Search NASA⌕ Search

SEARCH · Search NASA

Results for “high spatial resolution”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 721 records · Page 40

Photoemission electron microscopy using extreme ultraviolet attosecond pulse trains

We report the first experiments carried out on a new imaging setup, which combines the high spatial resolution of a photoemission electron microscope (PEEM) with the temporal resolution of extreme ultraviolet (XUV) attosecond pulse trains. The very short pulses were provided by high-harmonic generation and used to illuminate lithographic structures and Au nanoparticles, which, in turn, were imaged with a PEEM resolving features below 300 nm. We argue that the spatial resolution is limited by the lack of electron energy filtering in this particular demonstration experiment. Problems with extensive space charge effects, which can occur due to the low probe pulse repetition rate and extremely short duration, are solved by reducing peak intensity while maintaining a sufficient average intensity to allow imaging. Finally, a powerful femtosecond infrared (IR) beam was combined with the XUV beam in a pump-probe setup where delays could be varied from subfemtoseconds to picoseconds. The IR pump beam could induce multiphoton electron emission in resonant features on the surface. The interaction between the electrons emitted by the pump and probe pulses could be observed.

74 ATOMIC AND MOLECULAR PHYSICS↗

First results from the J-TEXT high-resolution three-wave polarimeter-interferometer

A laser-based far-infrared polarimeter-interferometer system utilizing the three-wave technique has been implemented on the J-TEXT tokamak. The polarimeter determines the Faraday effect by measuring the phase difference between two collinear, counter-rotating, circularly polarized laser beams. The first results of the polarimeter-interferometer designed for J-TEXT have been obtained in the most recent J-TEXT experimental campaign. Simultaneous polarimetric and interferometric measurement is achieved, with phase resolution up to 0.1 Degree-Sign , at bandwidth of 50 kHz. The temporal resolution, which is dependent on the laser's frequency offset, is {approx}1 {mu}s. Continual spatial measurement covering 45 cm (80% of the plasma cross-section) is realized by utilizing 1D parabolic beam expansion optics. Three initial test chords are installed and future plans call for expansion up to 30 chords with 1.5 cm chord spacing, providing high spatial resolution for measurement of electron density and current density profiles. Reliability of both polarimetric and interferometric measurement is confirmed by comparison with computation and data from a hydrocyanic acid (HCN) interferometer. With the high temporal and phase resolution, perturbations associated with the sawtooth cycle and MHD activity have been observed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Preparation and Characterization of PdFe Nanoleaves as Electrocatalysts for Oxygen Reduction Reaction

Novel PdFe-nanoleaves (NLs) have been prepared through a wet chemistry-based solution phase reduction synthesis route. High-resolution transmission electron microscopy (HR-TEM) and scanning transmission electron microscopy (S/TEM) coupled with high-spatial-resolution compositional analysis clearly show this newly-developed structure is assembled from Pd-rich nanowires (NWs) surrounded by Fe-rich sheets. The Pd-NWs have a diameter in the range of 1.8-2.3 nm and a large electrochemical surface area of >50 m2/g. Their length (30 - 100 nm) and morphology can be tuned by altering the nanostructure synthesis conditions and the Fe amount in the NLs. With increasing Fe content, thinner and longer sheet-enveloped nanowires can be prepared. The side surfaces of Pd-NWs observed by HR-TEM are predominantly Pd (111) facets, while the tips and ends are Pd (110) and Pd (100) facets. By etching away the enveloping Fe-rich sheets using an organic acid, the Pd-rich NWs are exposed on the surfaces of the nanoleaves, and they demonstrate high reactivity towards electrocatalytic reduction of oxygen in a 0.1 M NaOH electrolyte, i.e., 3.0 increase in the specific activity and 2.7 increase in the mass activity compared with a commercial Pt/C catalyst (at 0 V vs. Hg/HgO). The electrocatalytic activity enhancement can be attributed to the unique nanoleave structure that provides more Pd (111) facets, a large surface area, and more resistance to Pd oxide formation.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

