Search NASA⌕ Search

SEARCH · Search NASA

Results for “nuclear pulse processing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 721 records · Page 40

New measurements of low-energy resonances in the Ne 22 ( p , γ ) Na 23 reaction

The Ne 22 ( p , γ ) Na 23 reaction is one of the most uncertain reactions in the NeNa cycle and plays a crucial role in the creation of Na 23 , the only stable Na isotope. Uncertainties in the low-energy rates of this and other reactions in the NeNa cycle lead to ambiguities in the nucleosynthesis predicted from models of thermally pulsing asymptotic giant branch (AGB) stars. This in turn complicates the interpretation of anomalous Na-O trends in globular cluster evolutionary scenarios. Prior studies of the Ne 22 ( p , γ ) Na 23 , Ne 22 ( He 3 , d ) Na 23 , and C 12 ( C 12 , p ) Na 23 reactions disagree on the strengths, spins, and parities of low-energy resonances in Na 23 and the direct-capture Ne 22 ( p , γ ) Na 23 reaction rate contains large uncertainties as well. Here, we present new measurements of resonances at E r c.m. = 417 , 178, and 151 keV and of the direct-capture process in the Ne 22 ( p , γ ) Na 23 reaction. The resulting total Ne 22 ( p , γ ) Na 23 rate is approximately a factor of 20 higher than the rate listed in a recent compilation at temperatures relevant to hot-bottom burning in AGB stars. Although our rate is close to that derived from a recent Ne 22 ( p , γ ) Na 23 measurement by Cavanna et al. in 2015, we find that this large rate increase results in only a modest 18% increase in the Na 23 abundance predicted from a 5 M ⊙ thermally pulsing AGB star model from Ventura and D'Antona (2005). The estimated astrophysical impact of this rate increase is in marked contrast to the factor of ~ 3 increase in Na 23 abundance predicted by Cavanna et al. and is attributed to the interplay between the Na 23 ( p , α ) Ne 20 and Ne 20 ( p , γ ) Na 21 reactions, both of which remain fairly uncertain at the relevant temperature range.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

In situ laser processing in a scanning electron microscope

Laser delivery probes using multimode fiber optic delivery and bulk focusing optics have been constructed and used for performing materials processing experiments within scanning electron microscope/focused ion beam instruments. Controlling the current driving a 915-nm semiconductor diode laser module enables continuous or pulsed operation down to sub-microsecond durations, and with spot sizes on the order of 50 {mu}m diameter, achieving irradiances at a sample surface exceeding 1 MW/cm{sup 2}. Localized laser heating has been used to demonstrate laser chemical vapor deposition of Pt, surface melting of silicon, enhanced purity, and resistivity via laser annealing of Au deposits formed by electron beam induced deposition, and in situ secondary electron imaging of laser induced dewetting of Au metal films on SiO{sub x}.

36 MATERIALS SCIENCE↗

Thermal neutron detection using alkali halide scintillators with Li-6 and pulse shape discrimination

An ideal 3 He detector replacement for the near- to medium-term future will use materials that are easy to produce and well understood, while maintaining thermal neutron detection efficiency and gamma rejection close to the 3 He standard. Toward this end, we investigated the use of standard alkali halide scintillators interfaced with 6 Li and read out with photomultiplier tubes (PMTs). Thermal neutrons are captured on 6 Li with high efficiency, emitting high-energy and triton ( 3 H) reaction products. These particles deposit energy in the scintillator, providing a thermal neutron signal; discrimination against gamma interactions is possible via pulse shape discrimination (PSD), since heavy particles produce faster pulses in alkali halide crystals. We constructed and tested two classes of detectors based on this concept. In one case 6 Li is used as a dopant in polycrystalline NaI; in the other case a thin Li foil is used as a conversion layer. In the configurations studied here, these systems are sensitive to both gamma and neutron radiation, with discrimination between the two and good energy resolution for gamma spectroscopy. We present results from our investigations, including measurements of the neutron efficiency and gamma rejection for the two detector types. We also show a comparison with Cs 2 LiYCl 6 :Ce (CLYC), which is emerging as the standard scintillator for simultaneous gamma and thermal neutron detection, and also allows PSD. We conclude that 6 Li foil with CsI scintillating crystals has near-term promise as a thermal neutron detector in applications previously dominated by 3 He detectors. The other approach, 6 Li-doped alkali halides, has some potential, but require more work to understand material properties and improve fabrication processes.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Pure Optical Dephasing Dynamics in Semiconducting Single-Walled Carbon Nanotubes

