Search NASA⌕ Search

SEARCH · Search NASA

Results for “ionization efficiency”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 721 records · Page 40

Development and clinical evaluation of an ionization chamber array with 3.5 mm pixel pitch for quality assurance in advanced radiotherapy techniques

Purpose: To characterize a new air vented ionization chamber technology, suitable to build detector arrays with small pixel pitch and independence of sensitivity on dose per pulse. Methods: The prototype under test is a linear array of air vented ionization chambers, consisting of 80 pixels with 3.5 mm pixel pitch distance and a sensitive volume of about 4 mm{sup 3}. The detector has been characterized with {sup 60}Co radiation and MV x rays from different linear accelerators (with flattened and unflattened beam qualities). Sensitivity dependence on dose per pulse has been evaluated under MV x rays by changing both the source to detector distance and the beam quality. Bias voltage has been varied in order to evaluate the charge collection efficiency in the most critical conditions. Relative dose profiles have been measured for both flattened and unflattened distributions with different field sizes. The reference detectors were a commercial array of ionization chambers and an amorphous silicon flat panel in direct conversion configuration. Profiles of dose distribution have been measured also with intensity modulated radiation therapy (IMRT), stereotactic radiosurgery (SRS), and volumetric modulated arc therapy (VMAT) patient plans. Comparison has been done with a commercial diode array and with Gafchromic EBT3 films. Results: Repeatability and stability under continuous gamma irradiation are within 0.3%, in spite of low active volume and sensitivity (∼200 pC/Gy). Deviation from linearity is in the range [0.3%, −0.9%] for a dose of at least 20 cGy, while a worsening of linearity is observed below 10 cGy. Charge collection efficiency with 2.67 mGy/pulse is higher than 99%, leading to a ±0.9% sensitivity change in the range 0.09–2.67 mGy/pulse (covering all flattened and unflattened beam qualities). Tissue to phantom ratios show an agreement within 0.6% with the reference detector up to 34 cm depth. For field sizes in the range 2 × 2 to 15 × 15 cm{sup 2}, the output factors are in agreement with a thimble chamber within 2%, while with 25 × 25 cm{sup 2} field size, an underestimation of 4.0% was found. Agreement of field and penumbra width measurements with the flat panel is of the order of 1 mm down to 1 × 1 cm{sup 2} field size. Flatness and symmetry values measured with the 1D array and the reference detectors are comparable, and differences are always smaller than 1%. Angular dependence of the detector, when compared to measurements taken with a cylindrical chamber in the same phantom, is as large as 16%. This includes inhomogeneity and asymmetry of the design, which during plan verification are accounted for by the treatment planning system (TPS). The detector is capable to reproduce the dose distributions of IMRT and VMAT plans with a maximum deviation from TPS of 3.0% in the target region. In the case of VMAT and SRS plans, an average (maximum) deviation of the order of 1% (4%) from films has been measured. Conclusions: The investigated technology appears to be useful both for Linac QA and patient plan verification, especially in treatments with steep dose gradients and nonuniform dose rates such as VMAT and SRS. Major limitations of the present prototype are the linearity at low dose, which can be solved by optimizing the readout electronics, and the underestimation of output factors with large field sizes. The latter problem is presently not completely understood and will require further investigations.

60 APPLIED LIFE SCIENCES↗

The Planetary Accretion Shock. I. Framework for Radiation-hydrodynamical Simulations and First Results

