Search NASA⌕ Search

SEARCH · Search NASA

Results for “difference”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 721 records · Page 40

Differences in the dynamics of the tandem-SH2 modules of the Syk and ZAP-70 tyrosine kinases

The catalytic activity of Syk-family tyrosine kinases is regulated by a tandem Src homology 2 module (tSH2 module). In the autoinhibited state, this module adopts a conformation that stabilizes an inactive conformation of the kinase domain. The binding of the tSH2 module to phosphorylated immunoreceptor tyrosine-based activation motifs necessitates a conformational change, thereby relieving kinase inhibition and promoting activation. We determined the crystal structure of the isolated tSH2 module of Syk and find, in contrast to ZAP-70, that its conformation more closely resembles that of the peptide-bound state, rather than the autoinhibited state. Hydrogen–deuterium exchange by mass spectrometry, as well as molecular dynamics simulations, reveal that the dynamics of the tSH2 modules of Syk and ZAP-70 differ, with most of these differences occurring in the C-terminal SH2 domain. Our data suggest that the conformational landscapes of the tSH2 modules in Syk and ZAP-70 have been tuned differently, such that the autoinhibited conformation of the Syk tSH2 module is less stable. This feature of Syk likely contributes to its ability to more readily escape autoinhibition when compared to ZAP-70, consistent with tighter control of downstream signaling pathways in T cells.

59 BASIC BIOLOGICAL SCIENCES↗

Selecting a near-optimal design for multiple criteria with improved robustness to different user priorities

In a decision-making process, relying on only one objective can often lead to oversimplified decisions that ignore important considerations. Incorporating multiple, and likely competing, objectives is critical for balancing trade-offs on different aspects of performance. When multiple objectives are considered, it is often hard to make a precise decision on how to weight the different objectives when combining their performance for ranking and selecting designs. We show that there are situations when selecting a design with near-optimality for a broad range of weight combinations of the criteria is a better test selection strategy compared with choosing a design that is strictly optimal under very restricted conditions. Here, we propose a new design selection strategy that identifies several top-ranked solutions across broad weight combinations using layered Pareto fronts and then selects the final design that offers the best robustness to different user priorities. This method involves identifying multiple leading solutions based on the primary objectives and comparing the alternatives using secondary objectives to make the final decision. We focus on the selection of screening designs because they are widely used both in industrial research, development, and operational testing. The method is illustrated with an example of selecting a single design from a catalog of designs of a fixed size. However, the method can be adapted to more general designed experiment selection problems that involve searching through a large design space.

97 MATHEMATICS AND COMPUTING↗

The impact of different parameterizations on the interpretation of CP violation in neutrino oscillations

CP violation in the lepton mass matrix will be probed with good precision in upcoming experiments. The amount of CP violation present in oscillations can be quantified in numerous ways and is typically parameterized by the complex phase δ PDG in the standard PDG definition of the lepton mixing matrix. There are additional parameterizations of the lepton mixing matrix as well. Through various examples, we explore how, given the current data, different parameterizations can lead to different conclusions when working with parameterization dependent variables, such as δ. We demonstrate how the smallness of |U e3 | governs the scale of these results. We then demonstrate how δ can be misleading and argue that the Jarlskog is the cleanest means of presenting the amount of CP violation in the lepton sector. We also confirm that, among the different parameterizations considered, the standard PDG parameterization has a number of convenient features.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Measurement of the D → K - π + π + π- and D → K - π + π 0 coherence factors and average strong-phase differences in quantum-correlated $ D\overline{D} $ decays

