Search NASA⌕ Search

SEARCH · Search NASA

Results for “interconnected systems”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 721 records · Page 40

Autonomous Reactivity Control (ARC) — Principles, geometry and design process

The Autonomous Reactivity Control (ARC) system was developed to ensure inherent safety performance of Generation-IV reactors while having a minimal impact on reactor performance and economic viability. Here we present in detail the principles of how the ARC system operates, what materials should be used, what components make up the system and how they are interconnected. The relevant equations regarding how to design the system for a certain response are developed and defined, and the most important aspects determining the speed of actuation of the systems are analyzed. Thus, this study serves as the general reference material for all of the fundamental principles behind the ARC idea. Finally, we present a step-by-step guide to how a fast reactor fuel subassembly with an ARC system installed would be manufactured, using a full 3D-CAD model. For an ARC installation in a 1000 MWth sodium-cooled oxide-fueled fast reactor core, the system constitutes a relatively minor adjustment to a typical fuel assembly, increasing its total axial extent by ~5–10% and the total primary coolant pressure drop by ~1%. In conclusion, the main finding of this study is that it is possible to design, manufacture (using existing methods) and implement ARC systems in the fuel assemblies of fast reactor cores to provide inherent safety in all anticipated unprotected transients with only a modest increase in the length of the assembly and the pressure drop across the core.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Renewable Source Controls for Grid Stability

The goal of this study was to evaluate the small signal and transient stability of the Western Electricity Coordinating Council (WECC) under high penetrations of renewable energy, and to identify control technologies that would improve the system performance. The WECC is the regional entity responsible for coordinating and promoting bulk electric system reliability in the Western Interconnection. Transient stability is the ability of the power system to maintain synchronism after a large disturbance while small signal stability is the ability of the power system to maintain synchronism after a small disturbance. Transient stability analysis usually focuses on the relative rotor angle between synchronous machines compared to some stability margin. For this study we employed generator speed relative to system speed as a metric for assessing transient stability. In addition, we evaluated the system transient response using the system frequency nadir, which provides an assessment of the adequacy of the primary frequency control reserves. Small signal stability analysis typically identifies the eigenvalues or modes of the system in response to a disturbance. For this study we developed mode shape maps for the different scenarios. Prony analysis was applied to generator speed after a 1.4 GW, 0.5 second, brake insertion at various locations. Six different WECC base cases were analyzed, including the 2022 light spring case which meets the renewable portfolio standards. Because of the difficulty in identifying the cause and effect relationship in large power system models with different scenarios, several simulations were run on a 7-bus, 5-generator system to isolate the effects of different configurations. Based on the results of the study, for a large power system like the WECC, incorporating frequency droop into wind/solar systems provides a larger benefit to system transient response than replacing the lost inertia with synthetic inertia. From a small signal stability perspective, the increase in renewable penetration results in subtle changes to the system modes. In general, mode frequencies increase slightly, and mode shapes remain similar. The system frequency nadir for the 2022 light spring case was slightly lower than the other cases, largely because of the reduced system inertia. However, the nadir is still well above the minimum load shedding frequency of 59.5 Hz. Finally, several discrepancies were identified between actual and reported wind penetration, and additional work on wind/solar modeling is required to increase the fidelity of the WECC models.

power system stability↗

Interfacing a high performance disk array file server to a Gigabit LAN

Our previous prototype, RAID-1, identified several bottlenecks in typical file server architectures. The most important bottleneck was the lack of a high-bandwidth path between disk, memory, and the network. Workstation servers, such as the Sun-4/280, have very slow access to peripherals on busses far from the CPU. For the RAID-2 system, we addressed this problem by designing a crossbar interconnect, Xbus board, that provides a 40MB/s path between disk, memory, and the network interfaces. However, this interconnect does not provide the system CPU with low latency access to control the various interfaces. To provide a high data rate to clients on the network, we were forced to carefully and efficiently design the network software. A block diagram of the system hardware architecture is given. In the following subsections, we describe pieces of the RAID-2 file server hardware that had a significant impact on the design of the network interface.

