Search NASA⌕ Search

SEARCH · Search NASA

Results for “diagnostics”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 721 records · Page 40

A Novel UAV Electric Propulsion Testbed for Diagnostics and Prognostics

This paper presents a novel hardware-in-the-loop (HIL) testbed for systems level diagnostics and prognostics of an electric propulsion system used in UAVs (unmanned aerial vehicle). Referencing the all electric, Edge 540T aircraft used in science and research by NASA Langley Flight Research Center, the HIL testbed includes an identical propulsion system, consisting of motors, speed controllers and batteries. Isolated under a controlled laboratory environment, the propulsion system has been instrumented for advanced diagnostics and prognostics. To produce flight like loading on the system a slave motor is coupled to the motor under test (MUT) and provides variable mechanical resistance, and the capability of introducing nondestructive mechanical wear-like frictional loads on the system. This testbed enables the verification of mathematical models of each component of the propulsion system, the repeatable generation of flight-like loads on the system for fault analysis, test-to-failure scenarios, and the development of advanced system level diagnostics and prognostics methods. The capabilities of the testbed are extended through the integration of a LabVIEW-based client for the Live Virtual Constructive Distributed Environment (LVCDC) Gateway which enables both the publishing of generated data for remotely located observers and prognosers and the synchronization the testbed propulsion system with vehicles in the air. The developed HIL testbed gives researchers easy access to a scientifically relevant portion of the aircraft without the overhead and dangers encountered during actual flight.

Gorospe, George E., Jr.↗

Kepler Data Validation I: Architecture, Diagnostic Tests, and Data Products for Vetting Transiting Planet Candidates

The Kepler Mission was designed to identify and characterize transiting planets in the Kepler Field of View and to determine their occurrence rates. Emphasis was placed on identification of Earth-size planets orbiting in the Habitable Zone of their host stars. Science data were acquired for a period of four years. Long-cadence data with 29.4 min sampling were obtained for approx. 200,000 individual stellar targets in at least one observing quarter in the primary Kepler Mission. Light curves for target stars are extracted in the Kepler Science Data Processing Pipeline, and are searched for transiting planet signatures. A Threshold Crossing Event is generated in the transit search for targets where the transit detection threshold is exceeded and transit consistency checks are satisfied. These targets are subjected to further scrutiny in the Data Validation (DV) component of the Pipeline. Transiting planet candidates are characterized in DV, and light curves are searched for additional planets after transit signatures are modeled and removed. A suite of diagnostic tests is performed on all candidates to aid in discrimination between genuine transiting planets and instrumental or astrophysical false positives. Data products are generated per target and planet candidate to document and display transiting planet model fit and diagnostic test results. These products are exported to the Exoplanet Archive at the NASA Exoplanet Science Institute, and are available to the community. We describe the DV architecture and diagnostic tests, and provide a brief overview of the data products. Transiting planet modeling and the search for multiple planets on individual targets are described in a companion paper. The final revision of the Kepler Pipeline code base is available to the general public through GitHub. The Kepler Pipeline has also been modified to support the Transiting Exoplanet Survey Satellite (TESS) Mission which is expected to commence in 2018.

data analysis↗

Optical Diagnostic Imaging of Multi-Rocket Plume-Induced Base Flow Environments

Non-intrusive optical diagnostic imaging was used for the first time to visualize multi-rocket plume-induced reacting base flows to simulate launch vehicle ascent from sea-level to 250,000 ft. In particular, planar laser induced florescence (PLIF) and infrared (IR) imaging were implemented for the first time to visualize and quantify base flow and rocket plume environments from sub-scale, short-duration propulsion models within a shock tunnel facility. This report discusses the successful imaging diagnostic methods for capturing base flow features and dynamics as a function of altitude. Important base flow and plume features were captured with PLIF and IR diagnostics to develop a conceptual base flow physics model. This imaging data specifically provides insight into the Space Launch System vehicle core-stage and Exploration Upper Stage base environments and further validates short-duration ground test techniques and computational modeling.

