Search NASA⌕ Search

SEARCH · Search NASA

Results for “errors”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 721 records · Page 40

SU-E-T-631: Preliminary Results for Analytical Investigation Into Effects of ArcCHECK Setup Errors

Purpose: As three-dimensional diode arrays increase in popularity for patient-specific quality assurance for intensity-modulated radiation therapy (IMRT), it is important to evaluate an array’s susceptibility to setup errors. The ArcCHECK phantom is set up by manually aligning its outside marks with the linear accelerator’s lasers and light-field. If done correctly, this aligns the ArcCHECK cylinder’s central axis (CAX) with the linear accelerator’s axis of rotation. However, this process is prone to error. This project has developed an analytical expression including a perturbation factor to quantify the effect of shifts. Methods: The ArcCHECK is set up by aligning its machine marks with either the sagittal room lasers or the light-field of the linear accelerator at gantry zero (IEC). ArcCHECK has sixty-six evenly-spaced SunPoint diodes aligned radially in a ring 14.4 cm from CAX. The detector response function (DRF) was measured and combined with inverse-square correction to develop an analytical expression for output. The output was calculated using shifts of 0 (perfect alignment), +/−1, +/−2 and +/−5 mm. The effect on a series of simple inputs was determined: unity, 1-D ramp, steps, and hat-function to represent uniform field, wedge, evenly-spaced modulation, and single sharp modulation, respectively. Results: Geometric expressions were developed with perturbation factor included to represent shifts. DRF was modeled using sixth-degree polynomials with correlation coefficient 0.9997. The output was calculated using simple inputs such as unity, 1-D ramp, steps, and hat-function, with perturbation factors of: 0, +/−1, +/−2 and +/−5 mm. Discrepancies have been observed, but large fluctuations have been somewhat mitigated by aliasing arising from discrete diode placement. Conclusion: An analytical expression with perturbation factors was developed to estimate the impact of setup errors on an ArcCHECK phantom. Presently, this has been applied to simple functions, but is being developed to handle more realistic clinical cases.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

TU-AB-201-05: Automatic Adaptive Per-Operative Re-Planning for HDR Prostate Brachytherapy - a Simulation Study On Errors in Needle Positioning

Purpose: To develop adaptive planning with feedback for MRI-guided focal HDR prostate brachytherapy with a single divergent needle robotic implant device. After each needle insertion, the dwell positions for that needle are calculated and the positioning of remaining needles and dosimetry are both updated based on MR imaging. Methods: Errors in needle positioning may occur due to inaccurate needle insertion (caused by e.g. the needle’s bending) and unpredictable changes in patient anatomy. Consequently, the dose plan quality might dramatically decrease compared to the preplan. In this study, a procedure was developed to re-optimize, after each needle insertion, the remaining needle angulations, source positions and dwell times in order to obtain an optimal coverage (D95% PTV>19 Gy) without exceeding the constraints of the organs at risk (OAR) (D10% urethra<21 Gy, D1cc bladder<12 Gy and D1cc rectum<12 Gy). Complete HDR procedures with 6 needle insertions were simulated for a patient MR-image set with PTV, prostate, urethra, bladder and rectum delineated. Random angulation errors, modeled by a Gaussian distribution (standard deviation of 3 mm at the needle’s tip), were generated for each needle insertion. We compared the final dose parameters for the situations (I) without re-optimization and (II) with the automatic feedback. Results: The computation time of replanning was below 100 seconds on a current desk computer. For the patient tested, a clinically acceptable dose plan was achieved while applying the automatic feedback (median(range) in Gy, D95% PTV: 19.9(19.3–20.3), D10% urethra: 13.4(11.9–18.0), D1cc rectum: 11.0(10.7–11.6), D1cc bladder: 4.9(3.6–6.8)). This was not the case without re-optimization (median(range) in Gy, D95% PTV: 19.4(14.9–21.3), D10% urethra: 12.6(11.0–15.7), D1cc rectum: 10.9(8.9–14.1), D1cc bladder: 4.8(4.4–5.2)). Conclusion: An automatic guidance strategy for HDR prostate brachytherapy was developed to compensate errors in needle positioning and improve the dose distribution. Without re-optimization, target coverage and OAR constraints may not be achieved. M. Borot de Battisti is funded by Philips Medical Systems Nederland B.V.; M. Moerland is principal investigator on a contract funded by Philips Medical Systems Nederland B.V.; G. Hautvast and D. Binnekamp are full-time employees of Philips Medical Systems Nederland B.V.

