Search NASA⌕ Search

SEARCH · Search NASA

Results for “image coding”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 721 records · Page 40

Applications of LIF to Document Natural Variability of Chlorophyll Content and Cu Uptake in Moss

Chlorophyll has long been used as a natural indicator of plant health and photosynthetic efficiency. Laser-induced fluorescence (LIF) is an emerging technique for understanding broad spectrum organic processes and has more recently been used to monitor chlorophyll response in plants. Previous work has focused on developing a LIF technique for imaging moss mats to identify metal contamination with the current focus shifting toward application to moss fronds and aiding sample collection for chemical analysis. Two laser systems (CoCoBi a Nd:YGa pulsed laser system and Chl-SL with two blue continuous semiconductor diodes) were used to collect images of moss fronds exposed to increasing levels of Cu (1, 10, and 100 nmol/cm 2 ) using a CMOS camera. The best methods for the preprocessing of images were conducted before the analysis of fluorescence signatures were compared to a control. The Chl-SL system performed better than the CoCoBi, with dynamic time warping (DTW) proving the most effective for image analysis. Manual thresholding to remove lower decimal code values improved the data distributions and proved whether using one or two fronds in an image was more advantageous. A higher DTW difference from the control correlated to lower chlorophyll a/b ratios and a higher metal content, indicating that LIF, with the aid of image processing, can be an effective technique for identifying Cu contamination shortly after an event.

59 BASIC BIOLOGICAL SCIENCES↗

A Generative Model for Realistic Galaxy Cluster X-Ray Morphologies

Abstract The X-ray morphologies of clusters of galaxies display significant variations, reflecting their dynamical histories and the nonlinear dependence of X-ray emissivity on the density of the intracluster gas. Qualitative and quantitative assessments of X-ray morphology have long been considered a proxy for determining whether clusters are dynamically active or “relaxed.” Conversely, the use of circularly or elliptically symmetric models for cluster emission can be complicated by the variety of complex features realized in nature, spanning scales from megaparsecs down to the resolution limit of current X-ray observatories. In this work, we use mock X-ray images from simulated clusters from The Three Hundred project to define a basis set of cluster image features. We take advantage of the clusters’ approximate self-similarity to minimize the differences between images before encoding the remaining diversity through a distribution of high-order polynomial coefficients. Principal component analysis then provides an orthogonal basis for this distribution, corresponding to natural perturbations from an average model. This representation allows novel, realistically complex X-ray cluster images to be easily generated, and we provide code to do so. The approach provides a simple way to generate training data for cluster image analysis algorithms and could be straightforwardly adapted to generate clusters displaying specific types of features or selected by physical characteristics available in the original simulations.

79 ASTRONOMY AND ASTROPHYSICS↗

Neural-Based Compression Scheme for Solar Image Data

Studying the solar system and especially the Sun relies on the data gathered daily from space missions. These missions are data-intensive and compressing this data to make them efficiently transferable to the ground station is a twofold decision to make. Stronger compression methods, by distorting the data, can increase data throughput at the cost of accuracy which could affect scientific analysis of the data. On the other hand, preserving subtle details in the compressed data requires a high amount of data to be transferred, reducing the desired gains from compression. In this work, we propose a neural network-based lossy compression method to be used in NASA’s data-intensive imagery missions. We chose NASA’s Solar Dynamics Observatory (SDO) mission which transmits 1.4 terabytes of data each day as a proof of concept for the proposed algorithm. In this work, we propose an adversarially trained neural network, equipped with local and non-local attention modules to capture both the local and global structure of the image resulting in a better trade-off in rate-distortion (RD) compared to conventional hand-engineered codecs. The RD variational autoencoder used in this work is jointly trained with a channel-dependent entropy model as a shared prior between the analysis and synthesis transforms to make the entropy coding of the latent code more effective. We also studied how optimizing perceptual losses could help our neural compressor to preserve high-frequency details of the data in the reconstructed compressed image. Our neural image compression algorithm outperforms currently-in-use and state-of-the-art codecs such as JPEG and JPEG-2000 in terms of the RD performance when compressing extreme-ultraviolet (EUV) data. As a proof of concept for use of this algorithm in SDO data analysis, we have performed coronal hole (CH) detection using our compressed images, and generated consistent segmentations, even at a compression rate of ∼ 0.1 bits per pixel (compared to 8 bits per pixel on the original data) using EUV data from SDO.

