Search NASA⌕ Search

SEARCH · Search NASA

Results for “distributed control and estimation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 721 records · Page 40

Determining the minimum required uranium carbide content for HTGR UCO fuel kernels

There are three important failure mechanisms that must be controlled in high-temperature gas-cooled reactor (HTGR) fuel for certain higher burnup applications are SiC layer rupture, SiC corrosion by CO, and coating compromise from kernel migration. All are related to high CO pressures stemming from free O generated when uranium present as UO 2 fissions and the O is not subsequently bound by other elements. Furthermore, in the HTGR UCO kernel design, CO buildup from excess O is controlled by the inclusion of additional uranium in the form of a carbide, UC x . An approach for determining the minimum UC x content to ensure negligible CO formation was developed and demonstrated using CALPHAD models and the Serpent 2 reactor physics and depletion analysis tool. Our results are intended to be more accurate than previous estimates by including more nuclear and chemical factors, in particular the effect of transmutation products on the oxygen distribution as the fuel kernel composition evolves with burnup.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Reaction Kinetics of Water Molecules with Oxygen Vacancies on Rutile TiO 2 (110)

The formation of bridging hydroxyls (OHb) via reactions of water molecules with oxygen vacancies (VO) on reduced TiO 2 (110) surfaces is studied using infrared reflection-absorption spectroscopy (IRAS), electron-stimulated desorption (ESD), and photon-stimulated desorption (PSD). Narrow IRAS peaks at 2737 cm-1 and 3711 cm -1 are observed for stretching vibrations of OD b and OH b on TiO 2 (110), respectively. IRAS measurements with s- and p-polarized light demonstrate that the bridging hydroxyls are oriented normal to the (110) surface. The IR peaks disappear after the sample is exposed to O 2 or annealed in the temperature range of 400 – 600 K (correlating with the temperature at which pairs of OHb’s reform water and then desorb), which is consistent with their identification as bridging hydroxyls. We have studied the kinetics of water reacting with the vacancies by monitoring the formation of bridging hydroxyls (using IRAS) as a function of the annealing temperature for a small amount of water initially dosed on the TiO 2 (110) at low temperature. Separate experiments have also monitored the loss of water molecules (using water ESD) and vacancies (using the CO photooxidation reaction) due to the reactions of water molecules with the vacancies. All three techniques show that the reaction rate becomes appreciable for T > 150 K and that the reactions largely complete for T > 250 K. The temperature-dependent water-VO reaction kinetics are consistent with a Gaussian distribution of activation energies with E a = 0.545 eV, ΔE a (FWHM) = 0.125 eV, and a “normal” prefactor, v = 10 12 s -1 . In contrast, a single activation energy with a physically reasonable prefactor does not fit the data well. Our experimental activation energy is close to theoretical estimates for the diffusion of water molecules along the Ti 5c rows on the reduced TiO 2 (110) surface, which suggests that the diffusion of water controls the water – V O reaction rate.

74 ATOMIC AND MOLECULAR PHYSICS↗

A Control Variate Method for Probabilistic Performance Assessment. Improved Estimates for Mean Performance Quantities of Interest

We present a method of control variates for calculating improved estimates for mean performance quantities of interest, E(PQI) , computed from Monte Carlo probabilistic simulations. An example of a PQI is the concentration of a contaminant at a particular location in a problem domain computed from simulations of transport in porous media. To simplify the presentation, the method is described in the setting of a one- dimensional elliptical model problem involving a single uncertain parameter represented by a probability distribution. The approach can be easily implemented for more complex problems involving multiple uncertain parameters and in particular for application to probabilistic performance assessment of deep geologic nuclear waste repository systems. Numerical results indicate the method can produce estimates of E(PQI)having superior accuracy on coarser meshes and reduce the required number of simulations needed to achieve an acceptable estimate.

97 MATHEMATICS AND COMPUTING↗

Random field estimation approach to robot dynamics

The difference equations of Kalman filtering and smoothing recursively factor and invert the covariance of the output of a linear state-space system driven by a white-noise process. Here it is shown that similar recursive techniques factor and invert the inertia matrix of a multibody robot system. The random field models are based on the assumption that all of the inertial (D'Alembert) forces in the system are represented by a spatially distributed white-noise model. They are easier to describe than the models based on classical mechanics, which typically require extensive derivation and manipulation of equations of motion for complex mechanical systems. With the spatially random models, more primitive locally specified computations result in a global collective system behavior equivalent to that obtained with deterministic models. The primary goal of applying random field estimation is to provide a concise analytical foundation for solving robot control and motion planning problems.

