Search NASA⌕ Search

SEARCH · Search NASA

Results for “computerized procedures”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 721 records · Page 40

SISTec: Mathematical Calibration of Large Clearance Monitors - 18265

One major path for clearance of large amount of waste arising from the decommission of nuclear power plants is based on measurement with large clearance monitors (also known as free release measurement facilities). These devices utilize multi-detector plastic scintillator arrays (large clearance monitors can consist of up to 24 plastic scintillators) to offer both, extremely low minimum detectable activities (MDA) and short measurement times for waste packages weighing up to one metric ton. However, a major problem with these devices is to obtain nuclide specific efficiencies, especially for geometrically complex large waste packages. Normal procedure for estimating the efficiency is to device dummy waste packages and attach point sources with well-known activities to unfavourable positions in these packages. In accordance with this procedure, calibration factors can be derived in a radiological conservative way. Devising such test dummies is not always possible and the procedure is prone to generating large measurement uncertainties. In this publication, we propose a new method to derive calibration factors by means of the Los Alamos National Laboratory (LANL) simulation tool Monte Carlo N-Particle (MCNP) and a statistical-phenomenological model for the detector characterization. In a multi-step approach, first the detector response for a distribution of activity in a waste package is calculated and subsequently the detectors are mathematically characterized. Applying state of the art statistical and optimizing procedures, parameters for the detector response are derived in a self-consistent way. This also allows to rigorously propagate the uncertainties to the final calculated calibration factors according to the Guide to the Expression of Uncertainty in Measurement (GUM supplement 1). To validate the derived parameters for the detector characterization a minimally invasive experimental setup was devised and installed into the large clearance monitor. It consisted of an aluminum swivel arm which could position point sources to the relevant coordinates. The so collected measurement data not only allowed to investigate the precision of the calculated calibration factors, but also to probe the location of concentrated activity sources in the waste package. Furthermore, data on measurements with dummy waste packages were collected to test the reproducibility of well-known calibration factors. We present the software tool SIStec, which will provide an intuitive user-interface to generate and simulate waste package models and execute the above-mentioned method. Using SIStec, different scenarios for the distribution of activity in the waste package can be probed. This will also allow to optimize the clearance process on various levels. For example, measurement time for pre-measurements can be reduced in exchange for unfavourable calibration factors, which would still allow to meet the regulator limits for clearance. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Model-independent limits and constraints on extended theories of gravity from cosmic reconstruction techniques

The onset of dark energy domination depends on the particular gravitational theory driving the cosmic evolution. Model independent techniques are crucial to test the both the present ΛCDM cosmological paradigm and alternative theories, making the least possible number of assumptions about the Universe. In this paper we investigate whether cosmography is able to distinguish between different gravitational theories, by determining bounds on model parameters for three different extensions of General Relativity, namely quintessence, F (Τ) and f ( R ) gravitational theories. We expand each class of theories in powers of redshift z around the present time, making no additional assumptions. This procedure is an extension of previous work and can be seen as the most general approach for testing extended theories of gravity through the use of cosmography. In the case of F (Τ) and f ( R ) theories, we show that some assumptions on model parameters often made in previous works are superfluous or even unjustified. We use data from the Union 2.1 supernovae catalogue, baryonic acoustic oscillation data and H ( z ) differential age compilations, which probe cosmology on different scales of the cosmological evolution. We perform a Monte Carlo analysis using a Metropolis-Hastings algorithm with a Gelman-Rubin convergence criterion, reporting 1-σ and 2-σ confidence levels. To do so, we perform two distinct fits, assuming only data within z < 1 first and then without limitations in redshift. We obtain the corresponding numerical intervals in which coefficients span, and find that the data is compatible the ΛCDM limit of all three theories at the 1-σ level, while still compatible with quite a large portion of parameter space. We compare our results to the truncated ΛCDM paradigm, demonstrating that our bounds divert from the expectations of previous works, showing that the permitted regions of coefficients are significantly modified and in general widened with respect to values usually reported in the existing literature. Finally, we test the extended theories through the Bayesian selection criteria AIC and BIC.

