Search NASA⌕ Search

SEARCH · Search NASA

Results for “filter methods”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 721 records · Page 40

GAINN: The Galaxy Assembly and Interaction Neural Networks for High-redshift JWST Observations

We present the Galaxy Assembly and Interaction Neural Networks (Gainn), a series of artificial neural networks for predicting the redshift, stellar mass, halo mass, and mass-weighted age of simulated galaxies based on James Webb Space Telescope (JWST) photometry. Our goal is to determine the best neural network for predicting these variables at 11 < z < 15. The parameters of the optimal neural network can then be used to estimate these variables for real, observed galaxies. The inputs of the neural networks are JWST filter magnitudes of a subset of five broadband filters (F150W, F200W, F277W, F356W, and F444W) and two medium-band filters (F162M and F182M). We compare the performance of the neural networks using different combinations of these filters, as well as different activation functions and numbers of layers. The best neural network predicted redshift with a normalized rms error of $0.010^{+0.003}_{-0.001}$, stellar mass with rms = $0.089^{+0.044}_{-0.022}$, halo mass with a mean-squared error of $0.022^{+0.014}_{-0.008}$, and mass-weighted age with rms = $12.466^{+5.065}_{-2.408}$. We also test the performance of Gainn on real data from MACS0647JD, an object observed by JWST. Predictions from Gainn for the first projection of the object (JD1) have normalized bias $\langle$Δz$\rangle$ < 0.00228, which is significantly smaller than found with template-fitting methods. We find that the optimal filter combination is F277W, F356W, F162M, and F200W when considering both theoretical accuracy and observational resources from JWST.

97 MATHEMATICS AND COMPUTING↗

A dynamic data-driven method for dealing with model structural error in soil moisture data assimilation

Attributing to the flexibility in considering various types of observation error and model error, data assimilation has been increasingly applied to dynamically improve soil moisture modeling in many hydrological practices. However, accurate characterization of model error, especially the part caused by defective model structure, presents a significant challenge to the successful implementation of data assimilation. Model structural error has received limited attention relative to parameter and input errors, mainly due to our poor understanding of structural inadequacy and the difficulties in parameterizing structural error. In this paper, we present a dynamic data-driven approach to estimate the model structural error in soil moisture data assimilation without the need for identifying error generation mechanism or specifying particular form for the error model. The error model is based on the Gaussian process regression and then integrated into the ensemble Kalman filter (EnKF) to form a hybrid method for dealing with multi-source model errors. Two variants of the hybrid method in terms of two different error correction manners are proposed. The effectiveness of the proposed method is tested through a suit of synthetic cases and a real-world case. Results demonstrate the potential of the proposed hybrid method for estimating model structural error and providing improved model predictions. Compared to the traditional EnKF without explicitly considering the model structural error, parameter compensation issue is obviously reduced and soil moisture retrieval is substantially improved.

54 ENVIRONMENTAL SCIENCES↗

Photonic crystal ring resonator based optical filters for photonic integrated circuits

In this paper, a two Dimensional (2D) Photonic Crystal Ring Resonator (PCRR) based optical Filters namely Add Drop Filter, Bandpass Filter, and Bandstop Filter are designed for Photonic Integrated Circuits (PICs). The normalized output response of the filters is obtained using 2D Finite Difference Time Domain (FDTD) method and the band diagram of periodic and non-periodic structure is attained by Plane Wave Expansion (PWE) method. The size of the device is minimized from a scale of few tens of millimeters to the order of micrometers. The overall size of the filters is around 11.4 μm × 11.4 μm which is highly suitable of photonic integrated circuits.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Calibrating Parameters of Power System Stability Models Using Advanced Ensemble Kalman Filter

With the ever increasing penetration of renewable energy, smart loads, energy storage, and new market behavior, today's power grid becomes more dynamic and stochastic, which may invalidate traditional study assumptions and pose great operational challenges. Thus, it is of critical importance to maintain good-quality models for secure and economic planning and real-time operation. Following the 1996 Western Systems Coordinating Council (WSCC) system blackout, North American Electric Reliability Corporation (NERC) and Western Electricity Coordinating Council (WECC) in North America enforced a number of policies and standards to guide the power industry to periodically validate power grid models and calibrate poor parameters with the goal of building sufficient confidence in model quality. The PMU-based approach using online measurements without interfering with the operation of generators provides a low-cost alternative to meet NERC standards. This paper presents an innovative procedure and tool suites to validate and calibrate models based on a trajectory sensitivity analysis method and an advanced ensemble Kalman filter algorithm. The developed prototype demonstrates excellent performance in identifying and calibrating bad parameters of a realistic hydro power plant against multiple system events.