Rodriguez, Guillermo↗

Improved Soundings and Error Estimates using AIRS/AMSU Data

AIRS was launched on EOS Aqua on May 4, 2002, together with AMSU A and HSB, to form a next generation polar orbiting infrared and microwave atmospheric sounding system. The primary products of AIRS/AMSU are twice daily global fields of atmospheric temperature-humidity profiles, ozone profiles, sea/land surface skin temperature, and cloud related parameters including OLR. The sounding goals of AIRS are to produce 1 km tropospheric layer mean temperatures with an rms error of 1 K, and layer precipitable water with an rms error of 20 percent, in cases with up to 80 percent effective cloud cover. The basic theory used to analyze AIRS/AMSU/HSB data in the presence of clouds, called the at-launch algorithm, and a post-launch algorithm which differed only in the minor details from the at-launch algorithm, have been described previously. The post-launch algorithm, referred to as AIRS Version 4.0, has been used by the Goddard DAAC to analyze and distribute AIRS retrieval products. In this paper we show progress made toward the AIRS Version 5.0 algorithm which will be used by the Goddard DAAC starting late in 2006. A new methodology has been developed to provide accurate case by case error estimates for retrieved geophysical parameters and for the channel by channel cloud cleared radiances used to derive the geophysical parameters from the AIRS/AMSU observations. These error estimates are in turn used for quality control of the derived geophysical parameters and clear column radiances. Improvements made to the retrieval algorithm since Version 4.0 are described as well as results comparing Version 5.0 retrieval accuracy and spatial coverage with those obtained using Version 4.0.

Susskind, Joel↗

Representative Day Selection Using Statistical Bootstrapping for Accelerating Annual Distribution Simulations

Capturing technical and economic impacts of solar photovoltaics (PV) and other distributed energy resources (DERs) on electric distribution systems can require high-time resolution (e.g. 1 minute), long-duration (e.g. 1 year) simulations. However, such simulations can be computationally prohibitive, particularly when including complex control schemes in quasi-steady-state time series (QSTS) simulation. Various approaches have been used in the literature to down select representative time segments (e.g. days), but typically these are best suited for lower time resolutions or consider only a single data stream (e.g. PV production) for selection. We present a statistical approach that combines stratified sampling and bootstrapping to select representative days while also providing a simple method to reassemble annual results. We describe the approach in the context of a recent study with a utility partner. This approach enables much faster QSTS analysis by simulating only a subset of days, while maintaining accurate annual estimates.

14 SOLAR ENERGY↗

Toward a Synthetic Model for Distribution System Restoration and Crew Dispatch

Distribution service restoration (DSR) is critical for improving the resilience and reliability of modern distribution systems by strategically and sequentially energizing the system components and customer loads. Restoring electricity service to affected customers also requires multiple crews with different skill sets to perform multiple tasks that are procedurally interdependent with safety guaranteed. However, in existing DSR practices, switch operations and crew dispatch are scheduled separately, and their interdependence is not fully considered. As advanced technologies are enabling remote communication, control, and dispatch, utilities now desire an integrated DSR framework to achieve seamless coordination among multiple DSR tasks such as switch operation, crew dispatch, and component repair. In this paper, we introduce a synthetic model that integrates the service restoration model and the crew dispatch model based on a universal routing model. The proposed model can provide the estimated time of restoration for each load, the switching sequence for safely operating remotely/manually operated switches, and dispatch solutions for crews with different skill sets. The proposed synthetic model is formulated as a mixed-integer linear programming model, and its effectiveness is evaluated via the IEEE 123 bus test feeder and several large-scale test feeders (EPRI Ckt5, Ckt7, Ckt24, and IEEE 8500 node test feeder.

