Clinical Results of Image-Guided Deep Inspiration Breath Hold Breast Irradiation

Purpose: To evaluate the feasibility, cardiac dose reduction, and the influence of the setup error on the delivered dose for fluoroscopy-guided deep inspiration breath hold (DIBH) irradiation using a cone-beam CT for irradiation of left-sided breast cancer patients. Methods and Materials: Nineteen patients treated according to the DIBH protocol were evaluated regarding dose to the ipsilateral breast (or thoracic wall), heart, (left ventricle [LV]and left anterior descending artery [LAD]), and lung. The DIBH treatment plan was compared to the free-breathing (FB) treatment planning and to the dose data in which setup error was taken into account (i.e., actual delivered dose). Results: The largest setup variability was observed in the direction perpendicular to the RT field ({mu} = -0.8 mm, {Sigma} = 2.9 mm, {sigma} = 2.0 mm). The mean (D{sub mean}) and maximum (D{sub max}) doses of the DIBH treatment plan was significantly lower compared with the FB treatment plan for the heart (34% and 25%, p < 0.001), LV (71% and 28%, p < 0.001), and LAD (52% and 39.8%, p < 0.001). For some patients, large differences were observed between the heart D{sub max} according to the DIBH treatment plan and the actual delivered dose (up to 71%), although D{sub max} was always smaller than the planned FB dose (mean group reduction = 29%, p < 0.001). Conclusion: The image-guided DIBH treatment protocol is a feasible irradiation method with small setup variability that significantly reduces the dose to the heart, LV, and LAD.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Potentials and Limitations of Guiding Liver Stereotactic Body Radiation Therapy Set-Up on Liver-Implanted Fiducial Markers

Purpose: We investigated the potentials and limitations of guiding liver stereotactic body radiation therapy (SBRT) set-up on liver-implanted fiducial markers. Methods and Materials: Twelve patients undergoing compression-supported SBRT in a stereotactic body frame received fluoroscopy at treatment preparation and before each treatment fraction. In fluoroscopic videos we localized the markers and diaphragm tip at expiration and the spine (measurements on free-breathing and abdominal compression). Day-to-day displacements, rotations (markers only), and deformations were determined. Marker guidance was compared to conventional set-up strategies in treatment set-up simulations. Results: For compression, day-to-day motion of markers with respect to their centers of mass (COM) was {sigma} = 0.9 mm (random error SD), {Sigma} = 0.4 mm (systematic error SD), and <2.1 mm (maximum). Consequently, assuming that markers were closely surrounding spherical tumors, marker COM-guided set-up would have required safety margins of {approx}2 mm. Using marker COM as the gold standard, other set-up methods (using no correction, spine registration, and diaphragm tip craniocaudal registration) resulted in set-up errors of 1.4 mm < {sigma} < 2.8 mm, 2.6 mm < {Sigma} < 5.1 mm, and 6.3 mm < max < 12.4 mm. Day-to-day intermarker motion of <16.7%, 2.2% median, and rotations between 3.5{sup o} and 7.2{sup o} were observed. For markers not surrounding the tumor, e.g., 5 cm between respective COMs, these changes could effect residual tumor set-up errors up to 8.4 mm, 1.1 mm median (deformations), and 3.1 mm to 6.3 mm (rotations). Compression did not systematically contribute to deformations and rotations, since similar results were observed for free-breathing. Conclusions: If markers can be implanted near and around the tumor, residual set-up errors by marker guidance are small compared to those of conventional set-up methods, allowing high-precision tumor radiation set-up. However, substantial errors may result if markers are not implanted precisely, requiring further research to obtain adequate safety margins.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Dose-Volume Histogram Parameters and Late Side Effects in Magnetic Resonance Image-Guided Adaptive Cervical Cancer Brachytherapy