Seshan, Srinivasan↗

Robust control of a family of uncertain nonminimum‐phase systems via continuous‐time and sampled‐data output feedback

Summary The problem of global robust stabilization is studied by both continuous‐time and sampled‐data output feedback for a family of nonminimum‐phase nonlinear systems with uncertainty. The uncertain nonlinear system considered in this paper has an interconnect structure consisting of a driving system and a possibly unstable zero dynamics with uncertainty, ie, the uncertain driven system. Under a linear growth condition on the uncertain zero dynamics and a Lipschitz condition on the driving system, we show that it is possible to globally robustly stabilize the family of uncertain nonminimum‐phase systems by a single continuous‐time or a sampled‐data output feedback controller. The sampled‐data output feedback controller is designed by using the emulated versions of a continuous‐time observer and a state feedback controller, ie, by holding the input/output signals constant over each sampling interval. The design of either continuous‐time or sampled‐data output compensator uses only the information of the nominal system of the uncertain controlled plant. In the case of sampled‐data control, global robust stability of the hybrid closed‐loop system with uncertainty is established by means of a feedback domination method together with the robustness of the nominal closed‐loop system if the sampling time is small enough.

Lin, Wei↗

Waiting in Queue: A Historical Evaluation of Interconnection Policy

Both states and Independent System Operators (ISO)/Regional Transmission Organizations (RTO) have struggled with long wait times in interconnection queues. As a result, numerous reforms have been proposed to expedite the connection of new resources to the grid. This paper conducts a quantitative analysis of two of these policies: one providing detail hosting capacity information in Massachusetts, the other experimenting with cost allocation in New York. We find that both policies led to a statistically significant decrease in the times projects spend pending in interconnection queues, with New York seeing a small drop in days pending, and Massachusetts seeing a much larger one. We also include an analysis of how energy storage is impacts queue time in these states. These results can help inform regulators who are weighing reforms to interconnection policies, with the goal of reducing wait times.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Effects of voltage control in utility interactive dispersed storage and generation systems

When a small generator is connected to the distribution system, the voltage at the point of interconnection is determined largely by the system and not the generator. The effect on the generator, on the load voltage and on the distribution system of a number of different voltage control strategies in the generator is examined. Synchronous generators with three kinds of exciter control are considered, as well as induction generators and dc/ac inverters, with and without capacitor compensation. The effect of varying input power during operation (which may be experienced by generators based on renewable resources) is explored, as well as the effect of connecting and disconnecting the generator at ten percent of its rated power. Operation with a constant slightly lagging factor is shown to have some advantages.

Kirkham, H.↗

Systems Engineering and Assurance Modeling (SEAM): A Web-Based Solution for Integrated Mission Assurance

We present an overview of the Systems Engineering and Assurance Modeling (SEAM) platform, a web-browser-based tool which is designed to help engineers evaluate the radiation vulnerabilities and develop an assurance approach for electronic parts in space systems. The SEAM framework consists of three interconnected modeling tools, a SysML compatible system description tool, a Goal Structuring Notation (GSN) visual argument tool, and Bayesian Net and Fault Tree extraction and export tools. The SysML and GSN sections also have a coverage check application that ensures that every radiation fault identified on the SysML side is also addressed in the assurance case in GSN. The SEAM platform works on space systems of any degree of radiation hardness but is especially helpful for assessing radiation performance in systems with commercial-off-the-shelf (COTS) electronic components.

SEAM↗

Communications and control for electric power systems

The first section of the report describes the AbNET system, a hardware and software communications system designed for distribution automation (it can also find application in substation monitoring and control). The topology of the power system fixes the topology of the communications network, which can therefore be expected to include a larger number of branch points, tap points, and interconnections. These features make this communications network unlike any other. The network operating software has to solve the problem of communicating to all the nodes of a very complex network in as reliable a way as possible even if the network is damaged, and it has to do so with minimum transmission delays and at minimum cost. The design of the operating protocols is described within the framework of the seven-layer Open System Interconnection hierarchy of the International Standards Organization. Section 2 of the report describes the development and testing of a high voltage sensor based on an electro-optic polymer. The theory of operation is reviewed. Bulk fabrication of the polymer is discussed, as well as results of testing of the electro-optic coefficient of the material. Fabrication of a complete prototype sensor suitable for use in the range 1-20 kV is described. The electro-optic polymer is shown to be an important material for fiber optic sensing applications. Appendix A is theoretical support for this work. The third section of the report presents the application of an artificial neural network, Kohonen's self-organizing feature map, for the classification of power system states. This classifier maps vectors of an N-dimensional space to a 2-dimensional neural net in a nonlinear way preserving the topological order of the input vectors. These mappings are studied using a nonlinear power system model.

