Search NASA⌕ Search

SEARCH · Search NASA

Results for “matched field processing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 721 records · Page 40

Potential scenarios for broadening stakeholder involvement in the implementing geological disposal technology platform

This paper analyses the potential for the involvement of different types of stakeholders in the Implementing Geological Disposal Technology Platform (IGD-TP). This analysis was conducted as part of the InSOTEC project, a three-year (2011- 2014) collaborative research project funded under the 7. Euratom Framework Programme (Grant Agreement nr. 269906). In our analysis, we consider the extent to which the IGDTP's practice as regards to stakeholder involvement matches its discourse, and what potential for improvement exists given its structural organisation as a European Technology Platform (ETPs). Technology Platforms (TPs) can be understood as knowledge networks, deliberately set up to influence (research) policy in a specific domain. We therefore use knowledge networks as a conceptual approach and look at the IGD-TP as a complex network which includes actors, knowledge and practices across different countries, focusing on a very specific topic (i.e. implementing geological disposal). We compare the way different stakeholders are involved in the IGD-TP to the practice of other ETPs, and explore how the IGD-TP is viewed by its members and by outsiders to the platform Applying Callon's framework of knowledge co-production (1999) we come to define different degrees of interaction between science, society and policy in view of defining research and development (R and D) priorities [1]. Subsequently we describe how these interactions could be conceptualised and interpreted for the IGD-TP. The current approach of the IGDTP can be mainly understood as classical model involving mainly expert stakeholders and scientists. Where there seems to be a good representation among IGD-TP members of industry, research institutes, and some members of the academic community this is not the case for other types of stakeholders, such as public authorities or civil society. At this stage, the overall approach of the IGD-TP would seem to restrict the scope of stakeholder involvement, as it narrows participation down to uniquely technology experts, hindering socio-technical manifestations. Our analysis nevertheless shows that there is room for engaging with a broader range of stakeholders in the field of radioactive waste management, if this is the intention of the IGD-TP. However, this would require a commitment to developing a common knowledge base including other stakeholders through a process of mutual adjustment and negotiation. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

unWISE: Unblurred coadds of the WISE imaging

The Wide-field Infrared Survey Explorer (WISE) satellite observed the full sky in four mid-infrared bands in the 2.8-28 μm range. The primary mission was completed in 2010. The WISE team has done a superb job of producing a series of high-quality, well-documented, complete data releases in a timely manner. However, the 'Atlas Image' coadds that are part of the recent AllWISE and previous data releases were intentionally blurred. Convolving the images by the point-spread function while coadding results in 'matched-filtered' images that are close to optimal for detecting isolated point sources. But these matched-filtered images are sub-optimal or inappropriate for other purposes. For example, we are photometering the WISE images at the locations of sources detected in the Sloan Digital Sky Survey through forward modeling, and this blurring decreases the available signal-to-noise by effectively broadening the point-spread function. This paper presents a new set of coadds of the WISE images that have not been blurred. These images retain the intrinsic resolution of the data and are appropriate for photometry preserving the available signal-to-noise. Users should be cautioned, however, that the W3- and W4-band coadds contain artifacts around large, bright structures (large galaxies, dusty nebulae, etc.); eliminating these artifacts is the subject of ongoing work. These new coadds, and the code used to produce them, are publicly available at http://unwise.me.