The key aspect determining the postformation luminosity of gas giants has long been considered to be the energetics of the accretion shock at the surface of the planet. We use one-dimensional radiation-hydrodynamical simulations to study the radiative loss efficiency and to obtain postshock temperatures and pressures and thus entropies. The efficiency is defined as the fraction of the total incoming energy flux that escapes the system (roughly the Hill sphere), taking into account the energy recycling that occurs ahead of the shock in a radiative precursor. We focus in this paper on a constant equation of state (EOS) to isolate the shock physics but use constant and tabulated opacities. While robust quantitative results will have to await a self-consistent treatment including hydrogen dissociation and ionization, the results presented here show the correct qualitative behavior and can be understood from semianalytical calculations. The shock is found to be isothermal and supercritical for a range of conditions relevant to the core accretion formation scenario (CA), with Mach numbers M≳3. Across the shock, the entropy decreases significantly by a few times k{sub B}/baryon. While nearly 100% of the incoming kinetic energy is converted to radiation locally, the efficiencies are found to be as low as roughly 40%, implying that a significant fraction of the total accretion energy is brought into the planet. However, for realistic parameter combinations in the CA scenario, we find that a nonzero fraction of the luminosity always escapes the Hill sphere. This luminosity could explain, at least in part, recent observations in the young LkCa 15 and HD 100546 systems.

79 ASTRONOMY AND ASTROPHYSICS↗

Electric field distribution in a non-self-sustained RF discharge with ionization generated by Ns discharge pulses

Abstract Electric field in a capacitively coupled, non-self-sustained RF discharge nitrogen plasma with external ionization generated by high-voltage ns pulses has been measured by ps Electric field induced second harmonic generation (EFISH). The measurements are made both in the bulk of the plasma and in the sheaths, using the absolute calibration by the Laplacian field between two plane electrodes. The results are compared with the kinetic modeling calculations. The RF electric field in the sheaths is significantly higher compared to that in the plasma, due to the displacement of the electrons by the drift oscillations and the resultant plasma self-shielding. However, the kinetic modeling predictions indicate that the electron impact ionization in the sheaths is largely ineffective, due to the low electron density. The reduction of the electric field in the plasma by the self-shielding in the sheaths is moderate, such that the energy is coupled to the plasma by the below-breakdown RF field. The peak RF field in the plasma is in the range of 15–25 Td, indicating the efficient vibrational excitation of N 2 by electron impact. The modeling predictions suggest that the targeted vibrational excitation of molecular species in a non-self-sustained RF discharge with external ionization is scalable to high pressures, electron densities, and discharge powers. The present approach can be extended to the vibrational excitation of other molecular species where the vibrational relaxation is relatively slow, such as CO, CO 2 , and H 2 .

Physics↗

Ternary Organic Solar Cells with Minimum Voltage Losses

Abstract A new strategy for designing ternary solar cells is reported in this paper. A low‐bandgap polymer named PTB7‐Th and a high‐bandgap polymer named PBDTTS‐FTAZ sharing the same bulk ionization potential and interface positive integer charge transfer energy while featuring complementary absorption spectra are selected. They are used to fabricate efficient ternary solar cells, where the hole can be transported freely between the two donor polymers and collected by the electrode as in one broadband low bandgap polymer. Furthermore, the fullerene acceptor is chosen so that the energy of the positive integer charge transfer state of the two donor polymers is equal to the energy of negative integer charge transfer state of the fullerene, enabling enhanced dissociation of all polymer donor and fullerene acceptor excitons and suppressed bimolecular and trap assistant recombination. The two donor polymers feature good miscibility and energy transfer from high‐bandgap polymer of PBDTTS‐FTAZ to low‐bandgap polymer of PTB7‐Th, which contribute to enhanced performance of the ternary solar cell.

Wang, Chuanfei↗

Development of position-sensitive time-of-flight spectrometer for fission fragment research

A position-sensitive, high-resolution time-of-flight detector for fission fragments has been developed. The SPectrometer for Ion DEtermination in fission Research (SPIDER) is a 2E–2v spectrometer designed to measure the mass of light fission fragments to a single mass unit. The time pick-off detector pairs to be used in SPIDER have been tested with α-particles from 229Th and its decay chain and α-particles and spontaneous fission fragments from 252Cf. Each detector module is comprised of thin electron conversion foil, electrostatic mirror, microchannel plates, and delay-line anodes. Particle trajectories on the order of 700 mm are determined accurately to within 0.7 mm. Flight times were measured with 250 ps resolution FWHM. Computed particle velocities are accurate to within 0.06 mm/ns corresponding to a precision of 0.5%. As a result, an ionization chamber capable of 400 keV energy resolution coupled with the velocity measurements described here will pave the way for modestly efficient measurements of light fission fragments with unit mass resolution.