Image coding↗

Practical Method of Adaptive Radiotherapy for Prostate Cancer Using Real-Time Electromagnetic Tracking

Purpose: We have created an automated process using real-time tracking data to evaluate the adequacy of planning target volume (PTV) margins in prostate cancer, allowing a process of adaptive radiotherapy with minimal physician workload. We present an analysis of PTV adequacy and a proposed adaptive process. Methods and Materials: Tracking data were analyzed for 15 patients who underwent step-and-shoot multi-leaf collimation (SMLC) intensity-modulated radiation therapy (IMRT) with uniform 5-mm PTV margins for prostate cancer using the Calypso Registered-Sign Localization System. Additional plans were generated with 0- and 3-mm margins. A custom software application using the planned dose distribution and structure location from computed tomography (CT) simulation was developed to evaluate the dosimetric impact to the target due to motion. The dose delivered to the prostate was calculated for the initial three, five, and 10 fractions, and for the entire treatment. Treatment was accepted as adequate if the minimum delivered prostate dose (D{sub min}) was at least 98% of the planned D{sub min}. Results: For 0-, 3-, and 5-mm PTV margins, adequate treatment was obtained in 3 of 15, 12 of 15, and 15 of 15 patients, and the delivered D{sub min} ranged from 78% to 99%, 96% to 100%, and 99% to 100% of the planned D{sub min}. Changes in D{sub min} did not correlate with magnitude of prostate motion. Treatment adequacy during the first 10 fractions predicted sufficient dose delivery for the entire treatment for all patients and margins. Conclusions: Our adaptive process successfully used real-time tracking data to predict the need for PTV modifications, without the added burden of physician contouring and image analysis. Our methods are applicable to other uses of real-time tracking, including hypofractionated treatment.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Advanced ballistic range technology

Optical images, such as experimental interferograms, schlieren, and shadowgraphs, are routinely used to identify and locate features in experimental flow fields and for validating computational fluid dynamics (CFD) codes. Interferograms can also be used for comparing experimental and computed integrated densities. By constructing these optical images from flow-field simulations, one-to-one comparisons of computation and experiment are possible. During the period from February 1, 1992, to November 30, 1992, work has continued on the development of CISS (Constructed Interferograms, Schlieren, and Shadowgraphs), a code that constructs images from ideal- and real-gas flow-field simulations. In addition, research connected with the automated film-reading system and the proposed reactivation of the radiation facility has continued.

Yates, Leslie A.↗

Aerial Scene Recognition using Efficient Sparse Representation

Advanced scene recognition systems for processing large volumes of high-resolution aerial image data are in great demand today. However, automated scene recognition remains a challenging problem. Efficient encoding and representation of spatial and structural patterns in the imagery are key in developing automated scene recognition algorithms. We describe an image representation approach that uses simple and computationally efficient sparse code computation to generate accurate features capable of producing excellent classification performance using linear SVM kernels. Our method exploits unlabeled low-level image feature measurements to learn a set of basis vectors. We project the low-level features onto the basis vectors and use simple soft threshold activation function to derive the sparse features. The proposed technique generates sparse features at a significantly lower computational cost than other methods~\cite{Yang10, newsam11}, yet it produces comparable or better classification accuracy. We apply our technique to high-resolution aerial image datasets to quantify the aerial scene classification performance. We demonstrate that the dense feature extraction and representation methods are highly effective for automatic large-facility detection on wide area high-resolution aerial imagery.

Computer Vision↗

Infrared Astronomical Satellite (IRAS) analysis, appendix C. APART: A first-order deterministic stray radiation analysis program

The APART code (Arizona's Analysis of Radiation Transfer) is a deterministic stray radiation analysis program capable of yielding quantitative descriptions of systems along with insight into the scattering mechanism present. It uses geometrical optics to image primarily rotationally symmetrical systems. The APART code provides a sectional power map of the internal surfaces of a system and identifies critical objects seen from the image. Vane structures are modeled by configuration factors. Once the geometrical configuration factor between the internal objects has been calculated and stored, nonstructural changes to the system can be analyzed without re-running the complete program.

