Search NASA⌕ Search

SEARCH · Search NASA

Results for “detection system”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 721 records · Page 40

Trace double-component gas sensor in photoacoustic spectroscopy based on frequency division multiplexing

In this paper, we demonstrated a trace double-component gas detection system based on frequency division multiplexing using two-way distributed feedback laser diode (DFB-LD) as the excitation laser source. In the frequency response range of photoacoustic spectroscopy (PAS) cell, this detection system could detect the second harmonics of different frequencies f{sub 0} and f{sub 1}, which were excited by the gas absorption using the two wavelengths of DFB-LD at modulation frequencies f{sub 0}/2 and f{sub 1}/2. Unlike previous double-component gas sensor, these two DFB-LDs connected into the both ends of PAS cell without optical fiber coupler could effectively improve the excited light intensity and simplify the system structure. This feature allowed the trace detection of double-component gas of mixed-methane (CH{sub 4}) and water (H{sub 2}O) vapor with a low detection limits 11.055 ppm and 885 ppb, respectively. Additionally, the linear responses to the gas concentration were achieved 0.9986 and 0.9997, and it exhibited potentially as an effective detection system for complex gas component.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Review of Intrusion Detection Methods and Tools for Distributed Energy Resources

Recent trends in the growth of distributed energy resources (DER) in the electric grid and newfound malware frameworks that target internet of things (IoT) devices is driving an urgent need for more reliable and effective methods for intrusion detection and prevention. Cybersecurity intrusion detection systems (IDSs) are responsible for detecting threats by monitoring and analyzing network data, which can originate either from networking equipment or end-devices. Creating intrusion detection systems for PV/DER networks is a challenging undertaking because of the diversity of the attack types and intermittency and variability in the data. Distinguishing malicious events from other sources of anomalies or system faults is particularly difficult. New approaches are needed that not only sense anomalies in the power system but also determine causational factors for the detected events. In this report, a range of IDS approaches were summarized along with their pros and cons. Using the review of IDS approaches and subsequent gap analysis for application to DER systems, a preliminary hybrid IDS approach to protect PV/DER communications is formed in the conclusion of this report to inform ongoing and future research regarding the cybersecurity and resilience enhancement of DER systems.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Independent malware detection architecture

A system and method (referred to as the system) detect malware by training a rule-based model, a functional based model, and a deep learning-based model from a memory snapshot of a malware free operating state of a monitored device. The system extracts a feature set from a second memory snapshot captured from an operating state of the monitored device and processes the feature set by the rule-based model, the functional-based model, and the deep learning-based model. The system identifies identifying instances of malware on the monitored device without processing data identifying an operating system of the monitored device, data associated with a prior identification of the malware, data identifying a source of the malware, data identifying a location of the malware on the monitored device, or any operating system specific data contained within the monitored device.

Smith, Jared M.↗

Sensing system for detection and control of deposition on pendant tubes in recovery and power boilers

A system for detection and control of deposition on pendant tubes in recovery and power boilers includes one or more deposit monitoring sensors operating in infrared regions of about 4 or 8.7 microns and directly producing images of the interior of the boiler, or producing feeding signals to a data processing system for information to enable a distributed control system by which the boilers are operated to operate said boilers more efficiently. The data processing system includes an image pre-processing circuit in which a 2-D image formed by the video data input is captured, and includes a low pass filter for performing noise filtering of said video input. It also includes an image compensation system for array compensation to correct for pixel variation and dead cells, etc., and for correcting geometric distortion. An image segmentation module receives a cleaned image from the image pre-processing circuit for separating the image of the recovery boiler interior into background, pendant tubes, and deposition. It also accomplishes thresholding/clustering on gray scale/texture and makes morphological transforms to smooth regions, and identifies regions by connected components. An image-understanding unit receives a segmented image sent from the image segmentation module and matches derived regions to a 3-D model of said boiler. It derives a 3-D structure the deposition on pendant tubes in the boiler and provides the information about deposits to the plant distributed control system for more efficient operation of the plant pendant tube cleaning and operating systems.