79 ASTRONOMY AND ASTROPHYSICS↗

TRUST Sensors in Environments: Thermocouples (SE-TC), Release FY25

The Delivery Environments Testbeds to Reduce Uncertainty in Simulations and Tests (TRUST) project is a broad project intended to analyze simplified problems experimentally and with modeling and simulation. The purpose of analyzing these simplified problems is to extend solution methods to more complex problems, as well as understand deficiencies and gaps in knowledge of methods currently used in more complex analyses. The TRUST project encompasses several smaller testbeds intended to isolate individual phenomena. The testbed under consideration in this report is the Sensors in Environments: Thermocouples testbed. In previous years, the purpose of this testbed was to quantify uncertainty of thermocouple sensors. To accomplish this, an aluminum plate was placed in a thermal chamber and subject to various types of thermal loading. Thermocouples were placed in various locations on the aluminum plate in various configurations (e.g., embedded in the plate, placed under Kapton tape), and an effort was made to quantify uncertainty in these measurements. Finite element simulations were performed to investigate how sensitive these measurements were to parameters such as the boundary conditions on the plate and material properties. However, a fundamental source of uncertainty in this analysis was the convective heat transfer from the plate. Convective heat transfer is a complex physical phenomenon comprised of a number of interacting sub-processes and is difficult to predict accurately a priori. As such, the main purpose of this testbed in FY25 was to better understand, both experimentally and numerically, the convective heat transfer from the plate. This is a highly applicable problem to several more complex problems, as convective heat transfer occurs in nearly all problems where a body is moving through air. Numerically, this required a two-step approach. First, the air flow in the thermal chamber was in vestigated using computational fluid dynamics. The commercial solver Fluent was used to perform these simulations. From these simulations, a heat transfer coefficient over the surface of the plate was calculated. This heat transfer was then used as boundary conditions for finite element heat transfer simulations within the plate, which were performed using Abaqus. Significant effort was devoted to automating the handoff between these two solvers. Experimentally, previous thermocouple results in the plate were used to validate the time-dependent thermal profiles produced from Abaqus. Further experimental efforts were performed both to help validate the Fluent simulations and to inform its boundary conditions. For example, hot-wire anemometers were used to measure the velocity in the chamber, which would be particularly useful in understanding the chamber inlet velocity. Thermocouple measurements were also taken in the chamber, instead of only on the plate, to serve as validation evidence for the Fluent simulations. Numerical results showed that the Fluent to Abaqus workflow matched previous plate thermocouple measurements well. This type of handoff is useful for more complex experiments, or those that are not able to be examined in as great of detail as this testbed, as it was performed without any experimental input. Experimental results, however, were more mixed. The anemometers proved unreliable, with inconsistent measurements across all anemometers, even at locations that were nearly identical. On the other hand, the thermocouples provided a relatively rich view of the temperature field in the chamber.

42 ENGINEERING↗

Scalable Parallel Methods for Analyzing Metagenomics Data at Extreme Scale

The field of bioinformatics and computational biology is currently experiencing a data revolution. The exciting prospect of making fundamental biological discoveries is fueling the rapid development and deployment of numerous cost-effective, high-throughput next-generation sequencing technologies. The result is that the DNA and protein sequence repositories are being bombarded with new sequence information. Databases are continuing to report a Moore’s law-like growth trajectory in their database sizes, roughly doubling every 18 months. In what seems to be a paradigm-shift, individual projects are now capable of generating billions of raw sequence data that need to be analyzed in the presence of already annotated sequence information. While it is clear that data-driven methods, such as sequencing homology detection, are becoming the mainstay in the field of computational life sciences, the algorithmic advancements essential for implementing complex data analytics at scale have mostly lagged behind. Sequence homology detection is central to a number of bioinformatics applications including genome sequencing and protein family characterization. Given millions of sequences, the goal is to identify all pairs of sequences that are highly similar (or “homologous”) on the basis of alignment criteria. While there are optimal alignment algorithms to compute pairwise homology, their deployment for large-scale is currently not feasible; instead, heuristic methods are used at the expense of quality. In this dissertation, we present the design and evaluation of a parallel implementation for conducting optimal homology detection on distributed memory supercomputers. Our approach uses a combination of techniques from asynchronous load balancing (viz. work stealing, dynamic task counters), data replication, and exact-matching filters to achieve homology detection at scale. Results for a collection of 2.56M sequences show parallel efficiencies of ~75-100% on up to 8K cores, representing a time-to-solution of 33 seconds. We extend this work with a detailed analysis of single-node sequence alignment performance using the latest CPU vector instruction set extensions. Preliminary results reveal that current sequence alignment algorithms are unable to fully utilize widening vector registers.

