subfreezing temperature. The analysis is valuable for the fundamental study of PEFC cold-start.

30 DIRECT ENERGY CONVERSION↗

Pseudo one-dimensional analysis of polymer electrolyte fuel cell cold-start

This paper investigates the electrochemical kinetics, oxygen transport, and solid water formation in polymer electrolyte fuel cell (PEFC) during cold start. Following [Yo Wang, J. Electrochem. Soc., 154 (2007) B1041-B1048], we develop a pseudo one-dimensional analysis, which enables the evaluation of the impact of ice volume fraction and temperature variations on cell performance during cold-start. The oxygen profile, starvation ice volume fraction, and relevant overpotentials are obtained. This study is valuable for studying the characteristics of PEFC cold-start.

36 MATERIALS SCIENCE↗

2013 Radiological Monitoring Results Associated with the Advanced Test Reactor Complex Cold Waste Pond

This report summarizes radiological monitoring performed of the Idaho National Laboratory Site’s Advanced Test Reactor Complex Cold Waste wastewater prior to discharge into the Cold Waste Pond and of specific groundwater monitoring wells associated with the Industrial Wastewater Reuse Permit (#LA-000161-01, Modification B). All radiological monitoring is performed to fulfill Department of Energy requirements under the Atomic Energy Act.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Residential Cold Climate Heat Pump (CCHP) w/Variable Speed Technology

This report summarizes the results of a three year program awarded to Unico, Inc. to commercialize a residential cold climate heat pump. Several designs were investigated. Compressors were selected using analysis from Oakridge National Laboratories followed by prototype construction and lab testing in a specially built environmental chamber capable of reaching -30°F. The initial design utilized two variable speed compressors in series with very good capacity results and acceptable efficiency at very cold temperatures. The design was then modified to reduce cost and complexity by redesigning the system using three dual-stage compressors: two in parallel followed by one in series. Extensive testing found significant challenge with oil management, reliability, weight and cost which prevented the system from being fully commercialized. Further analysis of other conceptual designs indicated that these challenges could be overcome in the future.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

NorthernSTAR Project Overcoat: Exterior Insulation Strategies for 1.5-Story Roof Applications in Cold Climates

This is a repository for all NorthernSTAR Overcoat insulation retrofit projects. Both houses received Overcoat insulation retrofit on roof only, performed by Cocoon Insulation. 1 - St. Louis Park house - St. Louis Park, MN 2 - Edina house - Edina, MN In this second study, the team wished to analyze the before and after air-tightness data from roof only ETMMS retrofits on 1.5-story homes in cold and very cold climates. To identify homes to analyze, we reached out to our national network of energy professionals, home performance contractors, and general contractors who had expressed interest in promoting roof-only External Thermal Moisture Management System (ETMMS) to clients. Five projects by three contractors were submitted for consideration as they were being done to mitigate severe ice dams for homeowners. Only two of the five projects followed a roof only ETMMS protocol. Data from the other three projects, however, were reviewed with the air-tightness data of 250 roof-only, interior-applied energy retrofits on 1.5-story homes provided by three NorthernSTAR industry partners. These data represent homes in the general market as well as homes that were part of the state of Minnesota weatherization program.

adhered applied membrane↗

An LES Survey of Cold-Air Outbreaks Spanning ACTIVATE and COMBLE

Two recent field campaigns offer unique new opportunities to survey coupled aerosol and cloud processes operating within cold-air outbreaks (CAOs). NASA's 2019-2023 Aerosol Cloud meTeorology Interactions oVer the western Atlantic Experiment (ACTIVATE) project provided airborne in situ and remote sensing observations in multiple CAOs off the central US Eastern Seaboard. Contemporaneously, DOE's 2019-2020 Cold-air Outbreaks in the Marine Boundary Layer Experiment (COMBLE) provided continuous ground-based in situ and remote sensing measurements during hundreds of hours of CAO conditions at two sites flanking the Norwegian Sea. Here we highlight lessons learned from contrasting sets of aerosol-aware Lagrangian large-eddy simulation case studies derived from each campaign, as well as outstanding uncertainties. Cases simulated include all of the most extensively sampled CAO flights during ACTIVATE, and a wide range of CAO strengths and mesoscale structures during COMBLE. Each case study is also suitable for simulation with large-scale models in single-column model mode or with a limited-domain approach using periodic boundary conditions. We seek to address the central question: what microphysical process pathways control the Lagrangian evolution of surface and top-of-atmosphere radiative fluxes under ACTIVATE and COMBLE conditions? Many science team members, co-investigators, and collaborators will be gratefully acknowledged in association with their contributions to making this work possible.