60 APPLIED LIFE SCIENCES↗

TU-G-BRD-01: Quantifying the Effectiveness of the Physics Pre-Treatment Plan Review for Detecting Errors in Radiation Therapy

Purpose: Physics pre-treatment plan review is crucial to safe radiation oncology treatments. Studies show that most errors originate in treatment planning, which underscores the importance of physics plan review. As a QA measure the physics review is of fundamental importance and is central to the profession of medical physics. However, little is known about its effectiveness. More hard data are needed. The purpose of this study was to quantify the effectiveness of physics review with the goal of improving it. Methods: This study analyzed 315 “potentially serious” near-miss incidents within an institutional incident learning system collected over a two-year period. 139 of these originated prior to physics review and were found at the review or after. Incidents were classified as events that: 1)were detected by physics review, 2)could have been detected (but were not), and 3)could not have been detected. Category 1 and 2 events were classified by which specific check (within physics review) detected or could have detected the event. Results: Of the 139 analyzed events, 73/139 (53%) were detected or could have been detected by the physics review; although, 42/73 (58%) were not actually detected. 45/73 (62%) errors originated in treatment planning, making physics review the first step in the workflow that could detect the error. Two specific physics checks were particularly effective (combined effectiveness of >20%): verifying DRRs (8/73) and verifying isocenter (7/73). Software-based plan checking systems were evaluated and found to have potential effectiveness of 40%. Given current data structures, software implementations of some tests such as isocenter verification check would be challenging. Conclusion: Physics plan review is a key safety measure and can detect majority of reported events. However, a majority of events that potentially could have been detected were NOT detected in this study, indicating the need to improve the performance of physics review.

60 APPLIED LIFE SCIENCES↗

SU-G-JeP3-02: Comparison of Magnitude and Frequency of Patient Positioning Errors in Breast Irradiation Using AlignRT 3D Optical Surface Imaging and Skin Mark Techniques

Purpose: To evaluate clinical usefulness of AlignRT (Vision RT Ltd., London, UK) in reducing patient positioning errors in breast irradiation. Methods: 60 patients undergoing whole breast irradiation were selected for this study. Patients were treated to the left or right breast lying on Qfix Access breast board (Qfix, Avondale, PA) in supine position for 28 fractions using tangential fields. 30 patients were aligned using AlignRT by aligning a breast surface region of interest (ROI) to the same area from a reference surface image extracted from planning CT. When the patient’s surface image deviated from the reference by more than 3mm on one or more translational and rotational directions, a new reference was acquired using AlignRT in-room cameras. The other 30 patients were aligned to the skin marks with room lasers. On-Board MV portal images of medial field were taken daily and matched to the DRRs. The magnitude and frequency of positioning errors were determined from measured translational shifts. Kolmogorov-Smirnov test was used to evaluate statistical differences of positional accuracy and precision between AlignRT and non-AlignRT patients. Results: The percentage of port images with no shift required was 46.5% and 27.0% in vertical, 49.8% and 25.8% in longitudinal, 47.6% and 28.5% in lateral for AlignRT and non-AlignRT patients, respectively. The percentage of port images requiring more than 3mm shifts was 18.1% and 35.1% in vertical, 28.6% and 50.8% in longitudinal, 11.3% and 24.2% in lateral for AlignRT and non-AlignRT patients, respectively. Kolmogorov-Smirnov test showed that there were significant differences between the frequency distributions of AlignRT and non-AlignRT in vertical, longitudinal, and lateral shifts. Conclusion: As confirmed by port images, AlignRT-assisted patient positioning can significantly reduce the frequency and magnitude of patient setup errors in breast irradiation compared to the use of lasers and skin marks.

