Search NASA⌕ Search

SEARCH · Search NASA

Results for “interface converter”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

709 records · Page 40

Derivation of Effective Properties Based on Porous Scale Simulations Using Filtering Techniques

This study presents a method for derivation of effective properties at the interface and in-depth of porous materials. The method defines a Representative Elementary Volume (REV) and applies filtering techniques to computer effective properties such as porosity and flow quantities, such as velocity and pressure. The script, developed to process the data was tested on the VTK type files that contain the mesh information and the flow solution. The method allows to choose between two types of filters, such as cellular and top-hat and define the size of the REV and number of samples along the domain. Extraction of the REV from the domain is performed to exact boundaries requested for the user. This is done using a triangulation technique and cutting through the cells to comply to the requested boundaries of the volume. The method can be applied to both structured and unstructured meshes. Filtering the material porosity and flow quantities involves integration of the numerical data. The algorithm provides three integration methods, such as Riemann sum, Monte Carlo and Quadrature rule to perform the integration. The Monte-Carlo technique permits the use of either uniform or linearly spaced distribution of points. The Quadrature rule is currently applicable to tetrahedral element types. The Monte Carlo and Quadrature rule methods require interpolation of the flow quantities at the sample points. For interpolation, two methods were tested and are readily available, Gaussian interpolation and re-sampling. It has been shown that re-sampling method has better consistency and acceptable accuracy in interpolation of the data. The algorithm was written in Python language and uses a number of modules. The major module besides numpy is PyVista. It is used to process the computational domain, clip the REV and interpolate the data. Quadrature rule integration was performed using a quadpy module. ParaView software was used externally to convert the flow solution to the VTK (or more specifically VTU) format. Integration of ParaView in the same environment with PyVista encountered problems and could not be implemented in this work. The developed algorithm is expected to be applicable to unstructured meshes and more complex porous structures as soon as the data can be passed in VTK type format. With the report is provided Python script for filtering the solution and a Matlab script for simple generation and processing of 2-D and 3-D porous channel geometries. The two scripts don't communicate.

Alexsander Zibitsker↗

Free-Flying Magnetometer Data System

The Free-Flying Magnetometer (FFM) is an autonomous "sensorcraft" developed at the Jet Propulsion Laboratory (JPL) for the Enstrophy sounding rocket mission. This mission was a collaborative project between the University of New Hampshire, Cornell University and JPL. The science goal of the mission was the study of current filamentation phenomena in the northern auroral region through multipoint measurements of magnetic field. The technical objective of the mission was the proof of concept of the JPL FFM design and the demonstration of an in-situ multipoint measurement technique employing many free-flying spacecraft. Four FFMs were successfully deployed from a sounding rocket launched from Poker Flats, Alaska on February 11, 1999. These hockey-puck-sized (80 mm diameter, 38 mm. height, 250 gram mass) free flyers each carry a miniature 3-axis flux-gate magnetometer that output +/- 2 V signals corresponding to a +/- 60,000 nT measurement range for each axis. The FFM uses a synchronized four-channel Sigma(Delta) Analog-to-Digital Converter (ADC) having a dynamic range of +/- 2.5V and converting at a rate of 279 samples/second/channel. Three channels are used to digitize the magnetometer signals to 17-bit (1.144 nT/bit) resolution. The fourth ADC channel is multiplexed for system monitoring of four temperature sensors and two battery voltages. The FFM also contains two sun sensors, a laser diode which emits a fan-shaped beam, a miniature S-band transmitter for direct communication to the ground station antennas, an ultra-stable Temperature Compensated Crystal Oscillator (TCXO) clock, an integrated data subsystem implemented in a Field-Programmable Gate Array (FPGA), a 4 Mbit Static Random Access Memory (SRAM) for data storage and Lithium Thionyl Chloride batteries for power. Communicating commands to the FFM prior to deployment is achieved with an infrared (IR) link. The FFM IR receiver responds to 9-bit pulse coded signals that are generated by an IR Light Emitting Diode (LED) in the payload for turning FFM power on or off and placing the FFM in a test mode or flight mode. The IR links are also used to synchronize (zero) the clocks onboard all the FFMs through a reset pulse originating from the payload GPS receiver that is issued when the FFMs are in flight mode. The FPGA based data subsystem manages continuous data collection from the four ADC channels and sun sensors, formatting and storing the data to SRAM, and controlling downlink transmission. The transmitter is powered only after a 2547 frame SRAM buffer has been filled (approx. 5 minutes of data). The data is Viterbi encoded and sent to the S-band transmitter via a First-In-First-Out (FIFO) buffer who's output is clocked at 100 bits/second. After the 26-second transmission, the transmitter is turned off to reduce noise coupling to the sensitive magnetometer. The data subsystem control consists of a master state machine that performs data flow management and is interfaced through a prioritized interrupt scheme to state machines that service the ADC, sun sensors and transmitter FIFO. Continuous data collection prevents the missing of data during transmission and provides implicit time tagging of the data acquired by the ADC because of synchronization with the TCXO clock.

