Search NASA⌕ Search

SEARCH · Search NASA

Results for “network security”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 721 records · Page 40

GridAgents DER Testing (CRADA Final Report)

The project objectives are to perform research, development, and pilot-scale testing of advanced, next-generation distribution operational strategies using ConEdison's 3G: Distribution System of the Future and associated infrastructure for the real-world Test Bed (demonstration network) combined with the Infotility GridAgents: Secure Agent Framework for Energy as the software platform foradvanced operational strategies development. The objective is to accelerate high-payoff technologies that, because of their risk, are unlikely to be developed in a timely manner without a partnership between industry and the Federal government. NREL will be responsible for the evaluation of equipment design and control methods for DER integration and testing of prototype DER technologies andcontrol equipment at the NREL test facility.

25 ENERGY STORAGE↗

Hybrid methods for cybersecurity analysis :

Early 2010 saw a signi cant change in adversarial techniques aimed at network intrusion: a shift from malware delivered via email attachments toward the use of hidden, embedded hyperlinks to initiate sequences of downloads and interactions with web sites and network servers containing malicious software. Enterprise security groups were well poised and experienced in defending the former attacks, but the new types of attacks were larger in number, more challenging to detect, dynamic in nature, and required the development of new technologies and analytic capabilities. The Hybrid LDRD project was aimed at delivering new capabilities in large-scale data modeling and analysis to enterprise security operators and analysts and understanding the challenges of detection and prevention of emerging cybersecurity threats. Leveraging previous LDRD research e orts and capabilities in large-scale relational data analysis, large-scale discrete data analysis and visualization, and streaming data analysis, new modeling and analysis capabilities were quickly brought to bear on the problems in email phishing and spear phishing attacks in the Sandia enterprise security operational groups at the onset of the Hybrid project. As part of this project, a software development and deployment framework was created within the security analyst work ow tool sets to facilitate the delivery and testing of new capabilities as they became available, and machine learning algorithms were developed to address the challenge of dynamic threats. Furthermore, researchers from the Hybrid project were embedded in the security analyst groups for almost a full year, engaged in daily operational activities and routines, creating an atmosphere of trust and collaboration between the researchers and security personnel. The Hybrid project has altered the way that research ideas can be incorporated into the production environments of Sandias enterprise security groups, reducing time to deployment from months and years to hours and days for the application of new modeling and analysis capabilities to emerging threats. The development and deployment framework has been generalized into the Hybrid Framework and incor- porated into several LDRD, WFO, and DOE/CSL projects and proposals. And most importantly, the Hybrid project has provided Sandia security analysts with new, scalable, extensible analytic capabilities that have resulted in alerts not detectable using their previous work ow tool sets.

