At least 721 records · Page 40

Uranium Oxide Synthetic Pathway Discernment through Unsupervised Morphological Analysis

We present a novel unsupervised machine learning method for quantitative representation of scanning electron micrographs and its applications and performance for nuclear forensic analysis of uranium ore concentrates. The method uses a vector quantizing variational autoencoder followed by a histogram operation to encode a micrograph into a single dimensional representation, called the latent vector. The method requires no extant labeling of the data and can be applied over large datasets of micrographs with minimal human interaction. The representations generated are broadly descriptive of each micrograph and the microstructure of the material imaged. In the case of uranium ore concentrate analysis, the representations were amenable to processing reagent and ore concentrate species classification with accuracy of 81:8%, which is competitive with state-of-the-art supervised networks. The representations were also used to classify previously unseen processing routes, were able to classify imaging parameters such as magnification (to 76:0% accuracy), were able to classify fine grained process parameters such as calcining temperature (to 74:4% accuracy), and their informatic properties indicate that they are generally descriptive of the image represented. This method can be applied across microstructure analysis fields to perform quantitative analysis without the need for labor intensive and possibly biased human analysis.

Scanning Electron Microscopy, Vector Quantizing Va↗

Identification of uranium oxidation states using oxygen K-edge scanning transmission X-ray microscopy

The field of nuclear forensics is growing in importance, and the increasing capabilities at synchrotron radiation light sources enable non-destructive characterization of oxide particles with better spatial, compositional, and oxidation state speciation resolution than ever before. Here, uranium oxide particles derived from multiple wet chemical processing methods were examined using a scanning transmission X-ray microscope (STXM), and a weakly-supervised method was developed to automatically analyze the collected data. Multiple uranium oxidation states were observed and quantified within and between samples, yielding information about differences between particles produced via the various processing routes.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Production of anhydrous ƒ-element fluorides through the ionothermal treatment of ƒ-element oxalates

The pivotal role of uranium and plutonium fluorides in the nuclear fuel cycle, particularly in the pyrochemical reduction process, is well recognized. Traditionally, the fluorination of uranium and plutonium materials relies on the use of highly toxic and corrosive gases (e.g., HF (g) , F 2(g) ). Herein, we present an alternative approach using the ionic liquid 1‑butyl‑3-methylimidazolium hexafluorophosphate ([Bmim][PF 6 ] (l) ) and/or hexafluorophosphoric acid (HPF 6(aq) ) as fluorinating agents for the ƒ-element oxalates M$^{III}_{2}$(C 2 O 4 ) 3 ∙ 9H 2 O (s) M$^{III}_{2}$(C 2 O 4 ) 3 ∙ 9H 2 O (s) (M III = Ce, Pu) and M IV (C 2 O 4 ) 2 ∙ 6H 2 O (s) (M IV = Th, U). Our findings demonstrate that [Bmim][PF 6 ] (l) and HPF 6(aq) enable the ionothermal fluorination of ƒ-element oxalates, resulting in the formation of anhydrous CeF 3(s) , ThF 4(s) , and UF 4(s) within 2 hours at 200 °C. This method also facilitates the partial fluorination of plutonium(III) oxalate, yielding a mixture of anhydrous PuF 3(s) and an unidentified phase. Overall, the ionothermal treatment approach offers a safer and more efficient means of producing anhydrous ƒ-element fluorides than conventional methods involving hazardous gases. In addition, we describe the morphology of UF 4(s) materials as a function of production route and demonstrate the presence of morphological signatures that could be used during a nuclear forensic investigation.

Cerium↗

Investigating rapid alpha-decay induced aging of 238 PuO 2 by Raman Spectroscopy

Investigating alpha-decay induced aging in PuO 2 is useful in nuclear forensics; helping to determine the time since last calcination. This was previously investigate by monitoring the damage to 240 PuO 2 over the course of a few years. The rate of alpha-decay induced aging has long been assumed to scale only with the decay rate of other isotopes without direct verification. This article reports the first alpha-decay aging study of 238 PuO 2 by Raman spectroscopy. Contrary to the expected 10 days for 238 PuO 2 to reach steady state based on 240 PuO 2 studies, the alpha aging curve reached an approximate steady state ∼24–30 h after laser annealing. While the cause of the order of magnitude decrease is unknown, it is speculated that dynamic annealing could contribute to the differences in rate of induced aging. The Raman spectra of annealed and aged 238 PuO 2 matched the expected features in 239 PuO 2 and 240 PuO 2 spectra; showing no formation of new stable chemical species in the material such as secondary Pu oxide phases (e.g., Pu 4 O 9 ). In conclusion, results indicate that 238 Pu could be leveraged for rapid alpha-decay aging studies to characterize alpha-decay induced features and better understand matrix temperatures and the annealing of Frankel pair defects.

