Search NASA⌕ Search

SEARCH · Search NASA

Results for “experimental setup”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 721 records · Page 40

Measurements of thermophysical properties of solids at the Institute VINČA

This paper presents the Metrological Laboratory for Thermophysical Quantities (MLTV) and its actual measurement possibilities. The MLTV is located in the Department of Thermal Engineering and Energy of the Institute of Nuclear Sciences VINČA in Serbia. It was founded in 1963, accredited by the National Accreditation Body in 2007 and became the national designated laboratory for thermophysical quantities and received the status of a EURAMET Associate Member in 2015. Today, the laboratory develops, maintains and disseminates traceability of different national standards, such as those for thermal conductivity of insulations and poorly conductive solid materials from 250 K to 350 K, thermal diffusivity of a large variety of solid materials from 200 K to 1450 K and specific heat and specific electrical resistivity from 250 K to 2400 K of electroconductive solid materials. Total hemispherical and spectral normal emissivity from 1200 K to 2400 K of electroconductive solid materials are also measured in the MLTV. The methods and experimental setups for the realization and measurement of all of these standards and quantities are described with corresponding examples.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Status and results from the decay spectroscopy project EURICA (Euroball-RIKEN cluster array)

β- and isomer-decay spectroscopy are sensitive probes of nuclear structure, and are often the only techniques capable of providing data for exotic nuclei that are produced with very low rates. Decay properties of exotic nuclei are also essential to model astrophysical events responsible for the evolution of the universe such as the rp- and r-processes. The EURICA project (EUROBALL RIKEN Cluster Array) has been launched in 2012 with the goal of performing spectroscopy of very exotic nuclei. Since 2012, five experimental campaigns have been successfully completed using fragmentation of {sup 124}Xe beam and in-flight-fission of {sup 238}U beam. In these proceedings we will introduce the experimental setup and highlight some key recent results around {sup 78}Ni, {sup 132}Sn, and {sup 110}Zn published during 2014 and 2015.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Overview of in-beam gamma-ray spectroscopy at the RIBF

At the Radioactive Isotope Beam Factory stable primary beams are accelerated up to 345 MeV/u and incident on a primary target to produce cocktail secondary beams with the fragment separator BigRIPS ranging from the lightest nuclei up to the lead region. For in-beam γ-ray spectroscopy, the secondary beams impinge on a reaction target at energies between 100 and 300 MeV/u. Reaction residues are identified with the ZeroDegree spectrometer and γ-rays detected with the NaI(Tl) based DALI2 array. This conference paper outlines the experimental setup and presents recent exemplary results.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

In vivo measurement of mechanical properties of human long bone by using sonic sound

Vibration analysis has evaluated as non-invasive techniques for the in vivo assessment of bone mechanical properties. The relation between the resonant frequencies, long bone geometry and mechanical properties can be obtained by vibration analysis. In vivo measurements were performed on human ulna as a simple beam model with an experimental technique and associated apparatus. The resonant frequency of the ulna was obtained by Fast Fourier Transformation (FFT) analysis of the vibration response of piezoelectric accelerometer. Both elastic modulus and speed of the sound were inferred from the resonant frequency. Measurement error in the improved experimental setup was comparable with the previous work. The in vivo determination of bone elastic response has potential value in screening programs for metabolic bone disease, early detection of osteoporosis and evaluation of skeletal effects of various therapeutic modalities.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

High brightness gamma-ray production at Fermilab Accelerator Science and Technology (FAST) facility

Electron beams with energies of the order of a few 100's of MeV and low transverse emittance, in combination with powerful infrared lasers, allow for the production of high quality gamma rays through Inverse Compton Scattering (ICS). At Fermilab Accelerator Science and Technology (FAST) facility, a 300 MeV beam will be used to generate gamma rays with maximum photon energies of up to ~1.5 MeV and brightness of the order of 10 21 photons/[s-(mm-mrad) 2- 0.1%BW]. Due to the low electron-beam transverse emittance, the relative bandwidth of the scattered radiation is expected to be ≤ 1%. A key challenge toward the production of high radiation dose and brightness is to enhance the energy of the infrared 3 ps laser pulses to the joule level. Finally, in this contribution, we present the plans for the experimental setup, along with comprehensive numerical simulations of the ICS process.