Dunlavy, Daniel M.↗

Long Island Smart Energy Corridor

The Long Island Power Authority (LIPA) has teamed with Stony Brook University (Stony Brook or SBU) and Farmingdale State College (Farmingdale or FSC), two branches of the State University of New York (SUNY), to create a “Smart Energy Corridor.” The project, located along the Route 110 business corridor on Long Island, New York, demonstrated the integration of a suite of Smart Grid technologies from substations to end-use loads. The Smart Energy Corridor Project included the following key features: -TECHNOLOGY: Demonstrated a full range of smart energy technologies, including substations and distribution feeder automation, fiber and radio communications backbone, advanced metering infrastructure (AM”), meter data management (MDM) system (which LIPA implemented outside of this project), field tools automation, customer-level energy management including automated energy management systems, and integration with distributed generation and plug-in hybrid electric vehicles. -MARKETING: A rigorous market test that identified customer response to an alternative time-of-use pricing plan and varying levels of information and analytical support. -CYBER SECURITY: Tested cyber security vulnerabilities in Smart Grid hardware, network, and application layers. Developed recommendations for policies, procedures, and technical controls to prevent or foil cyber-attacks and to harden the Smart Grid infrastructure. -RELIABILITY: Leveraged new Smart Grid-enabled data to increase system efficiency and reliability. Developed enhanced load forecasting, phase balancing, and voltage control techniques designed to work hand-in-hand with the Smart Grid technologies. -OUTREACH: Implemented public outreach and educational initiatives that were linked directly to the demonstration of Smart Grid technologies, tools, techniques, and system configurations. This included creation of full-scale operating models demonstrating application of Smart Grid technologies in business and residential settings. Farmingdale State College held three international conferences on energy and sustainability and Smart Grid related technologies and policies. These conferences, in addition to public seminars increased understanding and acceptance of Smart Grid transformation by the general public, business, industry, and municipalities in the Long Island and greater New York region. - JOB CREATION: Provided training for the Smart Grid and clean energy jobs of the future at both Farmingdale and Stony Brook. Stony Brook focused its “Cradle to Fortune 500” suite of economic development resources on the opportunities emerging from the project, helping to create new technologies, new businesses, and new jobs. To achieve these features, LIPA and its sub-recipients, FSC and SBU, each have separate but complementary objectives. At LIPA, the Smart Energy Corridor (1) meant validating Smart Grid technologies; (2) quantifying Smart Grid costs and benefits; and (3) providing insights into how Smart Grid applications can be better implemented, readily adapted, and replicated in individual homes and businesses. LIPA installed 2,550 AMI meters (exceeding the 500 AMI meters in the original plan), created three “smart” substations serving the Corridor, and installed additional distribution automation elements including two-way communications and digital controls over various feeders and capacitor banks. It gathered and analyzed customer behavior information on how they responded to a new “smart” TOU rate and to various levels of information and analytical tools.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Inferring Netflow Data

Netflow data is a specific format for looking at network traffic. With this format, many security tests are easy to run. Cloud Service Providers produce logs that do not contain all of the content that Netflow data contains. There is a possibility that the fields that are in Netflow data but absent in Cloud Service Provider logs can be inferred from the fields that are present in the Cloud Service Provider logs. By inferring the missing data fields, the same test that can be run with Netflow data would be possible to run on the logs produced by Cloud Service Providers. Cloud Service Providers include Amazon Web Services and Box.com. There are multiple different types of Cloud Services, and each provider handles them differently and produces different logs. There are IaaS (meaning infrastructure as a service), Saas (meaning software as a service), and Paas (meaning platform as a service). Each provides a different use for the user.

97 MATHEMATICS AND COMPUTING↗

Distributed Acoustic Sensing (DAS) on Opportunistic Networks_ A Feasibility Study Utilizing Fiber Optic Infrastructure at NEON Sites for DAS

This study demonstrates the feasibility of using Distributed Acoustic Sensing (DAS) on the opportunistic optical fiber infrastructure presented by NEON (National Ecological Observatory Network) sites. The test took place at the NEON Terrestrial Site designated D10 CPER. Unlit portions of the local fiber network were successfully spliced together and optimized for length and a Silixa iDAS sensor was installed. The resulting array (composed of 12 spliced fiber runs) totaled 875m in length. Over a period of 2 weeks, we gathered a high spatial and temporal resolution data set to characterize discernable signals and understand background noise. The data set was reviewed to extract wave signatures of identifiable origin, both anthropogenic and otherwise. Continent wide distribution of these sites makes them an interesting candidate for DAS and identifying measurable signal sources informs future DAS application on opportunistic fiber networks. These observations validate the utility of both the NEON and similarly small fiber networks (<1km) for geoscience, environmental, and security DAS applications and indicate possibilities for further inquiry in methods for DAS data collection and analysis.

42 ENGINEERING↗

Distributed Energy Resource Cybersecurity Standards Development [Final Report]

Currently, the solar industry is operating with little application-specific guidance on how to protect and defend their systems from cyberattacks. This 3-year Department of Energy (DOE) Solar Energy Technologies Office-funded project helped advance the distributed energy resource (DER) cybersecurity state-of-the-art by (a) bolstering industry awareness of cybersecurity concepts, risks, and solutions through a webinar series and (b) developing recommendations for DER cybersecurity standards to improve the security performance of DER products and networks. Drafting DER standards is a lengthy, consensus-based process requiring effective leadership and stakeholder participation. This project was designed to reduce standard and guide writing times by creating well-researched recommendations that could act as a starting place for national and international standards development organizations. Working within the SunSpec/Sandia DER Cybersecurity Workgroup, the team produced guidance for DER cybersecurity certification, communication protocol standards, network architecture s, access control, and patching. The team also led subgroups within the IEEE P 1547.3 Guide for Cybersecurity of Distributed Energy Resources Interconnected with Electric Power Systems committee and pushed a draft to ballot in October 2021.

