At least 721 records · Page 40

A MEASUREMENT OF THE ADIABATIC COOLING INDEX FOR INTERSTELLAR HELIUM PICKUP IONS IN THE INNER HELIOSPHERE

Interstellar neutral gas enters the inner heliosphere where it is ionized and becomes the pickup ion population of the solar wind. It is often assumed that this population will subsequently cool adiabatically, like an expanding ideal gas due, to the divergent flow of the solar wind. Here, we report the first independent measure of the effective adiabatic cooling index in the inner heliosphere from SOHO CELIAS measurements of singly charged helium taken during times of perpendicular interplanetary magnetic field. We use a simple adiabatic transport model of interstellar pickup helium ions, valid for the upwind region of the inner heliosphere. The time averaged velocity spectrum of helium pickup ions measured by CELIAS/CTOF is fit to this model with a single free parameter which indicates an effective cooling rate with a power-law index of gamma = 1.35 +- 0.2. While this average is consistent with the 'ideal-gas' assumption of gamma = 1.5, the analysis indicates that such an assumption will not apply in general, and that due to observational constraints further measurements are necessary to constrain the cooling process. Implications are discussed for understanding the transport processes in the inner heliosphere and improving this measurement technique.

79 ASTRONOMY AND ASTROPHYSICS↗

Longitudinal magnetohydrodynamics oscillations in dissipative, cooling coronal loops

This paper investigates the effect of cooling on standing slow magnetosonic waves in coronal magnetic loops. The damping mechanism taken into account is thermal conduction that is a viable candidate for dissipation of slow magnetosonic waves in coronal loops. In contrast to earlier studies, here we assume that the characteristic damping time due to thermal conduction is not small, but arbitrary, and can be of the order of the oscillation period, i.e., a temporally varying plasma is considered. The approximation of low-beta plasma enables us to neglect the magnetic field perturbation when studying longitudinal waves and consider, instead, a one-dimensional motion that allows a reliable first insight into the problem. The background plasma temperature is assumed to be decaying exponentially with time, with the characteristic cooling timescale much larger than the oscillation period. This assumption enables us to use the WKB method to study the evolution of the oscillation amplitude analytically. Using this method we obtain the equation governing the oscillation amplitude. The analytical expressions determining the wave properties are evaluated numerically to investigate the evolution of the oscillation frequency and amplitude with time. The results show that the oscillation period increases with time due to the effect of plasma cooling. The plasma cooling also amplifies the amplitude of oscillations in relatively cool coronal loops, whereas, for very hot coronal loop oscillations the damping rate is enhanced by the cooling. We find that the critical point for which the amplification becomes dominant over the damping is in the region of 4 MK. These theoretical results may serve as impetus for developing the tools of solar magneto-seismology in dynamic plasmas.

79 ASTRONOMY AND ASTROPHYSICS↗

Advances in Integral and Separate Effects Experiments for Water Cooled Small Modular Reactors

This paper focuses on the progress being made in water-cooled small modular reactor (SMR) advanced integral effects and separate effects experiments for reactor licensing. SMRs, considered modular in design, are mostly factory-built and then shipped to the reactor site. Of the several types of SMR designs available, water-cooled SMRs are likely to receive regulatory approval faster than others, as most of the technologies involved (e.g., the fuel and coolant technologies) are matured. However, the unique safety systems of SMRs, which depend on specific SMR design features, require integral and separate effects experiments to achieve reactor licensing. Thus, of the many SMR designs being proposed, only a few have successfully undergone licensing and reached the final development and demonstration stage. Many nuclear vendors and newcomer companies are investing millions of dollars to develop integral and separate effects testing facilities for preparing final safety analysis reports to include in licensing applications. Development and analysis of these experimental facilities is costly and takes about four to five years. The unique challenges involved can be reduced when stakeholders synergistically apply lessons learned, knowing the critical role played by advancements in experiments that support the licensing of SMR safety systems. Identification of knowledge/research gaps with the phenomena identification and ranking table (PIRT) and designing experimental facilities focusing on the phenomena of interest (POI) and figures of merit (FOMs) are pivotal to select the critical path to successful design demonstration and licensing application.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Helical muon beam cooling channel engineering design