Huang, Renke (ORCID:0000000230947073)↗

Application of Noise Cancelling and Damage Detection Algorithms in NDE of Concrete Bridge Decks Using Impact Signals

Delamination is a commonly observed distress in concrete bridge decks. Among all the delamination detection methods, acoustic methods have the advantages of being fast and inexpensive. In traditional acoustic inspection methods, the inspector drags a chain along or hammers on the bridge deck and detects delamination from the 'hollowness' of the sounds. The signals are often contaminated by ambient traffic noise and the detection of delamination is highly subjective. This paper describes the performance of an impact-bases acoustic NDE method where the traffic noise was filtered by employing a noise cancelling algorithm and where subjectivity was eliminated by introducing feature extraction and pattern recognition algorithms. Different algorithms were compared and the best one was selected in each category. The comparison showed that the modified independent component analysis (ICA) algorithm was most effective in cancelling the traffic noise and features consisting of mel-frequency cepstral coefficients (MFCCs) had the best performance in terms of repeatability and separabillty. The condition of the bridge deck was then detected by a radial basis function (RBF) neural network. The performance of the system was evaluated using both experimental and field data. The results show that the selected algorithms increase the noise robustness of acoustic methods and perform satisfactorily if the training data is representative.

42 ENGINEERING↗

Response of consumer and research grade indoor air quality monitors to residential sources of fine particles

The ability to inexpensively monitor PM2.5 to identify sources and enable controls would advance residential indoor air quality (IAQ) management. Consumer IAQ monitors incorporating low-cost optical particle sensors and connections with smart home platforms could provide this service if they reliably detect PM 2.5 in homes. In this study, particles from typical residential sources were generated in a 120 m 3 laboratory and time-concentration profiles were measured with 7 consumer monitors (2-3 units each), 2 research monitors (Thermo pDR-1500, MetOne BT-645), a Grimm Mini Wide-Range Aerosol Spectrometer (GRM), and a Tapered Element Oscillating Microbalance with Filter Dynamic Measurement System (FDMS), a Federal Equivalent Method for PM2.5. Sources included recreational combustion (candles, cigarettes, incense), cooking activities, an unfiltered ultrasonic humidifier, and dust. FDMS measurements, filter samples, and known densities were used to adjust the GRM to obtain time-resolved mass concentrations. Data from the research monitors and 4 of the consumer monitors—AirBeam, AirVisual, Foobot, Purple Air—were time correlated and within a factor of 2 of the estimated mass concentrations for most sources. In conclusion, all 7 of the consumer and both research monitors substantially under-reported or missed events for which the emitted mass was comprised of particles smaller than 0.3 μm diameter.

47 OTHER INSTRUMENTATION↗

SU-E-T-145: Beam Characteristics of Flattening Filter Free Beams Including Low Dose Rate Setting

Purpose: In commissioning of volumetric modulated arc therapy (VMAT), it is necessary to evaluate the beam characteristics of various dose rate settings with potential to use. The aim of this study is to evaluate the beam characteristics of flattened and flattening filter free (FFF) including low dose rate setting. Methods: We used a Varian TrueBeam with Millennium 120 MLC. Both 6 and 10 MV beams with or without flattening filter were used for this study. To evaluate low-dose rate FFF beams, specially-designed leaf sequence files control out-of-field MLC leaf pair at constant dose rate ranging from 80 to 400 MU/min. For dose rate from 80 MU/min to the maximum usable value of all energies, beam output were measured using ionization chamber (CC04, IBA). The ionization chamber was inserted into water equivalent phantom (RT3000-New, R-tech), and the phantom was set with SAD of 100cm. The beam profiles were performed using the 2D diode array (Profiler2, Sun Nuclear). The SSD was set to 90cm and a combined 30cmx30cmx9cm phantom which consisted of solid water slabs was put on the device. All measurement were made using 100MU irradiation for 10cmx10cm jaw-defined field size with a gantry angle of 0°. Results: In all energies, the dose rate dependences with beam output and variation coefficient were within 0.2% and 0.07%, respectively. The flatness and symmetry exhibited small variations (flatness ≤0.1 point and symmetry≤0.3 point at absolute difference). Conclusion: We had studied the characteristics of flattened and FFF beam over the 80 MU/min. Our results indicated that the beam output and profiles of FFF of TrueBeam linac were highly stable at low dose rate setting.