47 OTHER INSTRUMENTATION↗

A PHOTOMETRIC SYSTEM FOR DETECTION OF WATER AND METHANE ICES ON KUIPER BELT OBJECTS

We present a new near-infrared photometric system for detection of water ice and methane ice in the solar system. The system consists of two medium-band filters in the K-band region of the near-infrared, which are sensitive to water ice and methane ice, plus continuum observations in the J band and Y band. The primary purpose of this system is to distinguish between three basic types of Kuiper Belt Objects (KBOs)-those rich in water ice, those rich in methane ice, and those with little absorbance. In this work, we present proof-of-concept observations of 51 KBOs using our filter system, 21 of which have never been observed in the near-infrared spectroscopically. We show that our custom photometric system is consistent with previous spectroscopic observations while reducing telescope observing time by a factor of {approx}3. We use our filters to identify Haumea collisional family members, which are thought to be collisional remnants of a much larger body and are characterized by large fractions of water ice on their surfaces. We add 2009 YE{sub 7} to the Haumea collisional family based on our water ice band observations (J - H{sub 2}O = -1.03 {+-} 0.27) which indicate a high amount of water ice absorption, our calculated proper orbital elements, and the neutral optical colors we measured, V - R = 0.38 {+-} 0.04, which are all consistent with the rest of the Haumea family. We identify several objects dynamically similar to Haumea as being distinct from the Haumea family as they do not have water ice on their surfaces. In addition, we find that only the largest KBOs have methane ice, and Haumea itself has significantly less water ice absorption than the smaller Haumea family members. We find no evidence for other families in the Kuiper Belt.

79 ASTRONOMY AND ASTROPHYSICS↗

A stopping theoretic approach to minimal time detection of system parameter change

The problem of minimal time detection of abrupt parameter changes in linear stochastic systems considered. The problem is posed as an optimal stopping problem for the detection in change of the induced probability measure. Under the assumption of a prior distribution for the time of change (or disruption) a stopping rule is given which minimizes the average detection delay when there is knowledge of the new measure after the change. When the new induced measure is unknown, a stopping rule is given, based only on the noisy observations and is shown to be better than the a priori knowlege of the disruption time.

Mazumdar, Ravi R.↗

Improved Fission Neutron Data Base for Active Interrogation of Actinides

This project will develop an innovative neutron detection system for active interrogation measurements. Many active interrogation methods to detect fissionable material are based on the detection of neutrons from fission induced by fast neutrons or high-energy gamma rays. The energy spectrum of the fission neutrons provides data to identify the fissionable isotopes and materials such as shielding between the fissionable material and the detector. The proposed path for the project is as follows. First, the team will develop new neutron detection systems and algorithms by Monte Carlo simulations and bench-top experiments. Next, they will characterize and calibrate detection systems both with monoenergetic and white neutron sources. Finally, high-fidelity measurements of neutron emission from fissions induced by fast neutrons will be performed. Several existing fission chambers containing U-235, Pu-239, U-238, or Th-232 will be used to measure the neutron-induced fission neutron emission spectra. The challenge for making confident measurements is the detection of neutrons in the energy ranges of 0.01 – 1 MeV and above 8 MeV, regions where the basic data on the neutron energy spectrum emitted from fission is least well known. In addition, improvements in the specificity of neutron detectors are required throughout the complete energy range: they must be able to clearly distinguish neutrons from other radiations, in particular gamma rays and cosmic rays. The team believes that all of these challenges can be addressed successfully with emerging technologies under development by this collaboration. In particular, the collaboration will address the area of fission neutron emission spectra for isotopes of interest in the advanced fuel cycle initiative (AFCI).

Pozzi, Sara A.↗

Methods and systems for detection of radionuclides

Disclosed are materials and systems useful in determining the existence of radionuclides in an aqueous sample. The materials provide the dual function of both extraction and scintillation to the systems. The systems can be both portable and simple to use, and as such can beneficially be utilized to determine presence and optionally concentration of radionuclide contamination in an aqueous sample at any desired location and according to a relatively simple process without the necessity of complicated sample handling techniques. The disclosed systems include a one-step process, providing simultaneous extraction and detection capability, and a two-step process, providing a first extraction step that can be carried out in a remote field location, followed by a second detection step that can be carried out in a different location.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Attention focusing and anomaly detection in systems monitoring

Any attempt to introduce automation into the monitoring of complex physical systems must start from a robust anomaly detection capability. This task is far from straightforward, for a single definition of what constitutes an anomaly is difficult to come by. In addition, to make the monitoring process efficient, and to avoid the potential for information overload on human operators, attention focusing must also be addressed. When an anomaly occurs, more often than not several sensors are affected, and the partially redundant information they provide can be confusing, particularly in a crisis situation where a response is needed quickly. The focus of this paper is a new technique for attention focusing. The technique involves reasoning about the distance between two frequency distributions, and is used to detect both anomalous system parameters and 'broken' causal dependencies. These two forms of information together isolate the locus of anomalous behavior in the system being monitored.