79 ASTRONOMY AND ASTROPHYSICS↗

SU-F-T-50: Evaluation of Monte Carlo Simulations Performance for Pediatric Brachytherapy Dosimetry

Purpose: Pediatric tumors are generally treated with multi-modal procedures. Brachytherapy can be used with pediatric tumors, especially given that in this patient population low toxicity on normal tissues is critical as is the suppression of the probability for late malignancies. Our goal is to validate the GATE toolkit on realistic brachytherapy applications, and evaluate brachytherapy plans on pediatrics for accurate dosimetry on sensitive and critical organs of interest. Methods: The GATE Monte Carlo (MC) toolkit was used. Two High Dose Rate (HDR) 192Ir brachytherapy sources were simulated (Nucletron mHDR-v1 and Varian VS2000), and fully validated using the AAPM and ESTRO protocols. A realistic brachytherapy plan was also simulated using the XCAT anthropomorphic computational model .The simulated data were compared to the clinical dose points. Finally, a 14 years old girl with vaginal rhabdomyosarcoma was modelled based on clinical procedures for the calculation of the absorbed dose per organ. Results: The MC simulations resulted in accurate dosimetry in terms of dose rate constant (Λ), radial dose gL(r) and anisotropy function F(r,θ) for both sources.The simulations were executed using ∼1010 number of primaries resulting in statistical uncertainties lower than 2%.The differences between the theoretical values and the simulated ones ranged from 0.01% up to 3.3%, with the largest discrepancy (6%) being observed in the dose rate constant calculation.The simulated DVH using an adult female XCAT model was also compared to a clinical one resulting in differences smaller than 5%. Finally, a realistic pediatric brachytherapy simulation was performed to evaluate the absorbed dose per organ and to calculate DVH with respect to heterogeneities of the human anatomy. Conclusion: GATE is a reliable tool for brachytherapy simulations both for source modeling and for dosimetry in anthropomorphic voxelized models. Our project aims to evaluate a variety of pediatric brachytherapy schemes using a population of pediatric phantoms for several pathological cases. This study is part of a project that has received funding from the European Union Horizon2020 research and innovation programme under the MarieSklodowska-Curiegrantagreement.No691203.The results published in this study reflect only the authors view and the Research Executive Agency (REA) and the European Commission is not responsible for any use that may be madeof the information it contains.

60 APPLIED LIFE SCIENCES↗

Development of bimetallic (Zn@Au) nanoparticles as potential PET-imageable radiosensitizers

Purpose: Gold nanoparticles (GNPs) are being investigated actively for various applications in cancer diagnosis and therapy. As an effort to improve the imaging of GNPs in vivo, the authors developed bimetallic hybrid Zn@Au NPs with zinc cores and gold shells, aiming to render them in vivo visibility through positron emission tomography (PET) after the proton activation of the zinc core as well as capability to induce radiosensitization through the secondary electrons produced from the gold shell when irradiated by various radiation sources. Methods: Nearly spherical zinc NPs (∼5-nm diameter) were synthesized and then coated with a ∼4.25-nm gold layer to make Zn@Au NPs (∼13.5-nm total diameter). 28.6 mg of these Zn@Au NPs was deposited (∼100 μm thick) on a thin cellulose target and placed in an aluminum target holder and subsequently irradiated with 14.15-MeV protons from a GE PETtrace cyclotron with 5-μA current for 5 min. After irradiation, the cellulose matrix with the NPs was placed in a dose calibrator to assess the induced radioactivity. The same procedure was repeated with 8-MeV protons. Gamma ray spectroscopy using an high-purity germanium detector was conducted on a very small fraction (<1 mg) of the irradiated NPs for each proton energy. In addition to experimental measurements, Monte Carlo simulations were also performed with radioactive Zn@Au NPs and solid GNPs of the same size irradiated with 160-MeV protons and 250-kVp x-rays. Results: The authors measured 168 μCi of activity 32 min after the end of bombardment for the 14.15-MeV proton energy sample using the {sup 66}Ga setting on a dose calibrator; activity decreased to 2 μCi over a 24-h period. For the 8-MeV proton energy sample, PET imaging was additionally performed for 5 min after a 12-h delay. A 12-h gamma ray spectrum showed strong peaks at 511 keV (2.05 × 10{sup 6} counts) with several other peaks of smaller magnitude for each proton energy sample. PET imaging showed strong PET signals from mostly decaying {sup 66}Ga. The Monte Carlo results showed that radioactive Zn@Au NPs and solid GNPs provided similar characteristics in terms of their secondary electron spectra when irradiated. Conclusions: The Zn@Au NPs developed in this investigation have the potential to be used as PET-imageable radiosensitizers for radiotherapy applications as well as PET tracers for molecular imaging applications.