2E-2v↗

The anatomy of the minority carrier - atomic cluster interaction in semiconductors

This project was to use light ion beam induced charge (IBIC) to detect damage cascades generated by a single heavy ion, and thereby reveal details of the shape of the cascade and the physics of recombination of carriers that interact with the cluster. Further IBIC measurements using the hardware and software of this project will improve the accuracy of theoretical models used to predict electrical degradation in devices exposed to radiation environments. In addition, future use of light ion IBIC detection of single ion-induced damage could be used to locate single ion implantation sites in quantum computing applications. This project used Sandia's Pelletron and nanoImplanter (nI) to produce heavy ion-induced collision cascades in p-n diodes, simulating cascades made by primary knock-on atoms recoiled by neutrons. Si and Li beams from the nI were used to perform highly focused scans generating IBIC signal maps where regions of lower charge collection efficiency were observed without incurring further damage. The very first use of ion channeled beams for IBIC was explored to maximize ionization, improve contrast and provide very straight line trajectories to improve lateral resolution.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Highly Polarized Ion Sources for Electron Ion Colliders (EIC)

The operation of the RHIC facility at BNL and the Electron Ion Colliders (EIC) under development at Jefferson Laboratory and BNL need high brightness ion beams with the highest polarization. Charge exchange injection into a storage ring or synchrotron and Siberian snakes have the potential to handle the needed polarized beam currents, but first the ion sources must create beams with the highest possible polarization to maximize collider productivity, which is proportional to a high power of the polarization. We are developing one universal H-/D- ion source design which will synthesize the most advanced developments in the field of polarized ion sources to provide high current, high brightness, ion beams with greater than 90% polarization, good lifetime, high reliability, and good power efficiency. The new source will be an advanced version of an atomic beam polarized ion source (ABPIS) with resonant charge exchange ionization by negative ions. An integrated ABPIS design will be prepared based on new materials and an optimized magnetic focusing system. Polarized atomic and ion beam formation, extraction, and transport for the new source will be computer simulated.

43 PARTICLE ACCELERATORS↗

Atmospheric Solid Analysis Probe Coupled to Ion Mobility Spectrometry-Mass Spectrometry, a Fast and Simple Method for Polyalphaolefin Characterization

Polyalphaolefins (PAOs) are polymers produced from linear alpha olefins through catalytic oligomerization processes. The PAOs are known as synthetic high-performance base stock fluids used to improve the efficiency of many other synthetic products. In this study, we report the direct characterization of PAOs using atmospheric solid analysis probe (ASAP) coupled with ion mobility spectrometry-mass spectrometry (IMS-MS). We studied different PAOs grades exhibiting low- and high-viscosity index. Specific adjustments of the ASAP source parameters permitted the monitoring of ionization processes as three mechanisms could occur for these compounds: hydride abstraction, nitrogen addition, and/or the formation of [M−2H]{sup +•} ions. Several series of fragment ions were obtained, which allowed the identification of the alpha olefin used to synthesize the PAO. The use of the ion mobility separation dimension provides information on isomeric species. In addition, the drift time versus m/z plots permitted rapid comparison between PAO samples and to evidence their complexity. These 2D plots appear as fingerprints of PAO samples. To conclude, the resort to ASAP-IMS-MS provides a rapid characterization of the PAO samples in a direct analysis approach, without any sample preparation. .