Blaes, B.↗

Simulation of DWPF Chemical Process Cell Using a Reaction Calorimeter

The Defense Waste Processing Facility (DWPF) converts liquid radioactive waste into glass using a Sludge Receipt Adjustment Tank (SRAT) and Slurry Mix Evaporator (SME) in addition to other processes. The SRAT and SME processes can be simulated on a small-scale using the Mettler-Toledo Reaction Calorimeter (RC1). This equipment is able to automate the execution and monitoring of experiments involving nonradioactive chemical simulants. During the chemical processing of sludge in the SRAT process, foam begins to form and can foam over the reaction vessel. The current antifoam used at DWPF creates a risk of increased flammability and has a limited pH range. Usually, mercury is circulated back into the reaction vessel during the SRAT process, making it difficult to remove. To combat foam over, novel antifoams will be tested during the boil-up process using the RC1. To improve mercury extraction, 3D-printed coalescer columns will be tested within the Mercury Water Wash Tank (MWWT) of the RC1. Testing of Simulant Sludge Batch 6 (SB6) was performed to ensure: the sludge would form a stable foam at boiling during full SRAT/SME runs; the antifoam would reduce the amount of foam within the vessel The sludge and a Precipitate Reactor Feed Tank (PRFT) simulant with monosodium titanate (MST) were mixed separately, combined, and then heated to boiling. As shown below, the antifoam used was able to eliminate the foam within the vessel, as expected. The FormLabs Form2 3D Printer can be used to create roughly 3-inch tall and 1-inch diameter columns from clear and ceramic resins. The columns will utilize chemical and physical forces to draw the mercury out of a condensed offgas stream leaving the RC1 reaction vessel. These columns will be tested during full SRAT/SME runs on the basis of how well they are able to collect elemental mercury. In preparation for full-scale runs, the RC1 equipment was assembled onto a custom table and tested with water runs. The software used to control automation, iControl, has a user-friendly interface that allows the experiment to be altered as needed. An example of the data recorded during an experimental run is represented in Figure 1 below. Water runs were utilized as a way to prove if the RC1 system was functioning in the following areas: Boil-up rates, Chemical additions using pumps, Temperature readings, Balance readings, Probe readings, Offgas system, Agitation. Future Plans: Five novel antifoams will be tested during full SRAT/SME runs. The most effective antifoam will be utilized in DWPF's Chemical Process Cell. The design of the Mercury Extraction Coalescer can be further manipulated to increase the extraction of not only elemental mercury, but other heavy metals in environmental remediation processes as well.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Microwave Kinetic Inductance Detector with Selective Polarization Coupling

A conventional low-noise detector requires a technique to both absorb incident power and convert it to an electrical signal at cryogenic temperatures. This innovation combines low-noise detector and readout functionality into one device while maintaining high absorption, controlled polarization sensitivity, and broadband detection capability. The resulting far-infrared detectors can be read out with a simple approach, which is compact and minimizes thermal loading. The proposed microwave kinetic inductance detector (MKID) consists of three basic elements. The first is the absorptive section in which the incident power is coupled to a superconducting resonator at far-infrared frequency above its superconducting critical frequency (where superconductor becomes normal conductor). This absorber's shape effectively absorbs signals in the desired polarization state and is resonant at the radio frequency (RF) used for readout of the device. Control over the metal film used in the absorber allows realization of structures with either a 50% broadband or 100% resonance absorptance over a 30% fractional bandwidth. The second element is a microwave resonator - which is realized from the thin metal films used to make the absorber as transmission lines - whose resonance frequency changes due to a variation in its kinetic inductance. The resonator's kinetic inductance is a function of the power absorbed by the device. A low-loss dielectric (mono-crystalline silicon) is used in a parallel-plate transmission line structure to realize the desired superconducting resonators. There is negligible coupling among the adjacent elements used to define the polarization sensitivity of each detector. The final component of the device is a microwave transmission line, which is coupled to the resonator, and allows detection of changes in resonance frequency for each detector in the focal plane array. The spiral shape of the detector's absorber allows incident power with two polarizations to couple to the detector equally. A stepped impedance resonator was used that allows the incident power absorbed in the detecting membrane area to be uniformly distributed in the detector's transmission line at the RF readout frequency. This maximizes the sensitivity of the detector. The signal is read out via a frequency multiplexing technique that requires a minimum number of interface transmission lines for readout. This reduces the packaging complexity and coupling to the device's thermal environment.

