Monitoring, Reporting, and Verification Plan (MRV)- Meeting EPA Guidelines for GHGRP and Subpart RR

This report summarizes the process and work completed to develop and successfully submit an MRV plan to EPA. This work used the lessons learned from various MRCSP tasks to demonstrate the geologic understanding of the Niagaran reefs, successful monitoring and accounting methodologies, understanding of potential risks and leakage pathways, and mass balance of CO2 baseline and net storage. The plan currently encompasses 10 reefs and also provides a reporting plan for future reef development.

accounting↗

Testing guidelines for technetium-99 absorption on activated carbon

CH2M HILL Plateau Remediation Company (CHPRC) is currently evaluating the potential use of activated carbon adsorption for removing technetium-99 from groundwater as a treatment method for the Hanford Site's 200 West Area groundwater pump-and-treat system. The current pump-and-treat system design will include an ion-exchange (IX) system for selective removal of technetium-99 from selected wells prior to subsequent treatment of the water in the central treatment system. The IX resin selected for technetium-99 removal is Purolite A530E.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Guidelines for Estimating Unmetered Industrial Water Use

The document provides a methodology to estimate unmetered industrial water use for evaporative cooling systems, steam generating boiler systems, batch process applications, and wash systems. For each category standard mathematical relationships are summarized and provided in a single resource to assist Federal agencies in developing an initial estimate of their industrial water use. The approach incorporates industry norms, general rules of thumb, and industry survey information to provide methodologies for each section.

99 GENERAL AND MISCELLANEOUS↗

Strategy Guideline: Accurate Heating and Cooling Load Calculations

This guide presents the key criteria required to create accurate heating and cooling load calculations and offers examples of the implications when inaccurate adjustments are applied to the HVAC design process. The guide shows, through realistic examples, how various defaults and arbitrary safety factors can lead to significant increases in the load estimate. Emphasis is placed on the risksincurred from inaccurate adjustments or ignoring critical inputs of the load calculation.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Restaurant Energy Use Benchmarking Guideline

A significant operational challenge for food service operators is defining energy use benchmark metrics to compare against the performance of individual stores. Without metrics, multiunit operators and managers have difficulty identifying which stores in their portfolios require extra attention to bring their energy performance in line with expectations. This report presents a method wherebymultiunit operators may use their own utility data to create suitable metrics for evaluating their operations.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Advanced Strategy Guideline: Air Distribution Basics and Duct Design

This report discusses considerations for designing an air distribution system for an energy efficient house that requires less air volume to condition the space. Considering the HVAC system early in the design process will allow adequate space for equipment and ductwork and can result in cost savings. Principles discussed that will maximize occupant comfort include delivery of the proper amountof conditioned air for appropriate temperature mixing and uniformity without drafts, minimization of system noise, the impacts of pressure loss, efficient return air duct design, and supply air outlet placement, as well as duct layout, materials, and sizing.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Measure Guideline: Sealing and Insulating of Ducts in Existing Homes

This document begins with a discussion on potential cost and performance benefits of duct sealing and insulating. It continues with a review of typical duct materials and components and the overall procedures for assessing and improving the duct system.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Measure Guideline: Water Management at Tub and Shower Assemblies

Due to the high concentrations of water and the consequential risk of water damage to the home's structure a comprehensive water management system is imperative to protect the building assemblies underlying the finish surround of tub and shower areas. This guide shows how to install fundamental waterproofing strategies to prevent water related issues at shower and tub areas.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Suggested guidelines for anti-islanding screening

As increasing numbers of photovoltaic (PV) systems are connected to utility systems, distribution engineers are becoming increasingly concerned about the risk of formation of unintentional islands. Utilities desire to keep their systems secure, while not imposing unreasonable burdens on users wishing to connect PV. However, utility experience with these systems is still relatively sparse, so distribution engineers often are uncertain as to when additional protective measures, such as direct transfer trip, are needed to avoid unintentional island formation. In the absence of such certainty, utilities must err on the side of caution, which in some cases may lead to the unnecessary requirement of additional protection. The purpose of this document is to provide distribution engineers and decision makers with guidance on when additional measures or additional study may be prudent, and also on certain cases in which utilities may allow PV installations to proceed without additional study because the risk of an unintentional island is extremely low. The goal is to reduce the number of cases of unnecessary application of additional protection, while giving utilities a basis on which to request additional study in cases where it is warranted.

14 SOLAR ENERGY↗

Revised Guidelines for using Cellulose Degradation Product-Impacted Kd Values for Performance Assessments and Composite Analyses

Cellulosic materials include wood, paper, rags, and cardboard products. These materials are co-disposed with radiological waste at the Savannah River Site's (SRS) E-Area Low-Level Waste Facility (ELLWF). Cellulosic materials readily degrade in the environment to form cellulose degradation products (CDP) that will partition to the sediment or remain mobile in the groundwater. Savannah River National Lab (SRNL) has conducted studies to estimate the impact of CDP on radionuclide sorption to SRS sediments (Kd values). It was found that CDP impact on radionuclide sorption varies with radionuclide and CDP concentration. Furthermore, it was found that the amount of carbon (C) in the system could increase or decrease Kd values with respect to the base case of when no CDP was added. Throughout the expected pH range of the ELLWF, a low concentration of CDP in the system would increase Kd values (because C would sorb to the sediment and provide more exchange sites for radionuclides to sorb), whereas greater concentrations of CDP (≥20 mg/L C) would decrease Kd values (because C would remain in solution and complex the radionuclide and not permit the radionuclide to sorb to the sediment). A review of >230 dissolved organic carbon (DOC) groundwater concentrations in the Old Radioactive Waste Burial Ground (ORWBG) at the SRS indicated that the average DOC concentration, a gross measure of CDP, was 5 mg/L C. At approximately this DOC concentration, the laboratory studies demonstrated that no anions (Tc, I, or Se) or cations (Ni, Sr, Ce, Eu, Zr, or Th) have decreased sorption in the presence of carbon (an analogue for CDP).