Purpose: To evaluate the predictive value of dose-volume histogram (DVH) parameters for late side effects of the rectum, sigmoid colon, and bladder in image-guided brachytherapy for cervix cancer patients. Methods and Materials: A total of 141 patients received external-beam radiotherapy and image-guided brachytherapy with or without chemotherapy. The DVH parameters for the most exposed 2, 1, and 0.1 cm{sup 3} (D{sub 2cc}, D{sub 1cc}, and D{sub 0.1cc}) of the rectum, sigmoid, and bladder, as well as International Commission on Radiation Units and Measurements point doses (D{sub ICRU}) were computed. Total doses were converted to equivalent doses in 2 Gy by applying the linear-quadratic model ({alpha}/{beta} = 3 Gy). Late side effects were prospectively assessed using the Late Effects in Normal Tissues-Subjective, Objective, Management and Analytic score. The following patient groups were defined: Group 1: no side effects (Grade 0); Group 2: side effects (Grade 1-4); Group 3: minor side effects (Grade 0-1); and Group 4: major side effects (Grade 2-4). Results: The median follow-up was 51 months. The overall 5-year actuarial side effect rates were 12% for rectum, 3% for sigmoid, and 23% for bladder. The mean total D{sub 2cc} were 65 {+-} 12 Gy for rectum, 62 {+-} 12 Gy for sigmoid, and 95 {+-} 22 Gy for bladder. For rectum, statistically significant differences were observed between Groups 1 and 2 in all DVH parameters and D{sub ICRU}. Between Groups 3 and 4, no difference was observed for D{sub 0.1cc.} For sigmoid, significant differences were observed for D{sub 2cc} and D{sub 1cc}, but not for D{sub 0.1cc} in all groups. For bladder, significant differences were observed for all DVH parameters only comparing Groups 3 and 4. No differences were observed for D{sub ICRU}. Conclusions: The parameters D{sub 2cc} and D{sub 1cc} have a good predictive value for rectal toxicity. For sigmoid, no prediction could be postulated because of limited data. In bladder, DVH parameters were predictive only for major toxicity.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

High Dose-Per-Fraction Irradiation of Limited Lung Volumes Using an Image-Guided, Highly Focused Irradiator: Simulating Stereotactic Body Radiotherapy Regimens in a Small-Animal Model

Purpose: To investigate the underlying biology associated with stereotactic body radiotherapy (SBRT), both in vivo models and image-guided, highly focal irradiation systems are necessary. Here, we describe such an irradiation system and use it to examine normal tissue toxicity in a small-animal model at lung volumes similar to those associated with human therapy. Methods and Materials: High-dose radiation was delivered to a small volume of the left lung of C3H/HeJCr mice using a small-animal stereotactic irradiator. The irradiator has a collimation mechanism to produce focal radiation beams, an imaging subsystem consisting of a fluorescent screen coupled to a charge-coupled device camera, and a manual positioning stage. Histopathologic examination and micro-CT were used to evaluate the radiation response. Results: Focal obliteration of the alveoli by fibrous connective tissue, hyperplasia of the bronchiolar epithelium, and presence of a small number of inflammatory cells are the main reactions to low-volume/high-dose irradiation of the mouse lung. The tissue response suggested a radiation dose threshold for early phase fibrosis lying between 40 and 100 Gy. The irradiation system satisfied our requirements of high-dose-rate, small beam diameter, and precise localization and verification. Conclusions: We have established an experimental model and image-guided animal irradiation system for the study of high dose per fraction irradiations such as those used with SBRT at volumes analogous to those used in human beings. It will also allow the targeting of specific anatomical structures of the thorax or ultimately, orthotopic tumors of the lung.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Electromagnetic-Guided Dynamic Multileaf Collimator Tracking Enables Motion Management for Intensity-Modulated Arc Therapy