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Resolved Molecular Gas Observations of MaNGA Post-starbursts Reveal a Tumultuous Past

Post-starburst (PSB) galaxies have recently and rapidly quenched their star formation; thus, they are an important way to understand how galaxies transition from star-forming late types to quiescent early types. The recent discovery of large cold gas reservoirs in PSB galaxies calls into question the theory that galaxies must lose their gas to become quiescent. Optical Integral Field Spectroscopy (IFS) surveys have revealed two classes of PSB galaxies: central PSB (cPSB) galaxies with central quenching regions and ring PSB (rPSB) galaxies with quenching in their outskirts. We analyze a sample of 13 nearby (z < 0.1) PSB galaxies with spatially resolved optical IFS data from the Mapping Nearby Galaxies at Apache Point Observatory survey and matched resolution Atacama Large Millimeter/submillimeter Array observations of 12 CO(1–0). Disturbed stellar kinematics in 7/13 of our PSB galaxies and centrally concentrated molecular gas is consistent with a recent merger for most of our sample. In galaxies without merger evidence, alternate processes may funnel gas inward and suppress star formation, which may include outflows, stellar bars, and minor mergers or interactions. The star formation efficiencies of the PSB regions in nearly half our galaxies are suppressed while the gas fractions are consistent with star-forming galaxies. Active galactic nucleus (AGN) feedback may drive this stabilization, and we observe AGN-consistent emission in the centers of 5/13 galaxies. Finally, our cPSB and rPSB galaxies have similar properties except the ionized and molecular gas in cPSB galaxies is more disturbed. Overall, the molecular gas in our PSB galaxies tends to be compact and highly disturbed, resulting in concentrated gas reservoirs unable to form stars efficiently.

79 ASTRONOMY AND ASTROPHYSICS↗

Surface hopping investigation of the relaxation dynamics in radical cations

Ionization processes can lead to the formation of radical cations with population in several ionic states. In this study, we examine the dynamics of three radical cations starting from an excited ionic state using trajectory surface hopping dynamics in combination with multiconfigurational electronic structure methods. The efficiency of relaxation to the ground state is examined in an effort to understand better whether fragmentation of cations is likely to occur directly on excited states or after relaxation to the ground state. The results on cyclohexadiene, hexatriene, and uracil indicate that relaxation to the ground ionic state is very fast in these systems, while fragmentation before relaxation is rare. Ultrafast relaxation is facilitated by the close proximity of electronic states and the presence of two- and three-state conical intersections. Examining the properties of the systems in the Franck-Condon region can give some insight into the subsequent dynamics.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Effective design of multiple hollow cathode electrode to enhance the density of rf capacitively coupled plasma

Multiple-hole electrode rf capacitively coupled plasma is experimentally studied to determine the optimum condition for high-density plasma discharge. The plasma density was measured at various pressures, hole diameters, rf currents, and gas species conditions. The bulk plasma intrusion in the hole and the ionization avalanche in the sheath region facilitated high-density plasma generation when the diameter of the hole is slightly wider than triple the sheath length. The analytic design of the efficient multihole electrode for high-density rf capacitively coupled plasma discharge will be discussed.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Cold ion UV photofragmentation spectroscopy and dynamics (Invited)

Up to ten years ago, very little was known about the excited states of protonated amino acids isolated in the gas phase. From the experimental point of view, the study was hampered by the lack of ease of production of such species in sufficient density to apply photon-based techniques. With the development and widespread use of electrospray ionization sources coupled with modified or homebuilt mass spectrometers, there has been significant research into the spectroscopy of biomimetic and biologically relevant molecules. Besides, these species are floppy such that an efficient cooling is required to record clear spectroscopy. Warm protonated species display congested spectra. To extract precise spectroscopic information and avoid spectral congestion, the species need to be cooled down to less than 50 K. We present our latest results on the electronic spectroscopy of protonated phenylalanine and tyrosine on a large spectral domain (225-290 nm). These species are studied in a new simplified apparatus combining an electrospray ionization source, a cryogenically cooled quadrupole ion trap (∼10 K) and time-of-flight mass spectrometry. The role of proton transfer from the NH{sub 3}{sup +} moiety to the p-ring or to CO of the carboxylic acid group is evidenced by UV photofragment spectroscopy. This first step controls the fragmentation pathways, which strongly depend on the nature of the electronic excited states, i.e. ππ*, ππ*{sub CO} and πσ{sub NH3}.