60 APPLIED LIFE SCIENCES↗

SU-F-207-14: Low Contrast Detectability (LCD) at Different Diagnostic Reference Levels for Adult Abdominal CT Procedures

Purpose Using diagnostic reference levels (DRL) to optimize CT protocols has potential to reduce radiation dose and meet regulatory requirements. However, DRL’s tend to be misconstrued as dose limits, are typically designed for specific patient populations, and are assumed to have acceptable image quality (AIQ) associated with them. To determine the image quality that is associated with established DRL’s for adult abdominal CT studies, a LCD phantom study was employed. Methods: A CT phantom (CIRS) containing three columns of 7 spherical targets, ranging from 10mm to 2.4 mm, that are 5, 10, and 20 HU below the background (HUBB) matrix was scanned with a GE HD750 64 slice scanner. The phantom was scanned at the NEXT 2006 25th CTDIvol of 12 mGy, the NCRP 172 achievable dose (AD) CTDIvol of 17 mGy and 75th CTDIvol of 25 mGy and at the ACR recommended CTDIvol of 25 mGy. It was also scanned at a CTDIvol 20% greater than the AD at 20 mGy and the ACR maximum threshold of 30 mGy. Results: At the NEXT 2006 25th percentile CTDIvol of 12 mGy, a 6.3 mm low contrast lesion was detectable in the 20 HUBB; 6.3 mm in the 10 HUBB and 10 mm in the 5 HUBB column. Increasing the CTDIvol to the NCRP 172 AD of 17 mGy, an additional 4.8 mm lesion was visualized in the 20 HUBB column. At 20 mGy, an additional 4.8 mm lesion was detectable in the 10 HUBB column. No further lesions were visible between 20 and 30 mGy. However, conspicuity of all lesions increased with each additional step up in CTDI. Conclusion: Optimizing radiation dose to achieve AIQ is a critical aspect of any dose optimization committee. Hence, judicious monitoring of radiation exposure to patients has to be balanced with diagnostic image quality.

60 APPLIED LIFE SCIENCES↗

Is Routine Splenectomy Justified for All Left-Sided Pancreatic Cancers? Histological Reappraisal of Splenic Hilar Lymphadenectomy

Background: Although splenectomy is recommended during resection for left-sided resectable pancreatic ductal adenocarcinoma (PDAC) to perform lymphadenectomy of station 10 (splenic hilum), no level I evidence justifies this procedure. This study aims to evaluate the rate of lymph node (LN) and contiguous involvement of the splenic hilum in resectable distal PDAC. Methods: We retrospectively reviewed all patients who underwent splenopancreatectomy for PDAC in the past 10 years. Station 10 LN were routinely isolated, and all corresponding microscopic slides were reinterpreted by a pathologist. The computed tomography (CT) results of patients with tumoral involvement of the spleen or splenic hilum by contiguity (TISOSH) and ≤ 10 mm between the tumor and spleen on pathology were blindly reviewed by two radiologists to evaluate CT for diagnosis of TISOSH. Results: We included 110 consecutive patients, including 104 with analyzable station 10 LN. The tumor was N+ in 58 (53%) patients. The median number of LN identified at station 10 was 2.0 ± 3.0. No station 10 LNs were detected in 42 (40%) patients. No patients had tumor-positive LN at station 10. TISOSH was found in nine (8%) patients, and was significantly associated with tail location (p = 0.001), tumor size (p = 0.005), and multivisceral involvement (p = 0.015). For diagnosis of TISOSH, the sensitivity and specificity of CT were respectively 89% and 95% for radiologist 1 and 89% and 100% for radiologist 2. Conclusions: Splenic preservation during resection of distal PDAC may be an option in selected patients with body tumors and no suspected splenic or splenic hilum involvement on preoperative CT.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Virtual Guidance of Percutaneous Transthoracic Needle Biopsy with C-Arm Cone-Beam CT: Diagnostic Accuracy, Risk Factors and Effective Radiation Dose