Kirkham, H.↗

Collaborative operational fault tolerant control for stochastic distribution control system

Based on a class of industry processes, a distributed fault diagnosis and a collaborative operational fault tolerant control algorithms are presented for an irreversible interconnected stochastic distribution control system with boundary conditions. Different from the existed collaborative fault tolerant controllers, the controller does not need to change after fault occurs, the system tracking performance can be maintained by adjusting the setpoint of the whole system. Simulations are also included to show the effectiveness of the proposed algorithm and encouraging results have been obtained.

Stochastic distribution control, Fault diagnosis, ↗

Frequency Control and Dynamics (Part 1) [Slides]

This presentation provides an introductory overview of system dynamics and frequency control in electric power systems, with a focus on concepts relevant to small and interconnected grids such as those in Malawi. It explains foundational principles of AC system frequency, the relationship between generation-demand balance and frequency deviations, and the operational limits of generators and end-use equipment. The deck discusses frequency stability within broader system stability classifications and illustrates how inertia and turbine-governor dynamics shape system response to disturbances. It then outlines the tiered approach to frequency control - primary, secondary, and tertiary - detailing the roles, characteristics, timescales, and response mechanisms of each. Special emphasis is placed on hydro and thermal unit behavior, area control error (ACE), automatic generation control (AGC), and the operational implications of interconnecting small systems with larger grids. The material was developed to support Malawi's electricity sector and the establishment of the Southern Africa Battery Energy Storage Center of Excellence (SABESS CoE).

24 POWER TRANSMISSION AND DISTRIBUTION↗

Frequency Control and Dynamics (Part 2) [Slides]

This presentation provides an introductory overview of system dynamics and frequency control in electric power systems, with a focus on concepts relevant to small and interconnected grids such as those in Malawi. It explains foundational principles of AC system frequency, the relationship between generation-demand balance and frequency deviations, and the operational limits of generators and end-use equipment. The deck discusses frequency stability within broader system stability classifications and illustrates how inertia and turbine-governor dynamics shape system response to disturbances. It then outlines the tiered approach to frequency control - primary, secondary, and tertiary - detailing the roles, characteristics, timescales, and response mechanisms of each. Special emphasis is placed on hydro and thermal unit behavior, area control error (ACE), automatic generation control (AGC), and the operational implications of interconnecting small systems with larger grids. The material was developed to support Malawi's electricity sector and the establishment of the Southern Africa Battery Energy Storage Center of Excellence (SABESS CoE).

24 POWER TRANSMISSION AND DISTRIBUTION↗

A Cyber-Resilience Risk Management Architecture for Distributed Wind

Distributed wind is an electric energy resource segment with strong potential to be deployed in many applications, but special consideration of resilience and cybersecurity is needed to address the unique conditions associated with distributed wind. Distributed wind is a strong candidate to help meet renewable energy and carbon-free energy goals. However, care must be taken as more systems are installed to ensure that the systems are reliable, resilient, and secure. The physical and communications requirements for distributed wind mean that there are unique cybersecurity considerations, but there is little to no existing guidance on best practices for cybersecurity risk management for distributed wind systems specifically. This research develops an architecture for the consideration of cyber risks associated with distributed wind systems. The architecture takes into account the configurations, challenges, and standards for distributed wind to create a risk-focused perspective that considers of threats, vulnerabilities, and consequences, with special emphasis on what sets distributed wind systems apart from other distributed energy resources (DER). We discuss common distributed wind architectures and how they are interconnected to larger power systems. Because cybersecurity cannot exist independently, the cyber-resilience architecture must consider the system holistically. Finally, we discuss the implementation of a risk assessment process that uses the cyber-resilience framework to address challenges specific to distributed wind.

17 WIND ENERGY↗

Machine-learning-aided cognitive reconfiguration for flexible-bandwidth HPC and data center networks [Invited]

This paper proposes a machine-learning (ML)-aided cognitive approach for effective bandwidth reconfiguration in optically interconnected datacenter/high-performance computing (HPC) systems. The proposed approach relies on a Hyper-X-like architecture augmented with flexible-bandwidth photonic interconnections at large scales using a hierarchical intra/inter-POD photonic switching layout. We first formulate the problem of the connectivity graph and routing scheme optimization as a mixed-integer linear programming model. A two-phase heuristic algorithm and a joint optimization approach are devised to solve the problem with low time complexity. Then, we propose an ML-based end-to-end performance estimator design to assist the network control plane with intelligent decision making for bandwidth reconfiguration. Numerical simulations using traffic distribution profiles extracted from HPC applications traces as well as random traffic matrices verify the accuracy performance of the ML design estimator ( < <#comment/> 9 % <#comment/> error) and demonstrate up to 5 × <#comment/> throughput gain from the proposed approach compared with the baseline Hyper-X network using fixed all-to-all intra/inter-portable data center interconnects.