The Helical Cooling Channel (HCC) achieves effective ionization cooling of the six-dimensional (6d) phase space of a muon beam by means of a series of 21st century inventions. In the HCC, hydrogen-pressurized RF cavities enable high RF gradients in strong external magnetic fields. The theory of the HCC, which requires a magnetic field with solenoid, helical dipole, and helical quadrupole components, demonstrates that dispersion in the gaseous hydrogen energy absorber provides effective emittance exchange to enable longitudinal ionization cooling. The 10-year development of a practical implementation of a muon-beam cooling device has involved a series of technical innovations and experiments that imply that an HCC of less than 300 m length can cool the 6d emittance of a muon beam by six orders of magnitude. We describe the design and construction plans for a prototype HCC module based on oxygen-doped hydrogen-pressurized RF cavities that are loaded with dielectric, fed by magnetrons, and operate in a superconducting helical solenoid magnet. The first phase of this project saw the development of a conceptual design for the integration of 805 MHz RF cavities into a 10 T Nb 3 Sn-based HS test section. Two very novel ideas are required to realize the design. The first idea is the use of dielectric inserts in the RF cavities to make them smaller for a given frequency so that the cavities and associated plumbing easily fit inside the magnet cryostat. Calculations indicate that heat loads will be tolerable, while RF breakdown of the dielectric inserts will be suppressed by the pressurized hydrogen gas. The second new idea is the use of a multi-layer Nb 3 Sn helical solenoid. The technology demonstrations for the two aforementioned key components of a 10T, 805 MHz HCC were begun in this project. The work load in the Fermilab Technical Division made it difficult to test a multi-layer Nb 3 Sn solenoid as originally planned. Instead, a complementary project was approved by the DOE Technical Topic Manager to develop magnets for the Mu2e experiment that fit well into the Fermilab Technical Division availability. The difference between the MCC helical solenoid and the Mu2e bent solenoid described in Appendix I is that the helical solenoid is made of coils that are in parallel planes with offset centers, while the coils in the bent solenoid follow the central particle trajectory and look much like a “slinky” toy. The muon-beam cooling-channel technologies developed in this project will enable a muon collider, the next step toward the energy frontier, Higgs/neutrino/Z-factories, and rare muon decay experiments. Commercial uses of the beams made possible by the cooling techniques developed in this project include scanning for nuclear contraband, studies of material properties with spin resonance techniques, and muon-catalyzed fusion.

43 PARTICLE ACCELERATORS↗

Muon Beam Helical Cooling Channel Design

The Helical Cooling Channel (HCC) achieves effective ionization cooling of the six-dimensional (6d) phase space of a muon beam by means of a series of 21st century inventions. In the HCC, hydrogen-pressurized RF cavities enable high RF gradients in strong external magnetic fields. The theory of the HCC, which requires a magnetic field with solenoid, helical dipole, and helical quadrupole components, demonstrates that dispersion in the gaseous hydrogen energy absorber provides effective emittance exchange to enable longitudinal ionization cooling. The 10-year development of a practical implementation of a muon-beam cooling device has involved a series of technical innovations and experiments that imply that an HCC of less than 300 m length can cool the 6d emittance of a muon beam by six orders of magnitude. We describe the design and construction plans for a prototype HCC module based on oxygen-doped hydrogen-pressurized RF cavities that are loaded with dielectric, fed by magnetrons, and operate in a superconducting helical solenoid magnet.