Purpose: C-arm cone-beam computed tomography-guided transthoracic lung core needle biopsy (CBCT-CNB) is a safe and accurate procedure for the evaluation of patients with pulmonary nodules. The purpose of our study was to evaluate the diagnostic performance, complication rates and effective radiation dose of CBCT-CNB with virtual guidance. Materials and Methods: We retrospectively collected data regarding 375 CBCT-CNBs performed with virtual guidance (XperGuide—Philips Healthcare, Best, The Netherlands) from January 2010 to June 2015 on 355 patients (mean age, 68.1 years ± 11.8; age range, 31–88 years). Patients were divided into groups and compared based on the diagnostic failure and lesion size (15 mm cutoff). Diagnostic performance, complication rate and effective radiation dose were investigated. Variables influencing diagnostic performance and complications were assessed using Student’s T test and Pearson’s χ{sup 2} test. Results: The sensitivity, specificity, positive and negative predictive value and accuracy for patients subjected to CNBs were 96.8%, 100%, 100%, 100% and 97.2%, respectively. Considering risk factors for pneumothorax, no significant differences were found regarding patient and lesion characteristics. Perilesional hemorrhage occurred more frequently in older patients (p = 0.046) and in smaller lesions (p = 0.001). Hemoptysis was significantly more frequent in patients with perilesional hemorrhage (p = 0.01). Mean effective radiation dose in CBCT-CNB was 7.12 ± 8.78 mSv. Conclusions: CBCT-CNB combined with virtual guidance is a reliable and accurate technique that allows exact localization of pulmonary lesions, effective preprocedural planning and real-time fluoroscopy altogether.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

THE SHAPES OF MILKY WAY SATELLITES: LOOKING FOR SIGNATURES OF TIDAL STIRRING

We study the shapes of Milky Way satellites in the context of the tidal stirring scenario for the formation of dwarf spheroidal galaxies. The standard procedures used to measure shapes involve smoothing and binning of data and thus may not be sufficient to detect structural properties such as bars, which are usually subtle in low surface brightness systems. Taking advantage of the fact that in nearby dwarfs photometry of individual stars is available, we introduce discrete measures of shape based on the two-dimensional inertia tensor and the Fourier bar mode. We apply these measures of shape first to a variety of simulated dwarf galaxies formed via tidal stirring of disks embedded in dark matter halos and orbiting the Milky Way. In addition to strong mass loss and randomization of stellar orbits, the disks undergo morphological transformation that typically involves the formation of a triaxial bar after the first pericenter passage. These tidally induced bars persist for a few Gyr before being shortened toward a more spherical shape if the tidal force is strong enough. We test this prediction by measuring in a similar way the shape of nearby dwarf galaxies, satellites of the Milky Way. We detect inner bars in Ursa Minor, Sagittarius, Large Magellanic Cloud, and possibly Carina. In addition, 6 out of 11 dwarfs that we studied show elongated stellar distributions in the outer parts that may signify transition to tidal tails. We thus find the shapes of Milky Way satellites to be consistent with the predictions of the tidal stirring model.

79 ASTRONOMY AND ASTROPHYSICS↗

Role of Intra- or Periprostatic Calcifications in Image-Guided Radiotherapy for Prostate Cancer

Purpose: Image-guided radiotherapy (IGRT) allows more precise localization of the prostate, thus minimizing errors resulting from organ motion and set-up during treatment of prostate cancer. Using megavoltage cone-beam computed tomography (MVCBCT), references such as bones, the prostate itself or implanted fiducial markers can be used as surrogates to correct patient positioning immediately before each treatment fraction. However, the use of fiducials requires an invasive procedure and may increase costs. We aimed to assess whether intra- or periprostatic calcifications (IPC) could be used as natural fiducials. Methods and Materials: Data on patients treated with IGRT for prostate cancer with clearly visible IPC and implanted fiducials in both planning CT and MVCBCT images were reviewed. IPC were classified as central when inside the prostate and peripheral when within the planning target volume. Daily deviations in lateral, longitudinal, and vertical directions from baseline positioning using fiducials and using IPC were compared. Results: A total of 287 MVCBCT images were obtained and analyzed from 10 patients. The mean {+-} standard deviation daily deviation (mm) in the lateral, longitudinal, and vertical coordinates were 0.55 {+-} 3.11, 0.58 {+-} 3.45, and -0.54 {+-} 4.03, respectively, for fiducials, and 0.72 {+-} 3.22, 0.63 {+-} 3.58, and -0.69 {+-} 4.26, for IPC. The p values for comparisons (fiducials vs. IPC) were 0.003, 0.653, and 0.078 for lateral, longitudinal, and vertical coordinates, respectively. When cases with central IPC were analyzed (n = 7), no significant difference was found in such comparisons. Central IPC and fiducials exhibited a similar pattern of displacement during treatment, with equal values for daily displacements in the three directions for more than 90% of measurements. Conclusions: Our data suggest that centrally located IPC may be used as natural fiducials for treatment positioning during IGRT for prostate cancer, with potential reductions in the risks and costs associated with fiducial implantation.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-E-I-12: Flexible Geometry Computed Tomography