High resolution main-ion charge exchange spectroscopy in the DIII-D H-mode pedestal

A new high spatial resolution main-ion (deuterium) charge-exchange spectroscopy system covering the tokamak boundary region has been installed on the DIII-D tokamak. Sixteen new edge main-ion charge-exchange recombination sightlines have been combined with nineteen impurity sightlines in a tangentially viewing geometry on the DIII-D midplane with an interleaving design that achieves 8 mm inter-channel radial resolution for detailed profiles of main-ion temperature, velocity, charge-exchange emission, and neutral beam emission. At the plasma boundary, we find a strong enhancement of the main-ion toroidal velocity that exceeds the impurity velocity by a factor of two. Furthermore, the unique combination of experimentally measured main-ion and impurity profiles provides a powerful quasi-neutrality constraint for reconstruction of tokamak H-mode pedestals.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

High spatial and energy resolution electron energy loss spectroscopy of the magnetic and electric excitations in plasmonic nanorod oligomers

We leverage the high spatial and energy resolution of monochromated aberration-corrected scanning transmission electron microscopy to study the hybridization of cyclic assemblies of plasmonic gold nanorods. Detailed experiments and simulations elucidate the hybridization of the coupled long-axis dipole modes into collective magnetic and electric dipole plasmon resonances. We resolve the magnetic dipole mode in these closed loop oligomers with electron energy loss spectroscopy and confirm the mode assignment with its characteristic spectrum image. The energy splitting of the magnetic mode and antibonding modes increases with the number of polygon edges (n). For the n=3-6 oligomers studied, optical simulations using normal incidence and s-polarized oblique incidence show the respective electric and magnetic modes’ extinction efficiencies are maximized in the n=4 arrangement.

47 OTHER INSTRUMENTATION↗

High-Resolution 3D Acoustic Borehole Integrity Monitoring (Research Performance Progress Report Q2 2021)

Real-time, in-situ, high spatial resolution (sub-cm) imaging of the near-borehole environment would revolutionize wellbore diagnostics and integrity assessment by direct observation of defects. It is becoming increasingly apparent, that better understanding of the near-wellbore environment is required to meet the safety and operational needs in challenging environments such as those present in subsurface energy extraction (geothermal) and storage (CO2 sequestration) applications. Therefore, it is important to have a more robust ability to image the near-borehole and reliably detect defects. It was proposed to further develop and improve our advanced 3D imaging system to evaluate casing defects (e.g. corrosion) and cement quality in either open- or cased-borehole with the ultimate goal to develop a commercially deployable technology. The system consists of a unique acoustic source (LANL) and advanced inversion techniques for image processing (LANL, ORNL). This system will provide comprehensive borehole integrity monitoring with improved resolution over existing techniques. As an application of this imaging system, we will characterize the effectiveness of next-generation wellbore completion technology (NETL, SNL), and will demonstrate that, unlike current technology, the proposed approach can successfully characterize foamed cements.

15 GEOTHERMAL ENERGY↗

Improved Cloud and Snow Screening in MAIAC Aerosol Retrievals Using Spectral and Spatial Analysis

An improved cloud/snow screening technique in the Multi-Angle Implementation of Atmospheric Correction (MAIAC) algorithm is described. It is implemented as part of MAIAC aerosol retrievals based on analysis of spectral residuals and spatial variability. Comparisons with AERONET aerosol observations and a large-scale MODIS data analysis show strong suppression of aerosol optical thickness outliers due to unresolved clouds and snow. At the same time, the developed filter does not reduce the aerosol retrieval capability at high 1 km resolution in strongly inhomogeneous environments, such as near centers of the active fires. Despite significant improvement, the optical depth outliers in high spatial resolution data are and will remain the problem to be addressed by the application-dependent specialized filtering techniques.