The decays D → K - π + π + π - and D → K - π + π 0 are studied in a sample of quantum-correlated \( D\overline{D} \) pairs produced through the process e + e - → ψ (3770) → \( D\overline{D} \) , exploiting a data set collected by the BESIII experiment that corresponds to an integrated luminosity of 2.93 fb - 1 . Here D indicates a quantum superposition of a D 0 and a \( {\overline{D}}^0 \) meson. By reconstructing one neutral charm meson in a signal decay, and the other in the same or a different final state, observables are measured that contain information on the coherence factors and average strong-phase differences of each of the signal modes. These parameters are critical inputs in the measurement of the angle γ of the Unitarity Triangle in B - → DK - decays at the LHCb and Belle II experiments. The coherence factors are determined to be R K 3 π = \( {0.52}_{-0.10}^{+0.12} \) and \( {R}_{K{\pi \pi}^0} \) = 0 . 78 ± 0 . 04, with values for the average strong-phase differences that are \( {\delta}_D^{K3\pi }=\left({167}_{-19}^{+31}\right){}^{\circ} \) and \( {\delta}_D^{K{\pi \pi}^0}=\left({196}_{-15}^{+14}\right){}^{\circ} \) , where the uncertainties include both statistical and systematic contributions. The analysis is re-performed in four bins of the phase-space of the D → K - π + π + π - to yield results that will allow for a more sensitive measurement of γ with this mode, to which the BESIII inputs will contribute an uncertainty of around 6°.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Difference equations and integral families for Witten diagrams

We show that tree-level and one-loop Mellin space correlators in anti-de Sitter space obey certain difference equations, which are the direct analog to the differential equations for Feynman loop integrals in the flat space. Finite-difference relations, which we refer to as “summation-by-parts relations”, in parallel with the integration-by-parts relations for Feynman loop integrals, are derived to reduce the integrals to a basis. We illustrate the general methodology by explicitly deriving the difference equations and summation-by-parts relations for various tree-level and one-loop Witten diagrams up to the four-point bubble level.

AdS-CFT Correspondence↗

Stability of Balloon-Retention Gastrostomy Tubes with Different Concentrations of Contrast Material: In Vitro Study

The purpose of this study was to determine the performance of two balloon-retention-type gastrostomy tubes when the balloons are inflated with two types of contrast materials at different concentrations. Two commonly used balloon-retention-type tubes (MIC and Tri-Funnel) were inflated to the manufacturer's recommended volumes (4 and 20 cm{sup 3}, respectively) with normal saline or normal saline plus different concentrations of contrast material. Five tubes of each brand were inflated with normal saline and 0%, 25%, 50%, 75%, and 100% contrast material dilutions, using either nonionic hyperosmolar contrast, or nonionic iso-osmolar contrast. The tubes were submerged in a glass basin containing a solution with a pH of 4. Every week the tubes were visually inspected to determine the integrity of the balloons, and the diameter of the balloons was measured with a caliper. The tests were repeated every week for a total of 12 weeks. The MIC balloons deflated slightly faster over time than the Tri-Funnel balloons. The Tri-Funnel balloons remained relatively stable over the study period for the different concentrations of contrast materials. The deflation rates of the MIC balloons were proportionally related to the concentration of saline and inversely related to the concentration of the contrast material. At high contrast material concentrations, solidification of the balloons was observed. In conclusion, this in vitro study confirms that the use of diluted amounts of nonionic contrast materials is safe for inflating the balloons of two types of balloon-retention feeding tubes. High concentrations of contrast could result in solidification of the balloons and should be avoided.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Magnetic Thermal Ablation Using Ferrofluids: Influence of Administration Mode on Biological Effect in Different Porcine Tissues

The purpose of this study was to compare the effects of magnetic thermal ablation in different porcine tissues using either a singular injection or a continuous infusion of superparamagnetic iron oxide nanoparticles. In the first setting samples of three ferrofluids containing different amounts of iron (1:171, 2:192, and 3:214 mg/ml) were singularly interstitially injected into specimens of porcine liver, kidney, and muscle (n = 5). Then the specimens were exposed to an alternating magnetic field (2.86 kA/m, 190 kHz) generated by a circular coil for 5 min. In the second experimental setup ferrofluid samples were continuously interstitially infused into the tissue specimens during the exposure to the magnetic field. To measure the temperature increase two fiber-optic temperature probes with a fixed distance of 0.5 cm were inserted into the specimens along the puncture tract of the injection needle and the temperature was measured every 15 s. Finally, the specimens were dissected, the diameters of the created thermal lesions were measured, and the volumes were calculated and compared. Compared to continuous infusion, a single injection of ferrofluids resulted in smaller coagulation volumes in all tissues. Significant differences regarding coagulation volume were found in kidney and muscle specimens. The continuous infusion technique led to more elliptically shaped coagulation volumes due to larger diameters along the puncture tract. Our data show the feasibility of magnetic thermal ablation using either a single interstitial injection or continuous infusion for therapy of lesions in muscle, kidney, and liver. Continuous infusion of ferrofluids results in larger zones of necrosis compared to a single injection technique.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Microwave Ablation of Porcine Kidneys in vivo: Effect of two Different Ablation Modes ('Temperature Control' and 'Power Control') on Procedural Outcome