Purpose: The concept separates the mechanical connection between the radiation source and detector. This design allows the trajectory and orientation of the radiation source/detector to be customized to the object that is being imaged. This is in contrast to the formulaic rotation-translation image acquisition of conventional computed tomography(CT).Background/significance:CT devices that image a full range of: anatomy, patient populations, and imaging procedures are large. The root cause of the expanding size of comprehensive CT is due to the commitment to helical geometry that is hardwired into the image reconstruction. FGCT extends the application of alternative reconstruction techniques, i.e. tomosynthesis, by separating the two main components— radiation source and detector— and allow for 6 degrees of freedom motion for radiation source, detector, or both. The image acquisition geometry is then tailored to how the patient/object is positioned. This provides greater flexibility on the position and location that the patient/object is being imaged. Additionally, removing the need of a rotating gantry reduces the footprint so that CT is more mobile and more available to move to where the patient/object is at, instead of the other way around. Methods: As proof-of-principle, a reconstruction algorithm is designed to produce FGCT images. Using simulated detector data, voxels intersecting a line drawn between the radiation source and an individual detector are traced and modified using the detector signal. The detector signal is modified to compensate for changes in the source to detector distance. Adjacent voxels are modified in proportion to the detector signal, providing a simple image filter. Results: Image-quality from the proposed FGCT reconstruction technique is proving to be a challenge, producing hardily recognizable images from limited projections angles. Conclusion: Preliminary assessment of the reconstruction technique demonstrates the inevitable tradeoff of producing meaningful image-quality verses the practicality of how to obtain sufficient image data.

60 APPLIED LIFE SCIENCES↗

Effects of Varicocele Treatment on Sperm Conventional Parameters: Surgical Varicocelectomy Versus Sclerotherapy

Introduction: Varicocele is often associated with impaired sperm parameters. Different procedures have been developed for varicocele treatment. The aim of this study was to evaluate the effects of varicocele treatment on conventional sperm parameters. Materials and Methods: We compared two different techniques of intervention: surgical varicocelectomy and sclerotherapy. We also evaluated the number of varicocele recurrences and the pregnancy rate. We included 102 patients (mean age 29.8 ± 0.8 years) with ultrasound diagnosis of varicocele. We excluded patients whose ultrasound evaluation and/or sperm parameters were not known before and after varicocele correction. We divided the patients (excluding 8 with azoospermia) into two subgroups: surgical varicocelectomy (n = 44) and sclerotherapy (n = 50). For each patient, we compared conventional sperm parameters before and after varicocele correction. Results: After varicocele correction, we found a significant improvement in sperm concentration, total count and total motility. Considering the two subgroups, baseline sperm parameters did not differ significantly. Sperm concentration and total count increased significantly after varicocele correction by varicocelectomy. Varicocele correction by sclerotherapy resulted in a significant increase in sperm concentration, progressive and total motility. We found varicocele recurrence in 32% of patients who underwent varicocelectomy and in 19.7% of patients undergoing sclerotherapy. The pregnancy rate was higher after sclerotherapy (28%) than after surgical varicocelectomy (13%). Conclusion: Varicocele treatment must be recommended when other causes of infertility have been treated. Our results suggest the use of sclerotherapy for varicocele repair. Level of Evidence: 2 b.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-F-T-242: A Method for Collision Avoidance in External Beam Radiation Therapy