60 APPLIED LIFE SCIENCES↗

The effectiveness of pretreatment physics plan review for detecting errors in radiation therapy

Purpose: The pretreatment physics plan review is a standard tool for ensuring treatment quality. Studies have shown that the majority of errors in radiation oncology originate in treatment planning, which underscores the importance of the pretreatment physics plan review. This quality assurance measure is fundamentally important and central to the safety of patients and the quality of care that they receive. However, little is known about its effectiveness. The purpose of this study was to analyze reported incidents to quantify the effectiveness of the pretreatment physics plan review with the goal of improving it. Methods: This study analyzed 522 potentially severe or critical near-miss events within an institutional incident learning system collected over a three-year period. Of these 522 events, 356 originated at a workflow point that was prior to the pretreatment physics plan review. The remaining 166 events originated after the pretreatment physics plan review and were not considered in the study. The applicable 356 events were classified into one of the three categories: (1) events detected by the pretreatment physics plan review, (2) events not detected but “potentially detectable” by the physics review, and (3) events “not detectable” by the physics review. Potentially detectable events were further classified by which specific checks performed during the pretreatment physics plan review detected or could have detected the event. For these events, the associated specific check was also evaluated as to the possibility of automating that check given current data structures. For comparison, a similar analysis was carried out on 81 events from the international SAFRON radiation oncology incident learning system. Results: Of the 356 applicable events from the institutional database, 180/356 (51%) were detected or could have been detected by the pretreatment physics plan review. Of these events, 125 actually passed through the physics review; however, only 38% (47/125) were actually detected at the review. Of the 81 events from the SAFRON database, 66/81 (81%) were potentially detectable by the pretreatment physics plan review. From the institutional database, three specific physics checks were particularly effective at detecting events (combined effectiveness of 38%): verifying the isocenter (39/180), verifying DRRs (17/180), and verifying that the plan matched the prescription (12/180). The most effective checks from the SAFRON database were verifying that the plan matched the prescription (13/66) and verifying the field parameters in the record and verify system against those in the plan (23/66). Software-based plan checking systems, if available, would have potential effectiveness of 29% and 64% at detecting events from the institutional and SAFRON databases, respectively. Conclusions: Pretreatment physics plan review is a key safety measure and can detect a high percentage of errors. However, the majority of errors that potentially could have been detected were not detected in this study, indicating the need to improve the pretreatment physics plan review performance. Suggestions for improvement include the automation of specific physics checks performed during the pretreatment physics plan review and the standardization of the review process.

60 APPLIED LIFE SCIENCES↗

Effects of error, chimera, bias, and GC content on the accuracy of amplicon sequencing

ABSTRACT Targeted amplicon sequencing is widely used in microbial ecology studies. However, sequencing artifacts and amplification biases are of great concern. To identify sources of these artifacts, a systematic analysis was performed using mock communities comprised of 16S rRNA genes from 33 bacterial strains. Our results indicated that while sequencing errors were generally isolated to low-abundance operational taxonomic units, chimeric sequences were a major source of artifacts. Singleton and doubleton sequences were primarily chimeras. Formation of chimeric sequences was significantly correlated with the GC content of the targeted sequences. Low-GC-content mock community members exhibited lower rates of chimeric sequence formation. GC content also had a large impact on sequence recovery. The quantitative capacity was notably limited, with substantial recovery variations and weak correlation between anticipated and observed strain abundances. The mock community strains with higher GC content had higher recovery rates than strains with lower GC content. Amplification bias was also observed due to the differences in primer affinity. A two-step PCR strategy reduced the number of chimeric sequences by half. In addition, comparative analyses based on the mock communities showed that several widely used sequence processing pipelines/methods, including DADA2, Deblur, UCLUST, UNOISE, and UPARSE, had different advantages and disadvantages in artifact removal and rare species detection. These results are important for improving sequencing quality and reliability and developing new algorithms to process targeted amplicon sequences. IMPORTANCE Amplicon sequencing of targeted genes is the predominant approach to estimate the membership and structure of microbial communities. However, accurate reconstruction of community composition is difficult due to sequencing errors, and other methodological biases and effective approaches to overcome these challenges are essential. Using a mock community of 33 phylogenetically diverse strains, this study evaluated the effect of GC content on sequencing results and tested different approaches to improve overall sequencing accuracy while characterizing the pros and cons of popular amplicon sequence data processing approaches. The sequencing results from this study can serve as a benchmarking data set for future algorithmic improvements. Furthermore, the new insights on sequencing error, chimera formation, and GC bias from this study will help enhance the quality of amplicon sequencing studies and support the development of new data analysis approaches.