60 APPLIED LIFE SCIENCES↗

IPET and FETR: Experimental Approach for Studying Molecular Structure Dynamics by Cryo-Electron Tomography of a Single-Molecule Structure

The dynamic personalities and structural heterogeneity of proteins are essential for proper functioning. Structural determination of dynamic/heterogeneous proteins is limited by conventional approaches of X-ray and electron microscopy (EM) of single-particle reconstruction that require an average from thousands to millions different molecules. Cryo-electron tomography (cryoET) is an approach to determine three-dimensional (3D) reconstruction of a single and unique biological object such as bacteria and cells, by imaging the object from a series of tilting angles. However, cconventional reconstruction methods use large-size whole-micrographs that are limited by reconstruction resolution (lower than 20 Å), especially for small and low-symmetric molecule (,400 kDa). In this study, we demonstrated the adverse effects from image distortion and the measuring tilt-errors (including tilt-axis and tilt-angle errors) both play a major role in limiting the reconstruction resolution. Therefore, we developed a ‘‘focused electron tomography reconstruction’’ (FETR) algorithm to improve the resolution by decreasing the reconstructing image size so that it contains only a single-instance protein. FETR can tolerate certain levels of image-distortion and measuring tilt-errors, and can also precisely determine the translational parameters via an iterative refinement process that contains a series of automatically generated dynamic filters and masks. To describe this method, a set of simulated cryoET images was employed; to validate this approach, the real experimental images from negative-staining and cryoET were used. Since this approach can obtain the structure of a single-instance molecule/particle, we named it individual-particle electron tomography (IPET) as a new robust strategy/approach that does not require a pre-given initial model, class averaging of multiple molecules or an extended ordered lattice, but can tolerate small tilt-errors for high-resolution single ‘‘snapshot’’ molecule structure determination. Thus, FETR/IPET provides a completely new opportunity for a single-molecule structure determination, and could be used to study the dynamic character and equilibrium fluctuation of macromolecules.

59 BASIC BIOLOGICAL SCIENCES↗

Real-time ensemble microalgae growth forecasting with data assimilation

Accurate short-range (e.g., 7-day) microalgae growth forecasts will be beneficial for both production and harvesting of microalgae. This study developed an operational microalgae growth forecasting system with ensemble data assimilation (DA). The forecasting system was validated against observed Monoraphidium minutum 26B-AM growth in two outdoor pond cultures located in Mesa, Arizona, U.S. We first examined the relative roles of uncertainty in the meteorological forecast and initial conditions (i.e., algal concentration at the time of forecast) in the microalgae 7-day forecast and found initial conditions dominated the microalgae forecasting skill, suggesting the importance of implementing DA to improve initial condition characterization. To correct the systematic bias in biomass simulations, we developed a particle filter with bias estimation (PFBE) DA method to estimate biases and correct the model forecast. We found the DA forecasting system could improve the 7-day microalgae forecasting skill by about 85% on average compared to model forecasts without DA. These results suggest the potential accuracy of biomass growth forecasts may be sufficient to inform real-time operational decisions, such as harvesting planning, for commercial-scale microalgae production.

59 BASIC BIOLOGICAL SCIENCES↗

A fast mollified impulse method for biomolecular atomistic simulations

Classical integration methods for molecular dynamics are inherently limited due to resonance phenomena occurring at certain time-step sizes. The mollified impulse method can partially avoid this problem by using appropriate filters based on averaging or projection techniques. However, existing filters are computationally expensive and tedious in implementation since they require either analytical Hessians or they need to solve nonlinear systems from constraints. In this work we follow a different approach based on corotation for the construction of a new filter for (flexible) biomolecular simulations. The main advantages of the proposed filter are its excellent stability properties and ease of implementation in standard softwares without Hessians or solving constraint systems. By simulating multiple realistic examples such as peptide, protein, ice equilibrium and ice–ice friction, the new filter is shown to speed up the computations of long-range interactions by approximately 20%. The proposed filtered integrators allow step sizes as large as 10 fs while keeping the energy drift less than 1% on a 50 ps simulation.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Efficacy of fixed filtration for rapid kVp-switching dual energy x-ray systems