Purpose: This study was designed to analyze the effect of two different ablation modes ('temperature control' and 'power control') of a microwave system on procedural outcome in porcine kidneys in vivo. Methods: A commercially available microwave system (Avecure Microwave Generator; MedWaves, San Diego, CA) was used. The system offers the possibility to ablate with two different ablation modes: temperature control and power control. Thirty-two microwave ablations were performed in 16 kidneys of 8 pigs. In each animal, one kidney was ablated twice by applying temperature control (ablation duration set point at 60 s, ablation temperature set point at 96 Degree-Sign C, automatic power set point; group I). The other kidney was ablated twice by applying power control (ablation duration set point at 60 s, ablation temperature set point at 96 Degree-Sign C, ablation power set point at 24 W; group II). Procedural outcome was analyzed: (1) technical success (e.g., system failures, duration of the ablation cycle), and (2) ablation geometry (e.g., long axis diameter, short axis diameter, and circularity). Results: System failures occurred in 0% in group I and 13% in group II. Duration of the ablation cycle was 60 {+-} 0 s in group I and 102 {+-} 21 s in group II. Long axis diameter was 20.3 {+-} 4.6 mm in group I and 19.8 {+-} 3.5 mm in group II (not significant (NS)). Short axis diameter was 10.3 {+-} 2 mm in group I and 10.5 {+-} 2.4 mm in group II (NS). Circularity was 0.5 {+-} 0.1 in group I and 0.5 {+-} 0.1 in group II (NS). Conclusions: Microwave ablations performed with temperature control showed fewer system failures and were finished faster. Both ablation modes demonstrated no significant differences with respect to ablation geometry.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Outcomes After Transarterial Embolization of Neuroendocrine Tumor Liver Metastases Using Spherical Particles of Different Sizes

Purpose: To evaluate initial response and overall survival of neuroendocrine tumor (NET) liver metastases initially treated with transarterial embolization (TAE) using spherical particles of different sizes. Methods: A single-institution retrospective review was performed of 160 patients with NET liver metastases initially treated with TAE using < 100 µm (n = 77) or only ≥ 100 µm (n = 83) spherical particles. For each patient, we evaluated: initial response by mRECIST, time to progression, overall survival, complications, primary site, tumor grade and degree of differentiation, volume of liver disease, extrahepatic disease, NET-related symptoms, comorbidities, Child–Pugh score, performance status, lobar versus selective embolization, and arteriovenous shunting. Results: Initial response was higher for TAE using particles < 100 versus TAE using only particles ≥ 100 μm (64 vs 42%, p = 0.007). Multivariate logistic regression showed that use of particles < 100 μm and liver < 50% replaced with tumor were independent predictors of a better initial response rate. There was no difference in major or minor complications between the two particle size groups. Median overall survival after TAE was 55 months for well- to moderately differentiated NET and 13 months for poorly differentiated or undifferentiated NET. There was no significant difference in survival between TAE patients treated with < 100 versus only ≥ 100-μm particles. Conclusion: NET patients treated with TAE using particles < 100 μm had better initial response, but the same overall survival, compared to TAE using only particles ≥ 100 μm.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

An Ensemble Method for Classifying Regional Disease Patterns of Diffuse Interstitial Lung Disease Using HRCT Images from Different Vendors