59 BASIC BIOLOGICAL SCIENCES↗

SU-E-T-812: Volumetric Modulated Arc Therapy-Total Body Irradiation (VMAT-TBI) V.s. Conventional Extended SSD-TBI (cTBI): A Dosimetric Comparisom

Purpose: To perform a dosimetric evaluation on a new developed volumetric modulated arc therapy based total body irradiation (VMAT-TBI). Methods: Three patients were CT scanned with an indexed rotatable body frame to get whole body CT images. Concatenated CT images were imported in Pinnacle treatment planning system and whole body and lung were contoured as PTV and organ at risk, respectively. Treatment plans were generated by matching multiple isocenter volumetric modulated arc (VMAT) fields of the upper body and multiple isocenter parallel-opposed fields of the lower body. For each plan, 1200 cGy in 8 fractions was prescribed to the whole body volume and the lung dose was constrained to a mean dose of 750 cGy. Such a two-level dose plan was achieved by inverse planning of the torso VMAT fields. For comparison, conventional standing TBI (cTBI) plans were generated on the same whole body CT images at an extended SSD (550cm).The shape of compensators and lung blocks are simulated using body segments and lung contours Compensation was calculated based on the patient CT images, in mimic of the standing TBI treatment. The whole body dose distribution of cTBI plans were calculated with a home-developed GPU Monte Carlo dose engine. Calculated cTBI dose distribution was prescribed to the mid-body point at umbilical level. Results: The VMAT-TBI treatment plans of three patients’ plans achieved 80.2%±5.0% coverage of the total body volume within ±10% of the prescription dose, while cTBI treatment plans achieved 72.2%±4.0% coverage of the total body volume. The averaged mean lung dose of all three patients is lower for VMAT-TBI (7.48 cGy) than for cTBI (8.96 cGy). Conclusion: The proposed patient comfort-oriented VMAT-TBI technique provides for a uniform dose distribution within the total body while reducing the dose to the lungs.

60 APPLIED LIFE SCIENCES↗

All order factorization for virtual Compton scattering at next-to-leading power

We discuss all-order factorization for the virtual Compton process at next-to leading power (NLP) in the Λ QCD /Q and $\sqrt{-t}$/Q expansion (twist-3), both in the double deeply-virtual case and the single-deeply-virtual case. We use the soft-collinear efective theory (SCET) as the main theoretical tool. We conclude that collinear factorization holds in the double-deeply virtual case, where both photons are far of-shell. The agreement is found with the known results for the hard matching coefcients at leading order $α^0_s$, and we can therefore connect the traditional approach with SCET. In the single-deeply-virtual case, commonly called deeply virtual Compton scattering (DVCS), the contribution of non-target collinear regions complicates the factorization. These include momentum modes collinear to the real photon and (ultra)soft interactions between the photon-collinear and target-collinear modes. However, such contributions appear only for the transversely polarized virtual photon at the NLP accuracy and in fact it is the only NLP ~ (Λ QCD /Q) 1 ~ ( $\sqrt{-t}$/Q) 1 contribution in that case. We therefore conclude that the DVCS amplitude for a longitudinally polarized virtual photon, where the leading power ~ (Λ QCD /Q) 0 ~ ($\sqrt{-t}$/Q) 0 contribution vanishes, is free of non-target collinear contributions and the collinear factorization in terms of twist-3 GPDs holds in that case as well.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Joint UAS-Balloon Activities (JUBA) Field Campaign Report

Using internal investment funds within Sandia National Laboratories’ (SNL) Division 6000, the Joint UAS-Balloon Activity (JUBA) was a collaborative exercise between SNL Organizations 6533 and 6913 (later 8863) to demonstrate simultaneous flights of tethered balloons and unmanned aerial systems (UAS) on the North Slope of Alaska. JUBA UAS and tethered balloon flights were conducted within the Restricted Airspace associated with the U.S. Department of Energy’s Atmospheric Radiation Measurement (ARM) Climate Research Facility third ARM Mobile Facility (AMF3) site at Oliktok Point, Alaska. The Restricted Airspace occupies a two-nautical-mile radius around Oliktok Point. JUBA was conducted at the Sandia Arctic Site, which is approximately 2 km east-southeast of the AMF3. JUBA activities occurred from 08/08/17 and 08/10/17. Atmospheric measurements from tethered balloons can occur for a long duration, but offer limited spatial variation. Measurements from UAS could offer increased spatial variability. To understand how balloon and UAS activities could occur together, JUBA activities included the following: Developing aviation safety plans for the simultaneous, collocated operation of tethered balloons and UAS Adapting tethered balloon-based fiber optic distributed temperature sensing (DTS) measurements to a UAS platform Creating solutions to technical challenges such as: Developing a motor system to match the fiber deployment rate with the ascent/descent rate of the UAS Evaluating methods of identifying the surface in the DTS temperature profile Correlating simultaneous balloon and UAS DTS temperature measurements Assessing the effects of a fiber optic rotary joint on the DTS temperature measurements Determining what UAS-based sensors provided the best calibration source for the DTS temperature data.