Lyapustin, A.↗

Compact x-ray microradiograph for in situ imaging of solidification processes: Bringing in situ x-ray micro-imaging from the synchrotron to the laboratory

A laboratory based high resolution x-ray radiograph was developed for the investigation of solidification dynamics in alloys. It is based on a low-power microfocus x-ray tube and is potentially appropriate for x-ray diagnostics in space. The x-ray microscope offers a high spatial resolution down to approximately 5 {mu}m. Dynamic processes can be resolved with a frequency of up to 6 Hz. In reference experiments, the setup was optimized to yield a high contrast for AlCu-alloys. With samples of about 150 {mu}m thickness, high quality image sequences of the solidification process were obtained with high resolution in time and space.

36 MATERIALS SCIENCE↗

Using the Atmospheric Radiation Measurement (ARM) Datasets to Evaluate Climate Models in Simulating Diurnal and Seasonal Variations of Tropical Clouds

We use the long-term Atmospheric Radiation Measurement (ARM) datasets collected at the three Tropical Western Pacific (TWP) sites as a tropical testbed to evaluate the ability of the Community Atmosphere Model (CAM5) to simulate the various types of clouds, their seasonal and diurnal variations, and their impact on surface radiation. We conducted a series of CAM5 simulations at various horizontal grid spacing (around 2°, 1°, 0.5°, and 0.25°) with meteorological constraints from reanalysis. Model biases in the seasonal cycle of cloudiness are found to be weakly dependent on model resolution. Positive biases (up to 20%) in the annual mean total cloud fraction appear mostly in stratiform ice clouds. Higher-resolution simulations do reduce the positive bias in the frequency of ice clouds, but they inadvertently increase the negative biases in convective clouds and low-level liquid clouds, leading to a positive bias in annual mean shortwave fluxes at the sites, as high as 65 W m-2 in the 0.25° simulation. Such resolution-dependent biases in clouds can adversely lead to biases in ambient thermodynamic properties and, in turn, feedback on clouds. Both the CAM5 model and ARM observations show distinct diurnal cycles in total, stratiform and convective cloud fractions; however, they are out-of-phase by 12 hours and the biases vary by site. Our results suggest that biases in deep convection affect the vertical distribution and diurnal cycle of stratiform clouds through the transport of vapor and/or the detrainment of liquid and ice. We also found that the modelled gridmean surface longwave fluxes are systematically larger than site measurements when the grid that the ARM sites reside in is partially covered by ocean. The modeled longwave fluxes at such sites also lack a discernable diurnal cycle because the ocean part of the grid is warmer and less sensitive to radiative heating/cooling compared to land. Higher spatial resolution is more helpful is this regard. Our testbed approach can be easily adapted for the evaluation of new parameterizations being developed for CAM5 or other global or regional model simulations at high spatial resolutions.

Wang, Hailong↗

A micron resolution optical scanner for characterization of silicon detectors

The emergence of high position resolution (∼10 μm) silicon detectors in recent times have highlighted the urgent need for the development of new automated optical scanners of micron level resolution suited for characterizing microscopic features of these detectors. More specifically, for the newly developed silicon photo-multipliers (SiPM) that are compact, possessing excellent photon detection efficiency with gain comparable to photo-multiplier tube. In a short time, since their invention the SiPMs are already being widely used in several high-energy physics and astrophysics experiments as the photon readout element. The SiPM is a high quantum efficiency, multi-pixel photon counting detector with fast timing and high gain. The presence of a wide variety of photo sensitive silicon detectors with high spatial resolution requires their performance evaluation to be carried out by photon beams of very compact spot size. We have designed a high resolution optical scanner that provides a monochromatic focused beam on a target plane. The transverse size of the beam was measured by the knife-edge method to be 1.7 μm at 1 − σ level. Since the beam size was an order of magnitude smaller than the typical feature size of silicon detectors, this optical scanner can be used for selective excitation of these detectors. The design and operational details of the optical scanner, high precision programmed movement of target plane (0.1 μm) integrated with general purpose data acquisition system developed for recording static and transient response photo sensitive silicon detector are reported in this paper. Entire functionality of scanner is validated by using it for selective excitation of individual pixels in a SiPM and identifying response of active and dead regions within SiPM. Results from these studies are presented in this paper.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A technique for determining cloud free vs cloud contaminated pixels in satellite imagery