Doyle, Richard J.↗

Microwave System for Detecting Ice on Aircraft

A microwave-based system has been developed as a means of detecting ice on aircraft surfaces, with enough sensitivity to provide a warning before the ice accretes to a dangerous thickness. The system can measure the thickness of ice from a few mils (1 mil = 0.0254 mm) to about 1/4 in. (.6 mm) and can distinguish among (1) ice, (2) water (or deicing fluid), and (3) a mixture of ice and water (or deicing fluid). Sensors have been ruggedized to withstand the rain erosion environment.

Joseph, Philip J.↗

Collection of Infrasonic Sound From Sources of Military Importance

Extreme Endeavors is collaborating with NASA Langley Research Center (LaRC) in the development, testing and analysis of infrasonic detection system under a Space Act Agreement. Acoustic studies of atmospheric events like convective storms, shear-induced turbulence, acoustic gravity waves, microbursts, hurricanes, and clear air turbulence (CAT) over the past thirty years have established that these events are strong emitters of infrasound. Recently NASA Langley Research Center has designed and developed a portable infrasonic detection system which can be used to make useful infrasound measurements at locations where it was not possible previously, such as a mountain crag, inside a cave or on the battlefield. The system comprises an electret condenser microphone, having a 3-inch membrane diameter, and a small, compact windscreen. Extreme Endeavors will present the findings from field testing using this portable infrasonic detection system. Field testing of the infrasonic detection system was partly funded by Greer Industries and support provided by the West Virginia Division of Natural Resources. The findings from this work illustrate the ability to detect structure and other information about the contents inside the caves. The presentation will describe methodology for utilizing infrasonic to locate and portray underground facilities.

Masterman, Michael↗

A system to detect cerebral aneurysms in multimodality angiographic data sets

Purpose: The early detection of cerebral aneurysms plays a major role in preventing subarachnoid hemorrhage. The authors present a system to automatically detect cerebral aneurysms in multimodal 3D angiographic data sets. The authors’ system is parametrizable for contrast-enhanced magnetic resonance angiography (CE-MRA), time-of-flight magnetic resonance angiography (TOF-MRA), and computed tomography angiography (CTA). Methods: Initial volumes of interest are found by applying a multiscale sphere-enhancing filter. Several features are combined in a linear discriminant function (LDF) to distinguish between true aneurysms and false positives. The features include shape information, spatial information, and probability information. The LDF can either be parametrized by domain experts or automatically by training. Vessel segmentation is avoided as it could heavily influence the detection algorithm. Results: The authors tested their method with 151 clinical angiographic data sets containing 112 aneurysms. The authors reach a sensitivity of 95% with CE-MRA data sets at an average false positive rate per data set (FP{sub DS}) of 8.2. For TOF-MRA, we achieve 95% sensitivity at 11.3 FP{sub DS}. For CTA, we reach a sensitivity of 95% at 22.8 FP{sub DS}. For all modalities, the expert parametrization led to similar or better results than the trained parametrization eliminating the need for training. 93% of aneurysms that were smaller than 5 mm were found. The authors also showed that their algorithm is capable of detecting aneurysms that were previously overlooked by radiologists. Conclusions: The authors present an automatic system to detect cerebral aneurysms in multimodal angiographic data sets. The system proved as a suitable computer-aided detection tool to help radiologists find cerebral aneurysms.

60 APPLIED LIFE SCIENCES↗

Methods and systems for detection of man-in-the-middle attacks for SCADA communication networks and applications of same

A system for detecting MITM for SCADA communication networks includes secure substation-substation communication links for providing secure and reliable paths to exchange OT data between substations for OT data consistency check; a SIB in each substation for sampling CT and PT measurements to calculate voltage magnitude and phase angle thereof; a S&C server in each substation coupled to the SIB for receiving the voltage magnitude and phase angle from the SIB and obtaining a packet carrying active power flow in transmission lines between two substations and a time stamp; an IDS server placed in a SCADA center for collecting the packet of each substation sent by the S&C server; analyzing the received packet from every adjacent substation; inspecting the payload of the received packet; and triggering an intrusion alarm to a SCADA operator when the power flow is not the same as the payload of the packets.