Mehta, Manish↗

Self Diagnostic Accelerometer Field Programmable Gate Array (SDA FPGA)

A self-diagnostic accelerometer (SDA) field programmable gate array (FPGA) may be capable of real time or near-real time diagnostic processing to determine potential accelerometer issues during flight or other mission critical operational situations. The SDA FPGA may determine accelerometer structural health and an attachment condition using an electronics system that is smaller, more energy efficient, and more cost effective than previous diagnostic tools. Advantages of the system may include diagnosing sensors automatically, immediately, actively (i.e., confirming the fault), and consistently, without the influence of a human operator. Customizable SDA algorithms may be adjusted to the specific needs of the sensor/environment.

Tokars, Roger P.↗

EUV Diagnostics of Optically Thick Plasmas Using the 304 Å Channel

A fundamental limitation of current EUV diagnostic techniques is the need to neglect the He II emission contribution in the 304Å channel. This limits our ability to use strong observations available to us and increases uncertainties in the measurements made. A new EUV diagnostic technique is introduced that accounts for absorption as well as emission contributions from emitting channels such as 304 Å. This new technique can be equally applied to emitting and non-emitting channels, paving the way for more realistic discussion of the heating and energetics of transient plasmas using a wider range of observations. The diagnostic technique is used to compute the dynamics and energetics of a filament eruption observed in the high-cadence SDO/AIA and the associated ICME is observed by ACE/SWICS. The analysis gives us robust measurements of filament dynamics, energetics and its ionization history in the low solar corona. A comparison of these results with results calculated with techniques where He II emission in 304 Å is not considered allowed us to quantify the contribution from emission and comment on the robustness of our method.

EUV↗

Tuning the beam: a physics perspective on beam diagnostic instrumentation

In a nutshell, the role of a beam diagnostic measurement is to provide information needed to get a particle beam from Point A (injection point) to Point B (a target) in a useable condition, with 'useable' meaning the right energy and size and with acceptable losses. Specifications and performance requirements of diagnostics are based on the physics of the particle beam to be measured, with typical customers of beam parameter measurements being the accelerator operators and accelerator physicists. This tutorial will be a physics-oriented discussion of the interplay between tuning evolutions and the beam diagnostics systems that support the machine tune. This will include the differences between developing a tune and maintaining a tune, among other things. Practical longitudinal and transverse tuning issues and techniques from a variety of proton and electron machines will also be discussed.

43 PARTICLE ACCELERATORS↗

PERFORMANCE OF THE DIAGNOSTICS FOR NSLS-II LINAC COMMISSIONING

The National Synchrotron Light Source II (NSLS-II) is a state of the art 3-GeV third generation light source currently under construction at Brookhaven National Laboratory. The NSLS-II injection system consists of a 200 MeV linac, a 3-GeV booster synchrotron and associated transfer lines. The transfer lines not only provide a means to deliver the beam from one machine to another, they also provide a suite of diagnostics and utilities to measure the properties of the beam to be delivered. In this paper we discuss the suite of diagnostics that will be used to commission the NSLS-II linac and measure the beam properties. The linac to booster transfer line can measure the linac emittance with a three screens measurement or a quadrupole scan. Energy and energy spread are measured in a dispersive section. Total charge and charge uniformity are measured with wall current monitors in the linac and transformers in the transfer line. We show that the performance of the diagnostics in the transfer line will be sufficient to ensure the linac meets its specifications and provides a means of trouble shooting and studying the linac in future operation.

200 MeV linac↗

Slit disk for modified faraday cup diagnostic for determining power density of electron and ion beams

A diagnostic system for characterization of an electron beam or an ion beam includes an electrical conducting disk of refractory material having a circumference, a center, and a Faraday cup assembly positioned to receive the electron beam or ion beam. At least one slit in the disk provides diagnostic characterization of the electron beam or ion beam. The at least one slit is located between the circumference and the center of the disk and includes a radial portion that is in radial alignment with the center and a portion that deviates from radial alignment with the center. The electron beam or ion beam is directed onto the disk and translated to the at least one slit wherein the electron beam or ion beam enters the at least one slit for providing diagnostic characterization of the electron beam or ion beam.