Since the first earth orbiting satellite sent pictures of the earth back to them, atmospheric scientists have been focused on the possibilities of using that information as both a forecasting tool and as a meteorological research tool. With the latest generation of Geostationary Operational Environmental Satellites (GOES) now entering service, that view of the earth yields views at a frequency and resolution never before available. These satellites have imagers with a five band multi-spectral capability with high spatial resolution. In addition, the sounder has eighteen thermal infrared (IR) channels plus one low-resolution visible band. With a resolution as small as one kilometer, GOES provides scientists with a powerful eye on the atmosphere. Menzel and Purdom (1994) detail both the imager and sounder capability as well as other systems on the GOES satellites. Immediately apparent in the visible channel are the patterns of clouds swirling over both oceans and continents. These clouds range in size from huge planetary systems covering thousands of kilometers to puffy fair weather cumulus clouds on the order of half a kilometer in size. With the IR sensors temperature patterns are observed. High clouds appear very cold, while low stratus field show temperatures near that of the surface. The surface, in turn, generally appears warmer than the clouds. It would seem then a simple manner to determine cloud and surface temperature from the imagery, but such is not the case. While most of the atmospheric constituents are well mixed and homogeneous, water vapor is not. The water molecule, because of its unique structure and vibration modes, affects the transmittance of the atmosphere most notably in the infrared regions. There are regions of the IR spectrum where water vapor acts as a strong absorber, and at others it is nearly transparent. The transparent wavelengths are called windows, and one such window occurs at 11.2 microns. Adjacent to this window at 12.7 microns which is strongly absorbed by water vapor. These two wavelengths form what is known as a split window, the utility of which was used. Using the linearized form of the radiative transfer equation, they were able to use the split window to determine the amount of water vapor present in the atmosphere. Jedlovec developed the physical split-window (PSW) technique which determines the integrated water content (IWC). The PSW method using Visible Infrared Spin Scan Radiometer (VISSR) Atmospheric Sounder (VAS) found on the older versions of the GOES satellites was used. Recently, Jedlovec and colleagues have been attempting to apply the PSW method using full disk IR imagery obtained by the new generation of GOES satellites. IWC is essential for improved analysis and prediction of convective storms which have been observed to develop in regions of both strong and rapidly evolving moisture gradients. It has also been used in the prediction of clouds and precipitation.

Wohlman, Richard A.↗

An Analysis of Gravity-Field Estimation Based on Intersatellite Dual-1-Way Biased Ranging

The GRACE (Gravity Recovery And Climate Experiment) mission is designed to make global, highly accurate measurements of the Earth's gravity field with high spatial resolution. Ancillary GPS occultation measurements are also to be carried out for atmospheric monitoring. In the dual-1-way biased ranging of this mission, the range between two satellites separated by 100 to 200 km in nearly polar, coplanar, circular orbits, is measured to very high precision, to within an additive constant, through the exchange of K- and Ka-band sinusoidal signals. Such biased ranging data, along with GPS L-band range and phase data, can be processed and fit over successive multiday intervals to obtain accurate estimates of the Earth's gravity field. This report approximately models and analyzes this process, from the generation of the RF signals at the two satellites through the extraction of the geopotential. The steps include generation of the transmitted signals, processing the received signals to extract high-rate baseband phase, carrying out a dual-1-way combination of baseband phase to extract high-rate biased range for each band, combining K- and Ka-band ranges to correct for the ionosphere effect, and processing the resulting high-rate biased range values to extract three types of reduced-rate observables: biased range, range rate and range acceleration. The version of dual-1-way biased ranging developed by this report improves upon previous versions in a number of ways: highly accurate satellite-timetag corrections derived from concurrent GPS data, better baseband phase extraction using highly digital processing, highly accurate USO-rate calibration derived from concurrent GPS data, an improved method for extracting high-rate biased range from baseband phase, improved filtering for extracting reduced- rate observables from high-rate biased range, and parallel extraction of three observable types.