Purpose: Intensity-modulated arc therapy (IMAT) is attractive because of high-dose conformality and efficient delivery. However, managing intrafraction motion is challenging for IMAT. The purpose of this research was to develop and investigate electromagnetically guided dynamic multileaf collimator (DMLC) tracking as an enabling technology to treat moving targets during IMAT. Methods and Materials: A real-time three-dimensional DMLC-based target tracking system was developed and integrated with a linear accelerator. The DMLC tracking software inputs a real-time electromagnetically measured target position and the IMAT plan, and dynamically creates new leaf positions directed at the moving target. Low- and high-modulation IMAT plans were created for lung and prostate cancer cases. The IMAT plans were delivered to a three-axis motion platform programmed with measured patient motion. Dosimetric measurements were acquired by placing an ion chamber array on the moving platform. Measurements were acquired with tracking, without tracking (current clinical practice), and with the phantom in a static position (reference). Analysis of dose distribution differences from the static reference used a {gamma}-test. Results: On average, 1.6% of dose points for the lung plans and 1.2% of points for the prostate plans failed the 3-mm/3% {gamma}-test with tracking; without tracking, 34% and 14% (respectively) of points failed the {gamma}-test. The delivery time was the same with and without tracking. Conclusions: Electromagnetic-guided DMLC target tracking with IMAT has been investigated for the first time. Dose distributions to moving targets with DMLC tracking were significantly superior to those without tracking. There was no loss of treatment efficiency with DMLC tracking.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Long-Term Results of a Phase II Trial of Ultrasound-Guided Radioactive Implantation of the Prostate for Definitive Management of Localized Adenocarcinoma of the Prostate (RTOG 98-05)

Purpose: To evaluate the long-term effectiveness of transrectal ultrasound-guided permanent radioactive I{sup 125} implantation of the prostate for organ confined adenocarcinoma of the prostate compared with historical data of prostatectomy and external beam radiotherapy within a cooperative group setting. Methods and Materials: Patients accrued to this study had histologically confirmed, locally confined adenocarcinoma of the prostate clinical stage T1b, T1c, or T2a; no nodal or metastatic disease; prostate-specific antigen level of {<=}10 ng/ml; and a Gleason score of {<=}6. All patients underwent transrectal ultrasound-guided radioactive I{sup 125} seed implantation into the prostate. The prescribed dose was 145 Gy to the prostate planning target volume. Results: A total of 101 patients from 27 institutions were accrued to this protocol; by design, no single institution accrued more than 8 patients. There were 94 eligible patients. The median follow up was 8.1 years (range, 0.1-9.2 years). After 8 years, 8 patients had protocol-defined biochemical (prostate-specific antigen) failure (cumulative incidence, 8.0%); 5 patients had local failure (cumulative incidence, 5.5%); and 1 patient had distant failure (cumulative incidence, 1.1%; this patient also had biochemical failure and died of causes not related to prostate cancer). The 8-year overall survival rate was 88%. At last follow-up, no patient had died of prostate cancer or related toxicities. Three patients had maximum late toxicities of Grade 3, all of which were genitourinary. No Grade 4 or 5 toxicities were observed. Conclusions: The long-term results of this clinical trial have demonstrated that this kind of trial can be successfully completed through the RTOG and that results in terms of biochemical failure and toxicity compare very favorably with other brachytherapy published series as well as surgical and external beam radiotherapy series. In addition, the prospective, multicenter design highlights the probable generalizability of the outcomes.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Image-Guided Radiotherapy (IGRT) for Prostate Cancer Comparing kV Imaging of Fiducial Markers With Cone Beam Computed Tomography (CBCT)

Purpose: To present our single-institution experience with image-guided radiotherapy comparing fiducial markers and cone-beam computed tomography (CBCT) for daily localization of prostate cancer. Methods and Materials: From April 2007 to October 2008, 36 patients with prostate cancer received intensity-modulated radiotherapy with daily localization by use of implanted fiducials. Orthogonal kilovoltage (kV) portal imaging preceded all 1244 treatments. Cone-beam computed tomography images were also obtained before 286 treatments (23%). Shifts in the anterior-posterior (AP), superior-inferior (SI), and left-right (LR) dimensions were made from kV fiducial imaging. Cone-beam computed tomography shifts based on soft tissues were recorded. Shifts were compared by use of Bland-Altman limits of agreement. Mean and standard deviation of absolute differences were also compared. A difference of 5 mm or less was acceptable. Subsets including start date, body mass index, and prostate size were analyzed. Results: Of 286 treatments, 81 (28%) resulted in a greater than 5.0-mm difference in one or more dimensions. Mean differences in the AP, SI, and LR dimensions were 3.4 {+-} 2.6 mm, 3.1 {+-} 2.7 mm, and 1.3 {+-} 1.6 mm, respectively. Most deviations occurred in the posterior (fiducials, 78%; CBCT, 59%), superior (79%, 61%), and left (57%, 63%) directions. Bland-Altman 95% confidence intervals were -4.0 to 9.3 mm for AP, -9.0 to 5.3 mm for SI, and -4.1 to 3.9 mm for LR. The percentages of shift agreements within {+-}5 mm were 72.4% for AP, 72.7% for SI, and 97.2% for LR. Correlation between imaging techniques was not altered by time, body mass index, or prostate size. Conclusions: Cone-beam computed tomography and kV fiducial imaging are similar; however, more than one-fourth of CBCT and kV shifts differed enough to affect target coverage. This was even more pronounced with smaller margins (3 mm). Fiducial imaging requires less daily physician input, is less time-consuming, and is our preferred method for prostate image-guided radiotherapy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Magnetic Resonance Lymphography-Guided Selective High-Dose Lymph Node Irradiation in Prostate Cancer