Actinide↗

Microstructural characterization of plutonium oxalate and oxide particles by three-dimensional focused ion beam tomography

Focused ion beam (FIB) tomography was used to characterize three-dimensional (3D) internal microstructures of plutonium oxalate and oxide particles. Sequential two-dimensional (2D) sectioning and imaging using FIB and 3D image reconstruction were used to elucidate and distinguish internal pore microstructure and distribution in plutonium oxide particles calcined from plutonium oxalate precipitates. The results show that the plutonium oxide particles have a significant increase in pore volume fraction while retaining the exterior morphological shape of the corresponding oxalate precipitates. This technique enables the examination of the internal structure of radioactive microparticles for nuclear forensics that is not available with conventional microscopy.

36 MATERIALS SCIENCE↗

Dense autoencoders, clustering techniques, and semi-supervised learning for HPGe $γ$-spectra

Classifying high-resolution gamma spectra by their isotopic content is an essential task in nuclear forensics and other applications. Traditional analysis methods are often time-intensive, but machine learning (ML) may help analysts quickly process many spectra. Such methods tend to rely on abundant, well-labeled data for training. Historical gamma data exists in various fields but is not uniformly useful for supervised ML due to inconsistent labeling. Here, to address some of these challenges, we present a method to classify and organize unlabeled data from high-purity germanium detectors using an autoencoding neural network (autoencoder). We trained dense autoencoders to compress gamma data into latent representations that enable efficient data characterization. By clustering the encoded spectra or lower-dimensional mappings of them, we identified and removed portions of over-abundant data categories, resulting in a more balanced dataset and improved autoencoder performance. This encoding and clustering pipeline also enabled the organization of spectra into self-consistent categories. Finally, we found that encoded representations showed potential as inputs for semi-supervised learning of nuclide identification (NID) labels, achieving an average F1 score of 0.85 ± 0.03 when mapping encodings to a set of 65 isotope labels.

Autoencoders↗

Elemental source attribution signatures for calcium ammonium nitrate (CAN) fertilizers used in homemade explosives

Calcium ammonium nitrate (CAN) is a widely available fertilizer composed of ammonium nitrate mixed with some form of calcium carbonate such as limestone or dolomite. CAN is also frequently used to make homemade explosives. The potential of using elemental profiling and chemometrics to match both pristine and reprocessed CAN fertilizers to their factories for use in future forensic investigations was examined. Inductively coupled plasma-mass spectrometry (ICP-MS) analysis was performed on 64 elements in 125 samples from 11 CAN stocks from 6 different CAN factories. Fisher ratio, degree-of-class-separation, and partial least squares discriminant analysis (PLSDA) were used to develop a model using the concentrations of Na, V, Mn, Cu, Ga, Sr, Ba and U to classify a validation set of CAN samples into 5 factory groups; one group was two factories from the same fertilizer company. In terms of the pristine CAN samples, i.e., unadulterated prills, 64% of the test samples were matched to their correct factory group with zero false positives. The same PLSDA model was used to correctly match 100% of the CAN samples that were reprocessed by crushing and mixing the CAN with powdered sugar. In the case of crushed CAN samples mixed with aluminum powder, correct matches were made for zero to 100% of the samples depending on the factory the CAN originated. Remarkably, for one factory, 100% of the ammonium nitrate samples that were extracted from CAN using tap or bottled water were matched to the correct CAN factory group. Lastly, the water-insoluble (calcium carbonate) portions of CAN provided a greater degree of discrimination between factories than the water-soluble portions of CAN. In summary, this work illustrates that sourcing unadulterated CAN fertilizer can potentially be done with high frequency and high confidence using elemental profiling and chemometrics while the sourcing of reprocessed CAN is dependent on how much an adulterant alters the recovered elemental profile of CAN.