24 POWER TRANSMISSION AND DISTRIBUTION↗

AGN Activity in Nucleated Galaxies as Measured by Chandra

Motivated by theoretical expectations that nuclear star clusters (NSCs) in galactic centers may provide a favorable environment for supermassive black holes to form and/or efficiently grow, we set out to measure the fraction of nearby nucleated galaxies that also host an active galactic nucleus. We targeted a distance-limited sample of 98 objects with the Chandra X-ray Telescope, down to a uniform X-ray luminosity threshold of ∼10{sup 38} erg s{sup −1}. The sample is composed of 47 late-types and 51 early-types, enabling us to further investigate the active fraction as a function of galactic morphology. After correcting for contamination to the nuclear X-ray signal from bright X-ray binaries, we measure an active fraction f=11.2%{sub −4.9}{sup +7.4} (1σ C.L.) across the whole sample, in agreement with previous estimates based on a heterogeneous combination of optical, X-ray, and radio diagnostics, by Seth et al. After accounting for the different stellar mass distributions in our samples, we find no statistically significant difference in the active fraction of early- versus late-type nucleated galaxies, with f=10.6%{sub −4.9}{sup +11.9} and 10.8%{sub −6.3}{sup +11.3}, respectively. For the early-type nucleated galaxies, we are able to carry out a controlled comparison with a parent sample of non-nucleated galaxies covering the same stellar mass range, again finding no statistically significant difference in the active fraction. Taken at face value, our findings suggest that the presence of an NSC does not facilitate or enhance accretion-powered emission from a nuclear supermassive black hole. This is true even for late-type nucleated galaxies, home to bluer NSCs and arguably larger gas reservoirs.

79 ASTRONOMY AND ASTROPHYSICS↗

GASP cloud encounter statistics - Implications for laminar flow control flight

The cloud observation archive from the NASA Global Atmospheric Sampling Program (GASP) is analyzed in order to derive the probability of cloud encounter at altitudes normally flown by commercial airliners, for application to a determination of the feasability of Laminar Flow Control (LFC) on long-range routes. The probability of cloud encounter is found to vary significantly with season. Several meteorological circulation features are apparent in the latitudinal distribution of cloud cover. The cloud encounter data are shown to be consistent with the classical midlatitude cyclone model with more clouds encountered in highs than in lows. Aircraft measurements of route-averaged time-in-clouds fit a gamma probability distribution model which is applied to estimate the probability of extended cloud encounter, and the associated loss of LFC effectiveness along seven high-density routes. The probability is demonstrated to be low.

Jasperson, W. H.↗

A Unique Test Facility to Measure Liner Performance with a Summary of Initial Test Results

A very ambitious study was initiated to obtain detailed acoustic and flow data with and without a liner in a duct containing a mean flow so that available theoretical models of duct liners can be validated. A unique flow-duct facility equipped with a sound source, liner box, flush-walled microphones, traversable microphones and traversable pressure and temperature probes was built. A unique set of instrumentation boxes equipped with computer controlled traverses were designed and built that allowed measurements of Mach number, temperature, SPLs and phases in two planes upstream of a liner section and two planes downstream at a large number of measurement points. Each pair of planes provided acoustic pressure gradients for use in estimating the particle velocities. Specially-built microphone probes were employed to make measurements in the presence of the flow. A microphone traverse was also designed to measure the distribution of SPLs and phases from the beginning of the liner to its end along the duct axis. All measurements were made with the help of cross-correlation techniques to reject flow noise and/or other obtrusive noise, if any. The facility was designed for future use at temperatures as high as 1500 F. In order to validate 2-D models in the presence of mean flow, the flow duct was equipped with a device to modify boundary layer flow on the smaller sides of a rectangular duct to simulate 2-D flow. A massive amount of data was acquired for use in validating duct liner models and will be provided to NASA in an electronic form. It was found that the sound in the plane-wave regime is well behaved within the duct and the results are repeatable from one run to another. At the higher frequencies corresponding to the higher-order modes, the SPLs within a duct are not repeatable from run to run. In fact, when two or more modes have the same frequency (i.e., for the degenerate modes), the SPLs in the duct varied between 2 dB to 12 dB from run to run. This made the calibration of the microphone probes extremely difficult at the higher frequencies.