Purpose: To demonstrate the feasibility of magnetic resonance lymphography (MRL) -guided delineation of a boost volume and an elective target volume for pelvic lymph node irradiation in patients with prostate cancer. The feasibility of irradiating these volumes with a high-dose boost to the MRL-positive lymph nodes in conjunction with irradiation of the prostate using intensity-modulated radiotherapy (IMRT) was also investigated. Methods and Materials: In 4 prostate cancer patients with a high risk of lymph node involvement but no enlarged lymph nodes on CT and/or MRI, MRL detected pathological lymph nodes in the pelvis. These lymph nodes were identified and delineated on a radiotherapy planning CT to create a boost volume. Based on the location of the MRL-positive lymph nodes, the standard elective pelvic target volume was individualized. An IMRT plan with a simultaneous integrated boost (SIB) was created with dose prescriptions of 42 Gy to the pelvic target volume, a boost to 60 Gy to the MRL-positive lymph nodes, and 72 Gy to the prostate. Results: All MRL-positive lymph nodes could be identified on the planning CT. This information could be used to delineate a boost volume and to individualize the pelvic target volume for elective irradiation. IMRT planning delivered highly acceptable radiotherapy plans with regard to the prescribed dose levels and the dose to the organs at risk (OARs). Conclusion: MRL can be used to select patients with limited lymph node involvement for pelvic radiotherapy. MRL-guided delineation of a boost volume and an elective pelvic target volume for selective high-dose lymph node irradiation with IMRT is feasible. Whether this approach will result in improved outcome for these patients needs to be investigated in further clinical studies.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Early Outcomes From Three Prospective Trials of Image-Guided Proton Therapy for Prostate Cancer

Purpose: To report early outcomes with image-guided proton therapy for prostate cancer. Methods and Materials: We accrued 211 prostate cancer patients on prospective Institutional Review Board-approved trials of 78 cobalt gray equivalent (CGE) in 39 fractions for low-risk disease, dose escalation from 78 to 82 CGE for intermediate-risk disease, and 78 CGE with concomitant docetaxel followed by androgen deprivation for high-risk disease. Minimum follow-up was 2 years. Results: One intermediate-risk patient and 2 high-risk patients had disease progression. Pretreatment genitourinary (GU) symptom management was required in 38% of patients. A cumulative 88 (42%) patients required posttreatment GU symptom management. Four transient Grade 3 GU toxicities occurred, all among patients requiring pretreatment GU symptom management. Multivariate analysis showed correlation between posttreatment GU 2+ symptoms and pretreatment GU symptom management (p < 0.0001) and age (p = 0.0048). Only 1 Grade 3+ gastrointestinal (GI) symptom occurred. The prevalence of Grade 2+ GI symptoms was 0 (0%), 10 (5%), 12 (6%), and 8 (4%) at 6, 12, 18, and 24 months, with a cumulative incidence of 20 (10%) patients at 2 years after proton therapy. Univariate and multivariate analyses showed significant correlation between Grade 2+ rectal bleeding and proctitis and the percentage of rectal wall (rectum) receiving doses ranging from 40 CGE (10 CGE) to 80 CGE. Conclusions: Early outcomes with image-guided proton therapy suggest high efficacy and minimal toxicity with only 1.9% Grade 3 GU symptoms and <0.5% Grade 3 GI toxicities.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Prospective Study of Cone-Beam Computed Tomography Image-Guided Radiotherapy for Prone Accelerated Partial Breast Irradiation