North Slope of Alaska, arctic processes, unmanned ↗

TU-F-BRF-04: Registration of 3D Transesophageal Echocardiography and X-Ray Fluoroscopy Using An Inverse Geometry X-Ray System

Purpose: To develop a method for the fusion of 3D echocardiography and Scanning-Beam Digital X-ray (SBDX) fluoroscopy to assist with catheter device and soft tissue visualization during interventional procedures. Methods: SBDX is a technology for low-dose inverse geometry x-ray fluoroscopy that performs digital tomosynthesis at multiple planes in real time. In this study, transesophageal echocardiography (TEE) images were fused with SBDX images by estimating the 3D position and orientation (the “pose”) of the TEE probe within the x-ray coordinate system and then spatially transforming the TEE image data to match this pose. An initial pose estimate was obtained through tomosynthesis-based 3D localization of points along the probe perimeter. Position and angle estimates were then iteratively refined by comparing simulated projections of a 3D probe model against SBDX x-ray images. Algorithm performance was quantified by imaging a TEE probe in different known orientations and locations within the x-ray field (0-30 degree tilt angle, up to 50 mm translation). Fused 3D TEE/SBDX imaging was demonstrated by imaging a tissue-mimicking polyvinyl alcohol cylindrical cavity as a catheter was navigated along the cavity axis. Results: Detected changes in probe tilt angle agreed with the known changes to within 1.2 degrees. For a 50 mm translation along the source-detector axis, the detected translation was 50.3 mm. Errors for in-plane translations ranged from 0.1 to 0.9 mm. In a fused 3D TEE/SBDX display, the catheter device was well visualized and coincident with the device shadow in the TEE images. The TEE images portrayed phantom boundaries that were not evident under x-ray. Conclusion: Registration of soft tissue anatomy derived from TEE imaging and device imaging from SBDX x-ray fluoroscopy is feasible. The simultaneous 3D visualization of these two modalities may be useful in interventional procedures involving the navigation of devices to soft tissue anatomy.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Prospects for true calorimetry on Kerr black holes in core-collapse supernovae and mergers

Observational evidence for black hole spin down has been found in the normalized light curves of long gamma-ray bursts in the BATSE catalog. Over the duration T{sub 90} of the burst, matter swept up by the central black hole is susceptible to nonaxisymmetries, producing gravitational radiation with a negative chirp. A time-sliced matched filtering method is introduced to capture phase coherence on intermediate time scales, {tau}, here tested by the injection of templates into experimental strain noise, h{sub n}(t). For TAMA 300, h{sub n}(f){approx_equal}10{sup -21} Hz{sup -1/2} at f=1 kHz gives a sensitivity distance for a reasonably accurate extraction of the trajectory in the time-frequency domain of about D{approx_equal}0.07-0.10 Mpc for the spin down of black holes of mass M=10-12M{sub {center_dot}} with {tau}=1 s. Extrapolation to advanced detectors implies D{approx_equal}35-50 Mpc for h{sub n}(f){approx_equal}2x10{sup -24} Hz{sup -1/2} around 1 kHz, which will open a new window to rigorous calorimetry on Kerr black holes.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Synthesis and Characterization of Nickel-Substituted Cobalt Ferrite Nanoparticles Using Sol–Gel Auto-combustion Method

In the present work, Co{sub 1−x}Ni{sub x}Fe{sub 2}O{sub 4} (x = 0.02, 0.04, and 0.06 M) is prepared by sol–gel auto-combustion method and its structural, functional, magnetic, and morphological characteristics are analyzed. The peaks corresponding to the plane observed from XRD matches with JCPDS data of CoFe{sub 2}O{sub 4} (22-1086) and NiFe{sub 2}O{sub 4} (10-0325). It is noted that the average crystallite size decreases from 31 to 27 nm when the nickel concentration increases from 0.02 to 0.06 M, indicative of the incorporation of Ni{sup 2+} ion in the cobalt ferrite lattice. FTIR analysis shows the presence of M↔O vibration at the tetrahedral and octahedral sites. Micro - Raman spectroscopy shows the stretching vibrations at 486.87 cm{sup − 1} (E{sub g}) and 696.96 cm{sup − 1} (A{sub 1g}), which are the characteristic vibrations of spinel ferrites. Magnetic studies show the variation in saturation magnetization (M{sub S} = 20.25, 9.41, 18.5 emu/g.) and coercivity (H{sub C} = 746.06, 953.03, 885.59 Oe) when the concentration of Ni{sup 2+} ion increases from 0.02 to 0.06 M. The prepared nanoparticles show a ferromagnetic nature which is attributed to the creation of an antiparallel spin and the magnetic moment created by the cation at tetrahedral and octahedral sites. The surface morphology of samples is imaged by a field emission scanning electron microscope.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Aerosol and Cloud Experiments in the Eastern North Atlantic (ACE-ENA) Winter Intensive Operational Period: Aerodynamic Particle Sizer Field Campaign Report