Purpose: We proposed a method for collision avoidance (CA) in external beam radiation therapy (EBRT). The method encompasses the analysis of all positions of the moving components of the beam delivery system such as the treatment table and gantry, including patient specific information obtained from the CT images. This method eliminates the need for time-consuming dry-runs prior to the actual treatments. Methods: The QA procedure for EBRT requires that the collision should be checked prior to treatment. We developed a system capable of a rigorous computer simulation of all moving components including positions of the couch and gantry during the delivery, position of the patients, and imaging equipment. By running this treatment simulation it is possible to quantify and graphically represent all positions and corresponding trajectories of all points of the moving parts during the treatment delivery. The development of the workflow for implementation of the CA includes several steps: a) derivation of combined dynamic equation of motion of the EBRT delivery systems, b) developing the simulation model capable of drawing the motion trajectories of the specific points, c) developing the interface between the model and the treatment plan parameters such as couch and gantry parameters for each field. Results: The patient CT images were registered to the treatment couch so the patient dimensions were included into the simulation. The treatment field parameters were structured in the xml-file which was used as the input into the dynamic equations. The trajectories of the moving components were plotted on the same graph using the dynamic equations. If the trajectories intersect that was the signal that collision exists. Conclusion: This CA method was proved to be effective in the simulation of treatment delivery. The proper implementation of this system can potentially improve the QA program and increase the efficacy in the clinical setup.

60 APPLIED LIFE SCIENCES↗

SU-E-I-21: Dosimetric Characterization and Image Quality Evaluation of the AIRO Mobile CT Scanner

Purpose: The AIRO Mobile CT system was recently introduced which overcomes the limitations from existing CT, CT fluoroscopy, and intraoperative O-arm. With an integrated table and a large diameter bore, the system is suitable for cranial, spine and trauma procedures, making it a highly versatile intraoperative imaging system. This study is to investigate radiation dose and image quality of the AIRO and compared with those from a routine CT scanner. Methods: Radiation dose was measured using a conventional 100mm pencil ionization chamber and CT polymethylmetacrylate (PMMA) body and head phantoms. Image quality was evaluated with a CATPHAN 500 phantom. Spatial resolution, low contrast resolution (CNR), Modulation Transfer Function (MTF), and Normalized Noise Power Spectrum (NNPS) were analyzed. Results: Under identical technique conditions, radiation dose (mGy/mAs) from the AIRO mobile CT system (AIRO) is higher than that from a 64 slice CT scanner. MTFs show that both Soft and Standard filters of the AIRO system lost resolution quickly compared to the Sensation 64 slice CT. With the Standard kernel, the spatial resolutions of the AIRO system are 3lp/cm and 4lp/cm for the body and head FOVs, respectively. NNPSs show low frequency noise due to ring-like artifacts. Due to a higher dose in terms of mGy/mAs at both head and body FOV, CNR of the AIRO system is higher than that of the Siemens scanner. However detectability of the low contrast objects is poorer in the AIRO due to the presence of ring artifacts in the location of the targets. Conclusion: For image guided surgery applications, the AIRO has some advantages over a routine CT scanner due to its versatility, large bore size, and acceptable image quality. Our evaluation of the physical performance helps its future improvements.

60 APPLIED LIFE SCIENCES↗

SU-E-T-04: 3D Dose Based Patient Compensator QA Procedure for Proton Radiotherapy

Purpose: In proton double-scattering radiotherapy, compensators are the essential patient specific devices to contour the distal dose distribution to the tumor target. Traditional compensator QA is limited to checking the drilled surface profiles against the plan. In our work, a compensator QA process was established that assess the entire compensator including its internal structure for patient 3D dose verification. Methods: The fabricated patient compensators were CT scanned. Through mathematical image processing and geometric transformations, the CT images of the proton compensator were combined with the patient simulation CT images into a new series of CT images, in which the imaged compensator is placed at the planned location along the corresponding beam line. The new CT images were input into the Eclipse treatment planning system. The original plan was calculated to the combined CT image series without the plan compensator. The newly computed patient 3D dose from the combined patientcompensator images was verified against the original plan dose. Test plans include the compensators with defects intentionally created inside the fabricated compensators. Results: The calculated 3D dose with the combined compensator and patient CT images reflects the impact of the fabricated compensator to the patient. For the test cases in which no defects were created, the dose distributions were in agreement between our method and the corresponding original plans. For the compensator with the defects, the purposely changed material and a purposely created internal defect were successfully detected while not possible with just the traditional compensator profiles detection methods. Conclusion: We present here a 3D dose verification process to qualify the fabricated proton double-scattering compensator. Such compensator detection process assesses the patient 3D impact of the fabricated compensator surface profile as well as the compensator internal material and structure changes. This research receives funding support from CURA Medical Technologies.