We report a detailed study of ultrafast exciton dephasing processes in semiconducting single-walled carbon nanotubes (SWNTs) employing a sample highly enriched in a single tube species, the (6,5) tube. Systematic measurements of femtosecond pump-probe, two-pulse photon echo and three-pulse photon echo peak shift over a broad range of excitation intensities and lattice temperature (from 4.4 to 292 K) enable us to quantify the timescales of pure optical dephasing (T ∗ 2 ), along with exciton-exciton and exciton-phonon scattering, environmental effects as well as spectral diffusion. While the exciton dephasing time (T2 ) increases from 205 fs at room temperature to 320 fs at 70 K, we found that further decrease of the lattice temperature leads to a shortening of the T2 times. This complex temperature dependence was found to arise from an enhanced relaxation of exciton population at lattice temperatures below 80 K. By quantitatively accounting the contribution from the population relaxation, the corresponding pure optical dephasing times increase monotonically from 225 fs at room temperature to 508 fs at 4.4 K. We further found that below 180 K, the inverse of the pure dephasing time (1/T ∗ 2 ) scales linearly with temperature with a slope of 6.7 ±0.6 μeV/K, which suggests dephasing arising from one-phonon scattering (i.e. acoustic phonons). In view ofthe large dynamic disorder of the surrounding environment, the origin of the long room temperature pure dephasing time is proposed to result from reduced strength of exciton-phonon coupling by motional narrowing over nuclear fluctuations. This consideration further suggests the occurrence of remarkable initial exciton delocalization, and makes nanotubes ideal to study many-body effects in spatially confined systems.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Electron and recoil ion momentum imaging with a magneto-optically trapped target

A reaction microscope (ReMi) has been combined with a magneto-optical trap (MOT) for the kinematically complete investigation of atomic break-up processes. With the novel MOTReMi apparatus, the momentum vectors of the fragments of laser-cooled and state-prepared lithium atoms are measured in coincidence and over the full solid angle. The first successful implementation of a MOTReMi could be realized due to an optimized design of the present setup, a nonstandard operation of the MOT, and by employing a switching cycle with alternating measuring and trapping periods. The very low target temperature in the MOT (∼2 mK) allows for an excellent momentum resolution. Optical preparation of the target atoms in the excited Li 2{sup 2}P{sub 3/2} state was demonstrated providing an atomic polarization of close to 100%. While first experimental results were reported earlier, in this work, we focus on the technical description of the setup and its performance in commissioning experiments involving target ionization in 266 nm laser pulses and in collisions with projectile ions.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

State-selective dissociation dynamics of an oxygen molecular ion studied with single-harmonic pump and infrared-probe pulses

Laser-induced dissociation of a photoionized oxygen molecule is studied employing an extreme-ultraviolet-pump–near-infrared-probe (EUV-NIR pump-probe) technique. A combination of a narrow-band 11th harmonic pump centered at 17.3 eV and a moderate-intensity NIR probe restricts the dissociation dynamics to the pair of low-lying cationic states, a 4 Π u and f 4 Π g . The measured kinetic energies of the O + fragments reveal contributions from one-, two-, and three-photon dissociation pathways ( 1 ω , 2 ω , and 3 ω ) involving these two states. While the yields of the two- and three-photon channels initially rise and then decrease as a function of EUV-NIR delay, the yield of the single-photon pathway rises slower but keeps increasing over the whole delay range studied. Furthermore, this behavior reflects the evolving probability density of the ionic nuclear wave packet at the internuclear distances, where it can undergo resonant 3 ω and 1 ω transitions from the a 4 Π u to the f 4 Π g state of O 2 + .