We propose the use of ensemble classifiers to overcome inter-scanner variations in the differentiation of regional disease patterns in high-resolution computed tomography (HRCT) images of diffuse interstitial lung disease patients obtained from different scanners. A total of 600 rectangular 20 × 20-pixel regions of interest (ROIs) on HRCT images obtained from two different scanners (GE and Siemens) and the whole lung area of 92 HRCT images were classified as one of six regional pulmonary disease patterns by two expert radiologists. Textual and shape features were extracted from each ROI and the whole lung parenchyma. For automatic classification, individual and ensemble classifiers were trained and tested with the ROI dataset. We designed the following three experimental sets: an intra-scanner study in which the training and test sets were from the same scanner, an integrated scanner study in which the data from the two scanners were merged, and an inter-scanner study in which the training and test sets were acquired from different scanners. In the ROI-based classification, the ensemble classifiers showed better (p < 0.001) accuracy (89.73%, SD = 0.43) than the individual classifiers (88.38%, SD = 0.31) in the integrated scanner test. The ensemble classifiers also showed partial improvements in the intra- and inter-scanner tests. In the whole lung classification experiment, the quantification accuracies of the ensemble classifiers with integrated training (49.57%) were higher (p < 0.001) than the individual classifiers (48.19%). Furthermore, the ensemble classifiers also showed better performance in both the intra- and inter-scanner experiments. We concluded that the ensemble classifiers provide better performance when using integrated scanner images.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Retrospective Analysis of Clinical Performance of an Estonian Speech Recognition System for Radiology: Effects of Different Acoustic and Language Models

The aim of this study was to analyze retrospectively the influence of different acoustic and language models in order to determine the most important effects to the clinical performance of an Estonian language-based non-commercial radiology-oriented automatic speech recognition (ASR) system. An ASR system was developed for Estonian language in radiology domain by utilizing open-source software components (Kaldi toolkit, Thrax). The ASR system was trained with the real radiology text reports and dictations collected during development phases. The final version of the ASR system was tested by 11 radiologists who dictated 219 reports in total, in spontaneous manner in a real clinical environment. The audio files collected in the final phase were used to measure the performance of different versions of the ASR system retrospectively. ASR system versions were evaluated by word error rate (WER) for each speaker and modality and by WER difference for the first and the last version of the ASR system. Total average WER for the final version throughout all material was improved from 18.4% of the first version (v1) to 5.8% of the last (v8) version which corresponds to relative improvement of 68.5%. WER improvement was strongly related to modality and radiologist. In summary, the performance of the final ASR system version was close to optimal, delivering similar results to all modalities and being independent on user, the complexity of the radiology reports, user experience, and speech characteristics.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Environmental Particulars of Different Methods of Power Generation

The environmental and economic efficiency of different energy sources – coal, gas, shale gas, oil, wind, sun, water, nuclei, and others – is examined. The environmental indices of different methods of power generation are presented, the contribution of different types of energy carriers to electricity production and their prospects are indicated, and the environmentally most acceptable energy sources for sustainable development are named. A comprehensive index of the environmental impact is proposed.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

FTIR Imaging Coupled with Multivariate Analysis for Study of Initial Diffusion of Different Solvents in Cellulose Acetate Butyrate Films

Fourier transform infrared (FTIR) spectroscopic imaging was used to study the initial diffusion of different solvents in cellulose acetate butyrate (CAB) films containing different amounts of acetyl and butyryl substituents. Different solvents and solvent/non-solvent mixtures were also studied. The FTIR imaging system allowed acquisition of sequential images of the CAB films as solvent penetration proceeded without disturbing the system. The interface between the non-swollen polymer and the initial swelling front could be identified using multivariate data analysis tools. For a series of ketone solvents the initial diffusion coefficients and diffusion rates could be quantified and were found to be related to the polar and hydrogen interaction parameters in the Hansen solubility parameters of the solvents. For the solvent/non-solvent system the initial diffusion rate decreased less than linearly with the weight-percent of non-solvent present in the solution, which probably was due to the swelling characteristic of the non-solvent. For a given solvent, increasing the butyryl content of the CAB increased the initial diffusion rate. Increasing the butyryl content from 17 wt.% butyryl to 37 wt.% butyryl produced a considerably larger increase in initial diffusion rate compared to an increase in butyryl content from 37 wt.% to 50 wt.% butyryl.