59 BASIC BIOLOGICAL SCIENCES↗

Simultaneous Sensing Error Recovery and Tomographic Inversion Using an Optimization-Based Approach

Tomography can be used to reveal internal properties of a 3D object using any penetrating wave. Advanced tomographic imaging techniques, however, are vulnerable to both systematic and random errors associated with the experimental conditions, which are often beyond the capabilities of the state-of-the-art reconstruction techniques such as regularizations. Because they can lead to reduced spatial resolution and even misinterpretation of the underlying sample structures, these errors present a fundamental obstacle to full realization of the capabilities of next-generation physical imaging. In this work, we develop efficient and explicit recovery schemes of the most common experimental error: movement of the center of rotation during the experiment. We formulate new physical models to capture the experimental setup, and we devise new mathematical optimization formulations for reliable inversion of complex samples. We demonstrate and validate the efficacy of our approach on synthetic data under known perturbations of the center of rotation.

Nonlinear optimization↗

A Survey on Error-Bounded Lossy Compression for Scientific Datasets

Error-bounded lossy compression has been effective in significantly reducing the data storage/transfer burden while preserving the reconstructed data fidelity very well. Many error-bounded lossy compressors have been developed for a wide range of parallel and distributed use cases for years. They are designed with distinct compression models and principles, such that each of them features particular pros and cons. In this article, we provide a comprehensive survey of emerging error-bounded lossy compression techniques. The key contribution is fourfold. (1) We summarize a novel taxonomy of lossy compression into six classic models. (2) We provide a comprehensive survey of 10 commonly used compression components/modules. (3) We summarized pros and cons of 47 state-of-the-art lossy compressors and present how state-of-the-art compressors are designed based on different compression techniques. (4) We discuss how customized compressors are designed for specific scientific applications and use-cases. We believe this survey is useful to multiple communities including scientific applications, high-performance computing, lossy compression, and big data.

Error-Bounded Lossy Compression↗

Synthetic aperture interferometry: error analysis

Synthetic aperture interferometry (SAI) is a novel way of testing aspherics and has a potential for in-process measurement of aspherics [Appl. Opt.42, 701 (2003)].APOPAI0003-693510.1364/AO.42.000701 A method to measure steep aspherics using the SAI technique has been previously reported [Appl. Opt.47, 1705 (2008)].APOPAI0003-693510.1364/AO.47.001705 Here we investigate the computation of surface form using the SAI technique in different configurations and discuss the computational errors. A two-pass measurement strategy is proposed to reduce the computational errors, and a detailed investigation is carried out to determine the effect of alignment errors on the measurement process.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Random errors in interferometry with the least-squares method

This investigation analyzes random errors in interferometric surface profilers using the least-squares method when random noises are present. Two types of random noise are considered here: intensity noise and position noise. Two formulas have been derived for estimating the standard deviations of the surface height measurements: one is for estimating the standard deviation when only intensity noise is present, and the other is for estimating the standard deviation when only position noise is present. Measurements on simulated noisy interferometric data have been performed, and standard deviations of the simulated measurements have been compared with those theoretically derived. The relationships have also been discussed between random error and the wavelength of the light source and between random error and the amplitude of the interference fringe.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Superdense coding interleaved with forward error correction

Superdense coding promises increased classical capacity and communication security but this advantage may be undermined by noise in the quantum channel. We present a numerical study of how forward error correction (FEC) applied to the encoded classical message can be used to mitigate against quantum channel noise. By studying the bit error rate under different FEC codes, we identify the unique role that burst errors play in superdense coding, and we show how these can be mitigated against by interleaving the FEC codewords prior to transmission. As a result, we conclude that classical FEC with interleaving is a useful method to improve the performance in near-term demonstrations of superdense coding.

