Search NASA⌕ Search

SEARCH · Search NASA

Results for “focus”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 721 records · Page 40

Radially Focused Eddy Current Sensor for Detection of Longitudinal Flaws in Metallic Tubes

A radially focused eddy current sensor detects longitudinal flaws in a metal tube. A drive coil induces eddy currents within the wall of the metal tube. A pick-up cod is spaced apart from the drive coil along the length of the metal tube. The pick@up coil is positioned with one end thereof lying adjacent the wall of the metal tube such that the pick-up coil's longitudinal axis is perpendicular to the wall of the metal tube. To isolate the pick-up coil from the magnetic flux of the drive coil and the flux from the induced eddy currents. except the eddy currents diverted by a longitudinal flaw. an electrically conducting material high in magnetic permeability surrounds all of the pick-up coil except its one end that is adjacent the walls of the metal tube. The electrically conducting material can extend into and through the drive coil in a coaxial relationship therewith.

Wincheski, Russell A.↗

Application Focused Schlieren to Nozzle Ejector Flowfields

The motivation of the testing was to reduce noise generated by eddy Mach wave emission via enhanced mixing in the jet plume. This was to be accomplished through the use of an ejector shroud, which would bring in cooler ambient fluid to mix with the hotter jet flow. In addition, the contour of the mixer, with its chutes and lobes, would accentuate the merging of the outer and inner flows. The objective of the focused schlieren work was to characterize the mixing performance inside of the ejector. Using flow visualization allowed this to be accomplished in a non-intrusive manner.

Mitchell, L. Kerry↗

Workshop on evolution of igneous asteroids: Focus on Vesta and the HED meteorites

Recently, the geology of the surface of Vesta has been coming to light. In 1983 Gaffey first began showing maps of the surface geology of Vesta constructed from numerous spectra obtained at different times as the asteroid rotated. By noting the details of spectral variation with rotation, he was able to develop two possible gross-scale geologic maps of Vesta showing the distributions of mafic and ultramafic materials. These maps were published in 1997. Finally, the capabilities of the Hubble Space Telescope were brought to bear on Vesta and images with a resolution of about 50 km were obtained using four different filters by Binzel and co-workers. Maps produced by this team published in 1997 began to reveal the geology of Vesta in sufficient detail that crude interpretations of the geologic history of the asteroid could be attempted. Additionally, in 1993 Binzel and Xu published a study of small asteroids in the region near Vesta in orbital-element space. In this study, they showed that there are a number of asteroids a few kilometers in size with reflectance spectra like that of Vesta that form a trail in orbital-element space from near Vesta to near resonances that can more easily supply material to near-Earth space. Binzel and Xu thus concluded that these small asteroids were spells of Vesta ejected by impact and that some of their brethren had been perturbed to Earth-approaching orbits. They suggested that these latter were the immediate parents of HED meteorites. This seemed to remove a long-standing dynamical objection to Vesta as the HED parent body, as discussed by Wasson and Wetherill in 1979. Within the last few years, NASA has initiated the Discovery program of low-cost, rapid-timescale development, exploration missions. Vesta has been proposed as an object worthy of study by a Discovery mission, although a Vesta mission has not yet been selected. With all the recent activity aimed at studying Vesta and the HED meteorites, and the possibility of a space mission to Vesta, we felt that time was ripe to convene a workshop bringing together astronomers, meteoriticists, and planetary geologists to focus on what could be learned about the geologic evolution of Vesta through integrating astronomical and HED meteorite studies. This, of course, assumes that the HED meteorites are from Vesta, and this issue was specifically addressed (but not resolved) in the workshop. Indeed, it seems likely that this issue can only be resolved by returning samples from Vesta for detailed study on Earth. The workshop was held at the LPI on October 16-18,1996, and was attended by some 70 scientists. Sessions included a set of talks on Earth- and space-based astronomical observations of Vesta plus the evidence pro and con for Vesta being the HED parent body, talks on the petrology and geochemistry of HED meteorites, talks on the formation and dynamics of ejecta from Vesta, talks on the thermal history of asteroids and HED meteorites, volcanic processes and differentiation history, and a short session devoted to possible missions to Vestal By all accounts, the workshop was considered a great success, although this is the opinion of a biased set of observers.