SINUSOIDAL SIGNALS↗

Design of a Thomson scattering diagnostic for the SMall Aspect Ratio Tokamak (SMART)

Here, we describe the design of a Thomson scattering (TS) diagnostic to be used on the SMall Aspect Ratio Tokamak (SMART). SMART is a spherical tokamak being commissioned in Spain that aims to explore positive triangularity and negative triangularity plasma scenarios at a low aspect ratio. The SMART TS diagnostic is designed to operate at high spatial resolution, 6 mm scattering length in the low-field side and 9 mm in the high-field side regions, and a wide dynamic range, electron temperature from 1 eV to 1 keV and density from 5 x 10 18 m -3 to 1 x 10 20 m -3 ⁠, to resolve large gradients formed at the plasma edge and in the scrape-off layer (SOL) under different triangularities and low aspect ratios. A 2 J @1064 nm laser will be used that is capable of operating in the burst mode at 1, 2, and 4 kHz to investigate fast phenomena and at 30 Hz to study 1 s (or more) long discharges. The scattered light will be collected over an angular range of 60° – 120° from 28 spatial points in the midplane covering the entire plasma width and the outer midplane SOL. Each scattering signal will be spectrally resolved on five wavelength channels of a polychromator to obtain the electron temperature measurement. We will also present a method to monitor in situ laser alignment in the core during calibrations and plasma operations.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Ultrasound Thermal Field Imaging of Opaque Fluids

We have initiated an experimental program to develop an ultrasound system for non-intrusively imaging the thermal field in opaque fluids under an externally imposed temperature gradient. Many industrial processes involve opaque fluids, such as molten metals, semiconductors, and polymers, often in situations in which thermal gradients are important. For example, one may wish to understand semiconductor crystal growth dynamics in a Bridgman apparatus. Destructive testing of the crystal after the process is completed gives only indirect information about the fluid dynamics of the formation process. Knowledge of the coupled thermal and velocity fields during the growth process is then essential. Most techniques for non-intrusive velocity and temperature measurement in fluids are optical in nature, and hence the fluids studied must be transparent. In some cases (for example, LDV (laser Doppler velocimetry) and PIV (particle imaging velocimetry)) the velocities of small neutrally buoyant seed particles suspended in the fluid, are measured. Without particle seeding one can use the variation of the index of refraction of the fluid with temperature to visualize, through interferometric, Schlieren or shadowgraph techniques, the thermal field. The thermal field in turn gives a picture of the pattern existing in the fluid. If the object of study is opaque, non-optical techniques must be used. In this project we focus on the use of ultrasound, which propagates easily through opaque liquids and solids. To date ultrasound measurements have almost exclusively relied on the detection of sound scattered from density discontinuities inside the opaque material of interest. In most cases it has been used to visualize structural properties, but more recently the ultrasound Doppler velocimeter has become available. As in the optical case, it relies on seed particles that scatter Doppler shifted sound back to the detector. Doppler ultrasound techniques are, however, not useful for studying convective fluid flow in crystal growth, because particle seeding is unacceptable and flow velocities are typically too low to be resolved, and may be even lower in microgravity conditions where buoyancy forces are negligible. We will investigate a different use of ultrasound to probe the flows of opaque fluids non-intrusively and without the use of seed particles: our goal is to ultrasonically visualize the thermal field of opaque fluids with relatively high spatial resolution. The proposed technique relies upon the variation of sound speed with temperature of the fluid. A high frequency ultra-sound pulse passing through a fluid-filled chamber will traverse the chamber in a time determined by the relevant chamber dimension and the temperature of the fluid through which the pulse passes. With high time-resolution instrumentation that compares the excitation signal with the received pulse we can detect the influence of the fluid temperature on the pulse travel time. This is effectively an interferometric system, which in its optical form is an extremely sensitive approach to measuring thermal fields in fluids. Moreover, the temperature dependence of sound velocity in liquid metals is comparable to the temperature dependence of the speed of light required for accurate interferometric thermal images in transparent fluids. With an array of transducers scanned electronically a map of the thermal field over the chamber could be produced. An alternative approach would be to use the ultrasound analog of the shadowgraph technique. In the optical version, collimated light passes through the fluid, where it is focused or defocused locally by temperature field induced variations of the index of refraction. The resulting image reveals the thermal field through the spatial pattern of light intensity variations. By analogy, an ultrasound plane wave traversing an opaque fluid sample would be also locally focused or defocused depending on the speed of sound variations, giving rise to spatial variations in sound intensity that will reveal the thermal field pattern. These approaches could be applied to any situation in which temperature differences are expected to occur, and will rapidly provide information about the flow that simply cannot be obtained by any current intrusive or non-intrusive diagnostic technique. As materials processing in microgravity matures it will become increasingly important to have available simple and versatile diagnostic tools, such as we will develop, for studying the flows of opaque fluids under thermal forcing.