An aerodynamic particle sizer spectrometer (APS, model 3321 by TSI Inc., Shoreview, Minnesota) was deployed at the U.S. Department of Energy (DOE) Atmospheric Radiation Measurement (ARM) user facility Eastern North Atlantic (ENA) observatory during the second (winter) intensive operational period (IOP) of the Aerosol and Cloud Experiments in the Eastern North Atlantic (ACE-ENA) field campaign. Data were collected from January 9 through February 26, 2018, covering the second deployment of the ARM Aerial Facility (AAF) aircraft within ACE-ENA. The standard ENA instrument suite does not provide measurements of aerosol particle size distribution for diameters greater than one micron. Properties of coarse-mode (super-micron) aerosols are rarely measured, although super-micron particles can play an important role in the aerosol life cycle, affecting aerosol optical properties and cloud nuclei activity (e.g., Clarke et al. 2003). The APS was deployed to fill this gap in particle size measurements: it is capable of measuring size-resolved concentration of the aerosols in the 0.5-20 μm range (aerodynamic diameter). The APS was installed in the aerosol trailer to sample through the main stack. Special attention was given to selection of the instrument location (just below the main stack) to minimize particle losses in the connecting lines. Most atmospheric aerosols are hygroscopic, so the measurement of the aerosol size distributions should either be performed in a controlled humidity environment or accompanied by concurrent measurement of the temperature and humidity of the sample air. The latter strategy was used during this deployment: a high-precision humidity/temperature transmitter (model EE08 by E+E Elektonik GMBH, Engerwitzdorf, Germany) was mounted in the APS sampling line immediately upstream of the APS inlet. A dedicated laptop computer was used for data collection and communications. The APS was controlled with vendor-supplied software (Aerosol Instrument Manager, ver. 10.1, TSI); aerosol size distribution data were collected over a period of 55 seconds and converted to one-minute averages. Temperature and humidity analog signals were acquired via analog-to-digital converter (ADC) module (model WTAIN-M by Weeder Technologies, Fort Walton Beach, Florida) using vendor-supplied software (ModCom) with 1- sec resolution. In post-processing, the APS data were exported from TSI proprietary format into “comma-separated value” American Standard Code for Information Interchange (ASCII) files and matched with appropriately averaged temperature and humidity data. Two significant periods of missing data were caused by local power outages. Vendor-supplied software was not designed for unattended operation: it needs to be manually restarted including sensor configuration setup.

ACE-ENA, Azores, ultra-high-sensitivity aerosol sp↗

Establishing a standard calibration methodology for MOSFET detectors in computed tomography dosimetry