Mittlefehldt, D. W.↗

Interference of Backscatter from Two Droplets in a Focused Continuous Wave CO2 Doppler Lidar Beam

Interference due to the superposition of backscatter, beta, from two micron-sized droplets using a NASA/MSFC cw (continuous wave) CO2 Doppler lidar at 9.1 micrometer wavelength was detected for the first time. The resultant single beta signal from both droplets contained an interference structure with a well-defined periodicity which was accurately measured and compared with cw lidar theory. The agreement between measurements and theory is excellent, indicating that the interference arises because the droplets are moving at different speeds and, therefore, the relative droplet separation is not constant. This gives the superimposed beta signal from both droplets in the lidar beam moving in and out of constructive and destructive interference with a well-defined periodic structure. A measurement of a time-resolved signal pulse with an oscilloscope of the combined from two approx. 14.12 micrometers in diameter silicone oil droplets responding to the Gaussian lidar beam intensity at the lidar beam focus is shown. Full details of this laboratory experimental setup, particle generation method, measurement technique, and the cw lidar can be found elsewhere. The stream of silicone oil droplets resided at a Doppler-shift center frequency of f (sub D) approx. (3.4 plus or minus 0.2) MHz, giving droplet speed v approx.(21.9 plus or minus 1.3) ms (exp. -1). Also shown on a separate channel is the corresponding signature using an amplitude demodulator circuit designed to detect the amplitude envelope of f(sub D) within the pulse profile. beta from simultaneous droplet events show a complete cyclic interference structure of maximum and minimum. The average period T of the complete cycle of interference is 13.02 plus or minus.39 microseconds. Toward the right edge of the profile, the interference disappears because one of the droplets is leaving the lidar beam while the other one remains in the beam, thus, giving beta for a single droplet.

Jarzembski, Maurice A.↗

Evaluation of the Hydrodynamic Focusing Bioreactor (HDFB) and the Centrifugal Absorption Cartridge System (CACS) Performance Under Micro G

The Hydrodynamic Focusing Bioreactor (HDFB) technology is designed to provide a flow field with nearly uniform shear force throughout the vessel, which can provide the desired low shear force spatial environment to suspend three-dimensional cell aggregates while providing optimum mass transfer. The reactor vessel consists of a dome-shaped cell culture vessel, a viscous spinner, an access port, and a rotating base. The domed vessel face has a radius of R(o). and rotates at 0mega(o) rpm, while the internal viscous spinner has a radius of R(i) and rotates at 0mega(i) rpm. The culture vessel is completely filled with cell culture medium into which three-dimensional cellular structures are introduced. The HDFB domed vessel and spinner were driven by two independent step motors,

Gonda, Steve↗

An Update on the Development of a Line-Focus Refractive Concentrator Array

Concentrator arrays offer a number of generic benefits for space (i.e. high array efficiency, protection from space radiation effects, minimized plasma interactions, etc.). The line-focus refractive concentrator concept, however, also offers two very important advantages: (1) relaxation of precise array tracking requirements to only a single axis and (2) low-cost mass production of the lens material. The linear refractive concentrator can be designed to provide an essentially flat response over a wide range of longitudinal errors for satellites having only single-axis tracking capability. New panel designs emphasize light weight, high stiffness, stowability and ease of manufacturing and assembly. This paper will address the current status of the concentrator program with special emphasis on the design implications, and flexibility, of using a linear refractive concentrator lens as well as detail the recent fabrication of prototype hardware.