Wollack, Edward↗

X-57 Cockpit Interface Control Document (ICD-CEPT-006)

The Cockpit Interface Control Document defines the hardware interfaces between the X-57 cockpit and subsystems. It provides locational and operational information in support of ground and flight operations with details on controls and displays that include Modes of Operation, Start-Up and Shut- Down Sequence diagrams and captures the current state of the MOD II Avionics Power Architecture. There is also preliminary information of the MOD III and MOD IV configurations. Microsoft PowerPoint was chosen for the document as early development required frequent meetings with multiple customers including aircraft operators (pilots), ground operations, support contractors and power, instrumentation, and human systems integration engineers and PowerPoint enabled presentations that could be quickly modified based on customer and developer interaction. One of the driving requirements for the cockpit design was to keep the left side panel as close the stock Tecnam panel as possible to reduce the failure risk of flight critical indicators. The original annunciator panel in the left side panel was modified to alert the pilot to failures in critical X-57 subsystems and an operator audio alert capability was added for these subsystems. Power-Up switches for the aircraft low voltage 13.8 VDC systems are located at the bottom of the left side panel and center panel, the same location as the stock Tecnam 13.8 VDC switches. The switches for energizing the high voltage system were located in the overhead panel to reduce the risk of inadvertently energizing the high voltage system during the low voltage power-up sequence. The Cruise Motor ARM switches were also located in the overhead panel and correspond to the same location as the stock Tecnam ignition switches. The stock Tecnam throttle levers and prop pitch levers were retained for the X-57. The throttle levers were renamed torque levers since they controlled the commanded torque to the cruise motors. The prop pitch levers provide a commanded RPM signal to an electronic prop pitch controller. X-57 specific displays, located in the right-side panel, are driven by dedicated sensors that monitor right and left side cruise motor RPM, right and left high voltage “Traction Bus” A and B (voltage, current and power) and the Avionics Bus DC converters (A and B) voltage and current. An X-57 Multi-Function Display (MFD) located in the center panel displays CAN Bus parameters. CAN Bus architecture is not certified for flight so these displays could not be used for safety critical information but were designed to be used for test point information only.

Laura Kushner↗

Stability and control of power systems with high penetrations of inverter-based resources: An accessible review of current knowledge and open questions

As power system renewable energy penetrations increase, the ways in which key renewable technologies such as wind and solar photovoltaics (PV) differ from thermal generators become more apparent. Many studies have examined the variability and uncertainty of such generators and described how generation and load can be balanced for a wide variety of annual energy penetrations, at timescales from seconds to years. Another important characteristic of these resources is asynchronicity, the result of using inverters to interface the prime energy source with the power system as opposed to synchronous generators. Unlike synchronous generators, whose frequency of alternating current (AC) injection is physically coupled to the rotation of the machine itself, inverter based asynchronous generators do not share the same physical coupling with the generated frequency. These subtle differences impact the operations of power systems developed around the characteristics of synchronous generators. In this paper we review current knowledge and open research questions concerning the interplay between asynchronous inverter-based resources (IBRs) and cycle- to second-scale power system dynamics, with a focus on how stability and control may be impacted or need to be achieved differently when there are high instantaneous penetrations of IBRs across an interconnection. This work does not seek to provide a comprehensive review of the latest developments, but is instead intended to be accessible to any reader with an engineering background and an interest in power systems and renewable energy. As such, the paper includes basic material on power electronics, control schemes for IBRs, and power system stability; and uses this background material to describe potential impacts of IBRs on power system stability, operational challenges associated with large amounts of distributed IBR generation, and modern power system simulation trends driven by IBR characteristics.

14 SOLAR ENERGY↗

Through‐Plane Conductive Hydrophobic Electrodes for CO 2 Electrolysis to Ethylene

Copper catalyst gas diffusion electrodes (GDEs) have demonstrated unique electrochemical selectivity converting CO 2 to C 2 -hydrocarbons such as ethylene and ethanol but have been challenged by their hydrophobic chemical stability and internal electrical resistance leading to low energy efficiency. Carbon-supported GDEs have low electrical resistance but lack sufficient stability at industrially relevant current densities. While polymer-supported GDEs have improved hydrophobicity, they also display high in-plane electrical resistance, particularly at industrial scales. Here, in this work, we demonstrate a composite gas diffusion layer that combines hydrophobic porous polymers with an electrically conductive backbone addressing these core gas diffusion electrode (GDE) scaling challenges. We investigate the material properties of standalone porous perfluoropolyether (PFPE) polymers, including porosity and surface morphology, under varying processing conditions and then incorporate these polymers into a porous copper foam. This composite enhances the mechanical rigidity necessary for cell assembly and provides a through-plane electrical conduction path to reduce electrical resistive losses. This enhanced PFPE composite GDE displays efficient CO 2 reduction, achieving 15% ethylene energy efficiency at 100 cm 2 . These findings contribute to the development of advanced catalyst materials and electrode architectures and promote scalable strategies for electrochemical conversion of CO 2 into high-value carbon products.

Chemistry↗