74 ATOMIC AND MOLECULAR PHYSICS↗

Ionic wind generation by a wire-cylinder-plate corona discharge in air at atmospheric pressure

A wire-cylinder-plate electrode configuration is presented to generate ionic wind with a dc corona discharge in air at atmospheric pressure. The objective of the work is to maximize the power supplied to the flow in order to increase acceleration while avoiding breakdown. Thus, the proposed experimental setup addresses the problem of decoupling the mechanism of ion generation from that of ion acceleration. Using a wire-plate configuration as a reference, we have focused on improving the topography of the electric field to (1) separate the ionization and acceleration zones in space, and (2) guide the trajectory of charged particles as parallel to the median axis as possible. In the proposed wire-cylinder-plate setup, a dc corona discharge is generated in the space between a wire and two cylinders. The ions produced by the corona then drift past the cylinders and into a channel between two plates, where they undergo acceleration. To maximize the ionic wind it is found that the geometric configuration must be as compact as possible and that the voltage applied must be right below breakdown. Experimentally, the optimized wire-plate reference setup provides a maximum flow velocity of 8 m s{sup -1}, a flow rate per unit electrode length of 0.034 m{sup 2} s{sup -1}, and a thrust per unit electrode length of 0.24 N m{sup -1}. The wire-cylinder-plate configuration provides a maximum flow velocity of 10 m s{sup -1}, a flow rate per unit electrode length of 0.041 m{sup 2} s{sup -1}, and a thrust per unit electrode length of 0.35 N m{sup -1}. This 46% increase in thrust is obtained by increasing the electric power per unit electrode length by only 16% (from 175 to 210 W m{sup -1}), which confirms the gain in efficiency obtained with the decoupled system. In comparison with a simple wire-wire corona configuration, the wire-cylinder-plate configuration increases the ionic wind velocity by up to a factor of 3, and the thrust by an order of magnitude.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Influence of the Rheology Behavior of Water-Soluble Polyacrylamides and Their Efficiency of Flocculation

Organic polymers such as water-soluble polyacrylamides that are used as flocculants in solid–liquid separations, have their flocculation efficiency determined by the behavior of their macromolecules in solution. This behavior is affected by its intrinsic characteristics, especially the presence of ionic groups in its macromolecules. In this context, the present work aimed to characterize three water-soluble polyacrylamides. The effect of the intrinsic properties of each polymer on the behavior of the polymer chains in aqueous solution was compared in different environments. Beside this, the polymers behavior effect on the destabilization of particles was evaluated through kaolin particle aggregation studies. Viscosity results show that the conformation of the macromolecules in solution is altered according to the amount of ionized groups present. This variation, together with other factors such as the affinity with the kaolin particles and the excess of ions in solution, reflects in the flocculation efficiency of kaolin particles, in the flocs size and the flocs sedimentation rate. Graphic Abstract: .