Purpose: To report setup variations during prone accelerated partial breast irradiation (APBI). Methods: New York University (NYU) 07-582 is an institutional review board-approved protocol of cone-beam computed tomography (CBCT) to deliver image-guided ABPI in the prone position. Eligible are postmenopausal women with pT1 breast cancer excised with negative margins and no nodal involvement. A total dose of 30 Gy in five daily fractions of 6 Gy are delivered to the planning target volume (the tumor cavity with 1.5-cm margin) by image-guided radiotherapy. Patients are set up prone, on a dedicated mattress, used for both simulation and treatment. After positioning with skin marks and lasers, CBCTs are performed and the images are registered to the planning CT. The resulting shifts (setup corrections) are recorded in the three principal directions and applied. Portal images are taken for verification. If they differ from the planning digital reconstructed radiographs, the patient is reset, and a new CBCT is taken. Results: 70 consecutive patients have undergone a total of 343 CBCTs: 7 patients had four of five planned CBCTs performed. Seven CBCTs (2%) required to be repeated because of misalignment in the comparison between portal and digital reconstructed radiograph image after the first CBCT. The mean shifts and standard deviations in the anterior-posterior (AP), superior-inferior (SI), and medial-lateral (ML) directions were -0.19 (0.54), -0.02 (0.33), and -0.02 (0.43) cm, respectively. The average root mean squares of the daily shifts were 0.50 (0.28), 0.29 (0.17), and 0.38 (0.20). A conservative margin formula resulted in a recommended margin of 1.26, 0.73, 0.96 cm in the AP, SI, and ML directions. Conclusion: CBCTs confirmed that the NYU prone APBI setup and treatment technique are reproducible, with interfraction variation comparable to those reported for supine setup. The currently applied margin (1.5 cm) adequately compensates for the setup variation detected.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Image-Guided Robotic Stereotactic Body Radiation Therapy for Liver Metastases: Is There a Dose Response Relationship?

Purpose: To evaluate the outcome, tolerance, and toxicity of stereotactic body radiotherapy, using image-guided robotic radiation delivery, for the treatment of patients with unresectable liver metastases. Methods and Material: Patients were treated with real-time respiratory tracking between July 2007 and April 2009. Their records were retrospectively reviewed. Metastases from colorectal carcinoma and other primaries were not necessarily confined to liver. Toxicity was evaluated using National Cancer Institute Common Criteria for Adverse Events version 3.0. Results: Forty-two patients with 62 metastases were treated with two dose levels of 40 Gy in four Dose per Fraction (23) and 45 Gy in three Dose per Fraction (13). Median follow-up was 14.3 months (range, 3-23 months). Actuarial local control for 1 and 2 years was 90% and 86%, respectively. At last follow-up, 41 (66%) complete responses and eight (13%) partial responses were observed. Five lesions were stable. Nine lesions (13%) were locally progressed. Overall survival was 94% at 1 year and 48% at 2 years. The most common toxicity was Grade 1 or 2 nausea. One patient experienced Grade 3 epidermitis. The dose level did not significantly contribute to the outcome, toxicity, or survival. Conclusion: Image-guided robotic stereotactic body radiation therapy is feasible, safe, and effective, with encouraging local control. It provides a strong alternative for patients who cannot undergo surgery.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Localization of a Portion of an Endorectal Balloon for Prostate Image-Guided Radiation Therapy Using Cone-Beam Tomosynthesis: A Feasibility Study