74 ATOMIC AND MOLECULAR PHYSICS↗

PDC IC Weld Failure Evaluation and Resolution

During final preparations for start of the PDCF Inner Can (IC) qualification effort, welding was performed on an automated weld system known as the PICN. During the initial weld, using a pedigree canister and plug, a weld defect was observed. The defect resulted in a hole in the sidewall of the canister, and it was observed that the plug sidewall had not been consumed. This was a new type of failure not seen during development and production of legacy Bagless Transfer Cans (FB-Line/Hanford). Therefore, a team was assembled to determine the root cause and to determine if the process could be improved. After several brain storming sessions (MS and T, R and D Engineering, PDC Project), an evaluation matrix was established to direct this effort. The matrix identified numerous activities that could be taken and then prioritized those activities. This effort was limited by both time and resources (the number of canisters and plugs available for testing was limited). A discovery process was initiated to evaluate the Vendor's IC fabrication process relative to legacy processes. There were no significant findings, however, some information regarding forging/anneal processes could not be obtained. Evaluations were conducted to compare mechanical properties of the PDC canisters relative to the legacy canisters. Some differences were identified, but mechanical properties were determined to be consistent with legacy materials. A number of process changes were also evaluated. A heat treatment procedure was established that could reduce the magnetic characteristics to levels similar to the legacy materials. An in-situ arc annealing process was developed that resulted in improved weld characteristics for test articles. Also several tack welds configurations were addressed, it was found that increasing the number of tack welds (and changing the sequence) resulted in decreased can to plug gaps and a more stable weld for test articles. Incorporating all of the process improvements for the actual can welding process, however, did not result in an improved weld geometry. Several possibilities for the lack of positive response exist, some of which are that (1) an insufficient number of test articles were welded under prototypic conditions, (2) the process was not optimized so that significant improvements were observable over the "noise", and (3) the in-situ arc anneal closed the gap down too much so the can was unable to exhaust pressure ahead of the weld. Several operational and mechanical improvements were identified. The weld clamps were changed to a design consistent with those used in the legacy operations. A helium puff operation was eliminated; it is believed that this operation was the cause of the original weld defect. Also, timing of plug mast movement was found to correspond with weld irregularities. The timing of the movement was changed to occur during weld head travel between tacks. In the end a three sequential tack weld process followed by a pulse weld at the same current and travel speed as was used for the legacy processes was suggested for use during the IC qualification effort. Relative to legacy welds, the PDC IC weld demonstrates greater fluctuation in the region of the weld located between tack welds. However, canister weld response (canister to canister) is consistent and with the aid of the optical mapping system (for targeting the cut position) is considered adequate. DR measurements and METs show the PDC IC welds to have sufficient ligament length to ensure adequate canister pressure/impact capacity and to ensure adequate stub function. The PDC welding process has not been optimized as a result of this effort. Differences remain between the legacy BTC welds and the PDC IC weld, but these differences are not sufficient to prevent resumption of the current PDC IC qualification effort. During the PDC IC qualification effort, a total of 17 cans will be welded and a variety of tests/inspections will be performed. The extensive data collected during that qualification effort should be of a sufficient population to determine if additional weld process optimization is necessary prior to production release.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Optimization of current waveform tailoring for magnetically driven isentropic compression experiments

The Thor pulsed power generator is being developed at Sandia National Laboratories. The design consists of up to 288 decoupled and transit time isolated capacitor-switch units, called “bricks,” that can be individually triggered to achieve a high degree of pulse tailoring for magnetically driven isentropic compression experiments (ICE) [D. B. Reisman et al., Phys. Rev. Spec. Top.–Accel. Beams 18, 090401 (2015)]. The connecting transmission lines are impedance matched to the bricks, allowing the capacitor energy to be efficiently delivered to an ICE strip-line load with peak pressures of over 100 GPa. Thor will drive experiments to explore equation of state, material strength, and phase transition properties of a wide variety of materials. We present an optimization process for producing tailored current pulses, a requirement for many material studies, on the Thor generator. This technique, which is unique to the novel “current-adder” architecture used by Thor, entirely avoids the iterative use of complex circuit models to converge to the desired electrical pulse. We begin with magnetohydrodynamic simulations for a given material to determine its time dependent pressure and thus the desired strip-line load current and voltage. Because the bricks are connected to a central power flow section through transit-time isolated coaxial cables of constant impedance, the brick forward-going pulses are independent of each other. We observe that the desired equivalent forward-going current driving the pulse must be equal to the sum of the individual brick forward-going currents. We find a set of optimal brick delay times by requiring that the L{sub 2} norm of the difference between the brick-sum current and the desired forward-going current be a minimum. We describe the optimization procedure for the Thor design and show results for various materials of interest.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Status of the Mu2e experiment