Johnson, Rolland↗

LES-Based Analysis of Film Cooling in a High-Pressure Turbine Rotor Including Effects of Purge and Tip Flow

Accurate modeling of coolant airflows, which form protective films over turbine blades, is essential for designing fuel-efficient and environmentally sustainable gas turbine engines. Excessive coolant reduces thermal efficiency, while insufficient coolant leads to blade overheating and causes damage. Therefore, precise prediction of flow field interactions with cooling air is critical for optimizing turbine performance. This study numerically investigates the cooling effectiveness of purge and film cooling flows within a high-pressure turbine (HPT) rotor using Large Eddy Simulation (LES). The study utilizes NASA Glenn Research Center’s Glenn-HT solver. The simulation models ethe conditions of the Penn State University START rotating rig. A high-fidelity structured mesh comprising up to 800 million cells is employed to resolve high-Reynolds number flow (Re ≈ 350,000) and to capture intricate secondary flow structures, including tip leakage and purge-induced vortices. Film cooling effectiveness computations are highly sensitive to boundary conditions at the cooling holes and to grid resolution. Even with well-resolved grids and included plena, strong mixing challenges traditional eddy viscosity models. To address this, a simplified configuration is simulated: a truncated row of shaped holes on the suction side near the leading edge and a row on the pressure side, both fed from internal plena while the purge slot and tip clearance are also modeled. Two isothermal LES cases are conducted at two distinct wall temperatures, which yield the adiabatic wall temperature and the heat transfer coefficient. The definition and means of computation of the effectiveness is discussed in this paper. The simulations reveal detailed three-dimensional unsteady flow features, including coherent vortical structures and secondary flows originating from the purge cavity. Film cooling effectiveness and Nusselt number distributions are presented for both the blade surface and tip, highlighting regions of elevated heat transfer and complex thermal behavior. These findings underscore the importance of high-resolution LES and realistic boundary conditions in capturing the dynamics of purge and film cooling, offering valuable insights for improving turbine blade design and thermal management strategies.

Secondary Flows↗

Comparison of effectiveness of convection-, transpiration-, and film-cooling methods with air as coolant

Various parts of aircraft propulsion engines that are in contact with hot gases often require cooling. Transpiration and film cooling, new methods that supposedly utilize cooling air more effectively than conventional convection cooling, have already been proposed. This report presents material necessary for a comparison of the cooling requirements of these three methods. Correlations that are regarded by the authors as the most reliable today are employed in evaluating each of the cooling processes. Calculations for the special case in which the gas velocity is constant along the cooled wall (flat plate) are presented. The calculations reveal that a comparison of the three cooling processes can be made on quite a general basis. The superiority of transpiration cooling is clearly shown for both laminar and turbulent flow. This superiority is reduced when the effects of radiation are included; for gas-turbine blades, however, there is evidence indicating that radiation may be neglected.

Eckert, E R G↗

Cooling of Gas Turbines I - Effects of Addition of Fins to Blade Tips and Rotor, Admission of Cooling Air Through Part of Nozzles, and Change in Thermal Conductivity of Turbine Components

An analysis was developed for calculating the radial temperature distribution in a gas turbine with only the temperatures of the gas and the cooling air and the surface heat-transfer coefficient known. This analysis was applied to determine the temperatures of a complete wheel of a conventional single-stage impulse exhaust-gas turbine. The temperatures were first calculated for the case of the turbine operating at design conditions of speed, gas flow, etc. and with only the customary cooling arising from exposure of the outer blade flange and one face of the rotor to the air. Calculations were next made for the case of fins applied to the outer blade flange and the rotor. Finally the effects of using part of the nozzles (from 0 to 40 percent) for supplying cooling air and the effects of varying the metal thermal conductivity from 12 to 260 Btu per hour per foot per degree Farenheit on the wheel temperatures were determined. The gas temperatures at the nozzle box used in the calculations ranged from 1600F to 2000F. The results showed that if more than a few hundred degrees of cooling of turbine blades are required other means than indirect cooling with fins on the rotor and outer blade flange would be necessary. The amount of cooling indicated for the type of finning used could produce some improvement in efficiency and a large increase in durability of the wheel. The results also showed that if a large difference is to exist between the effective temperature of the exhaust gas and that of the blade material, as must be the case with present turbine materials and the high exhaust-gas temperatures desired (2000F and above), two alternatives are suggested: (a) If metal with a thermal conductivity comparable with copper is used, then the blade temperature can be reduced by strong cooling at both the blade tip and root. The center of the blade will be less than 2000F hotter than the ends; (b) With low conductivity materials some method of direct cooling other than partial admission of cooling air is essential. From this study, it can be deduced that indirect cooling of turbine blades will not make possible large increases in gas temperature.