chemical forensics↗

Part 1: Tracing Russian VX to its synthetic routes by multivariate statistics of chemical attribution signatures

Chemical attribution signatures (CAS) associated with different synthetic routes used for the production of Russian VX (VR) were identified here. The goal of the study was to retrospectively determine the production method employed for an unknown VR sample. Six different production methods were evaluated, carefully chosen to include established synthetic routes used in the past for large scale production of the agent, routes involving general phosphorus-sulfur chemistry pathways leading to the agent, and routes whose main characteristic is their innate simplicity in execution. Two laboratories worked in parallel and synthesized a total of 37 batches of VR via the six synthetic routes following predefined synthesis protocols. The chemical composition of impurities and byproducts in each route was analyzed by GC/MS-EI and 49 potential CAS were recognized as important markers in distinguishing these routes using Principal Component Analysis (PCA). The 49 potential CAS included expected species based on knowledge of reaction conditions and pathways but also several novel compounds that were fully identified and characterized by a combined analysis that included MS-CI, MS-EI and HR-MS. The CAS profiles of the calibration set were then analyzed using partial least squares discriminant analysis (PLS-DA) and a cross validated model was constructed. The model allowed the correct classification of an external test set without any misclassifications, demonstrating the utility of this methodology for attributing VR samples to a particular production method. This work is part one of a three-part series in this Forensic VSI issue of a Sweden-United States collaborative effort towards the understanding of the CAS of VR in diverse batches and matrices. This part focuses on the CAS in synthesized batches of crude VR and in the following two parts of the series the influence of food matrices on the CAS profiles are investigated.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Chemical separation and measurement of platinum activation products

Here, a method has been developed to purify and measure platinum radioisotopes in the presence of fission products and environmental constituents. The method uses a combination of cation exchange and anion exchange chromatography and selective precipitation steps to remove other radioisotopes from the sample. The addition of stable platinum carrier allows for a gravimetric determination of the chemical yield of the procedure. Overall, the method is fast, simple, and potentially applicable for rapid turnaround of unknown samples. Using this method, multiple platinum radioisotopes were measured in two different irradiation experiments. The measured ratios of the platinum radioisotopes clearly reflect the neutron spectrum of the irradiation, suggesting that platinum radioisotopes could be valuable signatures in nuclear forensic analyses.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Chemometrics and visible diffuse reflectance spectroscopy to classify plutonium dioxide

Diffuse reflectance (DR) spectra in the Vis-NIR (∼380–1050 nm) region were acquired for a series of PuO 2 samples with a spot size of about 10 × 10 μm. Two batches of six PuO 2 samples, synthesized approximately 7.5 months apart, were prepared using both Pu(III) and Pu(IV) oxalate precursors at three distinct calcination temperatures (450, 650, and 950 °C). This yielded a total of 12 PuO 2 samples and 433 DR spectra. The DR spectrum of PuO 2 contained numerous peaks in the visible region, and characteristic features were identified with respect to calcination temperature and chemistry. A distinct peak multiplet near 615 nm was observed for samples prepared at low calcination temperatures, and a peak near 660 nm was observed for higher calcination temperatures. A multivariate classification strategy based on principal component analysis (PCA) was developed to distinguish PuO 2 calcination temperatures of 450, 650, and 950 °C with 100 % accuracy. Classification results also indicate the potential to distinguish chemical processing history (i.e., Pu(III) or Pu(IV)) based on the spectra with 72 % accuracy based on k-nearest neighbors applied to the PCA scores. Partial least squares discriminant analysis was used to identify variation among batches with 88 % accuracy and found that peaks near 669, 681, 811, and 970 nm were the most useful for predicting the batch identity. Here, this work demonstrates how micro-diffuse reflectance spectroscopy and chemometrics can be used to classify PuO 2 processing history based on Vis-NIR spectral features. Combining the chemometric approach with mapping sequences could provide a rapid, nondestructive approach to classify Pu oxide materials for environmental, forensics, and nonproliferation applications.