43 PARTICLE ACCELERATORS↗

Jumping-droplet electronics hot-spot cooling

Demand for enhanced cooling technologies within various commercial and consumer applications has increased in recent decades due to electronic devices becoming more energy dense. This study demonstrates jumping-droplet based electric-field-enhanced (EFE) condensation as a potential method to achieve active hot spot cooling in electronic devices. To test the viability of EFE condensation, we developed an experimental setup to remove heat via droplet evaporation from single and multiple high power gallium nitride (GaN) transistors acting as local hot spots (4.6 mm x 2.6 mm). An externally powered circuit was developed to direct jumping droplets from a copper oxide (CuO) nanostructured superhydrophobic surface to the transistor hot spots by applying electric fields between the condensing surface and the transistor. Heat transfer measurements were performed in ambient air (22-25°C air temperature, 20-45% relative humidity) to determine the effect of gap spacing (2-4 mm), electric field (50-250 V/cm), and heat flux (demonstrated to 13 W/cm 2 ). EFE condensation was shown to enhance the heat transfer from the local hot spot by ≈ 200% compared to cooling without jumping and by 20% compared to non-EFE jumping. Dynamic switching of the electric field for a two-GaN system reveals the potential for active cooling of mobile hot spots. The opportunity for further cooling enhancement by the removal of non-condensable gases promises hot spot heat dissipation rates approaching 120 W/cm 2 . Finally, this work provides a framework for the development of active jumping droplet based vapor chambers and heat pipes capable of spatial and temporal thermal dissipation control.

36 MATERIALS SCIENCE↗

Average neutron time-of-flight instrument response function inferred from single D-T neutron events within a plastic scintillator

The apparent ion temperature and neutron-reaction history are important characteristics of a fusion plasma. Extracting these quantities from a measured neutron-time-of-flight signal requires accurate knowledge of the instrument response function (IRF). This paper describes a novel method for obtaining the IRF directly for single DT neutron interactions by utilizing n-alpha coincidence. The t(d,α)n nuclear reaction was produced at Sandia National Laboratories’ Ion Beam Laboratory using a 300 keV Cockcroft-Walton generator to accelerate a 2.5 μA beam of 175 keV D + ions into a stationary ErT 2 target. The average neutron IRF was calculated by taking a time-corrected average of individual neutron events within an EJ-228 plastic scintillator. The scintillator was coupled to two independent photo-multiplier tubes operated in the current mode: a Hamamatsu 5946 mod-5 and a Photek PMT240. Finally, the experimental setup and results will be discussed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Noise mitigation methods for ion detectors operating with a direct view of high temperature plasmas

In this work, we have developed an ion current measurement instrument with a direct view of a plasma that reduces the particle and radiation-induced noise current it detects by over three orders of magnitude, from tens of microamps to tens of nanoamps. This is accomplished using electric fields, magnetic fields, and physical shielding that limit the flux of particles and radiation into the instrument and suppress the secondary electrons produced within it by particle and radiation impact. Operation of this detector in various configurations, without an ion beam, has allowed identification of the sources of noise current. In our experimental setup, the largest noise contributors were found to be plasma ions and photoelectric emission due to UV radiation.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Reconstruction and analysis of exploding wire particle trajectories via automatic calibration of stereo images

Quantitative understanding of the physics of dust or granular matter transport significantly impacts several aspects of burning plasma science and technology. Here, this work takes machine vision techniques popular in robotics and self-driving cars and applies them to identification and analysis of microparticles generated from exploding wires. Using only the image frames and knowledge of the intrinsic properties of the cameras, a Python code was written to identify the particles, automatically calibrate the relative image positions, and extract trajectory data. After identifying approximately 50 particles based on the timing of secondary particle explosions, the eight point and random sample consensus algorithms were used to determine the geometric correlation between the cameras. Over 100 particle matches were found between the two camera views. These correlated trajectories were used in subsequent 3D track reconstruction and analysis of the physics behind the particle motion. The 3D reconstruction resulted in accurate positioning of the particles with respect to the experimental setup. The particle motion was consistent with the effects of a 1 g gravitational field modified by drag forces. Lastly, the methods and analyses presented here can be used in many facets of high temperature plasma diagnostics.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Note: Plasma optical emission spectroscopy for water vapor quantification and detection during vacuum drying process

In this work, a methodology involving plasma optical emission spectroscopy driven by a direct current (dc) plasma source is developed to quantify water vapor concentration in a gaseous stream. The experimental setup consists of a dc driven low-pressure plasma cell in which the emission from the plasma discharge is measured by using an optical emission spectrometer. The emission from Hα at 656.2 nm—the first transition in the Balmer series, was found to be the most sensitive to the water vapor concentration in the gas stream. Consistent linear trends of the emission signals with respect to variation in concentration of water are observed for multiple combinations of operating parameters. This method has been applied to a vacuum drying process of a mock nuclear fuel assembly to quantify the concentration of water vapor during the drying process.