The Mu2e experiment at Fermilab searches for the coherent, neutrino-less conversion of a μ − to e − in the Coulomb field of Al nuclei, that represents one of the cleanest Charged Lepton Flavor Violating (CLFV) processes for exploring Beyond the Standard Model (BSM) physics. Mu2e aims to improve previous sensitivity by four orders of magnitude, with a distinctive signature provided by identifying mono-energetic electrons with energy slightly below the muon rest mass. To reach this goal, the experiment will use the highest intensity pulsed muon beam in the world, with up to 6 × 1 0 9 stopped muons/sec. This is achieved using the Fermilab proton beam and the design and realization of a unique 25 m long superconducting solenoidal system. The high beam intensity relies upon minimizing beam losses in the slow extraction region, indicating an opportunity of using bent crystals for shadowing. A high-resolution straw tracker and a fast CsI crystal calorimeter identify the conversion electron. Both detectors are inserted behind the Stopping Target in the last solenoid section. A Cosmic Ray Veto covers a large part of the solenoids to suppress background produced by cosmic rays. In this paper, we report the details of the experimental layout, the construction status of the magnetic system and detectors, and a short description of the simulation and realization of the bent crystals. Performing crystal channeling in front of the first slow extraction septa will allow beam shadowing and largely reduce beam losses. •Charge Lepton Flavor Violation processes: μ − → e − conversion.•Large Superconducting Solenoid system.•High-Intensity beams•High precision detectors.•Crystal channeling.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Recent Advances in Analytical Electron Microscopy for Irradiated Materials

Analytical electron microscopy (AEM) in the scanning transmission electron microscope (STEM) has long been a staple of post-irradiation examination (PIE) and materials development campaigns. Recently, new advances in both STEM hardware and post-processing data-analysis software, along with ancillary advances such as in focused ion beam (FIB) sample preparation, has led to exciting advances in the quantity and quality of data that can be obtained. This talk will summarize recent experiments performed at Oak Ridge National Laboratory (ORNL), especially work on neutron-irradiated materials and fuels taking advantage of a newly-installed latest-generation AEM tool in the ORNL irradiated materials laboratories. ORNL installed a new FEI Talos F200X microscope, a 200 keV, high-brightness Schottky emission AEM system optimized for high-speed, high-efficiency X-ray mapping experiments. The F200X features the FEI 'SuperX' four-sector silicon drift detector (SDD) X-ray detector, which provides 0.9 sr solid angle of collection. By combining the high-brightness electron source, latest-generation electron optics, and fast computers and pulse processors, X-ray mapping speed is increased by a factor of 50-100 x compared to the previous-generation instruments. In addition to improvements in hardware, data mining via multivariate statistical analysis (MVSA) allows for maximum insight to the data obtained from the new hardware. MVSA data mining of the X-ray maps allows, for instance, unbiased computational identification of the phases present, and discovery of small phases or precipitates not expected by the human analyst. This talk will present examples of experiments performed using the most modern AEM tools and software. Silicon carbide is a major candidate for next-generation nuclear applications. Nano-infiltration by transient eutectic (NITE) SiC requires low sintering temperatures. X-ray mapping of the NITE structure find pockets of different oxides, such as Zr-Y-oxide, Y-Al-oxide, and yttria. MVSA data mining finds the regions where different oxides are present and indicates that Y additions preferentially wet grain boundaries, where Zr additions are preferentially concentrated at grain triple points. SiC coatings from AGR-I experiment TRISO particles were found to contain significant quantities of fission products (e.g., Pd) as well as actinides (U, Pu). MVSA data mining found complex precipitates and grain boundary films of the fission products and actinides deep (∼several microns) into the SiC layer. Advanced AEM methods, combined with MVSA data mining, makes possible both rapid and detailed PIE. Ferritic alloys, such as accident-tolerant FeCrAl grades, benefit greatly from advanced AEM examination. Neutron-irradiated FeCrAl precipitates the detrimental Cr-rich α' phase. Because the SuperX SDD system has four detectors, it is possible to obtain high X-ray count rates even on a highly tilted specimen, as might be needed to obtain STEM images of dislocation loops. Results on neutron-irradiated FeCrAl indicates that α' size and number density can be obtained by AEM, and MVSA results determine that minor elements (such as Si) has complex radiation-induced segregation behavior at grain boundaries. We have also developed and validated computer models of the AEM experiment, allowing different microstructures' X-ray map results to be simulated for different STEM instruments. This allows X-ray mapping to be more quantitative, such as by estimating what size nanoclusters in an oxide-dispersion strengthened steel would be visible or invisible in STEM. In summary, new advanced AEM technology provides a major leap forward in experiments possible in PIE of irradiated materials. (authors)