Piszczor, Michael F.↗

Fracture Tests of Etched Components Using a Focused Ion Beam Machine

Many optical MEMS device designs involve large arrays of thin (0.5 to 1 micron components subjected to high stresses due to cyclic loading. These devices are fabricated from a variety of materials, and the properties strongly depend on size and processing. Our objective is to develop standard and convenient test methods that can be used to measure the properties of large numbers of witness samples, for every device we build. In this work we explore a variety of fracture test configurations for 0.5 micron thick silicon nitride membranes machined using the Reactive Ion Etching (RIE) process. Testing was completed using an FEI 620 dual focused ion beam milling machine. Static loads were applied using a probe. and dynamic loads were applied through a piezo-electric stack mounted at the base of the probe. Results from the tests are presented and compared, and application for predicting fracture probability of large arrays of devices are considered.

Kuhn, Jonathan, L.↗

Affordable Design: A Methodolgy to Implement Process-Based Manufacturing Cost into the Traditional Performance-Focused Multidisciplinary Design Optimization

The primary objective of this paper is to demonstrate the use of process-based manufacturing and assembly cost models in a traditional performance-focused multidisciplinary design and optimization process. The use of automated cost-performance analysis is an enabling technology that could bring realistic processbased manufacturing and assembly cost into multidisciplinary design and optimization. In this paper, we present a new methodology for incorporating process costing into a standard multidisciplinary design optimization process. Material, manufacturing processes, and assembly processes costs then could be used as the objective function for the optimization method. A case study involving forty-six different configurations of a simple wing is presented, indicating that a design based on performance criteria alone may not necessarily be the most affordable as far as manufacturing and assembly cost is concerned.

Bao, Han P.↗

Focus of NASA's Spaceliner 100 Investment Area

This presentation discuss the goals and objectives of the SL100 Technology Focus. Some of the Technology objectives were to: increase system performance margin; drive down operations costs; drive down manufacturing and production costs; and drive down development test and evaluation costs.

Hueter, Uwe↗

Adjustable Focus Optical Correction Lens (AFOCL)

This report describes a metrology plan that was developed for the characterization of PLZT-based devices, such as the Adjustable Focus Optical Correction Lens (AFOCL) in support of and as part of the deliverables for NASA contract NAS8-00118. The areas to be investigated include intensiometric effects (those that limit or alter the intensity of the light transmitted through the optic); interferometric effects (the phase change induced through the optic); and polarimetric effects (evaluating the differential lag between two polarization states propagating through the optic). These distinct phenomena are often coupled together in real applications consequently, there is a need to develop different standardized testing apparatus to: (1) isolate one effect from another; (2) gather information for understanding the physical effects; (3) anchor wavefront corrector modeling efforts; (4) develop the ability to decouple different effects; (5) demonstrate the suitability of PLZT technology to perform wavefront correction. The Center for Applied Optics (CAO) at the University of Alabama in Huntsville (UAH) is skilled in the characterization of transmission wavefront shaping devices using traditional interferometers available within the CAO Optical Metrology Laboratory and their Advanced Polarization Test Facility. Besides the imaging and interferometers available, the polarimetry facility has at its disposal, a Mueller Matrix Imaging Polarimeter (MMIP) which is well suited to the characterization of SLMs, polarizers, and thin film coatings within the visible and near-IR spectrums. In addition, the phase-shifting interferometry facilities at NASA-MSFC and the unique interferometers they processes are some of the most advanced available and may be of value especially for performing real-time optical performance evaluation of AFOCL test components.

Peters, Bruce R.↗

First Images from HERO: A Hard-X-Ray Focusing Telescope

We are developing a balloon-borne hard-x-ray telescope that utilizes grazing incidence optics. Termed HERO, for High-Energy Replicated Optics, the instrument will provide unprecented sensitivity in the hard-x-ray region and will achieve milliCrab-level sensitivity in a typical 3-hour balloon-flight observation and 50 microCrab sensitivity on ultra-long-duration flights. A recent proof-of-concept flight, featuring a small number of mirror shells captured the first focused hard-x-ray images of galactic x-ray sources. Full details of the payload, its expected future performance and its recent measurements are provided.