60 APPLIED LIFE SCIENCES↗

Numerical and Experimental Investigations of Polyurethane Foam for Use as Cask Impact Limiter in Accidental Drop Scenarios - 12099

Rigid, closed-cell polyurethane foams are frequently used as cask impact limiters in nuclear materials and hazardous waste transport due to their high energy-absorption potential. When assessing the cask integrity in accidental scenarios based on numerical simulations, a description of the foam damping properties is required for different strain rates and for a wide temperature range with respect to waste heat generation in conjunction with critical operating and environmental conditions. Implementation and adaption of a respective finite element material model strongly relies on an appropriate experimental data base. Even though extensive impact experiments were conducted e.g. in Sandia National Laboratories, Savannah River National Laboratory and by Rolls Royce plc, not all relevant factors were taken into account. Hence, BAM who is in charge of the mechanical evaluation of such packages within the approval procedure in Germany, incorporated systematic test series into a comprehensive research project aimed to develop numerical methods for a couple of damping materials. In a first step, displacement driven compression tests have been performed on confined, cubic specimens at five loading rates ranging from 0.02 mm/s to 3 m/s at temperatures between +90 deg. C and -40 deg. C. Materials include two different polyurethane foam types called FR3718 and FR3730 having densities of 280 kg/m{sup 3} and 488 kg/m{sup 3} from the product line-up of General Plastics Manufacturing Company. Their data was used to adapt an advanced plasticity model allowing for reliably simulating cellular materials under multi-axial compression states. Therefore, an automated parameter identification procedure had been established by combining an artificial neural network with local optimization techniques. Currently, the selected numerical material input values are validated and optimized by means of more complex loading configurations with the prospect of establishing methods applicable to impact limiters under severe accidental conditions. The reference data base is provided by experiments, where weights between 212 kg and 1200 kg have been dropped from heights between 1.25 m and 7 m on confined 10 cm cubic foam specimens. By presenting the deviations between experimental values and the corresponding output of finite element simulations, the potentials and restrictions of the resulting models are highlighted. Systematic compression tests on polyurethane foams had been performed at BAM test site within the framework of a research project on impact limiters for handling casks for radioactive waste. The experimental results had been used to adapt numerical models for simulating the behaviour of different foam types at different temperatures. The loading speed, however, turned out to have a major influence on their flow curves that can not be captured by simple strain-rate dependent multipliers. Especially for guided drop tests that come close to real accidental scenarios there is a significant gap between experimental and numerical results even when applying such advanced material models. Hence, the extensive data base is currently deployed for expanding the standard algorithms to include adequate dynamic hardening factors. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Iterative metal artifact reduction for x-ray computed tomography using unmatched projector/backprojector pairs