36 MATERIALS SCIENCE↗

The Mu2e Experiment

The Mu2e experiment will search for the charged-lepton flavor violating (CLFV) neutrino-less conversion of a negative muon into an electron in the field of a nucleus. The conversion process results in a monochromatic electron with an energy of 104.97 MeV, slightly below the muon rest mass. The goal of the experiment is to improve the previous upper limit by four orders of magnitude and reach a SES (single event sensitivity) of $3 \times 10^{-17}$ on the conversion rate, a 90% CL of $8 \times 10^{-17}$, and a $5\sigma$ discovery reach at $2 \times 10^{-16}$. The experiment will use an intense pulsed negative muon beam. The pulsed beam is essential to reducing backgrounds. The other essential element is a sophisticated magnetic system composed of three consecutive solenoids that form the muon beam. Mu2e will use an aluminum target and examine $\sim10^{18}$ stopped muons in three years of running. The Mu2e experiment is under design and construction at the Fermilab Muon Campus. The experiment will begin operations in 2022 and will require about three years of data-taking. Upgrades to other materials than aluminum are already being planned. This article is written specifically for younger researchers to bridge the gap between conference presentations and detailed design reports, and examines issues not covered in the former without the details of the latter.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A Quick Overview of the Extended Feynman Project

The low natural background rates and the penetrating nature of neutron radiation makes neutron detection a good method for quantifying and accounting for large amounts of special nuclear material capable of neutron induced fission and fission chains. Fission is one of the few natural processes that produces time-correlated neutrons, the others are spallation-type processes (e.g. (n,Xn), cosmic induced background, etc) which have low but measurable rates in common terrestrial material. The high rates of most transuranic spontaneous fission sources of even a gram or less usually swamp any cosmic induced background rate but even Kilogram quantities of natural uranium produce neutrons only on the same order as that of the cosmic generated background flux. However the primary characteristic of special nuclear material is its ability to fission and to support fission chains through neutron induced fission. This means that neutrons produced from fission are not produced randomly singly but rather in time-correlated bursts. Almost from the beginning of the atomic age, the measurement of time-correlated neutrons has been used to detect and quantify fission and fission processes. Feynman himself proposed a method, the grandfather of what is used today, to compare correlation rates of neutron flux in a fixed time to that which would be expected of a random neutron source. The larger variance (broader distribution) as compared to a random distribution is a tell-tale sign of correlated production and commonly used as signature of fission and more importantly fission chains, the broader the distribution (and its departure from a random distribution) the higher the multiplication. Feynman’s original method was used to determine the criticality of the first reactor and other critical or near critical systems. We at LLNL have been developing this concept over the past decade and a half and have employed it for the detection and assessment of nuclear materials. Our method for doing this involved generating a theoretical prediction of what we might expect to see, given a neutron source (spontaneous fission with a nubar, or alpha-n) and a possibly multiplying material (Plutonium or Uranium) and comparing it to a measured result and deducing from this what it is we are measuring. We first developed these methods for portable (low efficiency) thermal neutron detectors that were used predominantly for emergency response situations and we have applied some of these techniques with thermal neutron detectors to arms control verification and authentication, for example verifying that there are multiplying quantities of plutonium in an unknown object. In recent years we have been exploring the use of fast neutrons using liquid scintillator cells with Pulse Shape Discrimination (PSD) and in this project we developing both the theory of fast particle production from fission and fission chains and the use of fast particle detection methods primarily for arms control verification and authentication, but for other uses. We have found that fast detection has many advantages, primarily because the speed of the detection (nanoseconds) preserves the original time scale of the particles produced by fission (and more importantly from induced fission) but also because the fast time scales allow for considering much shorter measurement times (binning) that greatly reduce the pollution of random correlations.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Tracking reaction dynamics in solution by pump–probe X-ray absorption spectroscopy and X-ray liquidography (solution scattering)