Ramsey, Brian D.↗

HERO: Program Status and Fist Images from a Balloon-Borne Focusing Hard-X-ray Telescope

HERO is a balloon payload featuring shallow-graze angle replicated optics for hard-x-ray imaging. When completed, the instrument will offer unprecedented sensitivity in the hard-x-ray region, giving thousands of sources to choose from for detailed study on long flights. A recent proof-of-concept flight captured the first hard-x-ray focused images of the Crab Nebula, Cygnus X-1 and GRS 1915+105. Full details of the HERO program are presented, including the design and performance of the optics, the detectors and the gondola. Results from the recent proving flight are discussed together with expected future performance when the full science payload is completed.

Ramsey, B. D.↗

Global Plasmaspheric Imaging: A New "Light" Focusing on Familiar Questions

Until recently plasmaspheric physics, for that matter, magnetospheric physics as a whole, has relied primarily on single point in-situ measurement, theory, modeling, and a considerable amount of extrapolation in order to envision the global structure of the plasmasphere. This condition changed with the launch of the IMAGE satellite in March 2000. Using the Extreme Ultraviolet (EUV) imager on WAGE, we can now view the global structure of the plasmasphere bathed in the glow of resonantly scattered 30.4 nm radiation allowing the space physics community to view the dynamics of this global structure as never before. This talk will: (1) define the plasmasphere from the perspective of plasmaspheric physics prior to March 2000; (2) present a review of EUV imaging optics and the IMAGE mission; and focus on efforts to understand an old and familiar feature of plasmaspheric physics, embedded plasmaspheric density troughs, in this new global light with the assistance of forward modeling.

Adrian, M. L.↗

CRYSTAL-FACE: A Field Experiment and Modeling Program Focused on Tropical Anvils and Cirrus Layers

The Cirrus Regional Study of Tropical Anvils and Cirrus Layers - Florida Area Cirrus Experiment (CRYSTAL-FACE) is a measurement campaign designed to investigate tropical Cirrus cloud physical properties and formation processes. Understanding the production of upper tropospheric cirrus clouds is essential for the successful modeling of 'he Earth's climate. The deployment phase will occur in July, 2002 in southern Florida, USA. Several aircraft will be used, including the ER-2 and Proteus for cloud remote sensing, the WB-57 and Citation for in situ cloud measurements, the P-3 with a Doppler radar for characterization of convective systems, and the Twin otter for sampling of inflow airmasses. In addition, numerous ground-based and satellite remote sensing measurements will be contributing. A central focus of the mission is improvement of our ability to model cirrus clouds with numerical models. Several research groups with a variety of model types (cloud-resolving models, mesoscale models, weather-prediction models, and general circulation models) will be participating. Our hope is to fully characterize several mulonimbus/cirrus anvil systems that can be used as case studies for testing and improvement of the models. The models will be used for investigating cirrus generation and dissipation processes and the sensitivity of tropical cirrus to convective intensity and aerosol properties. Ultimately, we expect this effort to improve our ability to represent tropical cirrus in GCMs. A general description of the CRYSTAL-FACE program will be presented, with an emphasis on the cloud modeling approach.

Jenson, Eric↗

A Low Cost Electrostatically Focused TWT

Ring-loop circuits are well known for their simplicity, low cost, compactness, low mass, high gain and efficiency and absence of backward wave oscillations. Peak powers over 20 kw have been achieved. They also have low harmonic output and excellent phase performance. We have developed a double ring-loop circuit that permits electrostatic focusing of an electron beam to at least 0.4 micro pervs. This eliminates the magnet stack and further lowers cost and weight. It permits glass rod fastening of circuit elements as well as gun and collector assemblies, as is done in cathode ray tubes. Using CRT construction techniques, the TWT can be built on automated equipment.