47 OTHER INSTRUMENTATION↗

Evaluation of Magnetic Diagnostics for MHD Equilibrium Reconstruction of LHD Discharges

Equilibrium reconstruction is the process of determining the set of parameters of an MHD equilibrium that minimize the difference between expected and experimentally observed signals. This is routinely performed in axisymmetric devices, such as tokamaks, and the reconstructed equilibrium solution is then the basis for analysis of stability and transport properties. The V3FIT code [1] has been developed to perform equilibrium reconstruction in cases where axisymmetry cannot be assumed, such as in stellarators. The present work is focused on using V3FIT to analyze plasmas in the Large Helical Device (LHD) [2], a superconducting, heliotron type device with over 25 MW of heating power that is capable of achieving both high-beta ({approx}5%) and high density (>1 x 10{sup 21}/m{sup 3}). This high performance as well as the ability to drive tens of kiloamperes of toroidal plasma current leads to deviations in the equilibrium state from the vacuum flux surfaces. This initial study examines the effectiveness of using magnetic diagnostics as the observed signals in reconstructing experimental plasma parameters for LHD discharges. V3FIT uses the VMEC [3] 3D equilibrium solver to calculate an initial equilibrium solution with closed, nested flux surfaces based on user specified plasma parameters. This equilibrium solution is then used to calculate the expected signals for specified diagnostics. The differences between these expected signal values and the observed values provides a starting {chi}{sup 2} value. V3FIT then varies all of the fit parameters independently, calculating a new equilibrium and corresponding {chi}{sup 2} for each variation. A quasi-Newton algorithm [1] is used to find the path in parameter space that leads to a minimum in {chi}{sup 2}. Effective diagnostic signals must vary in a predictable manner with the variations of the plasma parameters and this signal variation must be of sufficient amplitude to be resolved from the signal noise. Signal effectiveness can be defined for a specific signal and specific reconstruction parameter as the dimensionless fractional reduction in the posterior parameter variance with respect to the signal variance. Here, {sigma}{sub i}{sup sig} is the variance of the ith signal and {sigma}{sub j}{sup param} param is the posterior variance of the jth fit parameter. The sum of all signal effectiveness values for a given reconstruction parameter is normalized to one. This quantity will be used to determine signal effectiveness for various reconstruction cases. The next section will examine the variation of the expected signals with changes in plasma pressure and the following section will show results for reconstructing model plasmas using these signals.

30 DIRECT ENERGY CONVERSION↗

Application of a tunable-diode-laser absorption diagnostic for CO measurements in an automotive HCCI engine.

An infrared laser absorption technique has been developed to measure in-cylinder concentrations of CO in an optical, automotive HCCI engine. The diagnostic employs a distributed-feedback, tunable diode laser selected to emit light at the R15 line of the first overtone of CO near 2.3 {micro}m. The collimated laser beam makes multiple passes through the cylinder to increase its path length and its sampling volume. High-frequency modulation of the laser output (wavelength modulation spectroscopy) further enhances the signal-to-noise ratio and detection limits of CO. The diagnostic has been tested in the motored and fired engine, exhibiting better than 200-ppm sensitivity for 50-cycle ensemble-average values of CO concentration with 1-ms time resolution. Fired results demonstrate the ability of the diagnostic to quantify CO production during negative valve overlap (NVO) for a range of fueling conditions.