Characterization of transient molecular structures formed during chemical and biological processes is essential for understanding their mechanisms and functions. Over the last decade, time-resolved X-ray liquidography (TRXL) and time-resolved X-ray absorption spectroscopy (TRXAS) have emerged as powerful techniques for molecular and electronic structural analysis of photoinduced reactions in the solution phase. Both techniques make use of a pump–probe scheme that consists of (1) an optical pump pulse to initiate a photoinduced process and (2) an X-ray probe pulse to monitor changes in the molecular structure as a function of time delay between pump and probe pulses. TRXL is sensitive to changes in the global molecular structure and therefore can be used to elucidate structural changes of reacting solute molecules as well as the collective response of solvent molecules. On the other hand, TRXAS can be used to probe changes in both local geometrical and electronic structures of specific X-ray-absorbing atoms due to the element-specific nature of core-level transitions. These techniques are complementary to each other and a combination of the two methods will enhance the capability of accurately obtaining structural changes induced by photoexcitation. Here we review the principles of TRXL and TRXAS and present recent application examples of the two methods for studying chemical and biological processes in solution. Furthermore, we briefly discuss the prospect of using X-ray free electron lasers for the two techniques, which will allow us to keep track of structural dynamics on femtosecond time scales in various solution-phase molecular reactions.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Pixelated plastic scintillator array manufacturing using fast-, photo-curable resin

Pixelated plastic scintillator arrays can serve as high efficiency and high resolution neutron imaging detectors. Manufacturing these arrays is intensive in both time and labor. This article presents a fabrication method based on additive manufacturing for two-dimensional plastic organic scintillator arrays using a custom-built automated assembly machine and a custom photocurable resin that has significant non-aromatic acrylate oligomer content. The process involves two main stages: fully autonomous production of one-dimensional layered arrays, followed by semi-autonomous cutting and stacking to form two-dimensional pixel arrays. One-dimensional arrays were manufactured at a rate of around 4 layers per hour with minimal defects and tight dimensional tolerances, while two-dimensional arrays up to 7 x 7 pixels and 70 mm in length were completed in approximately 3.5 hours. Final arrays exhibited dimensional deviations of less than 0.5 mm. Two-dimensional arrays read out by a multi-anode photomultiplier tube demonstrated per-pixel position resolution and pulse-shape discrimination, enabling gamma–neutron interaction separation in mixed radiation environments.

36 MATERIALS SCIENCE↗

Determination of the deuterium-tritium branching ratio based on inertial confinement fusion implosions

The deuterium-tritium (D-T) γ-to-neutron branching ratio [ 3 H(𝑑,γ) 5 He/ 3 H(d,n) 4 He] was determined under inertial confinement fusion (ICF) conditions, where the center-of-mass energy of 14–24 keV is lower than that in previous accelerator-based experiments. A D-T branching ratio value of (4.2 ± 2.0) × 10 −5 was determined by averaging the results of two methods: (1) a direct measurement of ICF D-T γ-ray and neutron emissions using absolutely calibrated detectors, and (2) a separate cross-calibration against the D- 3 He γ-to-proton branching ratio [ 3 He(𝑑,γ) 5 Li/ 3 He(d,p) 4 He]. Neutron-induced backgrounds were significantly reduced as compared to traditional beam-target accelerator-based experiments due to the short pulse nature of ICF implosions and the use of gas Cherenkov γ-ray detectors with fast temporal responses and inherent energy thresholds. These measurements of the D-T branching ratio in an ICF environment test several theoretical assumptions about the nature of 𝐴 = 5 systems, including the dominance of the 3/2 + resonance at low energies, the presence of the broad first excited state of 5 He in the spectra, and the charge-symmetric nature of the capture processes in the mirror systems 5 He and 5 Li.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Establishing nonlinearity thresholds with ultraintense X-ray pulses