14 SOLAR ENERGY↗

CO2-driven Enhanced Oil Recovery as a Stepping Stone to What?

This paper draws heavily on the authors’ previously published research to explore the extent to which near term carbon dioxide-driven enhanced oil recovery (CO2-EOR) can be “a stepping stone to a long term sequestration program of a scale to be material in climate change risk mitigation.” The paper examines the historical evolution of CO2-EOR in the United States and concludes that estimates of the cost of CO2-EOR production or the extent of CO2 pipeline networks based upon this energy security-driven promotion of CO2-EOR do not provide a robust platform for spurring the commercial deployment of carbon dioxide capture and storage technologies (CCS) as a means of reducing greenhouse gas emissions. The paper notes that the evolving regulatory framework for CCS makes a clear distinction between CO2-EOR and CCS and the authors examine arguments in the technical literature about the ability for CO2-EOR to generate offsetting revenue to accelerate the commercial deployment of CCS systems in the electric power and industrial sectors of the economy. The authors conclude that the past 35 years of CO2-EOR in the U.S. have been important for boosting domestic oil production and delivering proven system components for future CCS systems. However, though there is no reason to suggest that CO2-EOR will cease to deliver these benefits, there is also little to suggest that CO2-EOR is a necessary or significantly beneficial step towards the commercial deployment of CCS as a means of addressing climate change.

02 PETROLEUM↗

Emergency Operations Center at Johnson Space Center

In June 1966, at the start of the Gulf Coast hurricane season, the Johnson Space Center (JSC) celebrated the opening of its new 4,000-square foot, state-of-the-art Emergency Operations Center (EOC). The new EOC has been upgraded and enhanced to support a wide spectrum of emergencies affecting JSC and neighboring communities. One of the main features of the EOC is its premier computerized dispatch center. The new system unites many of JSC's critical emergency functions into one integrated network. It automatically monitors fire alarms, security entrances, and external cameras. It contains the JSC inventory of hazardous materials, by building and room, and can call up Material Safety Data Sheets for most of the generic hazardous materials used on-site. The EOC is available for community use during area emergencies such as hurricanes and is a welcome addition to the Clear Lake/Galveston Bay Area communities' emergency response resources.

Caylor, Gary C.↗

Automated Euler and Navier-Stokes Database Generation for a Glide-Back Booster

The past two decades have seen a sustained increase in the use of high fidelity Computational Fluid Dynamics (CFD) in basic research, aircraft design, and the analysis of post-design issues. As the fidelity of a CFD method increases, the number of cases that can be readily and affordably computed greatly diminishes. However, computer speeds now exceed 2 GHz, hundreds of processors are currently available and more affordable, and advances in parallel CFD algorithms scale more readily with large numbers of processors. All of these factors make it feasible to compute thousands of high fidelity cases. However, there still remains the overwhelming task of monitoring the solution process. This paper presents an approach to automate the CFD solution process. A new software tool, AeroDB, is used to compute thousands of Euler and Navier-Stokes solutions for a 2nd generation glide-back booster in one week. The solution process exploits a common job-submission grid environment, the NASA Information Power Grid (IPG), using 13 computers located at 4 different geographical sites. Process automation and web-based access to a MySql database greatly reduces the user workload, removing much of the tedium and tendency for user input errors. The AeroDB framework is shown. The user submits/deletes jobs, monitors AeroDB's progress, and retrieves data and plots via a web portal. Once a job is in the database, a job launcher uses an IPG resource broker to decide which computers are best suited to run the job. Job/code requirements, the number of CPUs free on a remote system, and queue lengths are some of the parameters the broker takes into account. The Globus software provides secure services for user authentication, remote shell execution, and secure file transfers over an open network. AeroDB automatically decides when a job is completed. Currently, the Cart3D unstructured flow solver is used for the Euler equations, and the Overflow structured overset flow solver is used for the Navier-Stokes equations. Other codes can be readily included into the AeroDB framework.