09 BIOMASS FUELS↗

INFL Guideline on Secondary Ion Mass Spectrometry (SIMS)

Secondary Ion Mass Spectrometry (SIMS) is used for elemental and isotopic analysis of solid samples. The greatest strength of SIMS is the ability to analyze very small areas (as small as 50 nm using the CAMECA NanoSIMS, for example) and to generate high-spatial resolution maps of the distribution of elements and isotopes within the sample. The measurement of the isotopic composition of sample is usually straightforward, only requiring the analysis of the sample and that of an isotopic reference material for determination of the mass bias of the instrument. Quantification of elements, however, involves the analysis of matrix matched standards for the determination of the relative sensitivity factor (a function of both the element to be analyzed and the matrix). SIMS is commonly used in nuclear forensics for exploring the heterogeneity of the material on fine spatial scale.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Measure Guideline: Combination Forced-Air Space and Tankless Domestic Hot Water Heating Systems

This document describes design and application guidance for combination space and tankless domestic hot water heating systems (combination systems) used in residential buildings, based on field evaluation, testing, and industry meetings conducted by Building Science Corporation. As residential building enclosure improvements continue to drive heating loads down, using the same water heatingequipment for both space heating and domestic water heating becomes attractive from an initial cost and space-saving perspective. This topic is applicable to single- and multi-family residential buildings, both new and retrofitted.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Measure Guideline: Wall Air Sealing and Insulation Methods in Existing Homes; An Overview of Opportunity and Process

This guide provides renovators and retrofit contractors an overview of considerations when including wall air sealing and insulation in an energy retrofit project. It also outlines the potential project risks, various materials for insulating, possible field inspections needed, installation procedures, as well as the benefits and drawbacks. The purpose of this document is to provide the outline of the overview and process of insulating and air sealing walls so that home retrofit professionals can identify approaches to air sealing and insulation measures.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Guidelines for beamline and front-end radiation shielding design at the Advanced Photon Source

Shielding for the APS will be such that the individual radiation worker dose will be as low as reasonably achievable (ALARA). The ALARA goals for the APS are to keep the total of the work-related radiation exposure (exposure coming from other than natural or medical sources) as far below 500 person-mrem per year, collective total effective dose equivalent, as reasonably achievable.

Fernandez, P.↗

Strategy Guideline: Mitigation of Retrofit Risk Factors

The Alliance for Residential Building Innovation (ARBI) is currently developing strategies designed to promote and achieve increased energy savings and promote upgrades in the residential retrofit sector. These strategies are targeted to retrofit program managers, retrofit contractors, policy makers, academic researchers, and non-governmental organizations. This report focuses on four key areas to promote home energy upgrades: fostering accurate energy savings projections; understanding consumer perceptions for energy savings; measuring energy savings, and ensuring quality control for retrofit installations.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Strategy Guideline: Partnering for High Performance Homes

High performance houses require a high degree of coordination and have significant interdependencies between various systems in order to perform properly, meet customer expectations, and minimize risks for the builder. Responsibility for the key performance attributes is shared across the project team and can be well coordinated through advanced partnering strategies. For high performance homes, traditional partnerships need to be matured to the next level and be expanded to all members of the project team including trades, suppliers, manufacturers, HERS raters, designers, architects, and building officials as appropriate. In an environment where the builder is the only source of communication between trades and consultants and where relationships are, in general, adversarial as opposed to cooperative, the chances of any one building system to fail are greater. Furthermore, it is much harder for the builder to identify and capitalize on synergistic opportunities. Partnering can help bridge the cross-functional aspects of the systems approach and achieve performance-based criteria. Critical success factors for partnering include support from top management, mutual trust, effective and open communication, effective coordination around common goals, team building, appropriate use of an outside facilitator, a partnering charter progress toward common goals, an effective problem-solving process, long-term commitment, continuous improvement, and a positive experience for all involved. This guide is intended for use by all parties associated with the design and construction of high performance homes. It serves as a starting point and features initial tools and resources for teams to start collaborating to continually improve the energy efficiency and durability of new houses.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Measure Guideline: Steam System Balancing and Tuning for Multifamily Residential Buildings

This report was written as a resource for professionals involved in multifamily audits, retrofit delivery, and program design, as well as for building owners and contractors. It is intended to serve as a guide for those looking to evaluate and improve the efficiency and operation of one-pipe steam heating systems. In centrally heated multifamily buildings with steam or hydronic systems, the cost of heat for tenants is typically absorbed into the owner's operating costs. Highly variable and rising energy costs have placed a heavy burden on landlords. In the absence of well-designed and relevant efficiency efforts, increased operating costs would be passed on to tenants who often cannot afford those increases. Misinvestment is a common problem with older heating systems -- multiple contractors may inadequately or inappropriately upgrade parts of systems and reduce system functionality and efficiency, or the system has not been properly maintained.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