33 ADVANCED PROPULSION SYSTEMS↗

2011 Laser Diagnostics in Combustion Gordon Research Conference, (August 14-19, 2011, Waterville Valley Resort, Waterville Valley, NH)

The vast majority of the world's energy needs are met by combustion of fossil fuels. Optimum utilization of limited resources and control of emissions of pollutants and greenhouse gases demand sustained improvement of combustion technology. This task can be satisfied only by detailed knowledge of the underlying physical and chemical processes. Non-intrusive laser diagnostics continuously contribute to our growing understanding of these complex and coupled multi-scale processes. The GRC on Laser Diagnostics in Combustion focuses on the most recent scientific advances and brings together scientists and engineers working at the leading edge of combustion research. Major tasks of the community are developing and applying methods for precise and accurate measurements of fluid motion and temperatures; chemical compositions; multi-phase phenomena appearing near walls, in spray and sooting combustion; improving sensitivities, precision, spatial resolution and tracking transients in their spatio-temporal development. The properties and behaviour of novel laser sources, detectors, optical systems that lead to new diagnostic capabilities are also part of the conference program.

42 ENGINEERING↗

"DIAGNOSTIC" PULSE FOR SINGLE-PARTICLE-LIKE BEAM POSITION MEASUREMENTS DURING ACCUMULATION/PRODUCTION MODE IN THE LOS ALAMOS PROTON STORAGE RING

Beam position monitors (BPMs) are the primary diagnostic in the Los Alamos Proton Storage Ring (PSR). When injecting one turn, the transversemotion is approximated as a single particle with initial betatron position and angle {rvec x}{sub 0} and {rvec x}'{sub 0}. With single-turn injection, we fit the betatron tune, closed orbit (CO), and injection offset ({rvec x}{sub 0} and {rvec x}'{sub 0} at the injection point) to the turn-by-turn beam position. In production mode, we accumulate multiple turns, the transverse phase space fills after 5 injections (horizontal and vertical fractional betatron tunes {approx}0.2) resulting in no coherent betatron motion, and only the CO may be measured. The injection offset, which determines the accumulated beam size and is very sensitive to steering upstream of the ring, is not measurable in production mode. We describe our approach and ongoing efforts to measure the injection offset during production mode by injecting a 'diagnostic' pulse {approx}50 {micro}s after the accumulated beam is extracted. We also study the effects of increasing the linac RF gate length to accommodate the diagnostic pulse on the production beam position, transverse size, and loss.

43 PARTICLE ACCELERATORS↗

ITER Diagnostic First Wal

The ITER Diagnostic Division is responsible for designing and procuring the First Wall Blankets that are mounted on the vacuum vessel port plugs at both the upper and equatorial levels This paper will discuss the effects of the diagnostic aperture shape and configuration on the coolant circuit design. The DFW design is driven in large part by the need to conform the coolant arrangement to a wide variety of diagnostic apertures combined with the more severe heating conditions at the surface facing the plasma, the first wall. At the first wall, a radiant heat flux of 35W/cm2 combines with approximate peak volumetric heating rates of 8W/cm3 (equatorial ports) and 5W/cm3 (upper ports). Here at the FW, a fast thermal response is desirable and leads to a thin element between the heat flux and coolant. This requirement is opposed by the wish for a thicker FW element to accommodate surface erosion and other off-normal plasma events.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Error field and magnetic diagnostic modeling for W7-X

The prediction, detection, and compensation of error fields for the W7-X device will play a key role in achieving a high beta (Β = 5%), steady state (30 minute pulse) operating regime utilizing the island divertor system [1]. Additionally, detection and control of the equilibrium magnetic structure in the scrape-off layer will be necessary in the long-pulse campaign as bootstrapcurrent evolution may result in poor edge magnetic structure [2]. An SVD analysis of the magnetic diagnostics set indicates an ability to measure the toroidal current and stored energy, while profile variations go undetected in the magnetic diagnostics. An additional set of magnetic diagnostics is proposed which improves the ability to constrain the equilibrium current and pressure profiles. However, even with the ability to accurately measure equilibrium parameters, the presence of error fields can modify both the plasma response and diverter magnetic field structures in unfavorable ways. Vacuum flux surface mapping experiments allow for direct measurement of these modifications to magnetic structure. The ability to conduct such an experiment is a unique feature of stellarators. The trim coils may then be used to forward model the effect of an applied n = 1 error field. This allows the determination of lower limits for the detection of error field amplitude and phase using flux surface mapping. *Research supported by the U.S. DOE under Contract No. DE-AC02-09CH11466 with Princeton University.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