14 SOLAR ENERGY↗

Comparison of Different Mo/Au TES Designs for Radiation Detectors

We report on the fabrication and characterization of Mo/Au-based transition-edge sensors (TES), intended to be used in X-ray detectors. We have performed complete dark characterization using I–V curves, complex impedance and noise measurements at different bath temperatures and biases. Devices with two designs, different sizes and different membranes have been characterized, some of them with a central bismuth absorber. This has allowed extraction of the relevant parameters of the TES, analyses of their standard behavior and evaluation of their prospects.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Aerobic Biodegradation of Aromatic Aliphatic Copolyester Induced by Bacteria Obtained from Different Environments

In this study the biodegradation characteristics of aromatic aliphatic copolyester Ecoflex was assayed with five different bacterial strains isolated from different kinds of environments and living at diverse optimum of temperature. The biodegradation properties of selected strains (Brevibacterium luteolum, Bacillus thuringiensis, Aeromonas media, Geobacillus kaustophilus and Serratia sp.) were assessed through several plate assays oriented to their proteolytic, lipolytic, esterolytic and cellulolytic abilities; catalase activities were measured too. In addition the bacterial hydrolytic abilities for polyhydroxybutyrate, polylactic acid and polybutyrate adipate terephthalate were obtained using specific culture media including also a specific Ecoflex agar. The biodegradation dynamics of selected strains were evaluated mainly by the incubation of Ecoflex foils with a specific bacterium during a period from 3 days until 16 weeks and the change of the degradability of the Ecoflex surface in nitrogen has been assessed by nonisothermal chemiluminescence measurements from 40 to 250 °C. Scanning electron microscope observation of inoculated foils was applied too. The comparison of the results showed the complexity of biodegradation phenomena. The concentration of oxygenated products measured by reached the maximum after 2 weeks of cultivation for strains G. kaustophilus and B. thurigiensis, after 4 weeks of cultivation for strain B. luteolum, and 8 weeks of cultivation for strains Serratia sp. and A. media. Each strain evidenced its own hydrolytic optimum at different periods, but almost all tested strains demonstrated a decline of hydrolysis up to 16 weeks of incubation. This study demonstrated that nonisothermal chemiluminescence examining momentaneous oxidation state of the polymer surface is a valuable technique to follow the biodegradation dynamics on polymeric film, while the Ecoflex agar is able to select useful polymer-degrading bacteria.

36 MATERIALS SCIENCE↗

Study on Nanocellulose Properties Processed Using Different Methods and Their Aerogels

In this paper the effects of different mechanical methods including homogenization, ultrasonication and grinding on the properties of the nanocellulose materials and their aerogels, were investigated. The cellulose nanocrystal products, (CNC-H) and (CNC-U), were prepared by homogenization and ultrasonication of the acid hydrolyzed pulps, respectively. The aerogel products were produced by solvent exchanging of nanocellulose hydrogels with tertiary butyl alcohol and followed by freeze drying. The nanocellulose materials were studied using transmission electron microscopy, field emission scanning electron microscopy (FE-SEM), Fourier transformed infrared spectroscopy (TEM), X-ray diffraction (XRD), thermal gravimetric analysis (TGA). Size distribution and surface charges of the nanocellulose suspensions were measured by zetasizer. Also, the morphology, the porosity properties and surface area of the CNCs and CNF aerogels were investigated via FE-SEM and nitrogen adsorption–desorption isotherms. The results showed that CNC-H has higher surface charge, suspension stability (− 41.8 mV), crystallinity index (74.7%) and better size dispersion than CNC-U and CNF with an average particle size of 122 nm. CNC-H microstructures demonstrated homogeneous network structure with smaller nanometer dimensions (15–30 nm width and 60–400 nm length). However, the CNC-H showed lower thermal stability compared to CNC-U and CNF. Larger average pore size (16.32 nm), pore volume (0.42 cc/g) and high specific surface area (> 100 m{sup 2} g{sup −1}) in CNC-H aerogel were obtained. Graphical Abstract: Suspensions of nanocellulose (NC) were prepared by different mechanical methods: Homogenizing, Ultrasonic and grinding. The NC products were investigated and their differences in morphology and other characteristics were studied. The aerogels were prepared from the nanocellulose hydrogels. The nitrogen physisorption was used to study the pore characteristics of the aerogels. .