McCann, Roy A.↗

Conceptual design of a hybrid neutron-gamma detector for study of β-delayed neutrons at the RIB facility of RIKEN

Here, the conceptual design of the BRIKEN neutron detector at the radioactive ion beam factory (RIBF) of the RIKEN Nishina Center is reported. The BRIKEN setup is a complex system aimed at detecting heavy-ion implants, β particles, γ rays and β-delayed neutrons. The whole setup includes the Advanced Implantation Detection Array (AIDA), two HPGe Clover detectors and up to 166 3 He-filled counters embedded in a high-density polyethylene moderator. The design is quite complex due to the large number and different types of 3 He-tubes involved and the additional constraints introduced by the ancillary detectors for charged particles and γ rays. This article reports on a novel methodology developed for the conceptual design and optimisation of the 3 He-counter array, aiming for the best possible performance in terms of neutron detection. The algorithm is based on a geometric representation of two selected detector parameters of merit, namely, the average neutron detection efficiency and the efficiency flatness as a function of a reduced number of geometric variables. The response of the neutron detector is obtained from a systematic Monte Carlo simulation implemented in GEANT4. The robustness of the algorithm allowed us to design a versatile detection system, which operated in hybrid mode includes the full neutron counter and two clover detectors for high-precision gamma spectroscopy. In addition, the system can be reconfigured into a compact mode by removing the clover detectors and re-arranging the 3 He tubes in order to maximize the neutron detection performance. Both operation modes shows a rather flat and high average efficiency. In summary, we have designed a system which shows an average efficiency for hybrid mode ( 3 He tubes + clovers) of 68.6% and 64% for neutron energies up to 1 and 5 MeV, respectively. For compact mode (only 3 He tubes), the average efficiency is 75.7% and 71% for neutron energies up to 1 and 5 MeV, respectively. The performance of the BRIKEN detection system has been also quantified by means of Monte Carlo simulations with different neutron energy distributions.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Discrimination Report: A Multisensor system for detection andcharacterization of UXO, ESTCP Project MM-0437,

The Berkeley UXO Discriminator (BUD) is an optimally designed active electromagnetic system that not only detects but also characterizes UXO. The performance of the system is governed by a target size-depth curve. BUD was designed to detect UXO in the 20 mm to 155 mm size range for depths between 0 and 1.5 m, and to characterize them in a depth range from 0 to 1.1 m. The system incorporates three orthogonal transmitters and eight pairs of differenced receivers. Eight receiver coils are placed horizontally along the two diagonals of the upper and lower planes of the two horizontal transmitter loops. These receiver coil pairs are located on symmetry lines through the center of the system and each pair sees identical fields during the on-time of the pulse in all of the transmitter coils. They are wired in opposition to produce zero output during the on-time of the pulses in three orthogonal transmitters. Moreover, this configuration dramatically reduces noise in the measurements by canceling the background electromagnetic fields (these fields are uniform over the scale of the receiver array and are consequently nulled by the differencing operation), and by canceling the noise contributed by the tilt motion of the receivers in the Earth's magnetic field, and greatly enhances receiver sensitivity to the gradients of the target response. BUD is mounted on a small cart to assure system mobility. System positioning is provided by a Real Time Kinematic (RTK) GPS receiver. The system has two modes of operation: (1) the search mode, in which BUD moves along a profile and exclusively detects targets in its vicinity providing target depth and horizontal location, and (2) the discrimination mode, in which BUD is stationary above a target, and determines three discriminating polarizability responses together with the object location and orientation from a single position of the system. The detection performance of the system is governed by a size-depth curve shown in Figure 2. This curve was calculated for BUD assuming that the receiver plane is 0.2 m above the ground. Figure 2 shows that, for example, BUD can detect an object with 0.1 m diameter down to the depth of 0.9 m with a depth uncertainty of 10%. Any objects buried at a depth of more than 1.3 m will have a low probability of detection. The discrimination performance of the system is governed by a size-depth curve shown in Figure 3. Again, this curve was calculated for BUD assuming that the receiver plane is 0.2 m above the ground. Figure 3 shows that, for example, BUD can determine the polarizability of an object with 0.1 m diameter down to the depth of 0.63 m with polarizability uncertainty of 10%. Any objects buried at the depth more than 0.9 m will have a low discrimination probability. Object orientation estimates and equivalent dipole polarizability estimates used for large and shallow UXO/scrap discrimination are more problematic as they are affected by higher order (non-dipole) terms induced in objects due to source field gradients along the length of the objects. For example, a vertical 0.4 m object directly below the system needs to be about 0.90 m deep for perturbations due to gradients along the length of the object to be of the order of 20% of the uniform field object response. Similarly, vertical objects 0.5 m, and 0.6 m long need to be 1.15 m, and 1.42 m, respectively, below the system. For horizontal objects the effect of gradients across the object diameter are much smaller. For example, 155 mm and 105 mm projectiles need to be only 0.30 m, and 0.19 m, respectively, below the system. A polarizability index (in cm{sup 3}), which is an average value of the product of time (in seconds) and polarizability rate (in m{sup 3}/s) over the 34 sample times logarithmically spaced from 143 to 1300 {micro}s, and three polarizabilities, can be calculated for any object. We used this polarizability index to decide when the object is in a uniform source field. Objects with the polarizability index smaller than 600 cm{sup 3} and deeper than 1.8 m below BUD, or smaller than 200 cm{sup 3} and deeper than 1.35 m, or smaller than 80 cm{sup 3} and deeper than 0.90 m, or smaller than 9 cm{sup 3} and deeper than 0.20 m below BUD are sufficiently deep that the effects of vertical source field gradients should be less than 15%. All other objects are considered large and shallow objects. At the moment, interpretation software is available for a single object only. In case of multiple objects the software indicates the possible presence of metallic objects but is unable to provide characteristics of each individual object.