Chaderjian, Neal M.↗

Smashing the Stovepipe: Leveraging the GMSEC Open Architecture and Advanced IT Automation to Rapidly Prototype, Develop and Deploy Next-Generation Multi-Mission Ground Systems

Satellite/Payload Ground Systems - Typically highly-customized to a specific mission's use cases - Utilize hundreds (or thousands!) of specialized point-to-point interfaces for data flows / file transfers Documentation and tracking of these complex interfaces requires extensive time to develop and extremely high staffing costs Implementation and testing of these interfaces are even more cost-prohibitive, and documentation often lags behind implementation resulting in inconsistencies down the road With expanding threat vectors, IT Security, Information Assurance and Operational Security have become key Ground System architecture drivers New Federal security-related directives are generated on a daily basis, imposing new requirements on current / existing ground systems - These mandated activities and data calls typically carry little or no additional funding for implementation As a result, Ground System Sustaining Engineering groups and Information Technology staff continually struggle to keep up with the rolling tide of security Advancing security concerns and shrinking budgets are pushing these large stove-piped ground systems to begin sharing resources - I.e. Operational / SysAdmin staff, IT security baselines, architecture decisions or even networks / hosting infrastructure Refactoring these existing ground systems into multi-mission assets proves extremely challenging due to what is typically very tight coupling between legacy components As a result, many "Multi-Mission" ops. environments end up simply sharing compute resources and networks due to the difficulty of refactoring into true multi-mission systems Utilizing continuous integration / rapid system deployment technologies in conjunction with an open architecture messaging approach allows System Engineers and Architects to worry less about the low-level details of interfaces between components and configuration of systems GMSEC messaging is inherently designed to support multi-mission requirements, and allows components to aggregate data across multiple homogeneous or heterogeneous satellites or payloads - The highly-successful Goddard Science and Planetary Operations Control Center (SPOCC) utilizes GMSEC as the hub for it's automation and situational awareness capability Shifts focus towards getting GS to a final configuration-managed baseline, as well as multi-mission / big-picture capabilities that help increase situational awareness, promote cross-mission sharing and establish enhanced fleet management capabilities across all levels of the enterprise.

GMSEC↗

Integration Test and Evaluation (IT&E) Flight Test Series 6 Live Virtual Constructive - Distributed Environment (LVC-DE) Test Report

The goals of the Unmanned Aircraft Systems (UAS) Integration in the National Airspace System (NAS) (also UAS-NAS) Project are to reduce the barriers for UAS access and its integration into the NAS. The UAS-NAS project and industry stakeholders conducted a series of flight tests integrating technologies from the Modeling & Simulation (M&S), Human Systems Integration (HSI), and Communication and Control (C2), and Integration, Test & Evaluation (IT&E) research areas. The last of the flight test series, Flight Test Series 6 (FT6) was conducted in late 2019 and focused on evaluating the interaction of the airborne non-cooperative surveillance system and the Detect and Avoid (DAA) technology. The DAA system generated conflict alert and guidance for pilots using a Research Ground Control System (RGCS) to avoid intruder aircraft. The conflict alerting and guidance information was presented on the RGCS’s display using symbology developed by the human factors team. The objective of FT6 was to investigate the interoperability of Low Size, Weight, and Power (Low SWaP) sensors with the DAA alerting, guidance, and display requirements. To support this goal, the distributed test environments (DTE) were developed at Ames Research Center (ARC) and Armstrong Flight Research Center (AFRC) and securely linked over a Virtual Private Network (VPN). These environments took advantage of existing Live Virtual Constructive (LVC) technologies to support research observation at both Centers with the insertion of live UAS and manned intruder aircraft into a simulated NAS environment with Air Traffic Control (ATC) and constructive manned aircraft. The experiment was distributed between AFRC flight operations and research facilities and the Distributed Simulation Research Laboratory (DSRL) and Software Development Laboratory (SDL) in building N243 at ARC. The Air Traffic Controller and pseudo pilots operated from the DSRL and SDL, respectively, using the Multi-Aircraft Control System (MACS). The test subject and researchers operated from the Research Ground Control Station (RGCS) at AFRC using the Vigilant Spirit Control Station (VSCS) and associated DAA software and displays. Flight Operation for the unmanned aircraft (UA) and manned intruder traffic was conducted at AFRC. Virtual traffic was managed by ARC. Voice distribution was accomplished using a combination of disparate communication systems at ARC and AFRC. The purpose of this document is to record the development, design, and execution of activities in support of the FT6 efforts from the perspective of the ARC IT&E team. Furthermore, the Armstrong IT&E team has published a thorough FT6 Test Report, with emphasis on flight test support, facilities and vehicle development; this report complements the Armstrong report. Analysis of collected FT6 data will be conducted and reported by the M&S and HSI teams and will be published in separate reports.