Purpose: Dose efficiency of dual kVp imaging can be improved if the two beams are filtered to remove photons in the common part of their spectra, thereby increasing spectral separation. While there are a number of advantages to rapid kVp-switching for dual energy, it may not be feasible to have two different filters for the two spectra. Therefore, the authors are interested in whether a fixed added filter can improve the dose efficiency of kVp-switching dual energy x-ray systems. Methods: The authors hypothesized that a K-edge filter would provide the energy selectivity needed to remove overlap of the spectra and hence increase the precision of material separation at constant dose. Preliminary simulations were done using calcium and water basis materials and 80 and 140 kVp x-ray spectra. Precision of the decomposition was evaluated based on the propagation of the Poisson noise through the decomposition function. Considering availability and cost, the authors chose a commercial Gd{sub 2}O{sub 2}S screen as the filter for their experimental validation. Experiments were conducted on a table-top system using a phantom with various thicknesses of acrylic and copper and 70 and 125 kVp x-ray spectra. The authors kept the phantom exposure roughly constant with and without filtration by adjusting the tube current. The filtered and unfiltered raw data of both low and high energy were decomposed into basis material and the variance of the decomposition for each thickness pair was calculated. To evaluate the filtration performance, the authors measured the ratio of material decomposition variance with and without filtration. Results: Simulation results show that the ideal filter material depends on the object composition and thickness, and ranges across the lanthanide series, with higher atomic number filters being preferred for more attenuating objects. Variance reduction increases with filter thickness, and substantial reductions (40%) can be achieved with a 2× loss in intensity. The authors’ experimental results validate the simulations, yet were overall slightly worse than expectation. For large objects, conventional (non-K-edge) beam hardening filters perform well. Conclusions: This study demonstrates the potential of fixed K-edge filtration to improve the dose efficiency and material decomposition precision for rapid kVp-switching dual energy systems.

61 RADIATION PROTECTION AND DOSIMETRY↗

Spin-Filtering studies at COSY and AD

An overview on the present understanding of the methods to polarize an antiproton beam is given and the planned measurements on spin filtering at COSY and AD rings with protons and antiprotons are described. The experimental setup which is being prepared for these measurements is described and focus is given on the polarized internal target.

43 PARTICLE ACCELERATORS↗

Spin-polarized, orbital-selected hole gas at the EuO/Pt interface

Using density functional theory, we explore the magnetic behavior of a EuO/Pt heterostructure. The calculations suggest that the heterostructure could be used as a spin filter, as the Schottky barriers in the spin-up and spin-down channels are calculated to be 1.42 and 2.18 eV, respectively. We discover that the interfacial and second layer of EuO, both have a reduced magnetic moment, while the remainder of the oxide maintains bulk magnetization. These first two layers support a localized mid-gap electronic state that protects the remainder of EuO from losing charge into the large work function Pt, which in turn results in the magnetic moment reduction. Our calculations are consistent with recent experimental results of Barbagallo et al. [Phys. Rev. B 84, 075219 (2011)].

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

FIRST THREE-DIMENSIONAL RECONSTRUCTIONS OF CORONAL LOOPS WITH THE STEREO A+B SPACECRAFT. III. INSTANT STEREOSCOPIC TOMOGRAPHY OF ACTIVE REGIONS

Here we develop a novel three-dimensional (3D) reconstruction method of the coronal plasma of an active region by combining stereoscopic triangulation of loops with density and temperature modeling of coronal loops with a filling factor equivalent to tomographic volume rendering. Because this method requires only a stereoscopic image pair in multiple temperature filters, which are sampled within {approx}1 minute with the recent STEREO/EUVI instrument, this method is about four orders of magnitude faster than conventional solar rotation-based tomography. We reconstruct the 3D density and temperature distribution of active region NOAA 10955 by stereoscopic triangulation of 70 loops, which are used as a skeleton for a 3D field interpolation of some 7000 loop components, leading to a 3D model that reproduces the observed fluxes in each stereoscopic image pair with an accuracy of a few percents (of the average flux) in each pixel. With the stereoscopic tomography we infer also a differential emission measure distribution over the entire temperature range of T {approx} 10{sup 4}-10{sup 7}, with predictions for the transition region and hotter corona in soft X-rays. The tomographic 3D model provides also large statistics of physical parameters. We find that the extreme-ultraviolet loops with apex temperatures of T{sub m} {approx}< 3.0 MK tend to be super-hydrostatic, while hotter loops with T{sub m} {approx} 4-7 MK are near-hydrostatic. The new 3D reconstruction model is fully independent of any magnetic field data and is promising for future tests of theoretical magnetic field models and coronal heating models.