Brown, Byron↗

Giant zero field cooled spontaneous exchange bias effect in phase separated La{sub 1.5}Sr{sub 0.5}CoMnO{sub 6}

We report a giant zero field cooled exchange bias (ZEB) effect (∼0.65 T) in La{sub 1.5}Sr{sub 0.5}CoMnO{sub 6} sample. Magnetic study has revealed a reentrant spin glass ∼90 K, phase separation to spin glass and ferromagnetic phases below 50 K and canted antiferromagnetic transition ∼10 K. A small conventional exchange bias (CEB) is established with the advent of spontaneous phase separation down to 10 K. Giant ZEB and enhanced CEB effects are found only below 10 K and are attributed to the large unidirectional anisotropy at the interface of isothermally field induced ferromagnetic phase and canted antiferromagnetic background.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Temperature Mapping of Air Film-Cooled Thermal Barrier Coated Surfaces Using Phosphor Thermometry

While the effects of thermal barrier coating (TBC) thermal protection and air film cooling effectiveness for jet engine components are usually studied separately, their contributions to combined cooling effectiveness are interdependent and are not simply additive. Therefore, combined cooling effectiveness must be measured to achieve an optimum balance between TBC thermal protection and air film cooling. Phosphor thermometry offers several advantages for mapping temperatures of air film cooled surfaces. While infrared thermography has been typically applied to study air film cooling effectiveness, temperature accuracy depends on knowing surface emissivity (which may change) and correcting for effects of reflected radiation. Because decay time-based full-field phosphor thermometry is relatively immune to these effects, it can be applied advantageously to temperature mapping of air film-cooled TBC-coated surfaces. In this presentation, an overview will be given of efforts at NASA Glenn Research Center to perform temperature mapping of air film-cooled TBC-coated surfaces in a burner rig test environment. The effects of thermal background radiation and flame chemiluminescence on the measurements are investigated, and the strengths and limitations of this method for studying air film cooling effectiveness are discussed.

air film cooling↗

Cooled miniature pressure transducers effective at high temperatures

Miniature pressure transducers in compact water-cooled mounts are placed in hotter and more confined environments than previously possible. It quantitatively measures high frequency total pressure fluctuations resulting from rotating stall in an axial flow engine compressor.

Armentrout, E. C.↗

Stoichiometric gas turbines - Development problems.

Detroit Diesel Allison has been active in demonstrating the feasibility of stoichiometric gas turbine engines for many years. Results of this program are presented with emphasis placed on areas requiring additional development work. Cooling air usage, the effect of cooling air on turbine efficiency, fabrication (materials) methods, and control (instrumentation) techniques are the areas discussed and illustrated. Lamilloy, a pseudo-transpiring material developed by Allison, is discussed in detail.