Ahuja, K. K.↗

Modular Battery Charge Controller

A new approach to masterless, distributed, digital-charge control for batteries requiring charge control has been developed and implemented. This approach is required in battery chemistries that need cell-level charge control for safety and is characterized by the use of one controller per cell, resulting in redundant sensors for critical components, such as voltage, temperature, and current. The charge controllers in a given battery interact in a masterless fashion for the purpose of cell balancing, charge control, and state-of-charge estimation. This makes the battery system invariably fault-tolerant. The solution to the single-fault failure, due to the use of a single charge controller (CC), was solved by implementing one CC per cell and linking them via an isolated communication bus [e.g., controller area network (CAN)] in a masterless fashion so that the failure of one or more CCs will not impact the remaining functional CCs. Each micro-controller-based CC digitizes the cell voltage (V(sub cell)), two cell temperatures, and the voltage across the switch (V); the latter variable is used in conjunction with V(sub cell) to estimate the bypass current for a given bypass resistor. Furthermore, CC1 digitizes the battery current (I1) and battery voltage (V(sub batt) and CC5 digitizes a second battery current (I2). As a result, redundant readings are taken for temperature, battery current, and battery voltage through the summation of the individual cell voltages given that each CC knows the voltage of the other cells. For the purpose of cell balancing, each CC periodically and independently transmits its cell voltage and stores the received cell voltage of the other cells in an array. The position in the array depends on the identifier (ID) of the transmitting CC. After eight cell voltage receptions, the array is checked to see if one or more cells did not transmit. If one or more transmissions are missing, the missing cell(s) is (are) eliminated from cell-balancing calculations. The cell-balancing algorithm is based on the error between the cell s voltage and the other cells and is categorized into four zones of operation. The algorithm is executed every second and, if cell balancing is activated, the error variable is set to a negative low value. The largest error between the cell and the other cells is found and the zone of operation determined. If the error is zero or negative, then the cell is at the lowest voltage and no balancing action is needed. If the error is less than a predetermined negative value, a Cell Bad Flag is set. If the error is positive, then cell balancing is needed, but a hysteretic zone is added to prevent the bypass circuit from triggering repeatedly near zero error. This approach keeps the cells within a predetermined voltage range.

Button, Robert↗

Natural Gas Drilling near the Underground Nuclear Test Site of Rulison, Colorado - 19571

In 1969, the Project Rulison test was conducted in western Colorado using a nuclear device to stimulate natural gas production by fracturing low-permeability, gas-bearing rock. The presence of radionuclides (specifically tritium) in the produced gas persisted above acceptable levels, and the test was abandoned. Advances in hydrofracturing technology over the past 10-15 years have revolutionized the extraction of hydrocarbons from low-permeability formations, leading to a significant increase of drilling in the Rulison area. Drilling activity nearing the Rulison site has raised concerns that remnant radioactivity might be encountered. The site, now under the care of the US Department of Energy (DOE), is protected by a 16-hectare (40 acre) institutional control boundary (Lot 11) that prohibits drilling or extraction of materials below 1830 meters (6000 feet) within the lot boundary. Drilling within 0.8 kilometer (0.5 mile) of the site requires a hearing before the Colorado Oil and Gas Conservation Commission. DOE recommends that gas developers adopt a conservative, staged drilling approach, allowing gas reserves near the Rulison site to be recovered in a manner that minimizes the likelihood of encountering contamination. The staged approach calls for collecting data from wells away from the site before drilling closer. For instance, the wells 1.2 kilometer (0.75 mile) west of the site did not encounter any unexpected geologic conditions and now have 8 years of production without encountering any detonation-related radionuclides. The next set of wells would be 0.8 kilometer (0.5 mile) west of the site. This sequential method drills first at locations with a low probability of encountering contamination and then moves closer. This process protects public safety while allowing the collection of additional data to confirm that contamination has not migrated beyond the 16-hectare (40-acre) institutional control boundary. The staged drilling approach was simulated with a modeling effort that estimates the current extent of contamination and the potential for production-induced contaminant migration to nearby wells. The model incorporates geologic data from nearby wells and was calibrated to production data from both the reentry well production testing (1970-1971) and the wells 1.2 kilometer (0.75 mile) from the site that began producing in 2010. The geologic data include both sand/shale distribution statistics as well as the tendency of hydrofractures to preferentially propagate east and west due to the regional stress field. The model results indicate that it is unlikely that wells near the site would ever encounter site-related radionuclides. (authors)

03 NATURAL GAS↗

Distributed control of electric power grids

A method for determining power output levels of a plurality of nodes in an electric power system includes receiving, at a first node of the plurality of nodes, voltage information and multipliers of all neighboring nodes of the first node within the electric power system, determining, by the first node, a local power generation and a local voltage using the voltage information and the multipliers of the neighboring nodes and distributing the local power generation and the local voltage to the neighboring nodes, determining, by the first node, an estimated voltage of each of the neighboring nodes and distributing the estimated voltage to each of the neighboring nodes, and updating, by the first node, a local multiplier using the voltage information received from the neighboring nodes and the estimated voltage of each of the neighboring nodes determined by the node.