Purpose: The use of metal-oxide-semiconductor field-effect transistor (MOSFET) detectors for patient dosimetry has increased by {approx}25% since 2005. Despite this increase, no standard calibration methodology has been identified nor calibration uncertainty quantified for the use of MOSFET dosimetry in CT. This work compares three MOSFET calibration methodologies proposed in the literature, and additionally investigates questions relating to optimal time for signal equilibration and exposure levels for maximum calibration precision. Methods: The calibration methodologies tested were (1) free in-air (FIA) with radiographic x-ray tube, (2) FIA with stationary CT x-ray tube, and (3) within scatter phantom with rotational CT x-ray tube. Each calibration was performed at absorbed dose levels of 10, 23, and 35 mGy. Times of 0 min or 5 min were investigated for signal equilibration before or after signal read out. Results: Calibration precision was measured to be better than 5%-7%, 3%-5%, and 2%-4% for the 10, 23, and 35 mGy respective dose levels, and independent of calibration methodology. No correlation was demonstrated for precision and signal equilibration time when allowing 5 min before or after signal read out. Differences in average calibration coefficients were demonstrated between the FIA with CT calibration methodology 26.7 {+-} 1.1 mV cGy{sup -1} versus the CT scatter phantom 29.2 {+-} 1.0 mV cGy{sup -1} and FIA with x-ray 29.9 {+-} 1.1 mV cGy{sup -1} methodologies. A decrease in MOSFET sensitivity was seen at an average change in read out voltage of {approx}3000 mV. Conclusions: The best measured calibration precision was obtained by exposing the MOSFET detectors to 23 mGy. No signal equilibration time is necessary to improve calibration precision. A significant difference between calibration outcomes was demonstrated for FIA with CT compared to the other two methodologies. If the FIA with a CT calibration methodology was used to create calibration coefficients for the eventual use for phantom dosimetry, a measurement error {approx}12% will be reflected in the dosimetry results. The calibration process must emulate the eventual CT dosimetry process by matching or excluding scatter when calibrating the MOSFETs. Finally, the authors recommend that the MOSFETs are energy calibrated approximately every 2500-3000 mV.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Quantitative comparison of noise texture across CT scanners from different manufacturers

Purpose: To quantitatively compare noise texture across computed tomography (CT) scanners from different manufacturers using the noise power spectrum (NPS). Methods: The American College of Radiology CT accreditation phantom (Gammex 464, Gammex, Inc., Middleton, WI) was imaged on two scanners: Discovery CT 750HD (GE Healthcare, Waukesha, WI), and SOMATOM Definition Flash (Siemens Healthcare, Germany), using a consistent acquisition protocol (120 kVp, 0.625/0.6 mm slice thickness, 250 mAs, and 22 cm field of view). Images were reconstructed using filtered backprojection and a wide selection of reconstruction kernels. For each image set, the 2D NPS were estimated from the uniform section of the phantom. The 2D spectra were normalized by their integral value, radially averaged, and filtered by the human visual response function. A systematic kernel-by-kernel comparison across manufacturers was performed by computing the root mean square difference (RMSD) and the peak frequency difference (PFD) between the NPS from different kernels. GE and Siemens kernels were compared and kernel pairs that minimized the RMSD and |PFD| were identified. Results: The RMSD (|PFD|) values between the NPS of GE and Siemens kernels varied from 0.01 mm{sup 2} (0.002 mm{sup -1}) to 0.29 mm{sup 2} (0.74 mm{sup -1}). The GE kernels 'Soft,''Standard,''Chest,' and 'Lung' closely matched the Siemens kernels 'B35f,''B43f,''B41f,' and 'B80f' (RMSD < 0.05 mm{sup 2}, |PFD| < 0.02 mm{sup -1}, respectively). The GE 'Bone,''Bone+,' and 'Edge' kernels all matched most closely with Siemens 'B75f' kernel but with sizeable RMSD and |PFD| values up to 0.18 mm{sup 2} and 0.41 mm{sup -1}, respectively. These sizeable RMSD and |PFD| values corresponded to visually perceivable differences in the noise texture of the images. Conclusions: It is possible to use the NPS to quantitatively compare noise texture across CT systems. The degree to which similar texture across scanners could be achieved varies and is limited by the kernels available on each scanner.

60 APPLIED LIFE SCIENCES↗

THE CIRCUMGALACTIC MEDIUM OF MASSIVE GALAXIES AT z {approx} 3: A TEST FOR STELLAR FEEDBACK, GALACTIC OUTFLOWS, AND COLD STREAMS