Purpose: To assess the feasibility of using cone-beam tomosynthesis (CBTS) to localize the air-tissue interface for the application of prostate image-guided radiation therapy using an endorectal balloon for immobilization and localization. Methods and Materials: A Feldkamp-David-Kress-based CBTS reconstruction was applied to selected sets of cone-beam computed tomography (CBCT) projection data to simulate volumetric imaging achievable from tomosynthesis for a limited range of scan angles. Projection data were calculated from planning CT images of 10 prostate cancer patients treated with an endorectal balloon, as were experimental CBCT projections for a pelvic phantom in two patients. More than 50 points at the air-tissue interface were objectively identified by an intensity-based interface-finding algorithm. Using three-dimensional point sets extracted from CBTS images compared with points extracted from corresponding CBCT images, the relative shift resulting from a reduced scan angle was determined. Because the CBCT and CBTS images were generated from the same projection data set, shift identified was presumed to be due to distortions introduced by the tomosynthesis technique. Results: Scans of {>=}60 Degree-Sign were shown to be able to localize an air-tissue interface near the isocenter with accuracy on the order of a millimeter. The accuracy was quantified in terms of the mean discrepancy as a function of reconstruction angle. Conclusion: This work provides an understanding of the effect of scan angle used in localization of a portion of an endorectal balloon by means of CBTS. CBTS with relatively small scan angles is capable of accurately localizing an extended interface near the isocenter and may provide clinically relevant measurements to guide IGRT treatments while reducing imaging radiation to the patient.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Dose-Guided Radiotherapy: Potential Benefit of Online Dose Recalculation for Stereotactic Lung Irradiation in Patients With Non-Small-Cell Lung Cancer

Purpose: To determine whether dose-guided radiotherapy (i.e., online recalculation and evaluation of the actual dose distribution) can improve decision making for lung cancer patients treated with stereotactic body radiotherapy. Methods and Materials: For this study 108 cone-beam computed tomography (CBCT) scans of 10 non-small-cell lung cancer patients treated with stereotactic body radiotherapy were analyzed retrospectively. The treatment plans were recalculated on the CBCT scans. The V{sub 100%} of the internal target volume (ITV) and D{sub max} of the organs at risk (OARs) were analyzed. Results from the recalculated data were compared with dose estimates for target and OARs by superposition of the originally planned dose distribution on CBCT geometry (i.e., the original dose distribution was assumed to be spatially invariant). Results: Before position correction was applied the V{sub 100%} of the ITV was 100% in 65% of the cases when an ITV-PTV margin of 5 mm was used and 52% of the cases when a margin of 3 mm was used. After position correction, the difference of D{sub max} in the OARs with respect to the treatment plan was within 5% in the majority of the cases. When the dose was not recalculated but estimated assuming an invariant dose distribution, clinically relevant errors occurred in both the ITV and the OARs. Conclusion: Dose-guided radiotherapy can be used to determine the actual dose in OARs when the target has moved with respect to the OARs. When the workflow is optimized for speed, it can be used to prevent unnecessary position corrections. Estimating the dose by assuming an invariant dose instead of recalculation of the dose gives clinically relevant errors.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Predictors of Toxicity After Image-guided High-dose-rate Interstitial Brachytherapy for Gynecologic Cancer

Purpose: To identify predictors of grade 3-4 complications and grade 2-4 rectal toxicity after three-dimensional image-guided high-dose-rate (HDR) interstitial brachytherapy for gynecologic cancer. Methods and Materials: Records were reviewed for 51 women (22 with primary disease and 29 with recurrence) treated with HDR interstitial brachytherapy. A single interstitial insertion was performed with image guidance by computed tomography (n = 43) or magnetic resonance imaging (n = 8). The median delivered dose in equivalent 2-Gy fractions was 72.0 Gy (45 Gy for external-beam radiation therapy and 24 Gy for brachytherapy). Toxicity was reported according to the Common Toxicity Criteria for Adverse Events. Actuarial toxicity estimates were calculated by the Kaplan-Meier method. Results: At diagnosis, the median patient age was 62 years and the median tumor size was 3.8 cm. The median D90 and V100 were 71.4 Gy and 89.5%; the median D2cc for the bladder, rectum, and sigmoid were 64.6 Gy, 61.0 Gy, and 52.7 Gy, respectively. The actuarial rates of all grade 3-4 complications at 2 years were 20% gastrointestinal, 9% vaginal, 6% skin, 3% musculoskeletal, and 2% lymphatic. There were no grade 3-4 genitourinary complications and no grade 5 toxicities. Grade 2-4 rectal toxicity was observed in 10 patients, and grade 3-4 complications in 4; all cases were proctitis with the exception of 1 rectal fistula. D2cc for rectum was higher for patients with grade 2-4 (68 Gy vs 57 Gy for grade 0-1, P=.03) and grade 3-4 (73 Gy vs 58 Gy for grade 0-2, P=.02) rectal toxicity. The estimated dose that resulted in a 10% risk of grade 2-4 rectal toxicity was 61.8 Gy (95% confidence interval, 51.5-72.2 Gy). Discussion: Image-guided HDR interstitial brachytherapy results in acceptable toxicity for women with primary or recurrent gynecologic cancer. D2cc for the rectum is a reliable predictor of late rectal complications. Three-dimensional-based treatment planning should be performed to ensure adequate tumor coverage while minimizing the D2cc to the rectum.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Five-Year Outcomes from 3 Prospective Trials of Image-Guided Proton Therapy for Prostate Cancer