UAS-NAS↗

A Robust Infrastructure Design for Gas Centrifuge Enrichment Plant Unattended Online Enrichment Monitoring

An online enrichment monitor (OLEM) is being developed to continuously measure the relative isotopic composition of UF6 in the unit header pipes of a gas centrifuge enrichment plant (GCEP). From a safeguards perspective, OLEM will provide early detection of a facility being misused for production of highly enriched uranium. OLEM may also reduce the number of samples collected for destructive assay and if coupled with load cell monitoring can provide isotope mass balance verification. The OLEM design includes power and network connections for continuous monitoring of the UF6 enrichment and state of health of the instrument. Monitoring the enrichment on all header pipes at a typical GCEP could require OLEM detectors on each of the product, tails, and feed header pipes. If there are eight process units, up to 24 detectors may be required at a modern GCEP. Distant locations, harsh industrial environments, and safeguards continuity of knowledge requirements all place certain demands on the network robustness and power reliability. This paper describes the infrastructure and architecture of an OLEM system based on OLEM collection nodes on the unit header pipes and power and network support nodes for groupings of the collection nodes. A redundant, self-healing communications network, distributed backup power, and a secure communications methodology. Two candidate technologies being considered for secure communications are the Object Linking and Embedding for Process Control Unified Architecture cross-platform, service-oriented architecture model for process control communications and the emerging IAEA Real-time And INtegrated STream-Oriented Remote Monitoring (RAINSTORM) framework to provide the common secure communication infrastructure for remote, unattended monitoring systems. The proposed infrastructure design offers modular, commercial components, plug-and-play extensibility for GCEP deployments, and is intended to meet the guidelines and requirements for unattended and remotely monitored safeguards systems.

On Line Enrichment Monitor GCEP↗

SOPHIA

Network traffic monitoring software.

97 MATHEMATICS AND COMPUTING↗

Software Defined Cyber-Physical Testbed for Analysis of Automated Cyber Responses for Power System Security

As the power grid becomes more interconnected the attack surface increases and determining the causes of anomalies becomes more complex. Automated responses are a mechanism which can provide resilience in a power system by responding to anomalies. An automated response system can make intelligent decisions when paired with an automated health assessment system which includes a human in the loop for making critical decisions. Effective responses can be determined by developing a matrix which considers the likely impacts on resilience if a response is taken. A testbed assists to analyze these responses and determine their effects on system resilience.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Design Choices in Anomaly Detection for Industrial Control Systems: Insights from Gas Pipeline Data

Industrial control systems (ICS) remain vulnerable to increasingly sophisticated cyberattacks, yet evaluating anomaly detection models in these environments is challenging due to temporal dependencies, missing-not-at-random patterns, and extremely imbalanced datasets. These factors make common practices—especially random data splits and naïve imputation—prone to severe temporal leakage, which can inflate reported performance and obscure real-world limitations. In this work, we systematically examine classical machine learning models, temporal deep learning architecture, and tensor-decomposition–based methods on a gas-pipeline dataset using a fully temporally separated evaluation pipeline designed to mimic realistic deployment conditions. Our findings show that proper temporal handling and MNAR-aware preprocessing significantly alter the relative performance of popular anomaly-detection methods, providing practical guidance for designing reliable, leakage-resistant ICS intrusion-detection systems.

97 MATHEMATICS AND COMPUTING↗