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

A New Light Weight Structural Material for Nuclear Structures

Radiation shielding materials are commonly used in nuclear facilities to attenuate the background ionization radiations to a minimum level for creating a safer workplace, meeting regulatory requirements and maintaining high quality performance. The conventional radiation shielding materials have a number of drawbacks: heavy concrete contains a high amount of elements that are not desirable for an effective shielding such as oxygen, silicon, and calcium; a well known limitation of lead is its low machinability and toxicity, which is causing a major environmental concern. Therefore, an effective and environmentally friendly shielding material with increased attenuation and low mass density is desirable. Close-cell composite metal foams (CMFs) and open-cell Al foam with fillers are light-weight candidate materials that we have studied in this project. Close-cell CMFs possess several suitable properties that are unattainable by conventional radiation shielding materials such as low density and high strength for structural applications, high surface area to volume ratio for excellent thermal isolation with an extraordinary energy absorption capability. Open-cell foam is made up of a network of interconnected solid struts, which allows gas or fluid media to pass through it. This unique structure provided a further motive to investigate its application as radiation shields by infiltrating original empty pores with high hydrogen or boron compounds, which are well known for their excellent neutron shielding capability. The resulting open-cell foam with fillers will not only exhibit light weight and high specific surface area, but also possess excellent radiation shielding capability and good processability. In this study, all the foams were investigated for their radiation shielding efficiency in terms of X-ray, gamma ray and neutron. X-ray transmission measurements were carried out on a high-resolution microcomputed tomography (microCT) system. Gamma-emitting sources: 3.0mCi 60 Co, 1.8mCi 137 Cs, 13.5mCi 241 Am, and 5.0mCi 133 Ba were used for gamma-ray attenuation analysis. The evaluations of neutron transmission measurements were conducted at the Neutron Powder Diffractometer beam facility at North Carolina State University. The experimental results were verified theoretically through XCOM and Monte Carlo Z-particle Transport Code (MCNP). A mechanical investigation was performed by means of quasi-static compressive testing. Thermal characterizations were carried out through effective thermal conductivity and thermal expansion analyses in terms of high temperature guarded-comparative-longitudinal heat flow technique and thermomechanical analyzer (TMA), respectively. The experimental results were compared with analytical results obtained from, respectively, Brailsford and Major’s model and modified Turner’s model for verification. Flame test was performed in accordance with United States Nuclear Regulatory Commission (USNRC) standard. CMF sample and a 304L stainless steel control sample were subjected to a fully engulfing fire with an average flame temperature of 800°C for a period of 30 minutes. Finite Element Analysis was conducted to secure the credibility of the experimental results. This research indicates the potential of utilizing the light-weight close-cell CMFs and open-cell Al foam with fillers as shielding material replacing current heavy structures with additional advantage of high-energy absorption and excellent thermal characteristics.

36 MATERIALS SCIENCE↗

Improved Scintillator Materials for Compact Electron Antineutrino Detectors

Developments in the fields of chemistry and materials science provide new components that hold the potential to improve the performance of liquid scintillation electron antineutrino detectors used for the monitoring of nuclear reactors. New compounds can provide for more efficient, stable, and safer operation of these detectors. Current detectors and their detector materials raise issues regarding size, quantum efficiency, stability, and spatial resolution for the vertex detection. For compact detectors (1 m{sup 3} active volume) improvement of these issues with existing liquid scintillation cocktails can be obtained by means of developing stable and efficient neutron capture agents. These agents comprise of boron or lithium containing coordination compounds, in addition advances in fluorescence detection technologies and optimization of solvent characteristics can improve the overall efficiency. Focus points of the new detector material design are to enable a compact, robust, and direction sensitive electron antineutrino detector.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Efficiency enhancement of a two-beam free-electron laser

A local and nonlinear simulation of two-beam and tapered free-electron laser (FEL) is presented self-consistently. The slippage of the electromagnetic wave with respect to the electron beam is ignored and the relativistic electron beams are assumed to be cold. The fundamental resonance and the third harmonic radiation of the beam with lower energy are considered, in which the third harmonic is at the fundamental resonance of the beam with higher energy. The wiggler field is set to decrease linearly when the radiation of the third harmonic saturates. The optimum starting point of tapering and the slope of the reduction in the amplitude of wiggler are found by successive run of the code. Using the slowly varying envelope approximation, a set of nonlinear equations is derived which describes this system. These equations are solved numerically by the Runge-Kutta method. This method can be used to improve the efficiency of the two-beam FEL in the extreme ultraviolet and x-ray regions of spectrum.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Iron distribution in silicon after solar cell processing: Synchrotron analysis and predictive modeling

The evolution during silicon solar cell processing of performance-limiting iron impurities is investigated with synchrotron-based x-ray fluorescence microscopy. We find that during industrial phosphorus diffusion, bulk precipitate dissolution is incomplete in wafers with high metal content, specifically ingot border material. Postdiffusion low-temperature annealing is not found to alter appreciably the size or spatial distribution of FeSi{sub 2} precipitates, although cell efficiency improves due to a decrease in iron interstitial concentration. Gettering simulations successfully model experiment results and suggest the efficacy of high- and low-temperature processing to reduce both precipitated and interstitial iron concentrations, respectively.

36 MATERIALS SCIENCE↗