Purpose: To report 5-year clinical outcomes of 3 prospective trials of image-guided proton therapy for prostate cancer. Methods and Materials: A total of 211 prostate cancer patients (89 low-risk, 82 intermediate-risk, and 40 high-risk) were treated in institutional review board-approved trials of 78 cobalt gray equivalent (CGE) in 39 fractions for low-risk disease, 78 to 82 CGE for intermediate-risk disease, and 78 CGE with concomitant docetaxel therapy followed by androgen deprivation therapy for high-risk disease. Toxicities were graded according to Common Terminology Criteria for Adverse Events (CTCAE), version 3.0. Median follow-up was 5.2 years. Results: Five-year rates of biochemical and clinical freedom from disease progression were 99%, 99%, and 76% in low-, intermediate-, and high-risk patients, respectively. Actuarial 5-year rates of late CTCAE, version 3.0 (or version 4.0) grade 3 gastrointestinal and urologic toxicity were 1.0% (0.5%) and 5.4% (1.0%), respectively. Median pretreatment scores and International Prostate Symptom Scores at >4 years posttreatment were 8 and 7, 6 and 6, and 9 and 8, respectively, among the low-, intermediate-, and high-risk patients. There were no significant changes between median pretreatment summary scores and Expanded Prostate Cancer Index Composite scores at >4 years for bowel, urinary irritative and/or obstructive, and urinary continence. Conclusions: Five-year clinical outcomes with image-guided proton therapy included extremely high efficacy, minimal physician-assessed toxicity, and excellent patient-reported outcomes. Further follow-up and a larger patient experience are necessary to confirm these favorable outcomes.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

MRI-Guided High–Dose-Rate Intracavitary Brachytherapy for Treatment of Cervical Cancer: The University of Pittsburgh Experience

Purpose: Image-based brachytherapy is increasingly used for gynecologic malignancies. We report early outcomes of magnetic resonance imaging (MRI)-guided brachytherapy. Methods and Materials: Consecutive patient cases with FIGO stage IB1 to IVA cervical cancer treated at a single institution were retrospectively reviewed. All patients received concurrent cisplatin with external beam radiation therapy along with interdigitated high–dose-rate intracavitary brachytherapy. Computed tomography or MRI was completed after each application, the latter acquired for at least 1 fraction. High-risk clinical target volume (HRCTV) and organs at risk were identified by Groupe Européen de Curiethérapie and European SocieTy for Radiotherapy and Oncology guidelines. Doses were converted to equivalent 2-Gy doses (EQD{sub 2}) with planned HRCTV doses of 75 to 85 Gy. Results: From 2007 to 2013, 128 patients, median 52 years of age, were treated. Predominant characteristics included stage IIB disease (58.6%) with a median tumor size of 5 cm, squamous histology (82.8%), and no radiographic nodal involvement (53.1%). Most patients (67.2%) received intensity modulated radiation therapy (IMRT) at a median dose of 45 Gy, followed by a median brachytherapy dose of 27.5 Gy (range, 25-30 Gy) in 5 fractions. At a median follow up of 24.4 months (range, 2.1-77.2 months), estimated 2-year local control, disease-free survival, and cancer-specific survival rates were 91.6%, 81.8%, and 87.6%, respectively. Predictors of local failure included adenocarcinoma histology (P<.01) and clinical response at 3 months (P<.01). Among the adenocarcinoma subset, receiving HRCTV D{sub 90} EQD{sub 2} ≥84 Gy was associated with improved local control (2-year local control rate 100% vs 54.5%, P=.03). Grade 3 or greater gastrointestinal or genitourinary late toxicity occurred at a 2-year actuarial rate of 0.9%. Conclusions: This study constitutes one of the largest reported series of MRI-guided brachytherapy in North America, demonstrating excellent local control with acceptable morbidity. Dose escalation may be warranted when feasible for adenocarcinomas to offset the risk of local failure.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Magnetic Resonance Imaging–Guided versus Surrogate-Based Motion Tracking in Liver Radiation Therapy: A Prospective Comparative Study