97 MATHEMATICS AND COMPUTING↗

Utilizing Adjoint-Based Error Estimates for Surrogate Models to Accurately Predict Probabilities of Events

In thist study, we develop a procedure to utilize error estimates for samples of a surrogate model to compute robust upper and lower bounds on estimates of probabilities of events. We show that these error estimates can also be used in an adaptive algorithm to simultaneously reduce the computational cost and increase the accuracy in estimating probabilities of events using computationally expensive high-fidelity models. Specifically, we introduce the notion of reliability of a sample of a surrogate model, and we prove that utilizing the surrogate model for the reliable samples and the high-fidelity model for the unreliable samples gives precisely the same estimate of the probability of the output event as would be obtained by evaluation of the original model for each sample. The adaptive algorithm uses the additional evaluations of the high-fidelity model for the unreliable samples to locally improve the surrogate model near the limit state, which significantly reduces the number of high-fidelity model evaluations as the limit state is resolved. Numerical results based on a recently developed adjoint-based approach for estimating the error in samples of a surrogate are provided to demonstrate (1) the robustness of the bounds on the probability of an event, and (2) that the adaptive enhancement algorithm provides a more accurate estimate of the probability of the QoI event than standard response surface approximation methods at a lower computational cost.

97 MATHEMATICS AND COMPUTING↗

Residual a posteriori error estimation of a mimetic/virtual element method

A posteriori error estimation and adaptivity are very useful in the context of the mimetic finite difference method due to the flexibility of the meshes to which this family of numerical schemes can be applied. Nevertheless, developing error estimators for mimetic methods is not a straightforward task due to the lack of knowledge of the basis functions. This issue is tackled by the virtual element method recently introduced in [4], which can be interpreted as a Galerkin reformulation of the mimetic finite difference method. In the new virtual element setting, we develop a residual based a posteriori error estimator that immediately applies to its mimetic counterpart. For such estimator we prove the reliability and we show the numerical performance when it is combined with an adaptive strategy for the mesh refinement. For the lowest-regular approximation we also developed an hp-adaptive strategy based on the comparison between the numerical solution on a base mesh and on a reference mesh.

a posteriori error estimation↗

Measurement Error Variance Estimation in Gamma-Spectroscopy Data using FRAM

The FRAM gamma-ray isotopic analysis code has recently been applied to four Pu data sets and four U data sets, each with relatively well-characterized standard items, in order to estimate the variances of random errors and of item-specific systematic errors. Assay results are available for Pu238, Pu239, Pu240, Pu241, Pu242 (operator entered, not independently measured), Am241, Specific Power, and Pu240eff. For the four U data sets, results are available for the measurands U234, U235, U236 (operator entered, not independently measured), and U238. For example, in Pu data set 1, there are 33 standard reference Pu items, which have well-known nominal/true values (except for a few items). FRAM was used to make approximately 15 repeat measurements for each of the 33 items, so empirical standard deviations can be calculated. In addition, FRAM internally estimates its random error variance using propagation of variance. This paper applies analysis of variance (ANOVA) to separately estimate the repeatability standard deviation and the standard deviation of the item-specific biases δ s in each of the 8 data sets.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

EFCOG Human Performance Improvement Task Group: Task 20-2, Asking Better Error Precursor Questions for Effective Job Planning, Pre-Job Briefs, and Event Investigations

The second principle of human performance states: “error-likely situations are predictable, manageable, and preventable.” An error-likely situation comes into play when task-related factors exceed the capabilities of the individual, creating a mismatch at the point when the individual is “touching” either the physical or the paper plant. The simple presence of adverse conditions cannot be error-likely unless a specific action is to occur within that set of adverse conditions.