54 ENVIRONMENTAL SCIENCES↗

EVALUATING THE SENSITIVITY OF RADIONUCLIDE DETECTORS FOR CONDUCTING A MARITIME ON-BOARD SEARCH USING MONTE CARLO SIMULATION IMPLEMENTED IN AVERT

The sensitivity of two specific types of radionuclide detectors for conducting an on-board search in the maritime environment was evaluated using Monte Carlo simulation implemented in AVERT{reg_sign}. AVERT{reg_sign}, short for the Automated Vulnerability Evaluation for Risk of Terrorism, is personal computer based vulnerability assessment software developed by the ARES Corporation. The sensitivity of two specific types of radionuclide detectors for conducting an on-board search in the maritime environment was evaluated using Monte Carlo simulation. The detectors, a RadPack and also a Personal Radiation Detector (PRD), were chosen from the class of Human Portable Radiation Detection Systems (HPRDS). Human Portable Radiation Detection Systems (HPRDS) serve multiple purposes. In the maritime environment, there is a need to detect, localize, characterize, and identify radiological/nuclear (RN) material or weapons. The RadPack is a commercially available broad-area search device used for gamma and also for neutron detection. The PRD is chiefly used as a personal radiation protection device. It is also used to detect contraband radionuclides and to localize radionuclide sources. Neither device has the capacity to characterize or identify radionuclides. The principal aim of this study was to investigate the sensitivity of both the RadPack and the PRD while being used under controlled conditions in a simulated maritime environment for detecting hidden RN contraband. The detection distance varies by the source strength and the shielding present. The characterization parameters of the source are not indicated in this report so the results summarized are relative. The Monte Carlo simulation results indicate the probability of detection of the RN source at certain distances from the detector which is a function of transverse speed and instrument sensitivity for the specified RN source.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

DHS Regional Reachback: Rapid Expert Radiation Alarm Assistance.

Following assessments that attacks with radiological and nuclear weapons are possible, detection system deployments are being supported at national and local levels. Detection systems include both, highly sensitive but non-discriminating detectors, as well as detectors and algorithms capable of distinguishing and identifying gamma rays by energy. The latter systems, usually handheld systems based on sodium iodide detectors, also provide analysis of the specific radionuclides present and are referred to as radioisotope identifiers (RIIDs). Studies have shown that sodium iodide based RIIDs fall far short of 100% accurate identifications. The U.S. Department of Homeland Security (DHS) initiated the Regional Reachback (RRB) Program in 2006 to provide rapid expert interpretation of gamma spectroscopic data from radiation alarms from detection systems deployed by state and local authorities. With expert specialists on call 24/7, RRB provides an avenue for local and state authorities to verify routine results, interpret unknown identifications, and notify national response assets if needed. This paper will provide details of the RRE3 program, an outline of the analysis process, a description of the drills and training systems used to maintain specialists response performance, and examples of drills and incidents from the first full year of operation.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