Source record↗

Automated bubble analysis of high-speed subcooled flow boiling images using U-net transfer learning and global optical flow

Capturing and analyzing the bubble dynamics is crucial to improving the understanding of boiling heat transfer mechanisms and predicting boiling heat transfer coefficient and boiling crisis. High speed video (HSV) imaging has been used for decades towards this end. Still, there is no universal approach to quantitatively analyze bubble dynamics from HSV images. In this study, we propose a data-driven post-processing approach to segment, track, and identify wall-attached vapor bubbles from HSV images of the boiling process in subcooled flow conditions. Firstly, we employ a transfer learning framework with a U-Net-based convolution neural network (CNN) architecture to detect and segment bubbles in HSV images of diverse contrast and surface texture using very little data (e.g., 10 images) for training. Then, we evaluate the trained CNN model with 100 ground-truth images, and the validation results show that the model accuracy and precision in detecting the optical footprint of bubbles are higher than 90%. Finally, we suggest a criterion to identify a condensing bubble based on the divergence of the bubble displacement, which is calculated from sequential segmented bubble images using a global optical flow code. Using this combination of machine learning and optical flow, we can identify nucleation sites and track the growth of bubbles nucleating at each site to quantify nucleation site density, nucleation frequency, and other fundamental boiling parameters. The proposed system is validated using results obtained on a special heater, which enables both infrared (IR) thermometry and HSV imaging on a metallic surface. We compare the fundamental boiling parameters obtained by the two different diagnostics. The results show good agreement. In conclusion, the difference between the measurements of nucleation site density, averaged nucleation frequency, and averaged growth time performed with the two techniques is always within ± 20% and mostly ± 10% of the values measured with IR thermometry.

42 ENGINEERING↗

Simplifying EPID dosimetry for IMRT treatment verification

Purpose: Electronic portal imaging devices (EPIDs) are increasingly used for IMRT dose verification, both pretreatment and in vivo. In this study, an earlier developed backprojection model has been modified to avoid the need for patient-specific transmission measurements and, consequently, leads to a faster procedure. Methods: Currently, the transmission, an essential ingredient of the backprojection model, is estimated from the ratio of EPID measurements with and without a phantom/patient in the beam. Thus, an additional irradiation to obtain ''open images'' under the same conditions as the actual phantom/patient irradiation is required. However, by calculating the transmission of the phantom/patient in the direction of the beam instead of using open images, this extra measurement can be avoided. This was achieved by using a model that includes the effect of beam hardening and off-axis dependence of the EPID response on photon beam spectral changes. The parameters in the model were empirically obtained by performing EPID measurements using polystyrene slab phantoms of different thickness in 6, 10, and 18 MV photon beams. A theoretical analysis to verify the sensitivity of the model with patient thickness changes was performed. The new model was finally applied for the analysis of EPID dose verification measurements of step-and-shoot IMRT treatments of head and neck, lung, breast, cervix, prostate, and rectum patients. All measurements were carried out using Elekta SL20i linear accelerators equipped with a hydrogenated amorphous silicon EPID, and the IMRT plans were made using PINNACLE software (Philips Medical Systems). Results: The results showed generally good agreement with the dose determined using the old model applying the measured transmission. The average differences between EPID-based in vivo dose at the isocenter determined using either the new model for transmission and its measured value were 2.6{+-}3.1%, 0.2{+-}3.1%, and 2.2{+-}3.9% for 47 patients treated with 6, 10, and 18 MV IMRT beams, respectively. For the same group of patients, the differences in mean {gamma} analysis (3% maximum dose, 3 mm) were 0.16{+-}0.26%, 0.21{+-}0.24%, and 0.02{+-}0.12%, respectively. For a subgroup of 11 patients, pretreatment verification was also performed, showing similar dose differences at the isocenter: -1.9{+-}0.9%, -1.4{+-}1.2%, and -0.4{+-}2.4%, with somewhat lower mean {gamma} difference values: 0.01{+-}0.09%, 0.01{+-}0.07%, and -0.09{+-}0.10%, respectively. Clinical implementation of the new model would save 450 h/yr spent in measurement of open images. Conclusions: It can be concluded that calculating instead of measuring the transmission leads to differences in the isocenter dose generally smaller than 2% (2.6% for 6 MV photon beams for in vivo dose) and yielded only slightly higher {gamma}-evaluation parameter values in planes through the isocenter. Hence, the new model is suitable for clinical implementation and measurement of open images can be omitted.