We present new results on the kinematics, thermal and ionization state, and spatial distribution of metal-enriched gas in the circumgalactic medium (CGM) of massive galaxies at redshift {approx}3, using the Eris suite of cosmological hydrodynamic ''zoom-in'' simulations. The reference run adopts a blastwave scheme for supernova feedback that produces large-scale galactic outflows, a star formation recipe based on a high gas density threshold, metal-dependent radiative cooling, and a model for the diffusion of metals and thermal energy. The effect of the local UV radiation field is added in post-processing. The CGM (defined as all gas at R > 0.2 R{sub vir} = 10 kpc, where R{sub vir} is the virial radius) contains multiple phases having a wide range of physical conditions, with more than half of its heavy elements locked in a warm-hot component at T > 10{sup 5} K. Synthetic spectra, generated by drawing sightlines through the CGM, produce interstellar absorption-line strengths of Ly{alpha}, C II, C IV, Si II, and Si IV as a function of the galactocentric impact parameter (scaled to the virial radius) that are in broad agreement with those observed at high redshift by Steidel et al. The covering factor of absorbing material declines less rapidly with impact parameter for Ly{alpha} and C IV compared to C II, Si IV, and Si II, with Ly{alpha} remaining strong (W{sub Ly{alpha}} > 300 mA) to {approx}> 5 R{sub vir} = 250 kpc. Only about one third of all the gas within R{sub vir} is outflowing. The fraction of sightlines within one virial radius that intercept optically thick, N{sub H{sub I}}>10{sup 17.2} cm{sup -2} material is 27%, in agreement with recent observations by Rudie et al. Such optically thick absorption is shown to trace inflowing ''cold'' streams that penetrate deep inside the virial radius. The streams, enriched to metallicities above 0.01 solar by previous episodes of star formation in the main host and in nearby dwarfs, are the origin of strong (N{sub C{sub II}}>10{sup 13} cm{sup -2}) C II absorption with a covering factor of 22% within R{sub vir} and 10% within 2 R{sub vir}. Galactic outflows do not cause any substantial suppression of the cold accretion mode. The central galaxy is surrounded by a large O VI halo, with a typical column density N{sub O{sub VI}} {approx}> 10{sup 14} cm{sup -2} and a near unity covering factor maintained all the way out to 150 kpc. This matches the trends recently observed in star-forming galaxies at low redshift by Tumlinson et al. Our zoom-in simulations of this single system appear then to reproduce quantitatively the complex baryonic processes that determine the exchange of matter, energy, and metals between galaxies and their surroundings.

79 ASTRONOMY AND ASTROPHYSICS↗

Stability of polytropes

This paper is an investigation of the stability of some ideal stars. It is intended as a study in general relativity, with emphasis on the coupling to matter, aimed at a better understanding of strong gravitational fields and 'black holes'. This contrasts with the usual attitude in astrophysics, where Einstein's equations are invoked as a refinement of classical thermodynamics and Newtonian gravity. Our work is based on action principles for systems of metric and matter fields, well-defined relativistic field models that we hope may represent plausible types of matter. The thermodynamic content must be extracted from the theory itself. When the flow of matter is irrotational, and described by a scalar density, we are led to differential equations that differ little from those of Tolman, but they admit a conserved current, and stronger boundary conditions that affect the matching of the interior solution to an external metric and imply a relation of mass and radius. We propose a complete revision of the treatment of boundary conditions. An ideal star in our terminology has spherical symmetry and an isentropic equation of state, p=a{rho}{sup {gamma}}, a and {gamma} piecewise constant. In our first work it was assumed that the density vanished beyond a finite distance from the origin and that the metric is to be matched at the boundary to an exterior Schwartzchild metric. But it is difficult to decide what the boundary conditions should be and we are consequently skeptical of the concept of a fixed boundary. We investigate the double polytrope, characterized by a polytropic index n{<=}3, in the bulk of the star and a value larger than five in an outer atmosphere that extends to infinity. It has no fixed boundary but a region of critical density where the polytropic index changes from a value that is appropriate for the bulk of the star to a value that provides a crude model for the atmosphere. The boundary conditions are now natural and unambiguous. The existence of a relation between mass and radius is confirmed, as well as an upper limit on the mass. The principal conclusion is that all the static configurations are stable. There is a solution that fits the Sun. The masses of white dwarfs respect the Chandrasekhar limit. The application to neutron stars has surprising aspects.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

SU-F-T-434: Development of a Fan-Beam Optical Scanner Using CMOS Array for Small Field Dosimetry