Vancil, Bernard K.↗

Bubble Experiments on the Hydrodynamic Focusing Bioreactor-Space (HFB-S)

The Hydrodynamic Focusing Bioreactor-Space (HFB-S) is being developed as a drop-in replacement for the Rotating Wall Perfused Vessel (RWPV) bioreactor currently planned for use on the International Space Station (ISS). Only the vessel itself is proposed for change, the supporting hardware will remain the same. These bioreactors are used for the growth of three-dimensional tissue culture that cannot be done in normal gravity labs. The bioreactors provide a continual supply of oxygen for cell growth, as well as periodic replacement of cell culture media with nutrients. The RWPV has had many successful flights on the space shuttle, but longer duration missions onboard the Mir Space Station resulted in bubbles inside the vessel that were detrimental to the science. It is believed that procedural changes can prevent bubble formation, but the HFB-S must not only provide a mechanism of bubble removal, but must also meet strict requirements for a low-shear environment and uniform oxygen concentration distribution for optimum cell tissue growth. A detailed technical objective (DTO) flight on the space shuttle to fully evaluate the HFB-S is currently in the planning stages. Ground-based activities are also underway to quanitify the characteristics of the HFB-S. Computational studies are being used to predict the internal fluid flow and cell trajectories. These computations will be compared to ground-based flow visualization experiments. Comparative studies of ground-based cell growth between the RWPV and the HFB-S are also in progress. These studies have shown that the HFB-S functions well as a bioreactor in normal gravity. Bubble motion and bubble removal are being studied using computational predictions as well as experimental validation.

Charles Niederhaus↗

Focused Ion Beam Recovery and Analysis of Interplanetary Dust Particles (IDPs) and Stardust Analogues

Meteoritics research is a major beneficiary of recent developments in analytical instrumentation [1,2]. Integrated studies in which multiple analytical techniques are applied to the same specimen are providing new insight about the nature of IDPs [1]. Such studies are dependent on the ability to prepare specimens that can be analyzed in multiple instruments. Focused ion beam (FIB) microscopy has revolutionized specimen preparation in materials science [3]. Although FIB has successfully been used for a few IDP and meteorite studies [1,4-6], it has yet to be widely utilized in meteoritics. We are using FIB for integrated TEM/NanoSIMS/synchrotron infrared (IR) studies [1].

Graham, G. A.↗

Focused Assessment with Sonography for Trauma in weightlessness: a feasibility study

BACKGROUND: The Focused Assessment with Sonography for Trauma (FAST) examines for fluid in gravitationally dependent regions. There is no prior experience with this technique in weightlessness, such as on the International Space Station, where sonography is currently the only diagnostic imaging tool. STUDY DESIGN: A ground-based (1 g) porcine model for sonography was developed. We examined both the feasibility and the comparative performance of the FAST examination in parabolic flight. Sonographic detection and fluid behavior were evaluated in four animals during alternating weightlessness (0 g) and hypergravity (1.8 g) periods. During flight, boluses of fluid were incrementally introduced into the peritoneal cavity. Standardized sonographic windows were recorded. Postflight, the video recordings were divided into 169 20-second segments for subsequent interpretation by 12 blinded ultrasonography experts. Reviewers first decided whether a video segment was of sufficient diagnostic quality to analyze (determinate). Determinate segments were then analyzed as containing or not containing fluid. A probit regression model compared the probability of a positive fluid diagnosis to actual fluid levels (0 to 500 mL) under both 0-g and 1.8-g conditions. RESULTS: The in-flight sonographers found real-time scanning and interpretation technically similar to that of terrestrial conditions, as long as restraint was maintained. On blinded review, 80% of the recorded ultrasound segments were considered determinate. The best sensitivity for diagnosis in 0 g was found to be from the subhepatic space, with probability of a positive fluid diagnosis ranging from 9% (no fluid) to 51% (500 mL fluid). CONCLUSIONS: The FAST examination is technically feasible in weightlessness, and merits operational consideration for clinical contingencies in space.

NASA Discipline Life Sciences Technologies↗