61 RADIATION PROTECTION AND DOSIMETRY↗

Atmospheric Correction of Satellite Imagery Using Modtran 3.5 Code

When performing satellite remote sensing of the earth in the solar spectrum, atmospheric scattering and absorption effects provide the sensors corrupted information about the target's radiance characteristics. We are faced with the problem of reconstructing the signal that was reflected from the target, from the data sensed by the remote sensing instrument. This article presents a method for simulating radiance characteristic curves of satellite images using a MODTRAN 3.5 band model (BM) code to solve the radiative transfer equation (RTE), and proposes a method for the implementation of an adaptive system for automated atmospheric corrections. The simulation procedure is carried out as follows: (1) for each satellite digital image a radiance characteristic curve is obtained by performing a digital number (DN) to radiance conversion, (2) using MODTRAN 3.5 a simulation of the images characteristic curves is generated, (3) the output of the code is processed to generate radiance characteristic curves for the simulated cases. The simulation algorithm was used to simulate Landsat Thematic Mapper (TM) images for two types of locations: the ocean surface, and a forest surface. The simulation procedure was validated by computing the error between the empirical and simulated radiance curves. While results in the visible region of the spectrum where not very accurate, those for the infrared region of the spectrum were encouraging. This information can be used for correction of the atmospheric effects. For the simulation over ocean, the lowest error produced in this region was of the order of 105 and up to 14 times smaller than errors in the visible region. For the same spectral region on the forest case, the lowest error produced was of the order of 10-4, and up to 41 times smaller than errors in the visible region,

Gonzales, Fabian O.↗

A Standardized Analysis Process Using Digital Image Correlation to Calculate In Situ Cladding Strain from Modified Burst Tests for Fuel Performance Code Validation

Historical data collection on nuclear fuel cladding materials has focused on generating a statistically significant amount of data to assess the material and its failure behavior. Furthermore, data generated to support material model and failure criteria development were previously posttest evaluations, so a large number of tests was required to gain new understanding. A way to expedite this process is to develop techniques capable of generating large, high-fidelity data sets from a single test with lower uncertainty or quantified uncertainty. One such example of this approach is Oak Ridge National Laboratory’s use of modified burst tests (MBTs) to analyze the mechanical behavior and failure conditions of cladding during a simulated reactivity-initiated accident (RIA). Each test incorporates digital image correlation (DIC) analysis techniques that are used to assess the accumulated strain in situ, as well as eventual cladding failure. This work has been fruitful in defining strain-to-failure conditions for materials like silicon carbide (SiC) fiber–reinforced/SiC matrix composite tubes (SiC/SiC), iron-chromium-aluminum (FeCrAl) alloy tubes, and chromium-coated Zircaloy-4 tubes. However, there are numerous DIC software available, including open-source and proprietary software. The different DIC software use various algorithms to process images and calculate displacement values. Using these different software and algorithms can lead to varying results, and perhaps larger-than-expected uncertainties. In the present study, previously published MBT data encompassing a variety of test conditions were reanalyzed with two different DIC software to assess the variance in the calculated strain results. The data consisted of SiC/SiC, FeCrAl, and chromium-coated Zircaloy-4 tubes. Plots of the calculated strains during the transient revealed good agreement between the two DIC software. The average root-mean-square errors between the two software was 0.20% strain, which is slightly larger than a previously reported error value for these tests. In conclusion, this variance in results is low enough that this analysis method can be used for code validation.

Reactivity-initiated accident↗

SU-F-J-188: Clinical Implementation of in Room Mobile CT for Image Guided Proton Therapy

Purpose: To implement soft-tissue image-guided proton therapy using inroom mobile CT. Methods: Anthropomorphic phantom was first used to determine the setup accuracy using in- room mobile CT. Laser and bbs were used for the initial setup (marked isocenter). CT data was then acquired with in-room mobile CT (daily CT). The shift between the marked isocenter and the planned isocenter (final isocenter) was determined from the daily CT using in-house Computer Assisted Targeting (CAT) software. Orthogonal DRRs of the day was also generated from the daily CT. The phantom was then transferred on the treatment couch top to the treatment machine using a transportation system, and again aligned to the marked isocenter. Couch shifts were made to align the phantom to the final isocenter using the shifts as determined using the CAT software, and verified using orthogonal X-ray images with the daily DRRs. Results: Phantom data suggests that following the setup procedure as described above, targeting accuracy could be within 1 mm. Patient data are being acquired and analyzed. Conclusion: In-room mobile CT is capable of providing soft-tissue image-guided proton therapy.