X-ray techniques have evolved over decades to become highly refined tools for a broad range of investigations. Importantly, these approaches rely on X-ray measurements that depend linearly on the number of incident X-ray photons. The advent of X-ray free electron lasers (XFELs) is opening the ability to reach extremely high photon numbers within ultrashort X-ray pulse durations and is leading to a paradigm shift in our ability to explore nonlinear X-ray signals. However, the enormous increase in X-ray peak power is a double-edged sword with new and exciting methods being developed but at the same time well-established techniques proving unreliable. Consequently, accurate knowledge about the threshold for nonlinear X-ray signals is essential. Here in this paper we report an X-ray spectroscopic study that reveals important details on the thresholds for nonlinear X-ray interactions. By varying both the incident X-ray intensity and photon energy, we establish the regimes at which the simplest nonlinear process, two-photon X-ray absorption (TPA), can be observed. From these measurements we can extract the probability of this process as a function of photon energy and confirm both the nature and sub-femtosecond lifetime of the virtual intermediate electronic state.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Method for Calculating Delayed Gamma-Ray Response in the ACRR Central Cavity and FREC-II Cavity Using MCNP

This document presents the process for a new method developed for the characterization of the delayed gamma-ray radiation fields in pulse reactors like the Annular Core Research Reactor (ACRR) and the Fueled Ring External Cavity (FREC-II). The environments used to test this method in the ACRR were FF, LB44, PLG and CdPoly, and the environments used in the FREC-II were FF with rods-down, FF with rods-up, CdPoly with rods-down and CdPoly with rods-up. All environment configurations used the same fission product gamma-ray source energy spectrum. This method required the fission sites located in the MCNP KCODE source tapes. A FORTRAN script was written to translate and extract the coordinates for the fission sites. The 10K fission sites were then input it into an MCNP SOURCE mode script. Using a MATLAB script, a parametric analysis was done, and it helped determine that 10K fission sites are an appropriate number of coordinates to converge to the correct answer. The method gave excellent results and was tested in the ACRR, FREC-II and White Sands Missile Range (WSMR). This method can be applied to other pulse research reactors as well.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Two-dimensional heteronuclear single quantum coherence (HSQC) NMR spectra of lignin isolated from field grown transgenic poplar

Here we present a curated dataset of a series of two-dimensional heteronuclear single quantum coherence (HSQC) nuclear magnetic resonance (NMR) spectra of lignin isolated from a field grown transgenic poplar engineered with a monolignol 4-O-methyltransferase (MOMT4). The poplar was collected from a 2-year-old rotation trees within a three-year field trial experiment. The poplar was Soxhlet-extracted with toluene/ethanol and the extractives-free poplar was then ball-milled in a Retsch PM100 planetary ball mill using a porcelain jar with ceramic balls at 600 rpm for 2 h (in 5 min on and 5 min off cycles to avoid excessive sample heating). The ball-milled materials were then subjected to enzymatic hydrolysis for 48 h followed by centrifugation and washing with deionized water. The solid residue was extracted twice with 96:4 (v/v) 1,4-dioxane/water mixture at room temperature overnight. The extracts were combined, rotary evaporated, and freeze-dried to recover the lignin. The dry lignin samples were dissolved in deuterated dimethyl sulfoxide for NMR experiments. 13C–1H HSQC experiments were performed in a Bruker Avance III HD 500 MHz NMR spectrometer operating at a frequency of 125.12 MHz for the 13C nucleus using a standard Bruker pulse sequence (hsqcetgpsisp2.2) on a Prodigy platform cryoprobe. The NMR spectra were acquired under the following acquisition conditions: 220 ppm spectral width in F1 (13C) dimension with 256 data points and 12 ppm spectral width in F2 (1H) dimension with 1024 data points, a 90° pulse, a one bond C–H coupling constant of 145 Hz, a 1.0 s pulse delay, and 64 scans. All the data was processed using the Bruker’s TopSpin 3.6 software. The NMR spectra provides structural characteristics information about lignin in field grown transgenic MOMT4 poplar. Additional meta data is embedded in the raw spectra figures.

Lignin structure, HSQC, poplar, field trial, MOMT4↗