First Steps Toward Incorporating Image Based Diagnostics Into Particle Accelerator Control Systems Using Convolutional Neural Networks

At present, a variety of image-based diagnostics are used in particle accelerator systems. Often times, these are viewed by a human operator who then makes appropriate adjustments to the machine. Given recent advances in using convolutional neural networks (CNNs) for image processing, it should be possible to use image diagnostics directly in control routines (NN-based or otherwise). This is especially appealing for non-intercepting diagnostics that could run continuously during beam operation. Here, we show results of a first step toward implementing such a controller: our trained CNN can predict multiple simulated downstream beam parameters at the Fermilab Accelerator Science and Technology (FAST) facility's low energy beamline using simulated virtual cathode laser images, gun phases, and solenoid strengths.

43 PARTICLE ACCELERATORS↗

Fiber-optic diagnostic system for future accelerator magnets

The next generation high energy physics accelerators will require magnetic fields at ~20 T. HTS coils will be an essential component of future accelerator magnets and several efforts are currently dedicated on designing 20 T HTS- LTS hybrid magnets. Among the existing challenges, there is the lack of a robust quench detection system for hybrid magnet technology. Another big challenge is represented by the high number of training quenches required by Nb3Sn magnets to reach performance level. In this framework it is important to find a tool that allow local real-time monitoring of magnet strain and temperature. In this paper, we propose the use of fiber optics sensors for diagnostic and quench detection in future accelerator superconducting magnets. Discrete and distributed fiber optic sensors have demonstrated to be a promising tool. The goal is to instrument hundreds of accelerator superconducting magnets and to move beyond the proof-of-concept level. Significant developments are still needed. Here, we are going to present the most recent results and discuss the most urgent technical developments in order to make those sensors a robust and reliable diagnostic tool for accelerator superconducting magnets over the next 10 year. We foresee that discrete fiber sensors will be a stable diagnostic probe for superconducting magnets over the next 3 to 5 years. More R&D work will be necessary for distributed fibers. The most urgent needs are the increase of sample rate and sensitivity. Close collaboration with vendors will be necessary to improve mechanical properties and fabrication processes in order to produce hundreds of meters of fiber and instrument a large number of accelerator superconducting magnets. Those R&D efforts will last up to 10 years with a founding level that spans between 5-10 M$.

43 PARTICLE ACCELERATORS↗

Survey of Machine Learning-Based Rotating Detonation Engine Diagnostics: Evaluation for Broad Application in Experimental Facilities

This work evaluates and compares various convolutional neural networks (CNNs) trained in previous NETL studies according to metrics effecting diagnostic feasibility, external applicability, and performance. Each CNN surveyed, including image classification, object detection, and time series classification, is used to develop total RDE diagnostics and evaluated alongside conventional techniques with respect to real-time capabilities. Real-time capable diagnostics are deployed and evaluated in the laboratory environment using an altered experimental setup, which is outlined herein for possible adaptations in external experimental facilities.

Johnson, Kristyn↗

Survey of Machine Learning-Based Rotating Detonation Engine Diagnostics: Evaluation for Broad Application in Experimental Facilities

This work evaluates and compares various convolutional neural networks (CNNs) trained in previous NETL studies according to metrics effecting diagnostic feasibility, external applicability, and performance. Each CNN surveyed, including image classification, object detection, and time series classification, is used to develop total RDE diagnostics and evaluated alongside conventional techniques with respect to real-time capabilities. Real-time capable diagnostics are deployed and evaluated in the laboratory environment using an altered experimental setup, which is outlined herein for possible adaptations in external experimental facilities.

Johnson, Kristyn↗