60 APPLIED LIFE SCIENCES↗

System and technique for retrieving depth information about a surface by projecting a composite image of modulated light patterns

A technique, associated system and program code, for retrieving depth information about at least one surface of an object. Core features include: projecting a composite image comprising a plurality of modulated structured light patterns, at the object; capturing an image reflected from the surface; and recovering pattern information from the reflected image, for each of the modulated structured light patterns. Pattern information is preferably recovered for each modulated structured light pattern used to create the composite, by performing a demodulation of the reflected image. Reconstruction of the surface can be accomplished by using depth information from the recovered patterns to produce a depth map/mapping thereof. Each signal waveform used for the modulation of a respective structured light pattern, is distinct from each of the other signal waveforms used for the modulation of other structured light patterns of a composite image; these signal waveforms may be selected from suitable types in any combination of distinct signal waveforms, provided the waveforms used are uncorrelated with respect to each other. The depth map/mapping to be utilized in a host of applications, for example: displaying a 3-D view of the object; virtual reality user-interaction interface with a computerized device; face--or other animal feature or inanimate object--recognition and comparison techniques for security or identification purposes; and 3-D video teleconferencing/telecollaboration.

Hassebrook, Laurence G.↗

SU-E-T-117: Dose to Organs Outside of CT Scan Range- Monte Carlo and Hybrid Phantom Approach

Purpose: Epidemiological study of second cancer risk for cancer survivors often requires the dose to normal tissues located outside the anatomy covered by radiological imaging, which is usually limited to tumor and organs at risk. We have investigated the feasibility of using whole body computational human phantoms for estimating out-of-field organ doses for patients treated by Intensity Modulated Radiation Therapy (IMRT). Methods: Identical 7-field IMRT prostate plans were performed using X-ray Voxel Monte Carlo (XVMC), a radiotherapy-specific Monte Carlo transport code, on the computed tomography (CT) images of the torso of an adult male patient (175 cm height, 66 kg weight) and an adult male hybrid computational phantom with the equivalent body size. Dose to the liver, right lung, and left lung were calculated and compared. Results: Considerable differences are seen between the doses calculated by XVMC for the patient CT and the hybrid phantom. One major contributing factor is the treatment method, deep inspiration breath hold (DIBH), used for this patient. This leads to significant differences in the organ position relative to the treatment isocenter. The transverse distances from the treatment isocenter to the inferior border of the liver, left lung, and right lung are 19.5cm, 29.5cm, and 30.0cm, respectively for the patient CT, compared with 24.3cm, 36.6cm, and 39.1cm, respectively, for the hybrid phantom. When corrected for the distance, the mean doses calculated using the hybrid phantom are within 28% of those calculated using the patient CT. Conclusion: This study showed that mean dose to the organs located in the missing CT coverage can be reconstructed by using whole body computational human phantoms within reasonable dosimetric uncertainty, however appropriate corrections may be necessary if the patient is treated with a technique that will significantly deform the size or location of the organs relative to the hybrid phantom.

60 APPLIED LIFE SCIENCES↗

TU-AB-204-01: Device Approval Process

The responsibilities of the Food and Drug Administration (FDA) have increased since the inception of the Food and Drugs Act in 1906. Medical devices first came under comprehensive regulation with the passage of the 1938 Food, Drug, and Cosmetic Act. In 1971 FDA also took on the responsibility for consumer protection against unnecessary exposure to radiation-emitting devices for home and occupational use. However it was not until 1976, under the Medical Device Regulation Act, that the FDA was responsible for the safety and effectiveness of medical devices. This session will be presented by the Division of Radiological Health (DRH) and the Division of Imaging, Diagnostics, and Software Reliability (DIDSR) from the Center for Devices and Radiological Health (CDRH) at the FDA. The symposium will discuss on how we protect and promote public health with a focus on medical physics applications organized into four areas: pre-market device review, post-market surveillance, device compliance, current regulatory research efforts and partnerships with other organizations. The pre-market session will summarize the pathways FDA uses to regulate the investigational use and commercialization of diagnostic imaging and radiation therapy medical devices in the US, highlighting resources available to assist investigators and manufacturers. The post-market session will explain the post-market surveillance and compliance activities FDA performs to monitor the safety and effectiveness of devices on the market. The third session will describe research efforts that support the regulatory mission of the Agency. An overview of our regulatory research portfolio to advance our understanding of medical physics and imaging technologies and approaches to their evaluation will be discussed. Lastly, mechanisms that FDA uses to seek public input and promote collaborations with professional, government, and international organizations, such as AAPM, International Electrotechnical Commission (IEC), Image Gently, and the Quantitative Imaging Biomarkers Alliance (QIBA) among others, to fulfill FDA’s mission will be discussed. Learning Objectives: Understand FDA’s pre-market and post-market review processes for medical devices Understand FDA’s current regulatory research activities in the areas of medical physics and imaging products Understand how being involved with AAPM and other organizations can also help to promote innovative, safe and effective medical devices J. Delfino, nothing to disclose.