Purpose: Metal artifact reduction (MAR) is a major problem and a challenging issue in x-ray computed tomography (CT) examinations. Iterative reconstruction from sinograms unaffected by metals shows promising potential in detail recovery. This reconstruction has been the subject of much research in recent years. However, conventional iterative reconstruction methods easily introduce new artifacts around metal implants because of incomplete data reconstruction and inconsistencies in practical data acquisition. Hence, this work aims at developing a method to suppress newly introduced artifacts and improve the image quality around metal implants for the iterative MAR scheme. Methods: The proposed method consists of two steps based on the general iterative MAR framework. An uncorrected image is initially reconstructed, and the corresponding metal trace is obtained. The iterative reconstruction method is then used to reconstruct images from the unaffected sinogram. In the reconstruction step of this work, an iterative strategy utilizing unmatched projector/backprojector pairs is used. A ramp filter is introduced into the back-projection procedure to restrain the inconsistency components in low frequencies and generate more reliable images of the regions around metals. Furthermore, a constrained total variation (TV) minimization model is also incorporated to enhance efficiency. The proposed strategy is implemented based on an iterative FBP and an alternating direction minimization (ADM) scheme, respectively. The developed algorithms are referred to as “iFBP-TV” and “TV-FADM,” respectively. Two projection-completion-based MAR methods and three iterative MAR methods are performed simultaneously for comparison. Results: The proposed method performs reasonably on both simulation and real CT-scanned datasets. This approach could reduce streak metal artifacts effectively and avoid the mentioned effects in the vicinity of the metals. The improvements are evaluated by inspecting regions of interest and by comparing the root-mean-square errors, normalized mean absolute distance, and universal quality index metrics of the images. Both iFBP-TV and TV-FADM methods outperform other counterparts in all cases. Unlike the conventional iterative methods, the proposed strategy utilizing unmatched projector/backprojector pairs shows excellent performance in detail preservation and prevention of the introduction of new artifacts. Conclusions: Qualitative and quantitative evaluations of experimental results indicate that the developed method outperforms classical MAR algorithms in suppressing streak artifacts and preserving the edge structural information of the object. In particular, structures lying close to metals can be gradually recovered because of the reduction of artifacts caused by inconsistency effects.

60 APPLIED LIFE SCIENCES↗

Verification of severe accident management guideline (SAMG) entry condition for OPR1000 - 367

The current severe accident prevention and mitigation strategies for OPR 1000 have emergency operating procedures (EOPs) and severe accident management guidelines (SAMGs), respectively. The main objective of SAMG is to prevent a release of radioactive materials from releasing into environment and mitigate severe accident phenomena during severe accident. The current SAMG entry condition is met when the core exit temperature (CET) reaches 650 deg. C in OPR 1000. Peak cladding temperature (PCT), which represents core integrity more precisely than CET does, cannot be used since it is not measurable in the main control room (MCR). Current SAMG entry condition for every kind of accident scenarios is not reasonable, since entry condition is determined without considering operator action time. Therefore, SAMG entry condition need to be verified with consider operator action time. Thus, an analysis methodology for SAMG entry condition was developed to verify the SAMG entry condition. A severe accident DB were also developed in order to analyze the SAMG entry condition. The analysis results of DB show that available operator action time from the SAMG entrance to RV fail is shorter than the required time in most cases. As a result, the proper SAMG entry condition was suggested through the results of DB analysis. When the SAMG entry condition is changed from CET to suggested condition, the available action time is increased about 350 to 4300 sec. Also, the suggested entry condition was verified through the simulation which considered operation action time and reflecting the suggested entry condition. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

SU-E-T-639: Proton Dose Calculation for Irregular Motion Using a Sliding Interface

Purpose: While many techniques exist to evaluate dose to regularly moving lung targets, there are few available to calculate dose at tumor positions not present in the 4DCT. We have previously developed a method that extrapolates an existing dose to a new tumor location. In this abstract, we present a novel technique that accounts for relative anatomical shifts at the chest wall interface. We also utilize this procedure to simulate breathing motion functions on a cohort of eleven patients. Amplitudes exceeding the original range of motion were used to evaluate coverage using several aperture and smearing beam settings. Methods: The water-equivalent depth (WED) technique requires an initial dose and CT image at the corresponding tumor position. Each dose volume was converted from its Cartesian geometry into a beam-specific radiological depth space. The sliding chest wall interface was determined by converting the lung contour into this same space. Any dose proximal to the initial boundary of the warped lung contour was held fixed, while the remaining distal dose was moved in the direction of motion along the interface. Results: V95 coverage was computed for each patient using the updated algorithm. Incorporation of the sliding motion yielded large dose differences, with gamma pass rates as low as 69.7% (3mm, 3%) and V95 coverage differences up to 2.0%. Clinical coverage was maintained for most patients with 5 mm excess simulated breathing motion, and up to 10 mm of excess motion was tolerated for a subset of patients and beam settings. Conclusion: We have established a method to determine the maximum allowable excess breathing motion for a given plan on a patient-by-patient basis. By integrating a sliding chest wall interface into our dose calculation technique, we have analyzed the robustness of breathing patterns that differ during treatment from at the time of 4DCT acquisition.

61 RADIATION PROTECTION AND DOSIMETRY↗