47 OTHER INSTRUMENTATION↗

Phonon relaxation time reconstruction from transient thermal grating experiments and comparison with density functional theory predictions

Phonon relaxation time and free path distributions are reconstructed from experimental measurements on a two-dimensional transient thermal grating and compared with density functional theory (DFT) results for silicon. The reconstruction is performed using the inverse problem formulation of Forghani et al. [Phys. Rev. B 94, 155439 (2016)]. The discrepancies observed between reconstructed and DFT results are analyzed in terms of the ability of each set of data to reproduce the experimental temperature relaxation profiles; the reconstructed data are found to predict temperature profiles in closer agreement with the experimental data than the DFT results, possibly due to discrepancies between the actual material and the idealized model studied in the DFT calculations. The reconstructed phonon properties accurately predict temperature relaxation profiles at grating length scales smaller than those spanned by the experimental data. Finally, this is a very important feature since in a variety of experimental setups, including the one providing the data in the present study, measurements are not available at all scales spanned by the material free paths.

42 ENGINEERING↗

New dynamic diamond anvil cells for tera-pascal per second fast compression x-ray diffraction experiments

Fast compression experiments performed using dynamic diamond anvil cells (dDACs) employing piezoactuators offer the opportunity to study compression-rate dependent phenomena. In this paper, we describe an experimental setup which allows us to perform time-resolved x-ray diffraction during the fast compression of materials using improved dDACs. The combination of the high flux available using a 25.6 keV x-ray beam focused with a linear array of compound refractive lenses and the two fast GaAs LAMBDA detectors available at the Extreme Conditions Beamline (P02.2) at PETRA III enables the collection of x-ray diffraction patterns at an effective repetition rate of up to 4 kHz. Compression rates of up to 160 TPa/s have been achieved during the compression of gold in a 2.5 ms fast compression using improved dDAC configurations with more powerful piezoactuators. The application of this setup to low-Z compounds at lower compression rates is described, and the high temporal resolution of the setup is demonstrated. The possibility of applying finely tuned pressure profiles opens opportunities for future research, such as using oscillations of the piezoactuator to mimic propagation of seismic waves in the Earth.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Probing the electronic structure of graphene near and far from the Fermi level via planar tunneling spectroscopy

Scanning tunneling spectroscopy (STS) has yielded significant insight into the electronic structure of graphene and other two-dimensional (2D) materials. STS directly measures a fundamental and directly calculable quantity: single particle density of states (SPDOS). Due to experimental setup limitations, however, STS has been unable to explore 2D materials in ultrahigh magnetic fields where electron-electron interactions can drastically change the SPDOS. Recent developments in the assembly of heterostructures composed of graphene and hexagonal boron nitride have enabled a device-based alternative to potentially overcome these roadblocks. Thus far, however, these nascent efforts are incomplete in analyzing and understanding tunneling spectra and have yet to explore graphene at high magnetic fields. Here, we report an experiment at magnetic fields up to 18 T, which uses graphene tunneling field effect transistors (TFETs) to establish a clear benchmark for the measurement and analysis of graphene planar tunneling spectroscopy. We acquire gate tunable tunneling spectra of graphene and then use these data and electrostatic arguments to develop a systematic analysis scheme. This analysis reveals that TFET devices directly probe electronic structure features near and far from the Fermi level. In particular, our study yields identification of the Dirac point and numerous Landau levels as they fill and empty with charge via the application of a gate voltage. Our work demonstrates that TFET devices are a viable platform for directly probing the electronic structure of graphene and other 2D materials in high magnetic fields, where exotic electronic states emerge.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

A multi-wavelength streaked optical pyrometer for dynamic shock compression measurements above 2500 K

This work presents a concept and implementation of a calibrated streaked spectral pyrometer (SSP) temperature diagnostic used in dynamically driven shock experiments on a two-stage gas gun. This system relies upon measuring the total system response using a tunable monochromator, a NIST-traceable calibrated power meter, and a SSP. The diagnostic performance is validated against previously measured temperatures of shock driven z-cut quartz at 99 GPa and 93 GPa. The results are found to agree with the literature to within 5% and are discussed in this manuscript. The experimental setup utilizes measurements from multiple SSP systems per sample, providing several independent measurements and substantially increasing confidence in the extrapolated shock driven sample temperature.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Design and implementation of a J -coupled spectrometer for multidimensional structure and relaxation detection at low magnetic fields