Actinide↗

147 Nd Quantification Using HSCCC-Purified Samples

Quantifying the fission product 147 Nd in nuclear debris samples is an important component of post-detonation nuclear forensics. The most accurate quantifications are obtained when Nd is purified from all other fission products, actinides, activation products, and environmental matrix contained within the debris. In this study, a recently developed method for Nd purification was tested, purifying 147 Nd from solutions of mixed fission products using high-speed counter-current chromatography (HSCCC). Importantly, the new method allowed for faster elution of Nd from the column as compared with established high performance liquid chromatography (HPLC) methods, and resulted in accurate/precise 147 Nd quantification by gamma-ray spectrometry. While the up-front equipment costs associated with HSCCC may be higher, its operational costs are on par with those of HPLC (solvents, extractants, power). Gas-flow proportional beta decay counting revealed contamination from the nearest neighbor lanthanide 143 Pr (a gamma-silent radioisotope) in the HSCCC-purified samples, but the activity contribution from 147 Nd could still be quantified. Remarkably consistent elution profiles were observed for the HSCCC method, spanning rare earth element (REE) loadings of more than 10 orders of magnitude (tracer to mmol quantities). In conclusion, the reliability and speed of the new method suggest utility for the rapid separation and quantification of 147 Nd in unknown samples.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Characterization of Residual Medium Peptides from Yersinia pestis Cultures

Using a range of common microbial medium formulations (TSB, BHI, LB, and G-media), two attenuated strains of Y. pestis (KIM D27 (pgm-) and KIMD1 lcr-) were cultivated in triplicate. These cellular suspensions were used to develop a method of extracting residual medium peptides from the final microbial preparation to assess their relative abundance and identity. Across the conditions examined, which included additional cellular washing and different forms of microbial inactivation, residual medium peptides were detected. Despite the range of growth medium sources used and the associated manufacturing processes used in their production, a high degree of peptide similarity was observed for a given medium recipe. These results demonstrate that residual medium peptides are retained using traditional microbial cultivation techniques and may be used to inform forensic investigations with respect to production deduction.

Microbial Forensics, Proteomics, Peptidomic, Mass ↗

Tracking Radionuclide Fractionation in the First Atomic Explosion Using Stable Elements

Compositional analysis of postdetonation fallout is a tool for forensic identification of nuclear devices. However, the relationship between device composition and fallout composition is difficult to interpret because of the complex combination of physical mixing, nuclear reactions, and chemical fractionations that occur in the chaotic nuclear fireball. By using a combination of in situ microanalytical techniques (electron microprobe analysis and secondary ion mass spectrometry), we show that some heavy stable elements (Rb, Sr, Zr, Ba, Cs, Ba, La, Ce, Nd, Sm, Dy, Lu, U, Th) in glassy fallout from the first nuclear test, Trinity, are reliable chemical proxies for radionuclides generated during the explosion. Stable-element proxies show that radionuclides from the Trinity device were chemically, but not isotopically, fractionated by condensation. Moreover, stable-element proxies delineate chemical fractionation trends that can be used to connect present-day fallout composition to past fireball composition. Stable-element proxies therefore offer a novel approach for elucidating the phenomenology of the nuclear fireball as it relates to the formation of debris and the fixation of device materials within debris.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Quantitative Encapsulation and Homogeneity Assessment of Sol–Gel Based Nuclear Explosive Debris Simulants

Nuclear explosive debris simulants are an important material in training and validating aspects of post-detonation nuclear forensic processes. Realistic simulants should replicate several aspects of nuclear explosive debris such as the size, shape, color, density, and chemical and radiological properties. Silica particles produced via sol-gel synthesis have recently been found to successfully reproduce many of these parameters including the controllable incorporation of radionuclide content. However, to be useful as a benchmarking material for validation and verification of laboratory methodologies, radionuclide content from batch-to-batch must be reproducible. Here, in this work, we explore the variance in radionuclide distribution incorporated into sol-gel benchmarking materials with respect to sample subdivision. Results will help inform the sample sizes required to minimize variance between samples.