36 MATERIALS SCIENCE↗

Ab Initio Study of Electronic and Magnetic Properties of Germanene with Different Nonmagnetic Metal Adatoms

Electronic and magnetic properties of two-dimensional (2D) germanene (Ge) with five different adatoms have been analyzed and discussed by the DFT method. Different nonmagnetic metals adsorbed at different sites, on one hand, a magnetic moment is induced by Mg adatom in the germanene. On the other hand, the adsorptions of Al, Ga, Li, and Na show no magnetism. We further study the effect of strain on the magnetism in Mg-adsorbed germanene; we apply an isotropic tensile and compressive strain on the system. On the basis of our calculations, a tunable magnetism shows as the strain increases. The analysis of the PDOS shows that the s–p hybridization between Mg and Ge atoms results in such magnetic behavior. These magneticadsorbed germanene materials might show potential applications in the nanoscale devices.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Conversion of Parameters Among Variants of Scatchard's Neutral-Electrolyte Model for Electrolyte Mixtures that Have Different Numbers of Mixing Terms

Various model equations are available for representing the excess Gibbs energy properties (osmotic and activity coefficients) of aqueous and other liquid mixed-electrolyte solutions. Scatchard's neutral-electrolyte model is among the simplest of these equations for ternary systems and contains terms that represent both symmetrical and asymmetric deviations from ideal mixing behavior when two single-electrolyte solutions are mixed in different proportions at constant ionic strengths. The usual form of this model allows from zero to six mixing parameters. In this report we present an analytical method for transforming the mixing parameters of neutral-electrolyte-type models with larger numbers of mixing parameters directly to those of models with fewer mixing parameters, without recourse to the source data used for evaluation of the original model parameters. The equations for this parameter conversion are based on an extension to ternary systems of the methodology of Rard and Wijesinghe [J. Chem. Thermodyn. 35, 439-473 (2003)] and Wijesinghe and Rard [J. Chem. Thermodyn. 37, 1196-1218 (2005)] that was applied by them to binary systems. It was found that the use of this approach with a constant ionic-strength cutoff of I {le} 6.2 mol {center_dot} kg{sup -1} (the NaCl solubility limit) yielded parameters for the NaCl + SrCl{sub 2} + H{sub 2}O and NaCl + MgCl{sub 2} + H{sub 2}O systems that predicted osmotic coefficients {phi} in excellent agreement with those calculated using the same sets of parameters whose values were evaluated directly from the source data by least-squares, with root mean square differences of RMSE({phi}) = 0.00006 to 0.00062 for the first system and RMSE({phi}) = 0.00014 to 0.00042 for the second. If, however, the directly evaluated parameters were based on experimental data where the ionic strength cutoff varied with the ionic-strength fraction, i.e. because they were constrained by isopiestic ionic strengths (MgCl{sub 2} + MgSO{sub 4} + H{sub 2}O) or solubility/oversaturation ionic strengths (NaCl + SrCl{sub 2} + H{sub 2}O and NaCl + MgCl{sub 2} + H{sub 2}O), then parameters converted by this approach assuming a constant ionic-strength cutoff yield RMSE({phi}) differences about an order of magnitude larger than the previous case. This indicates that for an accurate conversion of model parameters when the source model is constrained with variable ionic strength cutoffs, an extension of the parameter conversion method described herein will be required. However, when the source model parameters are evaluated at a constant ionic strength cutoff, such as when source isopiestic data are constrained to ionic strengths at or below the solubility limit of the less soluble component, or are Emf measurements that are commonly made at constant ionic strengths, then our method yields accurate converted models.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