Helms, H. E.↗

Effect of occupant behavior on peak cooling and dehumidification loads in typical and high-efficiency homes

Residential building codes and voluntary labeling programs are continually increasing the energy efficiency requirements of residential buildings. Improving a building's thermal enclosure, installing the ductwork in conditioned space, and improving the building's airtightness results in significant reductions in externally-driven sensible and latent cooling loads. As a building's efficiency is improved, occupant-related internal gains become a larger portion of the building sensible and latent loads. Additionally, internal gains are highly uncertain compared to other load components. In this study, we use a stochastic approach to simulate occupant-related internal gains and compare the internal gains to other sensible and latent heat sources in four house efficiency levels in 10 U.S. climates using whole-building energy simulation software. We compare the expected range in occupant-related internal gains to other building characteristics such as cooling set point, air infiltration rate, and mechanical ventilation rate. We show that in high-efficiency homes, sensible internal gains vary from less than 10% to greater than 40% of the building sensible load under peak total cooling conditions depending on climate and internal gain profile. Likewise, latent internal gains vary from less than 10% to more than 60% of the building latent load under peak total cooling and peak dehumidification conditions depending on climate and internal gain profile.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Effects of composition and canister centerline cooling on microstructure, phase distribution, and chemical durability of dehalogenated iron phosphate waste forms

This paper discusses the effects of composition and canister centerline cooling (CCC) on the microstructures, phase distribution, and chemical durability of dehalogenated iron phosphate waste forms starting from chloride-based salt simulants including KCl (Simple-1), NdCl3 (Simple-2), SrCl2 (Simple-3), LaCl3 (Simple-4), LiCl (Simple-5), CsCl (Simple-6), as well as a complex simulant containing LiCl, KCl, NaCl, CsI, SrCl2, CeCl3, and NdCl3 called ERV2. The simulants represent salt constituents present in salt wastes from electrorefiners used for electrochemical reprocessing. These salts are reacted with ammonium dihydrogen phosphate (ADP) resulting in a NH4Cl (dechlorination) byproduct that is captured and phosphate product containing oxides of the salt cations. This product is further stabilized using Fe2O3 through vitrification at higher temperatures. The results presented herein describe the properties of CCC-treated materials following dechlorination and vitrification including phase identification and quantification, elemental distributions, and chemical durabilities. The chemical durability in the CCC-cooled samples are lower durability than quenched materials for the ERV2 samples. The phases formed upon CCC cooling are very complex compositionally and microstructurally.

iron phosphate glass, iron phosphate waste forms, ↗

Lab Evaluation of Downward Capacity of Radiant Ceiling Panel Systems

This project investigated the cooling delivery effectiveness of radiant ceiling panels as a function of attic insulation level using multiple laboratory testing and analytical methodologies. Delivery effectiveness is the heating or cooling energy delivered to a conditioned space divided by the total heating or cooling energy added or removed by the space conditioning system. The lower the losses of the heating or cooling delivery method, the higher the delivery effectiveness. For ducted systems, delivery effectiveness is reduced by both air leakage and thermal losses (especially if the ducts are installed in attics), while the delivery effectiveness of a radiant system supplied by hot and cold water is only reduced by thermal losses, which can be mitigated by sufficient insulation above, or at the "back" of the panel. Being installed at or below the ceiling plane, sufficient back insulation should be provided by default in the form of the attic insulation above the radiant ceiling panels. Site-built radiant ceiling panels were evaluated at Frontier Energy’s Building Science Research Laboratory (BSRL) in a uniquely designed environmental test chamber with independently controllable indoor and attic spaces and a height-adjustable ceiling.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Two dimensional cold air cascade study of a film cooled turbine stator blade. 2: Experimental results of full film cooling tests

The effect of full film cooling on the performance of a turbine stator blade was studied in a two-dimensional cascade. The blade contained 12 rows of coolant holes, 6 rows on the suction surface and 6 on the pressure surface. Separate tests were first made with coolant ejection from each of the 12 rows. Then successive tests were made with various combinations of coolant rows open, including full film cooling. The principal results are presented in terms of primary-air efficiency as a function of coolant fraction. In addition, the efficiency results of the multirow tests are compared with the multi-row efficiency predicted by adding the single-row results.

Prust, H. W., Jr.↗