Purpose: This study applied automatic feature detection on cine–magnetic resonance imaging (MRI) liver images in order to provide a prospective comparison between MRI-guided and surrogate-based tracking methods for motion-compensated liver radiation therapy. Methods and Materials: In a population of 30 subjects (5 volunteers plus 25 patients), 2 oblique sagittal slices were acquired across the liver at high temporal resolution. An algorithm based on scale invariant feature transform (SIFT) was used to extract and track multiple features throughout the image sequence. The position of abdominal markers was also measured directly from the image series, and the internal motion of each feature was quantified through multiparametric analysis. Surrogate-based tumor tracking with a state-of-the-art external/internal correlation model was simulated. The geometrical tracking error was measured, and its correlation with external motion parameters was also investigated. Finally, the potential gain in tracking accuracy relying on MRI guidance was quantified as a function of the maximum allowed tracking error. Results: An average of 45 features was extracted for each subject across the whole liver. The multi-parametric motion analysis reported relevant inter- and intrasubject variability, highlighting the value of patient-specific and spatially-distributed measurements. Surrogate-based tracking errors (relative to the motion amplitude) were were in the range 7% to 23% (1.02-3.57mm) and were significantly influenced by external motion parameters. The gain of MRI guidance compared to surrogate-based motion tracking was larger than 30% in 50% of the subjects when considering a 1.5-mm tracking error tolerance. Conclusions: Automatic feature detection applied to cine-MRI allows detailed liver motion description to be obtained. Such information was used to quantify the performance of surrogate-based tracking methods and to provide a prospective comparison with respect to MRI-guided radiation therapy, which could support the definition of patient-specific optimal treatment strategies.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Computed Tomography Number Changes Observed During Computed Tomography–Guided Radiation Therapy for Head and Neck Cancer

Purpose: To investigate CT number (CTN) changes in gross tumor volume (GTV) and organ at risk (OAR) according to daily diagnostic-quality CT acquired during CT-guided intensity modulated radiation therapy for head and neck cancer (HNC) patients. Methods and Materials: Computed tomography scans acquired using a CT-on-rails during daily CT-guided intensity modulated radiation therapy for 15 patients with stage II to IVa squamous cell carcinoma of the head and neck were analyzed. The GTV, parotid glands, spinal cord, and nonspecified tissue were generated on each selected daily CT. The changes in CTN distributions and the mean and mode values were collected. Pearson analysis was used to assess the correlation between the CTN change, organ volume reduction, and delivered radiation dose. Results: Volume and CTN changes for GTV and parotid glands can be observed during radiation therapy delivery for HNC. The mean (±SD) CTNs in GTV and ipsi- and contralateral parotid glands were reduced by 6 ± 10, 8 ± 7, and 11 ± 10 Hounsfield units, respectively, for all patients studied. The mean CTN changes in both spinal cord and nonspecified tissue were almost invisible (<2 Hounsfield units). For 2 patients studied, the absolute mean CTN changes in GTV and parotid glands were strongly correlated with the dose delivered (P<.001 and P<.05, respectively). For the correlation between CTN reductions and delivered isodose bins for parotid glands, the Pearson coefficient varied from −0.98 (P<.001) in regions with low-dose bins to 0.96 (P<.001) in high-dose bins and were patient specific. Conclusions: The CTN can be reduced in tumor and parotid glands during the course of radiation therapy for HNC. There was a fair correlation between CTN reduction and radiation doses for a subset of patients, whereas the correlation between CTN reductions and volume reductions in GTV and parotid glands were weak. More studies are needed to understand the mechanism for the radiation-induced CTN changes.

62 RADIOLOGY AND NUCLEAR MEDICINE↗