Andereck, C. David↗

Vulnerability of OFDR-based distributed sensors to radiations

Silica-based optical fibers have recently attracted much interest for their use in harsh environments such as the ones encountered in space, military or high energy physics applications. Small size, fast response, light weight and immunity to electromagnetic fields are favorable advantages that often become decisive for fiber sensing to be chosen over other conventional sensing technologies. As an important and representative example, Fukushima's accident highlighted weaknesses in the safety of nuclear power plants. Since, one of the strategic research axis of the nuclear industry is devoted to the development of novel technologies and sensors to enhance and reinforce the safety in nuclear power plants, especially in the case of accidental conditions associated with a strong increase of the constraints applied to the fiber-based system. The objective of this research field is to develop classes of distributed fiber-based sensors using scattering-based techniques, powerful solutions for various measurands measurement. Optical fiber properties, indeed, depend on several external parameters such as temperature, strain and therefore the fiber itself can be used as the sensitive element. Different classes of fiber-based sensing techniques have been recently investigated such as Fiber Bragg Gratings (FBGs) for discrete measurements and Brillouin, Raman and Rayleigh [8,9] scattering based techniques for distributed measurements of various environmental parameters. Whereas Brillouin and Raman sensor resolutions remain in the range of one meter, the advantage of Rayleigh scattering based technique is that it offers very high spatial resolution from 1 cm down to few μm over several hundred meters of fiber length down to few meters respectively. For nuclear industry, integrating fibers-based sensors has to improve the performances (resolution, operating range,...) of security systems in current nuclear power plants (NPPs) and offers new alternative technologies that may overcome the issues identified for next generation of NPPs. Such integration will only be possible if the OFDR based systems are able to resist to the constraints associated with industrial environments, one of the most constraining being the presence of high level of radiations. In this work, we carry out a systematic study to highlight the OFDR interest and sensitivity to probe the optical samples at high irradiation dose levels. The responses of five optical fibers types, from radiation hardened to radiation sensitive ones, are investigated to explore the influence of both the material compositions and the γ-irradiation on the ODFR sensors. Using these samples, we should highlight the influence of the core dopant concentration on the observed radiation-induced changes as well as the difference observed when the cladding is either radiation resistant or radiation sensitive. Our samples were irradiated using a {sup 60}Co source facility reaching total doses varying from 1 MGy up to a maximum of 10 MGy. All the measurements are performed after diverse months from irradiation to study permanents effects induced from these high γ-rays doses. We'll present at the conference all the experimental results acquired and use them to estimate the potential of OFDR-based systems for operation in radiation environments. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Aerosol Airmass Type Mapping Over the Urban Mexico City Region From Space-based Multi-angle Imaging