In recent years, it has been realized that low and ultra-low field (mT-nT magnetic field range) nuclear magnetic resonance (NMR) spectroscopy can be used for molecular structural analysis. However, spectra are often hindered by lengthy acquisition times or require large sample volumes and high concentrations. Here, we report a low field (50 µT) instrument that employs a linear actuator to shuttle samples between a 1 T prepolarization field and a solenoid detector in a laboratory setting. The current experimental setup is benchmarked using water and 13 C-methanol with a single scan detection limit of 2x10 20 spins (3 μL, 55 M H 2 O) and detection of 2.9x10 19 (200 μL, 617 mM 13 C-methanol) spins with signal averaging. The system has a dynamic range of >3 orders of magnitude. Investigations of room-temperature relaxation dynamics of 13Cmethanol show that sample dilution can be used in lieu of sample heating to acquire spectra with linewidths comparable to high-temperature spectra. These results indicate that the T 1 and T 2 mechanisms are governed by both the proton exchange rate and the dissolved oxygen in the sample. Finally, a 2D correlation spectroscopy (COSY) experiment is reported, performed in the strong coupling regime that resolves the multiple resonances associated with the heteronuclear Jcoupling. The spectrum was collected using 10 times less sample and in less than half the time from previous reports in the strong coupling limit.

47 OTHER INSTRUMENTATION↗

Piezoresponse amplitude and phase quantified for electromechanical characterization

Piezoresponse force microscopy (PFM) is a powerful characterization technique to readily image and manipulate the ferroelectric domains. PFM gives an insight into the strength of local piezoelectric coupling and polarization direction through PFM amplitude and phase, respectively. Converting measured arbitrary units into units of effective piezoelectric constant remains a challenge, and insufficient methods are often used. While most quantification efforts have been spent on quantifying the PFM amplitude signal, little attention has been given to the PFM phase, which is often arbitrarily adjusted to fit expectations. This is problematic when investigating materials with unknown or negative sign of the probed effective electrostrictive coefficient or strong frequency dispersion of electromechanical responses, because assumptions about the PFM phase cannot be reliably made. The PFM phase can, however, provide important information on the polarization orientation and the sign of the effective electrostrictive coefficient probed by PFM. Most notably, the orientation of the PFM hysteresis loop is determined by the PFM phase. Moreover, when presenting PFM data as a combined signal, the resulting response can be artificially lowered or asymmetric if the phase data have not been correctly processed. Here, we explain the PFM amplitude quantification process and demonstrate a path to identify the phase offset required to extract correct meaning from the PFM phase data. We explore different sources of phase offsets including the experimental setup, instrumental contributions, and data analysis. We discuss the physical working principles of PFM and develop a strategy to extract physical meaning from the PFM amplitude and phase.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Toward 3D data visualization using virtual reality tools

Virtual Reality (VR) offers the opportunity to display data, instrumentation, and experimental setups in three dimensions and gives the user the ability to interact with the objects. This technology moves visualization beyond two-dimensional projections on a flat screen with a fixed field of view in which a keyboard or another similar controller is needed to change the view. Advances in both hardware and software for VR make it possible for the non-expert to develop visualization tools for scientific applications both for viewing and for sharing data or diagnostic hardware between users in three dimensions. Furthermore, this manuscript describes application development using two VR software tools, Unity gaming engine and A-frame, for visualizing data and high energy physics targets.

47 OTHER INSTRUMENTATION↗

Characterizing x-ray transmission through filters used in high energy density physics diagnostics

We report on the design and implementation of a new system used to characterize the energy-dependent x-ray transmission curve, Θ(E), through filters used in high-energy density physics diagnostics. Using an Amptek X-123-CdTe x-ray spectrometer together with a partially depleted silicon surface barrier detector, both the energy spectrum and total emission of an x-ray source have been accurately measured. By coupling these detectors with a custom PROTO-XRD x-ray source with interchangeable cathodes, accurate characterizations of Θ(E) for filters of varying materials and thicknesses have been obtained. The validity of the technique has been confirmed by accurately reproducing areal densities for high-purity filters with known x-ray transmission properties. In this paper, the experimental setup is described and the results of absorption calibrations performed on a variety of different filters are presented.

47 OTHER INSTRUMENTATION↗