Chen, Xiaoliang (ORCID:0000000278056237)↗

Applications of SPICE for modeling miniaturized biomedical sensor systems

This paper proposes a model for a miniaturized signal conditioning system for biopotential and ion-selective electrode arrays. The system consists of three main components: sensors, interconnections, and signal conditioning chip. The model for this system is based on SPICE. Transmission-line based equivalent circuits are used to represent the sensors, lumped resistance-capacitance circuits describe the interconnections, and a model for the signal conditioning chip is extracted from its layout. A system for measurements of biopotentials and ionic activities can be miniaturized and optimized for cardiovascular applications based on the development of an integrated SPICE system model of its electrochemical, interconnection, and electronic components.

Microelectrodes↗

Cyber Security of the Electric Power Grid

Economic security and quality of life in modern society depend on the reliable supply and delivery of electric power. New cyber security vulnerabilities are emerging that introduce new risks to the Nation’s electric power grid. This presentation will describe issues, trends, and research opportunities for enhancing the cyber security of control systems associated with electric power system operations.

computer security↗

Capabilities for Uncertainty in Predictive Science (LDRD Final Report)

Predictive simulation of systems comprised of numerous interconnected, tightly coupled components promises to help solve many problems of scientific and national interest. However predictive simulation of such systems is extremely challenging due to the coupling of a diverse set of physical and biological length and time scales. This report investigates un-certainty quantification methods for such systems that attempt to exploit their structure to gain computational efficiency. The traditional layering of uncertainty quantification around nonlinear solution processes is inverted to allow for heterogeneous uncertainty quantification methods to be applied to each component in a coupled system. Moreover this approach allows stochastic dimension reduction techniques to be applied at each coupling interface. The mathematical feasibility of these ideas is investigated in this report, and mathematical formulations for the resulting stochastically coupled nonlinear systems are developed.

Phipps, Eric Todd↗

Development of an intelligent interface for adding spatial objects to a knowledge-based geographic information system

Earth Scientists lack adequate tools for quantifying complex relationships between existing data layers and studying and modeling the dynamic interactions of these data layers. There is a need for an earth systems tool to manipulate multi-layered, heterogeneous data sets that are spatially indexed, such as sensor imagery and maps, easily and intelligently in a single system. The system can access and manipulate data from multiple sensor sources, maps, and from a learned object hierarchy using an advanced knowledge-based geographical information system. A prototype Knowledge-Based Geographic Information System (KBGIS) was recently constructed. Many of the system internals are well developed, but the system lacks an adequate user interface. A methodology is described for developing an intelligent user interface and extending KBGIS to interconnect with existing NASA systems, such as imagery from the Land Analysis System (LAS), atmospheric data in Common Data Format (CDF), and visualization of complex data with the National Space Science Data Center Graphics System. This would allow NASA to quickly explore the utility of such a system, given the ability to transfer data in and out of KBGIS easily. The use and maintenance of the object hierarchies as polymorphic data types brings, to data management, a while new set of problems and issues, few of which have been explored above the prototype level.

Campbell, William J.↗

Simulator study of the effectiveness of an automatic control system designed to improve the high-angle-of-attack characteristics of a fighter airplane

A piloted, fixed-base simulation was conducted to study the effectiveness of some automatic control system features designed to improve the stability and control characteristics of fighter airplanes at high angles of attack. These features include an angle-of-attack limiter, a normal-acceleration limiter, an aileron-rudder interconnect, and a stability-axis yaw damper. The study was based on a current lightweight fighter prototype. The aerodynamic data used in the simulation were measured on a 0.15-scale model at low Reynolds number and low subsonic Mach number. The simulation was conducted on the Langley differential maneuvering simulator, and the evaluation involved representative combat maneuvering. Results of the investigation show the fully augmented airplane to be quite stable and maneuverable throughout the operational angle-of-attack range. The angle-of-attack/normal-acceleration limiting feature of the pitch control system is found to be a necessity to avoid angle-of-attack excursions at high angles of attack. The aileron-rudder interconnect system is shown to be very effective in making the airplane departure resistant while the stability-axis yaw damper provided improved high-angle-of-attack roll performance with a minimum of sideslip excursions.

Gilbert, W. P.↗