Purpose: To design and construct a second generation optical computed tomography (OCT) system using a fan-beam with a CMOS array detector for the 3D dosimetry with polymer gel and radiochromic solid dosimeters. The system was specifically designed for the small field dosimetry. Methods: The optical scanner used a fan-beam laser, which was produced from a collimated red laser beam (λ=620 nm) with a 15-degree laser-line generating lens. The fan-beam was sent through an index-matching bath which holds the sample stage and a sample. The emerging laser light was detected with a 2.54 cm-long CMOS array detector (512 elements). The sample stage rotated through the full 360 degree projection angles at 0.9-degree increments. Each projection was normalized to the unirradiated sample at the projection angle to correct for imperfections in the dosimeter. A larger sample could be scanned by using a motorized mirror and linearly translating the CMOS detector. The height of the sample stage was varied for a full 3D scanning. The image acquisition and motor motion was controlled by a computer. The 3D image reconstruction was accomplished by a fan-beam reconstruction algorithm. All the software was developed inhouse with MATLAB. Results: The scanner was used on both PRESAGE and PAGAT gel dosimeters. Irreconcilable refraction errors were seen with PAGAT because the fan beam laser line refracted away from the detector when the field was highly varying in 3D. With PRESAGE, this type of error was not seen. Conclusion: We could acquire tomographic images of dose distributions by the new OCT system with both polymer gel and radiochromic solid dosimeters. Preliminary results showed that the system was more suited for radiochromic solid dosimeters since the radiochromic dosimeters exhibited minimal refraction and scattering errors. We are currently working on improving the image quality by thorough characterization of the OCT system.

60 APPLIED LIFE SCIENCES↗

The Principle of Maximum Conformality

A key problem in making precise perturbative QCD predictions is the uncertainty in determining the renormalization scale of the running coupling {alpha}{sub s}({mu}{sup 2}). It is common practice to guess a physical scale {mu} = Q which is of order of a typical momentum transfer Q in the process, and then vary the scale over a range Q/2 and 2Q. This procedure is clearly problematic since the resulting fixed-order pQCD prediction will depend on the renormalization scheme, and it can even predict negative QCD cross sections at next-to-leading-order. Other heuristic methods to set the renormalization scale, such as the 'principle of minimal sensitivity', give unphysical results for jet physics, sum physics into the running coupling not associated with renormalization, and violate the transitivity property of the renormalization group. Such scale-setting methods also give incorrect results when applied to Abelian QED. Note that the factorization scale in QCD is introduced to match nonperturbative and perturbative aspects of the parton distributions in hadrons; it is present even in conformal theory and thus is a completely separate issue from renormalization scale setting. The PMC provides a consistent method for determining the renormalization scale in pQCD. The PMC scale-fixed prediction is independent of the choice of renormalization scheme, a key requirement of renormalization group invariance. The results avoid renormalon resummation and agree with QED scale-setting in the Abelian limit. The PMC global scale can be derived efficiently at NLO from basic properties of the PQCD cross section. The elimination of the renormalization scheme ambiguity using the PMC will not only increases the precision of QCD tests, but it will also increase the sensitivity of colliders to new physics beyond the Standard Model.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Dilepton radiation by vector mesons and off-shell partons in the hot and dense medium

According to the dynamical quasiparticle model (DQPM) - matched to reproduce lattice QCD results in thermodynamic limit, - the constituents of the strongly interacting quark-gluon plasma (sQGP) are massive and off-shell quasi-particles (quarks and gluons) with broad spectral functions. In order to address the electromagnetic radiation of the sQGP, we derive off-shell cross sections of qq-bar{yields}{gamma}*, qq-bar{yields}{gamma}*+g and qg{yields}{gamma}*q(q-barg{yields}{gamma}*q-bar) reactions taking into account the effective propagators for quarks and gluons from the DQPM. Dilepton production in In+In collisions at 158 AGeV is studied by implementing these processes into the parton-hadron-string dynamics (PHSD) transport approach. The microscopic PHSD transport approach describes the full evolution of the heavy-ion collision: from the dynamics of quasi-particles in the sQGP phase (when the local energy density is above {approx}1 GeV/fm{sup 3}) through hadronization and to the following hadron interactions and off-shell propagation after the hadronization. A comparison to the data of the NA60 Collaboration shows that the low mass dilepton spectra are well described by including a collisional broadening of vector mesons, while the spectra in the intermediate mass range are dominated by off-shell quark-antiquark annihilation, quark Bremsstrahlung and gluon-Compton scattering in the nonperturbative QGP. In particular, the observed softening of the m{sub T} spectra at intermediate masses (1 GeV {<=} M {<=} 3 GeV) is approximately reproduced.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