36 - MATERIALS SCIENCE↗

Machine Learning–Augmented Laser-Induced Breakdown Spectroscopy for Spectral Discrimination of Iron Oxalates

Enhanced characterization and phase identification of post-PUREX Pu Oxalates (PuOXA) are pivotal for nonproliferation and pre-detonation nuclear forensics. Despite significant advances in the characterization of PuO 2 samples, little is known about the impact of both the chemical structure and oxidation states of PuOXA (i.e., Pu(III) and Pu(IV)) have on optical emission signatures. Here, we demonstrate the analytical capabilities of laser-induced breakdown spectroscopy (LIBS) applied to Fe(II) and Fe(III) oxalate samples as surrogates for PuOXA, highlighting the discriminating features in the LIBS emission spectra arising from differences in the oxidation states within mixed FeOXA samples. We report the enhancement of spectral feature selection using Principal Component Analysis (PCA), which enables the analytical superiority of machine learning algorithms such as Linear Discriminant Analysis (LDA), Quadratic Discriminant Analysis (QDA), Partial Least Squares Regression (PLSR), Support Vector Regression (SVR), and Random Forest Regression (RFR) over conventional univariate techniques for phase discrimination and chemometric analysis. Cluster analysis revealed how both matrix effects and laser ablation influence cluster separability by introducing spectral artifacts that misdirect the maximization of variance. PCA-selected emission lines were used in the regression models, demonstrating that both univariate and multivariate linear regression models (i.e., PLSR and SVR) can achieve acceptable performance, with machine learning models outperforming conventional calibration regressions. Furthermore, the application of non-linearly activated PCA-selected emission lines illustrates how simplifying the data while retaining captured variance enables the use of less complex and more computationally efficient models. Furthermore, this is particularly evident in the underperformance of RFR, which suffers from increased computational costs and overfitting owing to its high complexity.

Oxalates↗

Elephant range and population, strontium isotopes, and genetics combine to give local-scale specificity to ivory hotspot tracking

We use Sr isotopes to increase the precision of DNA-based origin estimates of wildlife products. Population information is used to develop Sr isotope Elephant Polygons that are overlaid onto the region of origin identified by DNA assignment to determine the sources of seized ivory samples. Our approach is cognizant of isotope mixing due to isotope turnover within animals and also of the large home range of elephants or other mobile species. Genetic information from 3 different law enforcement ivory seizures suggests a region of origin confined to Kenya and Tanzania in eastern Africa. We determine characteristic 87 Sr/ 86 Sr ratios for each of 25 different Elephant Polygons within this region using analyses of more the 600 known-origin reference samples. Using both the 87 Sr/ 86 Sr ratios of the seized ivory samples and elephant population estimates from individual Elephant Polygons we find that at least 75 % of the samples likely came from a single Elephant Polygon which includes the Tsavo National Parks in Kenya and the Mkomazi National Park in Tanzania. A few samples may have come from other regions, most likely from Tanzania. This study illustrates the value of combining genetics, isotope geochemistry, and population surveys in wildlife forensics studies.

Africa↗

Rapid Characterization and Statistical Analysis of High-Volume Field-Harvested Photovoltaic Connectors

Photovoltaic (PV) installations heavily depend on connectors for efficient module and string interconnections without requiring skilled labor. Yet this seemingly innocuous component of PV systems is a leading cause of module failures, multiple high-profile fires, and lawsuits in the PV industry. This work aims to answer critical questions regarding why connectors fail and the contributing factors to their failure. The study involves collecting and analyzing more than 17,000 field-harvested connectors from various solar installations across the United States. The vast dataset, which includes connector metadata, visual inspections, and resistance measurements, provides unprecedented insight into the state of health of PV connectors across the US, including the geographic locations, connector types, and installation practices most prone to failures. The work presented here describes a novel rapid characterization method for processing large numbers of connectors and is supported by parallel forensic analysis to discern the root causes of failures as well as a levelized cost of lifetime model to determine the economic ramifications of connector failure. Ultimately, the findings may inform PV developers about the best practices to extend connector longevity and lead to more resilient and reliable PV systems.

connectors↗

Objective analysis of impressed chisel toolmarks

Historical and recent challenges to the practice of comparative forensic examination have created a driving force for the formation of objective methods for toolmark identification. In this study, fifty sequentially manufactured chisels were used to create impression toolmarks in lead (500 toolmarks total). An algorithm previously used to statistically separate known matching and nonmatching striated screwdriver marks and quasi-striated plier marks was used to evaluate the chisel marks. Impression toolmarks, a more complex form of toolmark, pose a more difficult test for the algorithm that was originally designed for striated toolmarks. Lastly, results show in this instance that the algorithm can separate matching and nonmatching impression marks, providing further validation of the assumption that toolmarks are identifiably unique.

47 OTHER INSTRUMENTATION↗