99 GENERAL AND MISCELLANEOUS↗

SU-G-IeP2-08: Investigation On Signal Detectability in Volumetric Cone Beam CT Images with Anatomical Background

Purpose: To investigate the slice direction dependent detectability in cone beam CT images with anatomical background. Methods: We generated 3D anatomical background images using breast anatomy model. To generate 3D breast anatomy, we filtered 3D Gaussian noise with a square root of 1/f{sup 3}, and then assigned the attenuation coefficient of glandular (0.8cm{sup −1}) and adipose (0.46 cm{sup −1}) tissues based on voxel values. Projections were acquired by forward projection, and quantum noise was added to the projection data. The projection data were reconstructed by FDK algorithm. We compared the detectability of a 3 mm spherical signal in the image reconstructed from four different backprojection Methods: Hanning weighted ramp filter with linear interpolation (RECON1), Hanning weighted ramp filter with Fourier interpolation (RECON2), ramp filter with linear interpolation (RECON3), and ramp filter with Fourier interpolation (RECON4), respectively. We computed task SNR of the spherical signal in transverse and longitudinal planes using channelized Hotelling observer with Laguerre-Gauss channels. Results: Transverse plane has similar task SNR values for different backprojection methods, while longitudinal plane has a maximum task SNR value in RECON1. For all backprojection methods, longitudinal plane has higher task SNR than transverse plane. Conclusion: In this work, we investigated detectability for different slice direction in cone beam CT images with anatomical background. Longitudinal plane has a higher task SNR than transverse plane, and backprojection with hanning weighted ramp filter with linear interpolation method (i.e., RECON1) produced the highest task SNR among four different backprojection methods. This research was supported by the MSIP (Ministry of Science, ICT and Future Planning), Korea, under the IT Consilience Creative Programs(IITP-2015-R0346-15-1008) supervised by the IITP (Institute for Information & Communications Technology Promotion), Basic Science Research Program through the National Research Foundation of Korea (NRF) funded by the MSIP (2015R1C1A1A01052268) and framework of international cooperation program managed by NRF (NRF-2015K2A1A2067635).

60 APPLIED LIFE SCIENCES↗

Tuning Luminescent Converters Based on Coumarins and Their Photostability

We have studied the feasibility of using luminophores in the coumarin series in luminescent filters for correcting the spectra of light-emitting diode (LED) light sources. Fine tuning of the emission spectra of luminophores in polymer matrices is achieved by introducing nonionic surfactants into the matrix. We propose a method for estimating the photostability of luminescent filters and we determine the photostability parameters.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Dual resolution cone beam breast CT: A feasibility study

Purpose: In this study, the authors investigated the feasibility of a dual resolution volume-of-interest (VOI) cone beam breast CT technique and compared two implementation approaches in terms of dose saving and scatter reduction. Methods: With this technique, a lead VOI mask with an opening is inserted between the x-ray source and the breast to deliver x-ray exposure to the VOI while blocking x rays outside the VOI. A CCD detector is used to collect the high resolution projection data of the VOI. Low resolution cone beam CT (CBCT) images of the entire breast, acquired with a flat panel (FP) detector, were used to calculate the projection data outside the VOI with the ray-tracing reprojection method. The Feldkamp-Davis-Kress filtered backprojection algorithm was used to reconstruct the dual resolution 3D images. Breast phantoms with 180 {mu}m and smaller microcalcifications (MCs) were imaged with both FP and FP-CCD dual resolution CBCT systems, respectively. Two approaches of implementing the dual resolution technique, breast-centered approach and VOI-centered approach, were investigated and evaluated for dose saving and scatter reduction with Monte Carlo simulation using a GEANT4 package. Results: The results showed that the breast-centered approach saved more breast absorbed dose than did VOI-centered approach with similar scatter reduction. The MCs in fatty breast phantom, which were invisible with FP CBCT scan, became visible with the FP-CCD dual resolution CBCT scan. Conclusions: These results indicate potential improvement of the image quality inside the VOI with reduced breast dose both inside and outside the VOI.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Measurements of electron temperature in high-energy-density plasmas using gated x-ray pinhole imaging

We present measurements of spatially and temporally resolved electron temperature in high-energy-density plasmas using gated x-ray pinhole imagers. A 2D image of bremsstrahlung x-ray self-emission from laser-driven plasma plumes is detected at the same time through two pinholes covered with different filter materials. By comparing the attenuated signal through each filter, a spatially resolved electron temperature as low as 0.1 keV can be estimated. Measurements of the plasma plume taken from different directions indicate that imaging through extended plasmas has a negligible effect on the temperature estimates. Methods for estimating the expected signal, selecting filters, and incorporating the response of the detector are discussed.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