Ghosh, Soumyadip↗

Numerical evaluation of photosensitive tracers as a strategy for separating surface and subsurface transient storage in streams

For this work, we numerically evaluated photosensitive tracers as a potential strategy for separating the effects of surface and hyporheic storage zones (SSZs and HSZs, respectively) on stream corridor transport. Correctly separating HSZ and SSZ effects is critical to estimating the hydro-biogeochemical function of a stream because HSZs and SSZs expose solutes to significantly different biogeochemical conditions, like sunlight exposure, microbial processes, and oxygen availability. Our numerical experiments used a multiscale river-corridor transport model implemented in the ATS code, which accommodates multiple storage zones with distinct travel time distributions and biogeochemical reactions. For parameter inferences, we used Bayesian inverse modeling. We found that breakthrough curves for photo-decaying tracers from day and night injection can delineate surface and hyporheic transient storage contributions, but only when interpreted jointly through a two-storage zone model. Numerical experiments that used only daytime injection or interpreted breakthrough curves with a single storage zone model yielded good fit to breakthrough curves, but parameter estimates were biased and controlling processes misattributed, examples of good model fits for the wrong reasons. Using those biased parameter estimates in reactive transport simulations resulted in significantly different projections of denitrification, which underscores the potential for stream function to be mischaracterized if tracer tests are interpreted through an inappropriately simplified model for transient storage. More generally, this study highlights the role of modeling in evaluating the experimental design and identifying the potential of system mischaracterization and its implications.

54 ENVIRONMENTAL SCIENCES↗

State-of-the art of dc components for secondary power distribution of Space Station Freedom

120-V dc secondary power distribution has been selected for Space Station Freedom. State-of-the art components and subsystems are examined in terms of performance, size, and topology. One of the objectives of this work is to inform Space Station users what is available in power supplies and power control devices. The other objective is to stimulate interest in the component industry so that more focused product development can be started. Based on results of this study, it is estimated that, with some redesign, modifications, and space qualification, may of these components may be applied to Space Station needs.

Krauthamer, Stanley↗

Effects of window size and shape on accuracy of subpixel centroid estimation of target images

A new algorithm is presented for increasing the accuracy of subpixel centroid estimation of (nearly) point target images in cases where the signal-to-noise ratio is low and the signal amplitude and shape vary from frame to frame. In the algorithm, the centroid is calculated over a data window that is matched in width to the image distribution. Fourier analysis is used to explain the dependency of the centroid estimate on the size of the data window, and simulation and experimental results are presented which demonstrate the effects of window size for two different noise models. The effects of window shape were also investigated for uniform and Gaussian-shaped windows. The new algorithm was developed to improve the dynamic range of a close-range photogrammetric tracking system that provides feedback for control of a large gap magnetic suspension system (LGMSS).

Welch, Sharon S.↗

Wrinkle ridges of Arcadia Planitia, Mars

Wrinkle ridges of Arcadia Planitia were examined to determine their morphology, spatial distribution, and the amount of crustal shortening and strain they accommodate. Ridges trend generally northward, but their orientation and distribution are strongly controlled by the relief of the underlying hobby material. Ridges begin or end at inselbergs of older terrain and are associated with buried craters. Arcadia Planitia ridges have an average width of 3425 m and accommodate an average folding shortening of 3 m and a faulting shortening of 55 m; mean total shortening is 57 m. Three east-west transects were constructed at 20 deg 25 deg and 28 deg N to estimate regional shortening and strain. Average total shortening across the transects is about 900 m, corresponding to a regional compressive strain of 0.06 percent. The total shortening and compression across Arcadia Planitia are less than in Lungae Planum. Faults associated with the Arcadia ridges are inferred to have a westward dip compared with an eastward dip for Lungae Planum ridges. The general levels of compression and symmetric orientation of the ridges suggest a regionally organized stress system.

Plescia, J. B.↗

Control of a Flexible Space Antenna: A Finite Dimensional Perspective Based on Distributed Parameter Theory

The methods presented are based on results from infinite dimensional control theory, but they can be described and used in a finite dimensional context. This blend leads to an approach which employs powerful ideas on convergence, and is also quite practical for systems of realistic complexity. Appropriate reduced order models are generated simultaneously with the development of the compensator. The required models change as a function of changes in the performance demanded, sensor and actuator location, inherent damping, disturbances, etc. Thus they are driven by the control and estimation problems at hand. The compensators which emerge are very close to the ideal compensators which would be obtained with a very large order model. However, some simplification is frequently possible. The method of balanced realizations was found to be effective for this purpose.

Mingori, D. L.↗