Using Multi-angle Imaging SpectroRadiometer (MISR) and sub-orbital measurements from the 2006 INTEX-B/MILAGRO field campaign, in this study we explore MISR's ability to map different aerosol air mass types over the Mexico City metropolitan area. The aerosol air mass distinctions are based on shape, size and single scattering albedo retrievals from the MISR Research Aerosol Retrieval algorithm. In this region, the research algorithm identifies dust-dominated aerosol mixtures based on non-spherical particle shape, whereas spherical biomass burning and urban pollution particles are distinguished by particle size. Two distinct aerosol air mass types based on retrieved particle microphysical properties, and four spatially distributed aerosol air masses, are identified in the MISR data on 6 March 2006. The aerosol air mass type identification results are supported by coincident, airborne high-spectral-resolution lidar (HSRL) measurements. Aerosol optical depth (AOD) gradients are also consistent between the MISR and sub-orbital measurements, but particles having single-scattering albedo of approx. 0.7 at 558 nm must be included in the retrieval algorithm to produce good absolute AOD comparisons over pollution-dominated aerosol air masses. The MISR standard V22 AOD product, at 17.6 km resolution, captures the observed AOD gradients qualitatively, but retrievals at this coarse spatial scale and with limited spherical absorbing particle options underestimate AOD and do not retrieve particle properties adequately over this complex urban region. However, we demonstrate how AOD and aerosol type mapping can be accomplished with MISR data over complex urban regions, provided the retrieval is performed at sufficiently high spatial resolution, and with a rich enough set of aerosol components and mixtures.

aerosol optical depth↗

A Next-Generation Hard X-Ray Nanoprobe Beamline for In Situ Studies of Energy Materials and Devices

The Advanced Photon Source is developing a suite of new X-ray beamlines to study materials and devices across many length scales and under real conditions. One of the flagship beamlines of the APS upgrade is the In Situ Nanoprobe (ISN) beamline, which will provide in situ and operando characterization of advanced energy materials and devices under varying temperatures, gas ambients, and applied fields, at previously unavailable spatial resolution and throughput. Examples of materials systems include inorganic and organic photovoltaic systems, advanced battery systems, fuel cell components, nanoelectronic devices, advanced building materials and other scientifically and technologically relevant systems. To characterize these systems at very high spatial resolution and trace sensitivity, the ISN will use both nanofocusing mirrors and diffractive optics to achieve spots sizes as small as 20 nm. Nanofocusing mirrors in Kirkpatrick–Baez geometry will provide several orders of magnitude increase in photon flux at a spatial resolution of 50 nm. Diffractive optics such as zone plates and/or multilayer Laue lenses will provide a highest spatial resolution of 20 nm. Coherent diffraction methods will be used to study even small specimen features with sub-10 nm relevant length scale. A high-throughput data acquisition system will be employed to significantly increase operations efficiency and usability of the instrument. The ISN will provide full spectroscopy capabilities to study the chemical state of most materials in the periodic table, and enable X-ray fluorescence tomography. In situ electrical characterization will enable operando studies of energy and electronic devices such as photovoltaic systems and batteries. We also describe the optical concept for the ISN beamline, the technical design, and the approach for enabling a broad variety of in situ studies. Furthermore, we discuss the application of hard X-ray microscopy to study defects in multi-crystalline solar cells, one of the lines of inquiries for which the ISN is being developed.

42 ENGINEERING↗

Flood hazard model calibration using multiresolution model output

Riverine floods pose a considerable risk to many communities. Improving flood hazard projections has the potential to inform the design and implementation of flood risk management strategies. Current flood hazard projections are uncertain, especially due to uncertain model parameters. Calibration methods use observations to quantify model parameter uncertainty. With limited computational resources, researchers typically calibrate models using either relatively few expensive model runs at high spatial resolutions or many cheaper runs at lower spatial resolutions. This leads to an open question: is it possible to effectively combine information from the high and low resolution model runs? We propose a Bayesian emulation–calibration approach that assimilates model outputs and observations at multiple resolutions. As a case study for a riverine community in Pennsylvania, we demonstrate our approach using the LISFLOOD-FP flood hazard model. Here, the multiresolution approach results in improved parameter inference over the single resolution approach in multiple scenarios. Results vary based on the parameter values and the number of available models runs. Our method is general and can be used to calibrate other high dimensional computer models to improve projections.

multiresolution↗