60 APPLIED LIFE SCIENCES↗

TU-AB-204-03: Research Activities in Medical Physics

The responsibilities of the Food and Drug Administration (FDA) have increased since the inception of the Food and Drugs Act in 1906. Medical devices first came under comprehensive regulation with the passage of the 1938 Food, Drug, and Cosmetic Act. In 1971 FDA also took on the responsibility for consumer protection against unnecessary exposure to radiation-emitting devices for home and occupational use. However it was not until 1976, under the Medical Device Regulation Act, that the FDA was responsible for the safety and effectiveness of medical devices. This session will be presented by the Division of Radiological Health (DRH) and the Division of Imaging, Diagnostics, and Software Reliability (DIDSR) from the Center for Devices and Radiological Health (CDRH) at the FDA. The symposium will discuss on how we protect and promote public health with a focus on medical physics applications organized into four areas: pre-market device review, post-market surveillance, device compliance, current regulatory research efforts and partnerships with other organizations. The pre-market session will summarize the pathways FDA uses to regulate the investigational use and commercialization of diagnostic imaging and radiation therapy medical devices in the US, highlighting resources available to assist investigators and manufacturers. The post-market session will explain the post-market surveillance and compliance activities FDA performs to monitor the safety and effectiveness of devices on the market. The third session will describe research efforts that support the regulatory mission of the Agency. An overview of our regulatory research portfolio to advance our understanding of medical physics and imaging technologies and approaches to their evaluation will be discussed. Lastly, mechanisms that FDA uses to seek public input and promote collaborations with professional, government, and international organizations, such as AAPM, International Electrotechnical Commission (IEC), Image Gently, and the Quantitative Imaging Biomarkers Alliance (QIBA) among others, to fulfill FDA’s mission will be discussed. Learning Objectives: Understand FDA’s pre-market and post-market review processes for medical devices Understand FDA’s current regulatory research activities in the areas of medical physics and imaging products Understand how being involved with AAPM and other organizations can also help to promote innovative, safe and effective medical devices J. Delfino, nothing to disclose.

60 APPLIED LIFE SCIENCES↗

TU-AB-204-04: Partnerships

The responsibilities of the Food and Drug Administration (FDA) have increased since the inception of the Food and Drugs Act in 1906. Medical devices first came under comprehensive regulation with the passage of the 1938 Food, Drug, and Cosmetic Act. In 1971 FDA also took on the responsibility for consumer protection against unnecessary exposure to radiation-emitting devices for home and occupational use. However it was not until 1976, under the Medical Device Regulation Act, that the FDA was responsible for the safety and effectiveness of medical devices. This session will be presented by the Division of Radiological Health (DRH) and the Division of Imaging, Diagnostics, and Software Reliability (DIDSR) from the Center for Devices and Radiological Health (CDRH) at the FDA. The symposium will discuss on how we protect and promote public health with a focus on medical physics applications organized into four areas: pre-market device review, post-market surveillance, device compliance, current regulatory research efforts and partnerships with other organizations. The pre-market session will summarize the pathways FDA uses to regulate the investigational use and commercialization of diagnostic imaging and radiation therapy medical devices in the US, highlighting resources available to assist investigators and manufacturers. The post-market session will explain the post-market surveillance and compliance activities FDA performs to monitor the safety and effectiveness of devices on the market. The third session will describe research efforts that support the regulatory mission of the Agency. An overview of our regulatory research portfolio to advance our understanding of medical physics and imaging technologies and approaches to their evaluation will be discussed. Lastly, mechanisms that FDA uses to seek public input and promote collaborations with professional, government, and international organizations, such as AAPM, International Electrotechnical Commission (IEC), Image Gently, and the Quantitative Imaging Biomarkers Alliance (QIBA) among others, to fulfill FDA’s mission will be discussed. Learning Objectives: Understand FDA’s pre-market and post-market review processes for medical devices Understand FDA’s current regulatory research activities in the areas of medical physics and imaging products Understand how being involved with AAPM and other organizations can also help to promote innovative, safe and effective medical devices J. Delfino, nothing to disclose.

60 APPLIED LIFE SCIENCES↗