99 GENERAL AND MISCELLANEOUS↗

Implementation Guide for Minimum Required Error Codes in Electric Vehicle Charging Infrastructure

With the growing adoption of Electric Vehicles (EVs), there is an increasing need for a reliable EV charging infrastructure. To help meet this need, the report “Recommendations for Minimum Required Error Codes for Electric Vehicle Charging Infrastructure,” recommends a set of minimum required error codes (MRECs) and their functional and responsibility classification. Charger manufacturers, charging station operators, EV manufacturers, and other stakeholders in the North American market are encouraged to uniformly adopt the MRECs to enhance EV charging error reporting, interpretation, and diagnostics. This document serves as a guide to enable uniform implementation of the MRECs using the Open Charge Point Protocol (OCPP).

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Characterizing the Impact of Heliostat Size, Focus Method, and Optical Error on Concentrating Solar Tower Systems

Concentrating Solar Power (CSP) tower systems use heliostat fields to direct solar energy to a central receiver. The efficiency of the heliostat field is crucial for achieving thermal generation targets and is also the largest cost component, making up 30-40% of total project costs. Developers face a tradeoff: reducing heliostat costs may decrease optical performance and increase land use, while improving performance could raise manufacturing costs (through higher precision). The optimal design depends on land, labor, and manufacturing costs. Additionally, inherent performance limitations exist - optical errors result in larger solar images as heliostats move farther from the receiver, increasing spillage and attenuation losses. Ultimately, there exists a point where receiver design power can no longer be achieved at design conditions for a given solar field area. This point depends on key heliostat field design parameters including field layout, heliostats size, focus method, and heliostat optical error. In this work, we explore and characterize the performance trade-offs between heliostat size, focus method, and optical error using Monte Carlo ray-tracing simulations using NREL's high performance computing resources. The goal of this fundamental investigation is to understand practical heliostat design performance impacts that can be used to produce more cost-effective heliostat fields while still achieving plant thermal generation targets.

14 SOLAR ENERGY↗

Evaluation of the Four-Dimensional Ensemble-Variational Hybrid Data Assimilation with Self-Consistent Regional Background Error Covariance for Improved Hurricane Intensity Forecasts

The feasibility of a hurricane initialization framework based on the Gridpoint Statistical Interpolation (GSI)-based four-dimensional ensemble-variational (GSI-4DEnVar) hybrid data assimilation system for the Hurricane Weather Research and Forecasting model (HWRF) model is evaluated in this study. The system considers the temporal evolution of error covariances via the use of four-dimensional ensemble perturbations that are provided by high-resolution, self-consistent HWRF ensemble forecasts. It is different from the configuration of the GSI-based three-dimensional ensemble-variational (GSI-3DEnVar) hybrid data assimilation system, similar to that used in the operational HWRF, which employs background error covariances provided by coarser-resolution global ensembles from the National Centers for Environmental Prediction (NCEP) Global Forecast System (GFS) ensemble Kalman filtering data assimilation system. In addition, our proposed initialization framework discards the empirical intensity correction in the vortex initialization package that is employed by the GSI-3DEnVar initialization framework in operational HWRF. Data assimilation and numerical simulation experiments for Hurricanes Joaquin (2015), Patricia (2015), and Matthew (2016) are conducted during their intensity changes. The impacts of two initialization frameworks on the HWRF analyses and forecasts are compared. It is found that GSI-4DEnVar leads to a reduction in track, minimum sea level pressure (MSLP), and maximum surface wind (MSW) forecast errors in all of the HWRF simulations, compared with the GSI-3DEnVar initialization framework. With assimilating high-resolution observations within the hurricane inner-core region, GSI-4DEnVar can produce the initial hurricane intensity reasonably well without the empirical vortex intensity correction. Further diagnoses with Hurricane Joaquin indicate that GSI-4DEnVar can significantly alleviate the imbalances in the initial conditions and enhance the performance of the data assimilation and subsequent hurricane intensity and precipitation forecasts

54 ENVIRONMENTAL SCIENCES↗